Next Article in Journal
Linoleic Acid: A Nutritional Quandary
Previous Article in Journal
Acceptance and Commitment Therapy for Inpatients with Psychosis (the REACH Study): Protocol for Treatment Development and Pilot Testing
Previous Article in Special Issue
Knowledge, Attitude and Behaviours towards Recommended Vaccinations among Healthcare Workers
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Microbiota and Particulate Matter Assessment in Portuguese Optical Shops Providing Contact Lens Services

1
GIAS, Escola Superior de Tecnologia da Saúde de Lisboa—ESTeSL, Instituto Politécnico de Lisboa, 1990-096 Lisbon, Portugal
2
Centro de Investigação em Saúde Pública Escola Nacional de Saúde Pública, Universidade Nova de Lisboa, 1600-560 Lisbon, Portugal
3
Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, 2695-066 Loures, Portugal
*
Author to whom correspondence should be addressed.
Healthcare 2017, 5(2), 24; https://doi.org/10.3390/healthcare5020024
Submission received: 18 March 2017 / Revised: 3 May 2017 / Accepted: 9 May 2017 / Published: 15 May 2017
(This article belongs to the Special Issue Occupational Health Issues in the New Millennium)

Abstract

:
The aim of this work was to assess the microbiota (fungi and bacteria) and particulate matter in optical shops, contributing to a specific protocol to ensure a proper assessment. Air samples were collected through an impaction method. Surface and equipment swab samples were also collected side-by-side. Measurements of particulate matter were performed using portable direct-reading equipment. A walkthrough survey and checklist was also applied in each shop. Regarding air sampling, eight of the 13 shops analysed were above the legal requirement and 10 from the 26 surfaces samples were overloaded. In three out of the 13 shops fungal contamination in the analysed equipment was not detected. The bacteria air load was above the threshold in one of the 13 analysed shops. However, bacterial counts were detected in all sampled equipment. Fungi and bacteria air load suggested to be influencing all of the other surface and equipment samples. These results reinforce the need to improve air quality, not only to comply with the legal requirements, but also to ensure proper hygienic conditions. Public health intervention is needed to assure the quality and safety of the rooms and equipment in optical shops that perform health interventions in patients.

1. Introduction

Contact lenses are used for refractive correction, cosmetic enhancement, and other therapeutic reasons [1]. The number of contact lens wearers worldwide have been estimated as high as 140 million in 2005 [2]. Although no definite statistics are available regarding contact lens use in Portugal, an increasing number of the Portuguese population using soft contact lenses is observed. An international survey of contact lens prescribing for presbyopia shows that Portugal is one of the countries with higher levels of prescriptions (79%) for this condition alone [3]. The prevalence of lens-related complications is rising and is reported to be between 20.58% [4] and 50% [5]. Young males [2] are reported as the most affected by lens-related complications. The presence of bacteria, protozoa, and fungi on contact lenses predispose the patient to infections [6]. Different pathogenic organisms have been identified following the introduction of soft lenses in 1970s, with staphylococci and pseudomonas being the most common [4,6,7]. Microbial keratitis has a low prevalence, but is a serious condition that may be associated with hospital admission, time off from work, increasing the cost of medications and back-up spectacles [4]. This condition in contact lens wearers is mainly a bacterial process. However, Acanthamoeba have been associated with contact lens-related infections [4]. Fungal infections are uncommon, though some cases of Fusarium keratitis have been reported [8,9,10]. In addition, particle matter may serve as a favourable medium for the persistence of numerous species of fungi and bacteria, which may release allergens and toxins that exert different health effects [11], and may also be a vehicle for microbiota resuspension and dispersion [12].
There are no universal guidelines regarding the decontamination of ophthalmic instruments [13]. Infections may be transmitted from patient to staff or staff to patients by direct contact (with tears and mucous membranes), aerosol formation, or contamination of equipment [14].
Airborne microorganisms (a part of bioaerosol composition) can originate not only from humans (including patients), but can also be disseminated by diverse indoor characteristics (ventilation, equipment, and materials) and outdoor environmental sources [14,15,16,17,18]. In addition, surfaces (walls and floors) can be a deposit of nutrients and, consequently, potentiate microorganism proliferation that can be dispersed in air due to different activities [19].
In Portugal, orthoptists and optometrists manage the majority of contact lens adaptations at optometric clinics or optical shops within the private sector. In 2013 the number of optical shops in Portugal was 1540 [20].
Recent Portuguese legislation established new limit values for microbiological air load in indoor environments [21], replacing the previous legislation [22]. In the previous legislation, a critical limit of 500 CFU/m3 was defined as the threshold for fungi and bacteria concentration. Currently, the legal compliance also defines different evaluations regarding microorganism identification. For fungi, indoor concentrations should be less than outdoor concentrations; and for bacteria, the indoor concentration should not exceed the outdoor concentration by 350 CFU/m3. However, the critical limit of 500 CFU/m3 was applied in guidelines and other studies [23,24,25].
The same regulation presents two references for particulate matter, namely for PM10 (particles with a nominal mean aerodynamic diameter ≤10 μm) and PM2.5 (particles with a nominal mean aerodynamic diameter ≤2.5 μm) in indoor environments. PM10 delineates a subset of inhalable particles (referred to as thoracic particles) that are small enough to penetrate the respiratory tract (e.g., tracheobronchial region) and PM2.5 as an indicator for fine particulate matter based on consideration of particle penetration into the gas-exchange region [26]. Current regulation has an important difference from the previous version [22] using PM2.5 as a reference, because epidemiologic health studies have reported various health effects associated with particles with lower diameter. Therefore, PM2.5 has a smaller and stricter reference value (25 µg/m3) than PM10 (50 µg/m3).
The aim of this study was to assess microbiota (fungi and bacteria) and particle matter in optical shops. Microbiota assessment intended to cover indoor air, ophthalmic instruments, and surface contamination in thirteen optical shops in order to estimate the potential microbiological hazards for the patients and users of these services and health professionals. We also intend to determine the guidelines and legal compliance of the optical shops assessed, contributing to a specific protocol to ensure a proper microbiota and particulate matter assessment.

2. Materials and Methods

2.1. Optical Shops Assessment

A descriptive study was conducted between October 2015 and March 2016, in a total of 13 optical shops from the Lisbon area in Portugal. Ethical standards for the study complied with the Lisbon School of Health Technology requirements (optical shop consent and a declaration of anonymity and confidentiality). A walkthrough survey and checklist was applied in each shop in order to understand the hygiene and disinfection measures taken, the amount of workers present in the shops, the number of clients assisted prior to the microbiota sampling, the presence/absence of a heating ventilation and air conditioning (HVAC) system and other cleaning habits. It is important to note that the majority of the shops assessed did not have the HVAC systems working and in the street shops, the ventilation was provided only through the open door. All of the sampling and measurements were done at the same time of a normal working day.

2.2. Sampling

Air samples consisted mainly of four indoor samples (two for fungi and two for bacteria) and one outdoor sample in each optical shop, to be used as a reference. Air samples of 250 L were collected through an impaction method with a flow rate of 140 L/min (Millipore air Tester, Millipore, Billerica, MA, USA) onto each plate according to manufacturer’s instructions. Two different culture media were used in order to enhance the selectivity for bacterial and fungal populations growth: malt extract agar (MEA) supplemented with chloramphenicol (0.05%) was used for fungi and tryptic soy agar (TSA) supplemented with nystatin (0.2%) was applied for to assess the bacterial load. The air sampling plan followed the guidelines of the national legislation [21].
Surface samples were collected by swabbing corresponding indoor sites with a 10 cm × 10 cm square stencil, disinfected with a 70% alcohol solution between samplings, in line with the requirements [27]. Equipment swab samples were also collected side-by-side. The samples (Table 1) were sealed with parafilm and transported to the laboratory in a cooler bag. All of the collected samples were incubated at 27 °C for 5–7 days (fungi) or at 30 °C for seven days (bacteria). After laboratory processing and incubation of the samples, quantitative (colony-forming units—CFU/m−3 and CFU/m−2) results for fungi and bacteria were obtained, with the exception of samples collected from the assessed equipment. In this last case, prevalence was achieved through the isolate number of each species identified.

2.3. Fungal Identification

Fungal identification was achieved through macro- and microscopic characteristics, as described by Hoog et al. [28]. Macroscopic identification relied in the colony characteristics (e.g., colour, shape, and elevation) and was coupled with microscopic identification by performing microscopic mounts using tease mount or Scotch tape mount and lactophenol cotton blue mount procedures for microscopic identification of the fungal genera (or species, when possible). The prevalence of each fungus was calculated based in the number of isolates obtained from each genera/species/complex and the total number of fungi identified by site or by type of sampling (air, surface, or equipment).

2.4. Particulate Matter and Temperature and Humidity Assessment

Measurements of particulate matter (PM) were performed using portable direct-reading equipment (Lighthouse, model 3016 IAQ, Fremont, CA, USA) that gives information regarding mass concentration (mg × m−3) in five different sizes (PM0.5, PM1, PM2.5, PM5, PM10). Additionally, data related with particle number concentration by each diameter size were also obtained with the same equipment. In this case, particles results were given in six different diameter sizes, namely: 0.3 μm, 0.5 μm, 1 μm, 2.5 μm, 5 μm, and 10 μm. As mentioned in some literature, these data were also collected because they might be more closely correlated with adverse PM health effects [29,30]. One measurement with the duration of 5 min was done in each sampling as indicated by Portuguese legislation, and the results were obtained by calculating the average for each sampling period. This period of time was considered representative of the type of occupancy and tasks developed.
Simultaneously to the particulate matter assessment, temperature and relative humidity were also monitored through the same equipment and according to the International Standard ISO 7726:1998.

2.5. Data Analysis

Statistical software SPSS V22 was applied for statistical analysis. The data analysis was performed using univariate descriptive statistics with frequency (n; %), median, and graphical representations appropriate for the nature of the data. The results were considered significant at a 5% significance level. The Shapiro-Wilk test was applied to test data normality. To study the relationship between fungal load, bacteria load, and particle matter, and also to study the previous environmental variables’ relationship with temperature and relative humidity, the Spearman correlation coefficient was applied, since the normality assumption was not verified (p < 0.05). To compare fungal, bacteria load, and particle size concentration between the optical shops that use brooms for cleaning purposes and the ones that do not, a Mann-Whitney test was applied.

3. Results

3.1. Walkthrough Survey and Checklist

The collected data allowed obtaining crucial information to identify potential contamination sources from the indoor environment. Among the 13 optical shops, two (15.4%) were located inside a shopping mall; ten (76.9%) have daily cleaning intervention, and seven (53.8%) applied a broom as a cleaning measure. Moreover, it was found that an external company ensured indoor cleaning in four (30.8%) of the optical shops, and all of the health professionals confirmed that the optical equipment was disinfected with alcohol (with the exception made to pupilometers) between patients and hand-washing was ensured between patients in 11 (75.6%) optical shops. Only three shops (23.1%) have the HVAC system turned on and five (38.5%) did not have a washstand specific for the optometry office and all had manual opening.
There are no universal guidelines that apply to the decontamination of ophthalmic instruments. National disinfection protocols recommend the use of ethyl alcohol at 70% for surface disinfection, although this is a general recommendation for all health services. Additionally, there is no mandatory training for the health professionals working at optical shops, as this type of organization is not regulated as part of the health system in Portugal.

3.2. Fungal and Bacteria Load

Air fungal load in client/patient rooms ranged from 24 CFU/m3 to >500 CFU/m3 and in optometry offices from <1 CFU/m3 to >500 CFU/m3 (Figure 1). Eight of the 13 shops analysed were above the threshold recommended in the guidelines for fungal air load (>500 CFU/m3). In ten shops, the indoor fungal load was higher than the outdoors, surpassing the legal requirement (Figure 1).
On the surfaces it was estimated that the fungal load ranged from <1 CFU/m2 to 7 × 106 CFU/m2 in client/patient rooms and from <1 CFU/m2 to 5 × 106 CFU/m2 in optometry offices (not considering the overloaded samples). Ten from the 26 surfaces samples were overloaded (>500 CFU/m2) and impossible to count colonies (Figure 1).
Evidence of fungal contamination was also found in equipment samples. From the total of the equipment sampled, only three of the 13 shops showed no sign of fungal contamination.
Regarding the air bacteria load, concentrations ranging from 4 CFU/m3 to 324 CFU/m3 in clients/patients room and from 8 CFU/m3 to 276 CFU/m3 in optometry offices (Figure 2) were found. One of the thirteen shops analyzed was above the threshold detailed in the legal requirement for bacteria air load (indoor concentration should not exceed the outdoor concentration by 350 CFU/m3) (Figure 2). Concerning the surfaces, the bacterial counts indicated to be between 1 × 104 CFU/m2 to 2.24 × 106 CFU/m2 in clients/patients room and 1 × 104 CFU/m2 to 2.41 × 106 CFU/m2 in optometry offices from (Figure 2). The presence of bacteria was also detected in every piece of equipment sampled in all of the shops.

3.3. Fungal Identification

The fungal diversity present in the samples was characterized based on the morphological features of the colonies (Table 2). Indoor and outdoor air were very similar regarding the mycobiota present, since these samples were highly colonized by fungi belonging to the Alternaria, Cladosporium, and Penicillium genera. Overloaded plates with Chrysonilia sitophila isolates were also found in three of the 13 samples of indoor and outdoor air. Fourteen different fungi genera/sections/species were isolated in air, with Alternaria sp. being the most prevalent (54.3%), followed by Penicillium sp. (14.6%) and Cladosporium sp. (14.0%). In addition to the most prevalent and C. sitophila, other fungi were identified, such as, Talaromyces sp., Aureobasidium sp., Mucor sp., Geotrichum sp., Rhizopus sp., Acremonium sp. and Phoma sp. Among Aspergillus genus, sections Circumdati and Fumigati were found in low counts (Table 2).
The most prevalent fungi found in the surface samples were Aspergillus section Versicolores and Penicillium sp. (36.4%), followed by Aspergillus section Fumigati, Scytalidium hyalinum, and Cladosporium sp. (9.1%). The presence of overloaded plates with C. sitophila isolates was also verified on the surfaces, together with Phoma sp. and Rhizopus sp. (Table 2).
Aspergillus section Versicolores and Scytalidium hyalinum were only isolated on surfaces (Table 2).
On the ophthalmic equipment, the most prevalent fungi were Penicillium sp. (76.2%), Acremonium sp. (9.5%), and Rhizopus sp., Alternaria sp., and Cladosporium sp. (9.1% each). Five samples also revealed the presence of Chrysonilia sp. at a number of isolates impossible to count (Table 2).

3.4. Particulate Matter

As mentioned previously, results for two aerodynamic diameters were obtained (PM10 and PM2.5) (Figure 3). Results showed that clients waiting area had higher values for PM10 when compared with optometry office and outdoors (p > 0.05). For PM2.5, although with higher values, no statistically significant differences between samples were found.

3.5. Data Correlation Analysis

The correlation between microbiota assessment in air, and on surfaces and equipment is analysed in Table 3. Fungal load in air, and on surfaces and equipment presented moderate or strong positive correlation that could indicate that when fungal load in air increases, the same could occur on surfaces and equipment. A similar trend was observed in bacteria load assessment. However, a negative correlation (moderate to strong) between fungi and bacteria was found, suggesting that high fungal load is correlated with low bacteria load. According to the performed data analysis, fungi and bacteria were not correlated with the particulate matter assessment. However, a significant negative correlation was found between temperature and particulate matter concentration (PM2.5) (rs = −0.760; p = 0.011), air fungal load (Rs = −0.693; p = 0.026), and bacterial concentration on surfaces (rs = −0.778; p = 0.008). These results indicate that the higher the temperature, the lower the particulate matter concentration (PM2.5), air fungal load, and bacterial concentration on surfaces. Regarding the relative humidity no significant correlation was detected.
No statistically significant differences were detected in both fungal and bacteria contamination (air and surface) and particle size compared to the information obtained from the walkthrough survey and checklist.
Particulate matter assessment showed that an increase in a specific room could influence all of the other rooms of the optical shops with a similar increase.
The analysis between microbiota assessment and data obtained through the verification list, show a statistically significant difference, with optical shops that use a broom showing a higher fungal and bacteria load. No statistically significant differences were found between microbiota and particulate matter assessment and optical shops that presented a specific washstand and the ones that did not.

4. Discussion

Health professionals should ensure that their patients and staff are not exposed to infection risk while attending or working at their practice [13]. Optical shops must follow hygienic procedures to allow this specific environment presents adequate conditions for patient care. With a better understanding of the variables that influence the microbiota in optical shops effective control strategies can be established to reduce exposure risks of patients and, consequently, of vision health professionals [31].
It is suggested that indoor fungal levels should be compared with those found outdoors, since the first are dependent on the second [21,31,32]. Quantitative values of fungi were found to be equal (1/13) or higher (10/13) than outdoors in optical shops, suggesting fungal contamination sources from within and/or a concentration effect of fungi from outside to indoors. Additionally, in these shops there was no compliance with the national legal requirement and in seven of these 10, even with the previous legal requirements [21,22]. All of the overloaded plates were considered to have a higher load than 500 CFU/m3 due to health protection reasons.
Regarding the air bacteria load, most of optical shops indicated higher concentrations indoors than outdoors, suggesting bacterial sources from indoors, but only one store did not comply with the legal norms [21].
Air fungal identification was used to characterize the fungal burden present indoors, but also to verify the legal compliance. Aspergillus sections were isolated, namely Fumigati in two shops, and Circumdati in one shop, and in all situations surpassing the legal requirement of less than 12 CFU/m3. This value was set due to the toxigenic potential from both Aspergillus sections that are able to produce, among others, mycotoxins, gliotoxin, and ochratoxin A, already reported in different indoor environments [33]. These species may pose high clinical relevance and should not be underestimated, since they could constitute a major risk for health in humans and animals [34,35]. Moreover, according to the American Industrial Hygiene Association [36] in the Field Guide for the Determination of Biological Contaminants in Environmental Samples, the confirmed presence of the Aspergillus section Fumigati requires implementation of corrective measures.
Approximately 2–6% of the general population in developed countries is allergic to fungi and the higher sensitivity is detected with respect to genera of Alternaria, Cladosporium, Aspergillus, Penicillium, and Fusarium [37]. Two of these genera, Cladosporium and Penicillium, were found in all of the samples analysed in this study. Additionally, Alternaria (present in indoor and outdoor air samples) and Aspergillus (present in two optical shops) that were found in the present study are considered the most common allergens responsible allergic rhinitis and for 5–10% of asthma cases [37]. The results of the present study show that there is the need for public health intervention assuring the quality and safety of the rooms and equipment in optical shops that perform health interventions in patients.
Fungal load from surfaces present a higher range than in air samples, where the isolates were possible to count. In addition, Aspergillus section Versicolores and Scytalidium hyalinum were only isolated in surfaces and were not found in air. This result highlights the need to also collect samples from surfaces besides air in this setting, to ensure a more complete fungal contamination assessment [38].
In nine of the 13 trial frames assessed, the fungi species were identified, always being the equipment with higher fungal load in the analysed optical shops. Although all the health professionals confirmed that the disinfection of optical equipment was performed with alcohol (with the exception made to the pupilometer) between patients, the results do not comply with such disinfection. Trial frames regularly come into contact with patients during the refractive evaluation. The obtained results point out that disinfection is not done between every patient as reported or the disinfection procedures are not being done properly. This warrants further research to deepen the cleaning procedures and frequency of such cleaning.
The prevalence of fungal isolates are impossible to count with fast growing rates, such as Chrysonilia sitophila, Phoma sp., and Rhizopus sp., being among other drawbacks from classical-culture methods already reported [25], justifying the complementary use of molecular tools. Other studies already applied this strategy aiming to overcome conventional method limitations [38,39,40,41,42]. In addition to using conventional methods for fungi and bacteria applied to air samples that allows verification of legal compliance, analyses of surface samples applying molecular tools to target for specific indicators of harmful fungal and bacteria contamination in this specific environment should also be used. Fusarium sp. and Paecilomyces sp. [9,10,11,43] should be targeted due to reported clinical outcomes, being that the Fusarium genus is also a common contaminant of contact lens solution [44]. The Aspergillus genus should be also considered since it is broadly distributed in nature, with a large number of species frequently causing opportunistic infections and different clinical manifestations and diseases [45]. Among Aspergillus and considering not only their potential health effects, but also their environmental significance when detected indoors, the sections Fumigati [36,37,46,47,48], Flavi [36,37,46,48], Terrei [36,49], and Versicolores [35,36,48] should be adopted as indicators in optical shops.
The presence of the Aspergillus genus can also be harmful to the ocular system, as leukocyte defence is one of the ocular defence mechanisms that possess the ability to ingest and kill microorganisms. The absence of polymorphonuclear leukocytes is associated with fungemia with Candida, Aspergillus, and Fusarium spp. [50]. Eye trauma is the cause of fungal keratitis in temperate areas and the common fungal genera involved are Fusarium, Alternaria, and Aspergillus. The presence of Aspergillus in two optical shops is a public health concern, as Aspergillus species are the second most-common cause of fungal endophthalmitis [50].
In indoor air, humans and animals are assumed to be the main sources of bacterial aerosols, but these may also be created by disturbing previously-settled dust and in HVAC drainage systems [47]. Moreover, the building conditions, the level of occupation [51], and human activities are also responsible for bacterial concentrations [19,52,53]. Staphylococcus spp., besides, being reported as an infection agent following the introduction of soft lenses [4,6,7], is also abundant in indoor air [36,54]. Additionally, Pseudomonas is referred to as the most abundant and frequently-detected bacterium in the hospital context [55]. For future assessments, both genera could be regarded as potential bacterial indicators in optical shops.
Viable bioaerosol particles constitute a small percentage of the total concentration of microorganisms [56] and, therefore, a bias about microbiota in all optical shops assessed should be considered. To decrease the risk of infection several procedures of disinfection, sterilisation, and reprocessing should be made by eye care professionals. Cleaning of ophthalmic instruments is an essential prerequisite, as organic material (mucus, tears, skin, or make-up) may harbour infective organisms in dangerous concentrations and prevent adequate disinfection or sterilisation (insoluble deposits may require utilisation of isopropyl alcohol) [11].
Sampling the total air concentration of particulate matter only allows a simple estimate of exposure or indoor contamination that may not correlate with observed health effects [57]. The present study obtained data related with two aerodynamic diameters, allowing a more detailed risk assessment for patients and workers. Regarding particulate matter results, the client/patient waiting room showed higher contamination for both aerodynamic diameters. This fact is probably due to different aspects, namely a higher number of persons when compared with the optometry office promotes the transport and resuspension of particles to direct contact with the outdoors due to constantly open doors, and to an indoor lower dilution when compared with the outdoor environment [12]. This last aspect is also promoted by the lack of mechanical ventilation in the assessed optical shops. The importance of the mechanical ventilation to guarantee indoor air quality is well demonstrated in previous studies, particularly with particle contamination [58,59,60,61,62]. In the present study, the particulate matter assessment indicated that when these increase in a specific room all of the others rooms show the same tendency. This could be related to three different factors, specifically: there is no particle emission source in any specific location and, therefore, particles are coming, essentially, from the outdoors [12]. A previous study developed in Portugal already reported the influence of the outdoors in the contamination of indoor environments by nanoparticles [63]; particles are resuspended due to the movement of workers and patients [64,65,66]; and particles accumulate indoors because of the low ventilation rates, since there are no mechanical ventilation systems to guarantee dilution and dispersion [59,60,61,62,63]. Corroborating with our results, other authors reported no significant correlations between fungal and bacterial air load and PM concentrations, stating low concentrations of microorganisms associated with PM [67]. The attributed explanation was related to the influence of anthropogenic activities and atmospheric changes, and to the association of a large portion of bacteria with dust particles. Although fungi and bacteria correlated negatively, that could be due to competition reasons between microorganisms [68], and it was verified that fungi and bacteria air loads were influencing all of the other surface and equipment microbial concentrations. This situation supports the need to improve air quality, not only to comply with the legal requirements, but also to ensure proper hygienic conditions for this specific setting. Additionally, broom use, as in other health settings, should be avoided due to the increased contribution for fungal and bacteria contamination. This result reinforces that human activities, besides other factors, are important environmental variables that might influence microbial growth in hospitals [14] or other healthcare settings.
The negative correlation between temperature, air fungal load, and bacterial surface contamination was not consistent with what is expected, since a strict correlation between microbiota and temperature was already reported [69,70,71]. This may be justified by the effect of other environmental variables, such as workers and patients who may carry a great diversity of microorganisms [72], as well as the developed activities that may also affect fungal and bacterial load [71,73]. Regarding the negative correlation found between temperature and particulate matter, particularly PM2.5, it is important to mention that others aspects could influence the PM2.5 results, such as the number of occupants during the measurements and room size [74].
According to the data obtained, the high concentration of fungal and bacteria in air, on surfaces, and equipment sampled, must raise the awareness to the need of devising guidelines specific for this setting, since they can become an infection source. In addition, national legislation does not consider the occupants’ susceptibility, nor even the specificity of tasks that are developed in a specific environment, since the legislation is applied to several types of establishments, such as schools, offices, and hospitals, among others [40]. Considering this fact, the results should be compared with a more demanding threshold, such as the ones applied in hospital settings (200 CFU/m3) for fungi defined by Krzysztofik in 1992 [75]. Considering all of the data obtained, mechanical ventilation systems should be implemented in optical shops to avoid particulate matter entrance by open doors [58,59,60,61,62] and, consequently, deteriorate indoor air quality. Furthermore, microbiota data should be used to clearly define specific air quality guidelines for optical shops, and also procedures for surfaces and equipment cleaning. To the best of our knowledge, this is the first study developed in this specific setting and can be the first step towards a future protocol to ensure the proper microbiota and particle matter assessment in optical shops.

5. Conclusions

This work fills a gap providing information on the microbiota background and particulate matter in optical shops that provide contact lens services, and also their compliance with legal requirements. This study suggests the indicators that are representative of harmful fungal and bacterial contamination contributing to a future protocol to properly assess these pollutants. The confirmed presence of the Aspergillus section Fumigati requires implementation of corrective measures. Further investigations regarding sources of biological pollutants would be important to provide information to public health stakeholders.

Acknowledgments

Thanks are due to the orthoptists, other staff, and managers from optical shops who agreed to participate in this study. This study was supported by the Environment and Health Research Group from the Lisbon School of Health Technology. C2TN/IST authors gratefully acknowledge the FCT support through the UID/Multi/04349/2013 project. Authors do not have any financial support or relationships that may pose a conflict of interest.

Author Contributions

Carla Viegas and Sandra Cabo Verde conceived of and designed the experiments. Carla Viegas, Tiago Faria, Cátia Pacífico, Mateus dos Santos, and Ana Monteiro performed the experiments. Carla Viegas, Carla Lança, Susana Viegas, and Sandra Cabo Verde analyzed the data. Carla Viegas, Tiago Faria, Cátia Pacífico, Mateus dos Santos, Ana Monteiro, and Elisabete Carolino contributed with reagents, materials, and analysis tools. Carla Viegas wrote the paper.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Gyawali, R.; Nestha Mohamed, F.; Bist, J.; Kandel, H.; Marasini, S.; Khadka, J. Compliance and hygiene behaviour among soft contact lens wearers in the Maldives. Clin. Exp. Optom. 2014, 97, 43–47. [Google Scholar] [CrossRef] [PubMed]
  2. Stapleton, F.; Keay, L.; Jalbert, I.; Cole, N. The epidemiology of contact lens related infiltrates. Optom. Vis. Sci. 2007, 84, 257–272. [Google Scholar] [CrossRef] [PubMed]
  3. Morgan, P.B.; Efron, N.; Woods, C.A. An international survey of contact lens prescribing for presbyopia. Clin. Exp. Optom. 2011, 94, 87–92. [Google Scholar] [CrossRef] [PubMed]
  4. Nagachandrika, T.; Kumar, U.; Dumpati, S.; Chary, S.; Mandathara, P.S.; Rathi, V.M. Prevalence of contact lens related complications in a tertiary eye centre in India. Contact Lens Anterior Eye 2011, 34, 266–268. [Google Scholar] [CrossRef] [PubMed]
  5. Forister, J.F.Y.; Forister, E.F.; Yeung, K.K.; Ye, P.; Chung, M.Y.; Tsui, A.; Weissman, B.A. Prevalence of Contact Lens-Related Complications, UCLA Contact Lens Study. Eye Contact Lens 2009, 35, 176–180. [Google Scholar] [CrossRef] [PubMed]
  6. Szczotka-Flynn, L.B.; Pearlman, E.; Ghannoum, M. Microbial Contamination of Contact Lenses, Lens Care Solutions, and Their Accessories, A Literature Review. Eye Contact Lens Sci. Clin. Pract. 2010, 36, 116–129. [Google Scholar] [CrossRef] [PubMed]
  7. Eltis, M. Contact-lens-related microbial keratitis, case report and review. J. Optom. 2011, 4, 122–127. [Google Scholar] [CrossRef]
  8. Ng, A.S.Y.; Lau, W.W.Y.; Yu, D.K.H.; Wong, C.C.; Chan, C.W.N. Clinical Features and Outcomes of Fusarium Keratitis Associated with Contact Lens Wear. Eye Contact Lens 2008, 34, 113–116. [Google Scholar] [CrossRef] [PubMed]
  9. Khor, W.B.; Aung, T.; Saw, S.M.; Wong, T.Y.; Tambyah, P.A.; Tan, A.L.; Beuerman, R.; Lim, L.; Chan, W.K.; Heng, W.J.; et al. An outbreak of Fusarium keratitis associated with contact lens wear in Singapore. JAMA 2006, 295, 2867–2873. [Google Scholar] [CrossRef] [PubMed]
  10. Cohen, E.J. Fusarium Keratitis Associated With Soft Contact Lens Wear. Arch. Ophthalmol. Chic. 2006, 124, 1183. [Google Scholar] [CrossRef] [PubMed]
  11. Millner, P.D. Bioaerosols associated with animal production operations. Bioresour. Technol. 2009, 100, 5379–5385. [Google Scholar] [CrossRef] [PubMed]
  12. Schneider, T. Dust and fibers as a cause of indoor environment problems. SJWEH Suppl. 2008, 4, 10–17. [Google Scholar]
  13. Lakkis, C.; Lian, K.Y.; Napper, G.; Kiely, P.M. Infection control guidelines for optometrists. Clin. Exp. Optom. 2007, 90, 434–444. [Google Scholar] [CrossRef] [PubMed]
  14. Park, D.U.; Yeom, J.K.; Lee, W.J.; Lee, K.M. Assessment of the levels of airborne bacteria, gram-negative bacteria and fungi in hospital lobbies. Int. J. Environ. Res. Public Health 2013, 10, 541–555. [Google Scholar] [CrossRef] [PubMed]
  15. Scaltriti, S.; Cencetti, S.; Rovesti, S.; Marchesi, I.; Bargellini, A.; Borella, P. Risk factors for particulate and microbial contamination of air in operating theatres. J. Hosp. Infect. 2007, 66, 320–326. [Google Scholar] [CrossRef] [PubMed]
  16. Wan, G.H.; Chung, F.F.; Tang, C.S. Long-term surveillance of air quality in medical center operating rooms. Am. J. Infect. Control 2011, 39, 302–308. [Google Scholar] [CrossRef] [PubMed]
  17. Obbard, J.; Fang, L. Airborne concentrations of bacteria in a hospital environment in Singapore. Water Air Soil Pollut. 2003, 144, 333–341. [Google Scholar] [CrossRef]
  18. Klánová, K.; Hollerová, J. Hospital indoor environment, screening for micro-organisms and particulate matter. Indoor Built Environ. 2003, 12, 61–67. [Google Scholar] [CrossRef]
  19. Jürgensen, C.W.; Madsen, A.M. Influence of everyday activities and presence of people in common indoor environments on exposure to airborne fungi. AIMS Environ. Sci. 2016, 3, 77–95. [Google Scholar] [CrossRef]
  20. Gonçalves, P. Há menos Ópticas em Portugal. VER 2014, 26–27. [Google Scholar]
  21. Portaria, N. Requisitos de ventilação e qualidade do ar interior. Ministérios do Ambiente, Ordenamento do Território e Energia, da Saúde e da Solidariedade; Emprego e Segurança Social: Lisbon, Portugal, 2013. [Google Scholar]
  22. Decreto-Lei, N. Regulamento dos Sistemas Energéticos de Climatização em Edifícios (RSECE). Ministério das Obras Públicas; Transportes e Comunicações: Lisbon, Portugal, 2006. [Google Scholar]
  23. American Conference of Governmental Industrial Hygienists (ACGIH). Guidelines for the Assessment of Bioaerosols in the Indoor Environment; ACGIH: Cincinnati, OH, USA, 1989. [Google Scholar]
  24. Reynolds, S.J.; Streifel, A.J.; Mcjilton, C.E. Elevated airborne concentrations of fungi in residential and office environments. Am. Ind. Hyg. Assoc. J. 1990, 51, 601–604. [Google Scholar] [CrossRef]
  25. Viegas, C.; Almeida-Silva, M.; Gomes, A.Q.; Wolterbeek, H.T.; Almeida, S.M. Fungal Contamination Assessment in Portuguese Elderly Care Centers. Jpn. J. Toxicol. Environ. Health Part A Curr. Issues 2014, 77, 14–23. [Google Scholar] [CrossRef] [PubMed]
  26. Brown, J.S.; Gordon, T.; Price, O.; Ashgharian, B. Thoracic and respirable particle definitions for human health risk assessment. Part. Fibre Toxicol. 2013, 10, 12. [Google Scholar] [CrossRef] [PubMed]
  27. ISO 18593: 2004, Microbiology of Food and Animal Feeding Stuffs, Horizontal Methods for Sampling Techniques from Surfaces Using Contact Plates and Swabs; American National Standards Institute (ANSI): Washington, DC, USA, 2007.
  28. Hoog, D.C.; Guarro, J.; Gené, G.; Figueras, M. Atlas of Clinical Fungi, 2nd ed.; Centraalbureau voor Schimmelcultures: Utrecht, The Netherlands, 2002. [Google Scholar]
  29. Weijers, E.; Khlystov, A.Y.; Kos, G.P.A.; Erisman, J.W. Variability of particulate matter concentrations along roads and motorways determined by a moving measurement unit. Atmos. Environ. 2004, 38, 2993–3002. [Google Scholar] [CrossRef]
  30. Wichmann, H.E.; Spix, C.; Tuch, T.; Wolke, G.; Peters, A.; Heirinch, J.; Kreyling, W.G.; Heyder, J. Daily Mortality and Fine and Ultrafine Particles in Erfurt, Germany. Part I, Role or Particle Number and Particle Mass; Research Report 98; Health Effects Institute: Cambridge, MA, USA, 2000. [Google Scholar]
  31. Cabo Verde, S.; Almeida, S.M.; Matos, J.; Guerreiro, D.; Meneses, M.; Faria, T.; Botelho, D.; Santos, M.; Viegas, C. Microbiological assessment of indoor air quality at different hospital sites. Res. Microbiol. 2015, 166, 557–563. [Google Scholar] [CrossRef] [PubMed]
  32. Goyer, N.; Lavoie, J.; Lazure, L.; Marchand, G. Bioaerosols in the Workplace, Evaluation, Control and Prevention Guide; Institut de recherche Robert-Sauvé en santé et en Sécurité du travail: Montréal, QC, Canada, 2001. [Google Scholar]
  33. Environmental Mycology in Public Health, Fungi and Mycotoxins Risk Assessment and Management; Viegas, C.; Pinheiro, C.; Sabino, R.; Viegas, S.; Brandão, J.; Veríssimo, C. (Eds.) Academic Press: Cambridge, MA, USA, 2015. [Google Scholar]
  34. Fink-Grernmels, J. Mycotoxins, Their implications for human and animal health. Vet. Q. 1999, 21, 115–120. [Google Scholar] [CrossRef] [PubMed]
  35. Stevens, D.; Kan, V.L.; Judson, M.A.; Morrison, V.A.; Dummer, S.; Denning, D.W.; Bennett, J.E.; Walsh, T.J.; Patterson, T.F.; Pankey, G.A. Practice Guidelines for Diseases Caused by Aspergillus. Clin. Infect. Dis. 2000, 30, 696–709. [Google Scholar] [CrossRef] [PubMed]
  36. Dillon, H.K.; Heinsohn, P.A.; Miller, J.D. Field Guide for the Determination of Biological Contaminants in Environmental Samples; AIHA (American Industrial Hygiene Association) Biosafety Committee: Falls Church, VA, USA, 1996. [Google Scholar]
  37. Zukiewicz-Sobczak, W.A. The role of fungi in allergic diseases. Postep. Dermatol. I Alergol. 2013, 30, 42–45. [Google Scholar] [CrossRef] [PubMed]
  38. Viegas, C.; Faria, T.; dos Santos, M.; Carolino, E.; Sabino, R.; Quintal Gomes, A.; Viegas, S. Slaughterhouses Fungal Burden Assessment, A Contribution for the Pursuit of a Better Assessment Strategy. Int. J. Environ. Res. Public Health 2016, 13, 297. [Google Scholar] [CrossRef] [PubMed]
  39. Coenen, G.J.; Dahl, S.; Ebbehøj, N.; Ivens, U.; Stenbæk, E.; Würtz, H. Immunglobulins and peak expiratiory flow measurements in waste collectors in relation to bioaerosol exposure. Ann. Agric. Environ. 1997, 4, 75–80. [Google Scholar]
  40. Sabino, R.; Faisca, V.M.; Carolino, E.; Verissimo, C.; Viegas, C. Occupational exposure to Aspergillus by swine and poultry farm workers in Portugal. J. Toxicol. Environ. Health A 2012, 75, 1381–1391. [Google Scholar] [CrossRef] [PubMed]
  41. Rimac, D.; Macan, J.; Varnai, V.M.; Vucemilo, M.; Matkovic, K.; Prester, L.; Orct, T.; Trosic, I.; Pavicic, I. Exposure to poultry dust and health effects in poultry workers, Impact of mould and mite allergens. Int. Arch. Occup. Environ. Health 2010, 83, 9–19. [Google Scholar] [CrossRef] [PubMed]
  42. Viegas, C.; Malta-Vacas, J.; Sabino, R.; Viegas, S.; Veríssimo, C. Accessing indoor fungal contamination using conventional and molecular methods in Portuguese poultries. Environ. Monit. Assess. 2014, 186, 1951–1959. [Google Scholar] [CrossRef] [PubMed]
  43. Xiaoyong, Y.; Wjihelmus, K.R.; Matoba, A.Y.; Alexandrakis, G.; Miller, D.; Huang, A.J. Pathogenesis and Outcome of Paecilomyces Keratitis. Am. J. Ophthalmol. 2009, 147, 691–696. [Google Scholar]
  44. Chang, D.C.; Grant, G.B.; O’Donnell, K.; Wannemuehler, K.A.; Noble-Wang, J.; Rao, C.Y.; Jacobson, L.M.; Crowell, C.S.; Sneed, R.S.; Lewis, F.M.; et al. Multistate Outbreak of Fusarium Keratitis Associated With Use of a Contact Lens Solution. JAMA 2006, 296, 953–963. [Google Scholar] [CrossRef] [PubMed]
  45. Ramos, C.; Martínez, S.; Olivares, R. Gliotoxin production in 10 strains of Aspergillus fumigatus isolated from clinical cases’. Rev. Téc. Pecu. Méx. 2002, 40, 139–148. [Google Scholar]
  46. Viegas, C.; Sabino, R.; Botelho, D.; dos Santos, M.; Quintal Gomes, A. Assessment of exposure to the Penicillium glabrum complex in cork industry using complementing methods. Arh. Hig. Rada Toksikol. 2015, 66, 203–207. [Google Scholar] [CrossRef] [PubMed]
  47. Dagenais, T.; Keller, N. Pathogenesis of Aspergillus fumigatus in invasive aspergillosis. Clin. Microbiol. Rev. 2009, 22, 447–465. [Google Scholar] [CrossRef] [PubMed]
  48. McCormick, A.; Loeffler, L.; Ebel, F. Aspergillus fumigatus, contours of an opportunistic human pathogenic. Cell. Microbiol. 2010, 12, 1535–1543. [Google Scholar] [CrossRef] [PubMed]
  49. Hardin, B.D.; Kelman, B.J.; Saxon, A. Adverse Human Health Effects Associated with Molds in the Indoor Environment. J. Occup. Environ. Med. 2003, 45, 470–478. [Google Scholar] [PubMed]
  50. Klotz, S.A.; Penn, C.C.; Negvesky, G.J.; Butrus, S.I. Fungal and parasitic infections of the eye. Clin. Microbiol. Rev. 2000, 13, 662–685. [Google Scholar] [CrossRef] [PubMed]
  51. Maroni, M.; Seifert, B.; Lindvall, T. Indoor Air Quality a Comprehensive Reference Book; Elsevier: Amsterdam, The Netherlands, 1995. [Google Scholar]
  52. Nasir, Z.A.; Colbeck, I. Assessment of bacterial and fungal aerosol in different residential settings. Water Air Soil Pollut. 2010, 211, 367–377. [Google Scholar] [CrossRef]
  53. Zhu, H.; Phelan, P.E.; Duan, T.; Raupp, G.B.; Fernando, H.J.S.; Che, F. Experimental study of indoor and outdoor airborne bacterial concentrations in Tempe, Arizona, USA. Aerobiologia 2003, 19, 201–211. [Google Scholar] [CrossRef]
  54. Fang, Z.; Ouyang, Z.; Zheng, H.; Wang, X.; Hu, L. Culturable airborne bacteria in outdoor environments in Beijing, China. Microb. Ecol. 2007, 54, 487–496. [Google Scholar] [CrossRef] [PubMed]
  55. Flannigan, B. Indoor microbiological pollutants—Sources, species, characterization and evalution. Euro Courses Chem. Environ. Sci. 2013, 4, 73–98. [Google Scholar]
  56. Huang, P.Y.; Shi, Z.Y.; Chen, C.H.; Den, W.; Huang, W.M.; Tsai, J.J. Airborne and Surface-Bound Microbial Contamination in Two Intensive Care Units of a Medical Center in Central Taiwan. Aerosol Air Qual. Res. 2013, 13, 1060–1069. [Google Scholar] [CrossRef]
  57. Górny, R.L.; Harkawy, A.S.; Ławniczek-Wałczyk, A.; Karbowska-Berent, J.; Wlazło, A.; Niesler, A.; Gołofit-Szymczak, M.; Cyprowski, M. Exposure to Culturable and Total Microbiota in Cultural Heritage Conservation. Int. J. Occup. Med. Environ. Health 2016, 29, 255–275. [Google Scholar] [CrossRef] [PubMed]
  58. Holmberg, S.; Chen, Q. Air flow and particle control with different ventilation systems in a classroom. Indoor Air 2003, 13, 200–204. [Google Scholar] [CrossRef] [PubMed]
  59. Nij, E.T.; Hilhorst, S.; Spee, T.; Spierings, J.; Steffens, F.; Lumens, M.; Heederik, D. Dust control measures in the construction industry. Ann. Occup. Hyg. 2003, 47, 211–218. [Google Scholar]
  60. Spee, T.; Hoof, E.; Hoof, W.; Noy, D.; Kromhout, H. Exposure to wood dust among carpenters in the construction industry in the Netherlands. Ann. Occup. Hyg. 2007, 51, 241–248. [Google Scholar] [PubMed]
  61. Viegas, S.; Almeida-Silva, M.; Viegas, C. Occupational exposure to particulate matter in 2 Portuguese Waste-Sorting Units. Int. J. Occup. Med. Environ. Health 2014, 27, 854–862. [Google Scholar] [CrossRef] [PubMed]
  62. Almeida-Silva, M.; Wolterbeek, H.T.; Almeida, S.M. Elderly exposure to indoor air pollutants. Atmos. Environ. 2014, 85, 54–63. [Google Scholar] [CrossRef]
  63. Gomes, J.F.; Bordado, J.C.; Albuquerque, P.C. On the assessment of exposure to airborne ultrafine particles in urban environments. J. Toxicol. Environ. Health A 2012, 75, 1316–1329. [Google Scholar] [CrossRef] [PubMed]
  64. Goyal, R.; Khare, M. Indoor air quality modeling for PM10, PM2.5 and PM1.0 in naturally ventilated classrooms of an urban Indian school building. Environ. Monit. Assess. 2011, 176, 501–516. [Google Scholar] [CrossRef] [PubMed]
  65. Goyal, R.; Kumar, P. Indoor–outdoor concentrations of particulate matter in nine microenvironments of a mix-use commercial building in megacity Delhi. Air Qual. Atmos. Health 2013, 6, 747–757. [Google Scholar] [CrossRef]
  66. Luoma, M.; Batterman, S.A. Characterization of Particulate Emissions from Occupant Activities in Offices. Indoor Air 2001, 11, 35–48. [Google Scholar] [CrossRef] [PubMed]
  67. Alghamdi, M.A.; Shamy, M.; Redal, M.A.; Khoder, M.; Awad, A.H.; Elserougy, S. Microorganisms associated particulate matter, A preliminary study. Sci. Total Environ. 2014, 479–480, 109–116. [Google Scholar] [CrossRef] [PubMed]
  68. Mille-Lindblom, C.; Fischer, H.J.; Tranvik, L. Antagonism between bacteria and fungi, substrate competition and a possible tradeoff between fungal growth and tolerance towards bacteria. Oikos 2006, 113, 233–242. [Google Scholar] [CrossRef]
  69. Kim, K.; Park, J.; Kim, C.; Lee, K. Distribution of airborne fungi, particulate matter and carbon dioxide in Seoul Metropolitan Subway Stations. J. Prev. Med. Public Health 2006, 39, 325–330. [Google Scholar] [PubMed]
  70. Kakde, U.; Kakde, H.; Saoji, A. Seasonal Variation of Fungal Propagules in a Fruit Market Environment, Nagpur (India). Aerobiologia 2001, 17, 177–182. [Google Scholar] [CrossRef]
  71. Chmielowiec-Korzeniowska, A.; Tymczyna, L.; Drabik, A.; Krzosek, L. Microbial contamination level of air in animal waste utilization plants. Ann. Agric. Environ. Med. 2016, 23, 54–58. [Google Scholar] [CrossRef] [PubMed]
  72. Scheff, P.; Pulius, V.; Curtis, L.; Conroy, L. Indoor air quality in a middle school, Part II: Development of emission factors for particulate matter and bioaerosols. Appl. Occup. Environ. Hyg. 2000, 15, 835–842. [Google Scholar] [CrossRef] [PubMed]
  73. Buttner, M.; Stetzenbach, L. Monitoring Airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling. Appl. Environ. Microbiol. 1993, 59, 219–226. [Google Scholar] [PubMed]
  74. Cyrys, J.; Pitz, M.; Bischo, W.; Wichmann, E.; Heinrich, J. Relationship between indoor and outdoor levels of fine particle mass, particle number concentrations and black smoke under different ventilation conditions. J. Expo. Anal. Environ. Epidemiol. 2004, 14, 275–283. [Google Scholar] [CrossRef] [PubMed]
  75. Augustowska, M.; Dutkiewicz, J. Variability of airborne microflora in a hospital ward within a period of one year. Ann. Agric. Environ. Med. 2006, 13, 99–106. [Google Scholar] [PubMed]
Figure 1. Fungal load present in the air and on surfaces from the assessed optical shops.
Figure 1. Fungal load present in the air and on surfaces from the assessed optical shops.
Healthcare 05 00024 g001
Figure 2. Bacteria load present in air and on surfaces from the optical shops assessed.
Figure 2. Bacteria load present in air and on surfaces from the optical shops assessed.
Healthcare 05 00024 g002
Figure 3. PM results in the different clinic areas.
Figure 3. PM results in the different clinic areas.
Healthcare 05 00024 g003
Table 1. Sampling sites (air and surfaces) and equipment assessed.
Table 1. Sampling sites (air and surfaces) and equipment assessed.
AirSurfacesEquipment
Clients/patients waiting roomClients/patients waiting room floorTrial frames
Optometry officeOptometry office floorForopter
Outdoor (reference) Biomicroscope
Pupilometer
Automatic refractometer
Table 2. Fungal diversity present in the samples from the optical shops and respective prevalence (not considering the overloaded plates with the number of colonies impossible to count).
Table 2. Fungal diversity present in the samples from the optical shops and respective prevalence (not considering the overloaded plates with the number of colonies impossible to count).
SamplesFungi IdentificationPrevalence (n; %)
Indoor airAlternaria sp.788; 54.3
Penicillium sp.212; 14.6
Cladosporium sp.204; 14.0
Aureobasidium sp.92; 6.3
Others156; 10.7
Outdoor airAlternaria sp.832; 56.5
Cladosporium sp.432; 29.3
Penicillium sp.108; 7.3
Exophiala sp.36; 2.4
Others64; 4.4
SurfaceAspergillus section Versicolores40,000; 36.4
Penicillium sp.40,000; 36.4
Cladosporium sp.10,000; 9.1
Aspergillus section Fumigati10,000; 9.1
Scytalidium hyalinum10,000; 9.1
Ophthalmic equipmentPenicillium sp.16; 76.2
Acremonium sp.2; 9.5
Rhizopus sp.1; 4.8
Alternaria sp.1; 4.8
Cladosporium sp.1; 4.8
Table 3. Correlation between microbiota assessment in air, and on surfaces and equipment.
Table 3. Correlation between microbiota assessment in air, and on surfaces and equipment.
IIIIIIIVVVIIXXIXVXVI
I----------
II0.946 **---------
III−0.362−0.383--------
IV−0.323−0.5460.301-------
V−0.421−0.557 *0.581 *0.712 **------
VI−0.460−0.616 *0.5200.748 **0.892 **-----
VII−0.772 **−0.820 **0.2850.712 **0.4890.600 *----
VIII−0.418−0.605 *0.4550.941 **0.901 **0.865 **----
IX0.3420.410−0.581 *−0.554 *−0.745 **−0.637 *----
X0.581 *0.553−0.188−0.266−0.329−0.3010.583 *---
XI0.3880.442−0.447−0.557 *−0.682 *−0.606 *0.920 **---
XII0.0550.102−0.644 *−0.088−0.463−0.4640.638 *0.452--
XIII0.3070.413−0.734 *−0.571−0.747 **−0.647 *0.886 **0.822 **--
XIV0.0880.162−0.683 *−0.380−0.616 *−0.622 *0.592 *0.483--
XV−0.054−0.2000.0910.633 *0.1910.350−0.135−0.003--
XVI−0.056−0.126−0.0650.5520.1670.425−0.149−0.2190.710 **-
XVII0.013−0.0510.4870.3480.2630.463−0.248−0.1540.608 *0.595 *
XVIII0.043−0.0700.1310.5520.1410.353−0.121−0.0520.913 **0.857 **
XIX0.1390.029−0.0850.554 *0.1430.338−0.085−0.0580.874 **0.922 **
Legend: I—Clients/patients room surface fungal load; II—Total fungal load surface; III—Total fungal load equipment; IV—Clients/patients room air fungal load; V—Optometry office air fungal load; VI—Outdoor air fungal load; VII—Total air fungal load; VIII—Total indoor air fungal load; IX—Optometry office surface bacterial load; X—Clients/patients room surface bacterial load; XI—Surface total bacterial load; XII—Bacterial load Pupilometer; XIII—Bacterial load biomicrocospe; XIV—Equipment total bacterial load; XV—Clients/patients room air bacterial load; XVI—Optometry office air bacterial load; XVII—Outdoor bacterial air load; XVIII—Total air bacterial load; XIX—Total indoor air bacterial load; * Significant correlations at a 5% significance level; ** Significant correlations at a 1% significance level.

Share and Cite

MDPI and ACS Style

Viegas, C.; Faria, T.; Pacífico, C.; Dos Santos, M.; Monteiro, A.; Lança, C.; Carolino, E.; Viegas, S.; Cabo Verde, S. Microbiota and Particulate Matter Assessment in Portuguese Optical Shops Providing Contact Lens Services. Healthcare 2017, 5, 24. https://doi.org/10.3390/healthcare5020024

AMA Style

Viegas C, Faria T, Pacífico C, Dos Santos M, Monteiro A, Lança C, Carolino E, Viegas S, Cabo Verde S. Microbiota and Particulate Matter Assessment in Portuguese Optical Shops Providing Contact Lens Services. Healthcare. 2017; 5(2):24. https://doi.org/10.3390/healthcare5020024

Chicago/Turabian Style

Viegas, Carla, Tiago Faria, Cátia Pacífico, Mateus Dos Santos, Ana Monteiro, Carla Lança, Elisabete Carolino, Susana Viegas, and Sandra Cabo Verde. 2017. "Microbiota and Particulate Matter Assessment in Portuguese Optical Shops Providing Contact Lens Services" Healthcare 5, no. 2: 24. https://doi.org/10.3390/healthcare5020024

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop