Next Article in Journal
Information Theory Filters for Wavelet Packet Coefficient Selection with Application to Corrosion Type Identification from Acoustic Emission Signals
Previous Article in Journal
A Cabled Acoustic Telemetry System for Detecting and Tracking Juvenile Salmon: Part 1. Engineering Design and Instrumentation
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Cabled Acoustic Telemetry System for Detecting and Tracking Juvenile Salmon: Part 2. Three-Dimensional Tracking and Passage Outcomes

1
Pacific Northwest National Laboratory, P.O. Box 999, Richland, WA 99332, USA
2
U.S. Army Corps of Engineers, Portland District, P.O. Box 2946, Portland, OR 97208, USA
*
Author to whom correspondence should be addressed.
Sensors 2011, 11(6), 5661-5676; https://doi.org/10.3390/s110605661
Submission received: 30 March 2011 / Revised: 20 May 2011 / Accepted: 23 May 2011 / Published: 26 May 2011
(This article belongs to the Section Physical Sensors)

Abstract

: In Part 1 of this paper, we presented the engineering design and instrumentation of the Juvenile Salmon Acoustic Telemetry System (JSATS) cabled system, a nonproprietary sensing technology developed by the U.S. Army Corps of Engineers, Portland District (Oregon, USA) to meet the needs for monitoring the survival of juvenile salmonids through the hydroelectric facilities within the Federal Columbia River Power System. Here in Part 2, we describe how the JSATS cabled system was employed as a reference sensor network for detecting and tracking juvenile salmon. Time-of-arrival data for valid detections on four hydrophones were used to solve for the three-dimensional (3D) position of fish surgically implanted with JSATS acoustic transmitters. Validation tests demonstrated high accuracy of 3D tracking up to 100 m upstream from the John Day Dam spillway. The along-dam component, used for assigning the route of fish passage, had the highest accuracy; the median errors ranged from 0.02 to 0.22 m, and root mean square errors ranged from 0.07 to 0.56 m at distances up to 100 m. For the 2008 case study at John Day Dam, the range for 3D tracking was more than 100 m upstream of the dam face where hydrophones were deployed, and detection and tracking probabilities of fish tagged with JSATS acoustic transmitters were higher than 98%. JSATS cabled systems have been successfully deployed on several major dams to acquire information for salmon protection and for development of more “fish-friendly” hydroelectric facilities.

Graphical Abstract

1. Introduction

Despite advances in turbine design and dam operations, passage through turbines and spillways may injure or kill downstream-migrating juvenile salmon [16]. The design and operation of more fish-friendly hydroelectric facilities require reliable estimates of behavior, timing, and survival of the juvenile salmonids as they migrate downstream [710]. Three-dimensional (3D) position estimates of fish surgically implanted with acoustic transmitters can provide near-dam fish behavior and passage route-specific survival rates. In addition, 3D position estimates provide near-dam vertical distribution data required for other important turbine passage evaluation techniques such as blade-strike modeling [5,10].

Position estimation algorithms are used to locate a moving or stationary object using a reference sensor network. Different signals and sensors are selected depending on applications. The Global Positioning System (GPS) uses satellites to provide location estimates by measuring the time of arrival (TOA) of radio signals [11,12]. An underwater acoustic tracking system provides reliable location information of the sources by measuring TOA of acoustic pulses or calls from aquatic animals using a network of underwater hydrophones or receivers with known locations [13,14]. However, the basic principles underlying the two systems are the same except for different requirements for the TOA measurement and geometric configuration of the sensor network.

Underwater acoustic tracking has become a common technology for studying and monitoring the movement and behavior of aquatic animals [15,16]. Usually the absolute time required for the acoustic signal to travel from the source location to the hydrophone is unknown, so time of arrival differences (TOADs) are computed. For 3D source location estimation, a network of at least four hydrophones is required so that four unknown variables—the reference TOA and the three coordinates of the source location—can be solved using four quadratic (nonlinear) distance equations. When one component of the source location is derived from another method, such as a pressure or depth sensor, the minimum number of hydrophones required is then reduced to three. For two-dimensional (2D) source location, at least three hydrophones are required because there are three unknown variables [17]. When there are more hydrophones than the minimum requirement (i.e., with redundant hydrophones), this problem becomes an over-determined system [17,18].

Many researchers have investigated this nonlinear problem, and several solvers have been developed mathematically for different applications [1329]. Watkins and Schevill [13] first described the 3D position estimate problem using four hydrophones and developed a geometric method. Exact solutions in various forms were also discussed by Fang [22], Wahlberg et al. [15], Spiesberger and Fristrup [14], and Bucher and Misra [28]. However, an exact solution may not always be available due to the nonlinearity of the four distance equations, errors in TOA or TOAD measurements, errors in sound speed, and hydrophone location uncertainties. In such cases, it is necessary to consider it as an optimization problem and estimate the source location by minimizing the errors.

The most common approximation employs iterative Taylor-series methods or variant Newton-Gaussian methods, which linearize the equation using Taylor expansion and search for an approximate numerical solution iteratively by minimizing the least-square error [20]. Foy [20] produced accurate position estimates at reasonable signal-to-noise ratios (SNRs). However, the solution was very sensitive to the initial conditions. Chan and Ho [25] introduced an intermediate variable to transform the nonlinear distance equations into linear equations containing the new intermediate variable and the original unknown variables. The authors then used an approximate realization of the maximum likelihood estimator to find a noniterative and explicit solution and compared their results with those from iterative Taylor-series methods. They found improved accuracy and efficiency at relatively high SNR and small TOAD estimation errors. Wahlberg et al. [15] synthesized the methods proposed by Watkins and Schevill [13] and Spiesberger and Fristrup [14] and developed a general mathematical form for 2D and 3D systems and for both minimum number of receivers arrays and over-determined arrays. Au and Herzing [16] successfully tracked dolphins using a star geometry in which a four-receiver array was arranged as a symmetrical star. Chan et al. [30] improved their maximum likelihood (ML) algorithms by starting from ML functions instead of linearizing the equations first, then derived a closed-form approximate maximum likelihood algorithm. The authors demonstrated the new method’s superior performance in 2D experiments.

In Part 1 of this paper [31], we presented the engineering design and instrumentation of the Juvenile Salmon Acoustic Telemetry System (JSATS) cabled system, a nonproprietary sensing technology developed by the U.S. Army Corps of Engineers, Portland District (OR, USA). All hydrophones are synchronized to the universal GPS clock using a GPS card (Model GPS170 PCI, Meinberg Funkuhren GmbH & Co. KG, Bad Pymont, Germany), resulting in detection time accuracy on a single system to 250 ns and across multiple systems to 500 ns. In addition, all JSATS components are required to pass comprehensive acceptance and performance tests in a controlled environment before they are deployed in the field [31,32]. Part 2 of this paper describes how the JSATS cabled system was employed and evaluated in the field as a reference sensor network for detecting and tracking juvenile salmon.

The efficiencies of exact solvers are approximately 90% possibly because of the high accuracy of clock management, hydrophone location survey, and improved performance of JSATS components. Therefore, only the performance of exact solvers is presented in this paper.

2. Methods

2.1. Study Site

The John Day Dam, owned and operated by the U.S. Army Corps of Engineers, is located on the Columbia River at river kilometer (rkm) 348, approximately 45 km east of the city of The Dalles, Oregon (Figure 1). The dam consists of a powerhouse, spillway, and navigation lock, with fish ladders at either end of the dam. The powerhouse is 602 m long and consists of 16 turbines with nameplate capacity of 135 MW each and overload capacity of 155.3 MW each. The spillway has an overall length of 374 m and contains 20 gates, each 15.2 m wide. Two prototype top-spill weirs (TSWs) were installed at spillbays 15 and 16 during 2008.

2.2. Algorithm

Consider a transmitting source in a four-hydrophone array. Throughout this section, the boldface letters indicate matrices or vectors. The source (S) and receiver (r) position vectors are defined as:

S = ( s x , s y , s z ) T r i = ( x i , y i , z i ) T i = 0 , 1 , 2 , 3

The distance between transmitting source and hydrophones gives:

( s x x i ) 2 + ( s y y i ) 2 + ( s z z i ) 2 = c 2 ( t i + T 0 ) 2 , i = 0 , 1 , 2 , 3
where c is the speed of sound, T0 is the time of travel from the source to the reference receiver (receiver 0), and ti is the TOAD between receiver i and the reference receiver. With ti measured by the common clock, the source position vector and T0 are the four unknowns.

Assuming the first receiver is located at the origin of the coordinate system and subtracting Equation (2) for i = 0 from Equation (2) for i = 1, 2, and 3 [14,15], we obtain:

2 R T S + 2 c 2 t T 0 = b
where:
R = [ x 1 x 2 x 3 y 1 y 2 y 3 z 1 z 2 z 3 ] , t = ( t 1 t 2 t 3 ) , b = ( b 1 b 2 b 3 ) , and b i = || r i || 2 c 2 t i 2

From Equation (3):

S = R T ( 1 2 b c 2 t T 0 )

Substituting Equation (4) into S T S = c 2 T 0 2 gives:

T 0 = p ± p 2 a q a
a = c 4 t T R 1 R T t c 2 , p = 1 2 c 2 t T R 1 R T b , and q = 1 4 b T R 1 R T b

Note that there are two possible solutions for T0. If both are complex, there is no solution for the given configuration and TOADs. A negative T0 is not possible. When there are two real non-negative solutions, then both provide possible locations for the source. It is then necessary to identify which one is physically possible. After T0 is determined, the source position (S) is obtained by Equation (4).

For this study, all hydrophones were installed at the dam face and looking upstream into the dam forebay. In addition, the hydrophones were baffled with plastic cones lined with an anechoic material to exclude loud noises emanating from structures downstream of the hydrophones. Therefore, the physical solution from two real non-negative solutions would be upstream of the dam. When more than four hydrophones detected the same transmitter message, the four with the optimum geometric configuration for 3D tracking were selected using the criteria developed by Wahlberg et al. [15] and Ehrenberg and Steig [33].

After the source location was obtained from 3D tracking, TOADs (t1, t2, t3) and T0 were computed using the estimated source location for the given hydrophone locations and speed of sound. Speed of sound was calculated using an equation developed by Marczak [34]. The total time error was then defined as:

Δ T = ( t 1 t 1 ) 2 + ( t 2 t 2 ) 2 + ( t 3 t 3 ) 2 + ( T 0 T 0 ) 2

The detailed steps for 3D tracking and passage outcomes for this study are as follows:

  • Pool all detections of the same signal from different hydrophones. If more than four hydrophones detect the same tag signal, select the four with the best geometric configuration for 3D tracking. Compute the TOAD directly from detection time because all hydrophones are synchronized to a universal GPS clock with accuracy within 0.5 μs.

  • Apply tracking solvers to estimate 3D locations and output solutions that are physical and within the prespecified ΔT (10 μs in this study).

  • Apply order 3 median filtering [35] to remove spurious locations and smooth fish tracks. Assign a route of passage based on the along-dam component of the last tracked location.

  • Assign another set of passage routes based on the detections of the last two hydrophones at different piers. For example, if the two hydrophones were at Pier 1 (numbering starting from the Oregon side) and Pier 2, then the passage route would be assigned to the first turbine unit.

  • Compare the two sets of passage routes. If the difference for a fish is more than one bay, check its trajectory and detection history manually.

2.3. Validation and Test Cases

To assess the accuracy of the deployed hydrophone arrays and validate tracking solvers, several tests were conducted using acoustic transmitters with GPS receivers fixed at various locations or drifting upstream of the John Day Dam powerhouse (PH) and spillway. Two hydrophones were installed at each main pier nose at two elevations throughout the dam (Figure 2).

All of the systems had similar functional and geometric designs, so only one spillbay (SB) was selected for model validation and error analysis. The locations of the acoustic transmitters for all test cases were obtained through a real-time kinematic GPS system (Trimble RTK 5700 with Zephyr Geodetic antenna, Trimble Navigation Ltd., Sunnyvale, CA, USA), which provided benchmark measurements for comparison with the 3D-tracked locations. The accuracy was assessed in terms of median and root mean square (RMS) values of the differences between GPS measurements and the source locations computed from 3D tracking codes:

Δ x i = | x i 3 D x i G P S | , i = 1 , N
Δ y i = | y i 3 D y i G P S | , i = 1 , N
Δ z i = | z i 3 D z i G P S | , i = 1 , N
Δ d i = Δ x i 2 + Δ y i 2 + Δ z i 2 , i = 1 , N
R M S x = 1 N i = 1 N Δ x i 2
R M S y = 1 N i = 1 N Δ y i 2
R M S z = 1 N i = 1 N Δ z i 2
R M S d = 1 N i = 1 N Δ d i 2
where N was the number of estimated positions and x, y, and z were the three components in the dam-face coordinate system. The dam-face coordinate system was defined as follows: the x-axis was perpendicular to the dam and looking straight into the forebay; the y-axis was along the dam face from the Oregon to the Washington side; and the z-axis was vertical, pointing upward.

The acoustic transmitters used in the validation tests had a ping rate of one pulse per second and a source level of 155 dB relative to 1 μPa at 1 m. Transmitters were attached at different water depths to a rope held steady by an anchor at the bottom. For the fixed-location tests, seven transmitters were suspended at 1, 2, 3, 5, 10, 15, and 20 m below the water surface and held at various locations from 5 m to 100 m upstream of the dam in the forebay (Figure 3). Each fixed location test lasted approximately 10 min, resulting in a typical sample size of 550 transmissions, given the 1-s pulse rate repetition. For the drogue drift, six transmitters were held at 1, 2, 3, 5, 10, and 15 m below the water surface. The GPS measurement point was about 1 m above the water surface. Because of the windy conditions and underwater currents, the rope holding the transmitters was not always steady, resulting in large uncertainties in transmitter locations in deep water. For this reason, only the transmitter held at 2 m below water surface was employed for the accuracy assessment, although all transmitters were included for tracking efficiency analysis.

2.4. Field-Scale Application at John Day Dam

This case study involved a total of 2,445 yearling Chinook salmon (YC) and 2,448 steelhead (STH) in Spring and in 2,483 subyearling Chinook salmon (SYC) in Summer passing through John Day Dam during 2008. Median lengths of tagged fish for these downstream migrating YC, STH, and SYC were 158 mm, 217 mm, and 117 mm, respectively. All fish were surgically implanted [36] with JSATS acoustic transmitters and passive integrated transponder (PIT) tags [37]. The size of the JSATS acoustic transmitters differed from spring to summer due to technological advances in transmitter design. In Spring, the transmitter mean weight was 0.485 g in air and 0.324 g in water, and transmitters were nominally 12.46 mm long, 5.30 mm wide, and 3.70 mm high. In Summer, the tag mean weight was 0.425 g in air and 0.290 g in water. Summer tags averaged 12.04 mm long, 5.27 mm wide, and 3.74 mm high. The acoustic transmitters used in this study had a ping rate of one pulse every 3 s to provide an expected transmitter life of at least 23 days.

Tagged YC and STH were released daily over a 29-day period in Spring (May 1 through May 29) near Arlington, OR, USA at rkm 390 (42 km upstream of John Day Dam, at 0,600, 1,200, and 1,800 hours). Similarly, acoustic-tagged SYC were released in summer over a 29-day period (June 15 through July 13) in three release groups at Arlington, OR, USA (at 0,600, 1,200, and 2,100 hours).

To receive signals from tagged fish, we deployed shallow and deep JSATS cabled hydrophones on the upstream face of John Day Dam with a total 21 systems and 84 hydrophones (dam-face array). We also deployed and maintained autonomous node arrays [38] at river cross sections, including 2 km upstream of John Day Dam (forebay array) and 9.4 km downstream of the dam (tailwater egress array). The forebay array was used to create a virtual release for fish as they enter the forebay 2 km upstream of the dam. The dam-face array was used to create a virtual release for fish known to have passed John Day Dam and to estimate route of passage at the dam using 3D tracking and last-detection data. The time of last detection by the dam-face array minus the time of first detection on the forebay array provided an estimate of forebay residence time. The time of first detection by the John Day Dam tailwater egress array minus the time of last detection on the dam-face array provided an estimate of relative egress time. The PIT-tag detection system was used to provide the percentage of fish passing the PH that were guided into the juvenile bypass facilities at John Day Dam.

Fish passage and behavior at the dam relative to the TSWs and two spill treatments (30% versus 40% spill out of total water discharge through the dam) were investigated using detections at the dam face coupled with forebay hydrophone detections and acoustic tracking. Fish detections were classified into “arrival blocks” based on forebay array data and “passage blocks” based on dam-face array data. The blocks corresponded to areas of the dam, moving from south to north, as indicated in Figure 2: PH turbine units 1–8, units 9–16, skeleton bays 17–20, SBs 17–20, TSW bays 15–16, and SBs 1–14. Skeleton bays were included in arrival blocks but not in passage blocks because fish could not pass there.

3. Results and Discussion

3.1. Validation Results

Tracking efficiency was evaluated as the number of successful 3D-tracked locations divided by the number of transmissions. All transmitters had high tracking efficiencies at distances of 5 m to 100 m from the dam face (Table 1). The transmitter attached to the rope at 20 m below the surface broke off before the 5-m location test. Occasionally, there were low tracking efficiencies at a few locations; for example, Transmitter 4 had an efficiency of 54.9% at 5 m and Transmitter 3 had an efficiency of 66.8% at 100 m. Tag 1 had lower efficiencies likely because of the multipath from the surface. These infrequent dips in tracking efficiency were likely due to the fact that we could not control the directivity of the transmitters during the tests.

Only the results of Transmitter 2 were selected for accuracy assessment. The median errors of the x-component (the distance to the dam face) ranged from 0.06 to 0.55 m at distances up to 75 m and ranged from 0.52 to 1.18 m at 100 m distance (Table 2).

The RMS errors fell between 0.1 and 0.98 m for distances up to 75 m and between 1.31 and 2.16 at 100 m distance. Figure 4 contains interpolation of the Transmitter 2 results. The y-component, used for the route assignment, had the highest accuracy among the three components. The median errors at SB 9 ranged from 0.02 to 0.22 m, and RMS errors ranged from 0.07 to 0.56 m at distances up to 100 m. When the distance was less than 50 m, the median errors and RMS errors were within 0.07 and 0.16 m, respectively. The z-component was in the vertical plane. At SB 9, the median errors of z-component ranged from 0.31 to 0.87 m, and the RMS errors ranged from 0.33 to 2.25 m for all distances. For absolute distances, the median errors were within 1 m for all distances except at the 100-m distance in the south and middle section (1.64 m and 1.67 m, respectively). RMS errors of absolute distances ranged from 0.37 to 3.17 m.

For the drogue drift test, the overall tracking efficiency was 93.2% (Figure 5). The median errors in x, y, z, and total distance were 0.20 m, 0.22 m, 0.38 m, and 0.52 m, respectively. RMSx, RMSy, RMSz, and RMSd were 0.49 m, 0.27 m, 0.95 m, and 1.10 m, respectively.

Both the median and RMS errors were computed from 3D-tracked positions that were slightly smoothed by order 3 median filtering without removing outliers. If outliers were removed, or if additional smoothing such as Kalman filtering algorithms were applied, the RMS errors could be reduced significantly. In addition, windy conditions and underwater current probably caused inaccuracies between GPS measurements and true transmitter locations, which would result in an increase in RMS errors.

3.2. Case Study

Of the 7,376 tagged fish released upstream of John Day Dam, 7,118 (97%) were detected by the autonomous receivers in the forebay. Of these 7,118 tagged fish, 7,067 (99%) were detected by the cabled systems, with a median number of detections of 1,066 (Figure 6). Another 6,975 (98%) were 3D-tracked; the median number of tracking positions was 101 (Figure 7).

At least half of the tagged fish arriving upstream of the PH turbine units and skeleton bays moved north to ultimately pass at the spillway, including the TSWs. This pattern was strongest for STH and weakest for SYC. Tagged fish arriving upstream of the spillway, however, did not tend to move south toward the PH (Figure 8). Specifically, for YC arriving in the forebay, 45% and 16% approached the PH upstream of turbine units 1–16 and the skeleton bays, respectively, whereas 12% arrived at SBs 17–20, 5% at the TSWs, and 22% at SBs 1–14. Of the fish first arriving at the PH, nearly 60% moved north and passed at the spillway, mostly at SBs 17–20 and the TSWs, closer to the PH. Conversely, 2% of YC arriving at the spillway moved south and passed via the PH. The remaining 98% passed via the spillway or TSWs.

For acoustic-tagged STH arriving in the forebay, 52% and 12% approached the PH upstream of turbine units 1–16 and the skeleton bays, respectively. Arrivals at the spillway included about 9% at SBs 17–20, 4% at the TSWs, and 23% at SBs 1–14. Nearly 66% of the STH that arrived at the PH moved north and passed at the spillway, primarily at the TSWs. Similar to YC, the majority of STH first approaching the spillway typically passed at SBs 1–14 or the TSWs; few STH arriving at the spillway moved south and passed at the PH. Overall, a noticeable portion of STH moved toward the TSWs, regardless of arrival block. For SYC, about 60% of those detected in the forebay arrived upstream of the PH turbine units and the skeleton bays. About half of these fish moved north to ultimately pass at the spillway, mostly at SBs 17–20 and the TSWs. Of the 25% of total SYC arriving at units 9–16, more than one-half passed there or at units 1–8 and did not move north toward the spillway.

Vertical distribution data were based on 3D tracking of individual acoustic-tagged fish. As smolts moved from 75 m to within 10 m of the PH face, travel depths often decreased, but there was a sudden increase to more than 20 m at a distance of less than 5 m from the PH. Note that PH piers on which hydrophones were mounted do not extend more than about 1 m upstream of the PH face so that sounding fish within 5 m of the dam face can be tracked moving down toward intake openings. The turbine intake ceilings at John Day Dam are about 20 m deep. At the spillway, detection depths were less than 5 m, regardless of distance upstream from the face of the spillway.

There was no difference in diel vertical distributions for PH- or spillway-passed YC. For STH, vertical distribution was shallow for fish passed through the spillway; this pattern was especially evident at the TSW. The last-detection depths at the PH were much deeper. Most SYC in the forebay of the PH and skeleton bays traveled at depths between 5 and 11 m, while median depths of smolts within 5 m of the PH or skeleton bays were between 20 and 25 m. As with YC and STH, the last-detection depths for SYC were relatively shallow at the spillway. Notably, as SYC approached the TSW, they migrated upward in the water column, but this trend was not evident for their approach at non-TSW SBs.

4. Conclusions

Time-of-arrival information for valid detections on four hydrophones was used to solve for the 3D position of fish surgically implanted with JSATS acoustic transmitters. Validation tests demonstrated high accuracy of 3D tracking up to a 100-m distance at the John Day Dam spillway. The along-dam component used for assigning the route of fish passage had the highest accuracy; the median errors ranged from 0.02 to 0.22 m, and RMS errors ranged from 0.07 to 0.56 m at distances up to 100 m. For the case study at John Day Dam during 2008, the range for 3D tracking was more than 100 m upstream of the dam face, where hydrophones were deployed and detection and tracking probabilities were more than 98%. JSATS cabled systems have been successfully deployed on several major dams to acquire information for salmon protection and for development of more “fish-friendly” hydroelectric facilities.

Acknowledgments

The work described in this article was funded by the U.S. Army Corps of Engineers, Portland District. The study was conducted at Pacific Northwest National Laboratory (PNNL), operated in Richland, Washington, by Battelle for the U.S. Department of Energy. The authors thank Robert Wertheimer of the USACE and Derrek Faber, James Hughes, Mitchell Myjak, Geoff McMichael, Gene Ploskey of PNNL for their help with this study. Numerous staff from the Pacific States Marine Fisheries Commission and other PNNL staff from the Ecology Group, Hydrology Group, Marine Sciences Laboratory, and Instrument Development Laboratory worked hard to develop and prove this technology. Sonic Concepts Inc. provided innovative engineering, prototype development, and production of transmitters and receiving equipment. Advanced Telemetry Systems set a new standard for acoustic tag size and performance. Andrea Currie and Jayson Martinez of PNNL provided comments and technical help preparing the manuscript. The authors are also grateful to the four anonymous reviewers whose comments substantially improved the initial manuscript.

References

  1. Cada, GF. The Development of Advanced Hydroelectric Turbines to Improve Fish Passage Survival. Fisheries 2001, 26, 14–23. [Google Scholar]
  2. Odeh, M; Sommers, G. New Design Concepts for Fish Friendly Turbines. Int. J. Hydropower Dams 2000, 7, 64–71. [Google Scholar]
  3. Neitzel, DA; Dauble, DD; Cada, GF; Richmond, MC; Guensch, GR; Mueller, RP; Abernethy, CS; Amidan, BG. Survival Estimates for Juvenile Fish Subjected to a Laboratory-Generated Shear Environment. Trans. Am. Fish. Soc 2004, 133, 447–454. [Google Scholar]
  4. Deng, Z; Guensch, GR; McKinstry, CA; Mueller, RP; Dauble, DD; Richmond, MC. Evaluation of Fish-Injury Mechanisms During Exposure to Turbulent Shear Flow. Can. J. Fish. Aquat. Sci 2005, 62, 1513–1522. [Google Scholar]
  5. Deng, ZQ; Carlson, TJ; Ploskey, GR; Richmond, MC; Dauble, DD. Evaluation of Blade-Strike Models for Estimating the Biological Performance of Kaplan Turbines. Ecol Model 2007, 208, 165–176. [Google Scholar] [CrossRef]
  6. Deng, Z; Mueller, RP; Richmond, MC; Johnson, GE. Injury and Mortality of Juvenile Salmon Entrained in a Submerged Jet Entering Still Water. N. Am. J. Fish. Manage 2010, 30, 623–628. [Google Scholar]
  7. Nehlsen, W; Williams, JE; Lichatowich, JA. Pacific Salmon at the Crossroads: Stocks at Risk from California, Oregon, Idaho, and Washington. Fisheries 1991, 16, 4–21. [Google Scholar]
  8. Coutant, CC; Whitney, RR. Fish Behavior in Relation to Passage Through Hydropower Turbines: A Review. Trans. Am. Fish. Soc 2000, 129, 351–380. [Google Scholar]
  9. Deng, Z; Carlson, TJ; Duncan, JP; Richmond, MC; Dauble, DD. Use of an Autonomous Sensor to Evaluate the Biological Performance of the Advanced Turbine at Wanapum Dam. J Renew Sustain Energ 2010, 2, 053104:1–053104:11. [Google Scholar] [CrossRef]
  10. Deng, Z; Carlson, TJ; Dauble, DD; Ploskey, GR. Fish Passage Assessment of an Advanced Hydropower Turbine and Conventional Turbine Using Blade-Strike Modeling. Energies 2011, 4, 57–67. [Google Scholar]
  11. Parkinson, BW; Spilker, JJ, Jr; Axelrad, P; Enge, P. Global Positioning System: Theory and Applications; American Institute of Aeronautics and Astronautics: Reston, VA, USA, 1996; p. 793. [Google Scholar]
  12. Misra, P; Enge, P. Global Positioning System: Signals, Measurements, and Performance, 2nd ed; Ganga-Jamuna Press: Lincoln, MA, USA, 2001; p. 569. [Google Scholar]
  13. Watkins, WA; Schevill, WE. Sound Source Location by Arrival-Times on a Non-Rigid Three-Dimensional Hydrophone Array. Deep Sea Res. Part A 1972, 19, 691–706. [Google Scholar]
  14. Spiesberger, JL; Fristrup, KM. Passive Location of Calling Animals and Sensing of Their Acoustic Environment Using Acoustic Tomography. Am. Nat 1990, 135, 107–153. [Google Scholar]
  15. Wahlberg, M; Mohl, B; Madsen, PT. Estimating Source Position Accuracy of a Large-Aperture Hydrophone Array for Bioacoustics. J. Acoust. Soc. Am 2001, 109, 397–406. [Google Scholar]
  16. Au, WWL; Herzing, DL. Echolocation of Wild Atlantic Spotted dolphin (Stenella frontalis). J. Acoust. Soc. Am 2003, 113, 598–604. [Google Scholar]
  17. Drake, S; Dogancay, K. Geolocation by Time Difference of Arrival Using Hyperbolic Asymptotes. Proceedings of 2004 IEEE International Conference on Acoustics, Speech, and Signal Processing, Montreal, QC, Canada, 17–21 May 2004.
  18. Friedlander, B. A Passive Localization Algorithm and Its Accuracy Analysis. IEEE J. Ocean. Eng 1987, 12, 234–245. [Google Scholar]
  19. Huang, Y; Benesty, J; Elko, GW; Mersereau, RM. Realtime Passive Source Localization: A Practical Linear-Correction Least-Squares Approach. IEEE Trans. Speech Audio Process 2001, 9, 943–956. [Google Scholar]
  20. Foy, WH. Position-Location Solutions by Taylor-Series Estimation. 1976, 187–194. [Google Scholar]
  21. Tonieri, DJ. Statistical Theory of Passive Location Systems. 1984, 183–198. [Google Scholar]
  22. Fang, BT. Simple Solutions for Hyperbolic and Related Position Fixes. IEEE Trans. Aerosp. Electron. Syst 1990, 26, 748–753. [Google Scholar]
  23. Juell, J-E; Westerberg, H. An Ultrasonic Telemetric System for Automatic Positioning of Individual Fish Used to Track Atlantic Salmon (Salmo salar L.) in a Sea Cage. Aquacult. Eng 1993, 12, 1–18. [Google Scholar]
  24. Axelrad, P; Brown, RG. GPS Navigation Algorithms. In Global Positioning System: Theory and Applications; Parkinson, BW, Spilker, JJ, Jr, Axelrad, P, Enge, P, Eds.; American Institute of Aeronautics and Astronautics, Inc: Reston, VA, USA, 1996; Volume 1, pp. 409–434. [Google Scholar]
  25. Chan, YT; Ho, KC. A Simple and Efficient Estimator for Hyperbolic Location. IEEE Trans. Signal Process 1994, 42, 1905–1915. [Google Scholar]
  26. Yarlagadda, R; Ali, I; Al-Dhahir, N; Hershey, J. Geometric Dilution of Precision (GDOP): Bounds and Properties; Technical Report 97CRD119; General Electric Research and Development Center: Niskayuna, NY, USA, 1997. [Google Scholar]
  27. Caffery, JJ, Jr. A New Approach to the Geometry of TOA Location. Proceedings of Vehicular Technology Conference Fall 2000—Bringing Global Mobility to the Network Age, Boston, MA, USA, 24–28 September 2000; pp. 1943–1949.
  28. Bucher, R; Misra, D. A Synthesizable Low Power VHDL Model of the Exact Solution of a Three-Dimensional Hyperbolic Positioning System. VLSI Des 2002, 15, 507–510. [Google Scholar]
  29. Cheung, KW; So, HC; Ma, W-K; Chan, YT. Least Squares Algorithms for Time-of-Arrival-Based Mobile Location. IEEE Trans. Signal Process 2004, 52, 1121–1128. [Google Scholar]
  30. Chan, YT; Hang, HYC; Ching, P-C. Exact and Approximate Maximum Likelihood Localization Algorithms. IEEE Trans. Vehic. Tech 2006, 55, 10–16. [Google Scholar]
  31. Weiland, MA; Deng, Z; Seim, TA; LaMarche, BL; Choi, EY; Fu, T; Carlson, TJ; Thronas, AI; Eppard, BM. A Cabled Acoustic Telemetry System for Detecting and Tracking Juvenile Salmon. Part 1: Engineering Design and Instrumentation. Sensors 2011, 11, 5645–5660. [Google Scholar]
  32. Deng, Z; Weiland, M; Carlson, T; Eppard, MB. Design and Instrumentation of a Measurement and Calibration System for an Acoustic Telemetry System. Sensors 2010, 10, 3090–3099. [Google Scholar]
  33. Ehrenberg, JE; Steig, TW. A Method for Estimating the Position Accuracy of Acoustic Fish Tags. ICES J. Mar. Sci 2002, 59, 140–149. [Google Scholar]
  34. Marczak, W. Water as a Standard in the Measurements of Speed of Sound in Liquids. J. Acoust. Soc. Am 1997, 102, 2776–2779. [Google Scholar]
  35. Lim, JS. Two-Dimensional Signal and Image Processing; Prentice Hall: Englewood Cliffs, NJ, USA, 1990; pp. 469–476. [Google Scholar]
  36. Deters, KA; Brown, RS; Carter, KM; Boyd, JW; Eppard, MB; Seaburg, AG. Performance Assessment of Suture Type, Water Temperature, and Surgeon Skill in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters. Trans. Am. Fish. Soc 2010, 139, 888–899. [Google Scholar]
  37. Skalski, JR; Smith, SG; Iwamoto, RN; Williams, JG; Hoffman, A. Use of Passive Integrated Transponder Tags to Estimate Survival of Migrant Juvenile Salmonids in the Snake and Columbia Rivers. Can. J. Fish. Aquat. Sci 1998, 55, 1484–1493. [Google Scholar]
  38. McMichael, GA; Eppard, MB; Carlson, TJ; Carter, JA; Ebberts, BD; Brown, RS; Weiland, MA; Ploskey, GR; Harnish, RA; Deng, ZD. The Juvenile Salmon Acoustic Telemetry System: A New Tool. Fisheries 2010, 35, 9–22. [Google Scholar]
Figure 1. Location of John Day Dam on the Columbia River at rkm 348.
Figure 1. Location of John Day Dam on the Columbia River at rkm 348.
Sensors 11 05661f1 1024
Figure 2. Location of JSATS hydrophones on the dam face of John Day Dam. The yellow dots represent hydrophone locations.
Figure 2. Location of JSATS hydrophones on the dam face of John Day Dam. The yellow dots represent hydrophone locations.
Sensors 11 05661f2 1024
Figure 3. Error analysis test locations at John Day Dam spillway.
Figure 3. Error analysis test locations at John Day Dam spillway.
Sensors 11 05661f3 1024
Figure 4. Contour plots of RMS errors of the transmitter at 2 m below the water surface, John Day Dam spillway: (a) x; (b) y, (c) z.
Figure 4. Contour plots of RMS errors of the transmitter at 2 m below the water surface, John Day Dam spillway: (a) x; (b) y, (c) z.
Sensors 11 05661f4 1024
Figure 5. Comparison of GPS measurements and 3D-tracked positions at John Day Dam spillway.
Figure 5. Comparison of GPS measurements and 3D-tracked positions at John Day Dam spillway.
Sensors 11 05661f5 1024
Figure 6. Number of detections by cabled systems at John Day Dam, 2008.
Figure 6. Number of detections by cabled systems at John Day Dam, 2008.
Sensors 11 05661f6 1024
Figure 7. Examples of 3D tracks at John Day Dam, 2008. Note that water surface is not plotted.
Figure 7. Examples of 3D tracks at John Day Dam, 2008. Note that water surface is not plotted.
Sensors 11 05661f7 1024
Figure 8. Distribution of passage sections and first detection of yearling Chinook salmon at John Day Dam, 2008.
Figure 8. Distribution of passage sections and first detection of yearling Chinook salmon at John Day Dam, 2008.
Sensors 11 05661f8 1024
Table 1. Tracking efficiency of JSATS cabled system at fixed locations.
Table 1. Tracking efficiency of JSATS cabled system at fixed locations.
Transmitter indexDepth from surface (m)Tracking efficiency (%) at
5 m15 m30 m50 m75 m100 m
1187.089.088.686.869.349.9
2293.995.588.896.787.480.3
3392.189.190.493.086.766.8
4554.999.699.198.994.886.8
51098.899.399.698.898.296.5
61584.699.598.699.198.397.7
720N/A89.198.798.599.195.8
Table 2. Median and RMS errors of the transmitter at 2 m below the water surface at SB 9, John Day Dam spillway.
Table 2. Median and RMS errors of the transmitter at 2 m below the water surface at SB 9, John Day Dam spillway.
LocationDistance (m)Median (Δxi)Median (Δyi)Median (Δzi)Median (Δdi)RMSxRMSyRMSzRMSd
North50.060.060.390.400.100.080.390.41
150.060.070.350.370.120.110.330.37
500.220.070.570.640.380.122.132.16
750.400.110.460.680.660.161.351.51
1000.520.130.420.781.310.250.991.66

Middle50.340.050.310.690.970.080.931.35
150.060.050.410.440.370.092.112.15
300.210.020.870.940.370.161.821.86
500.340.110.530.710.980.172.192.41
750.510.110.580.990.860.161.802.00
1001.180.170.591.641.920.272.172.90

South50.070.060.400.420.130.080.430.45
150.060.040.400.400.320.070.400.52
300.110.050.530.560.210.090.540.59
500.180.040.560.600.350.110.660.75
750.550.180.570.950.790.241.781.96
1001.130.220.591.672.160.562.253.17

Share and Cite

MDPI and ACS Style

Deng, Z.D.; Weiland, M.A.; Fu, T.; Seim, T.A.; LaMarche, B.L.; Choi, E.Y.; Carlson, T.J.; Eppard, M.B. A Cabled Acoustic Telemetry System for Detecting and Tracking Juvenile Salmon: Part 2. Three-Dimensional Tracking and Passage Outcomes. Sensors 2011, 11, 5661-5676. https://doi.org/10.3390/s110605661

AMA Style

Deng ZD, Weiland MA, Fu T, Seim TA, LaMarche BL, Choi EY, Carlson TJ, Eppard MB. A Cabled Acoustic Telemetry System for Detecting and Tracking Juvenile Salmon: Part 2. Three-Dimensional Tracking and Passage Outcomes. Sensors. 2011; 11(6):5661-5676. https://doi.org/10.3390/s110605661

Chicago/Turabian Style

Deng, Z. Daniel, Mark A. Weiland, Tao Fu, Tom A. Seim, Brian L. LaMarche, Eric Y. Choi, Thomas J. Carlson, and M. Brad Eppard. 2011. "A Cabled Acoustic Telemetry System for Detecting and Tracking Juvenile Salmon: Part 2. Three-Dimensional Tracking and Passage Outcomes" Sensors 11, no. 6: 5661-5676. https://doi.org/10.3390/s110605661

Article Metrics

Back to TopTop