Next Article in Journal
Floodplain Stability Indices for Sustainable Waterfront Development by Spatial Identification of Erosion and Deposition
Next Article in Special Issue
The Energy Rebound Effect for the Construction Industry: Empirical Evidence from China
Previous Article in Journal
Examining PM2.5 Emissions Embodied in China’s Supply Chain Using a Multiregional Input-Output Analysis
Previous Article in Special Issue
Carbon Dioxide Emissions, Economic Growth, and Selected Types of Fossil Energy Consumption in China: Empirical Evidence from 1965 to 2015
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

ESCoBox: A Set of Tools for Mini-Grid Sustainability in the Developing World

1
Institute of Energy and Sustainable Development, De Montfort University, Queens Building, The Gateway, Leicester LE1 9BH, UK
2
School of Electrical and Electronic Engineering, Newcastle University, Newcastle NE1 7RU, UK
*
Author to whom correspondence should be addressed.
Sustainability 2017, 9(5), 738; https://doi.org/10.3390/su9050738
Submission received: 5 April 2017 / Revised: 25 April 2017 / Accepted: 28 April 2017 / Published: 3 May 2017
(This article belongs to the Special Issue Energy Security and Sustainability)

Abstract

:
Mini-grids powered by photovoltaic generators or other renewable energy sources have the potential to bring electricity to the 17% of the world’s population, mainly in rural areas, that are currently un-served. However, designing and managing a mini-grid so that it is reliable and economically sustainable is difficult because of the high variability of demand that arises from the small population of consumers. We describe an integrated set of four tools to assist mini-grid operators to predict and manage demand. These comprise a decision support tool to predict peak and average demand from a consumer population, a demand disaggregation tool that allows the key statistical properties of connected electricity-consuming appliances to be identified, a battery condition modeling tool which allows the impact on battery life of a planned operating regime to be predicted and a demand control sub-system which limits the operating time of high demand appliances to intervals when they can be supported. Results from application of the tool set to mini-grids in Kenya and The Gambia are presented. We conclude that accessible, usable and low cost tools of this form can improve mini-grid sustainability.

1. Introduction

Currently, 1.2 billion people (about 17% of the world’s population) do not have access to electricity [1]. The vast majority of these are in rural communities in non-OECD countries. Even where grid connections are available, the reliability of access is often poor—for example in Nigeria 96% of households are connected but only 18% of those connections function for more than half the time [2]. Electricity is so central to the functioning of modern lifestyles that economic opportunities and quality of life are severely constrained by the lack of reliable access to it [3]. Operational experience and research evidence is accumulating to show that a conventional grid system based on large scale generation plant with extensive high voltage high capacity transmission and distribution networks is not a practical or economic method of meeting all these needs, particularly in Africa [4]. In addition, it is clear that with the global need to reduce carbon emissions by adopting renewable energy resources that are inherently geographically distributed, localization of electricity generation and use becomes economically beneficial and is being adopted in developed countries with mature grid systems [5].
These arguments make mini- or micro-grids attractive as a way forward for rural electrification that has been vigorously promoted as a “high impact opportunity” by the United Nations and World Bank joint initiative Sustainable Energy for All (SE4All) [6]. Such grids will serve a local community with renewably-generated electricity and either have no connection to a national grid system at all (hence off-grid) or have a connection that may be either severely limited in capacity relative to the local demand or unreliable. The potential for mini-grids to meet the needs of this un-served population has been shown by many practical demonstration projects [7] and start-up enterprises [8], but large scale rollout of mini-grid systems has not yet happened. Many of these pilot systems have been difficult to implement or not proved sustainable so investors have been deterred from supporting replication. This experience contrasts with, for example, the relatively rapid roll-out of mobile phone technology and the uptake of solar home systems in some countries, notably Bangladesh with four million installed [9].
A review by Hazelton et al. [10] identifies a range of technical, economic, and regulatory risks faced by photovoltaic (PV) powered mini-grids, most of which are applicable to systems powered by other renewable sources. Of the technical risks, the most prominent is “load uncertainty”—the difficulty of predicting and managing the total electrical load presented by a mini-grid’s customers. Battery lifetime, equipment reliability, and compatibility of system components are also identified. The latter two are being resolved as standards mature but battery storage continues to present cost and durability issues for mini-grid operators [11]. The interplay between generation resource, energy storage capacity and the behavior of demand customers was examined in a Rwandan setting by Crossland et al. [12] with the conclusion that all these factors need to be considered together in both system design and operation.
This paper presents a set of four tools and techniques for mini-grid planning and operation that address the two critical technical issues of load uncertainty and battery lifetime. They have been developed under a project entitled ESCoBox with the goal of reducing the cost of energy access by improving both system reliability and economic sustainability for rural mini-grids. The rest of the paper is structured as follows. In Section 2, we describe the overall concept of the ESCoBox toolset and the theoretical background to each of the individual tools. Section 3 covers the practical implementation and application methods of each tool. Section 4 reports the results of initial field trials in the developing world. The potential for use and improvement of these tools is then discussed in Section 5, followed by overall conclusions.

2. The ESCoBox Concept

2.1. System Overview

The challenge for mini-grid planners is to size a system that will meet the needs of a community sufficiently to gain their engagement, at a capital and operating cost that can be recovered from consumers. While the initial installation cost may be partly subsidized, the costs of maintenance and renewal normally must be met from operating revenue. Operating the system close to capacity is desirable in terms of generating income and keeping the unit cost per kWh affordable, but overloading the system will result in brownouts or system failures and shorten battery life with a consequent high cost impact. Maintaining an optimum balance between supply and demand is particularly difficult for a mini-grid because of the high variability of demand arising from the small consumer population. The mathematical reasons for this are detailed in [13] and summarized in the next subsection. Often the only information a system manager has is a real-time indication of instantaneous generation and demand, which may in some cases be logged to give an operating history.
Thus, the core component of this toolset is software that can be used to predict peak and average electricity demand from a given population of consumers and their appliances. It is envisaged that this will be used in the planning stage to size the system and subsequently in operation to support decisions on whether to accept new consumer connections or appliance types, particularly higher consumption devices with income-generating value such as grain mills. For this reason, it is referred to as the decision support tool. Its use can be augmented where appropriate by two additional software components:
  • A demand disaggregation tool: This analyzes the demand profile on a consumer’s connection to determine the types and timing of appliance use. If performed on most of the connections served by a mini-grid, this can provide reasonably accurate data for predicting peak demand with the decision support tool, which otherwise relies heavily on survey data and the tool user’s judgment.
  • A battery condition modeling tool, which allows the impact on battery state and life expectancy to be predicted for a given daily generation and demand profile simulated by the decision support tool.
The final component in this toolset is the demand controller, a hardware and software subsystem which allows the time of operation of high demand appliances to be limited by the system manager. The need for this device is illustrated by Figure 1, which shows the aggregate demand profile measured for two days on a micro-hydro mini-grid in Malawi. The early evening peak around 6:00–9:00 p.m. arising from household lighting and appliances is very evident and is typical of mini-grid loads as it is of national grid systems. The system is capable of supplying this peak demand, but there is substantial unused capacity earlier in the day. That unused capacity could support valuable commercial uses, but to prevent system overload they must be constrained not to encroach on the evening peak. It is expected that users limited in this way would be offered some form of “off-peak” tariff. The decision support tool is designed to be used to quantify the capacity levels and time windows that can be sold in this way.

2.2. Decision Support Tool

The aggregate electrical demand presented at any time to the generator of a mini-grid will be composed of a number of individual loads arising from appliances that have been switched on, and will be switched off, at times determined by a human user or by some automated control responding to the environment of the power-consuming appliance. While there will be some correlation of operating times for loads with related functions, such as lighting coming on in the evening, as long as the decision taking processes that determine times of operation of each load are independent, the precise population of operating loads at any given time will be uncertain. For a micro-grid serving a small number of households each with just a few electricity consuming devices it is likely that at some time all will switched on and the maximum possible demand will be the sum of the loads drawn by all the available appliances. As the number of power-consuming households and businesses rises, and they start to collect a range of appliances for different purposes, the likelihood of every available appliance being presented simultaneously becomes negligible. The challenge then is to decide what maximum demand can be expected from a given population. The ratio between the maximum demand likely to occur in practice and the total possible demand is known as the diversity factor.
The simple heuristic formulae used by large scale grid operators to calculate maximum expected demand from diversity values averaged across large numbers of consumers are not suitable for mini-grid planning. This is a consequence of the central limit theorem, which states that the means of n independent samples drawn from any distribution with mean m and standard deviation σ will have an approximately normal distribution with a mean equal to m and a standard deviation equal to σ/√n. This implies that, as the number of electricity-consuming appliances n served by a grid increases, the variability of their total electricity consumption will decrease by a factor of 1/√n, benefiting large grids but ensuring high variability on mini-grids. The approach taken for the software tool described here is to simulate the aggregate consumer demand using a Monte Carlo method from three data elements:
  • the population N of each main type of electricity-consuming appliance expected or in use;
  • the typical load E presented by an example of each type; and
  • an assessment for each type of the probability p that it will be in use at a given time of day.
These data can be obtained by surveying consumers, or automatically from the demand disaggregation tool. The simulation takes each device in the population, and at each time interval determines randomly whether it is “on” or “off” with a probability p and power consumed when on E. A binomial distribution of on and off states for each appliance Xi is created over nt trials (time intervals):
Xi ~ bin (nt, pi)
Then, the time sequence of aggregate demand D is simply the sum of these distributions over all N appliances:
D = i = 1 i = N X i E i
The software then computes the mean and standard deviation of all the values of D in the set, and finds the maximum value Dmax. It also calculates the maximum possible demand Dposs that would occur if all the appliances were in use simultaneously. In order to keep the run time convenient, the default value for nt is set to 1000. This is sufficient to reveal the standard deviation with adequate accuracy but not the maximum expected demand, which for most cases is calculated using the normal distribution. This is a reasonable approximation to the binomial for N > 10 and allows the cumulative normal distribution to be used to estimate the maximum expected demand with a specified (small) risk that it will be exceeded [14,15]. For N < 10 and other ill-conditioned cases, Dmax or Dposs are used as the estimates of maximum expected demand.

2.3. Demand Disaggregation Tool

Demand disaggregation has been described as the “holy grail of energy efficiency” for its potential to inform consumers concerning the energy consumption of their individual appliances [16]. It has proven computationally challenging to implement in developed countries because of the vast range of devices in use. However, for a rural mini-grid, the problem is more tractable—we have found that valuable data for system management can be obtained. This software tool employs a Hidden Semi-Markov Model [17] in which a set of states Z represents possible combinations of active appliances, a set of emissions X represents the total power consumption for each state, and a transition matrix holds the probability Pr(i|j) of transition from one state to another. A modified form of the forward-backward algorithm proposed by Yu [18] is used to identify the most likely sequence of states in a time series of power measurements from a consumer connection and update the model parameters.
The most probable combination of active appliances is then mapped onto each state in the sequence, drawing on a database of appliance types known to be in use and the expected power consumption of each type. The mapping uses the expected power of each possible appliance combination EPi calculated as the sum of M different possible appliance values Pj, weighted by their probability Prj of being observed (where probabilities for an individual appliance type add up to 1),
E P i = j = 1 M P r j P j
Each of the N observed states with a power value PMi is then mapped to the nearest EPi and the sum of differences SD calculated:
S D = j = 1 N | E P i P M i |
The estimated power draws of the mapped appliances are then updated, and the process repeated to minimize SD. The overall processing flow of this tool is shown in Figure 2.

2.4. Battery Condition Modeling

The battery condition modeling tool employs an event-based general approach to engineering lifetime prediction known as a Wöhler curve [19]. In this application, approximate time-to-failure, expressed as a number L of charge/discharge cycles, can be related to the depth of discharge D at each cycle for a given battery technology [20]. A typical curve for a lead-acid battery is shown in Figure 3 derived from a manufacturer’s product specification [21]. These data can be used to derive curve parameters U0, U1, and U2 [22] to give a lifetime model of the form:
L = U 2 ( D r D ) U 0 e U 1 ( 1 D D r )
U2 is the rated number of life cycles at a reference depth of discharge Dr. The tool includes a representative set of parameters for different battery types.
For a battery of nominal capacity Cn kWh with rated life Lr cycles at depth of discharge Dr and cycle efficiency µ, the total potential lifetime charging energy throughput Etot is given by:
E tot = D r C n L r
At a different depth of discharge Di with corresponding life expectancy Li cycles, the fraction of Etot that is consumed by a further incremental discharge Ei giving rise to charge Ei/µ, is changed by a factor Fi = Lr/Li obtained by re-arrangement of Equation (3):
F i = ( D i D r ) U 0 e U 1 ( D i D r 1 )
Then, the fraction of life ∆Li (where whole life = 1) consumed by Ei is given by:
Δ L i = ( F i E i ) / ( E tot μ )
By summing the loss of life from each predicted discharge event an estimate can be calculated of the overall impact on expected battery lifetime of a particular operating regime. This approach provides a more realistic model of the impact of discharge events than the linear ∆Li = Ei/(Etotµ) embodied in the popular mini-grid planning tool HOMER [23,24].

2.5. Demand Control Sub-System

The demand control sub-system is conceptually simple, comprising a software component integrated with the decision support tool that allows the micro-grid manager to set the times that he or she will permit one or more high consumption appliances to run, having simulated their operation and verified that it is within available capacity. These times are then communicated to a microprocessor (the control node), which executes the schedule for each appliance on a radio-controlled power switch (a remotely-controlled socket) that is not accessible to the consumer. Figure 4 illustrates the sub-system architecture.

3. ESCoBox Implementation and Testing

3.1. Decision Support Tool

The decision support tool has been implemented as a Microsoft Excel spreadsheet with embedded software macros executing the algorithms described in Section 2. It may be downloaded from the project website [25] in two versions (the spreadsheets are protected to avoid accidental corruption; the password is ESCoBox–see Discussion Section for caveats). One is for power limited mini-grids such as micro-hydro and biomass systems where energy storage would take the form of a header reservoir and fuel store respectively, so no battery is required. This tool allows peak and average demand from a population of appliances to be modeled with available generator output power provided by the user. The second version is aimed at PV and battery mini-grids, and includes an estimate of the output over a day that can be expected from the PV generator given system parameters (day of year, location, weather, and system kWp). It also incorporates the battery condition model. A typical set of inputs and outputs from the simulation of non-controlled appliances using the PV version is shown in Figure 5.
The shaded cells (not green) in Figure 5 are for data entry. The appliance population is entered at top left, and then the probability of each appliance type operating on a given hour of the day is entered against the hour, with zero or very low probability hours left blank. System parameters, the location, date, and weather selected from drop-down options are entered in the pink shaded cells. When the simulation is run, the expected peak and average loads for the day, PV generation, and impact on battery life are calculated for each hour and plotted. If the results indicate a risk to the stable operation of the system, the predominantly green results cells visible in Figure 5 turn progressively from green to red depending on the severity of the risk.
A second form of simulation is provided by the tool for planning the operation of loads controlled by the demand control sub-system. This is shown in Figure 6. The appliances are entered individually at top left and assigned to a switch number. Their probability of operation during their assigned operating window is entered as before against the hour of the day. This simulation also allows operation of a fuel powered generator to be included where it is available and its most effective operating time and power level to be determined. When this simulation is run, the expected peak and average loads for the day (including both uncontrolled and controlled loads), total generation (PV plus genset), and impact on battery life are calculated for each hour and plotted. The result cells are similarly color coded for system risk from green to red as for the first simulation. A costing function is included in both simulations allowing the revenue from “anytime” and “off-peak” loads to be predicted and the cost of any generator runtime.

3.2. Demand Disaggregation Tool

The initial realization of this tool is in Matlab, as this allowed published code from Yu [18] to be employed. The complete tool code can be found in [26]. Given a dataset of power consumption by each user of a mini-grid over at least 20 days, it is able to produce an output file in comma-separated variable (csv) format containing the power consumed by each appliance observed and its probability of use for each hour of the day. The Decision Support Tool imports these data if given the filename thereby avoiding the need for manual data entry.
To validate the accuracy of the disaggregation, laboratory testing employed four lamps (two LED and two halogen) of power draw 3.8 W, 3.7 W, 36.9 W and 31.4 W that were connected to a monitored socket. Each was switched on and off in a known sequence, derived from mini-grid monitoring data to ensure realism, while the overall power consumption was monitored. The performance on this test is shown in Table 1; the algorithms had an overall accuracy of 92.4%. The algorithms were unable to differentiate between the two low energy lamps, but estimated their combined state with an accuracy of 93.9%.

3.3. Battery Condition Modeling

The battery condition modeling method described in Section 2 is implemented in the Decision Support Tool for PV and battery systems. It accepts as inputs the battery chemistry type, nominal capacity, cycle efficiency, and charge state at the beginning of the simulated day. This is required because the tool simulates one day at a time without retaining history. When the tool is run, the viability of the proposed consumer load and battery charge profile is indicated by the battery charge state in each hour and an estimate of the expected life of the battery if this cycle is repeated. These parameters change from green to red to indicate the sustainability of the operating plan.
The estimate of battery life assumes that the user is starting with a new battery and that the daily profile calculated is repeated indefinitely. In order to provide a realistic estimate of the possible charge fraction at the end of the day and battery lifetime, the battery charge fraction indicated at the end of each hour assumes that the power supplied to consumers over the hour is equal to the average demand power plus one standard deviation. The user is advised to schedule loads so that the charge fraction at the start of the day is achieved or exceeded by the end of the day.

3.4. Demand Control Sub-System

This has been implemented using a Raspberry Pi single board Linux computer to host an appliance control program which accepts appliance operating schedules either by manual entry on a web server interface or by reading the decision support tool spreadsheet cells that contain a valid schedule. It then signals on and off states by short range radio to up to six “smart plugs” each of which switches a controlled appliance on or off. The radio uses amplitude shift keying in the 433 MHz low power device band [27]. Figure 7 shows the switching element—it is configured so that one of the 13 A sockets has a permanent supply with a restricted current limit so can be used for low consumption purposes such as phone charging, while the other socket can support high power but is time limited under remote control. The cost of the computer and a single remote unit as shown is about $65.

4. Field Trials

Data from a PV-powered mini-grid on Mageta Island, Lake Victoria, Kenya (provided courtesy of SteamaCo Ltd., Kisumu, Kenya) was used to exercise the toolset (excluding the control sub-system) on a fully operational system. This system primarily serves a variety of commercial customers including bars, video halls, and fish merchants. The 28 kWh battery and control plant with 4.8 kWp of PV panels overhead is shown in Figure 8a while Figure 8b depicts the premises of a video hall. The disaggregation tool was employed to analyze the appliance use of all the consumers—Figure 9 illustrates the disaggregation of the appliances used by the video hall showing the probability of each appliance operating at each hour of the day. Because the clients are fishermen who fish at night, the business is most active during the day providing good alignment with PV generation.
The disaggregated data were imported into the decision support tool giving the results shown in Figure 10 for a day with clear sun. It can be seen that, in these conditions, there is ample generation to meet demand and ensure that the battery charge state is higher at the end of the day than at the start. There is also spare generation capacity from midday to late afternoon which could be used to supply loads constrained to that period so that battery charging is not affected. If the simulation is re-run for a stormy day of the kind that does occur on Lake Victoria the battery charge state at the end of the day falls to 0.67—a manageable outcome as long as there is not a run of such days. Overall, the system is lightly loaded and there is scope for the system manager to permit time-controlled loads in the period 11:00–17:00.
In contrast to the relatively robust performance of the Mageta Island system, application of the decision support tool to an operational but unreliable micro-grid system supplying a community center in The Gambia showed the kind of scenario that can arise when the system manager is unable to resist consumer pressure to accept connection of higher power appliances—in this case a water heating urn. Figure 11 shows the results. Although the average daily consumption of 6 kWh was well within the day’s generation of 9 kWh, the deep discharge caused by the occasional peak loads was drastically shortening battery life and also overloading the inverter.
Following analysis using the decision support tool and discussion with users, the PV capacity of this micro-grid was increased to 1.75 kWp, the operation of the television was time-limited using a demand control unit as shown in Figure 7, and the water heating urn was replaced with a bottled gas heating ring. This gave operating profiles as shown in Figure 12—note the y-axis scale is expanded. The system is now operating reliably and the manager plans to open a video hall similar to that described above for Mageta Island which will generate revenue and allow further improvements.
The operating economics of a micro-grid such as this can be summarized as follows. The installed capital cost of the PV system for an aid agency or other funding body would be about $3500, of which the batteries cost about $800. To deploy the tools described in this paper would cost an additional $360 for a simple laptop, Excel software, and the demand control sub-system with a single remote switch unit. The sustainable revenue shown in Figure 12 from a realistic per kWh tariff of GMD 40 (Gambian Dalassi where GMD45 = $1) is about $1600 per annum which is just about sufficient to pay for basic cleaning and maintenance and battery replacement. This compares with the subsidized tariff of GMD 10–11 offered by the national grid system in The Gambia [28], which has limited geographic coverage and cannot provide a 24-h service [29]. The operator will usually have opportunities to capture additional value from supplying electricity by offering services such as mobile phone charging and internet access. However a micro-grid at this scale can only repay its capital cost over a long term that is supportable by strategic investors such as governments, aid agencies, and targeted commercial schemes, e.g., the Microgrid Investment Accelerator [30].

5. Discussion

The results from the two trial sites presented above illustrate the potentially fragile nature of mini-grid systems and help to explain why their sustainability has proved challenging worldwide. Two studies, employing techniques similar to the authors’ Monte Carlo simulations at [13] that are the basis of the decision support tool, have further demonstrated the need for systematic load planning. Louie and Dauenhauer [31] show how errors in load forecasting leading to overload conditions have a severe effect on reliability, while Mandelli et al. [32] seek to mitigate the impact of load profile uncertainty in a system design method. A key point we have sought to keep in mind in this project is that however sound the initial design no mini-grid system can remain static in operation—the customer base and commercial pressures on the operator will evolve continuously and ideally the system capacity will need to expand as the customers prosper. The tools needed for ongoing operational management must therefore be low cost and easy to use. By publishing the code of these ESCoBox software tools we hope to stimulate further development under other projects. The usual caveat for open source software applies to all the code published with this paper, that it is offered in the hope that it is useful but no assurance of fitness for purpose is given.
There are unavoidably limitations to the accuracy of the predictions provided by this toolset. When used as part of the system design process, the designer will have imperfect knowledge about the appliances available to his potential customers, unless they possess none and an initial fit of lighting, phone charging, etc., is to be supplied as part of the project. A common approach is to perform a survey of the potential customer base to identify:
  • the appliances already owned that the system should accommodate;
  • those not owned but that the system operator should promote or supply (such as LED lights and efficient ceiling fans); and
  • higher power devices such as grain mills that are in use (possibly powered intermittently by fossil fuel generators) that can be served on a time controlled basis or not at all.
At the same time, the survey can acquire data concerning the likely frequency of appliance use that can be entered into the decision support tool. The designer’s judgment will have to be applied using knowledge of the customer community to moderate the survey findings and fill in gaps. This application of intuition and experience is unavoidable—it is often part of the design process for electrical installations in the developed world. Use of the tool to predict and plan a load profile, followed by experience of the actual operational outcome, will help to build the expertise to make these judgments.
Once a mini-grid system is in operation, if user electricity consumption is monitored on a sufficiently fine-grained basis, data disaggregation can be used as described above to obtain quite accurate data on appliance populations and frequency of use, allowing the decision support tool model to be kept up to date and capable of consistently useful predictions. The cloud-based mini-grid management systems offered by suppliers such as SteamaCo [8] and Powerhive [33] provide the opportunity to perform disaggregation as a cloud application and supply the results to operators on the ground.
The key limitation of the battery condition model as implemented in the decision support tool is that there is no memory in the model of the past operating regime so the single day snapshot it provides has to operate with an assumption of the charge state at the start of the day and a new battery. Clearly it would be desirable to integrate the model into a mini-grid supervisory system which would track the operating history. This is also a potential application to include in a cloud management system.

6. Conclusions

The long-term sustainability of a mini-grid system generally depends on the consumers paying the operator enough to support running costs and the cost of replacement of major components, particularly batteries, when that is unavoidable. This implies that the operator must permit a level of revenue-generating demand that is close to the system capacity but avoids overload conditions. They can only do this with an understanding of the impact of the decisions they take and the ability to regulate demand where necessary. Despite their limitations, the evidence from our trials is that the quantitative and rational approach to mini-grid management encouraged by these relatively simple tools can empower operators to strike a better balance between short-term revenue and long-term costs than is possible otherwise.

Acknowledgments

The authors would like to thank the Engineering and Physical Sciences Research Council (EPSRC) and Department for International Development for providing the financial support for this study under the ESCoBox (EP/L002566/1) project. The authors also wish to thank the following project partners: the University of Nairobi, the Institute of Development Studies, SteamaCo (Kisumu, Kenya, Practical Action Consulting, BBOXX and Ashden. We gratefully acknowledge the contributions of many community members in Kenya, Malawi, Nepal, The Gambia, Zimbabwe and Rwanda who have contributed vital knowledge and first-hand experience to the ESCoBox project team. We also thank the reviewers for their helpful comments.

Author Contributions

All authors have contributed equally to the ideas and developments described in this paper.

Conflicts of Interest

The authors declare no conflict of interest. The founding sponsors had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results.

References

  1. International Energy Agency. World Energy Outlook Executive Summary. 2016. Available online: https://www.iea.org/publications/freepublications/publication/WorldEnergyOutlook2016ExecutiveSummaryEnglish.pdf (accessed on 25 April 2017).
  2. Oyuke, A.; Halley Penar, P.; Howard, B. Off-Grid or ‘Off-On’: Lack of Access, Unreliable Electricity Supply Still Plague Majority of Africans. Afrobarometer. Dispatch 75. 2016. Available online: http://afrobarometer.org/sites/default/files/publications/Dispatches/ab_r6_dispatchno75_electricity_in_africa_eng1.pdf (accessed on 25 April 2017).
  3. Sovacool, B.K. The political economy of energy poverty: A review of key challenges. Energy Sustain. Dev. 2012, 16, 272–282. [Google Scholar] [CrossRef]
  4. Szabo, S.; Bodis, K.; Huld, T.; Moner-Girona, M. Sustainable energy planning: Leapfrogging the energy poverty gap in Africa. Renew. Sustain. Energy Rev. 2013, 28, 500–509. [Google Scholar] [CrossRef]
  5. Department of Energy and Climate Change. Community Energy Strategy; Full Report. 2014. Available online: https://www.gov.uk/government/publications/community-energy-strategy (accessed on 25 April 2017).
  6. Sustainable Energy for All. Clean Energy Mini-Grids. 2017. Available online: http://www.se4all.org/hio_clean-energy-mini-grids (accessed on 25 April 2017).
  7. Yadoo, A.; Cruickshank, H. The role for low carbon electrification technologies in poverty reduction and climate change strategies: A focus on renewable energy mini-grids with case studies in Nepal, Peru, and Kenya. Energy Policy 2012, 42, 591–602. [Google Scholar] [CrossRef]
  8. Steama.co. Connecting the Unconnected. 2017. Available online: http://steama.co/#connect-the-unconnected (accessed on 25 April 2017).
  9. Infrastructure Development Company Limited. Solar Home System Program. 2017. Available online: http://idcol.org/home/solar (accessed on 25 April 2017).
  10. Hazelton, J.E.; Bruce, A.G.; MacGill, I.F. A review of the potential benefits and risks of photovoltaic hybrid mini-grid systems. Renew. Energy 2014, 67, 222–229. [Google Scholar] [CrossRef]
  11. Adelmann, P. Existing Markets for Storage Systems in Off-Grid Applications. In Electrochemical Energy Storage for Renewable Sources and Grid Balancing; Moseley, P.T., Garche, J., Eds.; Elsevier: Amsterdam, The Netherlands, 2014; pp. 53–60. [Google Scholar]
  12. Crossland, A.F.; Anuta, O.H.; Wade, N.S. A socio-technical approach to increasing the battery lifetime of off-grid photovoltaic systems applied to a case study in Rwanda. Renew. Energy 2015, 83, 30–40. [Google Scholar] [CrossRef]
  13. Boait, P.; Advani, V.; Gammon, R. Estimation of demand diversity and daily demand profile for off-grid electrification in developing countries. Energy Sustain. Dev. 2015, 29, 135–141. [Google Scholar] [CrossRef]
  14. Wikipedia. Normal Distribution. Available online: https://en.wikipedia.org/wiki/Normal_distribution (accessed on 25 April 2017).
  15. Dowdy, S.; Wearden, S.; Chilko, D. Statistics for Research, 3rd ed.; Wiley: Hoboken, NY, USA, 2004; pp. 147–177. [Google Scholar]
  16. Carrie Armel, K.; Gupta, A.; Shrimali, G.; Albert, A. Is disaggregation the holy grail of energy efficiency? The case of electricity. Energy Policy 2013, 52, 213–234. [Google Scholar] [CrossRef]
  17. Yu, S. Hidden semi-Markov models. Art. Int. 2010, 174, 215–243. [Google Scholar] [CrossRef]
  18. Yu, S.; Kobayashi, H. An Efficient Forward-Backward Algorithm for an Explicit-Duration Hidden Markov Model. IEEE Signal Process. Lett. 2003, 10, 11–14. [Google Scholar]
  19. Wöhler, A. Theorie rechteckiger eiserner Brückenbalken mit Gitterwänden und mit Blechwänden. Zeitschrift für Bauwesen 1855, 5, 121–166. [Google Scholar]
  20. Sauer, D.U.; Wenzl, H. Comparison of different approaches for lifetime prediction of electrochemical systems using lead-acid batteries as example. J. Power Sources 2008, 176, 534–546. [Google Scholar] [CrossRef]
  21. Trojan Battery Co. Data Sheet for IND17-6V Industrial Line. Available online: http://www.trojanbattery.com/pdf/datasheets/IND17–6V_TrojanRE_Data_Sheets.pdf (accessed on 25 April 2017).
  22. Drouilhet, S.; Johnson, B.L. A battery life prediction method for hybrid power applications. In Proceedings of the 35th AIAA Aerospace Sciences Meeting and Exhibit, Reno, NV, USA, 6–9 January 1997; Available online: http://www.nrel.gov/docs/legosti/fy97/21978.pdf (accessed on 25 April 2017).
  23. Homer Energy. Battery Life Span. Available online: http://usersupport.homerenergy.com/customer/en/portal/articles/2187090-10020---battery-life-span (accessed on 25 April 2017).
  24. Hittinger, E.; Wiley, T.; Kluza, J.; Whitacre, J. Evaluating the value of batteries in microgrid electricity systems using an improved Energy Systems Model. Energy Convers. Manag. 2015, 89, 458–472. [Google Scholar] [CrossRef]
  25. ESCoBox Project Website. Available online: https://goo.gl/ABGdkF (accessed on 25 April 2017).
  26. Greenwood, D. Electricity Demand Disaggregation Code from the ESCoBox Project. Available online: https://github.com/David-Greenwood/ESCoBox (accessed on 25 April 2017).
  27. Energenie Raspberry Pi RF Transmitter Board. Available online: https://energenie4u.co.uk/res/pdfs/ENER314%20UM.pdf (accessed on 25 April 2017).
  28. Tariffs. Public Utilities Regulatory Authority. Available online: http://www.pura.gm/index.php?option=com_content&view=article&id=73&Itemid=98 (accessed on 25 April 2017).
  29. Gambia Information Site. NAWEC Gambia Limited. Available online: http://www.accessgambia.com/information/nawec-water-electricity.html (accessed on 25 April 2017).
  30. Microgrid Investment Accelerator. Scaling Investment in Clean Energy Microgrids. Available online: https://www.microgridinvest.org/ (accessed on 25 April 2017).
  31. Louie, H.; Dauenhauer, P. Effects of load estimation error on small-scale off-grid photovoltaic system design, cost and reliability. Energy Sustain. Dev. 2016, 34, 30–43. [Google Scholar] [CrossRef]
  32. Mandelli, S.; Brivio, C.; Colombo, E.; Merlo, M. Effect of load profile uncertainty on the optimum sizing of off-grid PV systems for rural electrification. Sustain. Energy Technol. Assess. 2016, 18, 34–47. [Google Scholar] [CrossRef]
  33. Powerhive (2017), Powerhive Technology. Available online: http://powerhive.com/our-technology/ (accessed on 25 April 2017).
Figure 1. Daily demand profiles from a micro-hydro system. Source: Practical Action.
Figure 1. Daily demand profiles from a micro-hydro system. Source: Practical Action.
Sustainability 09 00738 g001
Figure 2. Process flow of demand disaggregation software tool.
Figure 2. Process flow of demand disaggregation software tool.
Sustainability 09 00738 g002
Figure 3. Wöhler curve for lead-acid battery based on depth of discharge.
Figure 3. Wöhler curve for lead-acid battery based on depth of discharge.
Sustainability 09 00738 g003
Figure 4. Demand control sub-system.
Figure 4. Demand control sub-system.
Sustainability 09 00738 g004
Figure 5. Decision support tool display for uncontrolled appliances.
Figure 5. Decision support tool display for uncontrolled appliances.
Sustainability 09 00738 g005
Figure 6. Decision support tool display for controlled appliances.
Figure 6. Decision support tool display for controlled appliances.
Sustainability 09 00738 g006
Figure 7. Remote controlled socket unit.
Figure 7. Remote controlled socket unit.
Sustainability 09 00738 g007
Figure 8. PV mini-grid plant (a) and video hall (b), Mageta Island, Lake Victoria, Kenya.
Figure 8. PV mini-grid plant (a) and video hall (b), Mageta Island, Lake Victoria, Kenya.
Sustainability 09 00738 g008
Figure 9. Disaggregated appliance use (shown as probability of use in each hour of the day) by video hall, Mageta Island, Kenya.
Figure 9. Disaggregated appliance use (shown as probability of use in each hour of the day) by video hall, Mageta Island, Kenya.
Sustainability 09 00738 g009
Figure 10. Load profile and battery condition model from Mageta Island.
Figure 10. Load profile and battery condition model from Mageta Island.
Sustainability 09 00738 g010
Figure 11. Initial load profile and battery condition model from The Gambia.
Figure 11. Initial load profile and battery condition model from The Gambia.
Sustainability 09 00738 g011
Figure 12. Improved load profile and battery condition model from The Gambia.
Figure 12. Improved load profile and battery condition model from The Gambia.
Sustainability 09 00738 g012
Table 1. Laboratory test results from demand disaggregation.
Table 1. Laboratory test results from demand disaggregation.
ApplianceOn-State Accuracy %Overall Accuracy %
LED lamps85.293.9
Small halogen91.098.9
Large halogen84.198.6
State of system88.092.4

Share and Cite

MDPI and ACS Style

Boait, P.; Gammon, R.; Advani, V.; Wade, N.; Greenwood, D.; Davison, P. ESCoBox: A Set of Tools for Mini-Grid Sustainability in the Developing World. Sustainability 2017, 9, 738. https://doi.org/10.3390/su9050738

AMA Style

Boait P, Gammon R, Advani V, Wade N, Greenwood D, Davison P. ESCoBox: A Set of Tools for Mini-Grid Sustainability in the Developing World. Sustainability. 2017; 9(5):738. https://doi.org/10.3390/su9050738

Chicago/Turabian Style

Boait, Peter, Rupert Gammon, Varun Advani, Neal Wade, David Greenwood, and Peter Davison. 2017. "ESCoBox: A Set of Tools for Mini-Grid Sustainability in the Developing World" Sustainability 9, no. 5: 738. https://doi.org/10.3390/su9050738

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop