Next Article in Journal
Non-Targeted Metabolomics Analysis of Golden Retriever Muscular Dystrophy-Affected Muscles Reveals Alterations in Arginine and Proline Metabolism, and Elevations in Glutamic and Oleic Acid In Vivo
Previous Article in Journal
The Effect of Season on the Metabolic Profile of the European Clam Ruditapes decussatus as Studied by 1H-NMR Spectroscopy
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Rapid Quantification of Major Volatile Metabolites in Fermented Food and Beverages Using Gas Chromatography-Mass Spectrometry

by
Farhana R. Pinu
1,* and
Silas G. Villas-boas
2
1
The New Zealand Institute for Plant & Food Research Limited, Private Bag 92169, Auckland 1142, New Zealand
2
School of Biological Sciences, University of Auckland, Private Bag 92019, Auckland 1010, New Zealand
*
Author to whom correspondence should be addressed.
Metabolites 2017, 7(3), 37; https://doi.org/10.3390/metabo7030037
Submission received: 3 July 2017 / Revised: 17 July 2017 / Accepted: 25 July 2017 / Published: 26 July 2017

Abstract

:
Here we present a method for the accurate quantification of major volatile metabolites found in different food and beverages, including ethanol, acetic acid and other aroma compounds, using gas chromatography coupled to mass spectrometry (GC-MS). The method is combined with a simple sample preparation procedure using sodium chloride and anhydrous ethyl acetate. The GC-MS analysis was accomplished within 4.75 min, and over 80 features were detected, of which 40 were positively identified using an in-house and a commercial mass spectrometry (MS) library. We determined different analytical parameters of these metabolites including the limit of detection (LOD), limit of quantitation (LOQ) and range of quantification. In order to validate the method, we also determined detailed analytical characteristics of five major fermentation end products including ethanol, acetic acid, isoamyl alcohol, ethyl-L-lactate and, acetoin. The method showed very low technical variability for the measurements of these metabolites in different matrices (<3%) with an excellent accuracy (100 ± 5%), recovery (100 ± 10%), reproducibility and repeatability [Coefficient of variation (CV) 1–10%)]. To demonstrate the applicability of the method, we analysed different fermented products including balsamic vinegars, sourdough, distilled (whisky) and non-distilled beverages (wine and beer).

Graphical Abstract

1. Introduction

Gas chromatography and mass spectrometry (GC-MS) in one of the most mature analytical technologies that provides excellent chromatographic resolution due to the high sensitivity and specificity of mass spectrometry [1]. GC-MS has always been the most preferred analytical platform for the analysis of volatile metabolites present in different biological samples including food and beverages. Therefore, many methods are already available that make use of headspace (HS) and solid-phase micro extraction (SPME) techniques in order to quantify volatile compounds accurately in fermented food and beverage samples [2,3,4,5,6]. However, HS analysis requires a large sample volume and SPME requires expensive fibres for effective extraction of volatile metabolites. On the other hand, liquid injection GC-MS offers a cheaper and more straightforward option for the analysis of major fermentation end products (e.g., ethanol, acetic acid, higher alcohols, esters and volatile fatty acids, Figure 1) with an advantage of being able to identify other volatile metabolites easily that are commonly found in fermented products.
Volatile metabolites, usually present in ng/L to g/L, play very important roles in sensory properties of different fermentation products (Figure 1). Although some of them are already present in the raw materials (e.g., fruits, grains), they can also be produced by the activities of different microorganisms including bacteria, yeast and other fungi. Therefore, their concentrations increase significantly in the final fermented product, as compared to the initial raw material. For instance, ethanol and acetic acid are the two major fermentation end products found in various food and beverages. Therefore, quantification of ethanol and acetic acid in food and alcoholic beverages is well established in biological samples using different analytical and enzymatic approaches [7,8,9,10]. But most of these methods do not offer the same sensitivity and, most importantly, accuracy if compared to GC-MS. As such, dichromate oxidation spectrophotometry [11], densimetric analysis [12], refractive index method [12,13] and near-infrared spectroscopy [14,15] have been used for quantification of ethanol for many years. However, these methods require large sample volume and/or pre-treatment (e.g., distillation) of samples that make them not ideal for small sample sizes [16]. Enzymatic assays are also commonly used to quantify ethanol and acetic acid in biological samples [8,9,17]. However, the reproducibility of the enzyme-based methods is not good due to instability of enzymes. Moreover, enzymatic reactions are highly influenced by the matrix of the samples. On the other hand, several chromatographic methods have been reported for quantification of ethanol and acetic acid, mostly using high performance liquid chromatography (HPLC) and gas chromatography coupled to flame ionisation detector (GC-FID) [16,18,19,20,21]. HPLC methods provide poor chromatographic resolution when analysing complex matrices [16], and the commonly used detectors in HPLC-based methods (UV and refractive index) are unable to distinguish co-eluting metabolites. Similarly, FID presents very low specificity [20].
Given that the concentration of volatile metabolites varies widely (Figure 1) in different fermented products, it is always a challenging task to develop the analytical pipelines that would allow simultaneous quantification of them (as many as possible) in a single run using comparatively a small amount of sample and minimum sample preparation.
Although many methods are already available for the analysis of volatile compounds, however, there is still an ongoing demand for developing a method that is quick, inexpensive and requires only a small amount of samples, yet accurate. Therefore, we aimed to develop such a method for the global analysis of volatile metabolites. Here, we present a direct injection GC-MS method for the quantification (and profiling) of different fermentation end products in food products and beverages, which combine the high specificity of electron impact (EI) mass spectrometry with the high reproducibility and high chromatographic resolution of gas chromatography.

2. Results and Discussion

2.1. Method Validation

Although our initial aim was to develop a rapid, reproducible and inexpensive GC-MS method to accurately quantify ethanol and acetic acid simultaneously in various fermented food products and beverages using only 100 µL of sample (Figure 2), we were also able to detect over 70 features only within 4.75 min while using 1000 µL of sample (Table 1). Therefore, this method has potential for volatile metabolite profiling when large volume of biological samples are not available.
We also identified over 40 volatile metabolites (Table 1) including 14 alcohols (higher alcohols and one terpene alcohol, linalool), 10 volatile organic acids, 12 esters (both ethyl and acetate esters) and five aldehyde and ketones using both reference standards (in-house MS library) and NIST (National Institute of Standards and Technology) library. Therefore, this method clearly shows its potential for the determination of different groups of volatile compounds. To the very best of our knowledge, this is the first method that covers the quantification of a wide range of volatile compounds only within 5 min using small amount of samples (100–1000 µL).
We determined different analytical parameters of all 40 metabolites including the limit of detection (LOD), limit of quantitation (LOQ) and range of quantification. We obtained excellent linearity for all the metabolites (Table 1). Moreover, LOD varies from 0.1 mg/L to 20 mg/L, while LOQ was within 0.5–50 mg/L depending on the chemical properties of metabolites. For instance, LOD of ethanol and acetic acid was 0.5 mg/L and 0.4 mg/L respectively, and LOQ was 2 mg/L for ethanol and 1.5 mg/L for acetic acid when only 100 µL samples were used, which make this a more sensitive method for analysis of these common fermentation products than other published GC-FID and HPLC methods [7,10,18,20]. Therefore, this method is indeed suitable for the quantification of different metabolites that are present in mg/L to g/L. It is noteworthy that other published methods make use of at least 10–50 mL of samples using either HS or SPME extraction and sample concentration step in order to quantify volatiles present in µg/L or below [2,5,22]. On the contrary, we only used 100–1000 µL of samples using a very simple sample preparation protocol to achieve these extensive ranges of quantification (0.5–350000 mg/L) of 40 different volatile metabolites. Moreover, the samples were injected to GC at 100:1 split ratio. Therefore, it is possible to achieve even better LOD and LOQ by increasing the volume of samples extracted by ethyl acetate as well as by reducing the split ratio [23].
Our chosen internal standard was D4-methanol, which is an unnatural compound that elutes separately before most of the metabolites, making it an appropriate internal standard for this method (retention time in Table 1). Excellent repeatability and reproducibility results were obtained for five major volatiles (ethanol, acetic acid, ethyl-L-lactate, isoamyl alcohol and acetoin) with less than 4.6% technical variability (RSD) using seven different matrices (Table 2). Similarly, the intra- and inter-day variability for all these metabolites was also below 5% (Table 2). All these results indicate that the precision of our method is high. In addition, the method showed excellence accuracy and the overall recovery of five major fermentation end products in five different matrices was 100.0% ± 6.0% (Table 3), which confirms that this method is able to quantify these volatile metabolites accurately in wide ranges of fermented beverages and food products.
The choice of extraction solvents depends on the polarity of the metabolites of interest and organic solvents are mostly used as they allow the precipitation of proteins present in the samples [24]. While aqueous solutions of methanol, acetonitrile, and isopropanol are suitable for the extractions of polar metabolites [24], pure organic solvents (e.g., ethyl acetate, hexane) are able to extract volatile fraction of metabolome of a given biological samples. We choose ethyl acetate as the solvent for extraction of volatile compounds from water-based samples because it has very low solubility in water (8.3 mg/100 mL) [25] and it has high partition co-efficient for ethanol, acetic acid and other volatiles in aqueous solution [20]. In addition, anhydrous NaCl was added to the sample during extraction in order to increase the polarity of the aqueous layer and maximise extraction of volatile compounds [26]. By comparing samples extracted in presence and absence of NaCl, we observed a much better reproducibility and accuracy of analysis when NaCl was used (data not shown).

2.2. Applicability of the Method

We analysed six different types of fermented food and beverages including sourdough (n = 3), balsamic vinegars (n = 6), whiskies (n = 3), beers (n = 3), red (n = 3) and white wines (n = 3) to determine the applicability of the method for the quantification of major volatile metabolites (Table 4). Although this method is able to detect and quantify over 40 volatiles present in a sample, we identified and successfully quantified 18 of the volatile metabolites in the samples analysed in this study. Among them, only five metabolites were present in all the samples including ethanol, acetic acid, acetoin, 2,3-butanediol and phenylethyl alcohol. Their concentrations in various fermented food and beverages (65–33078 mg/L) also indicates that these are the major fermentation end products in those samples.
Ethanol was undoubtedly the most abundant and common metabolites present in concentrations well above g/L in all the samples analysed, which was expected. For instance, ethanol concentrations in the wines ranged from 93.34 g/L to 108.25 g/L, which were very similar to the concentrations mentioned in the wine labels (recovery: 98.89–101.61%) (Table 4). Similarly, we also determined the ethanol content in three distilled spirits (307.32–372.98 g/L) and three different beers (36.64–55.78 g/L) (Table 4). These values were very close to the concentrations provided by the manufacturers, which again shows the potentiality of using this method for the analysis of ethanol in many alcoholic beverages with wide range of ethanol concentrations. In addition, we also determined the ethanol concentration in six balsamic vinegars (1.24–2.27 g/L) and three sourdough samples (1.5–1.75 g/L) (Table 4), which indicates that this method also can be used to quantify ethanol in food products with comparatively low ethanol content.
Acetic acid is the second most common and abundant volatile metabolite present in different fermented food and beverages. Table 4 shows the concentration of acetic acid in alcoholic beverages, sourdough and vinegar samples. The acidity of balsamic vinegars was mentioned as approximately 6% v/v in the bottles and our data show that acetic acid concentration varied from 5.24% v/v (55.02 g/L) to 6.31% v/v (66.25 g/L), which were very close to the value mentioned by the manufacturers. The acetic acid concentration in beer and whisky samples ranged from 0.11 g/L to 0.37 g/L, and it was mostly below 0.57 g/L for both red and white wines, which is expected because acetic acid is considered an off-flavour in many beverages (Table 4). However, one red wine showed more than 0.88 g/L of acetic acid, which might produce a pungent flavour in the wines [27].
The overall volatile metabolite profile largely depended on the type of samples analysed during this study. For instance, the concentrations of alcohol and higher alcohols were comparatively higher in whisky samples as expected, while almost no volatile organic acids and esters (except diethyl succinate) were detected in them. It is well known that whisky is a distilled beverage, thus only the major alcohols remained in them after the distillation process [28]. Although some volatile compounds usually develop during maturation [28], it is possible that most of the organic acids and esters are present in too low concentrations to be detected by our method. In addition to this, wines also had the most distinct volatile metabolite profiles and some of the metabolites were uniquely present in different types of wines. For example, two c6 compounds (cis-3-hexen-1-ol and hexyl acetate), also known as green leaf volatiles, were only detected in wine samples. However, they could only be quantified in white wines (Table 4). All these white wines were produced in New Zealand where machine harvesting is mostly used method. Therefore, these volatile compounds most probably originated during the crushing process of the grapes along with the leaves [29] and a minor amount also can be produced by the metabolic activities of wine yeasts [30]. Similarly, a naturally occurring terpene alcohol, linalool, which contributes to the floral notes in wines [31], was also only detected in both of types of wines, although under limit of quantification (Table 4).

3. Materials and Methods

3.1. Chemicals

All chemicals used in this study were of analytical grade. Internal standard tetradeuteromethanol (D4-methanol; 99.8%) was purchased from Cambridge Isotope Laboratories, Inc. (Andover, MA, USA). The solvent anhydrous ethyl acetate (99.8%), ethanol standard (99.5%), and all other volatile metabolite standards were obtained from Sigma-Aldrich (St. Louis, MO, USA), except acetone (99%) and acetic acid (99.8%), which were purchased from Biolab (Scoresby, Australia). All solutions were prepared using Grade 1 water (BARNSTEAD® NANOpure DiamondTM Water Purification System, Waltham, MA, USA) or absolute ethanol or absolute methanol (UNIVAR, AJAX FINECHEM, Auckland, New Zealand).

3.2. Sample Preparation

We used only 100 µL of sample to quantify ethanol and acetic acid in different samples. However, 1000 µL of samples were needed to determine the concentrations of other volatile metabolites. The samples were mixed with 10 µL of internal standard (D4-methanol). Approximately 50–300 mg of anhydrous sodium chloride salt was added to the mixture until saturation followed by intense mixing using a vortex mixer for 10–15 s. Then, 500 µL of ethyl acetate was added to the mixture and mixed vigorously for 1 min using a vortex mixer. The samples were then centrifuged for 2 min at 2000× g to separate the aqueous and non-aqueous layers. Approximately 200 µL of the upper non-aqueous phase was transferred to a 2–mL GC-MS vial for analysis.

3.3. GC-MS Analysis

The ethyl acetate extracts were analysed using an Agilent GC 7890 coupled to a MS 5975 (Agilent Technologies, CA, USA) with a quadrupole mass selective detector (electron impact ionisation; positive mode) operated at 70 eV. A Zebron ZB-1701 (Phenomenex), 30 m × 250 µm (internal diameter) × 0.15 µm (film thickness), with 5 m guard column was used for the analysis. 1 μL of sample was injected into the GC under split mode at a 100:1 split ratio under constant flow of 48.851 mL/min on column. Electron impact ionisation (EI) The temperature of the inlet was kept at 180 °C. The GC oven temperature was initially held at 50 °C for 1 min, and then raised to 200 °C at 40 °C/min. The total running time for this method was 4.75 min. The equilibration time was set to 2 min. The interface and quadrupole temperatures were 230 °C and 150 °C respectively. The MS detector was turned off between 2.03 min to 2.21 min to offload ethyl acetate peak. The MS was operated in scan mode with a mass range of 30 to 250 a.m.u. The reference ion (m/z) used for identification and quantification of target compounds as well as internal standard are shown in Table 1. Moreover, we also created an in-house MS library using the standard metabolites and this library contains information about retention time and mass spectra information of over 40 different volatile metabolites commonly found in fermented food and beverages detectable by this method.

3.4. Validation of the Method

The validation of the method was carried out using standard solutions of five major fermentation end products including ethanol, acetic acid, ethyl-L-lactate, isoamyl alcohol and acetoin. Both reproducibility and repeatability of the method were determined using standard solutions of the five major volatile compounds, beer, synthetic wine (mimicking a real wine with 94.68 g/L ethanol, 1 g/L glucose, 1 g/L fructose, 4 g/L malic acid, 2 g/L citric acid, 1 g/L succinic acid, 0.5 g/L lactic acid), red wine, white wine, whisky and balsamic vinegar samples. To assess the repeatability, the same sample was injected five times into the GC-MS in sequence. The reproducibility was assessed by extracting five replicates of each sample with ethyl acetate as described above and injected in sequence into the GC-MS. Intra- and inter-day variability was also assessed using five standard solutions. For the determination of intra-day variability, two replicates containing extracted volatiles were injected three times within a day and one sample was kept at room temperature, while the other sample was stored at −20 °C for three consecutive days. These samples were injected into the GC-MS every day three times in order to determine the inter-day variability. The recovery of five volatile compounds was obtained using synthetic wine, spiked samples (red and white wines), and standard solutions in water.
In addition, limit of detection (LOD) and limit of quantitation (LOQ) of 40 metabolites were also determined and a signal-to-noise ratio of 3:1 and 10:1 were considered as LOD and LOQ respectively [32].

3.5. Application of the Method

Quantification of the major volatile metabolites was performed by creating calibration curves within the ranges of concentrations present in the fermented food and beverages. We then analysed commercial (obtained for local supermarkets) beers (n = 3), red wines (n = 3), white wines (n = 3), whisky (n = 3), balsamic vinegars (n = 3) and sourdough (n = 3) in triplicate to demonstrate the applicability of the method for the quantification of fermentation end products in wide ranges of fermented beverages (Supplementary Table 1). A small amount (~ 10 mg) of activated charcoal was added to the ethyl extracts of red wines, dark beers and balsamic vinegars to overcome matrix effect due to the presence of high concentrations of anthocyanin and polyphenolic compounds. A sample dilution (10×) of distilled spirits was performed while quantifying ethanol in order to fit their concentrations within the linearity range.

4. Conclusions

Here we report the first liquid injection GC-MS method for the quantification of major volatile metabolites present in fermented food and beverages. We obtained excellent accuracy, linearity and reproducibility for quantification of different compounds in sourdough, beers, wines, whisky and balsamic vinegar samples. This method is inexpensive, simple and robust, which makes it suitable for rapid quantitation of many volatiles in different types of fermented foods and beverages. We acknowledge the fact that many other methods for aroma compound analysis are available and previously published, but none of the methods are suitable when small amount of samples are available from an experiment. Moreover, all those published methods requires longer time (>20 min and often over 60 min) to complete the GC-MS analysis. In comparison, the method described here only requires 100–1000 µL of samples and analysis is accomplished below 5 min, which make this proposed method unique and suitable for rapid analysis of volatiles in different types of biological samples. There is an ongoing demand of such method within scientific community. Currently, this method is able to quantify only volatiles present in mg/L to g/L, however, the sample preparation step can be further optimised in order cover the µg/L ranges of concentration. Overall, this method is also suitable for both targeted and untargeted volatile profiling approach.

Supplementary Materials

The following are available online at www.mdpi.com/2218-1989/7/3/37/s1, Supplementary Table 1: The origin of samples used in this study.

Acknowledgments

The funding of this project was provided by New Zealand Winegrowers and New Zealand Institute for Plant & Food Research (PFR) Limited. We thank Dr Elizabeth Mackenzie (Centre for Genomics, Proteomics and Metabolomics, The University of Auckland) and Sergey Tumanov (School of Biological Sciences, The University of Auckland) for their technical suggestions. We also acknowledge the contribution of Dr Bruno Fedrizzi (School of Chemical Sciences, The University of Auckland) who kindly provided standards for some volatile compounds. Dr Aydin Berenjian (University of Waikato) provided sourdough samples. We are also grateful to Science Publishing Office of PFR for their support with proofreading.

Author Contributions

F.R.P. and S.V.B. conceived and designed the experiments; F.R.P. performed the experiments; analyzed the data; and. wrote the paper. S.V.B reviewed the article.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

The following abbreviations are used in this manuscript:
GC-MSGas chromatography-mass spectrometry
LODLimit of detection
LOQLimit of quantification
CVCoefficient of variation
RSDResidual standard deviation

References

  1. Villas-Boas, S.G.; Mas, S.; Akesson, M.; Smedsgaard, J.; Nielsen, J. Mass spectrometry in metabolome analysis. Mass Spectrom. Rev. 2005, 24, 613–646. [Google Scholar] [CrossRef] [PubMed]
  2. Fan, W.; Qian, M.C. Headspace solid phase microextraction and gas chromatography-olfactometry dilution analysis of young and aged chinese “Yanghe Daqu” liquors. J. Agric. Food Chem. 2005, 53, 7931–7938. [Google Scholar] [CrossRef] [PubMed]
  3. Hayaloglu, A.A.; Karabulut, I. SPME/GC-MS characterization and comparison of volatiles of eleven varieties of turkish cheeses. Int. J. Food Prop. 2013, 16, 1630–1653. [Google Scholar] [CrossRef]
  4. Pino, J.A.; Roncal, E. Validation of a HS-SPME-GC method for determining higher fatty esters and oak lactones in white rums. Food Anal. Methods 2015, 1–5. [Google Scholar] [CrossRef]
  5. Zhu, H.; Zhu, J.; Wang, L.; Li, Z. Development of a SPME-GC-MS method for the determination of volatile compounds in shanxi aged vinegar and its analytical characterization by aroma wheel. J. Food Sci. Technol. 2016, 53, 171–183. [Google Scholar] [CrossRef] [PubMed]
  6. Dong, L.; Hou, Y.; Li, F.; Piao, Y.; Zhang, X.; Zhang, X.; Li, C.; Zhao, C. Characterization of volatile aroma compounds in different brewing barley cultivars. J. Sci. Food Agric. 2015, 95, 915–921. [Google Scholar] [CrossRef] [PubMed]
  7. Stackler, B.; Christensen, E.N. Quantitative determination of ethanol in wine by gas chromatography. Am. J. Enol. Vitic. 1974, 25, 202–2007. [Google Scholar]
  8. Lázaro, F.; de Castro, M.D.L.; Valcárcel, M. Individual and simultaneous enzymatic determination of ethanol and acetaldehyde in wines by flow injection analysis. Anal. Chim. Acta 1986, 185, 57–64. [Google Scholar] [CrossRef]
  9. Gonchar, M.V.; Maidan, M.M.; Pavlishko, H.M.; Sibirny, A.A. A new oxidase-peroxidase kit for ethanol assays in alcoholic beverages. Food Technol. Biotechnol. 2001, 39, 37–42. [Google Scholar]
  10. Kupina, S.A. Simultaneous quantitation of glycerol, acetic acid and ethanol in grape juice by high performance liquid chromatography. Am. J. Enol. Vitic. 1984, 35, 59–62. [Google Scholar]
  11. Christensen, L.M.; Fulmer, E.I. Analysis of n-butanol, acetone, and ethanol in aqueous solution. Ind. Eng. Chem. 1935, 7, 180–182. [Google Scholar] [CrossRef]
  12. Latimer, G.W. Official Methods of Analysis of Aoac International; AOAC International: Gaithersburg, MD, USA, 2012; Vol. 19, Available online: http://www.sidalc.net/cgi-bin/wxis.exe/?IsisScript=BFHIA.xis&method=post&formato=2&cantidad=1&expresion=mfn=016229 (accessed on 26 July 2017).
  13. Calull, M.; Marce, R.M.; Borrull, F. Determination of carboxylic acids, sugars, glycerol and ethanol in wine and grape must by ion-exchange high-performance liquid chromatography with refractive index detection. J. Chromatogr. 1992, 590, 215–222. [Google Scholar] [CrossRef]
  14. Zhang, S.M.; Yang, Y.; Ni, Y.Y. Combination of near infrared spectroscopy and electronic nose for alcohol quantification during the red wine fermentation. Guang Pu Xue Yu Guang Pu Fen Xi 2012, 32, 2997–3001. Available online: https://www.ncbi.nlm.nih.gov/pubmed/23387165 (accessed on 26 July 2017). [PubMed]
  15. Garcia-Jares, C.M.; Médina, B. Application of multivariate calibration to the simultaneous routine determination of ethanol, glycerol, fructose, glucose and total residual sugars in botrytized-grape sweet wines by means of near-infrared reflectance spectroscopy. Fresenius J. Anal. Chem. 1997, 357, 86–91. [Google Scholar] [CrossRef]
  16. Wang, M.L.; Choong, Y.M.; Su, N.W.; Lee, M.S. A rapid method for determination of ethanol in alcoholic beverages using capillary gas chromatography. J. Food Drug Anal. 2003, 11, 133–140. [Google Scholar]
  17. Páscoa, R.N.M.J.; Vidigal, S.S.M.P.; Tóth, I.V.; Rangel, A.O.S.S. Sequential injection system for the enzymatic determination of ethanol in wine. J. Agric. Food Chem. 2006, 54, 19–23. [Google Scholar] [CrossRef] [PubMed]
  18. Falqué López, E.; Fernández Gómez, E. Simultaneous determination of the major organic acids, sugars, glycerol, and ethanol by hplc in grape musts and white wines. J. Chromatogr. Sci. 1996, 34, 254–257. [Google Scholar] [CrossRef]
  19. Paredes, E.; Maestre, S.E.; Prats, S.; Todolí, J.L. Simultaneous determination of carbohydrates, carboxylic acids, alcohols, and metals in foods by high-performance liquid chromatography inductively coupled plasma atomic emission spectrometry. Anal. Chem. 2006, 78, 6774–6782. [Google Scholar] [CrossRef] [PubMed]
  20. Gerchman, Y.; Schnitzer, A.; Gal, R.; Mirsky, N.; Chinkov, N. A simple rapid gas-chromatography flame-ionization-detector (GC-FID) method for the determination of ethanol from fermentation processes. Afr. J. Biotechnol. 2012, 11, 3612–3616. [Google Scholar] [CrossRef]
  21. Wang, M.L.; Wang, J.T.; Choong, Y.M. Simultaneous quantification of methanol and ethanol in alcoholic beverage using a rapid gas chromatographic method coupling with dual internal standards. Food Chem. 2004, 86, 609–615. [Google Scholar] [CrossRef]
  22. Campo, E.; Cacho, J.; Ferreira, V. Solid phase extraction, multidimensional gas chromatography mass spectrometry determination of four novel aroma powerful ethyl esters. Assessment of their occurrence and importance in wine and other alcoholic beverages. J. Chromatogr. A 2007, 1140, 180–188. [Google Scholar] [CrossRef] [PubMed]
  23. Wasfi, I.A.; Al-Awadhi, A.H.; Al-Hatali, Z.N.; AI-Rayami, F.J.; AI-Katheeri, N.A. Rapid and sensitive static headspace gas chromatography-mass spectrometry method for the analysis of ethanol and abused inhalants in blood. J. Chromatogr. B 2004, 799, 331–336. [Google Scholar] [CrossRef]
  24. Cajka, T.; Fiehn, O. Toward merging untargeted and targeted methods in mass spectrometry-based metabolomics and lipidomics. Anal. Chem. 2016, 88, 524–545. [Google Scholar] [CrossRef] [PubMed]
  25. Altshuller, A.P.; Everson, H.E. The solubility of ethyl acetate in water. J. Am. Chem. Soc. 1953, 75, 1727. [Google Scholar] [CrossRef]
  26. Shah, D.J.; Tiwari, K.K. Effect of salt on the distribution of acetic acid between water and organic solvent. J. Chem. Eng. Data 1981, 26, 375–378. [Google Scholar] [CrossRef]
  27. Zoecklein, B.W.; Fugelsang, K.E.; Gump, B.H.; Nury, E.S. Wine Analysis and Production; Chapman & Hall: New York, NY, USA, 1995; Available online: http://www.springer.com/gp/book/9781475769678 (accessed on 26 July 2017).
  28. Monica Lee, K.Y.; Paterson, A.; Piggott, J.R.; Richardson, G.D. Origins of flavour in whiskies and a revised flavour wheel: A review. J. Inst. Brew. 2001, 107, 287–313. [Google Scholar]
  29. Allen, T.; Herbst-Johnstone, M.; Girault, M.; Butler, P.; Logan, G.; Jouanneau, S.; Nicolau, L.; Kilmartin, P.A. Influence of grape-harvesting steps on varietal th ol aromas in sauvignon blanc wines. J. Agric. Food Chem. 2011, 59, 10641–10650. [Google Scholar] [CrossRef] [PubMed]
  30. Slegers, A.; Angers, P.; Ouellet, É.; Truchon, T.; Pedneault, K. Volatile compounds from grape skin, juice and wine from five interspecific hybrid grape cultivars grown in Québec (Canada) for wine production. Molecules 2015, 20, 10980–11016. [Google Scholar] [CrossRef] [PubMed]
  31. Vilanova, M.; Genisheva, Z.; Graña, M.; Oliveira, J.M. Determination of odorants in varietal wines from international grape cultivars (Vitis vinifera) grown in nw spain. S. Afr. J. Enol. Vitic. 2013, 34, 212–222. [Google Scholar] [CrossRef]
  32. Schlatter, J.; Chiadmi, F.; Gandon, V.; Chariot, P. Simultaneous determination of methanol, acetaldehyde, acetone, and ethanol in human blood by gas chromatography with flame ionization detection. Hum. Exp. Toxicol. 2014, 33, 74–80. [Google Scholar] [CrossRef] [PubMed]
Figure 1. The structures of well-known major volatile metabolites present in different fermented food and beverages.
Figure 1. The structures of well-known major volatile metabolites present in different fermented food and beverages.
Metabolites 07 00037 g001
Figure 2. Typical gas-chromatography-mass spectrometry (GC-MS) chromatograms obtained from the analysis of beer (a), wine (b), whisky (c) and vinegar (d) ethyl acetate extracts. D = D4-methanol, E = ethanol, W = acetonitrile (from wash solvent), A = acetic acid, IA = isoamyl alcohol, BD = 2,3-butanediol and AT = acetoin.
Figure 2. Typical gas-chromatography-mass spectrometry (GC-MS) chromatograms obtained from the analysis of beer (a), wine (b), whisky (c) and vinegar (d) ethyl acetate extracts. D = D4-methanol, E = ethanol, W = acetonitrile (from wash solvent), A = acetic acid, IA = isoamyl alcohol, BD = 2,3-butanediol and AT = acetoin.
Metabolites 07 00037 g002
Table 1. The analytical characteristics of volatile metabolites detected and identified by Gas-Chromatography and Mass-spectrometry method.
Table 1. The analytical characteristics of volatile metabolites detected and identified by Gas-Chromatography and Mass-spectrometry method.
CompoundsRetention Time (min)Reference IonDetection Limit (mg/L)Quantification Limit (mg/L)Range of Quantification (mg/L)Regression Line (n = 5)Coefficient (r2)
Alcohols
D4-methanol (Internal standard)1.78033-----
Methanol1.78632510100–80000y = 17.926x − 1.5280.9999
Ethanol*1.847310.5*
<0.1+
2*
<1+
1–350000y = 4.321x − 1.237*
y = 2.129x − 0.987+
0.9999*
0.9970+
Isobutanol2.2804351010–50000y = 4.219x − 0.88760.9987
1-butanol2.4175651010–20000y =6.2622x − 0.99140.9979
Isoamyl alcohol2.6985551010–80000y = 9.9944x − 1.410.9950
4-methyl pentanol2.7296941010–50000y = 10.957x − 1.19130.9975
cis-3-hexen-1-ol3.15441124040–6000y = 4.321x − 0.8750.9931
2,3-butanediol3.2045782020–10000y = 5.218x − 1.1020.9901
trans-3-hexen-1-ol3.20067205050–7000y = 2.135x − 0.29810.9912
2-pentanol3.4974581212–50000y = 20.032x − 0.29810.9996
1,3-propandiol3.5695710.62525–10000y = 0.0164x + 0.10130.9968
1-phenylethyl alcohol4.237107102020–20000y = 0.2937x + 7.29030.9976
2-phenylethyl alcohol4.50891102020–20000y = 0.392x + 8.98520.9930
Aldehydes and ketones
Acetone1.96258388–50000y = 0.1551x + 0.84780.9945
Acetoin2.72143166–20000y = 0.1352x + 0.53210.9951
Hexenal2.80456388–10000y = 1.098x + 0.02510.9904
2-hexenal3.17543133–9000y = 2.198x + 0.9840.9913
Butyrolactone3.96342NDNDNDNDND
Volatile acids
Acetic acid*2.346430.4*
<0.1+
1.5*
<0.5+
1.5–50000y = 0.1247x + 0.875*
y = 0.0987x + 0.654+
0.9956*
0.9942+
Propanoic acid2.89074155–10000y = 0.0756x + 0.58210.9986
Isobutyric acid3.0537312.52.5–12000y = 0.1429x + 2.36510.9972
Butyric acid3.24960122–10000y = 0.1049x + 4.28990.9980
Isovaleric acid3.42660155–8000y = 0.1256x + 1.20980.9976
Valeric acid3.674600.922–9500y = 0.1109x + 5.14810.9993
Hexanoic acid4.05660488–9500y = 0.1142x + 2.60980.9991
3-hydroxybutyric acid4.2816051010–10000y = 0.0253x + 0.01380.9990
Heptanoic acid4.5807391616–30000y = 0.345x + 4.2190.9870
Octanoic acid4.6906081414–20000y = 0.536x + 5.4530.9840
Esters
Ethyl isobutyrate2.5084381212–10000y = 0.536x + 5.4530.9912
Isobutyl acetate2.6004381212–10000y = 0.536x + 5.4530.9943
Ethyl butanoate2.7007181212–10000y = 0.536x + 5.4530.9950
Pyruvic aldehyde dimethyl acetate2.9017581212–10000y = 0.536x + 5.4530.9933
Ethyl-L-lactate3.03075155–20000y = 0.0545x + 0.09530.9985
Isoamyl acetate3.10270244–20000y = 0.0786x + 0.1280.9956
Ethyl caproate3.6208881515–10000y = 0.0037x + 0.00580.9993
Hexyl acetate3.70684155–15000y = 1.235x − 0.9860.9912
Ethyl caprylate4.39988466–10000y = 0.3509x + 3.00320.9943
Diethyl succinate4.580101155–10500y = 0.4808x + 2.83970.9958
Diethyl malate5.002117155–10000y = 0.5632x + 1.2980.9987
Others
Linalool4.1237151010-5000y = 4.437x − 1.2350.9965
* using 100 µL of sample; + using 500 µL of sample and ND = not determined.
Table 2. The precision of quantification of major fermentation end products using gas chromatography-mass spectrometry (GC-MS) analysis in different matrices.
Table 2. The precision of quantification of major fermentation end products using gas chromatography-mass spectrometry (GC-MS) analysis in different matrices.
MatrixEthanolAcetic AcidEthyl-L-lactateIsoamyl AlcoholAcetoin
Precision (RSD %)Precision (RSD %)Precision (RSD %)Precision (RSD %)Precision (RSD %)
RTRPRTRPRTRPRTRPRTRP
Standard solution (Intra-day)0.81.10.81.01.21.60.71.11.31.7
Standard solution (Inter-day)3.44.23.84.42.02.51.82.12.54.5
Beer2.72.51.32.52.03.21.52.13.23.6
Red wine1.82.32.22.63.03.22.44.12.33.5
Synthetic wine1.11.62.02.63.13.32.12.63.33.9
White wine1.52.12.53.02.83.63.24.53.54.6
Whisky1.71.83.44.1NDND2.12.73.84.2
Vinegar1.21.31.31.63.43.94.14.52.23.5
RSD = Relative standard deviation; RT = Repeatability (n = 5); RP = Reproducibility (n = 5) and ND = not detected.
Table 3. The recovery of major volatiles in five different matrices.
Table 3. The recovery of major volatiles in five different matrices.
Matrix
Standard solution 1Standard solution 2Spiked synthetic wineSpiked red wineSpiked white wine
EthanolActual concentration (mg/L)7.89394.594680.0149910.0126260.0
Determined concentration (mg/L)7.93 ± 0.22394.3 ± 0.7694780.2 ± 340.3151410.2 ± 1200.0126220.3 ± 980.3
Recovery (%)101.5199.95100.1010199.97
Acetic acidActual concentration (mg/L)5.05630 .0450.08801200.0
Determined concentration (mg/L)5.07 ± 0.03629.2 ± 9.7447.5 ± 5.8885.9 ± 9.51208.2 ± 7.4
Recovery (%)100.3999.8799.44100.67100.67
Ethyl-L-lactateActual concentration (mg/L)10.5030.4570.25500.601000.2
Determined concentration (mg/L)10.95 ± 0.1330.50 ± 0.2569.88 ± 0.79515.55 ± 20.21062.8 ± 11.1
Recovery (%)104.28100.1699.47102.98106.25
Isoamyl alcoholActual concentration (mg/L)20.5500.01500.05250.02500.5
Determined concentration (mg/L)20.9 ± 3.5501.8 ± 10.31450.3 ± 30.55215.8 ± 12.92543.5 ± 50.6
Recovery (%)101.95100.3696.6799.34101.72
AcetoinActual concentration (mg/L)12.550.0250.51045.0555.0
Determined concentration (mg/L)12.6 ± 1.549.3 ± 0.55251.5 ± 6.51032.1 ± 22.1561.8 ± 8.1
Recovery (%)100.898.52100.4098.76101.22
Recovery (%) is shown in bold.
Table 4. Concentration of major volatile metabolites present in different fermented food and beverage.
Table 4. Concentration of major volatile metabolites present in different fermented food and beverage.
MetaboliteConcentration In Fermented Food and Beverages (mg/L)
Sourdough (n = 3)Balsamic vinegars (n = 6)Beer (n = 3)Red wine (n = 3)White wine (n = 3)Whisky (n = 3)
Ethanol1750.85 ± 200.181900.78 ± 750.4748730.98 ± 6000.99107150.25 ± 5500.5195890.45 ± 8700.64330780.89 ± 90000.64
Acetic acid1398.55 ± 65.995910.62 ± 300.78300.12 ± 20.66455.17 ± 145.10260.18 ± 79.2450.29 ± 32.99
Acetoin200.76 ± 45.661558.87 ± 400.34100.78 ± 45.62240.66 ± 98.24100.42 ± 65.4360.35 ± 10.92
Propanoic acid110.45 ± 22.38750.92 ± 100.27150.36 ± 20.99198.26 ± 35.77120.11 ± 39.90ND
Butyric acid200.65 ± 26.21890.45 ± 76.27160.91 ± 10.87155.21 ± 86.10145.78 ± 14.28ND
2,3-butanediol167.26±15.55300.99 ± 90.81100.24 ± 26.87500.25 ± 155.42321.85 ± 109.2665.12 ± 10.78
cis-3-hexen-1-olNDNDNDULQ100.76 ± 80.22ND
Isoamyl alcoholULQ240.99 ± 56.71105.50 ± 28.91300.97 ± 109.28230.89 ± 56.20500.98 ± 120.90
1-butanolULQ120.98 ± 17.58100.11 ± 9.87110.27 ± 4.78ULQ200.90 ± 56.72
1-pentanolNDNDNDULQULQ145.87 ± 34.99
Phenylethyl alcohol100.10 ± 23.98200.34 ± 55.40100.21 ± 45.99450.92 ± 100.21300.65 ± 145.12240.98 ± 48.92
LinaloolNDNDNDULQULQND
Ethyl-L-Lactate110.99 ± 9.76230.97 ± 56.78105.67 ± 20.98500.98 ± 200.17300.97 ± 87.22ULQ
Phenyl ethyl acetateULQULQULQ140.43 ± 32.88100.35 ± 4.90ND
Diethyl succinateULQ150.97 ± 34.55120.97 ± 16.38206.76 ± 23.76130.98 ± 76.12100.24 ± 6.54
Diethyl malateULQ100.65 ± 54.98ULQ100.89 ± 23.19120.97 ± 32.90ND
Ethyl caprylateULQULQULQ167.98 ± 34.89104.51 ± 4.31ND
Hexyl acetateNDULQULQULQ109.26 ± 3.78ND
ULQ = under limit of quantitation; ND = not detected.

Share and Cite

MDPI and ACS Style

Pinu, F.R.; Villas-boas, S.G. Rapid Quantification of Major Volatile Metabolites in Fermented Food and Beverages Using Gas Chromatography-Mass Spectrometry. Metabolites 2017, 7, 37. https://doi.org/10.3390/metabo7030037

AMA Style

Pinu FR, Villas-boas SG. Rapid Quantification of Major Volatile Metabolites in Fermented Food and Beverages Using Gas Chromatography-Mass Spectrometry. Metabolites. 2017; 7(3):37. https://doi.org/10.3390/metabo7030037

Chicago/Turabian Style

Pinu, Farhana R., and Silas G. Villas-boas. 2017. "Rapid Quantification of Major Volatile Metabolites in Fermented Food and Beverages Using Gas Chromatography-Mass Spectrometry" Metabolites 7, no. 3: 37. https://doi.org/10.3390/metabo7030037

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop