Approximate Analysis of Multi-State Weighted k-Out-of-n Systems Applied to Transmission Lines

1
School of Computer Science and Engineering, Northwestern Polytechnical University, Xi’an 710072, China
2
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada
*
Authors to whom correspondence should be addressed.
Energies 2017, 10(11), 1740; https://doi.org/10.3390/en10111740
Submission received: 11 September 2017 / Revised: 23 October 2017 / Accepted: 24 October 2017 / Published: 30 October 2017
(This article belongs to the Special Issue 2017 Prognostics and System Health Management Conference)

Abstract

:
Multi-state weighted k-out-of-n systems are widely applied in various scenarios, such as multiple line (power/oil transmission line) transmission systems where the capability of fault tolerance is desirable. However, the complex operating environment and the dynamic features of load demands influence the evaluation of system reliability. In this paper, a stochastic multiple-valued (SMV) approach is proposed to efficiently predict the reliability of two models of systems with non-repairable components and dynamically repairable components. The weights/performances and reliabilities of multi-state components (MSCs) are represented by stochastic sequences consisting of a fixed number of multi-state values with the positions being randomly permutated. Using stochastic sequences with L multiple values, linear computational complexities with parameters n and L are required by the SMV approach to compute the reliability of different multi-state k-out-of-n systems at a reasonable accuracy, compared to the complexities of universal generating functions (UGF) and fuzzy universal generating functions (FUGF) that increase exponentially with the value of n. The analysis of two benchmarks shows that the proposed SMV approach is more efficient than the analysis using UGF or FUGF.

1. Introduction

The k-out-of-n system is widely used to model various industrial systems that require the adoption of redundancy for the purpose of fault tolerance, such as multiple lines transmission systems and production systems consuming multiple resources [1]. A binary-stated k-out-of-n: G system is anticipated to be reliable unless the number of working components is no less than a pre-specified threshold k [2], and a binary-stated k-out-of-n: F system is inaccessible when the number of failed components is no less than k [3]. However, some engineering systems such as power/oil lines transmission systems perform the intended tasks at multiple performance levels, which indicates the system’s capability (electric power, oil, etc.) from perfectly operational to completely out-of-order [4]. Another example is of a power generator in a power station that can work at full capacity; however, some types of failure cause the generator to completely fail and other failures lead to the generator working at a reduced capacity. The abilities of a power generating system consisting of several power generators to meet different power load demands can be regarded as different system states [5]. Hence, the binary-valued assumption is incapable of accurately reflecting the behaviors of these systems. Instead, these systems can be described as multi-state systems (MSS) [5]. A multi-state k-out-of-n: G system and a multi-state k-out-of-n: F system model were investigated in References [6,7].
The performance of a practical system is not only dependent on system operation but is also affected by the total contribution of all the components. The contribution of a component can be quantified and the total contribution of all components is supposed to be above a pre-specified performance level [8]. For example, consider a power station with three components, and each component is a generator. Each component has maybe three different states: 0, 1, 2; and the distribution probability may be different in each state. The power outputs of a component are 0 megawatts (MW), 10 MW, and 100 MW, corresponding the states 0, 1, 2. The total power output of the system is the weighted sum of each component. When the total output is greater than 100 MW, the system is in state 2; when the output is greater than 50 MW, the system is in state 1; otherwise, it is in state 0. The reliability of a system is defined by considering its structure and the weight of each component [9]. Then, the proposed models for binary and multi-state k-out-of-n systems are generalized into binary and multi-state weighted models [10,11,12]. For a weighted k-out-of-n system, the weight of the component i in state j is assigned to be w i j . The system is supposed to be correctly working only if the total weight of the components is no less than the pre-determined value of K.
To perform the reliability analysis of a k-out-of-n system, the method of universal generating function (UGF) is adopted. This concept was introduced in Reference [13] and it was first utilized to predict the reliability of a power system in Reference [14]. In previous research [4,15,16,17,18], the UGF technique was used to determine the reliability of several multi-state systems, which are composed of series, parallel, series-parallel, and bridge structures. The required computational complexity analysis of the UGF technique to evaluate the reliability of a multi-state weighted k-out-of-n system is performed in Reference [11]. The number of system states increases dramatically with the system scale (the adoption of more components) [19], so the UGF method incurs a large computational complexity for systems consisting of many components or multi-state components. In order to reduce the computational complexity, a fuzzy universal generating function (FUGF) method is presented in References [20,21]. It combines the fuzzy set theory [22,23], UGF, and a clustering technique [24] to obtain the reliability of a multi-state weighted k-out-of-n system. However, the clustering technique in FUGF is likely to reduce the prediction accuracy of the results considerably and usually too much time is consumed.
The UGF and FUGF methods can be used to perform exact and approximate performance assessments of a multi-state k-out-of-n system, respectively. However, the above methods are mainly focused on the steady state study of a multi-state k-out-of-n system with the assumption of non-repairable property for the component. In practice, the corresponding state probability may gradually change with time because of the aging process [25]. When considering repairable operations, the performance of a component can not only transmit to a lower level, but also return to a higher level unless the component is completely failed. A dynamic general k-out-of-n system with repairable components is investigated in Reference [26], and the discrete time Markov chain and UGF are combined to predict the system reliability. However, aiming to perform the analysis of a complex system, a large complexity is required according to the state transition matrix (STM).
In this paper, a stochastic multiple-valued (SMV) approach is presented that aims to predict the reliability of different multi-state k-out-of-n systems. The weights and reliabilities of components are encoded into randomly permuted multiple-valued sequences. The corresponding proposed stochastic architectures are composed of stochastic multi-valued logic gates. By propagating the multiple-valued sequences through the above stochastic architecture, an output sequence can be inherently obtained. Then, the corresponding reliability is predicted by analyzing the output sequence of the proposed model.
The remainder of the paper is organized as follows: In Section 2, some fundamentals related to UGF, FUGF, and the two models of multi-state weighted k-out-of-n systems are reviewed. In Section 3, corresponding stochastic models are presented for a multi-state k-out-of-n system with non-repairable components as well as for a dynamic system with repairable components. Then, the proposed stochastic multi-valued models are validated by a theoretical proof. Section 4 gives some case studies and a comparison of simulation results with different methods. Finally, Section 5 concludes the paper, as well as provides some future work.

2. Multi-State k-Out-of-n System and UGF, FUGF Methods

In this section, two types of multi-state weighted k-out-of-n systems [11], using universal generating function (UGF) and fuzzy universal generating function (FUGF), are presented.

2.1. Multi-State Weighted k-Out-of-n System

The definition of model I of multi-state weighted k-out-of-n systems is given as follows [11]:
Definition 1.
In a system with n components, each component can be in M + 1 states: 0, 1, 2, …, M. Component i (1 ≤ i ≤ n) in state j carries a weight of w i j with a probability of p i j (0 ≤ j ≤ M). The system is in state j or a higher state if the total weights of all the components is greater than or equal to K , a pre-defined value. Then, we have P r { ϕ j } = P r { W K } , where ϕ is the structure function of a system and W describes the total weight of all components.
Because in some systems the components whose states are below j do not make any contribution for the system to be in state j or a higher state, then the model II is described below.
Definition 2.
The system is in state j or a higher state if the sum of the weights of the components in state j or a higher state is greater than or equal to K . We can have P r { ϕ j } = P r { W K } , where ϕ is the structure function of a system and W denotes the total weight of the components in state j or a higher state.

2.2. UGF and FUGF

For UGF, the output performance distribution (OPD) is described by a polynomial function of US(z). The function relates to the weight wj, and the corresponding probability (reliability) Pj of the system in the state j is given by:
U s ( z ) = j = 0 M P j · z w j ,
where M is the highest state of the system. The probability distribution (PD) of component i can be obtained by:
u i ( z ) =   j = 0 M p i j · z α ( w i j l ) , ( w i j l ) = { w i j , w i j l 0   , w i j < l .
where l is zero and a pre-defined non-zero value in model I and model II of the multi-state weighted system, respectively. p i j represents the corresponding probability if component i is supposed to be in state j (0 ≤ jM), while w i j denotes the corresponding weight of the above scenario, and w i j 0 .
In order to obtain the PD of a multi-state weighted k-out-of-n system with an arbitrary structure function ϕ , a composition operator Ω ϕ is represented by the UGF of n system components as follows [11]:
U s ( z ) = Ω ϕ { u 1 ( z ) ,   , u n ( z ) } =   Ω ϕ { j = 0 M p 1 j · z α ( w 1 j l ) ,   ,   j = 0 M p n j · z α ( w n j l ) } , = j = 0 M j = 0 M p 1 j p n j · z α ( w 1 j l ) + + α ( w n j l ) ,
where U s ( z ) represents the OPD of the system.
Then, we can obtain the reliability of a system for any required weight ( K ) using the operator δ A in Equation (4), when the UGF of a multi-state weight k-out-of-n system is obtained:
R s ( K ) = δ A ( U s ( z ) , K ) = δ A ( j = 0 M P j · z w j   , K ) = j = 0 M P j · α ( w j K ) ,
where α ( x ) = { 1   , x 0 . 0   , x < 0 .
In some systems, the dimension of the weight vector/state vector of subsystems is too large. To reduce the computational overhead, a fuzzy universal generating function (FUGF) is proposed [19,21]. The weight vector and state vector of the subsystem are divided into some clusters [24], and these clusters are represented by the fuzzy values. Hence, a multi-state weight of k-out-of-n system with n components is transformed into a fuzzy multi-state weight of k-out-of-n system with n * subsystems, and each subsystem i * consists of n i * components. The PD of subsystem i * can be determined by adopting the UGF method [21].

3. The Stochastic Multiple-Valued Models

3.1. Stochastic Multiple-Valued Logic

For stochastic computation, signal probability is indicated by a random binary bit stream [27]. In the binary steam, a proportional number of bits is set to be 1, aiming to denote the signal probability. Stochastic computation can also perform a probabilistic analysis of multiple-valued signals by using logic gates. For certain signals with a discretization level of m , the probability vector is usually described as P = [pm−1p0], with h = 0 m 1 p h = 1 . In Figure 1, a probability vector of a ternary-valued signal is indicated by a multi-valued sequence [28].
A multiple-valued smaller (MVS) operator and a multi-valued equal or larger (MVEL) operator perform the functions:
M V S ( A < a ) = { A , A < a 0   , A a .
M V E L ( A a ) = { A , A a 0   , A < a .
The ternary-valued gates such as an inverter, an MVS operator, an MVEL operator, and a 4-to-1 multiplexer are introduced in Figure 2.
As discussed in Reference [27], the result of stochastic computational analysis is usually a probabilistic value because of the inevitable fluctuations of stochastic computation. For a Bernoulli sequence Sa, which is adopted to encode probability Pa, the final result P _   a is usually different from Pa due to random fluctuations. If the length of Sa is L, the fluctuation error ef is assumed to be the difference between Pa and P _   a . It can be approximated as [29]:
e f = P a ( 1 P _   a ) L .
Equation (7) indicates that the fluctuation error can be reduced by adopting a longer sequence length. It has been shown that stochastic fluctuation can be significantly attenuated if the initial inputs are non-Bernoulli sequences; here, the corresponding sequence is composed of fixed numbers of 1s and 0s while the positions are randomly permutated [30]. Furthermore, the application of non-Bernoulli sequences is capable of reducing the result inaccuracy. Hence, the stochastic multi-valued sequence in Reference [28] is adopted to deal with multi-valued scenarios and utilized as the input of stochastic multi-valued models proposed in this paper.

