Next Article in Journal
Application of Passive Sampling to Characterise the Fish Exometabolome
Next Article in Special Issue
Impact of Exercise and Aging on Rat Urine and Blood Metabolome. An LC-MS Based Metabolomics Longitudinal Study
Previous Article in Journal
Urine and Serum Metabolomics Analyses May Distinguish between Stages of Renal Cell Carcinoma
Previous Article in Special Issue
Effects of Different Exercise Modes on the Urinary Metabolic Fingerprint of Men with and without Metabolic Syndrome
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

QSRR Modeling for Metabolite Standards Analyzed by Two Different Chromatographic Columns Using Multiple Linear Regression

by
Chrysostomi Zisi
1,*,
Ioannis Sampsonidis
2,
Stella Fasoula
1,
Konstantinos Papachristos
1,
Michael Witting
3,
Helen G. Gika
4,
Panagiotis Nikitas
1 and
Adriani Pappa-Louisi
1
1
Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
2
Infrastructure and Environment Research Division, School of Engineering, University of Glasgow, Rankine Building, Oakfield Avenue, G12 8LT Glasgow, United Kingdom
3
Helmholtz Zentrum München, Research Unit Analytical BioGeoChemistry, Ingolstaedter Landstrasse 1, D-85764 Neuherberg, Germany
4
Department of Medicine, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
*
Author to whom correspondence should be addressed.
Metabolites 2017, 7(1), 7; https://doi.org/10.3390/metabo7010007
Submission received: 21 December 2016 / Accepted: 5 February 2017 / Published: 9 February 2017
(This article belongs to the Special Issue Metabolomics 2016)

Abstract

:
Modified quantitative structure retention relationships (QSRRs) are proposed and applied to describe two retention data sets: A set of 94 metabolites studied by a hydrophilic interaction chromatography system under organic content gradient conditions and a set of tryptophan and its major metabolites analyzed by a reversed-phase chromatographic system under isocratic as well as pH and/or simultaneous pH and organic content gradient conditions. According to the proposed modification, an additional descriptor is added to a conventional QSRR expression, which is the analyte retention time, tR(R), measured under the same elution conditions, but in a second chromatographic column considered as a reference one. The 94 metabolites were studied on an Amide column using a Bare Silica column as a reference. For the second dataset, a Kinetex EVO C18 and a Gemini-NX column were used, where each of them was served as a reference column of the other. We found in all cases a significant improvement of the performance of the QSRR models when the descriptor tR(R) was considered.

1. Introduction

In metabolomics, the identification of metabolites in biological samples is of a great importance. Liquid chromatography couple to mass spectrometry (LC-MS) is widely used in metabolomics. However, even if accurate measurements of mass-over-charge ratio, m/z, have been taken, only the molecular type of the metabolite can be determined. That happens because there are many analytes that have the same molecular weight. For this reason, the use of retention data is of great help for the identification of metabolites in metabolomics and in this direction, quantitative structure-retention relationship (QSRR) models are used more frequently [1]. QSRR models relate chromatographic retention data with molecular descriptors (MDs)—i.e., theoretical or experimental properties of molecules—in order to predict the retention time and to annotate the metabolites.
The more frequently used MDs in QSRR models are physicochemical descriptors because they are strongly correlated with solute retention [2]. So, QSRR models can be developed either from a small set of a priori chosen MDs based on solute physicochemical properties that are compiled from the literature or from a large set of calculated MDs by using appropriate software [2,3]. Besides the MDs recorded in the literature, experimental values of the descriptors can be applied in the QSRR models [4]. Moreover, different modeling methodologies, such as multiple linear regression (MLR), partial least squares (PLS), generic algorithms (GA), and artificial neural network (ANN), can be applied in order to develop a QSRR model [2,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20]. Additionally, the QSRR models can be used in combination with the principal component analysis (PCA), when a large number of columns have been used, and the column classification can be achieved [21]. In literature, three LC-MS methods based on a reversed phase (RP), a hydrophilic interaction chromatography (HILIC), and a pentafluorophenylpropyl (PFPP) stationary phase have been used for metabolite identification via QSRR models [6]. It is also worth mentioning that the pH-gradient conditions are helpful in peptide separation [22,23] and in polar solution separation in general.
In the present study, we propose a modification of conventional QSRR models by adding an extra term, which is the metabolite retention time measured under the same experimental conditions in a second (reference) chromatographic column. That is:
tR(Α) = a1MD1 + a2MD2 + … + anMDn + btR(R)
where tR(A), tR(R) are the metabolite retention times measured under the same conditions in the chromatographic column under study (A) and in the reference column (R), MD1, …, MDn are either a priori chosen MDs or the statistically significant molecular descriptors among a variety of theoretical MDs and a1, a2, ..., an, and b are adjustable parameters calculated by using the multiple linear regression (MLR) method.
Note that in a QSRR study on gas chromatographic data, a similar modification was proposed by Kaliszan and Hōltje, where retention data obtained on two phases of different polarities were used for the determination of the stationary phase polarizability coefficient [24]. Note also that in the QSRR models developed in the present study, the dependent variable—i.e., the retention parameter—is expressed in terms of retention time instead of logarithm of retention factor, logk, following the practice adopted in gradient elution mode [2,4,8,21,22].
To test the performance of the proposed modification, two data sets have been adopted. The first dataset consisted of 94 metabolite standards and the second one consisted of eight solutes, which were tryptophan and its major metabolites.

2. Materials and Methods

2.1. Experimental

The first dataset of the 94 metabolites was analyzed by a HILIC system. The LC–MS analysis was used and it was performed on a Waters ACQUITY TQD System (Waters Corporation, Milford, MA, USA). The flow rate was fixed at 400 μL/min and the injection volume at 10 μL. Column temperature was maintained at 50 °C. Both positive and negative ionization were used depending on the analyte (polarity switching). In the source the capillary voltage was set to 2.5 kV in negative ionization mode or 3.5 kV in positive ionization mode. Block and desolvation temperatures were set at 150 and 350 °C, respectively. Desolvation gas flow rate was 650 L/h and no cone gas was applied. The data analysis was performed with Waters MassLynx version 4.1 (SCN 882) and TargetLynx.
The 94 metabolite standards used as analytes, classified in seven chemical groups (sugars, aminoacids, acids, nucleonic bases-nucleosides, vitamins, alkaloids, and amides), are presented in Table S1 as Supplementary Materials. Stock solutions of the compounds were prepared in concentrations of 1000 μg/mL in methanol:water 1:1 (v/v).
The LC analysis was performed in two HILIC columns: (Α) a BEH HILIC Amide Waters Acquity (1.7 μm, 2.1 × 150 mm) and (Β) Bare Silica Waters BEH HILIC. The mobile phases used were aqueous buffer HCOONH4—HCOOH with pH = 3 modified by 95% acetonitrile (eluent A) or 60% acetonitrile (eluent B). The applied gradient program is presented in Table S2 as Supplementary Materials.
The second dataset analyzed by an RP-chromatographic system consisted of a Shimadzu LC-20AD pump, a Shimadzu DGU-20A3 degasser, a model 7125 syringe loading sample injector matted with a 5 mL loop, a Kinetex EVO C18 (5 μm 150 × 4.6 mm), and a Gemini-NX (5 μm 150 × 4.6 mm) column thermostatted at 25 °C by a CTO-10AS Shimadzu column oven and a Shimadzu UV-visible spectrophotometric detector (Model SPD-20A) working at 254 nm. The analytes were tryptophan and its major metabolites. In more details, the solutes behave in the mobile phase pH range tested as: ampholytes (anthranilic acid, ANA, 3-Hydroxyanthranilic acid, HANA, tryptophan, TRP, and l-kynurenine, KYN), diprotic acids (5-hydroxytryptophan, HTRP, kynurenic acid, KYNA, and 5-hydroxyindole acetic acid, HIAA), and monoprotic bases (5-hydroxytryptamine, HT). These eight solutes were studied under isocratic as well as pH and/or simultaneous pH and organic content gradient conditions. Their retention data and the experimental conditions are presented in Tables S3 and S4, respectively, in Supplementary Materials.

2.2. Molecular Descriptors and Statistical Procedures

In order to develop QSRR models that can describe the 94 standard metabolites, 309 molecular descriptors (MDs) were calculated by using RDKit toolkit and RCDK software. No geometry optimization was performed before computation of descriptors. These MDs are given in Table S5 as Supplementary Materials. For the second dataset, we used three a priori chosen MDs: pKa1, pKa2, and logP. The definition of the selected MDs is presented in Table S6 as Supplementary Materials.
Multiple linear regression (MLR) was applied to determine QSRR models by means of the linear procedure in IBM SPSS Statistics 21 using two options: The Enter option was used in order to include certain MDs in the model and the Forward option to include only statistically significant MDs. That is, at each step of the Forward option, the variable, which is not yet in the equation, with the smallest p-value is entered provided that this value is smaller than 0.05. The procedure stops when there are no variables that meet this criterion.

3. Data Analysis and Discussion

3.1. QSRR Models for 94 Metabolites Standards

The application of MLR with the Forward option to the first dataset of 94 standard metabolites initially using 309 theoretical MDs resulted in two six-parameter QSRR models that can describe the retention data in each chromatographic column (Amide and Bare Silica). That is:
tR = a1MD1 + a2MD2 + … + anMDn
where n = 6 and tR is the metabolites retention time measured under gradient conditions in a certain chromatographic column. Table 1 presents these statistically significant MDs, the corresponding adjustable parameters, their standard deviations, the average and maximum absolute difference between experimental and calculated retention time from Equation (2), and the standard error of the estimate (SEE) for the Amide and Bare Silica columns.
From the results presented in this table, we conclude that the six-parameter QSRR models describe the retention data on both columns equally satisfactorily. To examine if this description can be further improved by the proposed modification of QSRR models, the retention time of the metabolite standards from Bare Silica column was used as an extra independent parameter (experimental descriptor) in classic QSRR model of Equation (2). In this model the MDs used were those determined in the previous step, i.e., tpsaEfficiency, XLogP, nBase, MDEC.33, nR, and C2SP3. The adjustable parameters of this model along with its performance are given in Table 2. It is seen that when the metabolites retention time in a second (reference) chromatographic column is used in a QSRR model as an extra independent parameter, the fitting performance is improved considerably, since all quantities related to model performance—i.e., average absolute difference of experimental and calculated tR, maximum absolute difference of experimental and calculated tR, and the standard error of the estimate, SEE—are improved. Note that the standard error of the estimate is usually used as a measure of the relative quality of statistical models for a given set of data. That is, SEE estimates the quality of each model relative to each of the other models studied under the same conditions and the best model is that with the minimum SEE value. Therefore, based on this criterion, the proposed modification yields a better QSRR model.

3.2. QSRR Models for Each Chemical Group of 94 Metabolites Standards

The majority of the 94 metabolite standards was classified in four groups of chemically related compounds, which are 13 sugars, 33 amino acids, 21 acids, and 14 nucleonic bases-nucleosides, see Table S1 of the Supplementary Materials. For each chemical group the procedure described in the previous section was applied and two QSRR models, without and with the term btR(R), were developed. The results are presented in Table 3 and show again that the proposed modification considerably improves the model performance. As expected, the QSRR models developed for each chemical group describe the retention of metabolites better than a QSRR model developed for all the metabolites.

3.3. QSRR Models for Tryptophan and Its Major Metabolites

The QSRR models described in the previous sections concern organic content gradient conditions on HILIC columns. In order to examine whether the proposed modification of the QSRR models works also on reversed-phase columns under isocratic as well as pH and/or simultaneous pH and organic content gradient conditions, we analyzed the retention data of tryptophan and its major metabolites shown in Table S3. The study was performed under four elution conditions in two chomatographic columns (Table S4 as Supplementary Materials).
To analyze these data, three a priori chosen MDs—derived from chemicalize.org—were used. These MDs were pKa1, pKa2, and logP. For the application of the proposed modification of the QSRR models, each of the two chromatographic columns was used as a reference column of the other column.
The QSRR models with and without the proposed modification are shown in Table 4 and Table 5, respectively, where we again observe the better performance of the models under the proposed modification. Note that the different elution order of the analytes on the two different columns used does not affect the performance of the proposed models.

4. Conclusions

To sum up the above results, it was found that the proposed modification of conventional QSRR models, which introduces the retention on a reference chromatographic column as an extra descriptor, significantly improves the performance of the developed QSRR models in comparison to classic ones. Note that in the proposed QSRR models, the term tR(R) is always statistically significant. Consequently, these models could be used with confidence in the identification of metabolites by predicting their retention time on a liquid chromatography column.

Supplementary Materials

The following are available online at www.mdpi.com/2218-1989/7/1/7/s1, Table S1. 94 metabolites standards used in the first dataset, classified in 7 chemical groups (sugars, aminoacids, acids, nucleonic bases-nucleosides, amides, vitamins and alkaloids) and their retention data obtained under the same elution conditions on two different chromatographic columns; Table S2. Gradient program applied for the LC-MS analysis of 94 standard metabolites; Table S3. Solutes of the second dataset (tryptophan and its major metabolites) and their retention data obtained under four elution conditions on two different chromatographic columns; Table S4. Elution conditions applied for the HPLC analysis of tryptophan and its metabolites; Table S5. 309 MDs calculated from RDKit toolkit and RCDK software; Table S6. The descriptor class and the definition of the MDs used in all proposed models.

Acknowledgments

Research committee of Aristotle University of Thessaloniki, for a postdoc scholarship “Excellence 2015”.

Author Contributions

Adriani Pappa-Louisi and Helen G. Gika conceived and designed the experiments; Ioannis Sampsonidis and Stella Fasoula performed the experiments; Chrysostomi Zisi and Konstantinos Papachristos analyzed the data; Michael Witting contributed materials/analysis tools; Chrysostomi Zisi and Panagiotis Nikitas wrote the paper. All authors have read and approved the final manuscript.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Randazzo, G.M.; Tonoli, D.; Hambye, S.; Guillarme, D.; Jeanneret, F.; Nurisso, A.; Goracci, L.; Boccard, J.; Rudaz, S. Prediction of retention time in reversed-phase liquid chromatography as a tool for steroid identification. Anal. Chim. Acta 2016, 916, 8–16. [Google Scholar] [CrossRef] [PubMed]
  2. Bodzioch, K.; Durand, A.; Kaliszan, R.; Baczek, T.; Vander Heyden, Y. Advanced QSRR modeling of peptides behavior in RPLC. Talanta 2010, 81, 1711–1718. [Google Scholar] [CrossRef] [PubMed]
  3. Andersson, P.M.; Sjostrom, M.; Wold, S.; Lundstedt, T. Comparison between physicochemical and calculated molecular descreptors. J. Chemom. 2000, 14, 629–642. [Google Scholar] [CrossRef]
  4. Bodzioch, K.; Baczek, T.; Kaliszan, R.; Vander Heyden, Y. The molecular descriptor logSuumAA and its alternatives in QSRR models to predict the retention of peptides. J. Pharm. Biomed. Anal. 2009, 50, 563–569. [Google Scholar] [CrossRef] [PubMed]
  5. Acevedo-Martinez, J.; Escalona-Arranz, J.C.; Villar-Rojas, A.; Tellez-Palmero, F.; Perez-Roses, R.; Gonzales, L.; Carrasco-Velar, R. Quantitative study of the structure-retention index relationship in the imine family. J. Chromatogr. A 2006, 1102, 238–244. [Google Scholar] [CrossRef] [PubMed]
  6. Budah, S.; Olivier, M.F.; Aros-Calt, S.; Oloveira, L.; Fenaille, F.; Tabet, J.C.; Junot, C. Annotation of the human serum metabolome by coupling three liquid chromatography methods to high-resolution mass spectrometry. J. Chromatogr. B 2014, 966, 34–37. [Google Scholar] [CrossRef] [PubMed]
  7. Creek, D.J.; Jankevics, A.; Breitling, R.; Watson, D.G.; Barret, M.P.; Burgess, K.E.V. Toward global metabolomics analysis with hydrophilic interaction liquid chromatography-mass spectrometry: Improved metabolite identification by retention time prediction. Anal. Chem. 2011, 83, 8703–8710. [Google Scholar] [CrossRef] [PubMed]
  8. Gorynski, K.; Bojko, B.; Nowaczyk, A.; Bucinski, A.; Pawliszyn, J.; Kaliszan, R. Quantitative structure–retention relationships models for prediction of high performance liquid chromatography retention time of small molecules: Endogenous metabolites and banned compounds. Anal. Chim. Acta 2013, 797, 13–19. [Google Scholar] [CrossRef] [PubMed]
  9. Cao, M.; Fraser, K.; Huege, J.; Featonby, T.; Rasmussen, S.; Jones, C. Predicting retention time in hydrophilic interaction liquid chromatography mass spectrometry and its use for peak annotation in metabolomics. Metabolomics 2015, 11, 696–706. [Google Scholar] [CrossRef] [PubMed]
  10. Akbar, J.; Iqbal, S.; Batool, F.; Karim, A.; Chan, K.W. Predicting retention times of naturally occurring phenolic compounds in reversed phase liquid chromatography: A quantitative structure-retention relationship (QSRR) approach. Int. J. Mol. Sci. 2012, 13, 15387–15400. [Google Scholar] [CrossRef] [PubMed]
  11. Petric, M.; Crisan, L.; Crisan, M. Synthesis and QSRR study for a series of phosphoramidic acid derivatives. Heteroat. Chem. 2013, 24, 138–145. [Google Scholar] [CrossRef]
  12. Khodadoust, S. A QSRR study of liquid chromatography retention time of pesticides using linear and nonlinear chemometric models. J. Chromatogr. Sep. Tech. 2012, 3, 1–7. [Google Scholar] [CrossRef]
  13. Cirera-Domènech, E.; Estrada-Tejedor, R.; Broto-Puig, F.; Teixidó, J.; Gassiot-Matas, M.; Comellas, L.; Lliberia, J.L.; Méndez, A.; Paz-Estivill, S.; Delgado-Ortiz, M.R. Quantitative structure retention relationships applied to liquid chromatography gradient elution method for the determination of carbonyl-2, 4-dinitrophenylhydrazone compounds. J. Chromatogr. A 2013, 1276, 65–77. [Google Scholar] [CrossRef] [PubMed]
  14. Yan, J.; Cao, D.S.; Guo, F.Q.; Zhang, L.X.; He, M.; Huang, J.H.; Xu, Q.S.; Liang, Y.Z. Comparison of quantitative structure-retention relationship models on four stationary phases with different polarity for a diverse set of flavor compounds. J. Chromatogr. A 2012, 1223, 118–125. [Google Scholar] [CrossRef] [PubMed]
  15. Ghavami, R.; Sepehri, B. Investigation of retention behavior of polychlorinated biphenyl congeners on 18 different HRGC columns using molecular surface average local ionization energy descriptors. J. Chromatogr. A 2012, 1233, 116–125. [Google Scholar] [CrossRef] [PubMed]
  16. Noorizadeh, H.; Farmany, A. Quantitative structure-retention relationship for retention behavior of organic pollutants in textile wastewaters and landfill leachate in LC-APCI-MS. Environ. Sci. Pollut. Res. 2012, 19, 1252–1259. [Google Scholar] [CrossRef] [PubMed]
  17. Noorizadeh, H. Investigation of retention behaviors of essential oils by using QSRR. J. Chin. Chem. Soc. 2010, 57, 982–991. [Google Scholar] [CrossRef]
  18. D’Archivio, A.A.; Ruggieri, F.; Maggi, M.A.; Mazzeo, P. Artificial neural network modelling of retention of pesticides in various octadecylsiloxane-bonded reversed-phase columns and water-acetonitrile mobile phase. Anal. Chim. Acta 2009, 646, 47–61. [Google Scholar] [CrossRef] [PubMed]
  19. D’Archivio, A.A.; Giannito, A.; Maggi, M.A. Cross-column prediction of gas-chromatographic retention of polybrominated diphenyl ethers. J. Chromatogr. A 2013, 1298, 118–131. [Google Scholar] [CrossRef] [PubMed]
  20. D’Archivio, A.A.; Maggi, M.A.; Ruggieri, F. Multiple-column RP-HPLC retention modelling based on solvatochromic or theoretical solute descriptors. J. Sep. Sci. 2010, 33, 155–166. [Google Scholar] [CrossRef] [PubMed]
  21. Michel, M.; Baczek, T.; Studzinska, S.; Bodzioch, K.; Jonsson, T.; Kaliszan, R.; Buszewski, B. Comparative evaluation of high performance liquid chromatography stationary phases used for the separation of peptides in terms of quantitative structure-retention relationship. J. Chromatogr. A 2007, 1175, 49–54. [Google Scholar] [CrossRef] [PubMed]
  22. Baczek, T.; Walijewski, L.; Kaliszan, R. pH gradient reversed-phase liquid chromatography as a fractionation tool for the separation of peptides. Talanta 2008, 75, 76–82. [Google Scholar] [CrossRef] [PubMed]
  23. Wiczling, P.; Markuszewski, M.J.; Kaliszan, M.; Kaliszan, R. pH/organic solvent double-gradient reversed-phase HPLC. Anal. Chem. 2005, 77, 449–458. [Google Scholar] [CrossRef] [PubMed]
  24. Kaliszan, R.; Hōltje, H.-D. Gas chromatographic determination of molecular polarity and quantum, chemical calculation of dipole moments in a group of substituted phenols. J. Chromatogr. 1982, 234, 303–311. [Google Scholar] [CrossRef]
Table 1. QSRR models describing the retention of 94 metabolite standards for each chromatographic based on Equation (2).
Table 1. QSRR models describing the retention of 94 metabolite standards for each chromatographic based on Equation (2).
MDs (Amide)Adjustable Parameters (Amide)MDs (Bare Silica)Adjustable Parameters (Bare Silica)
tpsaEfficiency9.64 ± 0.85tpsaEfficiency8.02 ± 0.88
XLogP−0.84 ± 0.14nA3.73 ± 0.57
nBase3.37 ± 0.42nHBAcc0.35 ± 0.10
MDEC.330.25 ± 0.08fr_C_O_noCOO1.48 ± 0.31
nR−8.77 ± 2.64fr_NH1−1.49 ± 0.50
C2SP30.24 ± 0.10khs.sNH21.02 ± 0.41
1.8/7.8/2.3 1 2.0/6.7/2.5 1
1 Average absolute difference of experimental and calculated tR/Maximum absolute difference of experimental and calculated tR/Standard error of the estimate SEE.
Table 2. QSRR model describing the retention of 94 metabolite standards for the Amide column based on Equation (1) and using their retention data on the Bare Silica column as a reference column.
Table 2. QSRR model describing the retention of 94 metabolite standards for the Amide column based on Equation (1) and using their retention data on the Bare Silica column as a reference column.
MDs/tR(R)Adjustable Parameters
tpsaEfficiency5.62 ± 0.81
XLogP−0.53 ± 0.11
nBase0.67 ± 0.46
MDEC.330.24 ± 0.60
nR−1.49 ± 2.19
C2SP30.03 ± 0.08
tR(R)0.60 ± 0.07
1.3/4.2/1.7 1
1 Average absolute difference of experimental and calculated tR/Maximum absolute difference of experimental and calculated tR/Standard error of the estimate SEE.
Table 3. QSRR models describing the retention of each of four groups of chemically related compounds for Amide column based on Equations (1) and (2), where in Equation (1) the Bare Silica column is used as a reference column.
Table 3. QSRR models describing the retention of each of four groups of chemically related compounds for Amide column based on Equations (1) and (2), where in Equation (1) the Bare Silica column is used as a reference column.
Metabolites Chemical GroupMDsAdjustable Parameters of Equation (2)MDs/tR(R)Adjustable Parameters of Equation (1)
SugarstpsaEfficiency13.07 ± 0.91tpsaEfficiency13.51 ± 0.94
nHBAcc0.53 ± 0.06nHBAcc0.24 ± 0.23
tR(R)0.36 ± 0.17
0.7/2.1/1.0 1 0.6/1.9/0.9 1
Amino acidstpsaEfficiency6.86 ± 1.79tpsaEfficiency2.63 ± 0.47
MinPartialCharge−13.36 ± 1.87MinPartialCharge0.72 ± 0.77
nHBAcc0.76 ± 0.21nHBAcc0.11 ± 0.06
tR(R)0.95 ± 0.04
1.1/4.3/1.5 1 0.3/0.8/0.4 1
MDEC.330.80 ± 0.25MDEC.330.39 ± 0.10
XLogP−1.76 ± 0.33XLogP−0.42 ± 0.17
khs.sNH25.47 ± 1.42khs.sNH20.26 ± 0.70
nHBAcc0.88 ± 0.26nHBAcc−0.33 ± 0.15
tR(R)1.50 ± 0.10
2.8/8.4/1.8 1 0.4/1.5/0.6 1
Nucleonic bases-nucleosidestpsaEfficiency14.93 ± 1.21tpsaEfficiency7.24 ± 3.9
tR(R)0.92 ± 0.45
2/4.2/2.4 1 1.7/3.1/2.1 1
1 Average absolute difference of experimental and calculated tR/Maximum absolute difference of experimental and calculated tR/Standard error of the estimate SEE.
Table 4. QSRR models, based on Equation (2), describing the retention of tryptophan and its major metabolites for each chromatographic column.
Table 4. QSRR models, based on Equation (2), describing the retention of tryptophan and its major metabolites for each chromatographic column.
Three-Parameter QSRR Model
EVOGemini
MDsG1G2G3G4G1G2G3G4
pKa1−0.82 ± 0.30−0.60 ± 0.32−0.61 ± 0.24−0.41 ± 0.50−1.08 ± 0.30−0.74 ± 0.37−0.71 ± 0.15−0.56 ± 0.65
pKa21.17 ± 0.130.86 ± 0.141.01 ± 0.110.73 ± 0.221.52 ± 0.131.09 ± 0.181.27 ± 0.070.93 ± 0.29
logP2.30 ± 0.571.96 ± 0.621.63 ± 0.472.36 ± 0.962.91 ± 0.582.04 ± 0.762.24 ± 0.292.22 ± 1.05
1.2/2.8/1.9 11.3/3.1/2.1 11.0/2.4/1.6 11.8/5.8/3.2 11.1/2.9/1.9 11.6/3.6/2.5 10.6/1.4/1.0 12.5/6.9/4.2 1
1 Average absolute difference of experimental and calculated tR/Maximum absolute difference of experimental and calculated tR/Standard error of the estimate SEE.
Table 5. QSRR models, based on Equation (1), describing the retention of tryptophan and its major metabolites for each chromatographic column using the other column as a reference one.
Table 5. QSRR models, based on Equation (1), describing the retention of tryptophan and its major metabolites for each chromatographic column using the other column as a reference one.
Three-Parameter QSRR Model
EVOGemini
MDs/tR(R)G1G2G3G4G1G2G3G4
pKa10.15 ± 0.27−0.07 ± 0.210.42 ± 0.28−0.03 ± 0.26−0.33 ± 0.23−0.08 ± 0.26−0.37 ± 0.11−0.08 ± 0.34
pKa2−0.20 ± 0.330.08 ± 0.21−0.82 ± 0.450.08 ± 0.190.46 ± 0.260.13 ± 0.260.70 ± 0.140.08 ± 0.25
logP−0.31 ± 0.680.50 ± 0.49−1.61 ± 0.820.82 ± 0.600.82 ± 0.57−0.13 ± 0.681.33 ± 0.26−0.54 ± 0.91
tR(R)0.90 ± 0.210.72 ± 0.181.44 ± 0.350.69 ± 0.170.91 ± 0.221.11 ± 0.280.56 ± 0.141.17 ± 0.28
0.6/0.9/0.9 10.6/1.2/1.0 10.5/0.7/0.7 11.0/1.5/1.6 10.6/1.0/0.9 10.7/1.6/1.3 10.3/0.6/0.5 11.2/2.4/2.0 1
1 Average absolute difference of experimental and calculated tR/Maximum absolute difference of experimental and calculated tR/Standard error of the estimate SEE.

Share and Cite

MDPI and ACS Style

Zisi, C.; Sampsonidis, I.; Fasoula, S.; Papachristos, K.; Witting, M.; Gika, H.G.; Nikitas, P.; Pappa-Louisi, A. QSRR Modeling for Metabolite Standards Analyzed by Two Different Chromatographic Columns Using Multiple Linear Regression. Metabolites 2017, 7, 7. https://doi.org/10.3390/metabo7010007

AMA Style

Zisi C, Sampsonidis I, Fasoula S, Papachristos K, Witting M, Gika HG, Nikitas P, Pappa-Louisi A. QSRR Modeling for Metabolite Standards Analyzed by Two Different Chromatographic Columns Using Multiple Linear Regression. Metabolites. 2017; 7(1):7. https://doi.org/10.3390/metabo7010007

Chicago/Turabian Style

Zisi, Chrysostomi, Ioannis Sampsonidis, Stella Fasoula, Konstantinos Papachristos, Michael Witting, Helen G. Gika, Panagiotis Nikitas, and Adriani Pappa-Louisi. 2017. "QSRR Modeling for Metabolite Standards Analyzed by Two Different Chromatographic Columns Using Multiple Linear Regression" Metabolites 7, no. 1: 7. https://doi.org/10.3390/metabo7010007

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop