Article

Temporal Stability of the Velodyne HDL-64E S2 Scanner for High Accuracy Scanning Applications

1
Terrapoint USA Inc., 25216 Grogans Park Drive, The Woodlands, TX 77380, USA
2
Department of Geomatics Engineering, The University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada
*
Author to whom correspondence should be addressed.
Current Affiliation: Department of Civil & Environmental Engineering, The University of Houston, Room 2008, 3605 Cullen Blvd, Houston, TX 77204, USA
Remote Sens. 2011, 3(3), 539-553; https://doi.org/10.3390/rs3030539
Submission received: 10 February 2011 / Revised: 5 March 2011 / Accepted: 8 March 2011 / Published: 14 March 2011
(This article belongs to the Special Issue Terrestrial Laser Scanning)

Abstract

:
The temporal stability and static calibration and analysis of the Velodyne HDL‑64E S2 scanning LiDAR system is discussed and analyzed. The mathematical model for measurements for the HDL-64E S2 scanner is updated to include misalignments between the angular encoder and scanner axis of rotation, which are found to be a marginally significant source of error. It is reported that the horizontal and vertical laser offsets cannot reliably be obtained with the current calibration model due to their high correlation with the horizontal and vertical offsets. By analyzing observations from two separate HDL-64E S2 scanners it was found that the temporal stability of the horizontal angle offset is near the quantization level of the encoder, but the vertical angular offset, distance offset and distance scale are slightly larger than expected. This is felt to be due to long term variations in the scanner range, whose root cause is as of yet unidentified. Nevertheless, a temporally averaged calibration dataset for each of the scanners resulted in a 25% improvement in the 3D planar misclosure residual RMSE over the standard factory calibration model.

1. Introduction

The Velodyne HDL-64E S2 laser scanner was originally conceived for competition in the Defense Advanced Research Project Agency’s (DARPA) “Grand Challenge” which required autonomous vehicles to navigate across desert terrain, and then later through an urban environment. In fact, for the urban Grand Challenge the HDL-64E S2 was used by five of the six teams who finished successfully, including the first and second place finishers [1]. As a result of the Grand Challenge exposure, the Velodyne sensor has been a standard tool for developers of autonomous vehicles, robotics and automotive safety systems. Recently, however, this laser scanner has become a very popular choice for integration into kinematic mobile mapping platforms [1,2]. Evidence of this can be seen in its recent inclusion in the Google mobile mapping and smart car systems [3]. In addition, Topcon has also announced a kinematic mapping platform using the Velodyne laser scanner [4].
To date, most mapping applications of the Velodyne scanner have mainly targeted the medium accuracy (0.1 to 1.0 m 3D RMSE) GIS asset collection marketplace. The mobile mapping applications requiring the highest accuracy (i.e., <5 cm 3D RMSE) are mainly dominated by the systems centered on the Optech Lynx and Riegl VQ-250 laser scanners. The specifications of the Velodyne HDL-64E S2 do not match those of the Optech and Riegl scanners and therefore its use in high accuracy mobile scanning applications, such as railway and highway corridor surveys might be dismissed. However, to the authors’ knowledge no published kinematic accuracy analysis of the Velodyne HDL-64E S2 exists.
In previous work by the authors, presented in [5], some initial static calibration analyses of the Velodyne scanner were presented. It was found that a rigorous calibration of the scanner and a slight modification of the factory calibration model improved the overall accuracy of the point cloud obtained from the scanner by a factor of three. Final 3D RMS error of the scanner was on the order of 1.3 cm. This low noise level indicated that the scanner perhaps had potential as the basis of a high accuracy mobile mapping platform. However, there were still several questions remaining to verify that the scanner could consistently obtain the accuracy required.
The results and analysis presented herein extend upon the initial analyses in [5]. First, the remaining systemic errors noted in [5] are examined and their root cause identified. Some additional possible calibration parameters are also identified and examined. Next, the calibration of two different Velodyne HDL-64E S2 scanners is examined over time to determine the temporal stability of the calibration parameters for the scanner. The paper concludes with an examination of the overall temporal accuracy achievable with the scanner, which shows a 25% improvement in accuracy over the standard Velodyne factory calibration.

2. Mathematical Model of the Velodyne Scanner

The Velodyne laser scanner consists of a rotating head which contains 64 semiconductor lasers operating at a 905 nm wavelength and firing at up to 20,000 Hz, coupled with 64 dedicated photo detectors for precise ranging. The laser-detector pairs are precisely aligned at set vertical angles to give a 26.8° vertical field of view. The sensor head rotates at speeds up to 900 rpm (15 Hz) to give a full 360° field of view and captures up to 1.3 million points per second. Detailed specifications on the HDL-64E S2 can be found in [6]. A picture of the scanner is given in Figure 1.
Figure 1. The Velodyne HDL-64E S2 Scanner.
Figure 1. The Velodyne HDL-64E S2 Scanner.
Remotesensing 03 00539 g001
The computation of local scanner coordinates (x, y, z) for laser i of the Velodyne scanner is given by:
[ x y z ] = [ ( s i *R i + D o i ) * cos ( δ i ) * [ sin ( ε ) * cos ( β i ) cos ( ε ) * sin ( β i ) ] H o i * [ cos ( ε ) * cos ( β i ) + sin ( ε ) * sin ( β i ) ] ( s i *R i + D o i ) * cos ( δ i ) * [ cos ( ε ) * cos ( β i ) + sin ( ε ) * sin ( β i ) ] + H o i * [ sin ( ε ) * cos ( β i ) cos ( ε ) * sin ( β i ) ] ( s i *R i + D o i ) * sin ( δ i ) + V o i ]
where:
si
is the distance scale factor for laser i;
D o i
is the distance offset for laser i;
δi
is the vertical rotation correction for laser i;
βi
is the horizontal rotation correction for laser i;
H o i
is the horizontal offset from scanner frame origin for laser i;
V o i
is the vertical offset from scanner frame origin for laser i;
Ri
is the raw distance measurement from laser i;
ε
is the encoder angle measurement.
In the above model, the terms Ri and ε are the raw measurements provided by the scanner, whereas the other six parameters are instrument specific calibration values that are provided by Velodyne.
In examining the model for the Velodyne scanner and comparing the sensor to traditional tripod mounted instruments such as total stations it becomes apparent that additional modeling, above and beyond this formula may be required. Of particular interest is the possible non-orthogonality between the plane containing the horizontal angle encoder and the vertical axis. This would create a sinusoidal error with period of 180° for the horizontal angle measurements [7]. In order to account for this possibility the encoder angle measurements are supplemented to include the possibility of these terms.
Δ ε = h x sin ( 2 ε ) + h y cos ( 2 ε )
It should be noted that it is assumed that the 64 lasers in the Velodyne scanner are rigidly attached to the same assembly, and therefore the corrections computed by Equation (2) are common for all of the lasers. The inclusion of these errors therefore only adds an additional two unknowns to the overall model for the scanner.

3. Least Squares Adjustment Functional Model

The adjustment used for the Velodyne scanner is a plane-based calibration approach. Details of this approach for airborne scanner boresight determination or static scanner calibration are available in the literature (e.g., [8,9]), so a detailed development of the model is not repeated here. The observational model for the planar approach is based upon conditioning the individual LiDAR points to lie on a global planar surface. The functional model for this conditioning is given as:
f ( j , k , l ) = g l , [ r 1 ] = 0
where g l = [ g 1 g 2 g 3 g 4 ] T are the unknowns of a plane l on which the LiDAR points are conditioned, and r is the vector of globally referenced LiDAR points. For a static calibration, with data collected from k locations, the jth point can be calculated in a global coordinate frame via a rigid body transformation of the form:
r = R ( w , p , k ) k l jk + t k
where R ( w , p , k ) k and t k are the rotational transformation matrix and translation vector between the kth scanner space and the global coordinate frame respectively, and l jk is the scanner space coordinates of point j, given by Equation (1). For the static calibration procedure, the rotation and translation vectors for each of the scanner spaces k are normally unknown, and are therefore included in the adjustment as additional unknowns.
The optimal solution to the least squares adjustment for the functional model described in above can be given by the standard Gauss-Helmert adjustment model [10]. For details on the implementation of the Gauss-Helmert adjustment model for planar constraints, the reader is referred to [9], and to [5] for a more detailed discussion of some of the aspects of the functional model utilized herein for the static Velodyne calibration.

4. Static Data Collection

In a period of six months at the beginning of 2010, Terrapoint had access to two Velodyne HDL‑64E S2 scanners, one which was loaned to Terrapoint for evaluation, and the second which was purchased to be integrated into a mobile scanning platform for a third party client. Access to two scanners provided Terrapoint the unique opportunity to not only verify the temporal stability of the Velodyne scanner but also to verify that the conclusions were similar for more than one scanner.
Several datasets for each scanner were collected for the purposes of static calibration and for temporal stability assessment. Herein we will focus on four datasets, two for each of the laser scanners. For consistency, these datasets will be referred to as Laser 1–Set 1, Laser 1–Set 2, Laser 2–Set 1, and Laser 2–Set 2.
All four of the datasets were collected in the same calibration area. For reference, this was also the same scene used for calibration in [5]. Sixteen individual stations (or set-ups) of scan data were collected for each datasets. The scanner was placed at one of three scan locations, and was inclined at an angle of 0°, 45°, or 90°. The azimuth of the scanner for the each of the collections was also varied. A schematic of the scanned scene, along with a representative photo of one of the buildings is given in Figure 2. The scan locations, inclinations and azimuth for each of the 16 set-ups are given in Table 1. Note that the scan location numbers refer to the blue numbered circles in Figure 2(a).
Figure 2. Experimental Data Collection Layout. (a) Scan locations in blue, buildings in red, and fence in green, and (b) photo of the building in Northwest Quadrant (taken at Scan Location 1).
Figure 2. Experimental Data Collection Layout. (a) Scan locations in blue, buildings in red, and fence in green, and (b) photo of the building in Northwest Quadrant (taken at Scan Location 1).
Remotesensing 03 00539 g002
Table 1. Position and Orientation of 16 Scans in Each of the Four Datasets.
Table 1. Position and Orientation of 16 Scans in Each of the Four Datasets.
Set-Up #Scan LocationInclination (°)Azimuth (°)
11090
210270
3200
420180
5300
630180
714545
8145135
9145225
10145315
112450
12345180
1319045
14190135
15190225
16190315
For each dataset, between 120 and 150 planar surfaces were extracted from all sixteen set-ups. The planar surfaces were chosen to provide an even distribution of points from each set-up, at varying planar inclination angles, and from each laser in the Velodyne sensor array. The analysis in [5] had shown that planar points with higher incidence angles (i.e., >70°) exhibited larger residuals, consistent with studies of other instruments (e.g., [7]). However, even though these points showed higher residuals, their inclusion in the adjustments was not found to significantly influence the final estimated calibration parameters for the scanner. Therefore, for the analysis presented below, observations at all incidence angles were included.

5. Static Parameter Observability

5.1. Horizontal and Vertical Offsets

In the preliminary analysis of the scanner [5] it was noted that a high degree of correlation existed between the horizontal rotation correction, and the horizontal offset error, and the vertical rotation correction and the vertical offset error. At that time it was postulated that the high correlation could be mitigated by including observations with the scanner inclined at a larger angle. (In the original testing the incline was a maximum of 30°). Therefore, the new observation sets were collected with the scanner inclined at 0°, 45° and 90° (as previously detailed). A comparison of correlation coefficients is given in Table 2(a,b) below.
Table 2(a,b) shows that even with the additional inclined planes the cross correlation coefficients between the horizontal and vertical angle and offset parameters are still quite high. The additional set‑ups only marginally decoupled these components. In addition, if we examine the magnitude of the new corrections, they physically appear to not make sense. The overall corrections of the horizontal offset are up to 8 cm. However, the laser assembly itself only has a radius of approximately 8 cm. This would suggest that this high correlation makes these parameters unobservable, even with the increased inclination observations.
Table 2. (a) Correlation Coefficients from the Original Analysis [5]; (b) Correlation Coefficients with Inclined Observations.
Table 2. (a) Correlation Coefficients from the Original Analysis [5]; (b) Correlation Coefficients with Inclined Observations.
(a)
Correlation Coefficients
Y Z wp k δβDioHioVios
X 0.1130.0640.0720.1530.190.0120.0450.0180.0110.0180.029
Y 0.1140.0710.0830.2270.0230.0150.0220.010.0220.145
Z 0.4590.1950.0420.0380.0130.0390.0140.0350.019
w 0.1570.1880.0980.0170.0250.0210.0940.021
p 0.170.0780.0210.0190.0210.0760.021
k 0.0220.0680.0230.0240.0180.021
δ 0.1270.4910.0950.9090.454
β 0.1320.8790.1110.193
Dio 0.1120.5930.754
Hio 0.0910.154
Vio 0.493
(b)
Correlation Coefficients
YZwpkδβDioHioVios
X0.1250.1230.1050.2530.2810.0310.1740.0290.0180.040.078
Y 0.1010.2190.1810.2490.0430.0720.0620.0120.0410.272
Z 0.4470.1600.1110.1080.0240.0670.0160.1410.050
w 0.1230.4650.1220.0670.0600.0210.1310.067
p 0.2090.0540.1500.0200.0180.0490.065
k 0.0370.0830.0230.0240.0350.038
δ 0.1060.3070.1060.8980.282
β 0.1360.7870.0880.246
Dio 0.1510.4130.555
Hio 0.0990.172
Vio 0.295
In order to determine how we can further decouple these observations, we can examine the first derivatives of (3) w.r.t. each of the highly correlated components. The derivative of (3) with respect to the vertical offset is given as:
f ( j , k , l ) V o i = g 1 m 13 + g 2 m 23 + g 3 m 33
where m x y , refers to the value in the x row and y column of the rotation matrix R ( w , p , k ) . Similarly, the derivative of (3) with respect to the vertical angle is given by:
f ( j , k , l ) δ i = g 1 ( s i *R i + D o i ) [ sin ( δ i ) ( m 11 + m 12 ) + cos ( δ i ) m 13 ] + g 2 ( s i *R i + D o i ) [ sin ( δ i ) ( m 21 + m 22 ) + cos ( δ i ) m 23 ] + g 3 ( s i *R i + D o i ) [ sin ( δ i ) ( m 31 + m 32 ) + cos ( δ i ) m 33 ]
Here we have simplified the formula by considering the encoder angle as zero, and neglected the horizontal rotation corrections (which are small, i.e., <5°). At first glance, the derivatives in (5) and (6) do not appear similar, however if we consider that for the Velodyne scanner, the vertical angle δi is < 30°, then the derivative in (6) will be dominated by the cosine terms (especially for the lasers with small vertical angles), which after rearranging is:
f ( j , k , l ) δ i cos ( δ i ) ( s i *R i + D o i ) [ g 1 m 13 + g 2 m 23 + g 3 m 33 ]
The term in square brackets in (7) is identical to the derivative w.r.t. vertical offset given in (5), and shows the strong correlation between the two unknowns. This also shows that the observations at increased inclination angle will only have a marginal influence in decorrelating the vertical angle and vertical offset, and then only for the lasers with a larger vertical angle. A graphical representation of the correlation is shown in Figure 3, where the first derivatives of the vertical offset and vertical angle are plotted for each point in the Laser 1–Set 1 adjustment. Please note that the vertical offset derivatives have been scaled by the raw distance to better directly compare the similarities in trends. The points observed with the laser at 0°, 45° and 90° inclination are also indicated in the figure.
Figure 3. Comparison of First Derivatives For Vertical Offset (Red) and Vertical Angle (Blue) Unknowns, Laser 1–Set 1.
Figure 3. Comparison of First Derivatives For Vertical Offset (Red) and Vertical Angle (Blue) Unknowns, Laser 1–Set 1.
Remotesensing 03 00539 g003
Figure 3 clearly shows that for all observations there is a significant correspondence between the vertical angle and offset unknowns. This correspondence is only marginally reduced for the observations collected with the scanner inclined at 45° and 90°. Figure 4 gives a histogram of the range observations for Laser 1–Set 1. It clearly shows that a favorable distribution of ranges was unable to decouple the vertical offset and vertical angle.
Figure 4. Histogram of Raw Range Measurements, Laser 1–Set 1.
Figure 4. Histogram of Raw Range Measurements, Laser 1–Set 1.
Remotesensing 03 00539 g004
A similar examination of the derivatives for the horizontal angle and horizontal offset parameters can also be undertaken. First, the derivative of the functional in Equation (3) w.r.t. the horizontal angle unknown is given as:
f ( j , k , l ) β i = ( s i *R i + D o i ) cos ( δ i ) [ ( g 1 m 11 + g 2 m 21 + g 3 m 31 ) ( sin ( ε ) sin ( β i ) cos ( ε ) cos ( β i ) ) + ( g 1 m 12 + g 2 m 22 + g 3 m 32 ) ( cos ( ε ) sin ( β i ) + sin ( ε ) cos ( β i ) ) ]
Note that in Equation (8) terms that are multiplied by H o i have been neglected since they are insignificant compared to terms multiplied by the measured range, as the magnitude of H o i is nominally 2.6 cm. The derivative of the functional in Equation (3) with respect to the horizontal offset is then given by:
f ( j , k , l ) H o i = [ ( g 1 m 11 + g 2 m 21 + g 3 m 31 ) ( sin ( ε ) sin ( β i ) cos ( ε ) cos ( β i ) ) + ( g 1 m 12 + g 2 m 22 + g 3 m 32 ) ( cos ( ε ) sin ( β i ) + sin ( ε ) cos ( β i ) ) ]
The only difference between Equations (8) and (9) is that the former is multiplied by the range to target and the vertical angle (which is constant for each laser). Again, the very similar structure of the derivatives illustrates why even with additional observations were unable to significantly decouple the unknowns. At present it would appear that the calibration process is unable to physically observe these parameters. However, the physical location of each laser emitter/receiver pair is precisely located within the machined portion of the laser assembly. These locations are known with a level of accuracy from the CAD drawings that is at least an order of magnitude better than the ranging accuracy of the instrument. Therefore, it seems reasonable to hold the factory values for the horizontal and vertical offsets as fixed without compromising the overall calibration parameter determination of the instrument. This assumption will be justified later in the manuscript when it is noted that the individual laser range residuals are at or near the manufacturer specifications when the offset parameters are held fixed.

5.2. Global Non-Orthogonality

For each of the datasets acquired, the horizontal non-orthogonality parameters (hx, hy) were estimated. The estimated values for each dataset, along with the estimated accuracies of the solutions are given in Table 3.
Table 3. Horizontal Encoder Non-Orthogonality Parameters for the Four Acquired Datasets.
Table 3. Horizontal Encoder Non-Orthogonality Parameters for the Four Acquired Datasets.
hx/σ (°)hy/σ (°)
Laser 1–Set 1−0.0259/0.00090.0244/0.0013
Laser 1–Set 2−0.0196/0.00090.0029/0.0011
Laser 2–Set 1−0.0271/0.00100.0137/0.0015
Laser 2–Set 2−0.0351/0.00110.0142/0.0015
If we consider that the quantization error of the horizontal encoder angle measurements is 0.024°, then the hy estimates, with the exception of Laser 1–Set 1, do not appear to be significant since they are consistently below this level. The hx estimate is marginally significant, as the estimated value in all four cases hovers near the quantization level. The estimated standard deviations of the non‑orthogonality parameters are in all cases at least an order of magnitude smaller than the estimated parameter value which indicates a high level of observability and overall confidence in the adjusted value. However, it should be noted that the introduction of the hx and /or hy component does not appear to have a measurable impact on reducing either the range and angle measurement residuals or the overall planar misclosure vectors. Given that the parameter significance appears to be borderline, and that the estimated standard deviations are consistently low, we have decided to include these parameters for subsequent HDL-64E S2 calibrations.

6. Temporal Stability of the Scanner

To examine the temporal stability of the scanners, two separate calibration datasets were collected with each scanner, separated by a short period of time and a complete cool-down and restart of the lasers. Figure 5 shows the difference in calibration parameters between Laser 1–Set 1, and Laser 1–Set 2, and Figure 6 shows the differences between Laser 2–Set 1 and Laser 2–Set 2. Note that in Figure 5 and Figure 6 the scale factor difference has been multiplied by 50 to give an indication of the relative size of the scale differences. Fifty was chosen because it represents the longest raw ranges observed in the calibration datasets.
Figure 5. Temporal Calibration Differences between Observation Sets for Laser 1.
Figure 5. Temporal Calibration Differences between Observation Sets for Laser 1.
Remotesensing 03 00539 g005
Figure 6. Temporal Calibration Differences Between Observations Sets for Laser 2.
Figure 6. Temporal Calibration Differences Between Observations Sets for Laser 2.
Remotesensing 03 00539 g006
Overall, the temporal stability of the calibration shows a disagreement that is slightly higher than expected. Given that the stated range accuracy of the lasers is 2 cm (1σ), and the quantization noise on the encoder is 0.024°, we would expect agreement between epochs to be nearer to 0.02 (° or m) for all lasers.
A closer examination of the graphs shows that for all lasers, the agreement between the horizontal encoder offset is within the quantization noise of the encoder, which indicates a strong solution. However, the range offset, scale factor and vertical angle measurements all show disagreements up to the level of 4 to 5 cm in some cases (for the vertical angle, consider that 0.05° (= 4 cm at 50 m range). The differences in these three estimated calibration parameters will of course be largely determined by instability in the ranging accuracy of the lasers. Therefore, in an attempt to explain these errors the individual laser range measurements and their long term stability are examined.
Figure 7 plots the RMSE residuals for each laser individually, before and after adjustment for Laser 2–Set 1. The figure clearly shows that there is an overall reduction in the RMSE range residuals for all of the lasers. However, even after adjustment, the residuals vary widely from laser to laser, from a minimum RMSE of 12 mm, to a maximum of 28 mm. For the purposes of the least squares adjustment however, all lasers were weighted equally. It is therefore possible that some of the higher than expected variability between epochs may be a result of the higher than expected residual noise in some of the lasers, although it is doubtful that this could be the cause of the majority of the variation in Figure 5 and Figure 6. However, Figure 7 is an important by-product of the adjustment process. It allows an examination of each laser on an individual basis. For post-acquisition processing, the results in the figure could be used as a relative weighting scheme, or for high accuracy applications, the lasers with the worst performance (i.e., 1, 5, 32, 34, and 44) could be eliminated from the final point cloud.
Figure 7. RMSE of Range Residuals for Each Laser, Before and After Adjustment, Laser 2–Set 1.
Figure 7. RMSE of Range Residuals for Each Laser, Before and After Adjustment, Laser 2–Set 1.
Remotesensing 03 00539 g007
Based on the above comparisons, it is evident that there may be some longer term variations or problems with the accuracy of the individual range measurements. Therefore, in an attempt to discover the root cause of the problem, longer term static scans were collected from the scanner. The unit was set up to scan a wall at a distance of approximately 2.5 m. Ranges were sampled approximately every minute for a period of 18 hours. The initial dataset is shown in Figure 8. Note that in the figure, the deviations from the average range taken over the entire dataset (for each individual laser) are plotted. Each laser is plotted individually, 63 lasers as black crosses, and one laser as green squares to show the representative deviation for a single laser. The red line in the Figure highlights the long-term average trend for all lasers.
In examining Figure 8 it is apparent that there is not a significant long-term range drift in the instrument. The long term variability appears bounded by approximately ±2 cm, which is still within the ranging accuracy of the individual lasers. However, the one area of concern is the initial slope of the range biases on the left hand side of the graph, which shows a change in the mean bias of approximately 3 cm over a period of 3 hours. All of the datasets collected with the Velodyne for the purposes of this analysis were collected with 3 hours of turning the laser on. This would indicate that initially there may be some “warm-up” changes in the behavior of the sensor which may partially explain the higher-than-average differences in the temporal calibration parameters displayed earlier. Repeated static tests of the scanners have confirmed the behavior displayed in Figure 8. Theoretically, this problem could be addressed by first allowing the scanner a warm up period. However, given that the period of warm up appears to be almost 3 hours, this would not be practical for either (a) calibration of the instrument or (b) using of the instrument on a mobile scanning platform.
Figure 8. Long Term Range Drift—Velodyne HDL-64E S2.
Figure 8. Long Term Range Drift—Velodyne HDL-64E S2.
Remotesensing 03 00539 g008

8. Final Calibrated Residuals

As a final analysis of the temporally collected datasets, average calibration values were determined for both Lasers 1 and 2 from the adjusted calibration values determined with their respective Set 1 and Set 2 solutions. The averaged calibration sets were then used to correct the original observations to determine the overall planar misclosures for each of the four collected datasets. The results are presented in Table 4, which shows for each of the four observation sets the global planar misclosure statistics for (a) the original Velodyne factory calibration values (Factory Calibration), (b) the derived calibration values from that observation set only (Set Calibration), and (c) an averaged calibration values using an average of both sets from each laser (Averaged Calibration). Note that for all statistics, planar misclosure outliers larger than 4σ, for the final adjusted points have been removed from the calculations.
The results in Table 4 show that the averaged calibration parameters for each laser give a marked performance improvement over the factory calibration parameters for all four datasets. Although the average calibration does not perform as well as the set calibration determined individually for each observation session, the improvement over the factory calibration is consistently above 25%. This improvement is significant for high accuracy mobile scanning applications. Table 4 shows that with temporally averaged calibration parameters a 3D RMSE accuracy of approximately 2.0 cm can be obtained with the Velodyne HDL 64E S2. Of course, this performance could theoretically be significantly improved if the laser were calibrated on a mission to mission basis. While possible, it is likely not practical to perform this type of rigorous internal calibration adjustment for the laser for all datasets collected.
Table 4. Planar Misclosures for Each Observation Set with Factory, Set and Averaged Calibration Parameters.
Table 4. Planar Misclosures for Each Observation Set with Factory, Set and Averaged Calibration Parameters.
Factory CalibrationSet CalibrationAveraged Calibration
Min (m)Max (m)RMSE (m)Min (m)Max (m)RMSE (m)Min (m)Max (m)RMSE (m)
Laser 1–Set 1−0.1700.1230.025−0.0610.0600.015−0.0760.0750.019
Laser 1–Set 2−0.1350.1810.029−0.0510.0510.013−0.0760.0740.019
Laser 2–Set 1−0.1840.1700.026−0.0520.0520.013−0.0790.0810.020
Laser 2–Set 2−0.1600.2240.028−0.0480.0480.012−0.0800.0810.021

9. Summary and Future Work

The analysis contained herein is built upon the initial static calibration analysis of the HDL 64E S2 which was reported in [5]. First, the mathematical model of the Velodyne scanner was examined in more detail. Global misalignment terms, which represent deviations of the horizontal encoder from the vertical axis of scanning, were included. It was found that for the instruments examined in this study the misalignment is marginally significant, but should be monitored for additional scanner calibration computations before general conclusion about their inclusion in the mathematical model can be drawn. The horizontal and vertical offset parameters were shown to be very highly correlated with the horizontal and vertical angular offsets for the scanner, and they do not appear observable in any contrived static calibration observation scenario. It was therefore recommended that the manufacturer values for these parameters be treated as fixed.
Finally, the temporal stability of the scanner was examined by collecting observations with two separate HDL-64E S2 laser scanners, each with two observational data sets collected at two different epochs. For both scanners, the temporal agreement of the horizontal angle offset was at or near the quantization level of the encoder, however the vertical angle offset, distance offset and distance scale factor showed temporal differences that were larger than expected. Currently, we believe this is due to long term variability in the range measurements from the individual laser scanners, especially during their initial switch-on warm up period. However, despite this, an averaged (temporally) calibration set still showed a 25% or greater improvement in overall 3D planar misclosure over the factory determined calibration parameters. The final 3D accuracy of the observed point clouds was estimated to be 2.0 cm.
There are still some small additional temporal variations present in the point clouds whose root cause has yet to be identified, however the improvement in overall accuracy by removing these variations is not expected to be significant (perhaps 5 mm RMSE). As a final step, the authors plan to examine kinematic data collected with the Velodyne scanner and a navigation grade GNSS/INS unit to determine overall accuracy of the scanner for integrated high accuracy mobile mapping applications.

Acknowledgements

Velodyne LiDAR is acknowledged for providing the HDL-64E S2 scanners to Terrapoint for analysis for suitability of inclusion in their mobile scanning system solutions. Jerry Dueitt, Ian Collins and Steven Jacobs of Terrapoint are also thanked for their assistance in collecting the raw data for the above analysis.

References and Notes

  1. Schwarz, B. Mapping the world in 3D. Nat. Photonics 2010, 4, 429–430. [Google Scholar] [CrossRef]
  2. Dunbar, M.; Neuman, M. Mobile Mapping and Data Collection. GEO: International, April 2008; 40–42. [Google Scholar]
  3. Markoff, J. Google cars drive themselves, in traffic. The New York Times, 10 October 2010; A1. [Google Scholar]
  4. Topcon Announces IP-S2 HD Mapping System. Available online: http://www.topconpositioning.com/news-events/single/item/topcon-announces-ip-s2-hd-mapping-system/ (accessed on 22 January 2011).
  5. Glennie, C.; Lichti, D.D. Static calibration and analysis of the Velodyne HDL-64E S2 for high accuracy mobile scanning. Remote Sens. 2010, 2, 1610–1624. [Google Scholar] [CrossRef]
  6. High Definition LiDAR; Datasheet for Velodyne HDL-64E S2; Velodyne: Morgan Hill, CA, USA; Available online: http://www.velodyne.com/lidar/products/brochure/HDL64E%20S2%20datasheet_2010_lowres.pdf (accessed 22 January 2010).
  7. Lichti, D. Error modeling, calibration and analysis of an AM-CW terrestrial laser scanner system. ISPRS J. Photogramm. Remote Sens. 2007, 61, 307–324. [Google Scholar] [CrossRef]
  8. Filin, S. Recovery of systematic biases in laser altimetry data using natural surfaces. Photogramm. Eng. Remote Sensing 2003, 69, 1235–1242. [Google Scholar] [CrossRef]
  9. Skaloud, J.; Lichti, D. Rigorous approach to bore-sight self-calibration in airborne laser scanning. ISPRS J. Photogramm. Remote Sens. 2006, 61, 47–59. [Google Scholar] [CrossRef]
  10. Förstner, W.; Wrobel, B. Mathematical concepts in photogrammetry. In Manual of Photogrammetry, 5th ed.; McGlone, J.C., Mikhail, E.M., Bethel, J., Mullen, R., Eds.; American Society of Photogrammetry and Remote Sensing: Bethesda, MD, USA, 2004; pp. 15–180. [Google Scholar]

Share and Cite

MDPI and ACS Style

Glennie, C.; Lichti, D.D. Temporal Stability of the Velodyne HDL-64E S2 Scanner for High Accuracy Scanning Applications. Remote Sens. 2011, 3, 539-553. https://doi.org/10.3390/rs3030539

AMA Style

Glennie C, Lichti DD. Temporal Stability of the Velodyne HDL-64E S2 Scanner for High Accuracy Scanning Applications. Remote Sensing. 2011; 3(3):539-553. https://doi.org/10.3390/rs3030539

Chicago/Turabian Style

Glennie, Craig, and Derek D. Lichti. 2011. "Temporal Stability of the Velodyne HDL-64E S2 Scanner for High Accuracy Scanning Applications" Remote Sensing 3, no. 3: 539-553. https://doi.org/10.3390/rs3030539

Article Metrics

Back to TopTop