3.2. SMV Models for a Multi-State k-Out-of-n System with Non-Repairable Components

For the stochastic multi-valued model, the weights of components are encoded in the multi-values stochastic sequences. As shown in Figure 3, the weights and reliabilities of component i at different states are simultaneously encoded into stochastic multi-value sequences.
The weights and PD of multi-state weighted k-out-of-n systems consisting of non-repairable components can be obtained by the output sequence of an add operation, as shown in Figure 4.
In Figure 4, w i j and p i j are the weight and probability of component Ci in state j, the sequence Si encodes the weights and reliabilities of Ci in all states, and the total number of values in sequence Si is L, i ∊ [1, n], j ∊ [0, M]. The sequence Si is the output of an MVEL gate. As defined in Equation (2), the value of l can be zero or a pre-defined non-zero value—it is determined by model I or model II of the multi-state weighted k-out-of-n system. The sequence Sout represents the sum of sequence Si, and the weights and the PD of the system can be obtained from Sout. K is the required weight of the system. R S K is a proportional number of non-zero values in Sout; it denotes the reliability of the system for the required weight K .

3.3. SMV Models for a Multi-State k-Out-of-n System with Repairable Components

For some systems, the corresponding state of a component may gradually change with time due to aging. Hence, a multi-state weighted k-out-of-n system that considers the time factor was proposed in Reference [26] with the incorporation of dynamic behavior. A state of each component may be changed to a lower state. In addition, the component can return to a higher state when the component is repairable. Assuming that a time period T is divided into a number of time intervals ΔT, the representation of the states for a repairable component i within the given period T are presented in Figure 5.
Let component i be in state M (which is being regarded as perfectly operational) at the start of the mission time. P M j i denotes the probability transforming from the state M to another state j of component i. Hence, component i has a state transition matrix (STM) as:
S T M i = [ P 00 i P 0 M i P M 0 i P M M i ]   S 0 i S M i .
In Equation (8), i , j = 0 M P m j i = 1 , m ∊ [0, M]. Let P j i ( t ) and P m i ( t 1 ) indicate the probabilities of component i in state j at time t and in state m at time t − 1, respectively. At time t − 1, any state of component i can be changed to state j, and the transition probability is P m j i . Based on S T M i and Figure 5, P j i ( t ) is given by:
P j i ( t ) = m = 0 M P m i ( t 1 ) · P m j i ,   i   [ 1 ,   n ] ,   t     [ 0 ,   T T ] ,
where P M i ( 0 ) = 1 , P h i ( 0 ) = 0 , h ∊ [0, M − 1].
The stochastic multi-valued architecture for a dynamic multi-state weighted k-out-of-n system with repairable components is presented as in Figure 6. Here, the transition probability Pimj (m, j ∊ [0, M]; i ∊ [1, n]) and corresponding states are encoded in sequence Sim with length L (as shown in Equation (8)). A proportional number of 0s in sequence Sim(t − 1) denotes the corresponding probability of component i being in state m at time point t − 1 (i.e., Pim(t − 1)). In sequence Sim(t − 1) with length L, Pim(t − 1)·L digits are valid, L × (1 − Pim(t − 1)) digits are filled with an invalid number V (i.e., elements in sequence Sim(t − 1) are only ‘0’ and V), V is used to compensate sequence Sim(t − 1), and ‘0’ ensures that the maximum state of component i is still M at time point t. If sequences Sim and Sim(t − 1) are the inputs of an add operation, the proportional number of valid values in the output sequence indicates the probability of component i being in the state of m at time point t. Sequence Si(t) denotes the PD of components i in different states at time t. The states in the sequence Si(t) are replaced by the corresponding weights to be sequence S i ( t ) by the block STW (state to weight). The sequences S i ( t ) are the inputs of the model for a multi-state weighted k-out-of-n system with non-repairable components (referred to as MMWN) in Figure 4. RKS (t) denotes the corresponding system reliability meeting the requirement of a pre-specified value of K at time t.

3.4. Validation of the Stochastic Multi-Valued Models

To validate the proposed stochastic multi-valued model for a multi-state weighted k-out-of-n system with non-repairable components, a theoretical proof is first presented.
Theorem 1.
The product of polynomials u 1 ( z ) = ( j = 0 M P j · z w j ) and u 2 ( z ) = ( i = 0 M P i · z w i ) , where P j and w j are encoded in a stochastic multi-valued sequence s 1 , and P i and w i are encoded in a stochastic multi-valued sequence s 2 as in Figure 3, is encoded in the sum of s 1 and s 2 .
Proof of Theorem 1.
Assuming n = 2 in Equation (3), the probability mass functions (PMFs) of two components ( u 1 and u 2 ) indicate the reliability and weight of each state for a component. As per Equation (2), u1 and u2 can be represented by polynomials u 1 ( z ) and u 2 ( z ) . The reliabilities and the weights of all states for component i are encoded in the stochastic multi-valued sequence s i , i ∊ [1, n].
As shown in Reference [29], the product of polynomials u 1 ( z ) and u 2 ( z ) can be expressed as a convolution of u 1 and u 2 . Equation (3) performs a polynomial multiplication. Hence, Equation (3) can be described by:
U s ( z )   = Ω ϕ { u 1 ( z ) ,   u 2 ( z ) }   =   u 1 u 2 ,  
where u 1 u 2 denotes the convolution of u 1 and u 2 .
The PD of the sum of two or more independent random variables is the convolution of their individual distributions [31], so we have:
u 1 u 2 = u t e m p ,
where u t e m p is the PMF of a temporary variable; the weights of the variable are obtained by summing the two components’ weights.
In the stochastic multi-valued models, the probabilities and weights of the two components are encoded in the stochastic multi-value sequences s 1 and s 2 , and the number of the multi-values in these sequences is L. In other words, sequences s 1 and s 2 encode u 1 and u 2 , respectively. u t e m p is then encoded by summing the sequence s 1 and s 2 . This completes the proof.
Hence, the proposed model for a multi-state weighted k-out-of-n system with non-repairable components shown in Figure 4 is validated.
The validation of the proposed stochastic multi-value model for a dynamic multi-state weighted k-out-of-n system with repairable components is presented as follows.
As defined in Equation (1), the transition probabilities P m j i of component i and its states are given by:
u m i = j = 0 M   P m j i   · z j ,
where M + 1 is the number of states. Let u m i ( t 1 ) denote the probability of component i at time t − 1 (i.e., P m i ( t 1 ) ); then, we have:
u m i ( t 1 ) =   P m i ( t 1 ) · z 0 +   ( 1     P m i ( t 1 ) )   · z v ,
where v is an invalid number. Let U m i ( t ) denote the performance distribution of component i in state m at time t; thus, we obtain:
U m i ( t )   =     Ω ϕ { u m i ,   u m i ( t 1 ) } = j = 0 M P m j i P m i ( t 1 ) · z j + 0 + j = 0 M P m j i ( 1 P m i ( t 1 ) ) · z j + v = j = 0 M P m j i P m i ( t 1 ) · z j .
assuming that the transition probabilities P m j i and the states of component i are encoded in a stochastic multi-value sequence s m i . In the sequence S m i ( t 1 ) , a probability of component i at time t − 1 in state m (i.e., P m i ( t 1 ) ) is encoded as a proportional number of 0s, and the other values in the sequence are invalid numbers v (m, j ∊ [0, M]; i ∊ [1, n]).
As per Theorem 1, Equation (14) can be obtained by summing the stochastic multi-value sequences S m i and S m i ( t 1 ) , and Equation (14) is equivalent to Equation (9). Hence, the reliability of component i at time t in state m can be obtained by summing the stochastic multi-value sequences S m i and S m i ( t 1 ) .
In a stochastic multi-value model for a dynamic multi-state weighted k-out-of-n system with repairable components (as shown in Figure 6), when the probability of component i in state m at time t, and P m i ( t ) is used for the inputs of the MMWN, then the reliability of the system can be obtained accordingly.

4. Analysis of Illustrative Examples

In this section, consider the multiple line transmission system proposed in Reference [1] to investigate the efficiency and the accuracy of the proposed SMV approach. As shown in Figure 7, power/oil is delivered from the source to five stations through six transmission lines. Any lines with weight/performance that characterizes the flow available at its different points connected to the stations can be considered as a multi-state component [1]. The system depicted in Figure 7 can be regarded as a multi-state weighted k-out-of-n system with n = 6, M = 5, where n is the number of multi-state components (lines), and M is the highest state of the lines. Each transmission line has six states. Different states of each transmission line i are described by different random weight vector w i consisting of w i j   , where w i j is the weight/performance of line i in state j, i ∊ [1, n] and j ∊ [1, M]. Different demands are required by different stations.
In order to investigate more complex systems, for the same structure as in Figure 7, larger values of n and M may be selected. The results are compared with those obtained by adopting the UGF [11,26] and FUGF methods [19,21]. The computer programs for all approaches are developed in MATLAB, and all simulations are run on a computer with a 3.4-GHz Intel microprocessor with 16 GB memory.

4.1. Analysis of a Multiple Line Transmission System with Non-Repairable Components

For a reliability evaluation of a multiple line transmission system using model I, the computational complexity of the UGF method is O ( ( M + 1 ) n ) [21]. For model II, the computational complexity of the UGF method for state j or a higher state is O ( ( M + 2 j ) n ) [19]. For a multiple line transmission system divided into n * subsystems, the computational complexities of the FUGF method are O ( ( M + 1 ) n * ) and O ( ( M * + 1 ) n * ) for model I and II, respectively [19], when n * is large enough ( M * is the maximum possible state in the subsystem). However, when n * is a small value, FUGF will incur a large computational overhead due to the clustering operation [19].
The computational complexity of the SMV approach for a multiple line transmission system is presented in this section. For reliability evaluation using model I, (n − 1)·L multiple-valued logic add operations and L MVEL operations are required; hence, the computational complexity of the SMV approach with sequences is O ( n · L ) for an accuracy indicated by Equation (7), where L is the number of multi-values in the sequence. For model II, (n − 1)·L multiple-valued logic add operations, L MVEL operations, and L MVS operations are required; hence, the computational complexity of the SMV approach is O ( ( n + 1 ) · L ) for an accuracy indicated by Equation (7).
Several examples are used to compare the efficiency and accuracy of the SMV approach with the UGF [11,26] and FUGF [19,21] methods. The central processing unit (CPU) time is obtained for n components, and the highest state value of component M. The weights of components are real values randomly selected from (0, 10), and ‘0’ indicates the weight of the component in state 0. The probability of component i in state j is randomly selected from (0, 1), and meets the requirement of j = 0 M p i j = 1 . The reliabilities obtained by different methods are compared in order to evaluate the accuracy of the SMV approach.

4.1.1. Model I

The run time of different methods are presented in Table 2 and Table 3, for a system with n = 6 and 12 components and a pre-defined weight threshold value K = 0.5 i = 0 n w i M . As shown in Table 1 and Table 2, the CPU time required by the UGF and FUGF methods increases with the number of component states M + 1. However, the CPU time using the SMV approach is not influenced by the number of component states, but increases with the length of stochastic sequences. When the system has six components, the UGF method is more efficient than the SMV approach which L (the sequence length) is 10 k (k =1000), only when the value of M is 10 or less. When the system has 12 components, the SMV approach which L is 1 k is faster than the UGF and FUGF methods for all M values.
When a system has six components with 15 states for each component, Table 3 illustrates the accuracy of the comparison between the FUGF and SMV approaches. The results reveal that absolute and relative errors calculated by the SMV approach which L is 10 k are smaller than that calculated by FUGF in all cases. In short, the accuracy of the SMV approach is higher than that of FUGF.

4.1.2. Model II

For this model, when a system has n = 6 and 12 components, the run time of different methods are shown in Table 4 and Table 5. The pre-defined weight K is 0.5 i = 0 n w i M , the value of l defined in Equation (2) is 2.
As revealed in Table 4, UGF and FUGF are faster than the SMV approach which L is 1 k or 10 k, when M is 5 or less. As shown in Table 5, when the system has 12 components, the SMV approach which L is 1 k or 10 k is more efficient than the UGF and FUGF methods for all M values. The results in Table 4 and Table 5 show that the run time of the UGF and FUGF methods increases with the number of components n and states M + 1, and the run time of the SMV approach increases with the number of components n and the length of the sequence. As shown in Table 6, when the system has six components with 15 states, the system reliability obtained by the SMV approach which L is 10 k is more accurate than that obtained by FUGF.

4.2. Analysis of a Multiple Line Transmission System with Repairable Components

An example is introduced to validate the effectiveness of the proposed stochastic multi-value model in Figure 6. Similar to the system structure shown in Figure 7, a dynamic multi-state line transmission system is considered here with six repairable components/transmission lines and five stations. Each component has six possible states. It is assumed that five time periods have been considered for the working period of the system. The weights of each component in each state are provided in Table 7.
The state transition matrix for component i ( STM i ) denotes the transition probabilities of component i.
STM   1 = [ 0.2 0.15 0.25 0.15 0.1 0.15 0.1 0.5 0.1 0.15 0.05 0.1 0.05 0.05 0.55 0.15 0.1 0.1 0.03 0.1 0.17 0.6 0.05 0.05 0.03 0.07 0.2 0.15 0.45 0.1 0.05 0.05 0.1 0.2 0.2 0.4 ] , STM   2 = [ 0.4 0.2 0.1 0.15 0.1 0.05 0.1 0.45 0.15 0.15 0.1 0.05 0.05 0.05 0.5 0.25 0.1 0.05 0.06 0.14 0.2 0.5 0.05 0.05 0.08 0.1 0.12 0.2 0.4 0.1 0.05 0.1 0.15 0.2 0.1 0.4 ]
STM   3 = [ 0.4 0.2 0.15 0.1 0.1 0.05 0.1 0.5 0.15 0.15 0.05 0.05 0.1 0.2 0.4 0.15 0.05 0.1 0.05 0.1 0.15 0.5 0.15 0.05 0.05 0.05 0.1 0.15 0.5 0.15 0.05 0.05 0.1 0.1 0.15 0.55 ] , STM   4 = [ 0.45 0.2 0.15 0.1 0.05 0.05 0.15 0.5 0.15 0.1 0.05 0.05 0.05 0.1 0.6 0.1 0.1 0.05 0.05 0.15 0.1 0.55 0.1 0.05 0.1 0.1 0.05 0.15 0.5 0.1 0.05 0.1 0.15 0.1 0.05 0.55 ]
STM   5 = [ 0.35 0.25 0.15 0.1 0.1 0.05 0.1 0.5 0.1 0.15 0.05 0.1 0.05 0.15 0.5 0.15 0.1 0.05 0.2 0.1 0.05 0.55 0.05 0.05 0.05 0.05 0.2 0.2 0.45 0.05 0.1 0.1 0.05 0.05 0.2 0.5 ] , STM   6 = [ 0.5 0.2 0.1 0.1 0.05 0.05 0.15 0.55 0.1 0.1 0.05 0.05 0.1 0.1 0.5 0.15 0.1 0.05 0.06 0.13 0.21 0.5 0.05 0.05 0.05 0.05 0.1 0.5 0.4 0.1 0.05 0.05 0.1 0.1 0.15 0.55 ]
The reliability and accuracy of model I and model II systems in each period using the UGF, FUGF, and SMV methods are provided in Table 8 and Table 9. Accuracy is defined as the ratio of the disparity between an approximate reliability and the accurate value over the accurate result. The pre-defined weight K is 20 in the system of model I and model II. In model II, a component does not make a contribution to the system when the states of the components are below j, and the weight threshold in component state j is set to be 2. From Table 8 and Table 9, the results indicate that the SMV approach which L is 1 k or 10 k is faster than the UGF method for the model I and model II systems. The SMV approach which L is 1 k or 10 k is more efficient and more accurate than the FUGF method for the systems of model I and model II.
For a multi-state weighted k-out-of-n system with repairable components, a (M + 1) × (M + 1) state transition matrix (STM) is provided for each component (M is the maximum possible state of each component), resulting in a complexity of O ( T ( M + 1 ) n ) and O ( T ( M + 2 j ) n ) by the UGF method to obtain the system reliability of model I and model II, respectively. The complexity of the FUGF method can be expressed as O ( T ( M + 1 ) n * ) and O ( T ( M * + 1 ) n * ) when the system model I and model II have n * subsystems, where T is the number of the time period, and m * is the maximum possible state in the subsystem. However, a computational complexity of O ( n T L ) is required to calculate the PD of the system at each time period using the SMV approach. Then the reliability of the system can be obtained by the comparison of the PD of the system and the pre-defined value K (the PD of six components is presented in the Appendix A, where L is the length of the randomly permuted multiple-valued sequence used in the SMV approach).

5. Conclusions

Computational overhead is a key challenge in the evaluation of the reliability of multi-state k-out-of-n systems with large numbers of components and states that can describe the behavior of multiple line transmission systems (e.g., power/oil transmission systems). In addition, the exact values of system reliability are not always necessary. This work therefore proposes an SMV approach to approximately evaluate the reliability of multi-state k-out-of-n systems. Two stochastic multi-value models are presented for steady state and dynamic multi-state k-out-of-n systems, respectively. The efficiency and accuracy of the proposed models are compared with the UGF and FUGF methods.
The results indicate that the run time of the SMV approach increases with the length of the sequences and the number of components, while the run time required by UGF and FUGF increases with the number of components and the number of components’ states. Furthermore, as shown in the analysis of computational complexities of SMV, UGF, and FUGF methods, the number of component states is not a crucial factor that affects the run time in the reliability evaluation using the SMV approach compared to the use of the UGF and FUGF methods. The SMV approach is more efficient than the UGF and FUGF methods for a complex system with a larger number of component states. Due to the influence of component states, an SMV approach with L = 10 k is more accurate than the FUGF method for evaluating the reliability of complex multi-state k-out-of-n systems.

Acknowledgments

This research is partly supported by the Project of the National Natural Science Foundation of China (Grant No. 61371024 and No. 61601371), the Aerospace Science Technology Fund, the Fundamental Research Funds for the Central University under Grant 3102016QD042, Shaanxi Science and Technology Co-ordination and Innovation Project under Grant 2016KZTDGY02-01 and the Natural Sciences and Engineering Research Council (NSERC) of Canada.

Author Contributions

Xiaogang Song designed the SMV models, drafted the manuscript; Zhengjun Zhai carried out the data acquisition, performed the experiments; Yangming Guo analyzed the data; Peican Zhu and Jie Han reviewed and refined the paper.

Conflicts of Interest

The authors declared no conflicts of interest with respect to the research, authorship, and/or publication of this article.

Appendix A

For a dynamic multi-state weighted k-out-of-n system with repairable components, as shown in Figure 7, with six components and six states of each component, the PD of components at each time period obtained by the SMV approach are presented in Table A1, Table A2, Table A3, Table A4, Table A5 and Table A6 (sequence length L = 10 k).
Table A1. Probability distribution of component 1 using the SMV approach.
Table A1. Probability distribution of component 1 using the SMV approach.
Period012345
State
000.050.0520.05320.05460.0556
100.050.09150.11330.12370.1284
200.10.18650.22970.24810.2552
300.20.260.27760.28260.2839
400.20.19750.17280.15630.1479
510.40.21250.15340.13470.1290
Table A2. Probability distribution of component 2 using the SMV approach.
Table A2. Probability distribution of component 2 using the SMV approach.
Period012345
State
000.050.07750.09040.09590.0983
100.10.14050.1570.16370.1664
200.150.2070.2280.23550.238
300.20.260.27740.28230.2835
400.10.120.1230.1230.1228
510.40.1950.12420.09960.091
Table A3. Probability distribution of component 3 using the SMV approach.
Table A3. Probability distribution of component 3 using the SMV approach.
Period012345
State
000.050.0750.08830.09560.0997
100.050.10.1350.15690.17
200.10.140.15850.16790.1729
300.10.1550.18320.19730.2043
400.150.1850.1870.18170.1763
510.550.3450.2480.20060.1768
Table A4. Probability distribution of component 4 using the SMV approach.
Table A4. Probability distribution of component 4 using the SMV approach.
Period012345
State
000.050.08250.10230.11380.1203
100.10.150.17560.18900.1961
200.150.20750.22750.23320.2341
300.10.14750.17060.18210.1878
400.050.0850.1060.11760.1237
510.550.32750.2180.16430.1380
Table A5. Probability distribution of component 5 using the SMV approach.
Table A5. Probability distribution of component 5 using the SMV approach.
Period012345
State
000.10.11750.12540.13190.1367
100.10.14750.17190.18580.1942
200.050.11750.15390.16870.1734
300.050.1250.17670.20550.2199
400.20.21250.18870.1670.153
510.50.280.18340.14110.1228
Table A6. Probability distribution of component 6 using the SMV approach.
Table A6. Probability distribution of component 6 using the SMV approach.
Period012345
State
000.050.08350.10630.12170.1319
100.050.09550.13060.15530.1716
200.10.1510.1780.1920.199
300.10.160.18930.20170.2061
400.150.17750.17070.15820.1479
510.550.33250.22510.17110.1435

References

  1. Levitin, G. Multi-state vector-k-out-of-n systems. IEEE Trans. Reliab. 2013, 62, 648–656. [Google Scholar] [CrossRef]
  2. Behr, A.; Camarinopoulos, L. Two formulas for computing the reliability of incomplete k-out-of-n: G systems. IEEE Trans. Reliab. 1997, 46, 421–429. [Google Scholar] [CrossRef]
  3. Chaturvedi, S.K.; Basha, S.B.; Amari, S.V.; Zuo, M.J. Reliability analysis of generalized multi-state k-out-of-n systems. J. Risk Reliab. 2012, 226, 327–336. [Google Scholar] [CrossRef]
  4. Wang, Z.Q.; He, J.H.; Nechifor, A.; Zhang, D.H.; Crossley, P. Identification of critical transmission lines in complex power networks. Energies 2017, 10, 1294. [Google Scholar] [CrossRef]
  5. Tian, Z.G.; Zuo, M.J.; Yam, R.C.M. Multi-state k-out-of-n systems and their performance evaluation. IIE Trans. 2009, 41, 32–44. [Google Scholar] [CrossRef]
  6. Huang, J.S.; Zuo, M.J.; Wu, Y.H. Generalized multi-state k-out-of-n: G systems. IEEE Trans. Reliab. 2000, 49, 105–111. [Google Scholar] [CrossRef]
  7. Ding, Y.; Zio, E.; Li, Y.; Cheng, L.; Wu, Q. Definition of multi-state weighted k-out-of-n: F systems. Int. J. Perform. Eng 2012, 8, 217–219. [Google Scholar]
  8. Eryilmaz, S. On reliability analysis of a k-out-of-n system with components having random weights. Reliab. Eng. Syst. Saf. 2013, 109, 41–44. [Google Scholar] [CrossRef]
  9. Chen, Y.; Yang, Q. Reliability of two-stage weighted k-out-of-n systems with components in common. IEEE Trans. Reliab. 2005, 54, 431–440. [Google Scholar] [CrossRef]
  10. Sarikaya, K.; Eryilmaz, S. Modeling and analysis of weighted k-out-of-n: G system consisting of two different types of components. J. Risk Reliab. 2014, 228, 265–271. [Google Scholar]
  11. Li, W.; Zuo, M.J. Reliability evaluation of multi-state weighted k-out-of-n systems. Reliab. Eng. Syst. Saf. 2008, 93, 160–167. [Google Scholar] [CrossRef]
  12. Zuo, M.J.; Tian, Z.G. Performance evaluation of generalized multi-state k-out-of-n systems. IEEE Trans. Reliab. 2006, 55, 319–327. [Google Scholar] [CrossRef]
  13. Ushakov, I. Optimal standby problem and a universal generating function. Sov. J. Comput. Syst. Sci. 1987, 25, 61–73. [Google Scholar]
  14. Lisnianski, A.; Levitin, G.; Ben-Haim, H.; Elmakis, D. Power system structure optimization subject to reliability constraints. Electr. Power Syst. Res. 1996, 39, 145–152. [Google Scholar] [CrossRef]
  15. Levitin, G.; Lisnianski, A. Structure optimization of power system with bridge topology. Electr. Power Syst. Res. 1998, 45, 201–208. [Google Scholar] [CrossRef]
  16. Levitin, G.; Lisnianski, A. Realiability optimization for weighted voting system. Reliab. Eng. Syst. Saf. 2001, 71, 131–138. [Google Scholar] [CrossRef]
  17. Levitin, G.; Lisnianski, A. Structure optimization of multi-state system with two failure modes. Reliab. Eng. Syst. Saf. 2001, 72, 75–89. [Google Scholar] [CrossRef]
  18. Levitin, G. Optimal series-parallel topology of multi-state system with two failure modes. Reliab. Eng. Syst. Saf. 2002, 77, 93–107. [Google Scholar] [CrossRef]
  19. Levitin, G. A universal generating function approach for the analysis of multi-state systems with dependent elements. Reliab. Eng. Syst. Saf. 2004, 84, 285–292. [Google Scholar] [CrossRef]
  20. Ding, Y.; Zuo, M.J.; Li, W. A framework for reliability approximation of multi-state weighted k-out-of-n systems. IEEE Trans. Reliab. 2010, 59, 297–308. [Google Scholar] [CrossRef]
  21. Ding, Y.; Lisnianski, A. Fuzzy universal generating functions for multi-state system reliability assessment. Fuzzy Sets Syst. 2008, 159, 307–324. [Google Scholar] [CrossRef]
  22. Singer, D. A fuzzy set approach to fault tree and reliability analysis. Fuzzy Sets Syst. 1990, 34, 145–155. [Google Scholar] [CrossRef]
  23. Purba, J.H.; Lu, J.; Zhang, G.; Pedrycz, W. A fuzzy reliability assessment of basic events of fault trees through qualitative data processing. Fuzzy Sets Syst. 2014, 243, 50–69. [Google Scholar] [CrossRef]
  24. Kao, Y.T.; Zahara, E.; Kao, I.W. A hybridized approach to data clustering. Expert Syst. Appl. 2008, 34, 1754–1762. [Google Scholar] [CrossRef]
  25. Kotowrocki, K.; Kwiatuszewska-Sarnecka, B. Reliability and risk analysis of large systems with aging components. Reliab. Eng. Syst. Saf. 2008, 93, 1821–1829. [Google Scholar] [CrossRef]
  26. Khorshidi, H.A.; Gunawan, I.; Ibrahim, M.Y. On reliability evaluation of multistate weighted k-out-of-n system using present value. Eng. Econ. 2015, 60, 22–39. [Google Scholar] [CrossRef]
  27. Han, J.; Chen, H.; Liang, J.; Zhu, P.C.; Yang, Z.; Lombardi, F. A stochastic computational approach for accurate and efficient reliability evaluation. IEEE Trans. Comput. 2013, 63, 1336–1350. [Google Scholar] [CrossRef]
  28. Song, X.G.; Zhai, Z.J.; Zhu, P.C.; Guo, Y.M.; Zhang, Y.P. Approximate Analysis of Multi-stated Weighted Majority Systems. In Proceedings of the 2017 Prognostics and System Health Management Conference (PHM-Harbin), Harbin, China, 9–12 July 2017; pp. 1–6. [Google Scholar]
  29. Heideman, M.T. Convolution and Polynomial Multiplication. In Multiplicative Complexity, Convolution, and the DFT; Springer: New York, NY, USA, 1988. [Google Scholar]
  30. Zhu, P.C.; Han, J. Stochastic Multiple-Valued Gene Networks. IEEE Trans. Biomed. Circuits Syst. 2014, 8, 42–53. [Google Scholar] [PubMed]
  31. Hogg, R.V.; McKean, J.W.; Craig, A.T. Introduction to Mathematical Statistics: 6th (sixth) Edition; Prentice Hall: Upper Saddle River, NJ, USA, 2004. [Google Scholar]
Figure 1. An illustration of the encoding process of a ternary-valued probability vector with a 10 digit sequence of 0, 1, 2.
Figure 1. An illustration of the encoding process of a ternary-valued probability vector with a 10 digit sequence of 0, 1, 2.
Energies 10 01740 g001
Figure 2. Stochastic logic gates: (a) a ternary-valued inverter; (b) an MVS logic; (c) an MVEL logic; (d) a 4-to-1 multiplexer.
Figure 2. Stochastic logic gates: (a) a ternary-valued inverter; (b) an MVS logic; (c) an MVEL logic; (d) a 4-to-1 multiplexer.
Energies 10 01740 g002
Figure 3. The stochastic encoding of the weights and reliabilities of component i using a multi-valued sequence with sequence length L = 10.
Figure 3. The stochastic encoding of the weights and reliabilities of component i using a multi-valued sequence with sequence length L = 10.
Energies 10 01740 g003
Figure 4. The stochastic multi-valued model for a multi-state weighted k-out-of-n system consisting of non-repairable components.
Figure 4. The stochastic multi-valued model for a multi-state weighted k-out-of-n system consisting of non-repairable components.
Energies 10 01740 g004
Figure 5. Different states of a component i during the time period T.
Figure 5. Different states of a component i during the time period T.
Energies 10 01740 g005
Figure 6. The stochastic multi-value model for a dynamic multi-state weighted k-out-of-n system with repairable components.
Figure 6. The stochastic multi-value model for a dynamic multi-state weighted k-out-of-n system with repairable components.
Energies 10 01740 g006
Figure 7. Multiple line transmission system [1].
Figure 7. Multiple line transmission system [1].
Energies 10 01740 g007
Table 1. Efficiency comparison for a system of model I with six components.
Table 1. Efficiency comparison for a system of model I with six components.
The M ValueCPU Time (s) by UGF (T1)CPU Time (s) by FUGF (T2)CPU Time (s) by SMV Approach (T3)
L = 1 kL = 10 k
50.003830.801630.020260.21170
100.103561.920380.020490.21593
150.404863.740180.021280.21545
202.329114.607910.020230.22064
2510.90985.403700.020180.21960
3031.40166.970950.021040.22146
Table 2. Efficiency comparison for a system of model I with 12 components.
Table 2. Efficiency comparison for a system of model I with 12 components.
The M ValueCPU Time (s) by UGF (T1)CPU Time (s) by FUGF (T2)CPU Time (s) by SMV Approach (T3)
L = 1 kL = 10 k
56.41411.42040.053720.54842
8726.374.73410.054470.55142
106173.6216.28190.053810.55647
12/53.39250.055230.56025
15/201.82180.056950.56324
Table 3. Accuracy of the SMV approach and FUGF [19,21], compared with UGF [11,26], when a system of model I has six components with 15 states.
Table 3. Accuracy of the SMV approach and FUGF [19,21], compared with UGF [11,26], when a system of model I has six components with 15 states.
The kj ValueReliability by UGFReliability by FUGFReliability by SMV Approach with L = 10 kAbsolute/Relative Error by FUGFAbsolute/Relative Error by SMV Approach with L = 10 k
01.00001.00001.00000/0%0/0%
100.99200.99130.99200.0007/0.071%0/0%
200.77270.74680.77160.0059/0.763%0.0011/0.142%
300.24610.24140.24400.0047/1.909%0.0021/0.853%
400.09020.09550.09300.0053/5.875%0.0028/3.104%
500.00330.00380.00300.0005/15.15%0.0003/9.090%
600.000001000.000001/0%0.000001/0%
Table 4. Efficiency comparison for a system of model II with six components.
Table 4. Efficiency comparison for a system of model II with six components.
The M ValueCPU Time (s) by UGF (T1)CPU Time (s) by FUGF (T2)CPU Time (s) by SMV Approach (T3)
L = 1 kL = 10 k
50.002610.213520.027170.28382
100.097040.524510.028020.28211
150.373631.37360.028290.28575
201.80752.14170.028740.28298
256.18653.54250.029390.28638
3019.23744.77210.029850.28673
Table 5. Efficiency comparison for a system of model II with 12 components.
Table 5. Efficiency comparison for a system of model II with 12 components.
The M ValueCPU Time (s) by UGF (T1)CPU Time (s) by FUGF (T2)CPU Time (s) by SMV Approach (T3)
L = 1 kL = 10 k
50.082630.968460.061190.65196
81.53271.24580.061610.65514
102.16822.63820.067930.65930
1218.94353.79360.065340.66064
1522.39495.83950.067590.66199
Table 6. Accuracy of the SMV approach and FUGF [19,21], compared with UGF [11,26], when a system of model II has six components with 15 states.
Table 6. Accuracy of the SMV approach and FUGF [19,21], compared with UGF [11,26], when a system of model II has six components with 15 states.
The kj ValueReliability by UGFReliability by FUGFReliability by SMV Approach with L = 10 kAbsolute/Relative Error by FUGFAbsolute/Relative Error by SMV Approach with L = 10 k
01.00001.00001.00000/0%0/0%
100.98970.99860.98940.0011/0.111%0.0003/0.030%
200.69460.69030.69240.0043/0.619%0.0022/0.316%
300.22750.22040.22460.0071/3.120%0.0029/1.274%
400.07740.07310.07690.0043/5.555%0.0025/3.229%
500.00270.00200.00240.0007/25.92%0.0003/11.11%
600.000001000.000001/0%0.000001/0%
Table 7. The weights/performance of each component in each state.
Table 7. The weights/performance of each component in each state.
State012345
Component (Line)
1023467
2012456
3012356
4013467
5012345
6034567
Table 8. The reliability and accuracy of a dynamic system of mode I in each period using UGF, FUGF, and SMV methods; L: The sequence length for the SMV approach.
Table 8. The reliability and accuracy of a dynamic system of mode I in each period using UGF, FUGF, and SMV methods; L: The sequence length for the SMV approach.
Reliability/Accuracy in Each PeriodCPU Time (s)
012345
UGF [11,26]10.95570.80740.67170.58700.54010.4097
FUGF [19,21]1/0%0.9551/
0.063%
0.8091/
0.211%
0.6729/
0.179%
0.5852/
0.29%
0.5424/
0.424%
1.3267
SMV approach with L = 1 k1/0%0.9549/
0.083%
0.8069/
0.062%
0.6720/
0.045%
0.5864/
0.102%
0.5409/
0.123%
0.0912
SMV approach with L = 10 k1/0%0.9557/
0.0%
0.8075/
0.012%
0.6715/
0.029%
0.5868/
0.034%
0.5403/
0.037%
0.3571
Table 9. The reliability and accuracy of a dynamic system of mode II in each period using UGF, FUGF, and SMV methods; L: The sequence length for the SMV approach.
Table 9. The reliability and accuracy of a dynamic system of mode II in each period using UGF, FUGF, and SMV methods; L: The sequence length for the SMV approach.
Reliability/Accuracy in Each PeriodCPU Time (s)
012345
UGF [11,26]10.94070.76560.61850.53100.48370.4372
FUGF [19,21]1/0%0.9423/
0.17%
0.7639/
0.222%
0.6162/
0.372%
0.5329/
0.358%
0.4811/
0.536%
1.3321
SMV approach with L = 1 k1/0%0.94/
0.074%
0.7648/
0.1045
0.6189/
0.065%
0.5316/
0.113%
0.4829/
0.165%
0.0936
SMV approach with L = 10 k1/0%0.9405/
0.021%
0.7657/
0.013%
0.6182/
0.049%
0.5313/
0.056%
0.4833/
0.083%
0.3794

Share and Cite

MDPI and ACS Style

Song, X.; Zhai, Z.; Guo, Y.; Zhu, P.; Han, J. Approximate Analysis of Multi-State Weighted k-Out-of-n Systems Applied to Transmission Lines. Energies 2017, 10, 1740. https://doi.org/10.3390/en10111740

AMA Style

Song X, Zhai Z, Guo Y, Zhu P, Han J. Approximate Analysis of Multi-State Weighted k-Out-of-n Systems Applied to Transmission Lines. Energies. 2017; 10(11):1740. https://doi.org/10.3390/en10111740

Chicago/Turabian Style

Song, Xiaogang, Zhengjun Zhai, Yangming Guo, Peican Zhu, and Jie Han. 2017. "Approximate Analysis of Multi-State Weighted k-Out-of-n Systems Applied to Transmission Lines" Energies 10, no. 11: 1740. https://doi.org/10.3390/en10111740

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop