Next Article in Journal
Cryptanalysis and Security Improvements of ‘Two-Factor User Authentication in Wireless Sensor Networks’
Next Article in Special Issue
Environmentally Sensitive Fluorescent Sensors Based on Synthetic Peptides
Previous Article in Journal
Dynamical Jumping Real-Time Fault-Tolerant Routing Protocol for Wireless Sensor Networks
Previous Article in Special Issue
Fluorescent Silicate Materials for the Detection of Paraoxon
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Near-Infrared Fluorescence Detection of Acetylcholine in Aqueous Solution Using a Complex of Rhodamine 800 and p-Sulfonato-calix[8]arene

WPI Immunology Frontier Research Center, Osaka University, Yamada-oka, 1-3, Suita, Osaka 565-0871, Japan
Sensors 2010, 10(3), 2438-2449; https://doi.org/10.3390/s100302438
Submission received: 18 February 2010 / Revised: 4 March 2010 / Accepted: 9 March 2010 / Published: 23 March 2010
(This article belongs to the Special Issue Fluorescent Chemosensors)

Abstract

:
The complexing properties of p-sulfonatocalix[n]arenes (n = 4: S[4], n = 6: S[6], and n = 8: S[8]) for rhodamine 800 (Rh800) and indocyanine green (ICG) were examined to develop a near-infrared (NIR) fluorescence detection method for acetylcholine (ACh). We found that Rh800 (as a cation) forms an inclusion complex with S[n], while ICG (as a twitter ion) have no binding ability for S[n]. The binding ability of Rh800 to S[n] decreased in the order of S[8] > S[6] >> S[4]. By the formation of the complex between Rh800 and S[8], fluorescence intensity of the Rh800 was significantly decreased. From the fluorescence titration of Rh800 by S[8], stoichiometry of the Rh800-S[8] complex was determined to be 1:1 with a dissociation constant of 2.2 μM in PBS. The addition of ACh to the aqueous solution of the Rh800-S[8] complex caused a fluorescence increase of Rh800, resulting from a competitive replacement of Rh800 by ACh in the complex. From the fluorescence change by the competitive fluorophore replacement, stoichiometry of the Rh800-ACh complex was found to be 1:1 with a dissociation constant of 1.7 mM. The effects of other neurotransmitters on the fluorescence spectra of the Rh800-S[8] complex were examined for dopamine, GABA, glycine, and l-asparatic acid. Among the neurotransmitters examined, fluorescence response of the Rh800-S[8] complex was highly specific to ACh. Rh800-S[8] complexes can be used as a NIR fluorescent probe for the detection of ACh (5 × 10−4−10−3 M) in PBS buffer (pH = 7.2).

Graphical Abstract

1. Introduction

Acetylcholine (ACh) is one of the most abundant neurotransmitters in the nervous system [1]. ACh acts as a transmitter at synapses in the ganglia of the visceral motor system, and at a variety of sites within the central nervous system. After the binding to ACh receptors at postsynaptic membranes, ACh is rapidly hydrolyzed to choline and acetic acids by ACh esterase to prevent over-accumulation of ACh. The concentration of ACh in the synaptic cleft of an active neuromuscular junction is about 5 × 10−4 M [2]. There are many methods for measuring the concentration of ACh: GC-MS [3] and HPLC with chemiluminescence assay [4,5], colorimetric assay [6], and radioimmunoassay [7,8]. Recently, electrochemical methods using ACh esterase-modified electrodes have been developed [9,10]. However, these methods involve some complicated and time-consuming procedures, and require expensive equipments. The objective of this work is to develop a facile fluorescence detection method for ACh in the near-infrared (NIR) region.
Compared to optical sensing using absorption, fluorescence sensing is simple and highly sensitive, because fluorescence intensity is measured directly without comparison with a reference [11]. By using a conventional spectrofluorometer, the concentration (μM−nM) of fluorescent molecules in aqueous solution can be easily determined. However, fluorescence sensing in biological samples has some complicated problem concerning light absorption and scattering. For example, in living tissues, there are many intrinsic chromophores like hemoproteins and flavin-containing proteins that absorb or emit visible light [11,12]. In contrast, NIR light ranging from 700 nm to 1100 nm is useful for in vivo fluorescence sensing. In living tissues, the absorption coefficient of NIR light is much lower than that of visible light, and the scattering of NIR light is much smaller than that of visible light [13,14].
In this paper, we report a NIR fluorescence detection method for ACh using a complex of Rh800 and S[8]. So far, it has been shown that S[n] have binding abilities for quaternary ammonium cations [1519], and they are able to recognize ACh in aqueous solution [2027]. Koh et al. first reported the utility of the complex of S[6] and a fluorescent ACh analog for the detection of ACh in aqueous solution [21]. Previously, we reported that S[8] strongly binds to fluorescent ACh analogs with cationic charges, dansylcholine [23] and rhodamine 6G [27] in aqueous solution, and their fluorescence can be used for the detection of 10−4 M levels of ACh in aqueous solution. Recently, Korbakov et al. [26] have reported ACh detection at micromolar concentrations by use of the complex between a cationic fluorescent guest, trans-4-[4-(dimethylamino)styryl]-1-methylpyridium p-toluensulfonate with S[6]. All of these methods, however, are limited to fluorescence detection of ACh in the visible region. To the best of our knowledge, there are no reports of NIR fluorescent probes for detecting ACh in aqueous solutions.
To develop a NIR fluorescence detection method for ACh, we examined complexing properties of NIR fluorescent dyes (Rh800 and ICG) for S [n] in aqueous solution (Scheme 1). We found that Rh800 has a strong binding ability to S[8], while ICG shows no binding ability to S[n]. The formation of Rh800-S[n] complex and the competitive binding of ACh to Rh800-S[8] complex were examined by fluorescence titration experiments. The binding selectivity of the Rh800-S[8] complex was quite specific to ACh among other neurotransmitters such as dopamine, GABA, and glycine. We demonstrate the utility of Rh800-S[8] complex as a NIR fluorescent probe for determining ACh concentration (5 × 10−4−10−3 M) in aqueous solutions.

2. Results and Discussion

2.1. Fluorescence Properties of Rh800 and ICG

We have chosen Rh800 and ICG as guest NIR fluorophores for S[n]. Rh800 is one of the few rhodamines that have NIR fluorescence, and it has been used as a laser dye [28]. Recently, Rh800 was also used as a mitochondrial membrane potential sensitive dye [29]. ICG is a most popular NIR dye and is used for medical diagnostics such as hepatic function, liver blood flow, and for ophthalmic angiography [30,31]. Rh800 has a cationic charge, and ICG has no net charge with a twitter ion (Scheme 1).
Figure 1 shows the emission and excitation spectra of Rh800 and ICG in PBS buffer. Rh800 emits at about 710 nm in PBS. ICG has an emission peak at about 800 nm and can be excited by NIR-light (circa700 nm–800 nm). It has been reported that fluorescence life times of Rh800 and ICG are less than 1 ns in aqueous solutions [32,33], and the fluorescence efficiency of these NIR-dyes is much lower than that of fluorescence dyes such as rhodamine 6G and fluorescein in the visible region [30]. Since there are no suitable quantum yield (QY) standards in the NIR region, we used an absolute QY measurement method (see, experimental section) for determining QYs of the NIR-dyes: 3.8 % for Rh800 (in PBS) and 0.5 % for ICG (in water).

2.2. The Complexing Abilities of Rh800 and ICG for S[n]

To examine the complexing abilities of Rh800 and ICG, we measured their fluorescence spectra in the presence of S[n]. Since it is well known that S[8] strongly binds to rhodamine 6G [27] and rhodamine B [22], we first examined the effects of S[8] on the fluorescence spectra of Rh800 and ICG. (Figure 2). The fluorescence of Rh800 was quenched by S[8]. However, the fluorescence of Rh800 was not completely diminished even with the addition of excess amounts of S[8]. To gain insight for the quenching mechanism [34] for Rh800, we measured the temperature dependence of the fluorescence quenching by S[8]. The Stern-Volmer plots at 25 °C and 50 °C are shown as an inset in Figure 2a. It should be noted that Rh800 is quenched more effectively at lower temperature. This result indicates that the fluorescence quenching of Rh800 dose not result from the dynamic (collisional) interaction between Rh800 and S[8]. In the case of ICG, fluorescence changes were not observed by addition of S[8], indicating that ICG (as a twitter ion) has no binding ability to S[8]. This result is consistent with our previously reported result [23] that a cationic fluorescent ACh analog, dansylcholine binds to S[8], while a neutral fluorescent ACh analog, dansylsulfoamide does not bind to S[8].
Figure 3 shows changes in the relative fluorescence intensity of Rh800 upon adding S[n]. The fluorescence quenching of Rh800 by S[n] was significantly affected by the size of S[n]. Even at the presence of 1,300 equivalents of S[4], fluorescence intensity of the Rh800 was not changed. In contrast, the addition of S[6] and S[8] significantly quenched the fluorescence intensity of Rh800. The excess amounts of S[6] and S[8] decreased the fluorescence intensity of Rh800 by a factor of 40 % and 70%, respectively. This size dependency suggests that the quenching of Rh800 results from the static interaction (complex formation) between Rh800 and S[n], but not from the collisional interaction between Rh800 and S[n]. Assuming that Rh800 forms a 1:1 complex with S[n], the dissociation constants (Kd) of Rh800-S[n] complex can be rationalized to the fluorescence intensity change (ΔF) in the presence of excess amounts of S[n]:
1 Δ F = 1 c + K d c [ S [ n ] ]
where c is a constant. As can be seen from Figure 3b, the plots of 1/ΔF versus [S[n]] shows linear relationships, indicating that S[n] (n = 6 and 8) forms a 1:1 complex with Rh800. The dissociation constants are determined to be 9.5 μM and 2.2 μM for the Rh800 complex with S[6] and S[8], respectively. This result shows that the binding affinity of Rh800 to S[8] is about four-times larger than that of Rh800 to S[6]. In the case of S[4], the binding affinity of Rh800 to S[4] is very low to determine the dissociation constant.

2.3. Fluorescence Detection of ACh Using Rh800-S[8] Complex

Figure 4a shows the fluorescence change of Rh800 in the aqueous solution of Rh800-S[8] complex upon adding ACh. The fluorescence intensity of Rh800 significantly increased with increasing ACh concentration. The inset shows the dependence of the relative fluorescence intensity of Rh800 at 710 nm on the ACh concentration. This result shows that the fluorescence changes in the Rh800-S[8] complex solution can be used for the detection of ACh in aqueous solution. The increase in the fluorescence intensity of Rh800 is explained by the competitive displacement of Rh800 by ACh:
[ Rh 800 S [ 8 ] ]   + n ACh                 [ n ACh S [ 8 ] ]   + Rh 800
In the presence of excess amounts (500 equiv.) of ACh over Rh800, the intensity of Rh800 increased by a factor of 87%. The inset graph indicates that the detection limit (10% fluorescence change) of ACh is circa 5 × 10−4 M. In the competitive replacement reaction, the dissociation constant (KRh800) for the Rh800-S[8] complex can be rationalized to the dissociation constant (KACh) for the ACh-S[8] complex as follows:
α ( [ S [ 8 ] ] ( 1 α ) [ Rh 800 ] ( 1 α ) K Rh 800     =     [ ACh ] n K ACh ,                     α = ( F F o ) ( F F o )
where Fo, F, and F are the fluorescence intensity of the Rh800 before, during, and after the titration with ACh in large excess amounts. Figure 4b shows plots of f (=α([S[8]]-(1−α)[Rh800])/(1−α)KRh800) versus [ACh] or [ACh]2. When n is set to 1, the plot shows a linear relationship, indicating that one ACh molecule is replaced by one Rh800 molecule in the Rh800-S[8] complex. From the slope of the plot, the value of KACh for the ACh-S[8] complex is determined to be 1.7 mM.

2.4. Detection Selectivity of Rh800-S[8] Complex

To check the detection selectivity of the Rh800-S[8] complex, we first examined the effects of ACh, dopamine, and GABA on the fluorescence intensity of the Rh800-S[8] complex. Dopamine is one of monoamine neurotransmitters that have cation charges similar to ACh [35]. GABA (γ-aminobutyric acid) is the chief inhibitory neurotransmitter in the central nerve system [36]. GABA is a kind of amino acids with no net charge. We measured the time course of the fluorescence intensity of the Rh800-S[8] solution upon addition of ACh, dopamine, and GABA. The fluorescence intensity of Rh800 responded to the successive additions of ACh as shown in Figure 5a. In contrast, the addition of dopamine and GABA up to 7.7 mM did not change the fluorescence intensity of Rh800 (Figure 5b and 5c). The effect of ACh on the Rh800 fluorescence was also examined in the presence of 5.5 mM of dopamine. As shown in Figure 5d, the fluorescence response of Rh800 for ACh was not hampered by dopamine. These results show that the fluorescence response of Rh800-S[8] complex is sensitive to ACh compared to dopamine and GABA.
We further examined fluorescence responses of the Rh800-S[8] complex for other neurotransmitters (glysine and l-asparatic acid), basic amino acids, ammonium chloride, and choline. The results including ACh, dopamine, and GABA are summarized in Figure 6. Among the neurotransmitters examined, ACh was most sensitive to change in the fluorescence intensity of Rh800. In the presence of ACh, the fluorescence intensity was increased by a factor of 87%. Choline also increased the fluorescence intensity by a factor of 70%. Other neurotransmitters such as dopamine, GABA, glycine, and l-asparatic acid scarcely affected the fluorescence intensity of Rh800-S[8] solution. Basic amino acids with cationic charges (l-histidine and l-lysine) slightly increased the fluorescence intensity of the Rh800-S[8] solution, while ammonium chloride did not affect its fluorescence intensity. These results indicate that hydrophobic interaction and electrostatic interaction play important roles in the formation of complex between S[8] and ACh. The strong binding ability of S[8] for choline implies that the quaternary ammonium moieties of ACh and choline are recognized by the π-basic cavity [16,20,23] of S[8].
In the view of biological application, the detection selectivity of ACh over choline is very important because ACh is rapidly hydrolyzed to choline and acetic acids by acetylcholineesterase in vivo. Unfortunately, the Rh800-S[8] complex cannot distinguish between ACh and choline. Thus, for using Rh800-S[8] complex as a fluorescent ACh probe in biological samples, it would be necessary to perform microwave deactivation [37] of acetylcholineesterase to prevent the hydrolysis of ACh.

3. Experimental Section

3.1. Materials

p-Sulfonatocalix[4]arene (S[4]), p-sulfonatocalix[6]arene (S[6]), indocyanine greeen (ICG) were purchased from Tokyo Organic Chemicals (Japan). p-Sulfonatocalix[8]arene (S[8]) was purchased from Dojin Chemicals (Japan). Acetylcholine chloride, dopamine hydrochloride were purchase from Wako Chemicals (Japan). Rhodamine 800 (Rh800) was purchased from Anaspec. Other chemicals used are analytical grade.

3.2. Fluorescence Spectra and Quantum Yield Measurements

Fluorescence spectra were measured on a FP-6200 spectrofluorometer (Jasco) using a quarts cuvette (1 cm × 1 cm × 4.5 cm), where excitation wavelength was set to 610 nm for Rh800 and 725 nm for ICG. Emission efficiencies of NIR-dyes in PBS were evaluated by using an absolute quantum yield measurement system (C10027, Hamamatsu Photonic). The absolute quantum yield (QY) is defined as QY = PNem/PNab, where PNem and PNab are the number of emitted and absorbed photons by fluorescence materials. Excitation wavelengths were set to 610 nm for Rh800and 725 nm for ICG. The concentration of the NIR dyes was 1 μM.

3.3. Fluorescence Titration of NIR Dyes by S[n]

Rh800 and ICG were dissolved in PBS and their concentrations were set to 40 nM. To 3 mL of the NIR-dye solution, microliter aliquots of aqueous solution f S[n] (1 mM) were added under stirring. After stirring for 2 min, fluorescence spectra of the NIR dye were measured.

3.4. Competitive Fluorophore Displacement by ACh in the Complex of R800-S[n]

To 3 mL of Rh800 solution (40 nM/PBS), 100 μL of S[n] (1 mM) was added. To this solution, microliter aliquots of ACh (350 mM) were added under stirring. After 2 min stirring, fluorescence spectra were measured. For the competitive fluorophore displacement by other neurotransmitters, amino acids, ammonium chloride, and choline, similar procedure as the above method was applied.

4. Conclusions

In conclusion, we have developed a new ACh detection method using NIR fluorescence of the Rh800-S[8] complex. The competitive fluorophore displacement by ACh in the Rh800-S[8] complex caused significant increase in the NIR fluorescence intensity of Rh800. The detection limit of ACh in this method was about 5 × 10−4 M. Fluorescence response of the Rh800-S[8] complex was highly specific to ACh over other neurotransmitters such as dopamine, GABA, glysine, and l-asparatic acid. Using the Rh800-S[8] complex as a fluorescent probe, ACh could be detected by NIR-fluorescence at 710 nm. To the best of our knowledge, this is a first report of a NIR-fluorescence detection of ACh in aqueous solution. Unfortunately, our NIR detection system cannot discriminate ACh and choline, because p-sulfonatocalix[8]arene has poor binding selectivity for ACh over choline. In addition, the detection limit (5 × 10−4 M) of ACh is not enough to measure ACh concentration in biological samples. Thus, for practical application of our ACh detection method for biological systems, detection selectivity and sensitivity for ACh should be improved.

Acknowledgments

This work was partly supported by the Ministry of Education, Science, Sport, and Culture of Japan (Grant-in-Aid for Scientific Research, No. 19550157).

References and Notes

  1. Augustine, G.J.; Fritzpatrick, D.; Hall, W.C.; LaMantia, A.-S.; MaNamara, J.O.; Mooney, R.D.; Platt, M.L.; Purves, D.; Simon, S.A.; White, L.E.; Williams, S.M.; Winstein, S.; Henderson, R.B. NeuroScienec; Purves, D., Augustine, G.J., Fritzpatrick, D., Hall, W.C., LaMantia, A.-S., MaNamara, J.O., White, L.E., Eds.; Sinauer: Sunderland, MA, USA, 2008; Chapter 6; pp. 119–126. [Google Scholar]
  2. Albert, B.; Johnson, A.; Lewis, J.; Laff, M.; Roberts, K.; Walter, P. Molecular Biology of the Cell, 5th ed; Garland Science: New York, NY, USA, 2008; Chapter 15; p. 882. [Google Scholar]
  3. Honda, K.; Kunihara, M.; Maruyama, Y. Determination of picomole amounts of choline and acetylcholine in blood by gas chromatography-mass spectrometry equipped with a newly improved pyrolyzer. J. Chromatogr. A 1982, 239, 335–342. [Google Scholar]
  4. Honda, K.; Miyaguchi, K.; Nishino, H.; Tanaka, H.; Yao, T.; Imai, K. High-performance liquid chromatography followed by chemiluminescence detection of acetylcholine and choline utilizing immobilized enzymes. Anal. Biochem 1986, 153, 50–53. [Google Scholar]
  5. Ricny, J.; Coupek, J.; Tucek, S. Determination of acetylcholine and choline by flow injection with immobilized enzymes and fluorometric or luminometric detection. Anal. Biochem 1989, 170, 221–227. [Google Scholar]
  6. Hestrin, S. The reaction of acetylcholine and other carboxylic acid derivatives with hydroxylamine, and its analytical application. J. Biol. Chem. 1949, 180, 249–261. [Google Scholar]
  7. Schuberth, J.; Sparf, B.; Sundwall, A. A technique for the study of acetylcholine turnover in mouse brain in vivo. J. Neurochem 1969, 16, 695–700. [Google Scholar]
  8. Feigenson, M.E.; Saeleus, J.K. An enzyme assay for acetylcholine. Biochem. Pharmacol 1969, 18, 1479–1486. [Google Scholar]
  9. Snejdarkova, M.; Svobodova, L.; Evtugyn, G.; Budnikov, H.; Karyakin, A.; Nikolelis, D.P.; Hianik, T. Acetylcholineesterase sensors based on gold electrodes modified with dendrimer and polyaniline A comparative research. Anal. Chem. Acta 2004, 514, 79–88. [Google Scholar]
  10. Shibli, S.M.A.; Beenakumari, K.S.; Suma, N.D. Nano nickel oxide/nickel incorporated nickel composite coating for sensing and estimation of acetylcholine. Biosens. Bioelectron 2006, 22, 633–638. [Google Scholar]
  11. Lakowicz, J.R. Principles of Fluorescence Spectroscopy, 3rd ed.; Springer: New York, NY, USA, 2006; Chapter 23; pp. 623–674. [Google Scholar]
  12. Weissleder, R.A. A clearer vision for in vivo imaging. Nat. Biotechnol 2001, 19, 316–317. [Google Scholar]
  13. Liu, H.; Beauvoit, B.; Kimura, M.; Chance, B. Dependence of tissue optical properties on solute-induced changes in refractive index and osmolarity. J. Biomed. Opt 1996, 1, 200–211. [Google Scholar]
  14. Lim, Y.T.; Kim, S.; Nakayama, A.; Stott, N.E.; Bawendi, M.G.; Frangioni, J.V. Selection of quantum dot wavelengths for biomedical assays and imaging. Mol. Imaging 2003, 2, 50–64. [Google Scholar]
  15. Shinkai, S.; Araki, K.; Manabe, O. NMR determination of association constants for calixarene complexes. Evidence for the formation of a 1:2 complex with calix[8]arene. J. Am. Chem. Soc 1988, 110, 7214–7215. [Google Scholar]
  16. Shinkai, S.; Araki, K.; Matsuda, T.; Nishiyama, N.; Ikeda, H.; Takasu, I.; Iwamoto, M. NMR and crystallographic studies of a p-sulfonatocalix[4]arene-guest complex. J. Am. Chem. Soc 1990, 112, 9053–9058. [Google Scholar]
  17. Arena, G.; Casnati, A.; Contino, A.; Gulino, F.G.; Sciotto, D.; Ungaro, R. Entropic origin of the sulfonate groups’ electrostatic assistance in the complexation of quaternary ammonium cations by water soluble calix[4]arenes. J. Chem. Soc. Perkin Trans 2000, 2, 419–423. [Google Scholar]
  18. Aruduini, A.; Demuru, D.; Pochini, A.; Secchi, A. Recognition of quaternary ammonium cations by calix[4]arene derivatives supported on gold nanoparticles. Chem. Commun 2005, 5, 645–647. [Google Scholar]
  19. Wang, L.-H.; Guo, D.-S.; Chen, Y.; Liu, Y. Thermodynamics of interactions between organic ammonium ions and sulfonatocalixarenes. Thermoch. Acta 2006, 443, 132–135. [Google Scholar]
  20. Lehn, J.-M.; Meric, R.; Vigneron, J.-P.; Cerario, M.; Guilhem, J.; Pascard, C.; Asfari, Z.; Vicens, J. Binding of acetylcholine and other quaternary ammonium cations by sulfonated calixarenes. Crystal structure of a [choline-tetrasulfonated calix[4]arene] complex. Supramol. Chem 1995, 5, 97–103. [Google Scholar]
  21. Koh, K.N.; Araki, K.; Ikeda, A.; Otsuka, H.; Shinkai, S. Reinvestigation of calixarene-based artificial-signaling acetylcholine receptors useful in neutral aqueous (water-methanol) solution. J. Am. Chem. Soc 1996, 118, 755–758. [Google Scholar]
  22. Zhang, Y.-J.; Cao, W.-X.; Xu, J. Interaction of sulfonated calix[n]arenes with rhodamine B and its application to determine acetylcholine in a real neutral aqueous medium. Chin. J. Chem 2002, 20, 322–326. [Google Scholar]
  23. Jin, T. A new fluorometric method for the detection of the neurotransmitter acetylcholine in water using a dansylcholine complex with p-sulfonated calix[8]arene. J. Inclusion Phenom. Macrocyclic Chem 2003, 45, 195–201. [Google Scholar]
  24. Wang, L.-H.; Guo, D.-S.; Chen, Y.; Liu, Y. Thermodynamics of interactions between organic ammonium ions and sulfonatocalixarenes. Thermoch. Acta 2006, 443, 132–135. [Google Scholar]
  25. Bakirci, H.; Nau, W.M. Fluorescence regenerations as a signaling principle for choline and carnitine binding: a refined supramolecular sensor system based on a fluorescent azoalkane. Adv. Funct. Mater 2006, 16, 237–242. [Google Scholar]
  26. Korbakov, N.; Timmerman, P.; Lidich, N.; Urbach, B.; Sa’ar, A.; Yitzchaik, S. Acetylcholine detection at micromolar concentrations with the use of an artificial receptor-based fluorescence switch. Langmuir 2008, 24, 2580–2587. [Google Scholar]
  27. Jin, T.; Fujii, F.; Ooi, Y. Interfacial recognition of acetylcholine by an amphiphilc p-sulfonatocalix[8]arene derivative incorporated into dimyristoyl phosphatidylcholine vesicles. Sensors 2008, 8, 6777–6790. [Google Scholar]
  28. Rizvi, N.H.; Opalinska, M.M.; French, P.M.W.; Taylor, J.R. A cw rhodamine 800 dye laser passively mode-locked with neocyanine. Opt. Commun 1990, 80, 57–59. [Google Scholar]
  29. Jilkina, O.; Kong, H.-J.; Hwi, L.; Kuzio, B.; Xiang, B.; Manley, D.; Jackson, M; Kupriyanov, V.V. Interaction of a mitochondrial membrane potential-sensitive dye, rhodamine 800, with rat mitochondria, cells, and perfused hearts. J. biomed. Opt 2006, 11, 014009(1)–014009(9). [Google Scholar]
  30. Benson, R.C.; Kues, H.A. Fluorescence properties of indocyanine green as related to angiography. Phys. Med. Biol 1978, 23, 159–163. [Google Scholar]
  31. Saxena, V.; Sadoqi, M.; Shao, J. Degradation kinetics of indocyanine green in aqueous solution. J. Pharm. Sci 2003, 92, 2090–2097. [Google Scholar]
  32. Lee, H.; Berezin, M.Y.; Henary, M.; Strekowski, L.; Achiefu, S. Fluorescence lifetime properties of near-infrared cyanine dyes in relation to their structures. J. Photochem. Photobiol. A: Chem 2008, 200, 438–444. [Google Scholar]
  33. Abugo, O.O.; Nair, R.; Lakowicz, J.R. Fluorescence properties of rhodamine 800 in whole blood and plazma. Anal. Biochem 2000, 279, 142–150. [Google Scholar]
  34. Lakowicz, J.R. Principles of Fluorescence Spectroscopy, 3rd ed; Springer: New York, NY, USA, 2006; Chapter 8; pp. 278–282. [Google Scholar]
  35. Augustine, G.J.; Fritzpatrick, D.; Hall, W.C.; LaMantia, A.-S.; MaNamara, J.O.; Mooney, R.D.; Platt, M.L.; Purves, D.; Simon, S.A.; White, L.E.; Williams, S.M.; Winstein, S.; Henderson, R.B. NeuroScienec; Purves, D., Augustine, G.J., Fritzpatrick, D., Hall, W.C., LaMantia, A.-S., MaNamara, J.O., White, L.E., Eds.; Sinauer: Sunderland, MA, USA, 2008; Chapter 6; pp. 137–138. [Google Scholar]
  36. Augustine, G.J.; Fritzpatrick, D.; Hall, W.C.; LaMantia, A.-S.; MaNamara, J.O.; Mooney, R.D.; Platt, M.L.; Purves, D.; Simon, S.A.; White, L.E.; Williams, S.M.; Winstein, S.; Henderson, R.B. NeuroScienec; Purves, D., Augustine, G.J., Fritzpatrick, D., Hall, W.C., LaMantia, A.-S., MaNamara, J.O., White, L.E., Eds.; Sinauer: Sunderland, MA, USA, 2008; Chapter 6. [Google Scholar]
  37. Barnes, N.M.; Costall, B.; Fell, A.F.; Naylor, R. An HPLC assay procedure of sensitivity and stability for measurement of acetylcholine and choline in neuronal tissue. J. Pharm. Pharmacol 1987, 39, 727–731. [Google Scholar]
Figure 1. Emission and excitation spectra of Rh800 (red lines) and ICG (blue lines) in PBS. Solid and dotted lines shows emission and excitation spectra, respectively. The concentration of the fluorescent dyes was 40 nM.
Figure 1. Emission and excitation spectra of Rh800 (red lines) and ICG (blue lines) in PBS. Solid and dotted lines shows emission and excitation spectra, respectively. The concentration of the fluorescent dyes was 40 nM.
Sensors 10 02438f1
Figure 2. Fluorescence spectra of Rh800 (a) and ICG (b) upon adding S[8] in PBS. The concentration of Rh800 and ICG was 40 nM. Excitation wavelengths were set to 600 nm for Rh800 and 725 nm for ICG. [S[8]] = 0 μM (blue line), 1.7 μM (green line), 5.0 μM (yellow line), 11.5 μM (orange line), 24 μM (red line), and 52 μM (brown line).
Figure 2. Fluorescence spectra of Rh800 (a) and ICG (b) upon adding S[8] in PBS. The concentration of Rh800 and ICG was 40 nM. Excitation wavelengths were set to 600 nm for Rh800 and 725 nm for ICG. [S[8]] = 0 μM (blue line), 1.7 μM (green line), 5.0 μM (yellow line), 11.5 μM (orange line), 24 μM (red line), and 52 μM (brown line).
Sensors 10 02438f2
Figure 3. (a) Relative fluorescence intensity of Rh800 (40 nM in PBS) in the presence of S[n]. S[n] (1 mM) was added to the aqueous solution of Rh800 (40 nM) under stirring. (b) Plots of 1/ΔF versus 1/ [S[n]].
Figure 3. (a) Relative fluorescence intensity of Rh800 (40 nM in PBS) in the presence of S[n]. S[n] (1 mM) was added to the aqueous solution of Rh800 (40 nM) under stirring. (b) Plots of 1/ΔF versus 1/ [S[n]].
Sensors 10 02438f3
Figure 4. (a) Fluorescence spectra of the aqueous solution of Rh800-S[8] complex upon adding ACh. [Rh800] = 40 nM, [S[8]]/[Rh800] = 800, and [ACh]: a) 0 mM, b) 1.1 mM, c) 3.4 mM, d) 7.7 mM, e)12 mM, and f) 16 mM. Inset shows concentration dependence of ACh on the fluorescence intensity of Rh800. (b) Plots of f versus [ACh] and f versus [ACh]2.
Figure 4. (a) Fluorescence spectra of the aqueous solution of Rh800-S[8] complex upon adding ACh. [Rh800] = 40 nM, [S[8]]/[Rh800] = 800, and [ACh]: a) 0 mM, b) 1.1 mM, c) 3.4 mM, d) 7.7 mM, e)12 mM, and f) 16 mM. Inset shows concentration dependence of ACh on the fluorescence intensity of Rh800. (b) Plots of f versus [ACh] and f versus [ACh]2.
Sensors 10 02438f4
Figure 5. Time course of the fluorescence intensity of Rh800-S[8] solution upon adding (a) ACh, (b) dopamine, and (c) GABA. (d) Changes in the fluorescence intensity of the Rh800-S[8] solution by successive addition of dopamine and ACh. Aliquots of the neurotransmitters (350 mM) were added to the Rh800-S[8] solution. Fluorescence intensity was measured at 710 nm with excitation at 600 nm. [Rh800] = 40 nM, [S[8]]/[Rh800] = 800.
Figure 5. Time course of the fluorescence intensity of Rh800-S[8] solution upon adding (a) ACh, (b) dopamine, and (c) GABA. (d) Changes in the fluorescence intensity of the Rh800-S[8] solution by successive addition of dopamine and ACh. Aliquots of the neurotransmitters (350 mM) were added to the Rh800-S[8] solution. Fluorescence intensity was measured at 710 nm with excitation at 600 nm. [Rh800] = 40 nM, [S[8]]/[Rh800] = 800.
Sensors 10 02438f5
Figure 6. Fluorescence changes (ΔF at 710 nm) in Rh800-S[8] solution upon adding ACh, other neurotransmitters (dopamine, GABA, glysine, l-asparatic acid), basic amino acids (l-histidine, l-lysine), ammonium chloride, and choline. 100 μL of these chemicals (350 mM in water) was added to the Rh800-S[8] solution (3 mL), where [Rh800] = 40 nM and [S[8]]/[Rh800] = 800.
Figure 6. Fluorescence changes (ΔF at 710 nm) in Rh800-S[8] solution upon adding ACh, other neurotransmitters (dopamine, GABA, glysine, l-asparatic acid), basic amino acids (l-histidine, l-lysine), ammonium chloride, and choline. 100 μL of these chemicals (350 mM in water) was added to the Rh800-S[8] solution (3 mL), where [Rh800] = 40 nM and [S[8]]/[Rh800] = 800.
Sensors 10 02438f6
Scheme 1. Molecular structure of the p-sulfonatocalix[n]arenes (S[n]): acetylcholine (ACh), and the NIR-fluorescent dyes: rhodamine 800 (Rh800) and indocyanine green (ICG).
Scheme 1. Molecular structure of the p-sulfonatocalix[n]arenes (S[n]): acetylcholine (ACh), and the NIR-fluorescent dyes: rhodamine 800 (Rh800) and indocyanine green (ICG).
Sensors 10 02438f7

Share and Cite

MDPI and ACS Style

Jin, T. Near-Infrared Fluorescence Detection of Acetylcholine in Aqueous Solution Using a Complex of Rhodamine 800 and p-Sulfonato-calix[8]arene. Sensors 2010, 10, 2438-2449. https://doi.org/10.3390/s100302438

AMA Style

Jin T. Near-Infrared Fluorescence Detection of Acetylcholine in Aqueous Solution Using a Complex of Rhodamine 800 and p-Sulfonato-calix[8]arene. Sensors. 2010; 10(3):2438-2449. https://doi.org/10.3390/s100302438

Chicago/Turabian Style

Jin, Takashi. 2010. "Near-Infrared Fluorescence Detection of Acetylcholine in Aqueous Solution Using a Complex of Rhodamine 800 and p-Sulfonato-calix[8]arene" Sensors 10, no. 3: 2438-2449. https://doi.org/10.3390/s100302438

Article Metrics

Back to TopTop