Article

Comparative Study of Entropy Sensitivity to Missing Biosignal Data

1
Technological Institute of Informatics, Polytechnic University of Valencia, Alcoi Campus, Plaza Ferrandiz y Carbonell, 2, Alcoi 03801, Spain
2
Department of Statistics, Polytechnic University of Valencia, Alcoi Campus, Plaza Ferrandiz y Carbonell, 2, Alcoi 03801, Spain
*
Author to whom correspondence should be addressed.
Entropy 2014, 16(11), 5901-5918; https://doi.org/10.3390/e16115901
Submission received: 3 July 2014 / Revised: 5 August 2014 / Accepted: 3 November 2014 / Published: 10 November 2014
(This article belongs to the Special Issue Entropy and Electroencephalography)

Abstract

:
Entropy estimation metrics have become a widely used method to identify subtle changes or hidden features in biomedical records. These methods have been more effective than conventional linear techniques in a number of signal classification applications, specially the healthy–pathological segmentation dichotomy. Nevertheless, a thorough characterization of these measures, namely, how to match metric and signal features, is still lacking. This paper studies a specific characterization problem: the influence of missing samples in biomedical records. The assessment is conducted using four of the most popular entropy metrics: Approximate Entropy, Sample Entropy, Fuzzy Entropy, and Detrended Fluctuation Analysis. The rationale of this study is that missing samples are a signal disturbance that can arise in many cases: signal compression, non-uniform sampling, or data transmission stages. It is of great interest to determine if these real situations can impair the capability of segmenting signal classes using such metrics. The experiments employed several biosignals: electroencephalograms, gait records, and RR time series. Samples of these signals were systematically removed, and the entropy computed for each case. The results showed that these metrics are robust against missing samples: With a data loss percentage of 50% or even higher, the methods were still able to distinguish among signal classes.

Graphical Abstract

1. Introduction

A number of types of entropy estimation measures and their possible applications have been reported in the scientific literature in recent years. These nonlinear metrics have been employed in multiple scientific fields for the analysis of time series, yielding better results than other conventional methods [13].
There is a myriad of such applications in the specific biomedical signal framework because biological systems are great entropy generators [4]. In this context, entropy estimates have been successfully used in cardiology [59], neurology [1015], neonatology [1620], and pneumology [21,22], among others.
An ongoing characterization effort has been lately undertaken to gain a better understanding of signal entropy measures and their properties [4]. Works such as [23,24] have studied the influence of parameters like signal length or thresholds. The studies reported in [2527] analyzed their essential features in terms of bandwidth and signal complexity. Garcia-Gonzalez [28] and Molina-Pico [29], assessed robustness against signal outliers.
Nevertheless, some issues related to entropy measures characterization have not been addressed yet. We describe in this paper a characterization scheme aimed at assessing the influence of missing data on entropy estimates. Missing data are not unusual in biomedical signals. Time series are vulnerable to uncontrolled factors such as noise [30] or outliers, but other technical processes may cause missing points such as wireless or network data transmission [31,32], signal compression [33,34], non-uniform sampling, trace segmentation [35], or resampling.
This study is focused on four of the most used regularity metrics in the context of biomedical signal processing: Approximate Entropy (ApEn), Sample Entropy (SampEn), Fuzzy Entropy (FuzzyEn), and Detrended Fluctuation Analysis (DFA). Other metrics have been evaluated in previous studies [36]. Our work assesses the robustness of the entropy measures enumerated above against missing data in terms of signal discrimination potential. In particular, we aimed to assess the possible deterioration of the pathology detection capability of these measures. This characterization study is illustrated by considering detection of signal classes from a diverse biosignal population: electroencephalogram signals (EEG), gait dynamics records, and RR interval time series.
The remainder of this article is structured as follows. In Section 2, we introduce the four entropy metrics to be characterized in terms of robustness against data loss. We describe in Section 3 the experiments and the dataset employed. In Section 4, the statistical results are presented, as a function of the data loss ratio. In Section 5, we interpret our findings. Finally, the conclusion section summarizes the main results of the study.

2. Method

The experimental dataset was processed using ApEn, SampEn, FuzzyEn and DFA. Each metric was computed for each record, and for different data loss levels, within a signal classification scheme. The signal segmentation probability was computed. The objective of the method was to assess whether these measures were stable as a function of the data loss ratio.
Specifically, the measures of ApEn, SampEn, FuzzyEn and DFA were computed for every record in the experimental set for data loss percentages of 0% (baseline), 10%, 30%, 50%, 70%, and 90%. There were 100 realizations for each signal. Each sample could only be deleted once. The spare samples were removed using two approaches:
  • Uniform sample removal. This scheme accounts for data loss that might occur during wireless or network data transmission, or acquisition saturation. The number of samples to remove (X) was set as a function of a percentage proportional to the total data series length. The removal started at a sample chosen randomly. Therefore, an epoch of X consecutive samples commencing at a random time was removed in this case. The step X was defined in accordance with the specified sample loss percentage.
  • Random sample removal. This scheme accounts for data loss that might occur during non-uniform sampling, trace segmentation, or lossy compression. The X samples to be removed were selected according to a random distribution.
The resulting entropy values were used in a statistical comparative analysis to find out if the downsampled signals could still be segmented as they were for the baseline case. Data Gaussianity was tested before applying the parametric t-test. The p-value threshold was set to 0.05.
Two populations were compared with this test, corresponding to the control and the epileptic classes in EEG signals, the Pre-Treatment (PT) and the On-Treatment (OT) records in RR series, and the pathologic versus the control groups in gait signals. A hypothesis testing with this p-value indicates that the two classes are found different by the entropy metrics.
Given an input time series u(n) of length N, with n = 0, 1, … , N − 1, the algorithms to calculate ApEn, SampEn, FuzzyEn, and DFA metrics can be described as follows.

2.1. ApEn

ApEn is a family of statistics first proposed in [9]. Despite its well-known weaknesses, such as counting self-matches and being very dependent on signal length [8,37,38], ApEn is still able to unveil significant clinical information from biomedical records [25,39]. It is probably the entropy estimator most used in the context of biosignal classification.
The mathematical definition of ApEn is as follows: Let x(i) be an epoch of m consecutive values of u(n) taken at the ith point [9], subject to N ≥ 10m: x(i) = [u(i), u(i + 1), …, u(i + m − 1)]. The input parameter m is usually recommended to be 2 or 3 in order to obtain a good statistical validity [9,38]. We used m = 2. Let d(i, j) be a dissimilarity measure between two runs, namely:
d ( i , j ) = d ( x ( i ) , x ( j ) ) = max k { | x ( i + k 1 ) x ( j + k 1 ) | } k = 1 , , m
The input parameter r represents a filter threshold in terms of signal variance σu. In practice, r is chosen to be between 0.1σu and 0.25σu. Smaller values would yield numerically unstable conditional probabilities and larger values could result in too much detail information lost due to filter coarseness [9]. We used r = 0.15σu.
Defining a dissimilarity thresholding function y(i) as:
y ( j ) = { 1 d ( i , j ) r 0 d ( i , j ) > r
and a counting function C i m ( r ) as:
C i m ( r ) = 1 N m + 1 j = 1 N m + 1 y ( j )
ApEn(m, r, N) can then be estimated as the likelihood ratio:
ApEn ( m , r , N ) = Φ m ( r ) Φ m + 1 ( r )
where Φm(r) is computed as follows:
Φ m ( r ) = 1 N m + 1 i = 1 N m + 1 ln { C i m ( r ) }

2.2. SampEn

SampEn was first proposed by Richman and Moorman in 2002 [8]. It was devised as a solution to reduce the ApEn bias due to counting self-matches and therefore it is supposed to yield a more robust statistic. SampEn is a measure that estimates the regularity of a time series by computing the negative logarithm of the conditional probability that two sequences, which are similar for m points, remain similar for m + 1 points [8,40].
SampEn is largely independent of the record length and exhibits relative consistency under circumstances where ApEn does not. SampEn agrees much better than ApEn statistics with theory for random numbers over a broad range of operating conditions [68].
The algorithm to compute SampEn is simpler than that of ApEn. The first steps are the same, but Equation (2) becomes:
C i m ( r ) = 1 N m 1 j i j = 1 N m y ( j )
being m and r the same parameters introduced for ApEn. The value for y(j) is computed as defined in Equation (1), and Equation (4) turns into:
Φ m ( r ) = 1 N m i = 1 N m C i m ( r )
Finally, SampEn(m, r, N) is obtained as:
SampEn ( m , r , N ) = ln ( Φ m ( r ) ) ln ( Φ m + 1 ( r ) )

2.3. FuzzyEn

FuzzyEn was first proposed in [41] in order to characterize surface electromyograms time series regularity and overcome the poor statistical stability in ApEn and SampEn [41,42]. FuzzyEn imported the idea of “fuzzy sets” proposed by Zadeh [43]. FuzzyEn introduces a membership function, μZ(x) that evaluates the degree in which a pattern belongs to a class Z. The closer the value to 1, the higher the membership grade of pattern x belonging to that class.
The membership function proposed by Chen [41] is an exponential function. Any such function must be continuous and convex, so that the similarity does not change abruptly [41,42].
The FuzzyEn algorithm is similar to that of SampEn [8]. The main differences include the membership function used to compute the matches to be found and the way the runs are defined. For the input sequence u(n) introduced in Section 2.1, the runs of m points now become:
x ( i ) = [ u ( i ) u ( i + 1 ) u ( i + m 1 ) ] u 0 ( i )
where u0(i) represents the baseline of x(i) and is estimated as follows:
u 0 ( i ) = 1 m j = 0 m 1 u ( i + j )
The distance between two runs d(i, j) is computed as described for ApEn and SampEn. Next, given q and r, the similarity D i j m between x(i) and x(j) is calculated according to:
D i j m ( q , r ) = μ ( d i j m , q , r )
where μ ( d i j m , q , r ) is the membership function given by:
μ ( d i j m , p , r ) = exp ( ( d i j m ) n / r )
The similarity degree D i j m computed for FuzzyEn is like the value y(n) computed for ApEn and SampEn. The following step is to obtain C i m ( r ) as defined for SampEn where y(n) is replaced by D i j m, and calculate the conditional probabilities in the same way as for SampEn according to Equation (5).
ϕ m ( q , r ) = 1 N m i = 1 N m C i m ( r , n )
C i m ( q , r ) = 1 N m 1 j = 1 , j i N m D i j m
Finally, FuzzyEn is computed as defined in Equation (6) from the previous values obtained. The parameters m and r are defined as in ApEn or SampEn [41], but q has to be defined. The parameter q accounts for the width of the exponential function and it is usually set to a small integer value greater than 1 in order to avoid the information loss due to wider exponential functions. Typically q = 2 [41,42,44].

2.4. Detrended Fluctuation Analysis (DFA)

DFA quantifies the regularity of a time series by detecting long range correlations embedded in a nonstationary time series [5]. As it only considers the fluctuations from local trends, DFA is capable of avoiding the spurious detection of apparent long range correlations that are nonstationary artifacts. However, it is also sensitive to series length N. When time series are short, DFA can exhibit a fluctuating behavior [5,13,45].
DFA is computed as a modified root mean square of a random walk. The first step of the algorithm is to generate the random walk [13] by integrating the input sequence:
U ( k ) = i = 0 k u ( i ) u ¯ , with k = 0 , 1 , , N 1
where u ¯ = 1 N j = 0 N 1 u ( j ) .
The input sequence u(n) is divided into non-overlapping runs of length L. A linear fit is used to approximate this sequence in each window Wj, j = 1, …, M. The local trend at window Wj is denoted U W j ( k ). This local trend is subtracted from the integrated series U ( k ) U W j ( k ). A mean square fluctuation of the integrated and detrended time series can then be computed as described in [5]:
F ( L ) = 1 N k = 0 N 1 ( U ( k ) U W i ( k ) ) 2
These calculations are repeated for a set of window lengths. Let L = {L1, L2LiLn} be a windowing length sequence. The minimum Li value corresponds to the order of the DFA plus two samples. The maximum value depends on the approach used. In [5], the maximum value is the length of the signal (N). Others such as [45] take it as N/4 and [10] uses the value of N/10. Typically, FL increases with the window length.
If a time series is self-similar, a relationship indicates the presence of a power law scaling FLLα. The value of α accounts for the correlation properties of the data. The DFA coefficient α can be obtained as the slope of the line fit on the log–log plot of FL as a function of L [5]. Large values of α denote smooth time series. An example is depicted in Figure 1.
The coefficient α usually ranges from 0 to 2 [10]. Three major intervals may be defined:
  • For 0 ≤ α ≤ 0.5: The time series contains power law correlations but of different type.
  • For 0.5 < α ≤ 1.0: The time series contains persistent long range power law correlations.
  • For α > 1.0: There are correlations in the time series but nothing is known about their nature.
The windowing sequence L in this work has been chosen to include 50 equispaced values in the logarithmic scale between Li minimum and N/4. Those logarithmic lengths that yield the same integer values have been removed.

3. Experimental Dataset

3.1. EEG Dataset

The EEG records were drawn from the public database of the Clinic of Epileptology, Bonn University, Department of Neurophysics [14]. The records of this database were obtained from continuous multichannel EEGs, cut out to remove artifacts. Five EEG classes, denoted from A to E, were available. Class A corresponds to surface EEG recordings acquired on five healthy volunteers relaxed in an awake state with eyes open. The electrodes were placed using standard locations. In class B, the same conditions apply except that in this case eyes were closed. Sets C, D and E correspond to EEGs of presurgical diagnosis of five epileptic patients after resection of one of the hippocampal formations. Records in D were drawn from the epileptogenic zone, while those in set C were recorded from the hippocampal formation. Both classes D and C contain only activity during seizure free intervals, whereas records in set E contain only seizure activity.
The signal sampling rate was 173.61 Hz, using a 12 bit analog-to-digital converter. The duration of each record was 23.6 s (4096 samples). Each class contains in total 100 single channel EEG segments. Figure 2 shows the EEG and the power spectral density (PSD) for one representative signal for each data group of the database.
Two new signal groups were considered for the experiments: control (original types A and B), and pathologic (original types C, D, and E). The objective was to assess the capability of these measures to segment between signals that conceptually correspond to healthy and pathologic subjects, as would be the case in a clinical analysis.

3.2. RR Interval Time Series Dataset

The RR records were drawn from the public Cardiac Arrhythmia Suppression Trial (CAST) database [46]. This database consists of 1725 post-acute myocardial infarction patients that were randomized to have three times daily either a placebo, encainide, flecainide, or moricizine [4749]. Only encainide signals were used in this work.
For completeness, only 734 recordings of length 1000 samples constitute the experimental RR record database [50]. There are three groups of records in this set for the three medications given to the subjects. The name of each record includes a prefix to account for the type of medication: e, f, and m, respectively, and a suffix to indicate if medication was given, b (on-therapy OT records), or not, a (pre-therapy PT records). The groups to be segmented in the experiments were precisely the PT and the OT records within signal types e, f, and m.

3.3. Gait Dynamics Records Dataset

The gait dynamics records were drawn from the neuro-degenerative disease database [46]. It consists of 64 signals from which 16 are healthy control subjects, 15 suffer from Parkinson’s Disease (PD), 20 from Huntington’s Disease (HD), and 13 from Amyotrophic Lateral Sclerosis (ALS).
Initially, data were obtained using force transducers, where the values were proportional to the pressure under the foot. From these series, footfall times could be estimated [51,52].
Each record is named after the subject class (hunt, park, als, or control), followed by a number. Each record has four associated files: header, left foot signal, right foot signal, and derived time series. This last time series includes a number of subrecords, but for simplicity in this work we only analyzed right stance intervals measured as a stride percentage. The objective of the segmentation was to assess if the entropy metrics were able to distinguish pathologic signals hunt, park and als, from control.

4. Results

All the experimental records in the dataset underwent different ratios and types of sample loss as described in Section 2, and their entropy metrics were computed in each case. These metrics were then used in a statistical test to assess the differences among groups. In case of significance, the metric was considered able to segment signals even on undersampled data. Otherwise, the metric was considered not robust enough for the application. The specific quantitative results are described next for each experiment.

4.1. Random Sample Removal Results

The results obtained for random sample removal using EEG, RR interval time series, and gait dynamics (percentage of Right Stance Interval in Double Support Interval for ALS, PD, HD) records, are shown in Tables 15 respectively.

4.2. Uniform Sample Removal Results

The results obtained for uniform sample removal using EEG, RR interval time series, and gait dynamics records (ALS, PD, HD), are shown in Tables 610 respectively.

5. Discussion

When samples are removed from biomedical records, the entropy metrics results change, as could be expected since the input data are modified. Nevertheless, the absolute value of these measures is not usually the goal of the calculations, but their relative value in comparison among classes.
In this regard, our study was devised to find out if the relative differences among such classes were kept even with some degree of data loss. This would enable the utilization of entropy estimators even under harsh conditions in normal procedures such as record compression, signal resampling, or data transmission applications.
From the results, in most cases, the measures were still able to distinguish between the two groups under test, since the test probability was p < 0.05. However, there are a few cases where the segmentation power was lost that have to be taken into account.
The negative cases are mainly in the experiments using SampEn and RR time series records, and FuzzyEn and gait records, whereas for the rest of the experiments, with some exceptions, the results were positive. This is due to, on one hand, the nature of the input series, and, on the other hand, the properties of the metric employed.
For narrowband signals, such as the RR records, removing samples could imply removing a fairly high amount of signal information. On the contrary, broadband signals such as EEGs can keep most of the information even with the removal of some samples (Gaussian noise-like). In addition, some records include spikes very different to the underlying data (RR series, gait records). These spikes, as studied in [29], also may have a great influence on the entropy metrics.
Regarding the performance of SampEn, it is very sensitive to the number of matches. Thus, its strength of omitting self-matches may turn into a weakness when only a limited number of matches are found, as happens in RR records. This is why SampEn does not find differences for RR records even in the baseline case. The use of random or uniform removal adds minor differences in terms of worse performance for random removal, as could be expected since the uniform approach is more regular.
FuzzyEn is another recent entropy estimator whose performance is expected to be superior to that of ApEn and SampEn. Nevertheless, it requires a third parameter q, the width of the exponential function, and therefore it is more difficult to customize for a specific purpose or signal. We had a similar experience with the improved versions of the same metrics, fApEn and qSampEn [53]. Such metrics perform very well, but in some cases they fail because the optimal parameter configuration is very difficult to find. That is what seems to happen with some gait records and FuzzyEn.

6. Conclusions

This work described a comparative study of the influence of signal sample loss in the segmentation capability of four of the most used entropy metrics in the biomedical framework: ApEn, SampEn, FuzzyEn and DFA. The performance of such metrics was illustrated using various records, including EEGs, RR interval time series, and gait dynamics records.
The performance of the methods suffices to be applied under conditions of significant data loss, if the objective is to segment among signal types. The relative differences are kept although the absolute entropy values change. This holds particularly true for broadband signals, such as the EEG. This conclusion enables the use of lossy data compression techniques or resampling methods for records that will later be processed using entropy estimators.
Of the four entropy measures studied, ApEn seems to be the most robust one, using a standard parameter configuration. Although SampEn is derived from the improvement of ApEn, there are a few cases where ApEn still outperforms SampEn, like the case introduced herein. If no differences are found in the baseline case, it is highly unlikely differences are found for higher ratios, although the relationship is not completely linear. DFA needs longer records and therefore it is not suitable for the epochs employed in this study. It also appears more sensitive to data loss than ApEn and SampEn.
In practical terms, with relatively low data loss ratios, it can be reasonably safe to employ ApEn, SampEn, or FuzzyEn, for classification tasks using biomedical records such as the ones tested, or with similar features. However, generalization is not possible because each metric and each biosignal may exhibit different behavior. Researchers should be advised to perform similar tests as the ones described in the present study if they suspect missing data is damaging their results, and choose entropy metrics and parameters carefully. With a proper configuration, it is very likely that most of the entropy estimators perform well even with severe data loss ratios.

Acknowledgments

This work has been supported by the Spanish Ministry of Science and Innovation, research project TEC2009-14222.

Author Contributions

Eva Cirugeda-Roldan studied and selected several entropy metrics, prepared the experiments, developing the necessary software tools, and obtained the results. She wrote the initial version of the paper. David Cuesta-Frau led the research activities linked to this paper, and the project devoted to characterize entropy measures; introduced the topic of missing data influence on entropy metrics, and some of the experimental records used. He wrote the final version of the paper, the revision, and the response to reviewers. Pau Miro-Martinez and Sandra Oltra-Crespo conducted the statistical analysis and its interpretation.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Garret, D.; Peterson, D.A.; Anderson, C.W.; Thaut, M.H. Comparison of linear, nonlinear, and feature selection methods for EEG signal classification. IEEE Trans. Neural Syst. Rehabil. Eng. 2003, 11, 141–144. [Google Scholar]
  2. Alcaraz, R.; Rieta, J.J. Review: Application of non-linear methods in the study of atrial fibrillation organization. J. Med. Biol. Eng. 2013, 33, 239–252. [Google Scholar]
  3. Muller, R.M.; Anderson, C.W.; Birch, G.E. Linear and nonlinear methods for brain-computer interfaces. IEEE Trans. Neural Syst. Rehabil. Eng. 2003, 11, 165–169. [Google Scholar]
  4. Gao, J.; Hu, J.; Tung, W. Entropy measures for biological signal analyses. Nonlinear Dyn 2012, 68, 431–444. [Google Scholar]
  5. Peng, D.; Havlin, S.; Stanley, H.; Goldberger, A.L. Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series. Chaos 1995, 5, 82–87. [Google Scholar]
  6. Alcaraz, R.; Rieta, J.J. A novel application of Sample Entropy to the electrocardiogram of atrial fibrillation. Nonlinear Anal. Real World Appl 2010, 11, 1026–1035. [Google Scholar]
  7. Lake, D.; Richman, J.; Griffin, M.; Moorman, J. Sample Entropy analysis of neonatal heart rate variability. Am. J. Physiol. Regul. Integr. Comp. Physiol. 2002, 283, R789–R797. [Google Scholar]
  8. Richman, J.; Moorman, J.R. Physiological time-series analysis using Approximate Entropy and Sample Entropy. Am. J. Physiol. Heart Circ. Physiol. 2000, 278, H2039–H2049. [Google Scholar]
  9. Pincus, S.; Gladstone, I.; Ehrenkranz, R. A regularity statistic for medical data analysis. J. Clin. Monit. Comput. 1991, 7, 335–345. [Google Scholar]
  10. Abasolo, D.; Hornero, R.; Escudero, J.; Espino, P. A study on the possible usefulness of Detrended Fluctuation Analysis of the Electroencephalogram background activity in Alzheimer’s disease. IEEE Trans. Biomed. Eng. 2008, 55, 2171–2179. [Google Scholar]
  11. Hwa, R.; Ferree, T. Scaling properties of fluctuations in the human Electroencephalogram. Phys. Rev. E. 2002, 66, 021901. [Google Scholar]
  12. Lee, J.M.; Kim, D.J.; Kim, I.Y.; Park, K.S.; Kim, S.I. Detrended fluctuation analysis of EEG in sleep apnea using MIT/BIH polysomnography data. Comput. Biol. Med. 2002, 32, 37–47. [Google Scholar]
  13. Jospin, M.; Caminal, P.; Jensen, E.; Litvan, H.; Vallverdu, M.; Struys, M.; Vereecke, H.; Kaplan, D. Detrended Fluctuation Analysis of EEG as a measure of depth of anesthesia. IEEE Trans. Biomed. Eng. 2007, 54, 840–846. [Google Scholar]
  14. Andrzejak, R.; Lehnertz, K.; Rieke, C.; Mormann, F.; David, P.; Elger, C. Indications of nonlinear deterministic and finite dimensional structures in time series of brain electrical activity: Dependence on recording region and brain state. Phys. Rev. E. 2001, 64, 061907. [Google Scholar]
  15. Radhakrishnan, N.; Gangadhar, B. Estimating regularity in epileptic seizure time-series data. IEEE Eng. Med. Biol. Mag. 1998, 17, 89–94. [Google Scholar]
  16. Burnsed, J.; Quigg, M.; Zanelli, S.; Goodkin, H.P. Clinical severity, rather than body temperature, during the rewarming phase of therapeutic hypothermia affect quantitative EEG in neonates with hypoxic ischemic encephalopathy. J. Clin. Neurophysiol. 2011, 28, 10–14. [Google Scholar]
  17. Deffeyes, J. E.; Harbourne, R.T.; Dejong, S.L.; Kyvelidou, A.; Stuberg, W.A.; Stergiou, N. Use of information entropy measures of sitting postural sway to quantify developmental delay in infants. J. NeuroEng. Rehabil. 2009, 6. [Google Scholar] [CrossRef]
  18. Moorman, J.R.; Delos, J.B.; Flower, A.A.; Cao, H.; Kovatchev, B.P.; Richman, J.S.; Lake, D.E. Cardiovascular oscillations at the bedside: Early diagnosis of neonatal sepsis using heart rate characteristics monitoring. Physiol. Meas. 2011, 32, 1821–1832. [Google Scholar]
  19. Zhang, D.; Ding, H.; Liu, Y.; Zhou, C.; Ding, H.; Ye, D. Neurodevelopment in newborns: A Sample Entropy analysis of Electroencephalogram. Physiol. Meas. 2009, 30, 491–504. [Google Scholar]
  20. Deffeyes, J.E.; Kochi, N.; Harbourne, R.T.; Kyvelidou, A.; Stuberg, W.A.; Stergiou, N. Nonlinear Detrended Fluctuation Analysis of sitting Center-of-Pressure data as an early measure of motor development pathology in infants. Nonlinear Dyn. Psychol. Life Sci 2009, 13, 351–368. [Google Scholar]
  21. Veiga, J.; Lopes, A.; Jansen, J.; Melo, P. Airflow pattern complexity and airway obstruction in asthma. J. Appl. Physiol. 2011, 111, 412–419. [Google Scholar]
  22. Charleston-Villalobos, S.; Albuerne-Sanchez, L.; Gonzalez-Camarena, R.; Mejia-Avila, M.; Carrillo-Rodriguez, G.; Aljama-Corrales, T. Linear and nonlinear analysis of base lung sound in extrinsic allergic alveolitis patients in comparison to healthy subjects. Methods Inf. Med. 2013, 52, 266–276. [Google Scholar]
  23. Hu, J.; Gao, J.; Principe, J.C. Analysis of biomedical signals by the Lempel–Ziv complexity: The effect of finite data size. IEEE Trans. Biomed. Eng. 2006, 53, 2606–2609. [Google Scholar]
  24. Maestri, R.; Pinna, G.D.; Porta, A.; Balocchi, R.; Sassi, R.; Signorini, M.G.; Dudziak, M.; Raczak, G. Assessing nonlinear properties of heart rate variability from short-term recordings: Are these measurements reliable? Physiol. Meas. 2007, 28, 1067–1077. [Google Scholar]
  25. Hornero, R.; Aboy, M.; Abasolo, D.; McNames, J.; Goldstein, B. Interpretation of Approximate Entropy: Analysis of intracranial pressure Approximate Entropy during acute intracranial hypertension. IEEE Trans. Biomed. Eng. 2005, 52, 1671–1680. [Google Scholar]
  26. Escudero, J.; Hornero, R.; Abasolo, D. Interpretation of the auto-mutual information rate of decrease in the context of biomedical signal analysis. Application to electroencephalogram recordings. Physiol. Meas. 2009, 30, 187–199. [Google Scholar]
  27. Aboy, M.; Hornero, R.; Abasolo, D.; Alvarez, D. Interpretation of the Lempel–Ziv complexity measure in the context of biomedical signal analysis. IEEE Trans. Biomed. Eng. 2006, 53, 2282–2288. [Google Scholar]
  28. Garcia-Gonzalez, M.; Fernandez-Chimeno, M.; Ramos-Castro, J. Errors in the estimation of Approximate Entropy and other recurrence-plot-derived indices due to the finite resolution of RR time series. IEEE Trans. Biomed. Eng. 2009, 56, 345–351. [Google Scholar]
  29. Molina-Pico, A.; Cuesta-Frau, D.; Aboy, M.; Crespo, C.; Miro-Martinez, P.; Oltra-Crespo, S. Comparative study of Approximate Entropy and Sample Entropy robustness to spikes. Artif. Intell. Med. 2011, 53, 97–106. [Google Scholar]
  30. Lake, D.E.; Richman, J.S.; Griffin, M.P.; Moorman, J.R. Sample Entropy analysis of neonatal heart rate variability. Am. J. Physiol. Regul. Integr. Comp. Physiol. 2002, 283, 789–797. [Google Scholar]
  31. Xu, Y.; Lee, W.C.; Xu, J. Analysis of a loss-resilient proactive data transmission protocol in wireless sensor networks, In Proceedings of the IEEE 26th IEEE International Conference on Computer Communications (INFOCOM 2007), Anchorage, AK, USA, 6–12, May 2007; pp. 1712–1720.
  32. Bao, Y.; Li, H.; Sun, X.; Yu, Y.; Ou, J. Compressive sampling–based data loss recovery for wireless sensor networks used in civil structural health monitoring. Struct. Health Monit 2013, 12, 78–95. [Google Scholar]
  33. Ciocoiu, I.B. ECG. signal compression using 2D Wavelet foveation, In Proceedings of the 2009 International Conference on Hybrid Information Technology (ICHIT 2009), Seoul, Korea, 24–26, November 2009; ACM: New York, NY, USA, 2009; pp. 576–580.
  34. Higgins, G.; Faul, S.; McEvoy, R.P.; McGinley, B.; Glavin, M.; Marnane, W.P.; Jones, E. EEG compression using jpeg2000: How much loss is too much? In Proceedings of the 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2010), Buenos Aires, Argentina, 31 August–4 September 2010; pp. 614–617.
  35. Cuesta-Frau, D.; Perez-Cortes, J.C.; Andreu-Garcia, G. Clustering of electrocardiograph signals in computer-aided holter analysis. Comput. Methods Prog. Biomed. 2003, 72, 179–196. [Google Scholar]
  36. Cirugeda-Roldan, E.; Molina-Pico, A.; Cuesta-Frau, D.; Miro-Martinez, P.; Oltra-Crespo, S. Characterization of entropy measures against data loss: Application to EEG records, In Proceedings of the IEEE Engineering in Medicine and Biology Society Conference (EMBS 2011), Boston, MA, USA, 30 August–3 September 2011; pp. 6110–6113.
  37. Chon, K.; Scully, C.; Lu, S. Approximate Entropy for all signals. Eng. Med. Biol. Mag. 2009, 28, 18–23. [Google Scholar]
  38. Pincus, S.; Goldberger, A.L. Physiological time-series analysis: What does regularity quantify? Am. J. Physiol. 1994, 266, H1643–H1656. [Google Scholar]
  39. Hu, X.; Miller, C.; Vespa, P.; Bergsneider, M. Adaptive computation of Approximate Entropy and its application in integrative analysis of irregularity of heart rate variability and intracranial pressure signals. Med. Eng. Phys. 2008, 30, 631–639. [Google Scholar]
  40. Richman, J. Sample Entropy statistics and testing for order in complex physiological signals. Commun. Stat. Theory Methods 2007, 36, 1005–1019. [Google Scholar]
  41. Chen, W.; Wang, Z.; Xie, H.; Yu, H. Characterization of surface EMG signal based on Fuzzy Entropy. IEEE Trans. Neural Syst. Rehabil. Eng. 2007, 15, 266–272. [Google Scholar]
  42. Chen, W.; Zhuang, J.; Yu, W.; Wang, Z. Measuring complexity using FuzzyEn, ApEn, and SampEn. Med. Eng. Phys. 2009, 31, 61–68. [Google Scholar]
  43. Zadeh, L.A. Fuzzy Sets. Inf. Control. 1965, 8, 338–353. [Google Scholar]
  44. Xie, H.B.; Chen, W.T.; He, W.X.; Liu, H. Complexity analysis of the biomedical signal using fuzzy entropy measurement. Appl. Soft Comput 2011, 11, 2871–2879. [Google Scholar]
  45. Govindan, R.; Wilson, J.; Preissl, H.; Eswaran, H.; Campbell, J.; Lowery, C. Detrended Fluctuation Analysis of short datasets: An application to fetal cardiac data. Physica D 2007, 226, 23–31. [Google Scholar]
  46. Goldberger, A.L.; Amaral, L.A.N.; Glass, L.; Hausdorff, J.M.; Ivanov, P.C.; Mark, R.G.; Mietus, J.E.; Moody, G.B.; Peng, C.K.; Stanley, H.E. PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation 2000, 101, 215–220. [Google Scholar]
  47. Cardiac Arrhythmia Suppression Trial (CAST) Investigators. Effect of antiarrhythmic agent moricizine on survival after myocardial infarction: The cardiac arrhythmia suppression trial-II. N. Engl. J. Med. 1992, 327, 227–233.
  48. Cardiac Arrhythmia Suppression Trial (CAST) Investigators. Preliminary report: Effect of encainide and flecainide on mortality in a randomized trial of arrhythmia suppression after myocardial infarction. N. Engl. J. Med. 1989, 321, 406–412.
  49. Cardiac Arrhythmia Suppression Trial (CAST) Investigators. The cardiac arrhythmia pilot study. Am. J. Cardiol. 1986, 57, 91–95.
  50. Molina-Picó, A.; Cuesta-Frau, D.; Miró-Martínez, P.; Oltra-Crespo, S.; Aboy, M. Influence of QRS complex detection errors on entropy algorithms. Application to heart rate variability discrimination. Comput. Methods Prog. Biomed. 2013, 110, 2–11. [Google Scholar]
  51. Hausdorff, J.M.; Mitchell, S.L.; Firtion, R.; Peng, C.K.; Cudkowicz, M.E.; Wei, J.Y.; Goldberger, A.L. Altered fractal dynamics of gait: Reduced stride-interval correlations with aging and Huntington disease. J. Appl. Physiol. 1997, 82, 262–269. [Google Scholar]
  52. Hausdorff, J.; Lertratanakul, A.; Cudkowicz, M.; Peterson, A.; Kaliton, D.; Goldberger, A. Dynamic markers of altered gait rhythm in Amyotrophic Lateral Sclerosis. J. Appl. Physiol. 2000, 88, 2045–2053. [Google Scholar]
  53. Cirugeda-Roldan, E.M.; Cuesta-Frau, D.; Miro-Martinez, P.; Oltra-Crespo, S.; Vigil-Medina, L.; Varela-Entrecanales, M. A new algorithm for quadratic Sample Entropy optimization for very short biomedical signals: Application to blood pressure records. Comput. Methods Prog. Biomed. 2014, 114, 231–239. [Google Scholar]
Figure 1. Graphical example of the process involved in the computation of α. The horizontal axis corresponds to the log scale of length values. The vertical axis corresponds to log values calculated for fluctuation F for different lengths. The dotted line represents the least squares fitted line.
Figure 1. Graphical example of the process involved in the computation of α. The horizontal axis corresponds to the log scale of length values. The vertical axis corresponds to log values calculated for fluctuation F for different lengths. The dotted line represents the least squares fitted line.
Entropy 16 05901f1
Figure 2. EEG and PSD for one signal of each group. (a) Data A, control subject with open eyes; (b) Data B, control subject with closed eyes; (c) Data C, epileptical subject, between seizures (interictal); (d) Data D, epileptical subject, between seizures (interictal); (e) Data E, epileptical subjet, during seizure (ictal).
Figure 2. EEG and PSD for one signal of each group. (a) Data A, control subject with open eyes; (b) Data B, control subject with closed eyes; (c) Data C, epileptical subject, between seizures (interictal); (d) Data D, epileptical subject, between seizures (interictal); (e) Data E, epileptical subjet, during seizure (ictal).
Entropy 16 05901f2
Table 1. Results obtained for EEG signals rearranged in control and epileptic classes, using a random sample removal approach. Values in bold characters correspond to cases where the associated entropy measure was not able to distinguish between the two groups.
Table 1. Results obtained for EEG signals rearranged in control and epileptic classes, using a random sample removal approach. Values in bold characters correspond to cases where the associated entropy measure was not able to distinguish between the two groups.
Metric0%10%30%50%70%90%
ApEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
SampEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
DFAp = 0.001p = 0.001p = 0.001p = 0.074p = 0.004p = 0.006
FuzzyEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
Table 2. Results obtained for PT and OT records treated with encainide, using a random sample removal approach. Values in bold characters correspond to cases where the associated entropy measure was not able to distinguish between the two groups.
Table 2. Results obtained for PT and OT records treated with encainide, using a random sample removal approach. Values in bold characters correspond to cases where the associated entropy measure was not able to distinguish between the two groups.
Metric0%10%30%50%70%90%
ApEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.003p = 0.002
SampEnp = 0.293p = 0.439p = 0.568p = 0.574p = 0.929p = 0.586
DFAp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
FuzzyEnp = 0.001p = 0.001p = 0.001p = 0.002p = 0.001p = 0.002
Table 3. Results obtained for pathologic ALS gait records versus control records, using a random sample removal approach. Values in bold characters correspond to cases where the associated entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Table 3. Results obtained for pathologic ALS gait records versus control records, using a random sample removal approach. Values in bold characters correspond to cases where the associated entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Metric0%10%30%50%70%90%
ApEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
SampEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.003p = 0.001
DFAp = 0.001p = 0.004NANANANA
FuzzyEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.002
Table 4. Results obtained for pathologic PD gait records versus control records, using a random sample removal approach. Values in bold characters correspond to cases where the associated entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Table 4. Results obtained for pathologic PD gait records versus control records, using a random sample removal approach. Values in bold characters correspond to cases where the associated entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Metric0%10%30%50%70%90%
ApEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
SampEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.160
DFAp = 0.001p = 0.001NANANANA
FuzzyEnp = 0.088p = 0.098p = 0.005p = 0.004p = 0.001p = 0.001
Table 5. Results obtained for pathologic HD gait records versus control records, using a random sample removal approach. Values in bold characters correspond to cases where the associated entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Table 5. Results obtained for pathologic HD gait records versus control records, using a random sample removal approach. Values in bold characters correspond to cases where the associated entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Metric0%10%30%45%70%90%
ApEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
SampEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
DFAp = 0.001p = 0.842NANANANA
FuzzyEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
Table 6. Results obtained for EEG signals rearranged in control and epileptic classes, using a uniform sample removal approach. Values in bold characters correspond to cases where the corresponding entropy measure was not able to distinguish between the two groups.
Table 6. Results obtained for EEG signals rearranged in control and epileptic classes, using a uniform sample removal approach. Values in bold characters correspond to cases where the corresponding entropy measure was not able to distinguish between the two groups.
Metric0%10%30%50%70%90%
ApEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
SampEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
DFAp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
FuzzyEnp = 0.001p = 0.001p = 0.001p = 0.002p = 0.001p = 0.002
Table 7. Results obtained for PT and OT records treated with encainide, using a uniform sample removal approach. Values in bold characters correspond to cases where the corresponding entropy measure was not able to distinguish between the two groups.
Table 7. Results obtained for PT and OT records treated with encainide, using a uniform sample removal approach. Values in bold characters correspond to cases where the corresponding entropy measure was not able to distinguish between the two groups.
Metric0%10%30%50%70%90%
ApEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
SampEnp = 0.051p = 0.251p = 0.365p = 0.270p = 0.237p = 0.055
DFAp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
FuzzyEnp = 0.001p = 0.001p = 0.001p = 0.002p = 0.001p = 0.002
Table 8. Results obtained for pathologic gait records from ALS patients versus control records (percentage of right stance interval measures in double support interval), using a uniform sample removal approach. Values in bold characters correspond to cases where the corresponding entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Table 8. Results obtained for pathologic gait records from ALS patients versus control records (percentage of right stance interval measures in double support interval), using a uniform sample removal approach. Values in bold characters correspond to cases where the corresponding entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Metric0%10%30%45%70%90%
ApEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
SampEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
DFAp = 0.001p = 0.002NANANANA
FuzzyEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.101p = 0.389
Table 9. Results obtained for pathologic gait records from PD patients versus control records (percentage of right stance interval measures in double support interval), using a uniform sample removal approach. Values in bold characters correspond to cases where the corresponding entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Table 9. Results obtained for pathologic gait records from PD patients versus control records (percentage of right stance interval measures in double support interval), using a uniform sample removal approach. Values in bold characters correspond to cases where the corresponding entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Metric0%10%30%45%70%90%
ApEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.003p = 0.041
SampEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
DFAp = 0.001p = 0.001NANANANA
FuzzyEnp = 0.088p = 0.151p = 0.799p = 0.935p = 0.001p = 0.001
Table 10. Results obtained for pathological gait records from HD patients versus control records (percentage of right stance interval measures in double support interval), using a uniform sample removal approach. Values in bold characters correspond to cases where the corresponding entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Table 10. Results obtained for pathological gait records from HD patients versus control records (percentage of right stance interval measures in double support interval), using a uniform sample removal approach. Values in bold characters correspond to cases where the corresponding entropy measure was not able to distinguish between the two groups. NA corresponds to cases where not enough samples were available for the calculations.
Metric0%10%30%45%70%90%
ApEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.0010.056
SampEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.001
DFAp = 0.001p = 0.064NANANANA
FuzzyEnp = 0.001p = 0.001p = 0.001p = 0.001p = 0.001p = 0.209

Share and Cite

MDPI and ACS Style

Cirugeda-Roldan, E.; Cuesta-Frau, D.; Miro-Martinez, P.; Oltra-Crespo, S. Comparative Study of Entropy Sensitivity to Missing Biosignal Data. Entropy 2014, 16, 5901-5918. https://doi.org/10.3390/e16115901

AMA Style

Cirugeda-Roldan E, Cuesta-Frau D, Miro-Martinez P, Oltra-Crespo S. Comparative Study of Entropy Sensitivity to Missing Biosignal Data. Entropy. 2014; 16(11):5901-5918. https://doi.org/10.3390/e16115901

Chicago/Turabian Style

Cirugeda-Roldan, Eva, David Cuesta-Frau, Pau Miro-Martinez, and Sandra Oltra-Crespo. 2014. "Comparative Study of Entropy Sensitivity to Missing Biosignal Data" Entropy 16, no. 11: 5901-5918. https://doi.org/10.3390/e16115901

Article Metrics

Back to TopTop