Article

Evaluating the Contamination by Indoor Dust in Dubai

1
College of Natural and Health Sciences, Zayed University, Abu Dhabi P.O. Box 144534, United Arab Emirates
2
Department of Civil Engineering, Transilvania University of Brașov, 5 Turnului Str., 900152 Brasov, Romania
3
College of Arts and Sciences, Fort Valley State University, Fort Valley, GA 31030, USA
*
Author to whom correspondence should be addressed.
Toxics 2023, 11(11), 933; https://doi.org/10.3390/toxics11110933
Submission received: 29 October 2023 / Revised: 13 November 2023 / Accepted: 14 November 2023 / Published: 17 November 2023

Abstract

:
Nowadays, people spend most of their time indoors. Despite constantly cleaning these spaces, dust apparition cannot be avoided. Since dust can contain chemical elements that negatively impact people’s health, we propose the analysis of the metals from the indoor dust component collected in different locations in Dubai, UAE. Multivariate statistics (correlation matrix, clustering) and quality indicators (QI)—Igeo, PI, EF, PLI, Nemerow—were used to assess the contamination level with different metals in the dust. We proposed two new QIs (CPI and AQI) and compared the results with those provided by the most used indices—PLI and Nemerow. It is shown that high concentrations of some elements (Ca in this case) can significantly increase the values of the Nemerow index, CPI, and AQI. In contrast, the existence of low concentrations leads to the decrement of the PLI.

1. Introduction

Indoor dust is the settled particulate matter (PM) found on carpets, floors, surfaces, and other objects in an indoor space. Among other pollutants from indoor dust, heavy metals require extensive research due to their non-degradable properties, high toxicity, and adverse effects on humans [1,2]. The United States Environmental Protection Agency (USEPA) has raised the alarm about indoor air quality, considering it a significant concern because it tends to be more polluted than outdoor air. This concern has grown because people spend a significant portion of their time indoors, encompassing homes, workplaces, schools, public spaces like shops, restaurants, and vehicles, amounting to up to 90% of their daily activities [3]. Children, who spend most of their day at home, are particularly vulnerable to environmental stressors because their breathing zone is close to the floor, where residential dust tends to collect, exposing them to potential health risks [4,5,6].
Carbon dioxide, volatile organic compounds, biocontaminants, fungi, bacteria, and particulate matters are among the indoor air pollutants with damaging potential to human health listed by the European Federation of Allergy and Airway Diseases Patient Associations in their document [7]. Dust intake rates for children are estimated to be between 30 and 140 mg/day, whereas adults consume 2–30 mg/day [8,9].
According to [10,11], indoor dust can be described as tiny particles (≤100 μm) that settle in indoor spaces. These particles can come from various sources situated inside and outside the building. Particles with diameters smaller than 10 μm (PM10) can be inhaled, the coarse fractions being retained in the upper airways, and those particles with diameters less than 2.5 μm can reach the pulmonary system or enter the blood [12]. Particles with diameters from 1 µm to 20 µm are responsible for the apparition of asthma [13]. Tsubata et al. [14] indicate that dust particles with diameters less than 11 µm contain up to 90% of allergens.
Research has indicated that indoor dust is a transporter for inorganic and organic contaminants, including heavy metals, pesticides, polychlorobiphenyls, and polycyclic aromatic hydrocarbons [5,6,15,16,17]. Indoor dust is a heterogeneous combination of particles that includes synthetic and natural fibers, hair, deposited atmospheric PM, biologically derived material (pollen, molds, bacteria, germs, animal fur, and dander), ash, skin particles, soot, and building and consumer product components [18]. Indoor dust typically contains about 35% outdoor soil, but this can vary widely based on factors like pets, shoe-wearing habits, and specific indoor settings. Indoor dust varies in organic content, typically ranging from 5% to 40%. Finer particles contain more organics, which are vital for absorbing pollutants. The fibrous particle content ranges from 9% to 89%, influenced by room type, furniture, and pet presence [19,20].
Pollutants enter the human body by inhalation, ingestion, and dermal contact [6,21,22,23,24]. According to [25], when inhaled, these toxic metals in dust can inflame, sensitize, and even scar the lungs and tissues because they are ubiquitous in the environment. Additionally, exposure to these metals may result in gastrointestinal issues, reproductive system problems, and nervous system disorders. Excessive exposure to Pb, Cd, Zn, and Cu is associated with the risk of cancer [26,27]. In this article, we analyze only the toxic metal found in indoor dust, whereas the dust microbiomes and metatranscriptomes have been studied in [28].
Bio-accessibility of heavy metals in indoor dust has been observed by physiologically based extraction tests or simplified bio-accessibility extraction tests based on the rationale that incidental oral ingestion is the main exposure pathway by which humans take in contaminants in indoor dust, especially for children [29,30,31].
Indoor air pollution poses a significant global health threat, contributing to around 4.5 million annual deaths worldwide. This pollution is responsible for a range of health issues, including pneumonia (12%), strokes (34%), ischemic heart diseases (26%), chronic obstructive pulmonary diseases (22%), and lung cancer (6%) [32,33]. Therefore, research on indoor air quality concluded that correct ventilation and proper cleaning [34,35] are necessary to avoid such health damage.
The International Agency for Research on Cancer (IARC) has classified Al, Co, Fe, Ni, and Zn as non-carcinogenic elements, whereas arsenic As, Cu, Cd, Cr, and Pb are classified as both carcinogenic and non-carcinogenic elements. The U.S. Environmental Protection Agency classified Cu, Cr, Ni, Zn, Cd, Mn, and Pb as environmental priority pollutants [36]. Moreover, it was shown that Cr, Cu, Ni, Zn, and Fe promote the exchange of electrons [34] and help the apparition of reactive oxygen species in the lungs [37].
On one hand, Cu is a micronutrient, a catalyzer of redox reactions, essential for the organism functioning. On the other hand, released in the atmosphere from anthropic (burning fossil fuel, solid waste management) and natural sources, it can attach to particulate matter and is transported long distances from its source [38].
Heavy metals like As, Cd, Cr, and Pb, which are widespread environmental pollutants, can cause health issues, including cancers, respiratory problems, cardiovascular diseases, nerve damage, and slow growth development [39,40,41,42].
Different particulate matter can also contain other elements like Ca, Li, and K transported by the wind, issued from the lithology of the place being studied.
This article presents the analysis of indoor settled dust in Dubai, UAE, which holds significant importance since Dubai’s rapid urban development and construction activities are closely linked to indoor dust accumulation. Although studies on dust transportation and outdoor pollution (particularly with heavy metals) in different emirates from the UAE have been carried out [43,44,45,46,47], indoor pollution was less analyzed [28,48,49,50], with the emphasis on gaseous pollutants. Therefore, in this study, the composition of indoor settled dust from 20 important locations across Dubai is investigated using a complex approach involving a multivariate statistical analysis combined with different indices, two newly proposed here. It is shown that a correct conclusion on contamination cannot be drawn from a single index computation but from a combination of such indices, given that some elements present in high concentrations in the samples can have a significant influence on the classification. Moreover, comparisons of the clustering based on the row data and the quality indicators may highlight the differences between the sites where the samples were collected.

2. Materials and Methods

2.1. Data Series

Dubai, located in the United Arab Emirates (UAE) is a remarkable city known for its unique blend of modernity and tradition. Situated on the Southeastern coast of the Arabian Peninsula (Figure 1), Dubai is one of the most prominent global cities, attracting tourists and business professionals from all over the world. It is bordered by the emirate of Sharjah to its north, while Abu Dhabi, the UAE’s capital, lies to the south. The climate of the study area is characteristic of the Arabian Peninsula, with hot and arid conditions prevailing throughout the year. Summers are exceedingly hot, with temperatures often exceeding 40 °C (104 °F). The city receives limited rainfall, and as a result, Dubai’s terrain is primarily desert, characterized by rolling dunes and sparse vegetation.

2.2. Sampling

Indoor-settled dust samples were collected using Dyson filters from twenty different locations in Dubai Emirates (Figure 1) including residential areas (Al Simmak Street, Bijada Blvd Street, Tulip Street), near heavy traffic junctions (Sheikh Zayed Highway), sports facilities (Sports City, Victory Heights), touristic areas (bars, restaurants), near water bodies (Dubai Marina) and commercial areas (markets, beauty lounges, butchers’ shops). Additionally, samples were also taken from specific buildings from Al Mustaqbal Street, Sheikh Mohammed Bin Rashid Blvd, a roundabout in Motor City, and near metro stations, offering a diverse range of environmental sources for analysis. The buildings’ characteristics differed, varying from the location, building materials, purpose, and maintenance. The dust samples were collected from undisturbed surfaces. Before sampling, the sites’ environmental conditions—temperature and humidity—were measured using a Graywolf Indoor Air Quality Meter (GrayWolf Sensing Solutions, LLC, Shelton, CT, USA) [51]. The measurements were performed when the atmospheric conditions were stable. The temperature inside was between 19 and 20 °C, and the relative humidity (RH%) was in the range of 40–45%. The coordinates of the observation sites were recorded using a South S750 Handheld GPS meter (Guangzhou, China) [52].
A Dyson V15 Detect vacuum machine with two heads (Gurugram, India) (separately collecting dust particles from rugs/carpets with a fluffy brush-bar and filter, and hard floors with a built-in laser light to observe the incoming material from the cleaning surface) was utilized. The Dyson vacuum has a HEPA post-motor filter that can trap particles with dimensions at least of 0.1 microns. Moreover, the dust particles are continuously counted and sized by a piezo-sensor [53].
A representative sampling strategy was adopted to collect the samples, which were transferred into re-sealable plastic bags by gently sweeping with fingers wearing powder-free nitrile gloves. They were safely packed and moved to the laboratory, where they were screened to remove any visible hair, soil, and grit. The samples were then air-dried for 48 h to avoid moisture in a well-protected area. All the results were reported based on dry weight.

2.3. Reagents, Standards and Laboratory Ware

In this research, all experiments were conducted using high-quality analytical reagent (AR) grade chemicals. We sourced the reference standard, check standard, and reagents from Sigma Aldrich (St. Louis, MO, USA). To create a 1:1 acid mixture, concentrated nitric acid (69% v/v) and hydrochloric acid (37% v/v) were combined. The water purity was ensured by using ultra-pure water with a chemical resistivity of 18.2 MΩ·cm from the Merck Millipore( Burlington, MA, USA) water purification system. For sample oxidation, 30% hydrogen peroxide was utilized. The equipment quality was maintained by using Class-A grade glassware for all the analyses. To eliminate potential contaminants, all items of glassware and plasticware were cleaned by washing them 5–6 times with ultra-pure water, and rinsing with 10% nitric acid, then drying them with an air drier. Later, sample digestion was carried out using the Mars-6 system from CEM in Matthews, NC, USA. Finally, ICP-OES analysis was conducted using OH, USA’s Perkin Elmer Avio 200 system.
The sample digestion process followed the USEPA 3050B procedure (Washington, DC, USA) [54]. Initially, 0.2 g of each sample was weighed and placed into Teflon vessels for microwave-assisted digestion. Subsequently, 10 mL of a 1:1 HCl: HNO3 solution was added into the digestion vessel, thoroughly mixed with the sample slurry, and subjected to microwave digestion at 95 °C for 5 min. After digestion, the slurry was allowed to cool, and 5 mL of concentrated HNO3 was added. This mixture was then heated and refluxed at 95 °C for 5 min, followed by cooling and carefully adding 10% H2O2 for oxidation. The resulting solutions were transferred into 100 mL volumetric flasks, adjusted to the markup with water, and subsequently filtered using Whatman 41 filters (Maidstone, UK). The filtered solutions were subsequently subjected to analysis for heavy metals using an ICP-OES system, with eight replicate analyses conducted for each sample.
Quality control and assurance protocols were carefully observed throughout the sample preparation and analysis processes, encompassing laboratory blanks, check standards, and standard spiked samples. Laboratory blanks were prepared utilizing the same reagents employed for digestion but excluding the addition of dust samples. For all metals, the laboratory blank values were under the concentrations of metals in the target samples. The method detection limit (MDL) was calculated using the equation:
MDL = X + 2.896 × SD
where X is the mean, SD is the standard deviation of blanks, and 2.896 is the value of the Student statistics at the significance level of 99%, and eight degrees of freedom. This equation has been used according to [55,56] because all the method blanks give either positive or negative numerical results. The MDL values ranged between 0.02 µg/kg (Cd) and 25.2 µg/kg (K). The metals recovery percentage (spiked and standard) was between 95% and 105%. The analytical precision for every metal of repeated analysis was determined by using the coefficient of variation, which was less than 3%.

2.4. Statistical Analysis

The first step in the analysis was the computation of the basic statistics—minimum (min), maximum (max), mean, median, standard deviation (std.dev.), coefficient of variation (CV), skewness coefficient, and kurtosis. The correlation matrix was determined to assess the correlation between the chemical elements in the dust.
After normalizing the data series, the set was submitted to clustering to group the 20 series recorded at different sites according to their common properties. For a better classification, the k-means algorithm [57] and hierarchical clustering [58] were used to cross-validate the results. Before performing the algorithms, the elbow [59] and silhouette [60] methods were utilized to choose the optimum number of clusters, k.
Groups of series formed the output of the first technique, while that of the second one was a dendrogram that shows the series hierarchy and can be constructed by employing a certain distance, like the Euclidean one (utilized in this study). The degree of similarity between the elements in each group was estimated using different methods like “complete”, “average”, “ward.D2”, and “median”. The better-performing method was selected based on the highest value of the cophenetic correlation coefficient [61]. After clustering, bootstrapping was conducted to compute the average Jaccard measures, to ensure that the algorithm provided a good representation of the groups. A value of the Jaccard coefficient greater than 0.85 indicates a highly stable clustering, whereas one between 0.60 and 0.85 shows a stable grouping [62].
The next stage was to perform the Principal Component Analysis [63]. PCA is a multivariate statistical technique utilized for reducing the number of the observed parameters by replacing them with a smaller number of components, artificially created, called Principal Components (PC). The extracted PCs incorporate the highest part of the variance of raw parameters (usually above 80%) and are obtained as a linear combination of those parameters [64]. They can be considered independent factors that govern the development of a given process [65]. Among the criteria employed for the PC selection—Explained Variance Criterion [64,65], Catell Scree Plot [66], and Kaiser criterion [67]—the first two were utilized in this research.
The R 4.3.1 software (https://cran.r-project.org/, accessed on 15 October 2023) was the tool for performing the analysis.

2.5. Pollution Indices

To assess the pollution level or enrichment with the metals in the dust, the following indices were computed. They are:
For the metal i, I g e o is calculated using the formula [68,69,70]:
I g e o = l o g 2 ( C i / ( 1.5 C B i ) ) ,
where C i   is the concentration of the i-th element in the dust and C B i is the value of the i-th element in the background.
The pollution index of the j-th element is given by [68]:
P I j = C j / C B j .
Values of PI in the intervals less than 1, 1–2, 2–3, 3–5, and greater than 5, respectively, indicate the contamination absence, low, moderate, strong, and very strong pollution, respectively.
The enrichment factor with the j-th element,   E F j , is defined by [68,69,70]:
E F j = [ C j / L V s ] / [ C B j / L V b ]
where C j is the concentration of the element j in the sample, L V s is the concentration of the reference element (generally Al, Ca, or Fe) in the sample, C B j is the reference concentration of j-th element in the background, and L V b is the concentration of the reference element in the background.
The background values utilized here are those from [71]. Same information can be found in [72] for different regions of the world.
Based on the value of the EF factor—less than 2, between 2 and 5, in the interval 5–20, between 20 and 40, or greater than 40—different classes of pollution are defined as deficient to minimal, moderate, significant, very high, and extremely high, respectively.
Aggregated indices can be computed from the individual ones to assess the contamination with multiple elements at a specific location. Two known indices were computed. The first one is PLI, defined by [73]:
P L I = ( j = 1 n P I j ) 1 / n .
PIs of some elements (As, Ba, Co, Pb, in this case) are very low (of order 10−2), so they will artificially decrease the PLI value. Therefore, to have a correct evaluation of the contamination degree, the PIs corresponding to these elements were removed from the computation of the PLI, the resulting index, denoted by PLI_d, being also computed and compared with PLI.
The second one is the Nemerow index, calculated by [74]:
P I N e m = [ P I ¯ 2 + P I m a x 2 ] / 2
with
P I m a x = max ( P I 1 ,   ,   P I n )   and   P I ¯ = ( j = 1 n P I j ) / n .
Values less than 0.7, in the intervals 0.7–1, 1–2, 2–3, and higher than 3 are indicative of the absence of pollution, warning level, slight contamination, moderate pollution, and heavy contamination, respectively.
Two new indices are proposed, analogous to those used in water pollution assessment [75,76]. The first one, called in the following Combined Pollution Index (CPI), is defined by the formula:
C P I = 1 n j = 1 n ( C j / C B j ) .
We propose to keep as reference values those for P I N e m .
The arithmetic weighted index is defined by:
A Q I = ( j = 1 n w j Q j ) / ( j = 1 n w j ) ,
with w j the weight associated with the quality index Q j of ith parameter,
Q j = 100 × C j / C B j ,
          w j = 1 C B j / ( j = 1 n 1 C B j ) .
The following classes are associated with the ranges (0–25)—unpolluted, (26–50)—warning level, (51–75)—slight pollution, (76–100)—moderate pollution, and (above 100)—heavy pollution.

3. Results and Discussion

Table 1 contains the basic statistics of the chemical elements series from the samples. The highest concentrations are those of Ca, K, Mg, Al, and Fe, and the lowest are those of Co, As, and Pb. Standard deviations (std.dev.) of most series of elements are high, indicating a high variation around the mean, but the variation coefficients are moderate. Only a few series present an accentuated skewness (Cr, Ba, Na, Mg), indicating a large variation range of the corresponding values.
The high concentrations of Cu, Mg, Fe, and Al in the dust might be explained by their existence in the natural rocks and anthropic activity. For example, there are 120 known occurrences of copper mineralization in the United Arab Emirates, situated in the mountainous region between Kalba and Dibba, or Wadi Hamm [77]. UAE is the seventh exporter of Mg in the world [78] and exported USD 53.6 M in iron ore in 2021 [79]. Moreover, it is the fifth aluminum-producing country in the world [80].
Studies indicate that indoor air quality is significantly affected by the outdoor air [81,82,83,84,85]. Kuo and Shen [83] found a similar increase in the concentrations of PM2.5 and PM10 in both indoor and outdoor air during a dust-storm event and interpreted the cause to be the extraction of outdoor air from their building’s ventilation system. The research of Ai and Mak [86] and Meier et al. [87] has shown that natural ventilation contributes to the deterioration of indoor air quality. Fisk [13] has found that the air in mechanically ventilated buildings enters from a small number of intakes so that the indoor air quality is significantly affected by the intakes’ neighboring sources situated outdoors. An extended review of the research on the correlation between indoor and outdoor air quality was performed in [88]. Therefore, in the case study, the high concentration of Mg, Fe, and Al from the indoor dust (highly correlated to that from outdoors), originates from the soil dust composition of a desert area, but one cannot ignore the contribution from industrial activities. The above-mentioned mining operations can introduce additional concentrations of minerals like Mg, Fe, and Al into the environment, and dust storms, frequent in the region, can transport these minerals over broader areas. To assess the minerals’ origin in the indoor dust, samples should be analyzed in future studies.
Figure 2 presents the correlation matrix. The colors closer to red indicate a higher positive correlation between elements, and those closer to dark blue show a higher negative correlation.
Table 2 contains the p-values associated with the correlations between the chemical elements in the dust samples. The p-values less than 0.05 indicate a correlation between the elements. The lower the p-value, the higher the correlation is. Significant correlations are between the pairs Co–Ni, Fe–Ni, Mn–Ni, Mn–Mg, Mn–Sr, Mn–Al, Mn–Cd, Zn–Mg, Zn–Ca, Co–Fe, Co–Mn, Co–Sr, Co–Al, Co–Cd, Fe–Mn, Fe–Mg, Fe–Sr, Fe–Al, Fe–Cd, etc. This means that significant correlations are found between the metals in the dust resulting mainly from industrial activities and transported for long distances by the wind.
The optimal number of clusters, k, determined by the elbow and silhouette (Figure 3) was two (Figure 3).
After bootstrapping, the calculated average Jaccard values were 0.983 and 0.980, and the corresponding instabilities were 0.005 and 0.014. So, the groups found are highly stable. The first cluster contains the samples collected mainly from Dubai downtown, Burj Khalifa, near crowded zones, and in the vicinity of sandy zones. The second one is formed mainly by locations situated near the seafront, in green zones, and residential areas. The sampling series from the first cluster mainly contains the highest Pb, Zn, and Co concentrations and the lowest concentrations of Ni, Mn, and Mg.
The clusters obtained by the k-means algorithm (k = 2) are presented in Figure 4a. The dissimilarities between the elements in two clusters, in the hierarchical clustering, were assessed by different methods, among which “average” best performed in terms of cophenetic correlation coefficient (which was the highest compared to those of “complete”, “average”, “ward.D2”, and “median” procedures). In this method, all pairwise dissimilarities between the elements in two clusters were computed, and the distance between clusters was calculated by averaging these dissimilarities.
After bootstrapping, the obtained average Jaccard values (instabilities) were 0.828 (0.146) and 0.826 (0.172), showing that the clusters are stable. The dendrogram resulting from the hierarchical clustering is displayed in Figure 4b. Comparing Figure 4a,b, one may observe that both methods provided the same clusters.
PCA found 17 PCs, corresponding to the same number of chemical elements. However, Table 3 provides the computation results of only five PCs, including the proportion of the variance explained by each component, the cumulative proportion, and the standard deviation. The first two (three) PCs explain 80.90% (89.5%) of the variance. So, PC1 explains more than two-thirds of the information provided by the 17 variables, whereas PC2 and PC3 explain, respectively, 11.53% and 8.58% of the total variance.
The cumulative proportion of PC1–PC3 is about 89.46% of the total variance. So, PC1–PC3 (or even only PC1 and PC2) can accurately represent the data set. The screen plot that reflects this information is shown in Figure 5a.
The PC score (factor loading) of each variable in a PC indicates the processes controlling the variability of the data [89]. The loading table (Figure 5b) shows that the first principal component has high positive values for Co and Na. The values for Mg, Cd, Ca, and Ni are negative. This suggests that sites with a component of Co and Na in the dust are in excess. In PC2, Ca, Cr, and Pb are in excess, while the negative contributions come from Na, As, K, and Al. The highest contributions on PC3 are of Pb, Cu, Zn, Cr, and Ni. Therefore, the main contributions are those of Cr, Cu, Zn, Pb, Ni, and As, resulting mainly from human activities (transportation and industry). The variables’ quality representation on the factors map (cos2 representation) is shown in Figure 6. The better the representation, the higher the cos2 is. So, the groups (Mn, Cd, Fe, and Ca), (Pb, Na, K, and Cr), and (Mn, Cd, Fe, and Ni) are, respectively, the best represented on the first three PCs. The variables’ contributions in different dimensions are also represented in Figure 7.
The highest absolute values on PC1 are represented in nuances of blue. They are Mn, Cd, Fe, and Ca. Note that Mn, Cd, and Sr are grouped, indicating their correlation. The same remark stands for Mg, Ni, and Fe. Co is negatively correlated with Fe and Al; the same remark for Na and Pb, etc.
The contamination levels with respect to the I g e o values from the literature and the degree of contamination at the studied sites are presented in Table 4. The elements with significant impacts at all sites are Fe, Mg, Ca, and K.
With respect to PI, no pollution with Cu, Ni, Pb, Co, Cr, Ba, Mn, Sr, As, or Cd was found. Low pollution with Zn was found at the sites 1, 4, 5, 7–12, 15, 18–20, Al—9, 17, and 20. Moderate pollution was that with Fe (at 7, 9, 17), Mg (at 17), and Al (at 1, 3, 7, 8, 10–16, 18). Strong pollution was noticed with Fe (at 1, 3, 5, 8, 10–16, 18–20), Mg (at 7–9, 11, 19, and 20), and Al (at 2 and 4–6). Very strong pollution was registered with Fe (at 2 and 4) and Mg (1–6, 10, 12–16, and 17). The PI for Na falls between 1 and 2, at sites 1, 5–7, and 18, and between 2 and 3 at 20. PIs for Ca and K are greater than 5 at all sites.
Based on the EF computed with respect to Al, moderate enrichment was seen for Fe (at sites 8, 9, and 19), with Mg (at 1, 2, 4, 6, 8–10, 12–16, and 18–20), and K (at 1–6 and 12–17), whereas significant enrichment was determined only with Mg at site 3, and K (at 7–11, and 18–20).
The EF calculated with respect to Ca shows that all the sites are in the same category of deficient to minimum enrichment. EF computed with respect to Ca indicates a moderate enrichment in K (at all sites but 6, 7, and 18) and Mg (at site 3). Significant enrichment in K was determined at sites 7 and 18 and in Ca at all sites.
PLI values are between 0.26 and 0.58, so less than 1, proving a variation between perfection (indicated by a value of 0) and baseline (shown by a value of 1). Since the PIs corresponding to Co, As, Cd, and Pb are under 0.03, they contribute to the decrease in PLI values. Removing these elements from computation, denoted by PLI_d, produced values from 0.60 to 1.61 (Figure 8). PLI_d is more than two times higher than PLI.
PLI_d indicates a variation between perfection and baseline (0 < PLI < 1) for sites 1, 8, 9, 16, 17, and 19, and there is a progressive deterioration of the air quality (1 < PLI < 1.61) for all sites but those already mentioned. Locations 2, 4, 6, 12, and 20 have the highest PLI and PLI_d, and so the biggest contamination, as shown in Figure 8. All but site 20 belong to the second cluster in Figure 4a.
Taking into account all PIs, the Nemerow pollution index obtained values between 18.02 and 45.56, indicating high contamination at all locations. Removing the PI for Ca, the values of the index, denoted P I N e m C a , varied in the interval 3.67–16.89. Notice the essential influence of the very high PIs on the values of the Nemerow index.
All values of the CPI index (Figure 8) were between 3.09 and 5.43, indicating heavy pollution.
Since Ca is an element that has mainly a natural origin, and we did not find essential evidence of another origin in the region, removing it from the CPI computation (and denoting the new index by CPI-Ca), the variation in CPI-Ca was in the interval 0.92–2.46. Therefore, the pollution level from site 17 is graded warning, locations 2, 3, 5, 6, 10, and 18 are moderately polluted, and the rest are slightly contaminated.
The P I N e m and CPI are influenced by the highest values of the ratio C j / C B j ,   in contrast with the PLI, whose values are more related to the elements’ lowest concentrations.
Computation of the AQI (Figure 9) taking into account all elements (case a) or without calcium (case b—AQI-Ca) resulted in (a) heavy pollution at all sites, respectively, and (b) slight pollution at site 17 and moderate contamination at sites 9, 16, 19. Three of these locations are situated in the same cluster from Figure 4a. The shapes of the CPI and AQI indices charts are similar. A significant decrement in their values is noticed when Ca is removed from computation.
As mentioned above, the PIs computed for four elements were under 0.01, and they were removed from the computation of the PLI, leading to obtaining PLI_d. For consistency, we removed these elements from the initial data set (let us denote it Set1), obtaining set S2 that contained only 13 series of elements. The same analysis as that presented above has been performed for Set2. We only summarize the findings:
The k-means algorithm and hierarchical clustering provided the same clusters and dendrogram as in Figure 4, indicating that the removed series does not have a significant importance to lead to a difference between the sites.
The Nemerow indices computed with Set2 are the same (up to the third decimal) as those computed using Set1, while the CPI and AQI have higher values for Set2.
The k-means algorithm performed on the series of indices obtained from Set2 provided the same clusters as in Figure 4a—see Figure 10a.
The hierarchical clustering performed on the series of indices obtained from Set2 provided a cluster containing the series 1, 7–9, 11, 17, 19, and 20 which are also in the left-hand-side cluster from Figure 4b.
Figure 11, the biplot obtained performing the PCA for Set2 indicates the positions of the sites in the first cluster from the dendrogram—all grouped at the left-hand side of the biplot, with negative components on PC2. A clear separation line (the red one) can be drawn between the two clusters. The locations from the first cluster are in tourist areas—Dubai Marina, Burj Khalifa, and Dubai Sport City. Site 16 is situated on Dubai Marina Promenade, near the water, in a restricted area for cars, a zone with the lowest recorded concentrations of the study metals. This particular situation is emphasized by its position on the biplot.
We should remember that, generally, the perfect superposition of the clusters determined by both methods is a particular situation given the various mathematical backgrounds on which the algorithms rely. In the case of homogenous sets, it is expected (which is not the case in this study).
Performing the algorithm to determine the clustering by elements, two clusters were obtained, one with only two elements As and Cd (when working with Set1), and Ca and K (when working with Set2). This situation pointed out the elements with the lowest and highest concentrations, respectively, the last ones requiring attention.

4. Conclusions

This article analyzed the degree of enrichment with metals of the dust collected indoors at different locations in Dubai, using multivariate statistics and pollution indices. The study fills a gap in the knowledge concerning indoor pollution due to dust in a region where frequent dust storms appear.
It was shown that the highest enrichment factors (for Ca, Cu, Mg, and Fe) are the consequence of the soil lithology and industrial activities (especially mining), dust being transported for long distances from the emission places during dust storms.
We proposed two new pollution indices—CPI and AWI—and used them for assessing the contamination at the observation places. We classified the sites based on the set formed by the PLI, CPI, AWI, and the Nemerow index and compared it with that built by row data series. It was found that two sites fall into different clusters resulting from these classifications.
Another finding that opens a research direction is using different groups of data sets for classifications in practical applications. It was shown that for the clusters built when eliminating the elements with the lowest concentrations (much under the warning limits) from the data set, the obtained classifications are more realistic.
Employing different clustering algorithms on the raw data series and the pollution indices series, and the use of stability criteria, are important for finding the most similar series in the data set (those that are found all the time together in the same cluster).
In a future study, we intend to present a methodology that will come to cross-validate the clustering findings, using supplementary selection criteria and decision trees.

Author Contributions

Conceptualization, Y.N. and A.B.; methodology, Y.N. and A.B.; software, A.B. and M.S.; validation, A.B. and F.H.; formal analysis, A.B. and M.S.; investigation, A.B. and M.S.; resources, Y.N. and A.B.; data curation, Y.N., A.B. and M.N.; writing—original draft preparation, Y.N., A.B. and M.S.; visualization, A.B. and M.N.; supervision, Y.N. and A.B.; project administration, Y.N. and A.B.; funding acquisition, Y.N. and A.B. All authors have read and agreed to the published version of the manuscript.

Funding

This project was funded by the Research Office, Zayed University, the United Arab Emirates (Project No. R 20115).

Data Availability Statement

Data will be available on request from the author.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Meza-Figueroa, D.; La O-Villanueva, M.D.; Parra, M.L.D. Heavy metal distribution in dust from elementary schools in Hermosillo, Sonora, Mexico. Atmos. Environ. 2007, 41, 276–288. [Google Scholar] [CrossRef]
  2. Darus, F.M.; Nasir, R.A.; Sumari, S.M.; Ismail, Z.S.; Omar, N.A. Heavy metals composition of indoor dust in nursery schools building. Procedia Soc. Behav. Sci. 2012, 38, 169–175. [Google Scholar] [CrossRef]
  3. Höppe, P.; Martinac, I. Indoor climate and air quality. Review of current and future topics in the field of ISB study group 10. Int. J. Biometeorol. 1998, 42, 1–7. [Google Scholar] [PubMed]
  4. Schweizer, C.; Edwards, R.D.; Bayer-Oglesby, L.; Gauderman, W.J.; Ilacqua, V.; Jantunen, M.J.; Lai, H.K.; Nieuwenhuijsen, M.; Kunzli, N. Indoor time microenvironment-activity patterns in seven regions of Europe. J. Expo. Sci. Environ. Epid. 2007, 17, 170–181. [Google Scholar] [CrossRef] [PubMed]
  5. Schwarze, P.E.; Ovrevik, J.; Lag, M.; Refsnes, M.; Nafstad, P.; Hetland, R.B.; Dybing, E. Particulate matter properties and health effects: Consistency of epidemiological and toxicological studies. Human Exper. Toxicol. 2006, 25, 559–579. [Google Scholar] [CrossRef] [PubMed]
  6. Tran, D.T.; Alleman, L.Y.; Coddeville, P.; Gallo, J.C. Elemental characterization and source identification of size resolved atmospheric particles in French classrooms. Atmos. Environ. 2012, 54, 250–259. [Google Scholar] [CrossRef]
  7. Franchi, M.; Carrer, P.; Kotzias, D.; Rameckers, E.M.A.L.; Seppänen, O.; van Bronswijk, J.E.M.H.; Viegi, G.; Towards Healthy Air in Dwellings in Europe. The THADE Report. Available online: https://ec.europa.eu/health/ph_projects/2001/pollution/fp_pollution_2001_frep_02.pdf (accessed on 15 October 2023).
  8. Al-Rajhi, M.A.; Seaward, M.R.D.; Al-Aamar, A.S. Metal levels in indoor and outdoor dust in Riyadh, Saudi Arabia. Environ. Int. 1996, 22, 315–324. [Google Scholar] [CrossRef]
  9. Exposure Factors Handbook: 2011 Edition (EPA/600/R-09/052F); United States Environmental Protection Agency: Washington, DC, USA, 2011.
  10. Wilson, R.; Jones-Otazo, H.A.; Petrovic, S.; Mitchell, I.; Bonvalot, Y.; Williams, D.; Richardson, G.M. Revisiting dust and soil ingestion rates based on hand-to-mouth transfer. Hum. Ecol. Risk Assess. 2013, 19, 158–188. [Google Scholar] [CrossRef]
  11. Rashed, M.N. Total and extractable heavy metals in indoor, outdoor and street dust from Aswan City, Egypt. Clean Soil Air Water 2008, 36, 850–857. [Google Scholar] [CrossRef]
  12. Fiordelisi, A.; Piscitelli, P.; Trimarco, B.; Coscioni, E.; Iaccarino, G.; Sorriento, D. The mechanisms of air pollution and particulate matter in cardiovascular diseases. Heart Fail. Rev. 2017, 22, 337–347. [Google Scholar] [CrossRef]
  13. Fisk, W.J. 10—Impact of ventilation and aircleaning on asthma. In Clearing the Air: Asthma and Indoor Air Exposure; National Academies Press: Washington, DC, USA, 2000. Available online: https://www.ncbi.nlm.nih.gov/books/NBK224478/ (accessed on 12 November 2023).
  14. Tsubata, R.; Sakaguchi, M.; Yoshizawa, S. Particle size of indoor airborne mite allergens (Der p 1 and Der f 1). Proc. Indoor Air’96 1996, 3, 155–160. [Google Scholar]
  15. Maertens, R.M.; Bailey, J.; White, P.A. The mutagenic hazards of settled house dust: A review. Mutat. Res. 2004, 567, 401–425. [Google Scholar] [CrossRef] [PubMed]
  16. Tong, T.Y.; Lam, K.C. Home sweet home? A case study of household dust contamination in Hong Kong. Sci. Total Environ. 2000, 256, 115–123. [Google Scholar] [CrossRef] [PubMed]
  17. Hassan, S.K.M. Metal concentrations and distribution in the household, stairs and entryway dust of some Egyptian homes. Atmos. Environ. 2012, 54, 207–215. [Google Scholar] [CrossRef]
  18. Praveena, S.M.; Abdul Mutalib, N.S.; Aris, A.Z. Determination of heavy metals in indoor dust from primary school (Sri Serdang, Malaysia): Estimation of the health risks. Environ. Forensics 2015, 16, 257–263. [Google Scholar] [CrossRef]
  19. Morawska, L.; Salthammer, T. Indoor Environment. Airborne Particles and Settled Dust; Wiley: Hoboken, NJ, USA, 2003. [Google Scholar]
  20. Lioy, P.J.; Freeman, N.C.G.; Millette, J.R. Dust: A metric for use in residential and building exposure assessment and source characterization. Environ. Health Perspect. 2002, 110, 969–983. [Google Scholar] [CrossRef]
  21. Kang, Y.; Cheung, K.C.; Wong, M.H. Mutagenicity, genotoxicity and carcinogenic risk assessment of indoor dust from three major cities around the Pearl River Delta. Environ. Int. 2011, 37, 637–643. [Google Scholar] [CrossRef] [PubMed]
  22. Popoola, O.E.; Bamgbose, O.; Okonkwo, O.J.; Arowolo, T.A.; Popoola, A.O.; Awofolu, O.R. Heavy metals content in classroom dust of some public primary schools in metropolitan Lagos, Nigeria. Res. J. Environ. Earth. Sci. 2012, 4, 460–465. [Google Scholar]
  23. Cao, S.; Duan, X.; Zhao, X.; Wang, B.; Ma, J.; Fan, D.; Sun, C.; He, B.; Wei, F.; Jiang, G. Health risk assessment of various metal(loid)s via multiple exposure pathways on children living near a typical lead-acid battery plant, China. Environ. Pollut. 2015, 200, 16–23. [Google Scholar] [CrossRef]
  24. Rout, T.K.; Masto, R.E.; Ram, L.C.; George, J.; Padhy, P.K. Assessment of human health risks from heavy metals in outdoor dust samples in a coal mining area. Environ. Geochem. Health 2015, 35, 347–356. [Google Scholar] [CrossRef]
  25. Gbadebo, A.M.; Bankole, O.D. Analysis of potentially toxic metals in airborne cement dust around Sagamu, Southwestern Nigeria. J. Appl. Sci. 2007, 7, 35–40. [Google Scholar] [CrossRef]
  26. Wu, G.; Kang, H.; Zhang, X.; Shao, H.; Chu, L.; Ruan, C. A critical review on the bio-removal of hazardous heavy metals from contaminated soils: Issues, progress, eco-environmental concerns and opportunities. J. Hazard. Mater. 2010, 174, 1–8. [Google Scholar] [CrossRef] [PubMed]
  27. Yousaf, B.; Liu, G.; Wang, R.; Imtiaz, M.; Rizwan, M.S.; Zia-ur-Rehman, M.; Qadir, A.; Si, Y. The importance of evaluating metal exposure and predicting human health risks in urban–periurban environments influenced by emerging industry. Chemosphere 2016, 150, 79–89. [Google Scholar] [CrossRef] [PubMed]
  28. Nazzal, Y.; Howari, F.M.; Yaslam, A.; Iqbal, J.; Maloukh, L.; Ambika, L.K.; Al-Taani, A.A.; Ali, I.; Othman, E.M.; Jamal, A.; et al. A Methodological Review of Tools That Assess Dust Microbiomes, Metatranscriptomes and the Particulate Chemistry of Indoor Dust. Atmosphere 2022, 13, 1276. [Google Scholar] [CrossRef]
  29. Chattopadhyay, G.; Lin, K.C.P.; Feitz, A.J. Household dust metal levels in the Sydney metropolitan area. Environ. Res. 2003, 93, 301–307. [Google Scholar] [CrossRef] [PubMed]
  30. Liu, Y.; Ma, J.; Yan, H.; Ren, Y.; Wang, B.; Lin, C.; Liu, X. Bioaccessibility and health risk assessment of arsenic in soil and indoor dust in rural and urban areas of Hubei province, China. Ecotox. Environ. Saf. 2016, 126, 14–22. [Google Scholar] [CrossRef]
  31. Rasmussen, P.E.; Beauchemin, S.; Chénier, M.; Levesque, C.; MacLean, L.C.; Marro, L.; Jones-Otazo, H.; Petrovic, S.; McDonald, L.T.; Gardner, H.D. Canadian house dust study: Lead bioaccessibility and speciation. Environ. Sci. Technol. 2011, 45, 4959–4965. [Google Scholar] [CrossRef]
  32. Household Air Pollution. Available online: https://www.who.int/news-room/fact-sheets/detail/household-air-pollution-and-health (accessed on 27 October 2023).
  33. Indoor Air Pollution. Available online: https://www.who.int/news-room/questions-and-answers/item/air-pollution-indoor-air-pollution (accessed on 27 October 2023).
  34. Popovici, B.; Postolache, F. MAOS—Oxygen minimum amount calculation software for thermodynamics processes. Sci. Bull. Naval Acad. 2018, XXI, 430–433. [Google Scholar]
  35. Popa, I.; Sporiș, A.; Mărășescu, D.; Postolache, F.; Volintiru, O.N. Termodinamically process for atmospheric fresh water production. Sci. Bull. Naval Acad. 2022, XXV, 37–44. [Google Scholar]
  36. United States Environmental Protection Agency. Code of Federal Regulations: Priority Pollutants List. 2014. Available online: https://www.gpo.gov/fdsys/pkg/CFR-2014-title40-vol29/xml/CFR-2014-title40-vol29-part423-appA.xml (accessed on 11 November 2023).
  37. Sen, S.; Bizimis, M.; Tripathi, S.N.; Paul, D. Lead isotopic finger-printing of aerosols to characterize the sources of atmospheric lead in an industrial city of India. Atmos. Environ. 2016, 129, 27–33. [Google Scholar] [CrossRef]
  38. Peixoto, M.S.; de Oliveira Galvao, M.F.; Batistuzzo de Medeiros, S.R. Cell death pathways of particulate matter toxicity. Chemosphere 2017, 188, 32–48. [Google Scholar] [CrossRef] [PubMed]
  39. Morakinyo, O.M.; Mukhola, M.S.; Mokgobu, M.I. Health Risk Analysis of Elemental Components of an Industrially Emitted Respirable Particulate Matter in an Urban Area. Int. J. Environ. Res. Public Health 2021, 18, 3653. [Google Scholar] [CrossRef] [PubMed]
  40. Sanborn, M.D.; Abelsohn, A.; Campbell, M.; Weir, E. Identifying and managing adverse environmental health effects: 3. Lead exposure. Can. Med. Assoc. J. 2002, 166, 1287–1292. [Google Scholar]
  41. Faiz, Y.; Tufail, M.; Javed, M.T.; Chaudhry, M.M.; Siddique, N. Road dust pollution of Cd, Cu, Ni, Pb and Zn along Islamabad Expressway, Pakistan. Microchem. J. 2009, 92, 186–192. [Google Scholar] [CrossRef]
  42. Turner, A.; Hefzi, B. Levels and bioaccessibilities of metals in dusts from an arid environment. Water Air Soil Poll. 2010, 210, 483–491. [Google Scholar] [CrossRef]
  43. Bărbulescu, A.; Nazzal, Y.; Howari, F. Statistical analysis and estimation of the regional trend of aerosol size over the Arabian Gulf Region during 2002–2016. Sci. Rep. 2018, 8, 9571. [Google Scholar] [CrossRef]
  44. Nazzal, Y.; Bărbulescu, A.; Howari, F.M.; Yousef, A.; Al-Taani, A.A.; Al Aydaroos, F.; Naseem, M. New insight to dust storm from historical records, UAE. Arab. J. Geosci. 2019, 12, 396. [Google Scholar] [CrossRef]
  45. Bărbulescu, A.; Nazzal, Y. Statistical analysis of the dust storms in the United Arab Emirates. Atmos. Res. 2020, 231, 104669. [Google Scholar] [CrossRef]
  46. Nazzal, Y.H.; Bărbulescu, A.; Howari, F.; Al-Taani, A.A.; Iqbal, J.; Xavier, C.M.; Sharma, M.; Dumitriu, C.S. Assessment of metals concentrations in soils of Abu Dhabi Emirate using pollution indices and multivariate statistics. Toxics 2021, 9, 95. [Google Scholar] [CrossRef]
  47. Nazzal, Y.; Bou Orm, N.; Bărbulescu, A.; Howari, F.; Sharma, M.; Badawi, A.; Al-Taani, A.A.; Iqbal, J.; El Ktaibi, F.; Xavier, C.M.; et al. Study of atmospheric pollution and health risk assessment A case study for the Sharjah and Ajman Emirates (UAE). Atmosphere 2021, 12, 1442. [Google Scholar] [CrossRef]
  48. Yeatts, K.B.; El-Sadig, M.; Leith, D.; Kalsbeek, W.; Al-Maskari, F.; Couper, D.; Funk, W.E.; Zoubeidi, T.; Chan, R.L.; Trent, C.B.; et al. Indoor air pollutants and health in the United Arab Emirates. Environ. Health Perspect. 2012, 120, 687–694. [Google Scholar] [CrossRef] [PubMed]
  49. Jung, C.; Alqassimi, N.; El Samanoudy, G. The comparative analysis of the indoor air pollutants in occupied apartments at residential area and industrial area in Dubai, United Arab Emirates. Front. Built Environ. 2022, 8, 998858. [Google Scholar] [CrossRef]
  50. Mfarrej, B.; Qafisheh, N.A.; Bahloul, M.M. Investigation of Indoor Air Quality inside Houses From UAE. Air Soil Water Resear. 2020, 13, 1–10. [Google Scholar] [CrossRef]
  51. Greywolf Sensing Solutions. Indoor Air Quality (IAQ) Meters, Monitors for Handheld, Semi-Permanent and Long-Term IAQ Measurement. Available online: https://graywolfsensing.com/iaq/?gad_source=1&gclid=CjwKCAiA6byqBhAWEiwAnGCA4GrTejNDxyRzkNIWFkHzN7VQCwwFmry9m5ksqtSG2hxtb--ljiU8txoCU-8QAvD_BwE (accessed on 10 October 2023).
  52. High-Precision Handheld GIS Data Collector-SOUTH S750. Available online: https://pdf.directindustry.com/pdf/south-surveying-mapping-instrument-co-ltd/high-precision-handheld-gis-data-collector-south-s750/160571-732546.html (accessed on 11 October 2023).
  53. Dyson V15 Detect. Available online: https://www.dyson.com/vacuum-cleaners/cordless/v15/detect/yellow-iron (accessed on 11 October 2023).
  54. Method 3050B: Acid Digestion of Sludges, Sediments, and Soils, Revision 2; United States Environmental Protection Agency (USEPA): Washington, DC, USA, 1996.
  55. Code of Federal Regulations (Annual Edition)—Title 40: Protection of Environment, Part 136: Guidelines Establishing Test Procedures for the Analysis of Pollutants. 2022. Available online: https://www.govinfo.gov/app/search/%7B%22query%22%3A%2240%20CFR%20Part%20136%20Appendix%20B%2C%20Revision%202%22%2C%22offset%22%3A0%7D (accessed on 12 November 2023).
  56. Calculating & Using Method Detection Limits. Available online: https://www.wef.org/globalassets/assets-wef/2-resources/online-education/webcasts/presentation-handouts/mdl-webcast-16july20.pdf (accessed on 12 November 2023).
  57. Daburra, I. K-means Clustering: Algorithm, Applications, Evaluation Methods, and Drawbacks. Available online: https://towardsdatascience.com/k-means-clustering-algorithm-applications-evaluation-methods-and-drawbacks-aa03e644b48a (accessed on 18 June 2023).
  58. Hierarchical Clustering in, R. Available online: https://www.datacamp.com/tutorial/hierarchical-clustering-R (accessed on 18 September 2023).
  59. K-Mean: Getting the Optimal Number of Clusters. Available online: https://www.analyticsvidhya.com/blog/2021/05/k-mean-getting-the-optimal-number-of-clusters/ (accessed on 16 June 2023).
  60. Rousseeuw, P. Silhouettes: A Graphical Aid to the Interpretation and Validation of Cluster Analysis. J. Comput. Appl. Math. 1987, 20, 53–65. [Google Scholar] [CrossRef]
  61. Farris, J.S. On the cophenetic correlation coefficient. Syst. Zool. 1969, 18, 279–285. [Google Scholar] [CrossRef]
  62. Murphy, P. Clustering Data in R. Available online: https://rstudio-pubs-static.s3.amazonaws.com/599072_93cf94954aa64fc7a4b99ca524e5371c.html#Visualize (accessed on 14 October 2023).
  63. Jolliffe, I. Principal Component Analysis; Wiley: Hoboken, NJ, USA, 2014. [Google Scholar]
  64. Davis, J.C. Statistics and Data Analysis in Geology, 2nd ed.; John Wiley and Sons, Inc.: New York, NY, USA, 1982. [Google Scholar]
  65. Kolsi, S.H.; Bouri, S.; Hachicha, W.; Dhia, H.B. Implementation and evaluation of multivariate analysis for groundwater hydrochemistry assessment in arid environments: A case study of Hajeb Elyoun–Jelma, Central Tunisia. Environ. Earth Sci. 2013, 70, 2215–2224. [Google Scholar] [CrossRef]
  66. Cattell, R.B. The Scree Test for The Number of Factors. Multivar. Behav. Res. 1966, 1, 245–276. [Google Scholar] [CrossRef] [PubMed]
  67. Kaiser, H.F. The application of electronic computers to factor analysis. Educ. Psychol. Meas. 1960, 20, 141–151. [Google Scholar] [CrossRef]
  68. Kowalska, J.B.; Mazurek, R.; Gąsiorek, M.; Zaleski, T. Pollution indices as useful tools for the comprehensive evaluation of the degree of soil contamination—A review. Environ. Geochem. Health 2018, 40, 2395–2420. [Google Scholar] [CrossRef]
  69. Al-Hejuje, M.M.; Al-Saad, H.T.; Hussain, N.A. Application of geo-accumulation index (I-geo) for assessment the sediments contamination with heavy metals at Shatt Al-Arab River-Iraq. J. Sci. Eng. Res. 2018, 5, 342–351. [Google Scholar]
  70. Sutherland, R.A. Bed sediment-associated trace metals in an urban stream, Oahu, Hawaii. Environ. Geol. 2000, 39, 611–627. [Google Scholar] [CrossRef]
  71. Lindsay, W.L. Chemical Equilibrium in Soils; John Wiley & Sons: New York, NY, USA, 1979. [Google Scholar]
  72. Kabata-Pendias, A. Trace Elements of Soils and Plants, 4th ed.; CRC Press: Boca Raton, FL, USA; Taylor & Francis Group: Abingdon, UK, 2011. [Google Scholar]
  73. Selvam, A.P.; Priya, S.L.; Banerjee, K.; Hariharan, G.; Purvaja, R.; Ramesh, R. Heavy Metal Assessment Using Geochemical and Statistical Tools in the Surface Sediments of Vembanad Lake, Southwest Coast of India. Environ. Monit. Assess. 2012, 184, 5899–5915. [Google Scholar] [CrossRef] [PubMed]
  74. Gong, Q.; Deng, J.; Xiang, Y.; Wang, Q.; Yang, L. Calculating pollution indices by heavy metals in ecological geochemistry assessment and a case study in parks of Beijing. J. China Univ. Geosci. 2008, 19, 230–241. [Google Scholar]
  75. Pramanik, A.K.; Majumdar, D.; Chatterjee, A. Factors affecting lean, wet-season water quality of Tilaiya reservoir in Koderma District, India during 2013–2017. Water Sci. 2020, 34, 85–97. [Google Scholar] [CrossRef]
  76. Cude, C.G. Oregon water quality index: A tool for evaluating water quality management effectiveness. J. Am. Water Resour. Assoc. 2001, 37, 125–137. [Google Scholar] [CrossRef]
  77. Howari, F.M.; Ghrefat, H.; Nazzal, Y.; Galmed, M.A.; Abdelghany, O.; Fowler, A.R.; Sharma, M.; AlAygaroos, F.; Xavier, C.M. Delineation of Copper Mineralization Zones at Wadi Ham, Northern Oman Mountains, United Arab Emirates Using Multispectral Landsat 8 (OLI) Data. Front. Earth Sci. 2020, 8, 578075. [Google Scholar] [CrossRef]
  78. Manganese Ore in United Arab Emirates. Available online: https://oec.world/en/profile/bilateral-product/manganese-ore/reporter/are (accessed on 14 October 2023).
  79. Iron Ore in United Arab Emirates. Available online: https://oec.world/en/profile/bilateral-product/iron-ore/reporter/are (accessed on 14 October 2023).
  80. 5 Largest Aluminum Producing Countries in the World. Available online: https://www.insidermonkey.com/blog/5-largest-aluminum-producing-countries-in-the-world-1159098/ (accessed on 14 October 2023).
  81. Baek, S.O.; Kim, Y.S.; Perry, R. Indoor air quality in homes, offices, and restaurants in Korean urban areas—Indoor/outdoor relationships. Atmos. Environ. 1997, 31, 529–544. [Google Scholar] [CrossRef]
  82. Jones, N.C.; Thornton, C.A.; Mark, D.; Harrison, R.M. Indoor/outdoor relationships of particulate matter in domestic. Atmos. Environ. 2000, 34, 2603–2612. [Google Scholar] [CrossRef]
  83. Kuo, H.W.; Shen, H.Y. Indoor and outdoor PM2.5 and PM10 concentration in the air during a dust storm. Build. Environ. 2010, 45, 610–614. [Google Scholar] [CrossRef]
  84. Meadow, J.F.; Altrichter, A.E.; Kembel, S.W.; Kline, J.; Mhuireach, G.; Moriyama, M.; Northcutt, D.; O’Connor, T.K.; Womack, A.M.; Brown, G.Z.; et al. Indoor airborne bacterial communities are influenced by ventilation, occupancy, and outdoor air source. Indoor Air 2014, 24, 41–48. [Google Scholar] [CrossRef]
  85. Fung, C.C.; Yang, P.; Zhu, Y.F. Infiltration of Diesel Exhaust into a Mechanically Ventilated Building. In Proceedings of the Indoor Air 2014—13th International Conference on Indoor Air Quality and Climate, Hong Kong, 7–12 July 2014. Paper#HP0626. [Google Scholar]
  86. Ai, Z.T.; Mak, C.M. From street canyon microclimate to indoor environmental quality in naturally ventilated urban buildings: Issues and possibilities for improvement. Build. Environ. 2015, 94, 489–503. [Google Scholar] [CrossRef] [PubMed]
  87. Meier, R.; Schindler, C.; Eeftens, M.; Aguilera, I.; Ducret-Stich, R.E.; Ineichen, A.; Davey, M.; Phuleria, H.C.; Probst-Hensch, N.; Tsai, M.Y.; et al. Modeling indoor air pollution of outdoor origin in homes of SAPALDIA subjects in Switzeland. Environ. Int. 2015, 82, 85–91. [Google Scholar] [CrossRef] [PubMed]
  88. Mohammadi, M.; Calautit, J. Quantifying the Transmission of Outdoor Pollutants into the Indoor Environment and Vice Versa—Review of Influencing Factors, Methods, Challenges and Future Direction. Sustainability 2022, 14, 10880. [Google Scholar] [CrossRef]
  89. Härdle, W.; Simar, L. Applied Multivariate Statistical Analysis, 2nd ed.; Springer: Berlin Heidelberg, Germany, 2007. [Google Scholar]
  90. Müller, G. Heavy Metals in the Sediments of the Rhine: Changes since 1971. A look around. Sci. Technol. 1979, 79, 778–783. [Google Scholar]
Figure 1. Study area location and sampling map. The red points and the numbers represent the sampling points and their IDs.
Figure 1. Study area location and sampling map. The red points and the numbers represent the sampling points and their IDs.
Toxics 11 00933 g001
Figure 2. The correlation matrix. The higher the positive correlation, the more intense the nuance of red. The higher the negative correlation, the more intense the nuance of blue is. The nuances of light yellow, light orange, and indigo indicate a low or inexistent correlation.
Figure 2. The correlation matrix. The higher the positive correlation, the more intense the nuance of red. The higher the negative correlation, the more intense the nuance of blue is. The nuances of light yellow, light orange, and indigo indicate a low or inexistent correlation.
Toxics 11 00933 g002
Figure 3. (a) Elbow and (b) silhouette methods for selecting the number of clusters.
Figure 3. (a) Elbow and (b) silhouette methods for selecting the number of clusters.
Toxics 11 00933 g003
Figure 4. (a) The clusters found by k-means with k = 2; (b) Dendrogram in the hierarchical clustering.
Figure 4. (a) The clusters found by k-means with k = 2; (b) Dendrogram in the hierarchical clustering.
Toxics 11 00933 g004
Figure 5. (a) The screen plot and (b) loading table.
Figure 5. (a) The screen plot and (b) loading table.
Toxics 11 00933 g005
Figure 6. (a) Cos2 of variables to Dim 1–2; (b) Cos2 of variables to Dim 2–3; (c) Cos2 of variables to Dim 1–3.
Figure 6. (a) Cos2 of variables to Dim 1–2; (b) Cos2 of variables to Dim 2–3; (c) Cos2 of variables to Dim 1–3.
Toxics 11 00933 g006
Figure 7. Variables—PCA.
Figure 7. Variables—PCA.
Toxics 11 00933 g007
Figure 8. CPI and CPI-Ca.
Figure 8. CPI and CPI-Ca.
Toxics 11 00933 g008
Figure 9. AQI and AQI-Ca.
Figure 9. AQI and AQI-Ca.
Toxics 11 00933 g009
Figure 10. (a). The clusters found by k-means with k = 2; (b) Dendrogram from the hierarchical clustering for Set2.
Figure 10. (a). The clusters found by k-means with k = 2; (b) Dendrogram from the hierarchical clustering for Set2.
Toxics 11 00933 g010
Figure 11. Biplot in PCA for Set2.
Figure 11. Biplot in PCA for Set2.
Toxics 11 00933 g011
Table 1. Basic statistics of the series of elements from the dust samples [mg/kg].
Table 1. Basic statistics of the series of elements from the dust samples [mg/kg].
CuNiPbZnCoCrBaFeMn
min3.0429.850.0525.810.1619.1428.96568.3666.38
mean94.3052.144.62247.081.8556.9685.17997.28126.58
max309.5893.5028.82397.113.62298.47309.941572.14186.24
median53.5447.102.37255.841.9133.2774.36979.05133.08
Std.dev.97.7418.806.7292.520.9563.6055.28263.6743.47
CV1.040.361.460.370.521.120.650.260.34
Skewness coef.1.530.722.86−0.570.043.063.540.40−0.04
Kurtosis0.65−0.578.470.10−0.7610.3114.39−0.03−1.71
MgSrNaAlCaKAsCd
min834.3211.44188.15349.338033.173918.610.646.26
mean1876.2247.50561.391033.7814,170.029159.123.896.73
max4972.55120.351606.821883.3820,421.2917,984.385.617.45
median1843.2744.64493.99965.5414,436.288661.694.266.68
Std.dev.928.0923.21295.98391.793085.022873.001.410.32
CV0.490.490.530.380.220.310.360.05
Skewness coef1.861.432.430.70−0.361.28−0.850.46
Kurtosis5.103.527.290.600.043.52−0.01−0.43
Table 2. p-values related to the correlation coefficients of the elements found in the dust. The shaded cells, containing p-values less than 0.05 (the level of significance), indicate the existence of a significant correlation between the elements from the line and columns that intersect at that cell.
Table 2. p-values related to the correlation coefficients of the elements found in the dust. The shaded cells, containing p-values less than 0.05 (the level of significance), indicate the existence of a significant correlation between the elements from the line and columns that intersect at that cell.
CuNiPbZn CoCr Ba Fe Mn Mg Sr Na Al CaK As
Ni0.465
Pb0.1180.104
Zn0.1050.4840.945
Co0.3860.0000.1530.537
Cr0.2800.5460.1010.9300.825
Ba0.9360.4460.8690.9660.3000.705
Fe0.9610.0000.6050.2670.0000.9550.400
Mn0.8170.0000.2260.0110.0000.8620.8810.000
Mg0.3910.0350.8670.0930.1460.4950.8330.0120.000
Sr0.8820.0070.7630.1060.0090.9240.6370.0270.0110.272
Na0.2850.7340.3140.1090.8220.6760.5900.4330.1640.4690.401
Al0.9370.0010.9490.3020.0020.3510.3870.0000.0010.0110.1680.838
Ca0.9630.1590.5870.0020.2020.8240.7830.0680.0000.0660.0300.0050.100
K0.8800.5960.9240.2570.2760.9230.9570.3960.8470.7170.9780.3360.3720.108
As0.7840.8160.2000.6710.7050.7390.9090.4160.7000.2650.5160.1160.1880.8040.389
Cd0.8160.0000.4610.0760.0020.4930.8900.0000.0000.0160.0030.1250.0010.0040.4930.829
Table 3. PCA.
Table 3. PCA.
PC1PC2PC3PC4PC5
Standard deviation1.3140.5360.4630.2710.249
Proportion of Variance0.69350.11520.08580.02940.0249
Cumulative Proportion 0.69350.80870.89460.92410.9489
Table 4. Igeo values, corresponding contamination levels, and the sites included in each class [90].
Table 4. Igeo values, corresponding contamination levels, and the sites included in each class [90].
Igeo ClassIgeo ValueContamination LevelContamination Level at the Study Sites
0Igeo ≤ 0UncontaminatedCu, Ni, Pb, Co, Cr, Ba, Sr, Mn, Sa Cd—all sitesZn: 1–6, 12–14, 16–19; Na: 1–6, 8–19; Al: 9–19, As, Cd
10 < Igeo < 1Uncontaminated/Moderately contaminatedZn: 7–11, 15, 20; Na: 7, 20; Fe: 7, 9, 17; Mg: 17; Al: 1, 3, 7, 8, 10–18, 20
21 ≤ Igeo < 2Moderately contaminatedFe: 1, 3–5, 8, 10–16, 18–20; Mg: 1, 7–9, 11, 18–20; Al: 2, 4–6; K: 17
32 ≤ Igeo < 3Moderately/Strongly contaminatedFe: 2, 6; Mg: 2, 4–6, 10, 12–16; K: 1, 3, 4, 8, 9, 11–13, 15, 20
43 ≤ Igeo < 4Strongly contaminatedMg: 3; K: 2, 5, 7, 9, 15, 18, 19;
54 ≤ Igeo < 5Strongly/Extremely contaminatedCa: 1, 6–11, 14, 15, 17–20
6Igeo 5Extremely contaminatedCa: 2–5, 12, 13, 16
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Nazzal, Y.; Bărbulescu, A.; Sharma, M.; Howari, F.; Naseem, M. Evaluating the Contamination by Indoor Dust in Dubai. Toxics 2023, 11, 933. https://doi.org/10.3390/toxics11110933

AMA Style

Nazzal Y, Bărbulescu A, Sharma M, Howari F, Naseem M. Evaluating the Contamination by Indoor Dust in Dubai. Toxics. 2023; 11(11):933. https://doi.org/10.3390/toxics11110933

Chicago/Turabian Style

Nazzal, Yousef, Alina Bărbulescu, Manish Sharma, Fares Howari, and Muhammad Naseem. 2023. "Evaluating the Contamination by Indoor Dust in Dubai" Toxics 11, no. 11: 933. https://doi.org/10.3390/toxics11110933

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop