Next Article in Journal
Hardware Accelerated Compression of LIDAR Data Using FPGA Devices
Previous Article in Journal
Analysis of the Accuracy and Robustness of the Leap Motion Controller
Article Menu

Export Article

Open AccessArticle
Sensors 2013, 13(5), 6394-6404; doi:10.3390/s130506394

Performance of a Cyanobacteria Whole Cell-Based Fluorescence Biosensor for Heavy Metal and Pesticide Detection

Faculty of Science, Technology, Engineering and Mathematics, INTI International University, Nilai, Negeri Sembilan 71800, Malaysia
Faculty of Science and Technology/South-East Asia Disaster Prevention Research Institute, University Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia
Faculty of Science and Technology, University Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia
Author to whom correspondence should be addressed.
Received: 6 March 2013 / Revised: 10 April 2013 / Accepted: 16 April 2013 / Published: 14 May 2013
(This article belongs to the Section Biosensors)
View Full-Text   |   Download PDF [453 KB, uploaded 21 June 2014]   |  


Whole cell biosensors always face the challenge of low stability of biological components and short storage life. This paper reports the effects of poly(2-hydroxyethyl methacrylate) (pHEMA) immobilization on a whole cell fluorescence biosensor for the detection of heavy metals (Cu, Pb, Cd), and pesticides (dichlorophenoxyacetic acid (2,4-D), and chlorpyrifos). The biosensor was produced by entrapping the cyanobacterium Anabaena torulosa on a cellulose membrane, followed by applying a layer of pHEMA, and attaching it to a well. The well was then fixed to an optical probe which was connected to a fluorescence spectrophotometer and an electronic reader. The optimization of the biosensor using several factors such as amount of HEMA and drying temperature were undertaken. The detection limits of biosensor without pHEMA for Cu, Cd, Pb, 2,4-D and chlorpyrifos were 1.195, 0.027, 0.0100, 0.025 and 0.025 µg/L respectively. The presence of pHEMA increased the limits of detection to 1.410, 0.250, 0.500, 0.235 and 0.117 µg/L respectively. pHEMA is known to enhance the reproducibility of the biosensor with average relative standard deviation (RSD) of ±1.76% for all the pollutants tested, 48% better than the biosensor without pHEMA (RSD = ±3.73%). In storability test with Cu 5 µg/L, the biosensor with pHEMA performed 11.5% better than the test without pHEMA on day-10 and 5.2% better on day-25. pHEMA is therefore a good candidate to be used in whole cell biosensors as it increases reproducibility and enhances biosensor storability.
Keywords: whole cell biosensor; pHEMA; heavy metals; pesticides whole cell biosensor; pHEMA; heavy metals; pesticides
This is an open access article distributed under the Creative Commons Attribution License (CC BY 3.0).

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

Wong, L.S.; Lee, Y.H.; Surif, S. Performance of a Cyanobacteria Whole Cell-Based Fluorescence Biosensor for Heavy Metal and Pesticide Detection. Sensors 2013, 13, 6394-6404.

Show more citation formats Show less citations formats

Related Articles

Article Metrics

Article Access Statistics



[Return to top]
Sensors EISSN 1424-8220 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top