Next Article in Journal
Study of Pressure Drop in Fixed Bed Reactor Using a Computational Fluid Dynamics (CFD) Code
Next Article in Special Issue
Study of Bubble Size, Void Fraction, and Mass Transport in a Bubble Column under High Amplitude Vibration
Previous Article in Journal / Special Issue
Hydrodynamics of Bubble Columns: Turbulence and Population Balance Model
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Two-Phase Bubble Columns: A Comprehensive Review

1
Politecnico di Milano, Department of Energy, Via Lambruschini 4a, 20156 Milano, Italy
2
Helmholtz-Zentrum Dresden-Rossendorf e. V. Institute of Fluid Dynamics, 01314 Dresden, Germany
*
Author to whom correspondence should be addressed.
ChemEngineering 2018, 2(2), 13; https://doi.org/10.3390/chemengineering2020013
Submission received: 15 January 2018 / Revised: 9 March 2018 / Accepted: 19 March 2018 / Published: 27 March 2018
(This article belongs to the Special Issue Bubble Column Fluid Dynamics)

Abstract

:
We present a comprehensive literature review on the two-phase bubble column; in this review we deeply analyze the flow regimes, the flow regime transitions, the local and global fluid dynamics parameters, and the mass transfer phenomena. First, we discuss the flow regimes, the flow regime transitions, the local and global fluid dynamics parameters, and the mass transfer. We also discuss how the operating parameters (i.e., pressure, temperature, and gas and liquid flow rates), the operating modes (i.e., the co-current, the counter-current and the batch modes), the liquid and gas phase properties, and the design parameters (i.e., gas sparger design, column diameter and aspect ratio) influence the flow regime transitions and the fluid dynamics parameters. Secondly, we present the experimental techniques for studying the global and local fluid dynamic properties. Finally, we present the modeling approaches to study the global and local bubble column fluid dynamics, and we outline the major issues to be solved in future studies.

1. Introduction

Bubble columns are multiphase reactors where the gas phase is dispersed into a continuous phase (e.g., a liquid phase in two-phase bubble columns or a suspension in slurry bubble columns) in the form of a “non-coalescence-induced” bubble or of “coalescence-induced” structures. In particular, two-phase bubble columns are widely used in petrochemical, biochemical and chemical industries owing to their advantages in both operation and system design (viz. the simple system layout) [1,2]. The simplest bubble column layout consists of a vertical cylinder without internals, in which the gas enters at the bottom—through a gas sparger (i.e., porous gas sparger, perforated plate, ring gas sparger, needle gas sparger or spider gas sparger, ref. [3]) and the liquid phase is supplied in batch mode or it may be led in either counter-currently or co-currently to the upward gas stream. Eventually, reactions between gas and liquid components may be observed in some practical cases (viz., hydrogenation oxidation, phosgenation, chlorination, alkylation, … [4]). Despite the simple system design, bubble columns are characterized by complex fluid dynamic interactions [5]. For this reason, their correct design and operation rely on the precise knowledge of the fluid dynamic phenomena on different scales: (i) “molecular-scale”, (ii) “bubble-scale”, (iii) “reactors-scale”, and (iv) “industrial-scale” (see Figure 1). At the “molecular-scale”, fundamental chemistry is required to study the interfacial phenomena, catalysts and gas conversion processes, and to formulate mass transfer models (e.g., for example, the film theory, the penetration theory, the surface renewal theory, the boundary layer theory; the reader may refer, for example, to Figure 2 for a simple representation of these phenomena). At the “bubble-scale”, experimental and theoretical works have proposed quantifying and understanding bubble size distributions (BSDs), bubble shapes, single bubble dynamics, “non-coalescence-induced” bubble dynamics and “coalescence-induced” behaviour as models of break-up and coalescence. At the “reactor-scale”, the flow patterns, mean residence time of the dispersed phase, dynamics of mesoscale clusters, liquid recirculation, and fluid back mixing have been studied. Of course, the phenomena at the bubble-scale” (i.e., the dispersed dynamics) influence the medium-scale circulation (i.e., turbulent eddies that transport the dispersed phase) and the large-scale circulation (i.e., the liquid phase flowing downward in the region near the wall and upward in the center of the column), which characterize the “reactor-scale”. Finally, scale-up methods are applied to estimate the fluid dynamics of “industrial-scale” reactors based on the laboratory-scale experimental facilities.
This review mainly focuses on the “bubble-scale” and the “reactor-scale” and aims to provide insights into the bubble column fluid dynamics, to support methods and criteria for scaling-up proposals. In addition, the “molecular-scale” is briefly discussed to provide insight and a brief overview of the mass transfer phenomena and modeling approaches. It is worth noting that the knowledge of fluid dynamics at the “bubble-scale” and at the “reactor-scale” can be quantified through the precise estimation of the local fluid dynamic properties (viz., the bubble aspect ratio, the bubble rising velocity, the bubble size distributions, …) and the global fluid dynamic properties (viz., ɛG, the mean bubble residence time, …) fluid dynamic properties. In this respect, the correct quantification and estimation of these fluid dynamics parameters is very important for avoiding overestimations of investment costs (i.e., with respect to the downstream processing units and to the reactor itself) and design failures. The review is structured as follows: In Section 2, we discuss how the operating parameters, operating modes, liquid and gas phase properties, and design parameters influence the flow regime transitions and the fluid dynamics parameters. In Section 3, we present the experimental techniques to study the “bubble-scale” and the “reactor-scale” fluid dynamic properties. In Section 4, we present modeling approaches to study the “bubble-scale” and the “reactor-scale” bubble column fluid dynamics.

2. Bubble Column Fluid-Dynamics

In this section, the flow regimes, flow regime transitions, gas hold-up, bubble size distributions and shapes, local flow properties and mass transfer phenomena are discussed. We also discuss how the operating parameters (i.e., the operating pressure, pc, the operating temperature, Tc, and the superficial velocities, UG and UL), operating modes (i.e., the co-current, the counter-current and the batch modes), liquid and gas phase properties (i.e., liquid viscosity, μL, the gas density, ρG, the presence of active agents, …), and design parameters (i.e., the gas sparger design, the column diameter, dc, and the aspect ratio, AR influence the flow regime transitions and the global and local fluid dynamics parameters(it is worth noting that the correct definition of AR relies on the initial liquid level (AR = H0/dc), rather the column height, Hc, as discussed by Sasaki et al. [6]). It is worth noting that the proposed discussion considers an air-water bubble column operating at ambient conditions as the “baseline” case; thus, the variations owing to the design and operation parameters are discussed starting from this the “baseline” case.

2.1. The Flow Regimes and the Flow Regime Tranistions in Bubble Columns

In the next sections, the prevailing flow regimes are described and subsequently, the relationships between the boundaries of the different flow regime transitions and the different parameters of the systems are described.

2.1.1. The Flow Regimes in Bubble Columns

The coupling between the gas and the liquid phases physically manifest in the flow regimes. Based on the previous literature as well as our experimental investigations, in the current authors’ opinion, a change in the design parameters of bubble columns and a change in the phase properties affect the transition points between the flow regimes and do not influence the properties and main characteristics of the flow regimes themselves. Indeed, when the system design parameters or the phase properties are changed, the boundaries between the flow regimes change as a consequence. In particular, when considering the most general case, five flow regimes (and the flow regime transitions in-between) may be observed when increasing the gas flow rate (e.g., the superficial gas velocity, UG) using a fixed system design and phase properties: (i) the mono-dispersed homogeneous flow regime; (ii) the pseudo-homogeneous flow regime; (iii) the transition flow regime; (iv) the heterogeneous flow regime; (v) the slug flow regime; and (vi) the annular flow regimes. The first flow regime observed is the “mono-dispersed homogeneous” flow regime, which is characterized by mono-dispersed BSDs, according to the change in the sign of the lift force coefficient (see ref. [7,8,9,10,11,12]); an example of this flow regime is the one observed by Mudde et al. [13], in which a “fine” gas sparger was used, or by Besagni et al. [14]. When increasing UG, the BSDs shift towards higher bubble diameters (according to the change in the sign of the lift force coefficient, and, thus, the “pseudo-homogeneous” homogeneous flow regime is observed; of course, if large bubbles are aerated [7] by using a “coarse” gas sparger, the lower boundary of the former flow regime moves towards a low UG and eventually, disappears. Generally speaking, the mono-dispersed and poly-dispersed BSDs are characterized by limited interactions between the bubbles and only “non-coalescence-induced” bubbles exist, as defined and observed by [7]. In general, one may refer to the homogeneous flow regime as the complete range of both mono-dispersed and pseudo-homogeneous flow regimes. With an increase in UG, the number of bubbles having a negative lift force coefficient increases and these continue migrating towards the center of the bubble column; at a certain point, the rate of this process leads to the formation of “coalescence-induced” bubbles [7] (as demonstrated by Besagni et al. [11,12]) when “coalescing” solutions are employed. Conversely, if “non-coalescing” solutions are employed, the transition flow regime is identified by the appearance of “clusters of bubbles”, as defined in refs. [15,16] and observed by [7]. The flow regime transitions from the homogeneous flow regime towards the transition flow regime concept are displayed in Figure 3.
Beinhauer [17] found that the first “coalescence induced” bubble appeared at about UG = 0.02 m/s and, by increasing the gas flow rate, both “non-coalescence-induced” and “coalescence induced” bubbles increased until the non-coalescence-induced” bubbles reached a maximum, and then decreased toward a constant value. Conversely, Scumbe and Grund [18], Krishna et al. [19,20] and Besagni et al. [7] reported that the non-coalescence-induced” bubbles increase until the flow regime transition, and then only “coalescence induced” bubbles increase. The difference is probably caused by the different gas sparger design (“fine-gas sparger” and “coarse-gas sparger”). At higher UG, the heterogeneous flow regime is achieved. This flow regime is associated with high coalescence and breakage rates and a wide variety of bubble sizes; in the heterogeneous flow regime, the liquid phase flows in an oscillatory manner, upwards and downwards, because the UG is not high enough to carry the liquid continuously upward. The reader should refer to the recent review proposed by Montoya et al. [21] for a complete discussion on this flow regime. When UG is increased, the slug flow regime may occur; however, in industrial applications, this flow regime is not observed, owing to Rayleigh–Taylor instabilities [22] which arise because of the large diameter effects. The quantification of Rayleigh–Taylor instabilities at the “reactor-scale” is quantified through the dimensionless diameter, D*H:
D H = D H σ / g ( ρ L ρ G )
In Equation (1), DH is the hydraulic diameter, dc is the bubble column (inner) diameter, σ is the surface tension, g is the acceleration due to gravity and ρLρG is the density difference between the two phases. Bubble columns with D*H greater than the critical value, D*H,cr = 52 [23]—dc ≳ 0.13–0.15 m (at ambient temperature and pressure, as a circular bubble column)—are considered to be large diameter bubble columns. When D*c > D*H,cr, the cap bubbles can no longer be sustained, and “coalescence-induced” bubbles (or, cluster of bubbles) appear instead of the slug flow regime. At very high UG, the annular flow regime may occur; this is characterized by a high-speed gas core containing entrained liquid droplets. Generally, this flow regime cannot be observed in industrial-scale reactors because the gas velocity requested is too high. In practical applications (i.e., in industrial applications), large-diameter and large-scale bubble columns are used. In addition, in these applications, the slug and annular flows are not observed (see the air-water flow regime maps in ref. [24]; this flow map is very important as it describes the relationships between the flow regimes and the bubble column diameter, which is related to Rayleigh–Taylor instabilities).

2.1.2. The Flow Regime Transitions

The flow regime transitions between the above-mentioned flow regimes depend on the operation mode, the design parameters of the bubble column and the properties of the gas/liquid phases. In “large-diameter” air-water bubble columns with a “coarse gas-sparger”—operating at ambient temperature and pressure—the homogeneous flow regime ends at approximately UG,trans ≈ 0.02–0.04 m/s [25]. Depending on the many variables characterizing the system, UG,trans either reduces (“homogeneous flow regime destabilization”) or increases (“homogeneous flow regime stabilization”). In the following sections, the influence of the operating parameters, operating modes, liquid and gas phase properties, and design parameters on the flow regime transitions are discussed
When considering the proposed discussion, the reader should take into account that three main transitions exist in large diameter bubble columns: (a) the transition between the “mono-dispersed” homogeneous and the pseudo-homogeneous flow regimes; (b) the transition between the pseudo-homogeneous flow regime and the transition flow regime; (c) the transition between the transition flow regime and the heterogeneous flow regime. In the literature, the first regime transition is often not considered, and in practical cases, just the second and third regime transitions are evaluated. In addition, many authors refer to just the second flow regime transition, without any reference to the third one, except for a limited number of studies [26,27,28]. In the following sections, for the sake of clearness, we refer (except where stated differently) to the “flow regime transition point” as the second flow regime transition (viz. the end of the homogenous flow regime). In future studies, a mathematical model for computing all flow regime transitions displayed in Figure 3 is needed.

Influence of the Bubble Column Design

Column diameter. It is not clear whether the increase in dc stabilizes [29,30] or destabilizes [8,31,32,33] the homogeneous flow regime. Sarrafi et al. [29] (dc = 0.08–0.155 m—also taking data from the literature), Ohki and Inoue [30] (dc = 0.04–0.16 m and Hc = 2.0–3.0 m) and Urseanu [19] (dc = 0.051–0.63 m, Hc = 2.0–4.0 m) found that an increase in dc, increased UG,trans. Sarrafi et al. [29] also reported that, for dc > 0.15 m, UG,trans does not depend on dc. Conversely, Ruzicka et al. [31] (dc = 0.14, 0.29 and 0.4 m, Hc = 0.1–1.2 m) and Zahradnik et al. [8] (dc = 0.14, 0.15, and 0.29, Hc = 0.25–1.5 m) found that an increase in dc reduced UG,trans. Al-Oufi et al. [32,33] observed that the annular gap layout destabilizes the homogenous flow regime. Conversely, Besagni et al. [34] found that the annular gap layout stabilized the homogeneous flow regime, possibly because of the gas sparger in the open tube configuration. In the current authors’ opinion, the influence of the bubble column diameter is related to Rayleigh–Taylor instabilities [22], as previously discussed.
Aspect ratio. In low-AR bubble columns, the flow circulation patterns are not completely developed, and thus, the end-effects (i.e., top column effects and near gas sparger) are more relevant; in particular, the gas sparger effects tend to destabilize the homogeneous flow regime in low-AR bubble columns, for example, Xue et al. [35] observed a strong influence of the gas sparger parameters in local void fractions up to AR = 5. Thorat and Joshi (dc = 0.385 m, Hc = 0.385–3.08 m) and Ruzicka et al. [31] observed that an increase in AR destabilized the homogeneous flow regime. Sarrafi et al. [29] observed no effect beyond 4 m. Of course, these results are related to the evalution of the BSDs inside the bubble columns [36]. Besagni et al. [37] found that, when using a “coarse-gas sparger”, an increase in AR destabilized the homogeneous flow regime up to a critical value equal to approximately 5 in batch mode (Figure 2) and 10 in counter-current mode (Figure 3). Figure 4 summarizes the main results from the literature concerning the influence of the aspect ratio on the flow regime transitions; Figure 4 considers both (a) the regime transition between the pseuso-homoegenous flow regime and the transition flow regime and (b) the regime transition between the transition flow regime and the heterogeneous flow regime.
Gas sparger design. It is known that the gas sparger design highly influences the flow regime transitions in bubble column. Generally, gas spargers with a hole diameter, d0, smaller than 1 mm (the “fine distributors”, i.e., porous [32,33,38,39], membrane [40], needles [13,14,41] or sieve tray/perforated plates with small openings [37] see Figure 5 for a representation of these gas spargers) can maintain a stable mono-dispersed homogenous flow regime also at a high UG; hence, the homogeneous flow regime is stabilized [13] because the “mono-dispersed homogeneous” flow regime exists [37] and the “pseudo-homogeneous” flow regime takes place after the former is destabilized. In contrast, using a “coarse gas sparger” (d0 > 1 mm—see Figure 6 for a representation of these gas spargers) the “mono-dispersed homogeneous” flow regime may not exist and a “pseudo-homogeneous” flow regime may be observed at lower gas superficial velocities; finally, when using a “very coarse gas sparger” (d0 >> 1 mm), the homogeneous flow regime may not be established and the transitional/heterogeneous flow regime may take place [42]. A well-designed “fine distributor” may stabilize the homogeneous flow regime far beyond expectations, as demonstrated by Mudde et al. [13]. An early study was conducted by Zahradnik [43], demonstrating that, in perforated plates, the smaller the gas sparger opening, the more the homogeneous flow regime is stabilized. Sarrafi et al. [29] found that the transition velocity decreases as d0 increases, up to a value of d0 = 0.0015 m. Thorat and Joshi [44] found that the homogeneous flow regime is stabilized with a decrease in dhole (d0 = 0.0008–0.05 m). It is also worth noting that they observed that an increase in AR destabilized the homogeneous flow regime. Sal et al. [45] found that UG,trans decreases while increasing the gas sparger openings (d0 = 0.001–0.003 m). Besagni et al. [46] compared two different “coarse-gas spargers” and found no significant differences between them; conversely, in more recent studies, Besagni et al. [14,37] compared the flow regime transitions in both “coarse-gas spargers” and “fine-gas spargers” (a needle gas sparger [14] or a perforated gas sparger [37]); they found that a uniform bubble bed stabilized the homogeneous flow regime, owing to the presence of the monodispersed homogenous flow regime.

Influence of the Bubble Column Operation Mode

Akita and Yoshida [47] (dc = 0.152 m, Hc = 2.5 m) observed that the superficial liquid velocity (UL up to 0.04 m/s) had no influence in both the counter-current and the co-current modes. Jin et al. [48] (dc = 0.160 m, Hc = 2.5 m) reported that the transition point is approximately the same for the three working modes if UL < 0.04 m/s, whereas, for higher UL (in co-current and counter-current modes), the transition velocity decreases when the UL increases. Otake et al. [49] (dc = 0.05 m, Hc = 1.5 m) observed earlier flow regime transitions with an increased liquid flow rate in counter-current operations (UL up to −0.15 m/s). A similar conclusion was also drawn by Yamaguchi and Yamazaki [50] (dc = 0.04 m and 0.08 m). Extensive studies on the influence of the liquid velocity in the counter-current mode were performed by Besagni et al. [28,34,46,51,52,53,54], who found that the counter-current mode destabilized the homogeneous regime in all of the different configurations studied (viz. the pipe sparger in the annular gap and in the open tube configuration [34] and the spider sparger [46]). Figure 7 and Figure 8 summarize the main experimental results obtained by Besagni et al. [28,34,46,51,52,53,54]. Recently, Trivedi et al. [55] performed a detailed study on the hydrodynamics of counter-current bubble columns and found results in agreement with Besagni and co-authors. It is worth noting that Besagni et al. [28] also studied the influence of the bubble column aspect ratio in the counter-current mode; the results of this study are presented in Figure 8, where it can be observed that an increase in AR destabilized the homogeneous flow regime up to a critical value, equal to approximately 5 in batch mode (Figure 2) and 10 in counter-current mode (Figure 3). Further explanation for this effect is provided in Section 2.2, when discussing the influence of the operation mode on the gas hold-up.

Influence of the Liquid Phase Viscosity

The homogeneous flow regime may be either stabilized or destabilized depending on the liquid phase viscosity. This behavior was interpreted by Besagni and co-authors using the “dual effect of viscosity over the flow regime transition” [11] concept: (a) “moderate/high viscosities” stabilize the homogeneous flow regime, owing to increased coalescence [3,11,56] and the presence of cap-bubbles [11] (as experimentally observed by Wikinson et al. [56] and more recently, by Yang et al. [57]); (b) “low viscosities” stabilize the homogeneous flow regime, as the reduced coalescence increases the number of small bubbles; For example, Besagni et al. [11] (Figure 9a,b) found that μL, depending on its value, either stabilizes or destabilizes the homogeneous flow regime compared to air-water systems (The Mono-Ethylene Glycol, MEG, concentration, cMEG = 0%: UG,trans = 0.0264 m/s, εG,trans = 0.09; cMEG = 5%: UG,trans = 0.039 m/s, εG,trans = 0.18; cMEG = 80%: UG,trans = 0.023 m/s, εG,trans = 0.07). It is worth noting that the increased coalescence may also suppress the homogeneous flow regime and, for μL > 8 mPa·s, it may not exist even with a ‘fine gas sparger’ [8,58,59,60].
In this respect, Besagni et al. [14] observed that an increase in the liquid phase viscosity has an effect that can be approximated as the influence of an increase in the gas sparger opening—this conclusion suggests that these two effects contribute to a shift in the boundaries of the mono-dispersed homogenous flow regime to very low gas flow rates (Figure 9c,d). Ruzicka et al. [60] observed that the homogeneous flow regime is stabilized at low μL values (μL = 1–3 mPa·s) and that UG,trans increases with μL in this range, whereas it decreases at moderate μL values (μL = 3–22 mPa·s). Olivieri et al. [61] observed a stabilization of the homogeneous flow regime up to μL = 4.25 mPa·s, and then for higher μL, a destabilization of the homogeneous flow regime. Finally, the above-mentioned results were also confirmed by ultrafast X-ray tomography investigations [62] (dc = 0.07 m, Hc = 1.5 m, orifice gas sparger, d0 = 1 mm). In this study, it was observed that, beyond μL = 5.18–8.95 mPa·s, the homogeneous flow regime is no longer observed. It is worth noting that, in these systems, a non-Newtonian fluid behavior may exist; in this respect, we propose some speculations based on the conclusions of Olivieri et al. [61]; they interpreted the stabilization of the homogeneous flow regime as the relaxation time by considering the negative wake phenomena occurring in the rear of a bubble in the case of viscoelastic fluids. Please refer to Besagni et al. [11] for further discussion concerning this point.

Influence of the Active Compounds: Inorganic Compounds (“positive surfactants”)

Inorganic compounds (i.e., electrolyte solutions) are attracted to the interface where they adsorb positively, lower the surface tension, cause coalescence suppression and, finally, stabilize the homogeneous flow regime [63,64,65,66,67,68]. Indeed, it is known that most electrolytes inhibit bubble coalescence in pure liquid phases [63,64,65,66,67,68] and, as a consequence, the homogeneous flow regime is stabilized [69,70]. For example, owing to their influence, the prevailing flow regime may change from heterogeneous to homogeneous, due to surfactant addition [71] as the boundary between the flow regimes changes. In this respect, the transition molar concentration, ct, is defined as the concentration, c, of the non-coalescent media above which bubble coalescence is drastically reduced. Depending on the concentration, n, we can define a “coalescent regime” (n* ≤ 1) and a “non-coalescent regime” (n* > 1), through the dimensionless concentration, n*—following the formulation of nt, proposed by Prince and Blanch [72] (a modified version of the formulation of Marrucci [63]):
n = c c t ( Prince   and   Blanch ,   1990 ) c / { 1.18 μ L ρ L ( B σ r b ) 0.5 R g T ( σ n ) 2 }
where B is the retarded Hamaker constant (B = 1.5 × 10−28 J m), Rg is the gas constant, T is the temperature of the system, rb is the bubble radius, and σ and ∂σ/∂n are the surface tension and the surface tension gradient with electrolyte concentration, respectively. This concentration has been found to be unique for each salt [73], valid for a swarm of bubbles and does not depend on UG [66,74]. Some of the relevant studies from the existing literature are here summarized, i.e., Besagni et al. [75] (dc = 0.24 m, H0 = 3.0 m; kitchen quality NaCl—Figure 6a,b), Thorat and Joshi [44] (dc = 0.385 m, Hc = 0.385–3.08 m, NaCl), Ribeiro and Mewes [76] (dc = 0.12 m, Hc = 1.25 m, NaCl, Na2SO4, NaI), Kelkar et al. [77] (dc = 0.154 m, HC = 3.25 m), Grover et al. [78] (dc = 0.1 m, HC = 1.5 m. NaCl and CuCl2), Rucizka et al. [70] (dc = 0.14 m, H0 = 0.4 m; CaCl2), Orvalho et al. [69] (dc = 0.14 m, H0 = 0.4 m; Na2SO4, NaCl and kitchen quality NaCl). It is worth nothing that Rucizka et al. [70] and Orvalho et al. [69] observed a dual effect of the electrolyte concentration on the flow regime transitions. Figure 9a,b display the influence of NaCl concentration on the flow regime transition points; conversely, Figure 10a,b display the influence of AR and n* on the flow regime transition points, supporting the above-mentioned discussion on the influence of the concentration of the inorganic substances in the “coalescent regime” (n* ≤ 1) and the “non-coalescent regime” (n* > 1).

Influence of the Active Compounds: Organic Compounds (“negative surfactants”)

The organic substances (i.e., alcoholic solutions) are repelled from the bubble interface where they adsorb negatively, cause small increase of the surface tension and, finally, inhibit the coalescence [79,80]: the alcohol molecules are composed by hydrophobic and hydrophilic parts that are adsorbed at the interface when dissolved in water, causing the coalescence suppression [81]. Among the literature, some of the relevant studies are here summarized, i.e., Krishna et al [19,20,82] (dc = 0.1, 0.15 and 0.38 m, Hc = 4 m, EtOH up to 1%vol), Al-Oufi et al. [32] (dc = 0.102 m, Hc = 2.25 m, EtOH up to 300 ppmwt), Dargar et al. [83] (dc = 0.127 m, Hc = 2.75 m, EtOH up to 5%wt) and Besagni et al. [7] (dc = 0.24 m, H0 = 3.0 m; 0.05%wtFigure 6a,b). Figure 9a,b display the influence of EtOH concentration on the flow regime transition points; conversely, Figure 11a,b display the influence of AR and EtOH concentration on flow regime transition points.

Pressure and Temperature

An increase in pressure stabilizes the homogeneous flow regime [2,20,56,84,85,86,87,88,89,90,91,92,93,94,95,96]. Indeed, increasing the pressure increases the break-up rate and reduces the coalescence rate: the new equilibrium between coalescence/break-up leads to a decrease in the bubble size and delays the appearance of large bubbles. The cause is the propagation of Kevin–Helmholtz instability and internal gas circulation, as stated in refs. [91,97]. In particular, Kitscha and Mustafaogullari [22] applied this instability to model the break-up phenomena in bubble columns operated at high pressures. It is worth noting that the Kelvin–Helmholtz instability can be classified as a surface instability and, thus, it is somewhat similar to the above-mentioned Rayleigh–Taylor instability, discussed in Equation (1). The main difference between these two instabilities concerns the relative velocities between the phases: the Kelvin–Helmholtz instability allows a relative velocity between the phases. Based on the Kelvin–Helmholtz instability, Wilkison and Van Dierendonck [98] proposed a maximum stable bubble size, in which all the disturbances in the liquid phase with a wavelength larger than the critical wavelength may break up a bubble. The interested reader may also refer to the discussion proposed by Lott et al. [99] concerning this instability. Also, the temperature seems to have a stabilizing effect over the homogeneous flow regime [78,100,101] due to the formation of small bubbles [1,2,101,102]. The combined effect of pressure and temperature was studied by Lin et al. [101] (pc = 0.1–15.2 MPa, Tc = 298–350 K) showing a stabilization of the homogeneous flow regime; it can be stated that many industrial processes may be run in the pseudo-homogeneous flow regimes. Generally, at high pressures and temperatures and for pc > 10 MPa, the flow regime transition is mainly governed by the temperature, properties of the liquid phase, liquid velocity and gas sparger design [1].

2.1.3. The Flow Regime Maps

The flow maps help in predicting the prevailing flow regime based on the operating conditions and column geometry. An example is displayed in Figure 12. Lots of flow maps have been proposed for two-phase flows in large and small diameter pipes, and the most common map for a bubble column was proposed by Shah [24] (Figure 12a).
This map—limited to low viscosity systems in ambient conditions—presents the prevailing flow regimes (homogeneous, transitional flow and heterogeneous) based on the column diameter and superficial gas velocity. Conversely the flow maps produced by Zhang et al. [103], which also apply to air-water systems in ambient conditions, are limited to small-diameter columns but take into account both the gas and the liquid superficial velocities. The interested reader may also refer to the review by Wu et al. [104] for a comprehensive discussion on flow regime maps in vertical pipes and annuli. In the current authors’ perspective, a general flow regime map is still missing; future studies should be devoted to proposing a comprehensive flow regime map based on the discussion of the flow regime transitions proposed in Section 2.2.1 and Figure 3.

2.2. The Gas Hold-Up

The gas hold-up, εG, determines the residence time and, in combination with the BSD, the interfacial area (related to the reactor size); it is related to the column design, operation, phase properties and operating conditions. It is worth noting that, generally, the homogeneous flow regime is more sensitive than the heterogeneous flow regime to the operating parameters.

2.2.1. Influence of the Bubble Column Operation

Superficial Gas Velocity and Gas Holdup Curve Structure

It is known that the gas hold-up curve (the relation between ɛG and UG) summarizes the complexity of the bubble column fluid dynamics, from the “bubble-scale” to the “reactor-scale” (see, for example, the discussion in ref. [69], Section 3.2). For example, “coarse gas spargers” lead to monotonic gas hold-up curves (Figure 13a), whereas, when using “fine gas spargers”, a peak in the gas hold-up curve can appear (Figure 13b) owing to the mono-dispersed bubble size distribution, which leads to the hindrance effect (related to the Ledinegg instability) that is physically manifested by a peak on the gas hold-up curve, leading to a reversed S-shaped curve, as discussed and commented on in refs. [14,37] and displayed in Figure 3b.
Given the mass conservation to the gas phase, the gas hold-up is given by ɛG = (UG/Uswarm); theoretically, if the bubbles travel at their terminal velocity, ɛG will increase linearly with the gas flow rate. However, the coupling between the phases causes deviations from linearity (see ref. [60]). In the homogeneous flow regime, the hindrance reduces the bubble velocity, thus increasing ɛG, whereas in the transition flow regime the “coalescence-induced” bubbles result in a decrease in ɛG and cause ɛG to decrease proportionally less than UG [34]. The presence of “non-coalescence induced” and “coalescence induced” bubbles has been investigated by different authors (i.e., [17,18,19,46]). For the sake of clarity, Figure 14 and Figure 15 provide a comparison of gas hold-up curves from different studies proposed in the literature and summarized in Table 1 and Table 2.

Superficial Liquid Velocity

Bubble columns may run batchwise (or, with UL < 0.01 m/s), in co-current or in counter-current mode [1,2,3]. Low liquid velocities generally do not affect ɛG—as found by several investigators [24,47,113,114,115,116,117,118,119]—because, if UL is low compared to the bubble rise velocities, the acceleration of the bubbles (caused by the non-stagnant operation) will be negligible [120]. For example, Akita and Yoshida [47] reported a negligible effect of liquid velocities up to 0.04 m/s, either in gas–liquid counter-current or con-current operations. Of course, at higher liquid velocities, the column operation influences ɛG; it is generally admitted that co-current operation tends to reduce ɛG and counter-current operation increases ɛG, as bubbles are either accelerated or decelerated by liquid motion [1,114]. Baawain et al. [121], showed that the counter-current or co-current operating mode influenced ɛG for about 5% of its weight, and less than 1% of its bubble size, showing that the effect observed is mainly caused by the bubble rise velocity and not only caused by the bubble size. In agreement with this explanation concerning the influence of UL on bubble motion, different studies have reported ɛG decreasing in co-current operations [49,90,122,123,124,125,126,127,128] and increasing in counter-current operations [48,49,128]. Biń et al. [128] compared the three-operation mode showing that ɛG increases with UL in counter-current mode and decreases or remains constant in co-current mode. The effect is more pronounced at a high gas velocity and the difference in ɛG between co-current and counter-current modes is around 10%. The same trends were observed by Jin et al. [48], with a maximum difference of 2% between counter-counter and co-current operations and it was found that the influence of working mode is lower at high ɛG. Similar trends were found by Otake et al. [49], as already discussed when considering the flow regime transition. Besagni et al. [34,46,51,52,53,54] found that when increasing the liquid flowrate, a faster increase in the hold-up is observed at low UG, and the transition point also moves toward lower superficial gas velocities (Figure 16, Figure 17 and Figure 18). This change was explained by the effect of the liquid flow, which slows down the rise of the bubbles, leading to higher hold-up—a more compact arrangement of bubbles leads to an earlier flow regime transition. Above a certain hold-up (depending on UL), the liquid superficial velocity has no more influence on the hold-up; this is possibly caused by the limited influence of the operation mode on the fully established heterogeneous flow regime. In agreement with the above-mentioned study, Jin et al. [48] also observed that the influence of working mode is lower at high ɛG.

2.2.2. Influence of the Bubble Column Design

Herein the influences of the main bubble column design criteria are discussed. The reader may also refer to the pioneering study of Wilkinson et al. [56] and to our recent paper concerning scale-up criteria [37].

Column Size

In a small diameter bubble column (Equation (1)), the wall effects alter the bubble size, rising velocity and liquid recirculation; therefore, when increasing dc, ɛG may decrease [20,30,129,130,131]. The increased recirculation was shown by Krishna et al. [130]. Urseanu et al. [131] observed the decrease in ɛG (dc between 0.15 and 0.23 m) while working with viscous fluids, in agreement with Behkish et al. [132], who noticed that the effect of the column diameter on viscous fluid is higher. The data collected by Fai et al. [105] and Yoshida and Akita [112] show that the effect of the column diameter on ɛG is negligible for columns larger than dc = 0.15 m. Hughmark [133] found an effect of column size on ɛG up to a diameter of 0.10 m. Kata [134] conducted measurements in 0.066 m, 0.122 m and 0.214 m columns and found that ɛG increases with a decreasing dc. Koide et al. [135] measured ɛG in an 0.55 m column and found no significant difference from the literature values reported for columns less than dc = 0.60 m. Deckwer [136] found a difference in ɛG between a dc = 0.041 m column and a dc = 0.10 m column. Hikita et al. [80] measured ɛG in a dc = 0.10 m column and compared their results with the ones reported in the literature for columns with dc > 0.10 m, finding no appreciable effect of dc on ɛG. Gopal et al. [106] measured the ɛG in dc = 0.2 m, dc = 0.6 m and dc = 1.0 m columns and concluded that dc and the gas sparger do not significantly influence ɛG. Nottemkamper et al. [137] measured ɛG in dc = 0.19 m, dc = 0.45 m and dc = 1.0 m columns and obtained comparable results for the dc = 0.19 m and dc = 0.45 m columns but lower ɛG values for the dc = 1 m column at high gas rates, which they attributed to its larger diameter. Koide et al. [138] observed smaller ɛG values in columns smaller than dc = 0.2 m. Accordingly to the model proposed by Lemoine et al. [139], dc has an influence in columns of up to dc = 0.70 m in either the homogeneous flow regime or in the heterogeneous flow regime. Despite some contradictory results, a generally accepted rule of thumb is that dc = 0.15 m is large enough for the results to be scalable [1,24,98,140], as supported by different investigators [8,31,141]. This scale-up criteria relies on the fluid dynamics phenomena and the coupling between the gas and liquid phases, which can be interpreted by considering the instabilities previously described in Equation (1).

Aspect Ratio

The coalescence phenomena, the local fluid dynamics (see the local results described by Xue et al. [35]), the end-effects (i.e., top column effects and near gas sparger effects) all tend to destabilize the homogeneous flow regime and decrease ɛG and are more evident in low AR bubble columns (see the experimental data summarized in Figure 19, Figure 20 and Figure 21). In particular, in systems where the bubbles are not at their maximum equilibrium size (and where coalescence may occur), the liquid height (H0) will influence the extent of the coalescence. Hence, ɛG decreases with H0, because the higher the column, the longer the time the bubbles have to coalesce and thus, the lower the mean residence time of the dispersed phase. In one of the very first studies, Yoshida and Akita [112] and Patil et al. [142] did not observe any significant effects of AR on ɛG. Wilkinson et al. [56]—when presenting the scale-up criteria—discussed the results obtained by Kastanek et al. [143]: the influence of AR is negligible for HC > 1–3 m and with AR > 5. Zahradnik et al. [8] found that ɛG decreases and the homogeneous regime is destabilized while increasing the initial liquid level up to a critical aspect ratio, ARCr; the authors concluded that their results support the assumption of a negligible influence of AR on ɛG and flow regime transitions for AR > 5. These assumptions were also confirmed by Thorat et al. [111], who found a negligible influence of AR on ɛG for AR > 5 (air-water) or AR > 8 (non-coalescing liquid phase). Sarrafi et al. [29] compared their experimental results with other experimental data and excluded any effect of the initial liquid level on the flow regime transition when H0 > 3 m. Ruzicka et al. [31] found that an increase in liquid height decreases ɛG and destabilizes the homogeneous regime up to critical values. Sasaki et al. [6] have found that an increase in liquid height destabilizes the homogeneous regime and decreases ɛG (AR up to 5). The reader may also refer to the recent discussion by Besagni et al. [37], who compared values from a large experimental dataset to demonstrate that ARCr  =  5 (Figure 19a) is ensured only for pure liquid phase systems with very large sparger openings operated in the batch mode (i.e., ARCr increases to 10 in counter-current mode (Figure 19b) and in pure liquid phase systems, with small gas sparger openings operated in batch mode (Figure 21)). The relationship between AR and the gas hold-up in batch mode is displayed in Figure 19a; conversely, Figure 19b displays the relationship between AR and the gas hold-up in counter-current mode. Other data concerning the relationship between the gas hold-up and AR for different liquid phases are discussed in the next sections, concerning the influence of the active compounds.

Gas Sparger

The gas sparger design influences not only the flow regime transition, but also the ɛG value and, specifically, the ɛG curve (the relationship between UG and εG). It is difficult to provide a general rule because of the many parameters involved (i.e., gas sparger design and operating conditions) and the controversial results presented in the literature. Despite some discrepancies, we can state that, when using a “fine distributor”, the ɛG curve increases linearly in the homogeneous flow regime, then reaches a peak and then rises again [18,19,20,32,33,82,129,145]; conversely, when using a “coarse distributor”, the ɛG curve grows continuously [19,49,111,112,131,146,147]. This was also proposed by Urseanu [19] and Deckwer [3]. The different behaviors are due to the bubble dynamics (i.e., bubble formation at the gas sparger and coalescence/break-up phenomena); in “coarse distributors” there is a continuous appearance of large bubbles [19], whereas, in “fine distributors” large bubbles start appearing after the flow transition [18]. In accordance with this discussion, “fine distributors” have higher ɛG compared to “coarse distributors” because of their narrower BSD (mainly, a lower rise velocity) [8,129,148] and, for the same distributor, a decrease in d0 leads to an increase in ɛG (mainly, a lower number of large bubbles) [30,45,123,149]. In the current authors’ opinion, these considerations can be explained by the flow regimes described in Section 2.2.1 and displayed in Figure 3.

2.2.3. Influence of the Liquid Properties

Viscous Media

In the literature, both the increase and the decrease of ɛG were observed as the liquid viscosity, μL, increased. All the apparently contradictory results can be explained by interpreting them in terms of the “dual effect of viscosity over ɛG, as described by Besagni et al. [11]—they found that ɛG continuously (and non-linearly) increases when the MEG concentration increase, up to cMEG = 5% − µL = 1.01 mPa·s, along with the contribution of small bubbles (Figure 22a). Conversely, if the concentration is further increased from cMEG = 5% − µL = 1.01 mPa·s to cMEG = 80% − µL = 7.97 mPa·s, ɛG decreases (Figure 22b). For this last concentration, the ɛG curve lies even below that obtained for pure water. The authors explained this behavior occurs because at low viscosities, the coalescence is limited, and the large drag force reduces the bubble rise velocity, causing an increase in ɛG. When the viscosity increases, the tendency to coalescence prevails, creating large bubbles rising the column at a higher velocity, thus reducing ɛG. In particular, the “dual effect of the viscosity” has been clearly observed in other experimental investigations [60,61,62,150,151,152,153]: Eissa and Schugerl [150] (dc = 0.12 m, Hc = 3.9 m, d0 = 2 mm) showed that ɛG first increases (μL < 3 mPa·s), then decreases (3 < μL < 11 mPa·s), and finally becomes roughly constant (μL > 11 mPa·s). Bach and Pilhofer [153] (dc = 0.10 m, d0 = 0.5 mm) showed that ɛG first increases (μL < 1.5–2 mPa·s), then decreases (3 < μL < 11–12 mPa·s), and finally becomes roughly constant (μL > 12 mPa·s). Godbole et al. [152] (dc = 0.305 m, Hc = 2.44 m, d0 = 1.66 mm) showed that ɛG first increases up to μL = 2.23–4.75 mPa·s, then it decreases (7.81 < μL < 52.29 mPa·s, depending on UG), and finally becomes roughly constant (μL > 52.29 mPa·s). Khare and Joshi [151] (dc = 0.20 m, Hc = 3.0 m, d0 = 2.0 mm) showed that ɛG first increases up to μL = 4 mPa·s, and then it decreases for 4 < μL < 10 mPa·s. Ruzicka et al. [60] (dc = 0.14 m, H0 = 0.2–0.8 m, d0 = 0.5 mm) showed that ɛG first increases for μ < 3 mPa·s, and it decreases for 3 < μ < 22 mPa·s. Olivieri et al. [61] (dc = 0.12 m, Hc = 2 m, H0 = 0.8 m, needle gas sparger, d0 = 0.4 mm) showed that ɛG first increases up to μL = 4.25 mPa·s, and then it decreases at higher viscosities. Concerning the remaining literature surveyed, the main results are described here. Please note that these apparently contradictory results can be explained by the above-mentioned criterion. For example, Yoshida and Akita [47,112] (dc = 0.152 m) reported that ɛG varies with μL in an irregular manner. Wilkinson et al. [56] (dc = 0.15–0.23 m, H0 = 1.2 m; d0 = 7 mm, dc = 0.158 m, H0 = 1.5 m, d0 = 2 mm) found that a high viscous liquid phase (μL = 21 mPa·s) causes a decrease in ɛG. Kuncová and Zahradnik [59] (dc = 0.15 m, Hc = 1 m, H0 = 0.5 m, d0 = 0.5 mm) investigated the effect of μL on the dynamics of bubble bed formation using several aqueous solutions of saccharose (1 < μL < 110 mPa·s)—they found a decrease in ɛG when the viscosity increased. Hwang and Cheng [154] (dc = 0.19 m, Hc = 2.5 m, d0 = 1 mm) investigated the ɛG structure in highly viscous Newtonian and non-Newtonian media and observed that ɛG decreases when the viscosity increases. Zahradnik et al. [8] (dc = 0.15 m, H0 = 0.53 m, d0 = 0.5 mm) found that moderate/high viscosities (3 < μL < 110 mPa·s) decrease ɛG. Yang et al. [57] (dc = 0.15 m, Hc = 1.7 m, d0 = 0.7 mm) investigated the influence of the viscosity (1 < μL < 31.5 mPa·s) on ɛG by using a viscosity-increasing agent; they observed that ɛG decreases when the viscosity increases. It is worth noting that the influence of the viscosity may be also described in terms of non-Newtonian behavior (and vice-versa). This point has been discussed by Besagni et al. [11] by coupling the results obtained by Olivieri et al. [61] with the “dual effect of viscosity”; the non-Newtonian related stabilization of the homogeneous flow regime proposed by Olivieri et al. [61], along with the “dual effect of viscosity” relationship between the flow regime transition and the gas hold-up, help to explain the higher ɛG for the non-Newtonian solutions observed by Godbole et al. [152].

Active Compounds

When considering active compounds, ɛG increases mainly as a consequence of homogeneous flow regime stabilization for both electrolytes [8,76,77,79,80,155,156,157,158] and ethanol [19,20,32,82,83,114,125,159,160,161] solution. ɛG also increases because the active material adsorbed at the surface is pushed towards the back of the bubble. This causes a surface tension gradient, opposing the tangential shear stress and thus increasing the drag and reducing the rise velocity. It is worth noting that some authors have also observed a dual effect for active compounds at high concentrations.

Inorganic Compounds

Previous literature focused on the influence of inorganic compounds has mainly concentrated on the relationship between εG and the concentration ratio, c ≤ ct. Zahradník et al. [8] (dc = 0.14, 0.15 and 0.29 m, Hc = 2.6 m) studied the influence of nine electrolytes and found that ɛG grew continuously for c ≤ ct, but little change in εG was observed for c > ct. These findings were also observed by Besagni et al. [28,162] in a large scale bubble column, operated both in batch mode and counter-current mode (see, for example, Figure 23). A similar dependence was found for all electrolytes at c = ct. Ribeiro and Mewes [76] (dc = 0.12 m, Hc = 1.25 m) tested three electrolytes (NaCl, Na2SO4, NaI) with four concentrations in the “coalescent flow regime”, and ɛG was found to increase up to the critical concentration. Kelkar et al. [77] (dc = 0.154 m, HC = 3.25 m) reported an increase in ɛG and a negligible effect of electrolytes (NaCl, CaCl2 and Na2SO4) above the critical concentration. Ruzicka and co-authors [69,70] (dc = 0.14 m, H0 = 0.4, d0 = 0.5 mm) observed a dual effect of inorganic compounds on ɛG and flow regime transition with respect to the electrolyte concentration. The reader may refer to [75] as well as to refs. [69,70] for a further literature review.

Organic Compounds

Previous literature regarding the influence of ethanol has mostly focused on the relationship between ɛG values and the transition point (see refs. [19,20,32,82,83])—regardless of the ɛG value, all the studies agree in regard to the increase in ɛG using ethanol solution. On the other hand, a limited number of studies considered the foaming phenomena which may occur when using organic compounds [161]. Indeed, foaming phenomena may occur as discussed in the experimental studies of Besagni et al. [7,12,37] and as predicted by the theoretical approach of Shah et al. [161]; in this respect, Figure 24 displays the gas hold-up curve in batch mode for the different aspect ratios (5  ≤  AR  ≤  12.5) and EtOH concentrations. Compared with the air-water system, the gas hold-up increases with the addition of ethanol; starting from a low ethanol concentration, the gas hold-up increases compared with the air-water case. If the ethanol concentration is further increased, foam phenomena are observed (i.e., Figure 24b and Figure 25b—reference codes are in Table 3). It is also worth noting that foaming phenomena are not only related to the concentration, but to the aspect ratio itself. A discussion on these experimental results can be found in our previous studies.
If the number of studies concerning foaming phenomena is limited, the number of studies concerning the influence of EtOh on gas hold-up are more common. Kelkar et al. [160] (dc = 0.154 and 0.3 m, HC = 2.44 and 3.35 m) studied the influence of ethanol (0.5–2.4%wt) on ɛG. Zahradnik et al. [159] (dc = 0.15 m, HC = 1.8 m) observed that the increase in ɛG was higher with longer hydrophobic chains of n-alcohols. Rollbush et al. [114] (dc = 0.16 m, HC = 1.8 m) reported an increase in ɛG using ethanol (1%vol) up to 220%, compared with tap water. Hur et al. [163] investigated the effect of adding alcohol in bubble columns on ɛG: The continuous mode decreased ɛG in the homogeneous flow regime, whereas, in the heterogeneous flow regime, it increased ɛG. The batch mode was less effective than the continuous mode in the heterogeneous flow regime. Pjoteng et al. [125] (dc = 0.10 m, HC = 1.8 m) reported an increase in ɛG with the addition of ethanol (0.5%wt), up to a pressure of 9 MPa. Guo et al. [164] studied a small diameter (dc = 0.1 m) and small-scale (Hc = 1.8 m) bubble column. They found that ɛG first increases, and then decreases, with an increasing ethanol concentration, owing to the non-linear effect of the alcoholic solution on the “coalescence-induced” and “non-coalescence-induced” bubbles. Similar results were presented by Syeda et al. [165] and by Shah et al. [161]. These studies [161,164,165,166] explain the trend of ɛG with respect to the mole fraction of one of the two components in the liquid mixture, based on the model proposed by Andrew [167].

2.2.4. Influence of Gas Properties

A variation in the gas properties may cause changes in bubble size distributions, bubble rise velocities and buoyancy [168]. Generally, the influence of the gas phase over ɛG is discussed in terms of the gas density (ρG) [169]. A variation in the gas density may result from high pressure operation [2,56,84,89,94,114,169,170], from the use of different gases [47,80,89,94,107,166,168,169,171,172,173] or from a combination of both [89,94,169]. As the influence of the operating pressure is discussed in another section (Section 2.2.1), we here discuss the influence of the gas employed. Apart from Shulman and Molstadz [171]—who reported no effect of the gas properties—the literature agrees that, in columns of at least dc = 0.15 m, higher ρG result in higher εG [56]; a variation in ρG means a variation in the residence time of the dispersed phase [114]. Also, the influence of ρG over ɛG has frequently been attributed to differences in bubble size distributions at the gas sparger [166,168,173]. Bagha et al. [166] (dc = 0.0382 m, HC = 1.14 m) and Koetsier et al. [172] reported that gases with higher density have higher ɛG. Akita and Yoshida [47] (square column, 0.15 × 0.15 m) tested four gases (air, He, O2, CO2) with water and showed that the effect of ρG on ɛG can be neglected, although ɛG with helium are slightly lower for higher gas velocities. Hikita et al. [80] (dc = 0.10 m, HC = 1.50 m) observed an effect of gas density by testing different gases (air, H2, CO2, CH4, C3H8 and H2–N2 mixtures). Sada et al. [107] (dc = 0.073 m, HC = 0.95 m) concluded that the influence of ρG on ɛG should be considered in gas–molten salt systems because of the low gas–liquid density ratio at high temperatures. Özturk et al. [173] (dc = 0.085 m, HC = 0.95 m) considered different gases (Air, H2, He, N2, and CO2) and observed that ɛG increases when ρG increases. Reilly et al. [94] (dc = 0.15 m, HC = 1.7 m) investigated various gases at atmospheric pressure (Air, Ar, He, N2, and CO2) and conducted experiments at higher pressures (dc = 0.15 m) using N2 and air in isoparaffinic solvents—higher ρG extended the homogeneous flow regime and increased ɛG, especially in the heterogeneous flow regime. Krishna et al. [89] (dc = 0.16 m, HC = 1.2–4.0 m) observed that ɛG increases with ρG as a result of both higher pressures and higher gas molecular weights (He, N2, Ar, CO2, and sulfur hexafluoride gases) in water. Jordan and Schumpe [169] (dc = 0.1 m, HC = 2.4 m) adjusted ρG by increasing the pressure and by using mixtures of He and N2; they concluded that the differences in ɛG could be attributed only to differences in ρG and not to the nature of the gas. Hech et al. [168] (dc = 0.15 m, HC = 2.2 m) tested different gases (air, He, N2, and CO2) and found that that higher gas densities lead to higher ɛG.

2.2.5. Influence of the Pressure and Temperature

Pressure

The literature agrees that an increase in pressure results in higher ɛG [1,20,56,84,85,86,88,89,90,92,93,94,95,96,97,98,116,125,131,132,169,170,174,175,176,177,178,179,180,181,182,183,184]. Moreover, the influence of the pressure over gas hold-up is non-linear with UG; whereas, in the heterogeneous flow regime, ɛG always increases, in the homogeneous flow regime, some authors have observed an increase–even if less than in the heterogeneous flow regime–and others have observed no effect [1]. The literature also agrees when reporting a plateau for a certain value of pressure, above which, no significant effect of pressure on ɛG is observed. The value of the plateau depends on the operating conditions [132], and typically, values are 6 MPa [185], 7 MPa [180] and 10 MPa [178]. The effect of pressure can be related to the liquid phase (i.e., µL and ρL) and gas phase (i.e., ρG) parameters. The liquid phase has a limited influence [180]; the parameters of the gas phase have a higher influence [1]. It is worth noting that the gas density also has an influence over ɛG at ambient pressure (Section 2.2.4). Ishiyama et al. [177] (CO2/water) reported a negative effect of pressure on ɛG at pressures above 0.8 MPa in a heterogeneous flow regime; this behaviour was explained by an increase in μL with dissolved CO2.

Temperature

Most of the authors reported a positive effect of the temperature, Tc, over ɛG [56,86,117,132,177,180,181,186,187,188]; on the other hand, Pohorecki et al. [187] observed no effect of Tc—possibly caused by the evaporation—and some authors observed a decrease of ɛG Tc increased [78,136,189,190]. It is worth noting that the studies reporting a decrease in ɛG used at low UG and, in accordance with Yang et al. [190], turbulence is low under these conditions,. Under these conditions, an increase in Tc, reduces the viscosity and weakly promotes turbulence; this promotes collision and increases film drainage speed and thus, coalescence. Grover et al. [78] (dc = 0.1 m, Hc = 1.5 m, air-water) observed a negative effect of Tc at atmospheric pressure (Tc between 303 and 353 K), although for Tc > 323 K, the effect of temperature is limited. Deckwer et al. [136] (dc = 0.041 m, N2/Paraffin system) observed a decrease in ɛG until a plateau was reached. For the same range of UG and for the same dc as that of Deckwer et al. [136], Kölbel et al. [189] (dc = 0.041 m, Hc = 4 m, H2, Ethylene/C13–18) observed the same decrease in the homogeneous flow regime, but no effect in the heterogeneous flow regime. Yang et al. [190] (dc = 0.041 m, H2, CO/Paraffin) observed a decrease in ɛG with an increase in both Tc (293–523 K) and pc (1–3 MPa).

2.2.6. Gas Hold-Up Correlations

Different correlations have been proposed in the last few decades to correctly predict ɛG in two-phase bubble columns. This section summarizes and described some frequently used ɛG correlations. In particular, Table 4 summarizes the range of applicability of the reported correlations. In particular, in the following sub-sections, the main gas hold-up correlations are presented grouped in six main schemes of correlation: (a) the scheme of correlations by Lockett and Kirkpatrick; (b) the scheme of correlations based on εG; (c) the scheme of correlations by Akita and Yoshida [47]; (d) the scheme of correlations for Newtonian and non-Newtonian liquid phases; (d) the scheme of correlations based on the work of Syeda et al. [165]; (e) the scheme of correlations for bubble column scaling-up.

Scheme of Correlations by Lockett and Kirkpatrick

In 1975, Lockett and Kirkpatrick [191] proposed a fundamental scheme of correlations, which served as the basis for many subsequent studies; they tested different equations to describe ideal bubbly flow, and they found that for db = 0.0005, none of the proposed equations are completely satisfactory. They concluded that the Richiardon and Zaki equation with exponent 2.39 is adequate if a correction factor is also included to take bubble deformation into account. Therefore, they proposed the following correlation:
u G ( 1 ε G ) + u L ε G = V b ε G ( 1 ε G ) 2.39 ( 1 + 2.55 ε G 3 )

Scheme of Correlations Based on εG: From Hugmark towards Reilly et al.

The first gas hold-up correlation presented was the well-known Hughmark [133] correlation; this correlation is based on his experimental data, which takes into account the effect of the liquid properties; this correlation was based on the observation that the gas hold-up for the air-water system in batch mode is correlated with the non-dimensional number, defined as U G [ ( 1 / ρ L ) ( 72 / σ ) ] 1 / 3 . The correlation reads as follows:
ε G = 1 2 + ( 0.35 U G ) [ ( ρ L 1 ) ( σ 72 ) ] 1 / 3
Mashelkar [192] suggested a non-linear correlation to predict ɛG values in air-water bubble columns in both the homogeneous flow regime and the transition/heterogeneous flow regime:
ε G = U G 0.3 + 2 U G
As observed by [106], at low values of UG (in the homogeneous flow regime) the denominator is approximately constant and ɛG increases linearly with UG. At relatively high values of UG (in the transition/heterogeneous flow regime), ɛG decreases as UG increases. A scheme of correlation, similar to the one proposed by Mashelkar [192], was proposed by Kato and Nishiwaki [193], as reported by [24,193] and shown in Equation (6):
ε G = 2.51 U G 0.78 + β U G 0.8 ( 1 e γ )
where the terms in Equation (6) reads as follows: β = 4.5 3.5 2.548 d c 1.8 and γ = 717 ( U G 1.8 / β ) . Another modification of Equation (5) was proposed by Koide et al. [135] (Equation (7)), who conducted research to find the effect of the column diameter on flow properties using a commercial-scale, 5.50 m diameter column, approximately 7.00 m in liquid height. The measured values of the average gas hold-up show a certain amount of scatter, but when UG is less than approximately 5 [cm/s], they almost agree with the values calculated by Kato et al. [134] when dc = 5.50 m:
ε G = U G 31 + β ( 1 e ) U G
where the terms in Equation (7) read as follows: β = 4.5 3.5 exp ( 0.064 d c 1.3 ) and e = [ 0.18 U G 1.8 / β ] . Hikita and Kikukawa [194] correlated the measured ɛG, in air–various liquid systems with Equation (8):
ε G = 0.505 U G 0.47 ( 72 σ ) 2 / 3 ( 1 μ L ) 0.05
Grover et al. (1986) [78] proposed a modified form of Hikita’s correlation ([80]) to incorporate the influence of temperature on the physical properties. Their correlation is given by Equation (9) where the constants, a and b, have been found to be 1.1 × 10−4 and 5 × 10−4, respectively. The vapor pressure (Pv) of the solvent has been used as a correlating term to account for the temperature effect:
ε G = ( 1 + a P v b P v ) ( U G μ L σ L ) 0.76 ( μ L 4 g ρ L σ L 3 ) 0.27 ( ρ G ρ L ) 0.09 ( μ G μ L ) 0.35
Gestrich and Rähse [195] correlated the literature data for ɛG and suggested the following equation, which takes into account the liquid properties, the column dimensions and the operating variables:
ε G = 0.89 ( H c d c ) 0.035 ( 15.7 + log ( ρ L σ 3 g μ L 4 ) ) ( d b d c ) 0.3 ( U G 2 g d b ) 0.025 ( 2.6 + log ( ρ L σ 3 g μ L 4 ) ) ( ρ L σ 3 g μ L 4 ) 0.047 0.05
In Equation (10), the mean bubble diameter (db), usually ranging between 0.002–0.004 m, has been found to have no significant effect on ɛG. Therefore, db = 0.0003 m can be used in the equation.
Kumar et al. [196] presented the ɛG data for air in several liquids and found that their own and the previous investigators’ data can be correlated using Equation (11) as a function of the dimensionless gas velocity, U = u G [ ρ L 2 / σ ( ρ L ρ G ) g ] 1 / 4 as follows:
ε G = 0.728 U 0.485 U 2 + 0.0975 U 3
As reported by [108], this expression should be used for gas rates below 0.10 [m/s]; at higher gas velocities it exhibits a maximum value.
Friedel et al. [197] reported a correlation for calculating the gas hold-up in downhole bubble columns. It has the form of Equation (12), as reported by [24]:
ε G = [ 1 + 0.0685 ( 1 ε ) 3.112 ε 0.395 ( ρ L ρ G ) 0.0346 ( μ L μ G ) 0.254 ( I 2 g d c / ( ρ L σ ) ) 0.36 ( I 2 d c ρ L σ ) 0.543 ] 1
where ε = U G U G + U L .
Hikita et al. [80] obtained experimental data on the fractional ɛG in bubble columns with various gases and pure liquids or aqueous solutions of non-electrolytes as well as for air in aqueous solutions of various electrolytes. These data have been used to study the effects of the physical properties of gas and liquid on the gas hold-up. As a result, a new dimensionless correlation has been presented and reads as follows:
ε G = 0.672 f ( U G μ L σ ) 0.578 ( μ L 4 g ρ L σ 3 ) 0.131 ( ρ G ρ L ) 0.062 ( μ G μ L ) 0.107
where f represents the correction factor, which is the factor by which ɛG is increased by the presence of electrolytes in water. It assumes different values depending on the ionic strength (I). As the exponents show, the physical properties of the gas phase are of little relevance, but, if omitted, the mean deviation of the correlated data rises to 15% as opposed to 4% when included. Such properties could affect the relative gas hold-up, especially under high pressure conditions, but no systematic research has yet been done on this particular aspect.
Reilley et al. [108] used a statistical approach, instead of performing a dimensional analysis, to develop a generalized correlation for gas hold-up which would cover the entire range of the physical properties (uG, σ, ρG, ρL, μG, μL) of both the gas and liquid involved in their study. The result of their analysis using a non-linear multi-regression technique is given by Equation (14), and is in good agreement with their experiment and also with thirteen literature datasets selected by the authors to correspond to its region of validity. For example, only data for columns of at least 0.15 m in diameter were considered:
ε G = 296 U G 0.44 ρ L 0.98 σ 0.16 ρ G 0.19 + 0.009
Elgozali et al. [198] fitted data on gas hold-up in the bubble column for all studied batches (coalescent and non-coalescent) and two types of ejector. In the non-coalescent system, the size of the primary gas bubbles generated in the ejector stayed almost the same during their journey along the bubble bed. In coalescent systems, the effect of primary gas dispersion was suppressed by fast coalescent at the column bottom. Therefore, they correlated the two subsets separately and they ended up with a power–law empirical formula (Equation (15)), where the kinematic surface tension χ = σ / ρ L [m3/s] is used instead of the surface tension (σ):
ε G = K U G a ν L b χ c
The empirical constants are reported in Table 5. It can be inferred that the effect of liquid phase properties, characterized by the exponents b and c, respectively, is almost identical in both classes of batches, while a significant difference arises in exponent a for the superficial gas velocity, which depends on the flow regime.

Scheme of Correlations Based on εG/(1 − εG)4: The Akita and Toshida Scheme

Akita and Yoshida [47] measured the gas hold-up for different gas–liquid systems and by means of dimensional analysis, proposed the well-known gas hold-up correlation shown in Equation (6):
ε G ( 1 ε G ) 4 = c 1 ( g D 2 ρ L σ ) 1 / 8 ( g D 3 ν L 2 ) 1 / 12 ( u G g D )
In Equation (16), the c1 = 0.20 for non-electrolyte systems, whereas c1 = 0.25 has been suggested for electrolyte solutions which cause a larger ɛG compared with non-electrolyte liquids (as discussed in the previous sections). Equation (6) is still considered the state of the art in gas hold-up correlations. Mersmann [199], as reported by [24], proposed a correlation similar to Equation (16) in [47]:
ε G ( 1 ε G ) 4 = 0.14 u G ( ρ L 2 σ ( ρ L ρ G ) g ) 1 / 4 ( ρ L 2 σ 3 μ L 4 ( ρ L ρ G ) g ) 1 / 24 ( ρ L ρ G ) 5 / 72 ( ρ L ρ L ρ G ) 1 / 3
A discussion concerning this scheme of correlation has been provided by Santus and Salvagno [200]. A similar scheme of correlation was used by Bach and Pilhofer [153], Riquarts and Pilhofer [201] and Iordache et al. [202]. In particular, Bach and Pilhofer [153], as reported by refs. [24,203], proposed a gas hold-up correlation for pure organic liquids over a wide viscosity range:
ε G 1 ε G = 0.115 ( U G 3 ν L g ( ρ L ρ G ) / ρ L ) 0.23
Equation (18) does not apply to glycerol solutions because, as concluded by the authors themselves, in this system, the gas hold-up is substantially different since it exhibits a maximum at about 2–3 [mPa∙s], owing to “the dual effect of the viscosity”. A modified version of Equation (17) was proposed by Riquarts and Pilhofer [201], as reported by [204]; the proposed correlation for an air-water system reads as follows:
ε G 1 ε G = 0.11 ( U G 3 ν G ) 1 / 4
Iordache et al. [202] interpreted results concerning the dependence of the bubble void fraction on the superficial velocity in a gas–liquid dispersion in a bubble column using a stochastic model for the flow phenomena, based on ū° (viz. the mean individual velocity):
ε G ( 1 ε G 1 / 3 ) = U G u ¯ °
Sada et al. (1984) [107] modified the equation used in [47] by including the term, gas–liquid density ratio, to better stress the influence of the gas phase:
ε G ( 1 ε G ) 4 = 0.32 ( g d c 2 ρ L σ ) 0.121 ( g d c 3 ν L 2 ) 0.086 ( U G g d c ) ( ρ G ρ L ) 0.068

Scheme of Correlations for Newtonian and Non-Newtonian Liquid Phases

Godbole et al. (1982) [152] determined the fractional gas hold-ups using the dynamic disengagement method in a 0.305 m diameter bubble column, and they presented empirical correlations based on data covering wide ranges of viscosities in Newtonian and pseudoplastic non-Newtonian solutions. From the measurements for water–glycerine solutions in the viscosity range 0.00423–0.246 Pa∙s, they proposed the following correlation, which can be used to predict the the gas hold-up prediction in viscous Newtonian liquids:
ε G = 0.319 U G 0.476 μ L 0.058
The gas hold-up data for CMC (Carboxymethyl cellulose) solutions have been correlated with another empirical correlation (Equation (22)), which is based on the data covering an apparent viscosity of 0.018–0.230 Pa∙s. The apparent viscosity is given by μ L = K ( 5000.0 U G ) n 1 , where K is the consistency index and n is the flow behavior index:
ε G = 0.225 U G 0.532 μ L 0.146
Another correlation for highly viscous CMC solutions (≥0.02 Pa∙s) has been proposed similarly to those presented by [205] for 0.102 and 0.14 m diameter bubble columns:
ε G = 0.42 U G 0.624
Using the gas hold-up data for highly viscous CMC solutions (≥0.02 [Pa∙s]) in the three bubble columns (the two columns used by [205] and the one used by [152]) Godbole et al. [152] proposed the following empirical correlation to also take into account the diameter effect:
ε G = 0.239 U G 0.634 d c 0.50
Viswanathan and Rao, on the basis of the cell model [206], obtained a correlation (Equation (26), reported by [204]), in which ubr is the bubble rising velocity. It predicts a dependency of the gas hold-up on the column diameter which is similar to that in the model proposed by [204] but somewhat smaller:
ε G = 0.574 ( u b r g d c ) 0.4 ( U G u b r ) 0.8
Kawase and Moo-Young [207] proposed the following empirical correlation (Equation (27)), where νa is the apparent kinematic viscosity and the apparent dynamic viscosity is expressed in terms of the consistency index, K, as follows μ a = K γ ˙ n 1 = K ( 2 U G / d c ) n 1 :
ε G = 0.24 n 0.6 ( U G g d c ) 0.84 0.14 n ( g d c 3 ν a ) 0.07
It is important to highlight that Kawase and Moo-Young [207] suggested that a more precise correlation should also account for the effect of the surface tension on the gas hold-up which they have not included. In addition, Kawase and Moo-Young [204] developed a theoretical model for gas hold-up in bubble columns with Newtonian and non-Newtonian fluids using the concept of a characteristic turbulent kinematic viscosity in bubble columns:
ε G = 1.07 n 2 / 3 ( U G 2 g d c ) 1 / 3
Their correlation seems to be in reasonable agreement with the available data for Newtonian fluids over a wide range of column diameter (D = 0.1–1.07 [m]). However, to better correlate the experimental data for large bubble columns (D = 5.5 [m]) obtained by [208] which lie significantly above their model, Kawase and Moo-Young [204] proposed another correlation:
ε G = 3.38 ( U G 2 g d c ) 1 / 3
Schumpe and Deckwer [203], based on a review of literature data as well as on their own experimental data, developed a single correlation for different viscous Newtonian and non-Newtonian solutions. Two hundred hold-ups were correlated using the same dimensionless numbers suggested by [47]. However, instead of the group ε G / ( 1 ε G ) 4 the gas hold-up itself was empirically correlated for simplicity, leading to Equation (30):
ε G = 0.2 ( d c 2 ρ L g σ ) 0.13 ( g d c 3 ρ L 2 μ e f f 2 ) 0.11 ( U G g d c ) 0.54
Equation (30) is suggested for the gas hold-up in the heterogeneous flow regime; conversely, in the slug flow regime, a theoretical approach has been found to apply, leading to Equation (31):
ε G = ( C U G + U L U G + 0.35 / ( U G g d c ) ) 1
Zou et al. [209] developed a gas hold-up correlation, implicating an effect of the operating temperature in the range of 25–96.56 °C. Following what was reported by [47,80], they neglected the effects of the nozzle diameter, the column diameter, the clear liquid height and the superficial liquid velocity. Thus, the factors affecting the gas hold-up were considered to be the superficial gas velocity, the liquid density, the liquid viscosity, the surface tension of the liquid, the gravitational constant and the liquid vapor pressure, which have been correlated by Equation (32):
ε G = 0.17283 ( μ L 4 g ρ L σ L 3 ) 0.1544 ( U G μ L σ L ) 0.5897 ( P + P v P ) 1.6105
For the air–5% NaCl solution, the correction factor, f, has been defined as f = εGG°, where εG° is the calculated values from Equation (32) for the electrolyte solutions. This correction factor has been found to depend on the operating temperature (Table 6). The vapor pressure of liquid (Pv) was used to indicate the effect of temperature on the gas hold-up, since the change tendency of the gas hold-up with temperature is basically similar to the relationship between Pv and temperature. An increase in temperature results in an increase in the gas hold-up, particularly above 75 °C, 65 °C and 80 °C for the air-water, air–alcohol and air–5% NaCl systems, respectively. Zou et al. [209] also observed that εG (air–alcohol) > εG (air–5%NaCl) > εG (air-water). Finally, Kawase et al., in their review on bubble column reactors, [140] reported the correlation proposed by [210] and given by Equation (33):
ε G 1 + ε G = 0.0625 ( U G ν L g ) 1 / 4

Scheme of Correlations of Syeda et al.

One of the most famous and promising schemes of correlation that also accounts for the “dual effects” was proposed by Syeda et al. [165]; they used the same four dimensionless groups proposed by [80] and adopted them into their correlation for pure liquids (Equation (34)) which includes the probability factor as the bubble stability criterion:
ε G = c 1 [ ( W e 2 ) 1 / 2 ] b ( U G μ L σ ) 0.578 ( μ L 4 g ρ L σ 3 ) 0.131 ( ρ G ρ L ) 0.062 ( μ G μ L ) 0.107
The constant (c1) and the exponent (b) have been determined experimentally in combination with the model proposed for binary mixtures (Equation (35)), where We1 and We2 represent the Weber numbers of the pure liquids with lower and higher surface tensions, respectively, in the binary mixtures:
ε G = c 1 [ x ( W e 1 2 ) 1 / 2 + ( c r k 2 σ ) + ( 1 x ) ( W e 2 2 ) 1 / 2 ] b ( U G μ L σ ) 0.578 ( μ L 4 g ρ L σ 3 ) 0.131 ( ρ G ρ L ) 0.062 ( μ G μ L ) 0.107
At x = 0 or 1, the correlation coincides with the model suggested for pure liquids (Equation (35)). By comparing the second equation with experimental gas hold-up data for four pure liquids and four organic binary mixtures, the values of c1 and b have been found to be 1.334 and 0.032, respectively. The Weber numbers used in the two equations have been derived strictly for pure liquids. Changes in bubble size and bubble mobility that might affect the gas hold-up of the mixtures are included in the frothing parameter, c r k 2 / σ .

Scheme of Correlations for Bubble Column Scaling-Up

In 1992, Wilkison et al. [56] proposed a well-known gas hold-up correlation for bubble column scaling-up. Later, Besagni and Inzoli [211] proposed a generalization of the original correlation which also takes the bubble column geometrical parameters into account. The scheme of the gas hold-up correlation reads as follows:
ε G = { U G U n o n c o a l e s c e n c e   i n d u c e d   b u b b l e s U G < U G , t r a n s U G , t r a n s U n o n c o a l e s c e n c e   i n d u c e d   b u b b l e s + U G U G , t r a n s U c o a l e s c e n c e   i n d u c e d   b u b b l e s U G > U G , t r a n s
where Ucoalescence induced bubbles and Unon-coalescence induced bubbles and are the rising velocity of the “coalescence induced” bubbles and the “non-coalescence induced” bubbles, respectively. The different terms in Equation (36) were derived by changing the equation of Wilkinson et al. [56] as follows:
U G , t r a n s = 1.55 U n o n c o a l e s c e n c e   i n d u c e d   b u b b l e s e 193 ρ G 0.61 μ L 0.5 σ 0.11 D H 0.5 A R 0.31 d o 0.01
U n o n c o a l e s c e n c e   i n d u c e d   b u b b l e s = 1.125 σ μ L ( σ 3 ρ L g μ L 4 ) 0.273 ( ρ L ρ G ) 0.03 D H 0.4 A R 0.3 d o 0.39
ε G = { U G U n o n c o a l e s c e n c e   i n d u c e d   b u b b l e s U G < U G , t r a n s U G , t r a n s U n o n c o a l e s c e n c e   i n d u c e d   b u b b l e s + U G U G , t r a n s U c o a l e s c e n c e   i n d u c e d   b u b b l e s U G > U G , t r a n s
In Equations (37)–(39), the non-dimensional groups are defined as follows: dimensionless diameter (D*H–Equation (1)), the dimensionless bubble column height (AR, aspect ratio refs. [28,144]), and the dimensionless sparger opening (d*o); the last one is defined as the ratio between the bubble size produced at the gas sparger, estimated by the correlation in ref. [212], as the diameter of the gas sparger opening.

2.3. The Bubble Size Distribution and Shapes

An understanding of the bubble properties, size distribution and shapes and rising velocity is of fundamental importance for understanding and modeling the flow dynamics and mass transfer phenomena in bubble columns (see, for example the review of Risso [213]). Indeed, in the current authors’ opinion, the stabilization/destabilization of the homogeneous flow regime and thus, the changes in ɛG are caused by the modifications to the BSDs connected to the bubble interface properties [65,214,215]. Besides this concept, using a practical point of view, apart from ɛG, another fundamental parameter for the bubble column fluid dynamics is the bubble size distribution (BSD) which provides, along with ɛG, an evaluation of the interfacial area [140] and is used in computational luid dynamics (CFD) for model set-up and validation [9]. The variation in the BSD is among the main reasons for the effects of the operating parameters on ɛG and the flow regime transition (i.e., stabilization of the homogeneous flow regime, increase in ɛG and, eventually, the plateau effect). In addition to the BSD, the bubble shapes should be considered (i.e., the aspect ratio). Indeed, the interface shape and size is important for characterizing multi-phase flows properly (i.e., heat and mass transfer at the interface and the closures in computational fluid dynamics). Generally speaking, the bubble shape depends on the system variables (as discussed by Haberman et al. [216]): the bubble rising velocity (ub), the equivalent bubble diameter (deq), the difference between the phase densities (ρLρG), the liquid viscosity (μL), the gas phase viscosity (μG), the surface tension (σ) and the gravity acceleration (g). These variables are coupled into non-dimensional numbers:
  • the Eötvös number:
    E o = g ρ L d e q 2 σ
  • the Morton number (defined only by the properties of the phases):
    M o = g ( ρ L ρ G ) μ L 4 ρ L 2 σ 3
  • the Reynolds number:
    R e = ρ L u b d e q μ L
  • the Weber number:
    W e = R e 2 ( M o E o ) 1 2
These non-dimensional numbers are used for relating the bubble properties, as shown by Clift et al. [217] for bubbles rising in an infinite medium. Clift et al. [217] proposed a graphical correlation to relate the bubble properties in terms of Eötvös (Eo), Morton (Mo) and Reynold (Reb) numbers. For a constant Morton number, the bubble shape evolves from spherical to ellipsoidal to cap-shaped when increasing its equivalent diameter (corresponding to the Eötvös number) (see, for example, the flow visualistaions in refs. [7,11]). The bubbles may be considered spheres when the surface tension and/or the viscous forces are larger than the inertial forces. Ellipsoidal bubbles are defined as oblate spheroid (an axisymmetric ellipse with respect to the minor axis). For example, Chao [218] argued that air bubbles in the water phase maintain a spherical shape up to Re = 400. When Re > 400, bubbles become flatted: first spheroidal and subsequently, spherical-cap bubbles. The rule of thumb is that bubbles having aspect ratio larger than 0.9 are spherical. Several attempts have been made in the literature to correlate the aspect ratio to dimensionless parameters (see refs. [219,220,221]): Eo [222,223], We [223,224,225], Tadaki number [217,226], the Mo and the Eo numbers [227] and the Re and the Eo numbers [228]. Unfortunately, most of these correlations were developed for single bubbles/drops, and they may not be suitable for dense bubbly flows, as discussed by Besagni et al. [11,53,229]. To this end, Besagni et al. [12,229] proposed a correlation for the bubble aspect ratio (E) for dense bubbly flows which reads as follows:
E = f ( W e , R e , E o , F r , N μ r ) f ( E o ) = f ( g Δ ρ d e q 2 σ ) = { z 1 a 2 + z 2 a + z 3 a < 0.55 k 1 a k 2 0.55 < a < 5.5 z 4 a z 5 a > 0.55
In Equation (44), a is the major axis of the bubble; in particular, the coefficients in Equation (44) were obtained by experimental data and are listed in Table 7. Another correlation for dense bubbly flows, valid only for air-water systems, was proposed by Besagni and Inzoli [53]; it has been further validated by Besagni et al. [230] and reads as follows:
E = 1 1 + 0.0553 E o 0.266
The reader should refer to Besagni et al. [230] for a discussion concerning the prediction of the bubble aspect ratio in dense bubbly flows under different experimental setups.

2.3.1. Influence of the Bubble Column Design and Operation

Superficial Gas Velocity

The precise understanding of the relationships between the bubble shape and size and the gas and liquid velocities provide valuable information concerning the relationships between the bubble shape and the “reactor-scale” flow conditions, as stated by Ziegenhein et al. [231]. Unfortunately, as discussed by Leoeonard et al. [1] the influence of the superficial gas velocity over db is far from being understood and controversial results have been published. It is generally admitted that—in the homogeneous flow regime—db increases [156] and, after the transition, “coalescence induced” bubbles appear, whereas the contribution of the “non-coalescence induced” bubbles remain constant [18]. Some authors reported an increase in db with superficial gas velocity, both in the homogeneous and heterogeneous flow regimes [35,38,85,87,127,183,232,233,234,235,236,237,238,239], while other authors reported no effect of UG over db [188,240] and some others reported a decrease in the bubble size [241]. In the literature, both unimodal [239] and bimodal [242,243,244,245] BSD have been found depending on the gas sparger design and operating conditions. Lau et al. [242] and Wongsuchoto et al. [244] observed a transition from unimodal BSD to bimodal BSD with increasing superficial velocity of the air. This change in the distribution of bubble size has been justified by increased coalescence [242] or break-up [244]. Besagni and Inzoli [46,52,53,229] described the BSDs in a polydispersed homogeneous flow regime in the batch and counter-current modes. The changes in the BSD (from bimodal to unimodal) in the counter-current mode were based on the force pushing the small bubbles toward the center of the pipe. This has been confirmed by the numerical studies of Lu et al. [246] and Lu and Tryggvason [247,248]. Generally, lot of parameters influence the bubble size distribution, and it is difficult to provide a general rule for BSD prediction. Similarly, the influence of the superficial gas velocity over the bubble shape (viz. the bubble aspect ratio, E) is far from being understood. For example, Figure 25, Figure 26 and Figure 27 present the experimental findings of the relationships between E and the gas and liquid superficial velocities, obtained by the PoliMi and HZDR research groups (see, for example, refs. [7,12,46,53,229,230,231,249,250,251]). These experimental findings concern air-water flow; experimental results concerning other working fluids are summarized in ref. [12].
Generally speaking, from the above-reported experimental findings, it can be observed that a general relationship between Eo and E seems to exist; larger bubbles seem to be characterized by lower E and thus, are likely to be flattered (E is in the range of 0.4–0.7); conversely, the small bubbles have higher E and thus, are likely to be spherical (e.g., if deq > 1 mm, E > 0.7). It can be observed that, in the different cases considered, changing UL and UG does not affect the E significantly. A detailed discussion of the above-mentioned experimental findings can be found in ref. [230] and thus, it is not repeated here. A valuable conclusion is that the relationship between bubble size and shape (in the boundaries of the homogeneous flow regime) mainly depends upon the liquid phase properties and not on the flow conditions (i.e., the gas and liquid flow rates). Generally, distinct differences are observed in smaller bubbles, whereas the aspect ratios approach each other with increasing bubble size. It is also worth noting that, in some flow conditions, it is found that as the bubble shape is not highly dependent on the flow conditions, it can be speculated that, in these cases, E mainly depends on the prevailing bubble size distribution, rather on the existing flow pattern [250].

Gas Sparger Design

The gas sparger design (i.e., the hole opening and the number of holes) along with the properties of the phases and the operating conditions determines the BSD at the gas sparger region that will, thus, evolve into the BSD in the developed region of the column. A review concerning the bubble formation in gas–liquid systems was proposed by Kulkarni and Joshi, to whom the interested reader should refer [252]. The role of the gas sparger in the BSD was investigated by Camarasa et al. [253] and Polli et al [254] for coarse and fine distributors and by Miyahara and Tanaka [255] and Koide et al. [256] for porous gas spargers. Generally speaking, a “coarse distributor” ensures a narrow/uniform sized BSD [8,13,129,148]. On the other hand, a larger opening would generate a larger bubble that would evolve into a log-normal or more complex BSD—see, for example, the brief discussion proposed by Besagni et al. [14]. An insight into the bubble formation process at the gas sparger is given by Hur et al. [257] for a single nozzle and by Kazakis et al. [258] for a porous gas sparger considering different liquid phases. Finally, Besagni et al. [7,46] investigated the BSDs near the gas sparger, the phenomena in the developing BSDs and compared their results with correlations from the literature.

2.3.2. Influence of the Liquid Properties

Viscous Media

Generally speaking, high viscous media are characterized by more stable interfaces and thus, promote the formation of large bubbles at the gas sparger [3,259], bubble coalescence [3,56,58,59] and decreases in the bubble breakup rate [24,56]. Viscous liquid phases also change the nucleation process [260] as the bubble detachment in viscous liquid phase ins mainly determined by the viscous forces, rather than the inertial and surface tension forces [261]. In highly viscous media, a bimodal BSD is observed—for example, deq < 1 mm and deq > 20 mm [262], 1 mm < deq < 10 mm and 10 < deq < 150 mm [152], 0.7 mm < deq < 10 mm and deq > 10 mm [57]. Rahba et al. [62] reported bimodal BSD with large bubbles having deq = 40–45 mm. For example, for viscosities beyond μL > 30 mPa·s, the contribution of the small bubbles results in a further increase in the total ɛG with increasing viscosity [59], instead of the levelling at a constant value, as reported by Eissa and Schugerl [150]. An exception to the above references is the study of La Rubia et al. [241], who observed a decrease of deq from 4.6 to 4.2 mm while increasing UG. Besagni et al. reported a “dual effect of viscosity on BSDs”; the BSDs shifted towards low equivalent diameters for “low/moderate” viscosities and, for higher viscosities, cap-bubbles appeared in addition to the spherical–ellipsoidal bubbles. This behavior has been explained by two simultaneous effects: (i) at higher viscosities, coalescence is promoted and large bubbles appear; (ii) moderate viscosities stabilize and increase the boundary layer thickness between the bubbles, resulting in a decrease in the coalescence rate of the small bubbles (the momentum of the bubbles could not overcome the layer thickness). Similar behavior was observed by Yang et al. [57] in small scale bubble columns, using a “fine gas sparger”; they interpreted the increase in the number of small bubbles at moderate viscosities using the stabilization effect of the bubbly layers [60]. It is worth noting that increasing the liquid phase viscosity not only changes the prevailing bubble shape, but also the bubble dynamics (e.g., rising and horizontal velocities and bubble trajectories), owing to the balance between viscous and non-viscous forces [263]; the changes in the bubbly dynamics have been observed also from the point of view of aggregated bubbles [264]. Unfortunately, up to now, detailed experimental and numerical investigations on the bubble interface in viscous media have been quite limited, and there is a lack in fundamental knowledge, as reviewed in refs. [265,266]. Recently, Orvalho et al. [267] found that the bubble contact time increases with μL, passing through three phases: (a) a rise at low μL; (b) a jump at intermediate μL; (c) a plateau at high μL. This result seems to contradict with the above-mentioned findings and may be related to the diffuser flow conditions (i.e., the differences between bubble rising the bubble column and experiments on pair-wise bubbles); in regard to this concept, the interested reader may refer to the experimental study of Sun et al. [268]. Of course, future research studies should be devoted to performing 3D numerical simulations (e.g., see refs. [269]) and obtain local measurements, to study the bubble interface in viscous liquid phases and the bubble shapes and dynamics (e.g., see the pioneering study of Bhaga and Weber [166] and more recent papers [259,268]).

Active Compounds

When using active compounds, the bubble size distribution changes because of coalescence suppression, and a decrease in db is expected (along with an increase in ɛG) [8,38,56,80,108,127,149,161,234,241,253,270,271]. Among the broader literature on the topic, we present some examples for the sake of clearness. Keitel et al. [270] found that the BSD shifts toward lower diameters when employing non-coalescing solutions. This was also observed by Shah et al. [161] (ethanol–water mixtures) and by Machon et al. [271], who observed a dependency on the active compound concentration. They found that, depending on the mixture concentration, the bubble diameter in water is much higher than in electrolyte and alcohol solutions (c > ct) or, if cct, the diameter is midway between the one in water and the one for c > ct.

Influence of the Gas Properties

It is thought that a possible cause for the differences in ɛG, when changing the type of gas, is due to changes in bubble size distribution [166,168,173]. Koetsier et al. [172] postulated that argon coalesces less than helium near gas spargers. Özturk et al. [173] linked the higher ɛG to smaller bubbles formed at the gas sparger. Hecht et al. [168] concluded that the most probable causes of the differences in ɛG are the changes in bubble size distributions (caused by the changes in the break-up and coalescence rate) as well as dissimilar bubble rise velocities.

2.3.3. Influence of the Pressure and Temperature

Pressure

An increase in pressure results in a decrease in bubble size (db) [1], and some authors have reported a decreased bubble velocity and an increased number of bubbles [87,98,272]. The multiple effects of pressure were also found by Jiang et al. [178], who observed a plateau for ɛG at approximately 10 MPa and a plateau for bubble diameter at approximately 1.5 MPa; this suggests that pressure has another effect that decreases bubble diameter. Lin et al. [180] (up to 16 MPa) observed a decrease in db when pressure increased for a fixed UG (0.02 and 0.08 m/s): from db = 2.7 mm (pc = 0.1 MPa) to 2 mm (pc = 3.5 MPa), 1 mm (pc = 7 MPa) and 0.8 mm (pc = 15.2 MPa). Schäfer et al. [183] (pc = 0.1–5.0 MPa) observed a decrease in db while increasing pressure with different gas spargers at an ambient Tc in the homogeneous flow regime. Letzel et al. [91,92,170] (pc = 0.1–1.3 MPa) reported that the pressure has an influence over large bubbles only, suggesting that, in the homogeneous flow regime, the influence of pressure may be also negligible. The influence of pressure over db is related to the gas sparger employed—Maalej et al. [182] (pc = 0.1–5.0 MPa) reported a lower influence of pressure for porous gas spargers than for perforated gas spargers (because of the narrow BSD in “fine distributors”). Kölbel et al. [189] (pc = 0.1–0.6 MPa) attributed the absence of a pressure effect in both the homogeneous or heterogeneous flow regimes to the narrow BSD at the gas sparger. Oyevaar et al. [185] (pc = 0.1–8.0 MPa) observed higher effects of pressure in perforated gas spargers than in porous gas spargers. Idogawa et al. [176] (pc = 0.1–15.0 MPa) found that the influence of the gas sparger becomes lower as the pressure increases. The effect of the pressure is also influenced by the other operating parameters, such as liquid phase viscosity, the chemical reactions and high temperature. In these cases, the effect of pressure may be reduced by the opposite influence of the other parameters. Urseanu et al. [131] (pc = 0.1–1.0 MPa) reported a minor effect of pressure on ɛG while working with viscous fluids, because of the opposite effect of pressure and viscosity on db. Ishibashi et al. [273] (pc = 16.8–18.6 MPa) observed no effect of pressure in the presence of chemical reactions. Considering previous high pressure and temperature studies, it seems that there is a negligible influence of pressure, as reported by Soong et al. [188] (Tc = 293–538 K, pc = 0.1–1.36 MPa), Sangnimnuan et al. [115] (Tc = 437–537 K, pc = 4.5–15.0 MPa) and Pohorecki et al. [187,240] (Tc = 303–433 K, pc = 0.1–1.1 MPa). These results may be explained as occurring due to the saturation of gas through the evaporation of liquid, resulting in an increase in db [56,187,240].

Temperature

Increasing the temperature reduced the surface tension, thus enhancing the bubble break-up and moving the BSD towards a lower diameter. Also, an increase in the temperature has also an influence in viscosity, which is reduced, thus promoting coalescence [1]. Therefore, the reduced surface tension and viscosity have opposite effects, but generally, a decrease in deq is observed with an increase in temperature [180,183,188]. Lin et al. [180] observed a narrower BSD as temperature increased from 290 K to 351 K. Shafer et al. [183] (Tc = 298–448 K) noticed a decrease in db as long as pc was high compared to the saturation pressure and the evaporation was negligible. The role of evaporation was also discussed by Pohorecki et al [187], who found db to not be dependent on Tc (in the range Tc = 303–433 K). Soong et al. [188] reported a decrease in db when the temperature increased from 293 K (db about 1.5 mm) to 538 K (db about 0.4 mm). The reader should also refer to the section concerning viscous media for an insight into the influence of the liquid viscosity over db.

2.4. Local Flow Properties

Local flow properties (i.e., the liquid and gas velocities, the local void fraction, etc.) provide an insight into the bubble column fluid dynamics, which is needed to characterize the mass transfer phenomena [274]. When considering the local void fraction, we refer to the local value of ɛG, which is a function of both the radial and axial positions in the bubble column [275]. The axial and radial variation in ɛG generate pressure changes, resulting in liquid flow recirculation. Therefore, the investigation of the local void fraction profiles provides an evaluation of the bubble column liquid phase recirculation [276]. The magnitude of the void fraction radial gradients and liquid velocity driven by the gas phase depend on UG, UL, the column design, the phase properties and the operating conditions. A review of the experimental data concerning the local void fraction profiles have been presented by Joshi et al. [276]. In general, three kind of profiles are found in the literature: wall peaked, flat and center peaked. In the homogeneous flow regime (and considering batch or co-current conditions), center peaked profiles occur because a large number of larger bubbles or agglomerates rise at a markedly higher velocity than smaller ones, and thus, they transport most of the gas, as reported by Besagni and Inzoli [34,46]. On the other hand, a wall peaked profile is due to a large number of small bubbles. This behavior is caused by the lift force, which changes its sign (for the air-water case, at db = 5.8 mm), thus pushing the small bubbles towards the wall. This behavior is well known in the literature and was discussed by Tomiyama et al. [277] and Lucas et al. [278]. Increased gas flow rates resulted in greater profile curvature from the column wall towards the center as well as higher void fractions [34,46,125,276]. In particular, the existence of a pronounced radial ɛG profile is among the main characteristics of the heterogeneous flow regime, which is characterized by strong liquid recirculation. Indeed, in this flow regime, the formation of “coalescence-induced” bubbles at higher gas flow rates leads to the above-mentioned increased curvature of the radial profiles. Conversely, flat void fraction profiles generally occur in the homogeneous flow regime using “fine gas spargers” under controlled conditions, as detailed by Mudde et al. [13]. In the literature, a large number of liquid circulation models have been proposed, for example, by Wu et al. [279], Nassos and Bankoff [280], Ueyama and Miyauchi [281] and Luo and Svendsen [282]. As stated before, the liquid velocity and liquid recirculation are strictly related to the local void fraction profiles. Also, the gas phase velocity is related to the local void fraction profile by means of the bubble size distribution.

2.5. Interfacial Area

The interfacial area (ai) is one of the most important parameter for multi-phase reactors. Like the gas holdup and the BSD, it depends on the geometry, operating conditions and the phase properties. The specific interfacial area and εG are related with:
a i = 6 ε G d e q
Besagni et al. [12], based on extensive experimental investigations of bubble sizes and gas hold-ups, obtained the results displayed in Figure 28. These data are a further confirmation of the above-discussed relationship between the liquid phase properties and the bubble column fluid dynamics.
In the literature, some correlations have been presented and have been compared by Besagni et al. [12]. The correlation proposed by Van Dierendonck et al. [283] reads as follow:
a i = 6 C ( σ ρ L g ) 1 / 2 ( μ L U G σ ) 1 / 4 ( ρ L σ 3 g μ L 4 ) 1 / 4 ε G
where C = 2.5. In the case of electrolyte mixtures, C = 1.45.
The correlation proposed by Gestrich and Krauss [284] takes into account the bubble column aspect ratio and reads as follows:
a i = 26 A R 0.3 ( ρ L σ 3 g μ L 4 ) 0.03 ε G
The correlation proposed by Akita and Yoshida [285] takes into account the bubble column diameter and reads as follows:
a i = 0.23 d c ( g d c 2 ρ L σ ) 1 / 2 ( g d c 3 ρ L 2 μ L 2 ) 0.12 ( U G 2 g d c ) 1 / 4 ε G
When εG ≤ 0.14, Equation (49) is simplified as follows:
a = 1 3 d c ( g d c 2 ρ L σ ) 1 / 2 ( g d c 3 ρ L 2 μ L 2 ) 0.1 ε G 1.13
Besagni et al. [12] proposed a modification of Equation (49) to take into account the bubble column aspect ratio. The proposed correlation, validated against a large set of experimental data, reads as follows:
a i = 0.23 d c A R 0.3 ( g d c 2 ρ L σ ) 1 / 2 ( g d c 3 ρ L 2 μ L 2 ) 0.12 ( U G 2 g d c ) 1 / 4 ε G 0.6136

2.6. The Mass Transfer

This section aims to discuss the underlying phenomena, theories and correlations to describe the mass transfer rate (kLa). It is worth noting that kLa is computed as the product of two parameters: (a) the liquid phase mass transfer coefficient kL; and (b) the gas–liquid interfacial area (ai). Accordingly, Martìn et al. [286] stated that the mass transfer rate is mainly determined by two mechanisms (viz. the bubble oscillations, related to the concentration profiles around the bubble, related to kL, and the contacting area, a). When considering previous literature, it is worth noting that bubble columns are mostly employed in slow reaction–absorption applications where the interphase mass transfer resistance on the gas side might be considered negligible compared with the gas–liquid side (kL) [287]. Generally speaking, up to now, only a few theoretical correlations for kLa prediction in two-phase bubble columns [288], numerical models [289,290,291,292] or correlation-based predictions [139,293] have been used.

2.6.1. Physical Phenomena and Approaches

As previously mentioned (see Figure 2), the mass transfer phenomena occur across the bubble interface; thus, its correct estimatation relies on the precise understanding of the motion of bubbles in the liquid phase and the motion of the liquid phase around the bubbles. In this regard, the interfacial area and the shape of the interface are the fundamental parameters and details to correctly model. Generally speaking, interfacial turbulence promotes intensive mass transfer (in this respect, the interaction of micro-eddies and particles leads to an increase in turbulence intensity in the bulk phase [294]). The interested reader may refer, for example, to Lochiel and Calderbank [295] who proposed a discussion concerning the relationships between the mass transfer coefficient, the bubble shape, the steady state and the unsteady state phenomena. Different theories are available to explain the mass transfer rate (i.e., the film theory, the penetration theory; see the surveys in refs. [288,296,297]). In the film theory, the concentration distribution is linear and one-dimensional; the coefficient of mass transfer in this special case is proportional to the diffusion coefficient and inversely proportional to the thickness of the film. Conversely, the Higbie’s penetration theory [298] assumes unsteady state absorption of the dispersed phase by a fluid element adjacent to the surface and moving at a uniform velocity during the mass transfer process. It is worth noting that, in this approach, an unhindered flow situation may be observed when considering the larger bubbles [299]. In this approach, the contact time is usually defined as the ratio of db to bubble rise velocity; it characterizes the residence time of liquid elements at the interface and is used to estimate the liquid phase mass transfer coefficient (see, for example, refs. [300,301]); it is also worth mentioning that Nedeltchev et al. [288,296] assumed that the contact time depends on both the bubble surface and the rate of surface formation. Owing to the uncertainties in the estimation of the contact time, the penetration theory is inapplicable in different practical applications (e.g., turbulence may determine the renewal of the fluid layers surrounding the bubbles). It is also worth noting that Kawase et al. [302] proposed a semi-theoretical approach based on Higbie's penetration and Kolmogoroff's turbulence theories. Recently, Nedeltchev [297] proposed a modified version of the penetration theory that can be used to correctly predict the mass transfer coefficient in both the homogeneous flow regime and the transition flow regime.

Influence of the Bubble Column Design

Gas sparger opening. It is not surprising that the gas sparger has a large influence on kLa [24]; indeed, depending on the gas sparger openings, the prevailing flow regime changes (as previously discussed and observed by Besagni et al. [14,37]). The influence of kLa on the gas sparger openings has been observed, for example, by Koide et al. [138] and is displayed in Figure 29. kLa increases with a decrease in d0 and increases (less than linearly) with an increase in εG. The increase in the mass transfer with a decrease in the gas sparger opening is related to the prevailing flow regime determined by the gas sparger [14,37,45]—decreasing d0 moves the prevailing BSD towards a lower bubble equivalent diameter and thus, increases the interfacial area. Hence, a good distribution of bubbles across the reactor increases the efficiency of the gas flow rate on kLa [286,303]. The relationship between kLa and εG is related to the shape of the gas hold-up curve, depending on the flow regime; indeed, the bubble column fluid dynamics are highly influenced by the sparger design in the homogeneous flow regime, but not in the heterogeneous flow regime [28,111]. From these observations, it is clear that highly efficient bubble columns should be operated in the homogeneous flow regime, rather than in the heterogeneous flow regime, where the dispersed phase is transported through the column as large “coalescence-induced” bubbles. These “coalescence-induced” bubbles have a lower residence time, leading to a decreased conversion process. In other words, the further enhancement of εG in the heterogeneous flow regime is marginal and certainly not commensurate with the imposed increase in gas flow rate.
Column diameter. Deckwer and Schumpe [287] found that the dependence of kLa on the column diameter exists only for column diameters smaller than 0.6 m. Conversely, Akita and Yoshida [47] (Figure 30 and Figure 31) found that the mass transfer coefficient is related to the bubble column diameter up to a diameter of approximately 0.15 m, which is in agreement with the “large diameter” concept described in Equation (1) and the experimental results of Vandu and Krishna [304] (Figure 32).

Influence of the Bubble Column Operating Conditions

In this section, the relationships between the operating parameters and kLa are discussed. In particular, the gas flow rate and the operating pressure are considered and commented on. It is known that the relationship between kLa and UG is well described by Equation (52):
k L a i   α   U G n
where n can be between 0.7 and 0.92 [285,302,305,306]. Thus, the relationship between kLa and UG is less than linear, in agreement with the considerations proposed in Section 2.6.1—the relationship between kLa and εG is related to the shape of the gas hold-up curve, depending on the flow regime; indeed, in the transition/heterogeneous flow regimes, the dispersed phase is transported through the column as large “coalescence-induced” bubbles, having a lower residence time and thus, a lower mass transfer rate. This observation is in agreement with the experimental observations reported by Letzel et al. [170], Kang et al. [179] and Ozturk et al. [173] (Figure 33, Figure 34 and Figure 35). On the other hand, it has been observed that increasing the operating pressure increases kLa, owing to the decrease in bubble size (as previously stated). Figure 36 proposes a summary of previous literature concerning the relationship between kLa and UG.

Influence of the Liquid and Gas Phase Properties

As previously stated, the liquid phase viscosity plays an important role in kLa. Indeed, the liquid viscosity, if above the maximum value dictated by the “dual effect”, increases the mean diameter of the bubbles in the dispersion, thus reducing kLa. (as observed by Kang et al. [179]). In this condition, the lather bubbles are stable in the flow at higher viscosities. In addition, the liquid viscosity also decreases the liquid diffusivity (DL) [299]. In the case of oxygen transfer, DL is proportional to μL−0.57 [173]. It is worth noting that some authors have also considered the influence of the gas viscosity proposed by [306]. Finally, Ozturk et al. [173] (Figure 37 and Figure 38) and Gopal and Sharma [106] (Figure 39) studied the influence of the gas phase on kLa and observed a lower influence compared with the above-mentioned operating parameters.

2.6.2. The Mass Transfer Correlations

In the last few decades, many correlations for mass transfer prediction have been proposed (see the literature survey proposed in ref. [308] and the discussion in refs. [309,310,311]); for example, the correlation of Schumpe [18] reads as follows:
k L a = K U G 0.82 μ e f f 0.39
where K = 0.063 (water/salt solution), K = 0.042 (water, 0.8M Na2SO4). Most of the correlations [24,47,285] for kLa prediction in gas–liquid bubble columns neglect the effect of the bubble column aspect ratio; in this regard, Zhao et al. [312] proposed empirical correlations that consider the effect of liquid height on kLa. The correlations proposed by Akita and Yoshida [47,285] (Equation (54)) and by Shah et al. [24] (Equation (55)) read as follows:
( k L a ) d c 2 D G , L = 0.6 ( ν L D G , L ) 0.5 ( g d c 2 ρ L σ ) 0.62 ( g d c 3 ν L 2 ) 0.31 ε G 1.1
( k L a ) = 0.467 U G 0.82
where DG,L is the diffusivity coefficient between the gas/liquid phases. In their empirical correlation, Öztürk et al. [173] used the surface-to-volume mean bubble diameter as a characteristic length rather than the column diameter:
( k L a ) d b 2 D G , L = 0.62 ( μ L ρ L D G , L ) 0.5 ( g ρ L d b 2 σ ) 0.33 ( g ρ L 2 d b 3 μ L 2 ) ( U G g d b ) 0.68 ( ρ G ρ L ) 0.04
Finally, for the sake of clarity, other correlations are listed below:
  • Kawase and Moo-Young, 1987 [302]:
    ( k L a ) d c 2 D G , L = 0.452 ( ν L D G , L ) 1 / 2 ( d c u G ν ) 3 / 4 ( g d c 2 ρ L σ ) 3 / 5 ( U G 2 D T g ) 7 / 60
  • Hikita et al., 1981 [306]:
    ( k L a ) u G g = 14.9 ( U G μ L σ ) 1.76 ( μ L 4 g ρ L σ 3 ) 0.248 ( ρ G ρ L ) 0.243 ( μ L ρ L D G / L ) 0.604
  • Kang et al., 1999 [179]:
    ( k L a ) = d c 10 3.08 ( d c U G ρ G μ L ) 0.254

3. The Experimental Techniques

A comprehensive review on the experimental techniques for multi-phase reactors was provided by Boyer et al. [313] and by Jakobsen [314], to whom the interested reader may refer for all the details concerning the broader framework of the measurement techniques for multi-phase flows. In this section, we provide an overview of the measurement techniques for both the local-scale and global-scale fluid dynamic parameters discussed in the previous section.

3.1. The Flow Regimes

It is well known that the correct definition of an approximate transition point helps in understanding and modeling the fluid dynamics behavior in multi-phase reactors [89]. Different methods have been presented over the last few decades, as discussed by Shaikh and Al-Dahhan [102], Nedeltchev and Shaikh [26] and Nedeltchev [27]. The most common methods employed are statistical methods (by interpretation of the ɛG-UG curve), the swarm velocity [7,11,34,46,51,52,53,75,76,89,91,229,315,316] and the drift flux [7,11,34,38,46,51,53,75,76,229,316,317,318] approaches. These methods are based on the analysis of ɛG data. Other flow regime identification methods are the fractal [319], wavelet [320,321], Hurst’s [322,323], spectral and nonlinear chaos [93,320,324,325,326,327,328,329,330,331,332,333] and Kolmogorov entropy [332,333,334] approaches. Some authors have used methods based on the Shannon entropy, which measures the degree of indeterminacy in a system [335,336]. Nedeltchev identified the flow regimes based on the information entropy theory [26]. Finally, the detection of the flow regimes using local measurements was demonstrated by Shiea et al. [337]. The interested reader should refer to the recent study proposed by Tchowa Medjiade et al. [334] (viz. power spectral density, standard deviation, fractal analysis, Kolmogorov entropy); they found systematic differences between the various methods. In the current authors’ opinion, future studies should be devoted to proposing a comprehensive approach that is able to take into account all the possible flow regimes, without the possibility of subjective evaluation.

3.2. The Gas Hold-Up

The most common method, for measuring ɛG is the bed expansion technique [3]. This method is based on the measurement of the liquid free surface before and after aeration. Another well-known method is based on the measurement of the differential pressure between two or more points in the column [80,86,114,116,122,123,125,126,135,141,170,179,194,198,209], under the hypothesis of negligible acceleration and friction pressure losses, as discussed by Leonard et al. [1]. This method has been applied by a large number of authors. For example, Hikita et al. [80] determined ɛG by measuring the static pressure at three points in the column at 0.25 m intervals, the lowest being 0.15 m above the gas sparger. Another method is the dynamic gas disengagement proposed by Schumpe et al. [18], which may also be used for investigating the structure of ɛG (in terms of “coalescence induced” and “non-coalescence induced” bubbles) and for investigating the flow regime transition.

3.3. The Bubble Size Distribution and Shape

Different non-intrusive and intrusive techniques have been proposed for measuring bubble shape and bubble size distribution [338,339,340,341,342,343,344,345,346,347,348,349]. Non-intrusive measurement techniques do not influence the fluid dynamics and for this reason, image analysis has attracted growing attention in recent years [350]. In the literature, image analysis has been applied to small-scale [242,351] and medium-scale bubble columns [183]; conversely, there is a lack of studies concerning bubble size distribution in large diameter bubble columns and large scale multi-phase reactors. Indeed, image analysis techniques are still limited in the resolution of large void fractions, highly unsteady flows and large bubble clusters [352]. Additionally, there are well-known issues associated with overlapping—if ɛG exceeds 1%, more than 40% of the bubbles are overlapping [353,354]. Despite the proposed methods to deal with overlapping bubbles by different studies [242], no agreement has been found so far (i.e., some approaches may cause a reduction in the bubble sample size and/or an underestimation of the bubble diameter). Furthermore, by using the classical image analysis methods, only projected bubble images can be obtained; despite some proposals against this issue [355,356], a solution is far from being reached. For this reason, the use of 2D projected images is a common way of analyzing the bubble images [242,244,352,357,358,359]. Concerning the approximation of the ellipse of the bubbles, Lage and Espósito [358] have stated that the error in the measurement of each axis of the ellipse is approximately 6%. In addition, if considering the error introduced by the hypothesis of oblate spheroid and the optical distortion, Lage and Espósito have estimated that the experimental error in the determination of deq is in the range of 10–15%. Finally, when investigating bubble size distributions, the number of bubbles that need to be sampled to achieve a reliable BSD should be considered [360]. Various studies have sampled different numbers of bubbles—in the range of 50 and 300 [38,244,358,361,362,363], and a sensitivity analysis on this issue has been presented in our previous paper [53].

3.4. The Local Flow Properties

Wire mesh sensors and the tomography of gamma rays, X-rays, electric or ultrasonic waves have also been used in previous literature. Boyer et al. [313] and Jakobsen [314] proposed a complete description and detailed discussion of these techniques. Hernandez-Alvarado et al. [364] compared many experimental techniques to evaluate the local flow properties in bubble columns; they found that pressure transducers and gamma densitometry were able to produce reliable measurements, regardless of the prevailing flow conditions. Another comparison between experimental techniques was presented by Singh et al. [365]. Optical probes were found to underestimate local void fractions. Conversely, electrical resistance tomography was found to be the least reliable method. Finally, the experimental findings regarding the wire mesh method were found to be highly related to the bubble size and mesh spacing. Generally speaking, needle, heat transfer and ultrasound probes are among the most common methods applied for studying the local flow properties in bubble columns [313]. Heat transfer probes are capable of simultaneously measuring the local void fraction and liquid velocity. Ultrasound probes are capable of measuring the local void fraction, bubble diameter and velocity. Needle probes are capable of simultaneously measuring the local void fraction, bubble chord lengths and rise velocities. In particular, two types of needle probes have been previously used for measurements in bubble columns: optical fibers and impedance/conductive probes. Optical fibers and impedance probes operate based on the differences in the refractive index or conductivity, respectively, of the liquid and gas phases. Signal fluctuations due to phase changes at the probe tip allow the measurement of local properties; these devices were developed to measure the rise velocities along with the other local properties [337,365,366,367,368,369,370,371]. When considering the experimental error of the needle probes, two parts should be considered: (a) the statistical error associated with the measuring time (proportional to the square root of the measuring time); (b) the bias error due to the difficulties of piercing a bubble at the bubble edge [372] (viz. the blinding effect, drifting effect and the crawling effect). A complete discussion of these issues has been proposed in our previous paper, to which the reader may refer to, as well as previous literature (i.e., see refs. [127,355,373,374,375,376,377,378]). Besides the local void fraction and rise velocities, probes provide chord length distributions (CLDs). Several authors have proposed methods to relate CLD to corresponding BSD. A process that deduces BSD from CLD is called “backward transform”. In contrast, the deduction of a CLD generated from an existing BSD is called “forward transform”. Liu and Clark [379] (assuming ellipsoidal and vertically rising bubbles) proposed a “backward transform” using an analytical relationship between probability density functions for CLD and BSD. Clark and Turton [380] proposed a “forward transform” to infer the CLD from the BSD for different bubble shapes. Hu et al. [381] used a “forward transform” to obtain the CLD from the log-normal and uniform BSDs. Al-Oufi [363] proposed an algorithm based on a double transformation (a backward and a forward transformation). This approach has been also detailed and applied in the dissertation of Carrasa [382]. Rudisuli [383] proposed a Monte Carlo method that simulates the bubble sampling process in the cross-section of the pipe. Hoang et al. [384] decomposed the CLD into sub-distributions which are considered to be the CLDs of bubble groups. These CLDs are converted into BSDs using the approach of Liu and Clark [379], and finally, the whole system BSD is constructed. It is important to notice that to relate the chord length distributions to the bubble size distributions, a correlation for the bubble shape is required. Therefore, a correlation between the aspect ratio (φ) and a bubble dimension parameter should be provided. Several attempts have been made in the literature to correlate the aspect ratio to dimensionless parameters (i.e., the Eötvös number, related to the bubble size). However, these correlations are obtained for single rising bubbles (or single drops in liquids [223]) and their use for bubbly flows is questionable. This issue has been deeply considered by Besagni et al. [229], to whom the reader should refer: the use of correct aspect ratio correlations is essential.

3.5. The Mass Transfer

The mass transfer coefficient, as reported by refs. [107,285]), can be determined from experiments involving absorption of a gas (e.g., oxygen or carbon dioxide) into various liquids. Using an experimental column that is operated continuously with respect to the gas flow, and batch-to-batch with respect to liquids, it is possible to write the following mass balance, on the assumption of complete liquid mixing, where *, as a subscript, stands for the equilibrium concentration:
d c j d t = ( k L a ) ( 1 ε G ) ( c j c j )
c j ( t = t i ) c j ( t = t f ) d c j ( c j c j ) = ( k L a ) ( 1 ε G ) t = i t f d t
ln ( c j c j f ) ( c j c j i ) = ( k L a ) ( 1 ε G ) t
( k L a ) = ( 1 ε G ) t ln ( c j c j i ) ( c j c j f )

4. The Modeling Approaches

Numerical modeling of bubble column reactors is a way of predicting the multiphase flow for improving the reactor design and understanding the reactor fluid dynamics. Many phenomenological models have been presented in the literature [281,309,385,386,387,388,389,390,391,392,393,394], but they are limited in providing detailed information regarding the two-phase flow phenomena. On the other hand, computational fluid dynamics (CFD) is a promising method for studying the local and global bubble column fluid dynamics. Among the available modeling techniques, the Eulerian multi-fluid approach is the most common approach for simulating bubble column reactors, as reported in the review of Jakobsen et al. [395]. Different studies have applied the Eulerian–Lagrangian approach [396,397,398,399,400,401] but have still been limited to the simulation of small-scale reactors with low ɛG. It is worth noting that, at present, it is possible to model the flow regimes listed in Section 2.2.1 by using different modeling approaches (see the discussion below); unfortunately, a comprehensive model, able to simulate the whole range of operating conditions in bubble columns, is still missing.

4.1. The Eulerian Multi-Fluid Approach

The Eulerian multi-fluid approach treats each different phase as interpenetrating continua and relies on an ensemble averaging of the multiphase Navier–Stokes equations [402]. Considering an isothermal flow without mass transfer, the URANS governing equations for the k-th phase are as follows:
t ( α k ρ k ) + ( α k ρ k u k ) = 0
t ( α k ρ k u k ) + ( α k ρ k u k u k ) = α k p + ( α k τ ¯ k ) + α k ρ k g + M I , k
The terms on the right-hand side of Equation (9) represent the pressure gradient, the viscous and Reynold stresses, the body forces and the interfacial momentum exchanges between the phases. The above-mentioned model considers non-reactive systems; recently, other authors have proposed modeling approaches for reactive multi-phase flows in bubble columns, to whom the reader should refer [290,291,292]. The last term in the momentum equation comprises several independent physical mechanisms, as follows:
M I , k = F D , k + F L , k + F V M , k + F T D , k + F W L , k
The terms on the right-hand side of Equation (12) represent the drag, lift, virtual mass, turbulent dispersion and wall lubrication forces. The reader may also refer to the work of Vik et al. [292] for an interesting discussion concerning these interphase forces.
The accuracy of the simulations based on this approach is highly dependent on the closure models and on the numerical aspects (i.e., numerical methods, the time step size and the mesh). Following an overview of the advancements and current trends in bubble column simulation using the Eulerian multi-fluid approach is provided. The pioneering work, performed among in 1989 and 1999, reproduced the fluid dynamics in rectangular bubble columns using two-dimensional Eulerian simulations [403,404,405,406,407,408,409,410,411,412]. However, other authors [413,414,415,416] remarked that, for more accurate predictions of the bubble plume oscillation period and the turbulent quantities, three-dimensional simulations are required for both rectangular [413,414,415] and circular [416] columns. In addition, high order discretization schemes should be applied, regardless of the closure models implemented [417,418,419,420,421]. For example, Oey et al. [421] reported that numerical diffusion may prevent the transient nature of the two-phase flow emerging. In addition, beside the accuracy of discretization schemes, mesh resolution is a fundamental parameter in determining the capability prediction of the approach—despite the number of mesh sensitivity studies performed in the past, the proper mesh size to adopt in a bubble column reactor simulation is still an open debate [422,423,424]. It is worth noting that the mesh size also depends on the turbulence modeling approach implemented. Large eddy simulations (LES, [425]) of bubbly flows require a mesh size within both a higher and a lower bound in order to get a proper filter cut-off [426,427]. Conversely, RANS (Reynolds-averaged Navier–Stokes) simulations are less restrictive on the mesh size [10,414,420,428,429,430]. Besides the numerical aspects, proper turbulence modeling is important for the accuracy of the simulations; multi-phase turbulence models are derived from their single-phase equivalents and terms modeling inter-phase interactions are added to the transport equations of the turbulence model (see refs. [413,431]). In this respect, the multi-phase equivalent of the standard k-ε model is widely used [413,414,415,428,432,433,434,435]. Comparisons between the k-ε model and LES simulations have shown that similar performances are obtained in terms of average quantities; conversely, more accurate fluctuating quantities are achievable through LES [436,437,438,439], owing to the isotropic turbulence hypothesis of the k-ε model. The SST k-ω model has proven to be slightly superior to the k-ε model for simulating upward bubbly flow [440,441] and vertical pipes [10,430,442,443,444,445,446,447]. It is worth noting that suitable prediction and selection of inlet turbulent boundary conditions are needed for reliable predictions [448]. In this framework, models based on the RSM (Reynolds Stress Models) approach seem promising [449,450,451,452] for improving the numerical prediction of the turbulence quantities to be used as inputs for bubble coalescencence and break-up models. In addition, suitable models that take into account the bubble induced contribution should be selected and developed [453,454,455]; for example, recent studies aimed to calibrate this contribution based on DNS (Direct numerical simulations) studies [456]. As previously mentioned, correlations for interfacial forces are implemented to model the inter-phase momentum exchanges (i.e., see the screening of interfacial forces in ref. [457]). The drag force influences ɛG and the mean residence time of the disperse phase [420,439]. The lift force has three components, but the largest component acts perpendicular to the main bubble flow direction; in bubble columns, this means the radial direction. In particular, this force is responsible for the migration of small bubbles toward the column walls or the center of the pipe, depending on the bubble shape and size [277,278]. The turbulent dispersion force spreads out large bubbles from the pipe center and modulates peaks of small bubbles near the pipe walls [458]. Its magnitude is also high near distributor inlets, supporting the modeling of bubble dispersion near coarse gas spargers [429]. The wall lubrication force models the lift force close to the wall, thus pushing the bubbles away from it. Rzehak et al. [459] compared various formulations applied to vertical bubbly flow in a pipe and concluded that the inclusion of this force into the model is fundamental. The virtual mass force arises from the relative acceleration of an immersed moving object to its surrounding fluid; this force is often found to be negligible in bubble column simulations [421,428,437,439,449,460], and different studies have neglected it [420,430,440,441,446,450,458,461,462,463,464,465,466,467,468,469]. Recently, Ziegenhein et al. [10] demonstrated that the virtual mass force has an influence on the prediction of the turbulence intensity at higher flow rates. It is clear that an independent validation of each single force is not possible; for this reason, a complete set of interfacial forces should be used [9,10,443,444,445,447,459,470,471,472,473], as discussed by [443] and recently validated against a large set of experimental data [474].
Most of the interfacial force correlations require, as an input, the average equivalent diameter of the bubbles; in this regard, two approaches can be used: (a) a constant bubble equivalent diameter (taken from experimental data or correlations); or (b) implementation of a population balance model (please, refer to the next section for further detail) that predicts the local bubble size distributions using coalescence and breakage kernels [433,475,476,477,478,479]. The former case is typical of the mono-dispersed flow regime [480]. The latter case is typical of the pseudo-homogeneous flow regime [481,482]; in this case, a continuous approach or a discrete approach can be used. The former approach has been recently proposed by Vik et al. [292], where a continuous solution of the density function is obtained rather than a discrete solution. Moreover, both the bubble velocity, composition and temperature are all continuous functions of the bubble size. Hence, an infinite distinction is used between the small and large bubbles in an inhomogeneous population balance model. In the latter approach, the gas phase is subdivided into different bubble size classes along with a single (“homogeneous population balance model”) or multiple (“inhomogeneous population balance model”) gas velocity fields, depending on the desired level of distinction between small and large bubbles [465]. Homogeneous population balance models have been applied to bubble column simulations and upward bubbly flows by several authors [428,433,440,441,461,462,463,466,475,483]. On the other hand, Krishna et al. [484] introduced one of the first uses of two velocity groups to distinguish the dynamics of small and large bubbles. This approach has been also presented in other works [483,485,486,487]. The model, however, did not implement a population balance model, but rather, a constant bubble equivalent diameter for each group and the non-drag forces were neglected. More recently, Ziegenhein et al. [10] used two velocity groups for the gas phase, following the proposal of Krepper et al. [488], which has also been used in several studies [430,435,442,444,446,447,458,465,489]—the two velocity groups for the gas phase are computed by slitting the original distributions at the diameter for which the lift coefficient changes its sign. It is worth mentioning the study of Xu et al. [483], which compared the above-mentioned approaches and found that the best performances are given by the “inhomogeneous population balance model”. Recently, Besagni et al. [481] studied the pseudo-homogeneous flow regime in large scale bubble columns and compared different numerical approaches: (i) the fixed polydispersed formulation (using the two- and four-class approaches); and (ii) coalescence and break-up closures. The results suggest that the inclusion of coalescence and break-up closures are essential to simulate the bubble column fluid dynamics.
It is worth noting that suitable boundary conditions should be provided to obtain realistic solutions of the problem—i.e., wall, inlet, outlet, and symmetry conditions. The wall boundary conditions model the interaction of the dispersed/continuous phase with a continuum material (i.e., a solid phase); at the walls, the gas shear stress and the tangential components of the liquid velocity should tend towards zero. Inlet and outlet boundary conditions aim to provide boundaries to the numerical computational domain, and they represent the effects of the neglected part of the whole domain in the considered spatial discretization. It is worth noting that, when developing a numerical model, proper selection of the boundary conditions is essential for reaching reliable numerical solutions (i.e., some reliable assumptions should be provided when modeling inlet conditions, i.e., fully developed flow conditions). It is worth noting that inlet conditions are particularly important; in practice, we generally know the superficial velocities but not the local volume fractions and the local phase velocities. Normally, the local volume fractions are estimated roughly, and the local velocities are then computed from the superficial velocity definition. It usually follows that steep gradients occur close to the inlet, as the solution of the Navier–Stokes equations in the first point predicts a solution far from the estimated profiles. In addition, it should be noted that, from a practical point of view, the convective terms in the gas phase momentum equation are generally very small compared to the pressure, drag and gravity terms. This induces convergence problems, as the gas velocity at the first point within the domain is hardly related to the boundary condition, and the finite number representation of the computer may prevent convergence (see ref. [490]). A typical outlet condition concerns a constant pressure, which requires vanishing tangential velocity components of both the gas and the liquid phases. Finally, symmetry conditions aim to truncate the numerical domain. For transient calculations, the initial conditions should be provided as well.

4.2. A Focus on the Population Balance Modeling

4.2.1. The Approach

An uncertainty in bubble column design and scale-up arises from the lack of understanding of the phenomena governing bubble size distributions (BSDs) and, consequently, the column fluid dynamics and the interfacial area. The bubble size distributions depend on the many phenomena occurring in the bubble column: the balance between the coalescence and break-up rate, the pressure change, the gas–liquid mass transfer. In particular, the bubble size distribution is considered, mainly as a consequence of the coalescence and break-up phenomena occurring in the bubble column. Theoretically, based on the knowledge of these phenomena, the BSD could be determined a priori. Based on the BSD of the system, the whole column fluid dynamics could be predicted. However, because of the unsatisfactory understanding of the mechanisms that govern break-up and coalescence, no broadly applicable model is available. In bubble columns, the initial bubble size distribution is determined by the formation of the bubbles at the gas sparger level. This bubble size distribution may not be stable due to changes by break-up and/or coalescence mechanisms and determines the “developed” (equilibrium) BSD existing in the bubble column. Since the interfacial area concentration changes with the variation in the bubble number density due to coalescence and break-up phenomena, a population balance model can be used to provide a statistical formulation to describe the dispersed phase in multi-phase flow [475,491,492,493,494,495,496]. In the next sections, the fundamentals of this method and the governing equations are discussed, and then the coalescence and break-up phenomena are presented. Herein, the basis for understanding Chapter 5 (where a population balance model is formulated and implemented) is given. For further detail, the reader should refer to the review of Liao and Lucas concerning coalescence [215] and break-up [214] phenomena and modeling.

4.2.2. The Governing Equations

A population balance model can be described by a transport equation derived from the Boltzmann statistical transport equation. It reflects particles entering or leaving a control volume via several mechanisms. The bubble number density transport equation is often referred to as the Population Balance Equation (PBE) [215]:
t n ( x , V b , t ) + z [ n ( x , V b , t ) u b ( x , V b ) ] + V b [ n ( x , V b , t ) t V b ( x , V b ) ] = S ( x , V b , t )
where n ( x , V b , t ) is the bubble number density distribution function and specifies the probable number density of bubbles at a given time (t), in the spatial range, d ( x ) , about a position, x , with bubble volume between Vb and Vb + d(Vb). ub is the local velocity of bubble volumes between Vb and Vb + d(Vb) at time t. Finally, S ( x , V b , t ) is a source term, which reads as:
S ( x , V b , t ) = S c + S b + S p h + S p + S m + S r
where Sc, Sb Sph, Sp, Sm and Sr are the bubble source/sink terms due to coalescence, break-up, phase change, pressure change, mass transfer and reaction, respectively.
The coalescence source term, Sc, reads:
S c = 1 2 0 v Γ ( V b V b , V b ) f ( x , V b V b , t ) f ( x , V b , t ) d V b f ( x , V b , t ) 0 Γ ( V b , V b ) f ( x , V b , t ) d V b
where the first term is the birthrate of bubbles of volume Vb due to the coalescence of bubbles of volume, Vb − Vb and Vb; the second term is the death rate of bubbles of volume Vb due to coalescence with other bubbles. Finally, Γ(Vb, Vb) is the coalescence rate between bubbles of volume Vb and Vb.
The break-up source term, Sb, reads:
S b = v m ( V b ) Ω ( V b ) P ( V b , V b ) f ( x , V b , t ) d V b Ω ( V b ) f ( x , V b , t )
where the first term is the birthrate of bubbles of volume Vb due to the break-up of bubbles with volumes larger than Vb; the second term is the death rate of bubbles of volume Vb due to break-up. Finally, Ω(Vb) is the break-up rate of bubbles of volume Vb, m(Vb′) is the mean number of daughter bubbles produced by break-up of a parent bubble of volume Vb′ and P(Vb, Vb′) is the probability density function of daughter bubbles produced upon break-up of a parent bubble with volume Vb′.
Neglecting the interfacial mass transfer, the reaction contribution, the phase variations and the changes due to the pressure gradients, the coalescence and break-up rates are the only phenomena occurring. Considering a steady state, it follows that:
u b , i n i z = S i ( x , V b ) = S c + S b
Which can be written in terms of the bubble diameter:
u b , i n i z = S i ( x , d e q ) = S c + S b
Sc and Sb are determined by modeling the bubble break-up and coalescence rates.

Bubble Coalescence Phenomena and Modeling

Bubble coalescence results from collision between bubbles. Attention may be restricted to binary collisions as the probability of interactions involving more than two bubbles is significantly lower in the homogeneous flow regime. Collision between two bubbles requires a non-null velocity difference between the bubbles [495]. The collision may be a consequence of at least five mechanisms (Figure 40) [215]: (i) different rise velocity (buoyancy); (ii) mean velocity flow gradient; (iii) turbulent fluctuations of the carrier phase; (iv) bubble capture in an eddy; and (v) bubble–wake interactions. The collision between bubbles can result either in coalescence or in bouncing. Hence, to model the coalescence rate, one has to consider both the frequency of collisions (the “collision frequency”) and their efficiency of causing coalescence (the “coalescence efficiency”).
Coalescence models have been extensively studied over the past decades, and a variety of models have been published [215]. A first class of models is the empirical-based models, based on the modeling of the coalescence rate (without modeling separately “collision frequency” and the “coalescence efficiency”) by using functions (i.e., power law) with parameters that can be adjusted to fit a set of experimental data. These models mainly depend on the experimental configuration and operating conditions of the data used to calibrate the model parameters. For this reason, the application of these models to a broader range of operating conditions is questionable. Another class of models is the “physical (or phenomenological)-based models”, where the coalescence rate is considered equal to the products of the “collision frequency” and the “coalescence efficiency”. The collision frequency is modeled by summing the contribution of the different collision phenomena. The “coalescence efficiency” can be modelled by three different approaches: (i) empirical approaches; (ii) physical approaches based on the “energy model; and (iii) physical approaches based on the “film drainage model”. An empirical approach is the approach velocity model of Lehr et al. [497] based on experimental data, showing that a small approach velocity leads to higher coalescence rates. This criterion is the opposite of the physical energy model of Howarth [498] which predicts coalescence when the kinetic energy of two colliding bubbles is larger than a critical value. However, the physical film drainage model, firstly proposed by Shinnar and Church [499], is the most common approach used to model the coalescence rate. The coalescence process described by this model is structured into three steps:
  • collision between two bubbles trapping a liquid film;
  • drainage of the liquid film;
  • film rupture and coalescence.
The last step is reached if the contact time is larger than the drainage time (the flow fluctuations limit the bubble–bubble interaction time). Different models have been presented depending on the model hypothesis (i.e., non-deformable bubble surfaces or deformable surfaces with (i) immobile; (ii) partially mobile; or (iii) fully mobile interfaces).

Bubble Break-Up Phenomena and Modeling

A bubble moving through a continuous phase experiencesstress that acts to deform it; this stress is counteracted by the surface tension. If the deforming stress is strong enough to overcome the restoring effect of surface tension, the bubble will break-up, generating two or more daughter bubbles. A break-up model considers two sub-models: the “break-up rate” model and a “daughter bubble” distribution.
The “break-up rate” model considers the break-up mechanisms. In the case of turbulent gas–liquid systems, the deforming hydrodynamic stresses may be caused by at least four mechanisms (Figure 41) [214]: (i) shear stresses (viscous forces); (ii) turbulent fluctuations/turbulent stresses (collision with turbulent eddies); (iii) interfacial instability; and (iv) interfacial stresses [496]. In the following text, these mechanisms are briefly outlined.
Break-up due to shear stresses (i.e., when in a wake region or inside a turbulent eddy) may occur whenever the particle is subject to velocity gradients around its surface. The turbulence in the carrier phase causes pressure fluctuations alongside the interface and bubble–eddy collisions. It is worth noting that most kernels are restricted to the inertial range of turbulence, an extension to the entire spectrum of turbulence is described in refs. [493,494]. Hence, the bubble is stretched in one direction and eventually undergoes rupture. Interfacial instabilities are classified into Taylor–Rayleigh or Kelvin–Helmholtz instabilities: (i) Taylor–Rayleigh instability arises whenever a lighter fluid is accelerated into a heavier fluid; (ii) Kelvin–Helmholtz instability occurs whenever the velocity difference at the interphase of two fluids is sufficiently large. In this respect, Ishii and Kojasoy [500] provided a correlation for the maximum stable bubble size, dbmax:
d b max = 40 σ g ( ρ L ρ G )
dbmax = 10 cm in air-water systems in ambient conditions (therefore, interfacial instabilities are seldom considered). Finally, interfacial stresses must be considered—as the bubble rise velocity increases, the shearing-off events gain importance, and the interfacial shear force and drag force cause the shearing-off of small bubbles at the rim of large bubbles. Likewise, when the interphase relative velocity becomes too high and thus, the interfacial force is high enough, the bubbles become unstable and start to stretch in the direction of the destroying force (i.e., in counter-current mode). Generally speaking, in most cases, the carrier phase is turbulent; therefore, only the dominant break-up mechanism due to the turbulent fluctuations is considered [214]. Break-up models should also consider the distribution function of the daughter bubble size [501]. Some examples of daughter bubble size distributions are (i) statistical distribution (i.e., normal or the uniform); (ii) empirical distribution; or (iii) phenomenological distribution [214]. In this regard, the reader may refer to the experimental high-speed imaging of Solsvik et al. [502]: they conducted in an attempt to understand the break-up cascade; in particular, they found that the assumption of binary breakup in the PBM approach is acceptable only if the initial breakup is analyzed.

5. Conclusions, Guidelines and Outlooks

5.1. Summary of the Literature Survey

In this paper, we presented a literature review on bubble column fluid dynamics at different scales and deeply analyzed the flow regimes, flow regime transitions and local and the global fluid dynamics parameters. We also presented experimental techniques for studying the global and local fluid dynamic properties, and we discussed the modeling approaches for studying the global and local bubble column fluid dynamics. Taking into account all the different results discussed, it is clear that the complete description and modeling of bubble column fluid dynamics rely on the knowledge of the phenomena at different scales. In this respect, a multi-scale approach should always be considered when proposing future experimental investigations. In the current author’s opinion, the fundamental parameter for understanding and modeling the bubble column fluid dynamics is the prevailing bubble size distribution in the systems. In this regard, the bubble size distribution is imposed by the gas sparger and the operation modes (i.e., the gas flow rates) and it changes accordingly with the constraints given by the system and governs the bubble column fluid dynamics. In particular, a change in the phase properties/operating conditions would affect bubble interface properties (related to the coalescence suppression/enhancement mechanisms), which modifies the bubble size distribution and shapes, thus stabilizing/destabilizing the homogeneous flow regime and ultimately, increasing/decreasing ɛG. The bubble column design parameters influence the fluid dynamics because of the boundary conditions, as well as the end-effects (i.e., wall or outlet effects). Similarly, appropriate modeling approaches should be selected by taking into account the prevailing bubble size distributions in the system.

5.2. Guidelines

Based on the literature survey proposed in this paper, some guidelines to be taken into account in future studies are proposed:
  • Different studies have investigated, in the few last decades, either local or global fluid dynamics properties; unfortunately, the studies concerning both local and global fluid dynamics properties are still limited in number. In this respect, experimental studies should always provide a multi-scale evaluation of bubble column fluid dynamics (i.e., by studying, at least, both gas hold-up and bubble size distribution);
  • Experimental studies should always provide detailed information concerning the main bubble column design criteria (as listed in Section 2.3.2) in order to relate the experimental results to the geometrical scale of the bubble column (i.e., “large-diameter”, “small-diameter”, “coarse gas sparger”, fine gas sparger”, etc.); in particular, information on non-dimensional bubble column diameters, aspect ratios and gas sparger openings should be always provided
  • In comparisons involving the flow regime transition, detailed information concerning the flow regime transition criteria should be specified; in addition, authors should carefully evaluate if the flow regime transition method is suitable with the applied definition of flow regime transition;
  • When presenting a numerical approach, sensitivity studies on (a) interfacial closures; (b) time and (c) space discretization should be always be performed;
  • The modeling approach of the dispersed phase (i.e., mono-dispersed, bi-dispersed, PBM) should always be related to the prevailing flow regime observed in the bubble column;

5.3. Outlooks

Based on the literature survey proposed in this paper, some main comments concerning future studies are provided.
In particular, future experimental studies should be mainly devoted to the following:
  • Proposing a precise mathematical description of the flow regime transitions, as listed and described in Section 2.2.2. This approach should take into account the role of instabilities in flow regime transitions, to support the mathematical description of the boundaries of the flow regimes; in particular, this approach should be applied to develop a comprehensive flow regime map;
  • Performing comprehensive and multi-scale experimental studies to propose complete datasets for large-scale bubble columns (viz. gas holdup, bubble size distributions and shape data, and local flow properties); such datasets would provide a valuable basis to validate numerical approaches for scaling-up purposes;
  • Understanding the influence of interfacial properties on the “bubble-scale” and clarifying how the “bubble-scale” influences the “reactor-scale”;
  • Proposing a unified theory to explain all the dual effects observed in the literature (e.g., viscous liquid phases, organic compounds, inorganic compounds, etc.);
  • Performing experimental studies concerning the influences of the operating conditions and phase properties on bubble shape in dense bubbly flow conditions; in this regard, approaches for studying the three-dimensional bubble shape should be developed;
  • Performing a comprehensive comparison of the experimental techniques for both the global and the local fluid dynamic properties;
Conversely, future numerical studies should be mainly devoted to the following:
  • Extending the validation of the “baseline” approaches, to establish a common numerical framework for both small scale and large scale bubble columns; the validation should consider both the local and the global fluid dynamics properties in bubble columns;
  • Extending the validation of numerical approaches to model the mass transfer phenomena in bubble columns;
  • Extending the validation of the numerical approaches to the heterogeneous flow regime.

Author Contributions

Giorgio Besagni conducted the literature survey, post-processed the literature data and wrote the paper. Fabio Inzoli and Thomas Ziegenhein revised the paper.

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

Non-Dimensional Numbers
A R = H 0 d c Aspect ratio
E o = g ( ρ L ρ G ) d e q 2 σ Eötvös number
M o = g ( ρ L ρ G ) μ L 4 ρ L 2 σ 3 Morton number
R e = ρ L U d e q μ L Reynolds number
W e = R e 2 ( M o E o ) 0.5 Weber number
c r k 2 / σ Frothing parameters
Acronyms
ARAspect Ratio
BSDBubble Size Distribution
CMCCarboxymethyl cellulose
DNSDirect numerical simulations
EtOHEthanol
HZDRHelmholtz–Zentrum Dresden–Rossendorf
MEGMonoethylene glycol
NaClSodium chloride
PBEPopulation Balance Equation
PBMPopulation Balance Model
PoliMiPolitecnico di Milano
RANSReynolds-averaged Navier–Stokes
RSMReynolds Stress Models
Symbols
u ¯ Local velocity[m/s]
aMajor axis of the bubble[m]
aiInterfacial area[1/mm]
BRetarded Hamaker constant[J m]
cMolar concentration[mol/L]
CParameter in Equation (31)[-]
c*Equilibrium concentration[mol/L]
cEtOH,wtMass concentration of EtOH[%]
cMEG,wtMass concentration of MEG[%]
ctMolar transition concentration of NaCl[mol/L]
cwtMass concentration[kg/L]
D*HNon-dimensional diameter (Equation (1))[-]
D*H,CrCritical non-dimensional diameter[-]
dbmaxMaximum stable bubble size[mm]
dcDiameter of the bubble column[m]
deqBubble equivalent diameter[mm]
DHHydraulic diameter[m]
doGas sparger holes diameter[mm]
eParameter in Equation (7)[-]
EBubble aspect ratio[-]
fFunction[-]
FDDrag force[kg/m2 s2]
FLLift force[kg/m2 s2]
FTDTurbulent dispersion force[kg/m2 s2]
FVMVirtual mass force[kg/m2 s2]
FWLWall force[kg/m2 s2]
gAcceleration due to gravity[m/s2]
hHeight along the bubble column[m]
H0Height of the free surface before aeration[m]
HcHeight of the bubble column[m]
HDHeight of the free surface after aeration[m]
KConsistency index[Pa s]
ki (i = 1, 2)Coefficients in the aspect ratio correlation (Equation (44))[-]
kLVolumetric mass transfer coefficient[m/s]
MIMomentum exchanges[kg/m2 s2]
n*Dimensionless concentration (Equation (2))[-]
PProbability density function in Equation (70)[-]
PvVapor pressure in Equation (9)[Pa]
rbBubble radius in Equation (2)[mm]
RbGas constant[J/mol K]
STotal source/sink term in the population balance equation[m3/s]
SbSource/sink term due to break-up[m3/s]
ScSource/sink term due to coalescence[m3/s]
SmSource/sink term due to mass transfer[m3/s]
SpSource/sink term due to pressure change[m3/s]
SphSource/sink term due to phase change[m3/s]
SrSource/sink term due to reaction[m3/s]
tTime[s]
TTemperature[K]
tGMean residence time of the dispersed phase[s]
uMean rise velocity[m/s]
USuperficial velocity[m/s]
U*Dimensionaless gas velocity[-]
ubLocal velocity of bubble volumes[m/s]
ubrBubble rising velocity in Equation (26)[m/s]
VVolume[m3]
VbBubble volume in population balance equations[m3]
zi (i = 1, …, 5)Coefficients in the aspect ratio correlation (Equation (44))[-]
Greek Symbols
α Void fraction in the Eulerian–Eulerian constitutive equations[-]
γ ˙ Shear rate[1/s]
τ ¯ Viscous and Reynolds stresses[kg/m s2]
βCoefficient in Equations (6) and (7)[-]
γCoefficient in Equation (6)[-]
ΓCoalescence rate[m3/s]
εHold-up[-]
εParameter in Equation (12)[-]
μDynamic viscosity[kg/m s]
μaApparent dynamic viscosity[kg/m s]
μeffEffective viscosity[kg/m s]
νBubble terminal velocity[m/s]
νLBubble terminal velocity[m2/s]
ρDensity[kg/m3]
σSurface tension[N/m]
τTime scale[1/s]
χKinematic surface tension[m3/s]
ΩBreak-up rate[m3/s]
Subscripts
cParameter related to the bubble column
coalescence induced bubblesCoalescence induced bubbles
crCritical parameter
GGas phase
jj-th dispersed phase in governing equations
kk-th continuous phase in governing equations
LLiquid phase
LocalLocal parameter
non-coalescence induced bubblesNon-coalescence induced bubbles
swarmSwarm parameter
transTransition point (it refers at the homogeneous flow regime)
trans,IFirst transition point (end of the homogeneous flow regime, defined when considering both the first and the second regime transitions)
trans,IISecond transition point (end of the transition flow regime, defined when considering both the first and the second regime transitions)
wtMass concentration
zGeneric phase in governing equations
Vector quantity

References

  1. Leonard, C.; Ferrasse, J.H.; Boutin, O.; Lefevre, S.; Viand, A. Bubble column reactors for high pressures and high temperatures operation. Chem. Eng. Res. Des. 2015, 100, 391–421. [Google Scholar] [CrossRef]
  2. Rollbusch, P.; Bothe, M.; Becker, M.; Ludwig, M.; Grünewald, M.; Schlüter, M.; Franke, R. Bubble columns operated under industrially relevant conditions–Current understanding of design parameters. Chem. Eng. Sci. 2015, 126, 660–678. [Google Scholar] [CrossRef]
  3. Deckwer, W.D. Bubble Column Reactors; John Wiley & Sons Ltd.: Chichester, UK, 1992. [Google Scholar]
  4. Zehner, P.; Kraume, M. Bubble Columns. In Ullmann’s Encyclopedia of Industrial Chemistry; Wiley-VCH Verlag GmbH & Co. KGaA: Weinheim, Germany, 2005. [Google Scholar]
  5. Kikukawa, H. Physical and transport properties governing bubble column operations. Int. J. Multiph. Flow 2017, 93, 115–129. [Google Scholar] [CrossRef]
  6. Sasaki, S.; Hayashi, K.; Tomiyama, A. Effects of liquid height on gas holdup in air–water bubble column. Exp. Therm. Fluid Sci. 2016, 72, 67–74. [Google Scholar] [CrossRef]
  7. Besagni, G.; Inzoli, F.; De Guido, G.; Pellegrini, L.A. Experimental investigation on the influence of ethanol on bubble column hydrodynamics. Chem. Eng. Res. Des. 2016, 1112, 1–15. [Google Scholar] [CrossRef]
  8. Zahradník, J.; Fialová, M.; Ruzicka, M.; Drahoš, J.; Kastanek, F.; Thomas, N.H. Duality of the gas-liquid flow regimes in bubble column reactors. Chem. Eng. Sci. 1997, 52, 3811–3826. [Google Scholar] [CrossRef]
  9. Lucas, D.; Rzehak, R.; Krepper, E.; Ziegenhein, T.; Liao, Y.; Kriebitzsch, S.; Apanasevich, P. A strategy for the qualification of multi-fluid approacheds for nuclear reactor safety. Nucl. Eng. Des. 2015. [Google Scholar] [CrossRef]
  10. Ziegenhein, T.; Rzehak, R.; Lucas, D. Transient simulation for large scale flow in bubble columns. Chem. Eng. Sci. 2015, 122, 1–13. [Google Scholar] [CrossRef]
  11. Besagni, G.; Inzoli, F.; De Guido, G.; Pellegrini, L.A. The dual effect of viscosity on bubble column hydrodynamics. Chem. Eng. Sci. 2017, 158, 509–538. [Google Scholar] [CrossRef]
  12. Besagni, G.; Inzoli, F. The effect of liquid phase properties on bubble column fluid dynamics: Gas holdup, flow regime transition, bubble size distributions and shapes, interfacial areas and foaming phenomena. Chem. Eng. Sci. 2017, 170, 270–296. [Google Scholar] [CrossRef]
  13. Mudde, R.F.; Harteveld, W.K.; van den Akker, H.E.A. Uniform Flow in Bubble Columns. Ind. Eng. Chem. Res. 2009, 48, 148–158. [Google Scholar] [CrossRef]
  14. Besagni, G.; Gallazzini, L.; Inzoli, F. Effect of gas sparger design on bubble column hydrodynamics using pure and binary liquid phases. Chem. Eng. Sci. 2018, 176, 116–126. [Google Scholar] [CrossRef]
  15. Takagi, S.; Matsumoto, Y. Surfactant effects on bubble motion and bubbly flows. Annu. Rev. Fluid Mech. 2011, 43, 615–636. [Google Scholar] [CrossRef]
  16. Takagi, S.; Ogasawara, T.; Matsumoto, Y. The effects of surfactant on the multiscale structure of bubbly flows. Philos. Trans. R. Sci. A Math. Phys. Eng. Sci. 2008, 366, 2117–2129. [Google Scholar] [CrossRef] [PubMed]
  17. Beinhauer, R. Dynamic Measurement of the Relative Gas Contents in Bubble Columns by Means of X-ray Absorption; TU Berlin: Berlin, Germany, 1971. [Google Scholar]
  18. Schumpe, A.; Grund, G. The Gas Disengagement Technique for Studying Gas Holdup Structure in Bubble Columns. Can. J. Chem. Eng. 1986, 64, 891–896. [Google Scholar] [CrossRef]
  19. Krishna, R.; Urseanu, M.I.; Dreher, A.J. Gas hold-up in bubble columns: Influence of alcohol addition versus operation at elevated pressures. Chem. Eng. Process. Process Intensif. 2000, 39, 371–378. [Google Scholar] [CrossRef]
  20. Krishna, R.; Dreher, A.J.; Urseanu, M.I. Influence of alcohol addition on gas hold-up in bubble columns: Development of a scale up model. Int. Commun. Heat Mass Transf. 2000, 27, 465–472. [Google Scholar] [CrossRef]
  21. Montoya, G.; Lucas, D.; Baglietto, E.; Liao, Y. A review on mechanisms and models for the churn-turbulent flow regime. Chem. Eng. Sci. 2016, 141, 86–103. [Google Scholar] [CrossRef]
  22. Kitscha, J.; Kocamustafaogullari, G. Breakup criteria for fluid particles. Int. J. Multiph. Flow 1989, 15, 573–588. [Google Scholar] [CrossRef]
  23. Brooks, C.S.; Paranjape, S.S.; Ozar, B.; Hibiki, T.; Ishii, M. Two-group drift-flux model for closure of the modified two-fluid model. Int. J. Heat Fluid Flow 2012, 37, 196–208. [Google Scholar] [CrossRef]
  24. Shah, Y.T.; Kelkar, B.G.; Godbole, S.P.; Deckwer, W.D. Design parameters estimations for bubble column reactors. AIChE J. 1982, 28, 353–379. [Google Scholar] [CrossRef]
  25. Deckwer, W.-D.; Field, R.W. Bubble Column Reactors; Wiley: New York, NY, USA, 1992; Volume 200. [Google Scholar]
  26. Nedeltchev, S.; Shaikh, A. A new method for identification of the main transition velocities in multiphase reactors based on information entropy theory. Chem. Eng. Sci. 2013, 100, 2–14. [Google Scholar] [CrossRef]
  27. Nedeltchev, S. New methods for flow regime identification in bubble columns and fluidized beds. Chem. Eng. Sci. 2015, 137, 436–446. [Google Scholar] [CrossRef]
  28. Besagni, G.; Di Pasquali, A.; Gallazzini, L.; Gottardi, E.; Colombo, L.P.M.; Inzoli, F. The effect of aspect ratio in counter-current gas-liquid bubble columns: Experimental results and gas holdup correlations. Int. J. Multiph. Flow 2017, 94, 53–78. [Google Scholar] [CrossRef]
  29. Sarrafi, A.; Müller-Steinhagen, H.; Smith, J.M.; Jamialahmadi, M. Gas holdup in homogeneous and heterogeneous gas—liquid bubble column reactors. Can. J. Chem. Eng. 1999, 77, 11–21. [Google Scholar] [CrossRef]
  30. Ohki, Y.; Inoue, H. Longitudinal mixing of the liquid phase in bubble columns. Chem. Eng. Sci. 1970, 25, 1–16. [Google Scholar] [CrossRef]
  31. Ruzicka, M.C.; Drahoš, J.; Fialova, M.; Thomas, N.H. Effect of bubble column dimensions on flow regime transition. Chem. Eng. Sci. 2001, 56, 6117–6124. [Google Scholar] [CrossRef]
  32. Al-Oufi, F.M.; Rielly, C.D.; Cumming, I.W. An experimental study of gas void fraction in dilute alcohol solutions in annular gap bubble columns using a four-point conductivity probe. Chem. Eng. Sci. 2011, 66, 5739–5748. [Google Scholar] [CrossRef] [Green Version]
  33. Al-Oufi, F.M.; Cumming, I.W.; Rielly, C.D. Destabilisation of homogeneous bubbly flow in an annular gap bubble column. Can. J. Chem. Eng. 2010, 88, 482–490. [Google Scholar] [CrossRef] [Green Version]
  34. Besagni, G.; Inzoli, F. Influence of internals on counter-current bubble column hydrodynamics: Holdup, flow regime transition and local flow properties. Chem. Eng. Sci. 2016, 145, 162–180. [Google Scholar] [CrossRef] [Green Version]
  35. Xue, J.; Al-Dahhan, M.; Dudukovic, M.P.; Mudde, R.F. Bubble velocity, size, and interfacial area measurements in a bubble column by four-point optical probe. AIChE J. 2008, 54, 350–363. [Google Scholar] [CrossRef]
  36. Mohagheghian, S.; Elbing, B.R. Characterization of Bubble Size Distributions within a Bubble Column. Fluids 2018, 3, 13. [Google Scholar] [CrossRef]
  37. Besagni, G.; Gallazzini, L.; Inzoli, F. On the scale-up criteria for bubble columns. Petroleum 2017. [Google Scholar] [CrossRef]
  38. Passos, A.D.; Voulgaropoulos, V.P.; Paras, S.V.; Mouza, A.A. The effect of surfactant addition on the performance of a bubble column containing a non-Newtonian liquid. Chem. Eng. Res. Des. 2015, 95, 93–104. [Google Scholar] [CrossRef]
  39. Anastasiou, A.D.; Passos, A.D.; Mouza, A.A. Bubble columns with fine pore sparger and non-Newtonian liquid phase: Prediction of gas holdup. Chem. Eng. Sci. 2013, 98, 331–338. [Google Scholar] [CrossRef]
  40. Poulsen, B.R.; Iversen, J.J.L. Membrane sparger in bubble column, airlift, and combined membrane–ring sparger bioreactors. Biotechnol. Bioeng. 1999, 64, 452–458. [Google Scholar] [CrossRef]
  41. Garnier, C.; Lance, M.; Marié, J.L. Measurement of local flow characteristics in buoyancy-driven bubbly flow at high void fraction. Exp. Therm. Fluid Sci. 2002, 26, 811–815. [Google Scholar] [CrossRef]
  42. Ruzicka, M.C.; Zahradník, J.; Drahoš, J.; Thomas, N.H. Homogeneous–heterogeneous regime transition in bubble columns. Chem. Eng. Sci. 2001, 56, 4609–4626. [Google Scholar] [CrossRef]
  43. Zahradnik, J.; Kaštanek, F. Gas holdup in uniformly aerated bubble column reactors. Chem. Eng. Commun. 1979, 3, 413–429. [Google Scholar] [CrossRef]
  44. Thorat, B.N.; Joshi, J.B. Regime transition in bubble columns: Experimental and predictions. Exp. Therm. Fluid Sci. 2004, 28, 423–430. [Google Scholar] [CrossRef]
  45. Şal, S.; Gül, Ö.F.; Özdemir, M. The effect of sparger geometry on gas holdup and regime transition points in a bubble column equipped with perforated plate spargers. Chem. Eng. Process. Process Intensif. 2013, 70, 259–266. [Google Scholar] [CrossRef]
  46. Besagni, G.; Inzoli, F. Comprehensive experimental investigation of counter-current bubble column hydrodynamics: Holdup, flow regime transition, bubble size distributions and local flow properties. Chem. Eng. Sci. 2016, 146, 259–290. [Google Scholar] [CrossRef] [Green Version]
  47. Akita, K.; Yoshida, F. Gas Holdup and Volumetric Mass Transfer Coefficient in Bubble Columns. Effects of Liquid Properties. Ind. Eng. Chem. Process Des. Dev. 1973, 12, 76–80. [Google Scholar] [CrossRef]
  48. Jin, H.; Yang, S.; He, G.; Wang, M.; Williams, R.A. The effect of gas-liquid counter-current operation on gas hold-up in bubble columns using electrical resistance tomography. J. Chem. Technol. Biotechnol. 2010, 85, 1278–1283. [Google Scholar] [CrossRef]
  49. Otake, T.; Tone, S.; Shinohara, K. Gas holdup in the bubble column with cocurrent and countercurrent gas-liquid flow. J. Chem. Eng. Jpn. 1981, 338–340. [Google Scholar] [CrossRef]
  50. Yamaguchi, K.; Yamazaki, Y. Characteristics of Counter current Gas-Liquid Two-Phase Flow in Vertical Tubes. J. Nucl. Eng. Des. Sci. Technol. 1982, 19, 985–996. [Google Scholar] [CrossRef]
  51. Besagni, G.; Guédon, G.; Inzoli, F. Experimental investigation of counter current air-water flow in a large diameter vertical pipe with inners. J. Phys. Conf. Ser. 2014, 547, 012024. [Google Scholar] [CrossRef]
  52. Besagni, G.; Guédon, G.R.; Inzoli, F. Annular Gap Bubble Column: Experimental Investigation and Computational Fluid Dynamics Modeling. J. Fluids Eng. 2016, 138, 011302. [Google Scholar] [CrossRef] [Green Version]
  53. Besagni, G.; Inzoli, F. Bubble size distributions and shapes in annular gap bubble column. Exp. Therm. Fluid Sci. 2016, 4, 27–48. [Google Scholar] [CrossRef] [Green Version]
  54. De Guido, G.; Besagni, G.; Inzoli, F.; Pellegrini, L.A. New gas holdup data in large counter-current bubble columns. In Proceedings of the ICMF-2016–9th International Conference on Multiphase Flow, Florence, Italy, 22–27 May 2016. [Google Scholar]
  55. Trivedi, R.; Renganathan, T.; Krishnaiah, K. Hydrodynamics of countercurrent bubble column: Experiments and predictions. Chem. Eng. J. 2018, 338, 636–650. [Google Scholar] [CrossRef]
  56. Wilkinson, P.M.; Spek, A.P.; van Dierendonck, L.L. Design Parameters Estimation for Scale-Up of High-Pressure Bubble Columns. AIChE J. 1992, 38, 544–554. [Google Scholar] [CrossRef]
  57. Yang, J.H.; Yang, J.-I.; Kim, H.-J.; Chun, D.H.; Lee, H.-T.; Jung, H. Two regime transitions to pseudo-homogeneous and heterogeneous bubble flow for various liquid viscosities. Chem. Eng. Process. Process Intensif. 2010, 49, 1044–1050. [Google Scholar] [CrossRef]
  58. Lange, V.; Azzopardi, B.J.; Licence, P. Hydrodynamics of ionic liquids in bubble columns. In Ionic Liquids-New Aspects for the Future; InTechOpen: London, UK, 2013. [Google Scholar] [CrossRef]
  59. Kuncová, G.; Zahradník, J. Gas holdup and bubble frequency in a bubble column reactor containing viscous saccharose solutions. Chem. Eng. Process. Process Intensif. 1995, 34, 25–34. [Google Scholar] [CrossRef]
  60. Ruzicka, M.C.; Drahoš, J.; Mena, P.C.; Teixeira, J.A. Effect of viscosity on homogeneous–heterogeneous flow regime transition in bubble columns. Chem. Eng. J. 2003, 96, 15–22. [Google Scholar] [CrossRef] [Green Version]
  61. Olivieri, G.; Elena Russo, M.; Simeone, M.; Marzocchella, A.; Salatino, P. Effects of viscosity and relaxation time on the hydrodynamics of gas–liquid systems. Chem. Eng. Sci. 2011, 66, 3392–3399. [Google Scholar] [CrossRef]
  62. Rabha, S.; Schubert, M.; Hampel, U. Regime transition in viscous and pseudo viscous systems: A comparative study. AIChE J. 2014, 60, 3079–3090. [Google Scholar] [CrossRef]
  63. Marrucci, G.; Nicodemo, L. Coalescence of gas bubbles in aqueous solutions of inorganic electrolytes. Chem. Eng. Sci. 1967, 22, 1257–1265. [Google Scholar] [CrossRef]
  64. Keitel, G.; Onken, U. Inhibition of bubble coalescence by solutes in air/water dispersions. Chem. Eng. Sci. 1982, 37, 1635–1638. [Google Scholar] [CrossRef]
  65. Firouzi, M.; Howes, T.; Nguyen, A.V. A quantitative review of the transition salt concentration for inhibiting bubble coalescence. Adv. Colloid Interface Sci. 2015, 222, 305–318. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  66. Craig, V.S.J.; Ninham, B.W.; Pashley, R.M. The effect of electrolytes on bubble coalescence in water. J. Phys. Chem. 1993, 97, 10192–10197. [Google Scholar] [CrossRef]
  67. Deschenes, L.A.; Barrett, J.; Muller, L.J.; Fourkas, J.T.; Mohanty, U. Inhibition of Bubble Coalescence in Aqueous Solutions. 1. Electrolytes. J. Phys. Chem. B 1998, 102, 5115–5119. [Google Scholar] [CrossRef]
  68. Weissenborn, P.K.; Pugh, R.J. Surface Tension of Aqueous Solutions of Electrolytes: Relationship with Ion Hydration, Oxygen Solubility, and Bubble Coalescence. J. Colloid Interface Sci. 1996, 184, 550–563. [Google Scholar] [CrossRef] [PubMed]
  69. Orvalho, S.; Ruzicka, M.C.; Drahos, J. Bubble Column with Electrolytes: Gas Holdup and Flow Regimes. Ind. Eng. Chem. Res. 2009, 48, 8237–8243. [Google Scholar] [CrossRef]
  70. Ruzicka, M.C.; Vecer, M.M.; Orvalho, S.; Drahoš, J. Effect of surfactant on homogeneous regime stability in bubble column. Chem. Eng. Sci. 2008, 63, 951–967. [Google Scholar] [CrossRef]
  71. Zahradník, J.; Fialová, M.; Linek, V. The effect of surface-active additives on bubble coalescence in aqueous media. Chem. Eng. Sci. 1999, 54, 4757–4766. [Google Scholar] [CrossRef]
  72. Prince, M.J.; Blanch, H.W. Transition electrolyte concentrations for bubble coalescence. AIChE J. 1990, 36, 1425–1429. [Google Scholar] [CrossRef]
  73. Lessard, R.R.; Zieminski, S.A. Bubble Coalescence and Gas Transfer in Aqueous Electrolytic Solutions. Ind. Eng. Chem. Fundam. 1971, 10, 260–269. [Google Scholar] [CrossRef]
  74. Nguyen, P.T.; Hampton, M.A.; Nguyen, A.V.; Birkett, G.R. The influence of gas velocity, salt type and concentration on transition concentration for bubble coalescence inhibition and gas holdup. Chem. Eng. Res. Des. 2012, 90, 33–39. [Google Scholar] [CrossRef]
  75. Besagni, G.; Inzoli, F. Influence of electrolyte concentration on holdup, flow regime transition and local flow properties in a large scale bubble column. J. Phys. Conf. Ser. 2015, 655, 012039. [Google Scholar] [CrossRef]
  76. Ribeiro, C.P., Jr.; Mewes, D. The influence of electrolytes on gas hold-up and regime transition in bubble columns. Chem. Eng. Sci. 2007, 62, 4501–4509. [Google Scholar] [CrossRef]
  77. Kelkar, B.G.; Phulgaonkar, S.R.; Shah, Y.T. The effect of electrolyte solutions on hydrodynamic and backmixing characteristics in bubble columnns. Chem. Eng. J. 1983, 27, 125–133. [Google Scholar] [CrossRef]
  78. Grover, G.S.; Rode, C.V.; Chaudhari, R.V. Effect of temperature on flow regimes and gas hold-up in a bubble column. Can. J. Chem. Eng. 1986, 64, 501–504. [Google Scholar] [CrossRef]
  79. Jamialahmadi, M.; Müller-Steinhagen, H. Effect of alcohol, organic acid and potassium chloride concentration on bubble size, bubble rise velocity and gas hold-up in bubble columns. Chem. Eng. J. 1992, 50, 47–56. [Google Scholar] [CrossRef]
  80. Hikita, H.; Asai, S.; Tanigawa, K.; Segawa, K.; Kitao, M. Gas hold-up in bubble columns. Chem. Eng. J. 1980, 20, 59–67. [Google Scholar] [CrossRef]
  81. Albijanić, B.; Havran, V.; Petrović, D.L.; Durić, M.; Tekić, M.N. Hydrodynamics and mass transfer in a draft tube airlift reactor with dilute alcohol solutions. AIChE J. 2007, 53, 2897–2904. [Google Scholar] [CrossRef]
  82. Krishna, R.; Ellenberger, J.; Maretto, C. Flow regime transition in bubble columns. Int. Commun. Heat Mass Transf. 1999, 26, 467–475. [Google Scholar] [CrossRef]
  83. Dargar, P.; Macchi, A. Effect of surface-active agents on the phase holdups of three-phase fluidized beds. Chem. Eng. Process. Process Intensif. 2006, 45, 764–772. [Google Scholar] [CrossRef]
  84. Clark, K.N. The effect of high pressure and temperature on phase distributions in a bubble column. Chem. Eng. Sci. 1990, 45, 2301–2307. [Google Scholar] [CrossRef]
  85. Cui, Z. Hydrodynamics in a Bubble Column at Elevated Pressures and Turbulence Energy Distribution in Bubbling Gas-Liquid and Gas-Liquid-Solid Flow Systems; The Ohio State University: Columbus, OH, USA, 2005. [Google Scholar]
  86. Hashemi, S.; Macchi, A.; Servio, P. Gas–liquid mass transfer in a slurry bubble column operated at gas hydrate forming conditions. Chem. Eng. Sci. 2009, 64, 3709–3716. [Google Scholar] [CrossRef]
  87. Kang, Y.; Cho, Y.J.; Woo, K.J.; Kim, K.I.; Kim, S.D. Bubble properties and pressure fluctuations in pressurized bubble columns. Chem. Eng. Sci. 2000, 55, 411–419. [Google Scholar] [CrossRef]
  88. Kemoun, A.; Cheng Ong, B.; Gupta, P.; Al-Dahhan, M.H.; Dudukovic, M.P. Gas holdup in bubble columns at elevated pressure via computed tomography. Int. J. Multiph. Flow 2001, 27, 929–946. [Google Scholar] [CrossRef]
  89. Krishna, R.; Wilkinson, P.M.; Van Dierendonck, L.L. A model for gas holdup in bubble columns incorporating the influence of gas density on flow regime transitions. Chem. Eng. Sci. 1991, 46, 2491–2496. [Google Scholar] [CrossRef]
  90. Kumar, S.; Munshi, P.; Khanna, A. High Pressure Experiments and Simulations in Cocurrent Bubble Columns. Procedia Eng. 2012, 42, 842–853. [Google Scholar] [CrossRef]
  91. Letzel, H.M.; Schouten, J.C.; van den Bleek, C.M.; Krishna, R. Influence of elevated pressure on the stability of bubbly flows. Chem. Eng. Sci. 1997, 52, 3733–3739. [Google Scholar] [CrossRef]
  92. Letzel, M.H.; Schouten, J.C.; van den Bleek, C.M.; Krishna, R. Effect of gas density on large-bubble holdup in bubble column reactors. AIChE J. 1998, 44, 2333–2336. [Google Scholar] [CrossRef]
  93. Lin, T.J.; Juang, R.C.; Chen, C.C. Characterizations of flow regime transitions in a high-pressure bubble column by chaotic time series analysis of pressure fluctuation signals. Chem. Eng. Sci. 2001, 56, 6241–6247. [Google Scholar] [CrossRef]
  94. Reilly, I.; Scott, D.; Debruijn, T.; MacIntyre, D. The role of gas phase momentum in determining gas holdup and hydrodynamic flow regimes in bubble column operations. Can. J. Chem. Eng. 1994, 72, 3–12. [Google Scholar] [CrossRef]
  95. Shaikh, A.; Al-Dahhan, M. Characterization of the hydrodynamic flow regime in bubble columns via computed tomography. Flow Meas. Instrum. 2005, 16, 91–98. [Google Scholar] [CrossRef]
  96. Han, L.; Al-Dahhan, M.H. Gas–liquid mass transfer in a high pressure bubble column reactor with different sparger designs. Chem. Eng. Sci. 2007, 62, 131–139. [Google Scholar] [CrossRef]
  97. Fan, L.S.; Yang, G.Q.; Lee, D.J.; Tsuchiya, K.; Luo, X. Some aspects of high-pressure phenomena of bubbles in liquids and liquid–solid suspensions. Chem. Eng. Sci. 1999, 54, 4681–4709. [Google Scholar] [CrossRef]
  98. Wilkinson, P.M.; Dierendonck, L.L.V. Pressure and gas density effects on bubble break-up and gas hold-up in bubble columns. Chem. Eng. Sci. 1990, 45, 2309–2315. [Google Scholar] [CrossRef]
  99. Lott, F.; Kelder, H.; Teitelbaum, H. A transition from Kelvin–Helmholtz instabilities to propagating wave instabilities. Phys. Fluids A Fluid Dyn. 1992, 4, 1990–1997. [Google Scholar] [CrossRef]
  100. Bukur, D.B.; Petrovic, D.; Daly, J.G. Flow regime transitions in a bubble column with a paraffin wax as the liquid medium. Ind. Eng. Chem. Res. 1987, 26, 1087–1092. [Google Scholar] [CrossRef]
  101. Lin, T.J.; Tsuchiya, K.; Fan, L.-S. On the measurements of regime transition in high-pressure bubble columns. Can. J. Chem. Eng. 1999, 77, 370–374. [Google Scholar] [CrossRef]
  102. Shaikh, A.; Al-Dahhan Muthanna, H. A Review on Flow Regime Transition in Bubble Columns. Int. J. Chem. React. Eng. 2007, 5. [Google Scholar] [CrossRef]
  103. Zhang, J.P.; Grace, J.R.; Epstein, N.; Lim, K.S. Flow regime identification in gas-liquid flow and three-phase fluidized beds. Chem. Eng. Sci. 1997, 52, 3979–3992. [Google Scholar] [CrossRef]
  104. Wu, B.; Firouzi, M.; Mitchell, T.; Rufford, T.E.; Leonardi, C.; Towler, B. A critical review of flow maps for gas-liquid flows in vertical pipes and annuli. Chem. Eng. J. 2017, 326, 350–377. [Google Scholar] [CrossRef]
  105. Fair, J.R.; Lambright, A.J.; Andersen, J.W. Heat Transfer and Gas Holdup in a Sparged Contactor. Ind. Eng. Chem. Process Des. Dev. 1962, 1, 33–36. [Google Scholar] [CrossRef]
  106. Gopal, J.S.; Sharma, M.M. Mass transfer characteristics of low H/D bubble columns. Can. J. Chem. Eng. 1983, 61, 517–526. [Google Scholar] [CrossRef]
  107. Sada, E.; Katoh, S.; Yoshii, H.; Yamanishi, T.; Nakanishi, A. Performance of the gas bubble column in molten salt systems. Ind. Eng. Chem. Process Des. Dev. 1984, 23, 151–154. [Google Scholar] [CrossRef]
  108. Reilly, I.G.; Scott, D.S.; De Bruijn, T.; Jain, A.; Piskorz, J. A correlation for gas holdup in turbulent coalescing bubble columns. Can. J. Chem. Eng. 1986, 64, 705–717. [Google Scholar] [CrossRef]
  109. Kawase, Y.; Moo-Young, M. Influence of antifoam agents on gas hold-up and mass transfer in bubble columns with non-newtonian fluids. Appl. Microbiol. Biotechnol. 1987, 27, 159–167. [Google Scholar] [CrossRef]
  110. Ying, D.H.; Moujaes, S.; Sivasubramanian, R.; Givens, E. Gas/Slurry Flow in Coal-Liquefaction Processes (Fluid Dynamics in 3-Phase-Flow Column); Quarterly Technical Progress Report, 1 January–31 March 1981; Air Products and Chemicals, Inc.: Allentown, PA, USA, 1981. [Google Scholar]
  111. Thorat, B.N.; Shevade, A.V.; Bhilegaonkar, K.N.; Aglawe, R.H.; Parasu Veera, U.; Thakre, S.S.; Pandit, A.B.; Sawant, S.B.; Joshi, J.B. Effect of Sparger Design and Height to Diameter Ratio on Fractional Gas Hold-up in Bubble Columns. Chem. Eng. Res. Des. 1998, 76, 823–834. [Google Scholar] [CrossRef]
  112. Yoshida, F.; Akita, K. Performance of gas bubble columns: Volumetric liquid-phase mass transfer coefficient and gas holdup. AIChE J. 1965, 11, 9–13. [Google Scholar] [CrossRef]
  113. Voigt, J.; Schügerl, K. Absorption of oxygen in countercurrent multistage bubble columns—I Aqueous solutions with low viscosity. Chem. Eng. Sci. 1979, 34, 1221–1229. [Google Scholar] [CrossRef]
  114. Rollbusch, P.; Becker, M.; Ludwig, M.; Bieberle, A.; Grünewald, M.; Hampel, U.; Franke, R. Experimental investigation of the influence of column scale, gas density and liquid properties on gas holdup in bubble columns. Int. J. Multiph. Flow 2015, 75, 88–106. [Google Scholar] [CrossRef]
  115. Sangnimnuan, A.; Prasad, G.N.; Agnew, J.B. Gas hold-up and backmixing in a bubble-column reactor under coal-hydroliquefaction conditions. Chem. Eng. Commun. 1984, 25, 193–212. [Google Scholar] [CrossRef]
  116. de Bruijn, T.J.W.; Chase, J.D.; Dawson, W.H. Gas holdup in a two-phase vertical tubular reactor at high pressure. Can. J. Chem. Eng. 1988, 66, 330–333. [Google Scholar] [CrossRef]
  117. Lau, R.; Peng, W.; Velazquez-Vargas, L.G.; Yang, G.Q.; Fan, L.S. Gas-Liquid Mass Transfer in High-Pressure Bubble Columns. Ind. Eng. Chem. Res. 2004, 43, 1302–1311. [Google Scholar] [CrossRef]
  118. Yang, G.Q.; Fan, L.S. Axial liquid mixing in high-pressure bubble columns. AIChE J. 2003, 49, 1995–2008. [Google Scholar] [CrossRef]
  119. Shawaqfeh, A.T. Gas holdup and liquid axial dispersion under slug flow conditions in gas–liquid bubble column. Chem. Eng. Process. Process Intensif. 2003, 42, 767–775. [Google Scholar] [CrossRef]
  120. Hills, J.H. The operation of a bubble column at high throughputs: I. Gas holdup measurements. Chem. Eng. J. 1976, 12, 89–99. [Google Scholar] [CrossRef]
  121. Baawain, M.S.; El-Din, M.G.; Smith, D.W. Artificial neural networks modeling of ozone bubble columns: Mass transfer coefficient, gas hold-up, and bubble size. Ozone Sci. Eng. 2007, 29, 343–352. [Google Scholar] [CrossRef]
  122. Chaumat, H.; Billet-Duquenne, A.M.; Augier, F.; Mathieu, C.; Delmas, H. Mass transfer in bubble column for industrial conditions—Effects of organic medium, gas and liquid flow rates and column design. Chem. Eng. Sci. 2005, 60, 5930–5936. [Google Scholar] [CrossRef] [Green Version]
  123. Jin, H.; Yang, S.; Wang, M.; Williams, R.A. Measurement of gas holdup profiles in a gas liquid cocurrent bubble column using electrical resistance tomography. Flow Meas. Instrum. 2007, 18, 191–196. [Google Scholar] [CrossRef]
  124. Kumar, S.; Kumar, R.A.; Munshi, P.; Khanna, A. Gas Hold-up in Three Phase Co-current Bubble Columns. Procedia Eng. 2012, 42, 782–794. [Google Scholar] [CrossRef]
  125. Pjontek, D.; Parisien, V.; Macchi, A. Bubble characteristics measured using a monofibre optical probe in a bubble column and freeboard region under high gas holdup conditions. Chem. Eng. Sci. 2014, 111, 153–169. [Google Scholar] [CrossRef]
  126. Shah, M.; Kiss, A.A.; Zondervan, E.; Van Der Schaaf, J.; De Haan, A.B. Gas holdup, axial dispersion, and mass transfer studies in bubble columns. Ind. Eng. Chem. Res. 2012, 51, 14268–14278. [Google Scholar] [CrossRef]
  127. Simonnet, M.; Gentric, C.; Olmos, E.; Midoux, N. Experimental determination of the drag coefficient in a swarm of bubbles. Chem. Eng. Sci. 2007, 62, 858–866. [Google Scholar] [CrossRef]
  128. Biń, A.K.; Duczmal, B.; Machniewski, P. Hydrodynamics and ozone mass transfer in a tall bubble column. Chem. Eng. Sci. 2001, 56, 6233–6240. [Google Scholar] [CrossRef]
  129. Krishna, R.; Ellenberger, J. Gas holdup in bubble column reactors operating in the churn-turbulent flow regime. AIChE J. 1996, 42, 2627–2634. [Google Scholar] [CrossRef]
  130. Krishna, R.; Baten, J.M.v.; Urseanu, M.I. Scale Effects on the Hydrodynamics of Bubble Columns Operating in the Homogeneous Flow Regime. Chem. Eng. Technol. 2001, 24, 451–458. [Google Scholar] [CrossRef]
  131. Urseanu, M.I.; Guit, R.P.M.; Stankiewicz, A.; van Kranenburg, G.; Lommen, J.H.G.M. Influence of operating pressure on the gas hold-up in bubble columns for high viscous media. Chem. Eng. Sci. 2003, 58, 697–704. [Google Scholar] [CrossRef]
  132. Behkish, A.; Lemoine, R.; Sehabiague, L.; Oukaci, R.; Morsi, B.I. Gas holdup and bubble size behavior in a large-scale slurry bubble column reactor operating with an organic liquid under elevated pressures and temperatures. Chem. Eng. J. 2007, 128, 69–84. [Google Scholar] [CrossRef]
  133. Hughmark, G.A. Holdup and Mass Transfer in Bubble Columns. Ind. Eng. Chem. Process Des. Dev. 1967, 6, 218–220. [Google Scholar] [CrossRef]
  134. Kato, Y.; Nishiwaki, A.; Fukuda, T.; Tanaka, S. The behavior of suspended solid particles and liquid in bubble columns. J. Chem. Eng. Jpn. 1972, 5, 112–118. [Google Scholar] [CrossRef]
  135. Koide, K.; Morooka, S.; Ueyama, K.; Matsuura, A.; Yamashita, F.; Iwamoto, S.; Kato, Y.; Inoue, H.; Shigeta, M.; Suzuki, S.; et al. Behavior of bubbles in large scale bubble column. J. Chem. Eng. Jpn. 1979, 12, 98–104. [Google Scholar] [CrossRef]
  136. Deckwer, W.-D.; Louisi, Y.; Zaidi, A.; Ralek, M. Hydrodynamic Properties of the Fischer-Tropsch Slurry Process. Ind. Eng. Chem. Process Des. Dev. 1980, 19, 699–708. [Google Scholar] [CrossRef]
  137. Nottenkamper, R.; Steiff, A.; Weinspach, P. Experimental investigation of hydrodynamics of bubble columns. Ger. Chem. Eng. 1983, 6, 147–155. [Google Scholar]
  138. Koide, K.; Takazawa, A.; Komura, M.; Matsunaga, H. Gas holdup and volumetric liquid-phase mass transfer coefficient in solid-suspended bubble columns. J. Chem. Eng. Jpn. 1984, 17, 459–466. [Google Scholar] [CrossRef]
  139. Lemoine, R.; Behkish, A.; Sehabiague, L.; Heintz, Y.J.; Oukaci, R.; Morsi, B.I. An algorithm for predicting the hydrodynamic and mass transfer parameters in bubble column and slurry bubble column reactors. Fuel Process. Technol. 2008, 89, 322–343. [Google Scholar] [CrossRef]
  140. Kantarci, N.; Borak, F.; Ulgen, K.O. Bubble column reactors. Process Biochem. 2005, 40, 2263–2283. [Google Scholar] [CrossRef]
  141. Forret, A.; Schweitzer, J.M.; Gauthier, T.; Krishna, R.; Schweich, D. Influence of scale on the hydrodynamics of bubble column reactors: An experimental study in columns of 0.1, 0.4 and 1 m diameters. Chem. Eng. Sci. 2003, 58, 719–724. [Google Scholar] [CrossRef]
  142. Patil, V.K.; Joshi, J.B.; Sharma, M.M. Sectionalised bubble column: Gas hold-up and wall side solid—Liquid mass transfer coefficient. Can. J. Chem. Eng. 1984, 62, 228–232. [Google Scholar] [CrossRef]
  143. Kastanek, F.; Zahradnik, J.; Kratochvil, J.; Cermak, J. Modeling of large-scale bubble column reactors for non-ideal gas–liquid systems. Front. Chem. React. Eng. 1984, 1, 330–344. [Google Scholar]
  144. Sasaki, S.; Uchida, K.; Hayashi, K.; Tomiyama, A. Effects of column diameter and liquid height on gas holdup in air-water bubble columns. Exp. Therm. Fluid Sci. 2017, 82, 359–366. [Google Scholar] [CrossRef]
  145. Besagni, G.; Guédon, G.R.; Inzoli, F. Computational fluid-dynamic modeling of the mono-dispersed homogeneous flow regime in bubble columns. Nuclear Eng. Des. 2018, 331, 222–237. [Google Scholar] [CrossRef]
  146. Reith, T.; Renken, S.; Israël, B.A. Gas hold-up and axial mixing in the fluid phase of bubble columns. Chem. Eng. Sci. 1968, 23, 619–629. [Google Scholar] [CrossRef]
  147. Krishna, R.; Sie, S.T. Design and scale-up of the Fischer–Tropsch bubble column slurry reactor. Fuel Process. Technol. 2000, 64, 73–105. [Google Scholar] [CrossRef]
  148. Bouaifi, M.; Hebrard, G.; Bastoul, D.; Roustan, M. A comparative study of gas hold-up, bubble size, interfacial area and mass transfer coefficients in stirred gas–liquid reactors and bubble columns. Chem. Eng. Process. Process Intensif. 2001, 40, 97–111. [Google Scholar] [CrossRef]
  149. Parasu Veera, U.; Joshi, J.B. Measurement of Gas Hold-up Profiles in Bubble Column by Gamma Ray Tomography: Effect of Liquid Phase Properties. Chem. Eng. Res. Des. 2000, 78, 425–434. [Google Scholar] [CrossRef]
  150. Eissa, S.H.; Schügerl, K. Holdup and backmixing investigations in cocurrent and countercurrent bubble columns. Chem. Eng. Sci. 1975, 30, 1251–1256. [Google Scholar] [CrossRef]
  151. Khare, A.S.; Joshi, J.B. Effect of fine particles on gas hold-up in three-phase sparged reactors. Chem. Eng. J. 1990, 44, 11–25. [Google Scholar] [CrossRef]
  152. Godbole, S.P.; Honath, M.F.; Shah, Y.T. Holdup structure in highly viscous Newtonian and non-Newtonian liquids in bubble columns. Chem. Eng. Commun. 1982, 16, 119–134. [Google Scholar] [CrossRef]
  153. Bach, H.F.; Pilhofer, T. Variation of Gas Holdup in Bubble Columns With Physical Properties of Liquids and Operating Parameters of Columns. Ger. Chem. Eng. 1978, 1, 270–275. [Google Scholar]
  154. Hwang, S.-J.; Cheng, Y.-L. Gas holdup and liquid velocity in three-phase internal-loop airlift reactors. Chem. Eng. Sci. 1997, 52, 3949–3960. [Google Scholar] [CrossRef]
  155. Ruthiya Keshav, C.; van der Schaaf, J.; Kuster Ben, F.M.; Schouten Jaap, C. Influence of Particles and Electrolyte on Gas Hold-Up and Mass Transfer in a Slurry Bubble Column. Int. J. Chem. React. Eng. 2006, 4. [Google Scholar] [CrossRef]
  156. Kluytmans, J.H.J.; Kuster, B.F.M.; Schouten, J.C. Gas Holdup in a Slurry Bubble Column:  Influence of Electrolyte and Carbon Particles. Ind. Eng. Chem. Res. 2001, 40, 5326–5333. [Google Scholar] [CrossRef]
  157. Kellermann, H.; Jüttner, K.; Kreysa, G. Dynamic modelling of gas hold-up in different electrolyte systems. J. Appl. Electrochem. 1998, 28, 311–319. [Google Scholar] [CrossRef]
  158. Zahradnik, J.; Fialova, M.; Kastanek, F.; Green, K.; Thomas, N. The effect of electrolytes on bubble coalescence and gas holdup in bubble column reactors. Chem. Eng. Res. Des. 1995, 73, 341–346. [Google Scholar]
  159. Zahradník, J.; Kuncová, G.; Fialová, M. The effect of surface active additives on bubble coalescence and gas holdup in viscous aerated batches. Chem. Eng. Sci. 1999, 54, 2401–2408. [Google Scholar] [CrossRef]
  160. Kelkar, B.G.; Godbole, S.P.; Honath, M.F.; Shah, Y.T.; Carr, N.L.; Deckwer, W.D. Effect of addition of alcohols on gas holdup and backmixing in bubble columns. AIChE J. 1983, 29, 361–369. [Google Scholar] [CrossRef]
  161. Shah, Y.T.; Joseph, S.; Smith, D.N.; Ruether, J.A. On the behavior of the gas phase in a bubble column with ethanol-water mixtures. Ind. Eng. Chem. Process Des. Dev. 1985, 24, 1140–1148. [Google Scholar] [CrossRef]
  162. Besagni, G.; Inzoli, F. The effect of electrolyte concentration on counter-current gas–liquid bubble column fluid dynamics: Gas holdup, flow regime transition and bubble size distributions. Chem. Eng. Res. Des. 2017, 118, 170–193. [Google Scholar] [CrossRef]
  163. Hur, Y.G.; Yang, J.H.; Jung, H.; Lee, K.Y. Continuous alcohol addition in vaporized form and its effect on bubble behavior in a bubble column. Chem. Eng. Res. Des. 2014, 92, 804–811. [Google Scholar] [CrossRef]
  164. Guo, K.; Wang, T.; Yang, G.; Wang, J. Distinctly different bubble behaviors in a bubble column with pure liquids and alcohol solutions. J. Chem. Technol. Biotechnol. 2016. [Google Scholar] [CrossRef]
  165. Syeda, S.R.; Afacan, A.; Chuang, K.T. Prediction of gas hold-up in a bubble column filled with pure and binary liquids. Can. J. Chem. Eng. 2002, 80, 44–50. [Google Scholar] [CrossRef]
  166. Bhaga, D.; Pruden, B.B.; Weber, M.E. Gas holdup in a bubble column containing organic liquid mixtures. Can. J. Chem. Eng. 1971, 49, 417–420. [Google Scholar] [CrossRef]
  167. Andrew, S. Frothing in two-component liquid mixtures. In Proceedings of the International Symposium on Distillation, Brighton, UK, 8–10 September 1969; pp. 73–78. [Google Scholar]
  168. Hecht, K.; Bey, O.; Ettmüller, J.; Graefen, P.; Friehmelt, R.; Nilles, M. Effect of Gas Density on Gas Holdup in Bubble Columns. Chem. Ing. Tech. 2015, 87, 762–772. [Google Scholar] [CrossRef]
  169. Jordan, U.; Schumpe, A. The gas density effect on mass transfer in bubble columns with organic liquids. Chem. Eng. Sci. 2001, 56, 6267–6272. [Google Scholar] [CrossRef]
  170. Letzel, H.M.; Schouten, J.C.; Krishna, R.; van den Bleek, C.M. Gas holdup and mass transfer in bubble column reactors operated at elevated pressure. Chem. Eng. Sci. 1999, 54, 2237–2246. [Google Scholar] [CrossRef]
  171. Shulman, H.L.; Molstad, M.C. Gas-Bubble Columns for Gas-Liquid Contacting. Ind. Eng. Chem. 1950, 42, 1058–1070. [Google Scholar] [CrossRef]
  172. Koetsier, W.T.; Van Swaaij, W.P.M.; Van der Most, M. Maximum hold-up in bubble columns. J. Chem. Eng. Jpn. 1976, 9, 332–333. [Google Scholar] [CrossRef]
  173. öztürk, S.S.; Schumpe, A.; Deckwer, W.D. Organic liquids in a bubble column: Holdups and mass transfer coefficients. AIChE J. 1987, 33, 1473–1480. [Google Scholar] [CrossRef]
  174. Behkish, A.; Lemoine, R.; Oukaci, R.; Morsi, B.I. Novel correlations for gas holdup in large-scale slurry bubble column reactors operating under elevated pressures and temperatures. Chem. Eng. J. 2006, 115, 157–171. [Google Scholar] [CrossRef]
  175. Dewes, I.; Schumpe, A. Gas density effect on mass transfer in the slurry bubble column. Chem. Eng. Sci. 1997, 52, 4105–4109. [Google Scholar] [CrossRef]
  176. Idogawa, K.; Ikeda, K.; Fukuda, T.; Morooka, S. Behavior of bubbles of the air-water system in a column under high pressure. Int. Chem. Eng. 1986, 26, 468–474. [Google Scholar]
  177. Ishiyama, H.; Isokawa, Y.; Sawai, J.; Kojima, H. Hydrodynamics in a small size pressurized bubble column. Chem. Eng. Sci. 2001, 56, 6273–6278. [Google Scholar] [CrossRef]
  178. Jiang, P.; Lin, T.J.; Luo, X.; Fan, L.S. Flow visualization of high pressure (21 MPa) bubble column: Bubble characteristics. Chem. Eng. Res. Des. 1995, 73, 269–274. [Google Scholar]
  179. Kang, Y.; Cho, Y.J.; Woo, K.J.; Kim, S.D. Diagnosis of bubble distribution and mass transfer in pressurized bubble columns with viscous liquid medium. Chem. Eng. Sci. 1999, 54, 4887–4893. [Google Scholar] [CrossRef]
  180. Lin, T.J.; Tsuchiya, K.; Fan, L.S. Bubble Flow Characteristics in Bubble Columns at Elevated Pressure and Temperature. AIChE J. 1998, 44, 545–560. [Google Scholar] [CrossRef]
  181. Luo, X.; Lee, D.J.; Lau, R.; Yang, G.; Fan, L.-S. Maximum stable bubble size and gas holdup in high-pressure slurry bubble columns. AIChE J. 1999, 45, 665–680. [Google Scholar] [CrossRef]
  182. Maalej, S.; Benadda, B.; Otterbein, M. Interfacial area and volumetric mass transfer coefficient in a bubble reactor at elevated pressures. Chem. Eng. Sci. 2003, 58, 2365–2376. [Google Scholar] [CrossRef]
  183. Schäfer, R.; Merten, C.; Eigenberger, G. Bubble size distributions in a bubble column reactor under industrial conditions. Exp. Therm. Fluid Sci. 2002, 26, 595–604. [Google Scholar] [CrossRef]
  184. Therning, P.; Rasmuson, A. Liquid dispersion, gas holdup and frictional pressure drop in a packed bubble column at elevated pressures. Chem. Eng. J. 2001, 81, 331–335. [Google Scholar] [CrossRef]
  185. Oyevaar, M.; Bos, R.; Westerterp, K. Interfacial areas and gas hold-ups in gas—Liquid contactors at elevated pressures from 0.1 to 8.0 MPa. Chem. Eng. Sci. 1991, 46, 1217–1231. [Google Scholar] [CrossRef]
  186. Lorenz, O.; Schumpe, A.; Ekambara, K.; Joshi, J.B. Liquid phase axial mixing in bubble columns operated at high pressures. Chem. Eng. Sci. 2005, 60, 3573–3586. [Google Scholar] [CrossRef]
  187. Pohorecki, R.; Moniuk, W.; Zdrójkowski, A.; Bielski, P. Hydrodynamics of a pilot plant bubble column under elevated temperature and pressure. Chem. Eng. Sci. 2001, 56, 1167–1174. [Google Scholar] [CrossRef]
  188. Soong, Y.; Harke, F.W.; Gamwo, I.K.; Schehl, R.R.; Zarochak, M.F. Hydrodynamic study in a slurry-bubble-column reactor. Catal. Today 1997, 35, 427–434. [Google Scholar] [CrossRef]
  189. Kölbel, H.; Klötzer, D.; Hammer, H. Zur Reaktionstechnik von Blasensäulen-Reaktoren mit suspendiertem Katalysator bei erhöhtem Druck. Chem. Ing. Tech. 1971, 43, 103–111. [Google Scholar] [CrossRef]
  190. Yang, W.; Wang, J.; Jin, Y. Mass transfer characteristics of syngas components in slurry system at industrial conditions. Chem. Eng. Technol. 2001, 24, 651–657. [Google Scholar] [CrossRef]
  191. Lockett, M.; Kirkpatrick, R. Ideal bubbly flow and actual flow in bubble columns. Trans. Inst. Chem. Eng 1975, 53, 267–273. [Google Scholar]
  192. Mashelkar, R. Bubble columns. Br. Chem. Eng. 1970, 15, 1297. [Google Scholar]
  193. Kato, Y.; Nishiwaki, A. Longitudinal dispersion coefficient of a liquid in a bubble column. Int. Chem. Eng. 1972, 12, 182–187. [Google Scholar] [CrossRef]
  194. Hikita, H.; Kikukawa, H. Liquid-phase mixing in bubble columns: Effect of liquid properties. Chem. Eng. J. 1974, 8, 191–197. [Google Scholar] [CrossRef]
  195. Gestrich, W.; Rähse, W. Der relative Gasgehalt von Blasenschichten. Chem. Ing. Tech. 1975, 47, 8–13. [Google Scholar] [CrossRef]
  196. Kumar, A.; Degaleesan, T.E.; Laddha, G.S.; Hoelscher, H.E. Bubble swarm characteristics in bubble columns. Can. J. Chem. Eng. 1976, 54, 503–508. [Google Scholar] [CrossRef]
  197. Friedel, L.; Herbrechtsmeier, P.; Steiner, R. Mean gas holdup in downflow bubble columns. Ger. Chem. Eng. 1980, 3, 342. [Google Scholar]
  198. Elgozali, A.; Linek, V.; Fialová, M.; Wein, O.; Zahradník, J. Influence of viscosity and surface tension on performance of gas–liquid contactors with ejector type gas distributor. Chem. Eng. Sci. 2002, 57, 2987–2994. [Google Scholar] [CrossRef]
  199. Mersmann, A. Design and scale-up of bubble and spray columns. Ger. Chem. Eng. 1978, 1, 1–11. [Google Scholar]
  200. Santus, D.; Salvagno, N. Purificazione di Gas Naturale da Composti Acidi Mediante Assorbimento Fisico Downhole. Master’s Thesis, Politecnico di Milano, Milan, Italy, 2014. [Google Scholar]
  201. Riquarts, H.-P.; Pilhofer, T. Modell des heterogenen Strömungszustandes in Blasensäulen. Verfahrenstechnik 1978, 12, 77–80. [Google Scholar]
  202. Iordache, O.M.; Muntean, O.I. Stochastic approach to the hydrodynamics of gas-liquid dispersions. Ind. Eng. Chem. Fundam. 1981, 20, 204–207. [Google Scholar] [CrossRef]
  203. Schumpe, A.; Deckwer, W.D. Viscous media in tower bioreactors: Hydrodynamic characteristics and mass transfer properties. Bioprocess Eng. 1987, 2, 79–94. [Google Scholar] [CrossRef]
  204. Kawase, Y.; Moo-Young, M. Theoretical prediction of gas hold-up in bubble columns with Newtonian and non-Newtonian fluids. Ind. Eng. Chem. Res. 1987, 26, 933–937. [Google Scholar] [CrossRef]
  205. Schumpe, A.; Deckwer, W.D. Gas holdups, specific interfacial areas, and mass transfer coefficients of aerated carboxymethyl cellulose solutions in a bubble column. Ind. Eng. Chem. Process Des. Dev. 1982, 21, 706–711. [Google Scholar] [CrossRef]
  206. Viswanathan, K.; Rao, D.S. Inviscid liquid circulation in bubble columns. Chem. Eng. Commun. 1984, 25, 133–155. [Google Scholar] [CrossRef]
  207. Kawase, Y.; Moo-Young, M. Influence of non-Newtonian flow behaviour on mass transfer in bubble columns with and without draft tubes. Chem. Eng. Commun. 1986, 40, 67–83. [Google Scholar] [CrossRef]
  208. Kataoka, H.; Takeuchi, H.; Nakao, K.; Yagi, H.; Tadaki, T.; Otake, T.; Miyauchi, T.; Washimi, K.; Watanabe, K.; Yoshida, F. Mass transfer in a large bubble column. J. Chem. Eng. Jpn. 1979, 12, 105–110. [Google Scholar] [CrossRef]
  209. Zou, R.; Jiang, X.; Li, B.; Zu, Y.; Zhang, L. Studies on gas holdup in a bubble column operated at elevated temperatures. Ind. Eng. Chem. Res. 1988, 27, 1910–1916. [Google Scholar] [CrossRef]
  210. Kawase, Y.; Umeno, S.; Kumagai, T. The prediction of gas hold-up in bubble column reactors: Newtonian and non-newtonian fluids. Chem. Eng. J. 1992, 50, 1–7. [Google Scholar] [CrossRef]
  211. Besagni, G.; Inzoli, F. Novel gas holdup and regime transition correlation for two-phase bubble columns. J. Phys. Conf. Ser. 2017, 923, 012011. [Google Scholar] [CrossRef]
  212. Gaddis, E.S.; Vogelpohl, A. Bubble formation in quiescent liquids under constant flow conditions. Chem. Eng. Sci. 1986, 41, 97–105. [Google Scholar] [CrossRef]
  213. Risso, F. Agitation, Mixing, and Transfers Induced by Bubbles. Annu. Rev. Fluid Mech. 2018, 50, 25–48. [Google Scholar] [CrossRef]
  214. Liao, Y.; Lucas, D. A literature review of theoretical models for drop and bubble breakup in turbulent dispersions. Chem. Eng. Sci. 2009, 64, 3389–3406. [Google Scholar] [CrossRef]
  215. Liao, Y.; Lucas, D. A literature review on mechanisms and models for the coalescence process of fluid particles. Chem. Eng. Sci. 2010, 65, 2851–2864. [Google Scholar] [CrossRef]
  216. Haberman, W.L.; Morton, R.K.; Basin, D.W.T.M. An Experimental Investigation of the Drag and Shape of Air Bubbles Rising in Various Liquids; Haberman, W.L., Morton, R.K., Eds.; David W. Taylor Model Basin: Washington, DC, USA, 1953. [Google Scholar] [CrossRef]
  217. Clift, R.; Grace, J.R.; Weber, M.E. Bubbles, Drops, and Particles; Dover Publications, Inc.: Mineola, NY, USA, 1978. [Google Scholar]
  218. Chao, B.T. Motion of Spherical Gas Bubbles in a Viscous Liquid at Large Reynolds Numbers. Phys. Fluids 1962, 5, 69–79. [Google Scholar] [CrossRef]
  219. Celata, G.P.; Cumo, M.; D’Annibale, F.; Di Marco, P.; Tomiyama, A.; Zovini, C. Effect of gas injection mode and purity of liquid on bubble rising in two-component systems. Exp. Therm. Fluid Sci. 2006, 31, 37–53. [Google Scholar] [CrossRef]
  220. Celata, G.P.; Cumo, M.; D’Annibale, F.; Tomiyama, A. The wake effect on bubble rising velocity in one-component systems. Int. J. Multiph. Flow 2004, 30, 939–961. [Google Scholar] [CrossRef]
  221. Celata, G.P.; D’Annibale, F.; Di Marco, P.; Memoli, G.; Tomiyama, A. Measurements of rising velocity of a small bubble in a stagnant fluid in one- and two-component systems. Exp. Therm. Fluid Sci. 2007, 31, 609–623. [Google Scholar] [CrossRef]
  222. Okawa, T.; Tanaka, T.; Kataoka, I.; Mori, M. Temperature effect on single bubble rise characteristics in stagnant distilled water. Int. J. Heat Mass Transf. 2003, 46, 903–913. [Google Scholar] [CrossRef]
  223. Wellek, R.M.; Agrawal, A.K.; Skelland, A.H.P. Shape of liquid drops moving in liquid media. AIChE J. 1966, 12, 854–862. [Google Scholar] [CrossRef]
  224. Moore, D.W. The rise of a gas bubble in a viscous liquid. J. Fluid Mech. 1959, 6, 113–130. [Google Scholar] [CrossRef]
  225. Taylor, T.D.; Acrivos, A. On the deformation and drag of a falling viscous drop at low Reynolds number. J. Fluid Mech. 1964, 18, 466–476. [Google Scholar] [CrossRef]
  226. Tadaki, T.; Maeda, S. On the shape and velocity of single air bubbles rising in various liquids. Kagaku Kogaku 1961, 25, 254–264. [Google Scholar] [CrossRef]
  227. Bozzano, G.; Dente, M. Shape and terminal velocity of single bubble motion: A novel approach. Comput. Chem. Eng. 2001, 25, 571–576. [Google Scholar] [CrossRef]
  228. Aoyama, S.; Hayashi, K.; Hosokawa, S.; Tomiyama, A. Shapes of ellipsoidal bubbles in infinite stagnant liquids. Int. J. Multiph. Flow 2016, 79, 23–30. [Google Scholar] [CrossRef]
  229. Besagni, G.; Brazzale, P.; Fiocca, A.; Inzoli, F. Estimation of bubble size distributions and shapes in two-phase bubble column using image analysis and optical probes. Flow Meas. Instrum. 2016. [Google Scholar] [CrossRef]
  230. Besagni, G.; Inzoli, F.; Ziegenhein, T.; Hessenkemper, H.; Lucas, D. Bubble aspect ratio in dense bubbly flows: Experimental studies in low Morton-number systems. J. Phys. Conf. Ser. 2017, 923, 012014. [Google Scholar] [CrossRef]
  231. Ziegenhein, T.; Lucas, D. Observations on bubble shapes in bubble columns under different flow conditions. Exp. Therm. Fluid Sci. 2017, 85, 248–256. [Google Scholar] [CrossRef]
  232. Chilekar, V.P.; van der Schaaf, J.; Kuster, B.F.M.; Tinge, J.T.; Schouten, J.C. Influence of elevated pressure and particle lyophobicity on hydrodynamics and gas–liquid mass transfer in slurry bubble columns. AIChE J. 2010, 56, 584–596. [Google Scholar] [CrossRef]
  233. Ferreira, A.; Cardoso, P.; Teixeira, J.A.; Rocha, F. pH influence on oxygen mass transfer coefficient in a bubble column. Individual characterization of kL and a. Chem. Eng. Sci. 2013, 100, 145–152. [Google Scholar] [CrossRef] [Green Version]
  234. García-Abuín, A.; Gómez-Díaz, D.; Losada, M.; Navaza, J.M. Bubble column gas–liquid interfacial area in a polymer+surfactant+water system. Chem. Eng. Sci. 2012, 75, 334–341. [Google Scholar] [CrossRef]
  235. García-Abuín, A.; Gómez-Díaz, D.; Navaza, J.M.; Vidal-Tato, I. CO2 capture by aqueous solutions of glucosamine in a bubble column reactor. Chem. Eng. J. 2010, 162, 37–42. [Google Scholar] [CrossRef]
  236. Lau, R.; Lee, P.H.V.; Chen, T. Mass transfer studies in shallow bubble column reactors. Chem. Eng. Process. Process Intensif. 2012, 62, 18–25. [Google Scholar] [CrossRef]
  237. Majumder, S.K.; Kundu, G.; Mukherjee, D. Bubble size distribution and gas–liquid interfacial area in a modified downflow bubble column. Chem. Eng. J. 2006, 122, 1–10. [Google Scholar] [CrossRef]
  238. Muroyama, K.; Imai, K.; Oka, Y.; Hayashi, J.I. Mass transfer properties in a bubble column associated with micro-bubble dispersions. Chem. Eng. Sci. 2013, 100, 464–473. [Google Scholar] [CrossRef]
  239. Smith, J.S.; Burns, L.F.; Valsaraj, K.T.; Thibodeaux, L.J. Bubble Column Reactors for Wastewater Treatment. 2. The Effect of Sparger Design on Sublation Column Hydrodynamics in the Homogeneous Flow Regime. Ind. Eng. Chem. Res. 1996, 35, 1700–1710. [Google Scholar] [CrossRef]
  240. Pohorecki, R.; Moniuk, W.; Zdrójkowski, A. Hydrodynamics of a bubble column under elevated pressure. Chem. Eng. Sci. 1999, 54, 5187–5193. [Google Scholar] [CrossRef]
  241. Rubia, M.D.L.; García-Abuín, A.; Gómez-Díaz, D.; Navaza, J.M. Interfacial area and mass transfer in carbon dioxide absorption in TEA aqueous solutions in a bubble column reactor. Chem. Eng. Process. Process Intensif. 2010, 49, 852–858. [Google Scholar] [CrossRef]
  242. Lau, Y.M.; Sujatha, K.T.; Gaeini, M.; Deen, N.G.; Kuipers, J.A.M. Experimental study of the bubble size distribution in a pseudo-2D bubble column. Chem. Eng. Sci. 2013, 98, 203–211. [Google Scholar] [CrossRef]
  243. Hernandez-Aguilar, J.R.; Coleman, R.G.; Gomez, C.O.; Finch, J.A. A comparison between capillary and imaging techniques for sizing bubbles in flotation systems. Miner. Eng. 2004, 17, 53–61. [Google Scholar] [CrossRef]
  244. Wongsuchoto, P.; Charinpanitkul, T.; Pavasant, P. Bubble size distribution and gas–liquid mass transfer in airlift contactors. Chem. Eng. J. 2003, 92, 81–90. [Google Scholar] [CrossRef]
  245. Parthasarathy, R.; Ahmed, N. Bubble Size Distribution in a Gas Sparged Vessel Agitated by a Rushton Turbine. Ind. Eng. Chem. Res. 1994, 33, 703–711. [Google Scholar] [CrossRef]
  246. Lu, J.; Biswas, S.; Tryggvason, G. A DNS study of laminar bubbly flows in a vertical channel. Int. J. Multiph. Flow 2006, 32, 643–660. [Google Scholar] [CrossRef]
  247. Lu, J.; Tryggvason, G. Effect of bubble size in turbulent bubbly downflow in a vertical channel. Chem. Eng. Sci. 2007, 62, 3008–3018. [Google Scholar] [CrossRef]
  248. Lu, J.; Tryggvason, G. Dynamics of nearly spherical bubbles in a turbulent channel upflow. J. Fluid Mech. 2013, 732, 166–189. [Google Scholar] [CrossRef]
  249. Ziegenhein, T.; Lucas, D. On sampling bias in multiphase flows: Particle image velocimetry in bubbly flows. Flow Meas. Instrum. 2016, 48, 36–41. [Google Scholar] [CrossRef]
  250. Ziegenhein, T.; Zalucky, J.; Rzehak, R.; Lucas, D. On the hydrodynamics of airlift reactors, Part I: Experiments. Chem. Eng. Sci. 2016, 150, 54–65. [Google Scholar] [CrossRef]
  251. Ziegenhein, T.; Garcon, M.; Lucas, D. Particle tracking using micro bubbles in bubbly flows. Chem. Eng. Sci. 2016, 153, 155–164. [Google Scholar] [CrossRef]
  252. Kulkarni, A.A.; Joshi, J.B. Bubble Formation and Bubble Rise Velocity in Gas−Liquid Systems:  A Review. Ind. Eng. Chem. Res. 2005, 44, 5873–5931. [Google Scholar] [CrossRef]
  253. Camarasa, E.; Vial, C.; Poncin, S.; Wild, G.; Midoux, N.; Bouillard, J. Influence of coalescence behaviour of the liquid and of gas sparging on hydrodynamics and bubble characteristics in a bubble column. Chem. Eng. Process. Process Intensif. 1999, 38, 329–344. [Google Scholar] [CrossRef]
  254. Polli, M.; Stanislao, M.D.; Bagatin, R.; Bakr, E.A.; Masi, M. Bubble size distribution in the sparger region of bubble columns. Chem. Eng. Sci. 2002, 57, 197–205. [Google Scholar] [CrossRef]
  255. Miyahara, T.; Tanaka, A. Size of bubbles generated from porous plates. J. Chem. Eng. Jpn. 1997, 30, 353–355. [Google Scholar] [CrossRef]
  256. Koide, K.; Kato, S.; Tanaka, Y.; Kubota, H. Bubbles generated from porous plates. J. Chem. Eng. Jpn. 1968, 1, 51–56. [Google Scholar] [CrossRef]
  257. Hur, Y.G.; Yang, J.H.; Jung, H.; Park, S.B. Origin of regime transition to turbulent flow in bubble column: Orifice- and column-induced transitions. Int. J. Multiph. Flow 2013, 50, 89–97. [Google Scholar] [CrossRef]
  258. Kazakis, N.A.; Mouza, A.A.; Paras, S.V. Experimental study of bubble formation at metal porous spargers: Effect of liquid properties and sparger characteristics on the initial bubble size distribution. Chem. Eng. J. 2008, 137, 265–281. [Google Scholar] [CrossRef]
  259. Manoharan, S.; Jog, M.A.; Manglik, R.M. Effects of Liquid Viscosity on Bubble Growth From Submerged Orifice Plates. Am. Soc. Mech. Eng. 2017. [Google Scholar] [CrossRef]
  260. Zhang, C.; Fu, T.; Zhu, C.; Jiang, S.; Ma, Y.; Li, H.Z. Dynamics of bubble formation in highly viscous liquids in a flow-focusing device. Chem. Eng. Sci. 2017, 172, 278–285. [Google Scholar] [CrossRef]
  261. Abbassi, W.; Besbes, S.; El Hajem, M.; Ben Aissia, H.; Champagne, J.Y.; Jay, J. Influence of operating conditions and liquid phase viscosity with volume of fluid method on bubble formation process. Eur. J. Mech.-B/Fluids 2017, 65, 284–298. [Google Scholar] [CrossRef]
  262. Philip, J.; Proctor, J.M.; Niranjan, K.; Davidson, J.F. Gas hold-up and liquid circulation in internal loop reactors containing highly viscous newtonian and non-newtonian liquids. Chem. Eng. Sci. 1990, 45, 651–664. [Google Scholar] [CrossRef]
  263. Xu, X.; Zhang, J.; Liu, F.; Wang, X.; Wei, W.; Liu, Z. Rising behavior of single bubble in infinite stagnant non-Newtonian liquids. Int. J. Multiph. Flow 2017, 95, 84–90. [Google Scholar] [CrossRef]
  264. Laupsien, D.; Cockx, A.; Line, A. Bubble Plume Oscillations in Viscous Fluids. Chem. Eng. Technol. 2017, 40, 1484–1493. [Google Scholar] [CrossRef]
  265. Sahu, K.C. A review on rising bubble dynamics in viscosity-stratified fluids. Sādhanā 2017, 42, 575–583. [Google Scholar]
  266. Zenit, R.; Feng, J.J. Hydrodynamic Interactions Among Bubbles, Drops, and Particles in Non-Newtonian Liquids. Annu. Rev. Fluid Mech. 2018, 50, 505–534. [Google Scholar] [CrossRef]
  267. Orvalho, S.; Ruzicka, M.C.; Olivieri, G.; Marzocchella, A. Bubble coalescence: Effect of bubble approach velocity and liquid viscosity. Chem. Eng. Sci. 2015, 134, 205–216. [Google Scholar] [CrossRef]
  268. Sun, W.; Zhu, C.; Fu, T.; Yang, H.; Ma, Y.; Li, H. The minimum in-line coalescence height of bubbles in non-Newtonian fluid. Int. J. Multiph. Flow 2017, 92, 161–170. [Google Scholar] [CrossRef]
  269. Gumulya, M.; Joshi, J.B.; Utikar, R.P.; Evans, G.M.; Pareek, V. Bubbles in viscous liquids: Time dependent behaviour and wake characteristics. Chem. Eng. Sci. 2016, 144, 298–309. [Google Scholar] [CrossRef]
  270. Keitel, G.; Onken, U. The effect of solutes on bubble size in air-water dispersions. Chem. Eng. Commun. 1982, 17, 85–98. [Google Scholar] [CrossRef]
  271. Machon, V.; Pacek, A.W.; Nienow, A.W. Bubble Sizes in Electrolyte and Alcohol Solutions in a Turbulent Stirred Vessel. Chem. Eng. Res. Des. 1997, 75, 339–348. [Google Scholar] [CrossRef]
  272. Lin, T.-J.; Fan, L.-S. Heat transfer and bubble characteristics from a nozzle in high-pressure bubble columns. Chem. Eng. Sci. 1999, 54, 4853–4859. [Google Scholar] [CrossRef]
  273. Ishibashi, H.; Onozaki, M.; Kobayashi, M.; Hayashi, J.I.; Itoh, H.; Chiba, T. Gas holdup in slurry bubble column reactors of a 150 t/d coal liquefaction pilot plant process. Fuel 2001, 80, 655–664. [Google Scholar] [CrossRef]
  274. Kováts, P.; Thévenin, D.; Zähringer, K. Characterizing fluid dynamics in a bubble column aimed for the determination of reactive mass transfer. Heat Mass Transf. 2018, 54, 453–461. [Google Scholar] [CrossRef]
  275. Hills, J. Radial non-uniformity of velocity and voidage in a bubble column. Trans. Inst. Chem. Eng 1974, 52, 1–9. [Google Scholar]
  276. Joshi, J.B.; Parasu, V.U.; Prasad, C.V.; Phanikumar, D.V.; Thakre, S.S.; Thorat, B.N. Gas holdu-up structure in bubble column reactors. PINSA 1998, 64, 441–567. [Google Scholar]
  277. Tomiyama, A.; Tamai, H.; Zun, I.; Hosokawa, S. Transverse migration of single bubbles in simple shear flows. Chem. Eng. Sci. 2002, 57, 1849–1858. [Google Scholar] [CrossRef]
  278. Lucas, D.; Prasser, H.M.; Manera, A. Influence of the lift force on the stability of a bubble column. Chem. Eng. Sci. 2005, 60, 3609–3619. [Google Scholar] [CrossRef]
  279. Wu, Y.; Cheng Ong, B.; Al-Dahhan, M.H. Predictions of radial gas holdup profiles in bubble column reactors. Chem. Eng. Sci. 2001, 56, 1207–1210. [Google Scholar] [CrossRef]
  280. Nassos, G.P.; Bankoff, S.G. Slip velocity ratios in an air-water system under steady-state and transient conditions. Chem. Eng. Sci. 1967, 22, 661–668. [Google Scholar] [CrossRef]
  281. Ueyama, K.; Miyauchi, T. Properties of recirculating turbulent two phase flow in gas bubble columns. AIChE J. 1979, 25, 258–266. [Google Scholar] [CrossRef]
  282. Luo, H.; Svendsen, H.F. Turbulent circulation in bubble columns from eddy viscosity distributions of single-phase pipe flow. Can. J. Chem. Eng. 1991, 69, 1389–1394. [Google Scholar] [CrossRef]
  283. Van Dierendonck, L.; Fortuin, J.; Venderbos, D. The specific contact area in gas-liquid reactors. In Proceedings of the 4th European Symposium on Chemical Reactor Engineering, Brussels, Belgium, 9 September 1968; pp. 205–215. [Google Scholar]
  284. Gestrich, W.; Krauss, W. Die spezifische Phasengrenzfläche in Blasenschichten. Chem. Ing. Tech. 1975, 47, 360–367. [Google Scholar] [CrossRef]
  285. Akita, K.; Yoshida, F. Bubble Size, Interfacial Area, and Liquid-Phase Mass Transfer Coefficient in Bubble Columns. Ind. Eng. Chem. Process Des. Dev. 1974, 13, 84–91. [Google Scholar] [CrossRef]
  286. Martín, M.; Montes, F.J.; Galán, M.A. Physical explanation of the empirical coefficients of gas–liquid mass transfer equations. Chem. Eng. Sci. 2009, 64, 410–425. [Google Scholar] [CrossRef]
  287. Deckwer, W.D.; Schumpe, A. Improved tools for bubble column reactor design and scale-up. Chem. Eng. Sci. 1993, 48, 889–911. [Google Scholar] [CrossRef]
  288. Nedeltchev, S.; Jordan, U.; Schumpe, A. Correction of the penetration theory based on mass-transfer data from bubble columns operated in the homogeneous regime under high pressure. Chem. Eng. Sci. 2007, 62, 6263–6273. [Google Scholar] [CrossRef]
  289. Wang, T.; Wang, J. Numerical simulations of gas–liquid mass transfer in bubble columns with a CFD–PBM coupled model. Chem. Eng. Sci. 2007, 62, 7107–7118. [Google Scholar] [CrossRef]
  290. Krauβ, M.; Rzehak, R. Reactive absorption of CO2 in NaOH: Detailed study of enhancement factor models. Chem. Eng. Sci. 2017, 166, 193–209. [Google Scholar] [CrossRef]
  291. Rzehak, R.; Krepper, E. Euler-Euler simulation of mass-transfer in bubbly flows. Chem. Eng. Sci. 2016, 155, 459–468. [Google Scholar] [CrossRef]
  292. Vik, C.B.; Solsvik, J.; Hillestad, M.; Jakobsen, H.A. A multifluid-PBE model for simulation of mass transfer limited processes operated in bubble columns. Comput. Chem. Eng. 2018, 110, 115–139. [Google Scholar] [CrossRef]
  293. Lemoine, R.; Morsi, B.I. An algorithm for predicting the hydrodynamic and mass transfer parameters in agitated reactors. Chem. Eng. J. 2005, 114, 9–31. [Google Scholar] [CrossRef]
  294. Sauer, T.; Hempel, D.-C. Fluid dynamics and mass transfer in a bubble column with suspended particles. Chem. Eng. Technol. 1987, 10, 180–189. [Google Scholar] [CrossRef]
  295. Lochiel, A.C.; Calderbank, P.H. Mass transfer in the continuous phase around axisymmetric bodies of revolution. Chem. Eng. Sci. 1964, 19, 471–484. [Google Scholar] [CrossRef]
  296. Nedeltchev, S.; Nigam, K.D.P.; Schumpe, A. Prediction of mass transfer coefficients in a slurry bubble column based on the geometrical characteristics of bubbles. Chem. Eng. Sci. 2014, 106, 119–125. [Google Scholar] [CrossRef]
  297. Nedeltchev, S. Theoretical prediction of mass transfer coefficients in both gas–liquid and slurry bubble columns. Chem. Eng. Sci. 2017, 157, 169–181. [Google Scholar] [CrossRef]
  298. Higbie, R. The rate of absorption of a pure gas into a still liquid during short periods of exposure. Trans. AIChE 1935, 31, 365–389. [Google Scholar]
  299. Calderbank, P.H.; Moo-Young, M.B. The continuous phase heat and mass-transfer properties of dispersions. Chem. Eng. Sci. 1961, 16, 39–54. [Google Scholar] [CrossRef]
  300. Calderbank, P.H.; Johnson, D.S.L.; Loudon, J. Mechanics and mass transfer of single bubbles in free rise through some Newtonian and non-Newtonian liquids. Chem. Eng. Sci. 1970, 25, 235–256. [Google Scholar] [CrossRef]
  301. Weber, M.E. The effect of surface active agents on mass transfer from spherical cap bubbles. Chem. Eng. Sci. 1975, 30, 1507–1510. [Google Scholar] [CrossRef]
  302. Kawase, Y.; Halard, B.; Moo-Young, M. Theoretical prediction of volumetric mass transfer coefficients in bubble columns for Newtonian and non-Newtonian fluids. Chem. Eng. Sci. 1987, 42, 1609–1617. [Google Scholar] [CrossRef]
  303. Schumpe, A.; Serpemen, Y.; Deckwer, W.D. Effective application of bubble columns. Ger. Chem. Eng. 1979, 2, 234–241. [Google Scholar]
  304. Vandu, C.O.; Krishna, R. Influence of scale on the volumetric mass transfer coefficients in bubble columns. Chem. Eng. Process. Process Intensif. 2004, 43, 575–579. [Google Scholar] [CrossRef]
  305. Deckwer, W.D.; Burckhart, R.; Zoll, G. Mixing and mass transfer in tall bubble columns. Chem. Eng. Sci. 1974, 29, 2177–2188. [Google Scholar] [CrossRef]
  306. Hikita, H.; Asai, S.; Tanigawa, K.; Segawa, K.; Kitao, M. The volumetric liquid-phase mass transfer coefficient in bubble columns. Chem. Eng. J. 1981, 22, 61–69. [Google Scholar] [CrossRef]
  307. Merchuk, J.C.; Ben-Zvi, S. A novel approach to the correlation of mass transfer rates in bubble columns with non-Newtonian liquids. Chem. Eng. Sci. 1992, 47, 3517–3523. [Google Scholar] [CrossRef]
  308. Dudley, J. Mass transfer in bubble columns: A comparison of correlations. Water Res. 1995, 29, 1129–1138. [Google Scholar] [CrossRef]
  309. Deckwer, W.; Schumpe, A. Bubble columns—The state of the art and current trends. Int. Chem. Eng. 1987, 27, 405–422. [Google Scholar]
  310. Nakanoh, M.; Yoshida, F. Gas Absorption by Newtonian and Non-Newtonian Liquids in a Bubble Column. Ind. Eng. Chem. Process. Des. Dev. 1980, 19, 190–195. [Google Scholar] [CrossRef]
  311. Suh, I.S.; Schumpe, A.; Deckwer, W.D.; Kulicke, W.M. Gas-liquid mass transfer in the bubble column with viscoelastic liquid. Can. J. Chem. Eng. 1991, 69, 506–512. [Google Scholar] [CrossRef]
  312. Zhao, M.; Niranjan, K.; Davidson, J.F. Mass transfer to viscous liquids in bubble columns and air-lift reactors: Influence of baffles. Chem. Eng. Sci. 1994, 49, 2359–2369. [Google Scholar] [CrossRef]
  313. Boyer, C.; Duquenne, A.-M.; Wild, G. Measuring techniques in gas–liquid and gas–liquid–solid reactors. Chem. Eng. Sci. 2002, 57, 3185–3215. [Google Scholar] [CrossRef]
  314. Jakobsen, H.A. Chemical reactor modeling: Multiphase reactive flow. In Multiphase Reactive Flows; Springer: Berlin, Germany, 2014. [Google Scholar]
  315. Zuber, N.; Findlay, J.A. Average Volumetric Concentration in Two-Phase Flow Systems. J. Heat Transf. 1965, 87, 453–468. [Google Scholar] [CrossRef]
  316. Gourich, B.; Vial, C.; Essadki, A.H.; Allam, F.; Belhaj Soulami, M.; Ziyad, M. Identification of flow regimes and transition points in a bubble column through analysis of differential pressure signal—Influence of the coalescence behavior of the liquid phase. Chem. Eng. Process. Process Intensif. 2006, 45, 214–223. [Google Scholar] [CrossRef]
  317. Wallis, G.B. One-Dimensional Two-Phase Flow; McGraw-Hill: New York, NY, USA, 1969. [Google Scholar]
  318. Vial, C.; Camarasa, E.; Poncin, S.; Wild, G.; Midoux, N.; Bouillard, J. Study of hydrodynamic behaviour in bubble columns and external loop airlift reactors through analysis of pressure fluctuations. Chem. Eng. Sci. 2000, 55, 2957–2973. [Google Scholar] [CrossRef]
  319. Fan, L.T.; Kang, Y.; Neogi, D.; Yashima, M. Fractal analysis of fluidized particle behavior in liquid-solid fluidized beds. AIChE J. 1993, 39, 513–517. [Google Scholar] [CrossRef]
  320. Ellis, N.; Briens, L.A.; Grace, J.R.; Bi, H.T.; Lim, C.J. Characterization of dynamic behaviour in gas–solid turbulent fluidized bed using chaos and wavelet analyses. Chem. Eng. J. 2003, 96, 105–116. [Google Scholar] [CrossRef]
  321. Lu, X.; Li, H. Wavelet analysis of pressure fluctuation signals in a bubbling fluidized bed. Chem. Eng. J. 1999, 75, 113–119. [Google Scholar] [CrossRef]
  322. Drahoš, J.; Bradka, F.; Punčochář, M. Fractal behaviour of pressure fluctuations in a bubble column. Chem. Eng. Sci. 1992, 47, 4069–4075. [Google Scholar] [CrossRef]
  323. Briens, C.L.; Briens, L.A.; Hay, J.; Hudson, C.; Margaritis, A. Hurst’s Analysis to Detect Minimum Fluidization and Gas Maldistribution in Fluidized Beds. AIChE J. 1997, 43, 1904–1908. [Google Scholar] [CrossRef]
  324. Bai, D.; Bi, H.T.; Grace, J.R. Chaotic Behavior of Fluidized Beds Based on Pressure and Voidage Fluctuations. AIChE J. 1997, 43, 1357–1361. [Google Scholar] [CrossRef]
  325. Marzocchella, A.; Zijerveld, R.C.; Schouten, J.C.; Van Den Bleek, C.M. Chaotic Behavior of Gas-Solids Flow in the Riser of a Laboratory-Scale Circulating Fluidized Bed. AIChE J. 1997, 43, 1458–1468. [Google Scholar] [CrossRef]
  326. van den Bleek, C.M.; Schouten, J.C. Deterministic chaos: A new tool in fluidized bed design and operation. Chem. Eng. J. BioChem. Eng. J. 1993, 53, 75–87. [Google Scholar] [CrossRef]
  327. Ajbar, A.; Al-Masry, W.; Ali, E. Prediction of flow regimes transitions in bubble columns using passive acoustic measurements. Chem. Eng. Process. Process Intensif. 2009, 48, 101–110. [Google Scholar] [CrossRef]
  328. Cassanello, M.; Larachi, F.; Kemoun, A.; Al-Dahhan, M.H.; Dudukovic, M.P. Inferring liquid chaotic dynamics in bubble columns using CARPT. Chem. Eng. Sci. 2001, 56, 6125–6134. [Google Scholar] [CrossRef]
  329. Kikuchi, R.; Yano, T.; Tsutsumi, A.; Yoshida, K.; Punchochar, M.; Drahos, J. Diagnosis of chaotic dynamics of bubble motion in a bubble column. Chem. Eng. Sci. 1997, 52, 3741–3745. [Google Scholar] [CrossRef]
  330. Letzel, H.M.; Schouten, J.C.; Krishna, R.; van den Bleek, C.M. Characterization of regimes and regime transitions in bubble columns by chaos analysis of pressure signals. Chem. Eng. Sci. 1997, 52, 4447–4459. [Google Scholar] [CrossRef]
  331. Lin, T.J.; Juang, R.C.; Chen, Y.C.; Chen, C.C. Predictions of flow transitions in a bubble column by chaotic time series analysis of pressure fluctuation signals. Chem. Eng. Sci. 2001, 56, 1057–1065. [Google Scholar] [CrossRef]
  332. Nedeltchev, S.; Kumar, S.B.; Dudukovic, M.P. Flow regime identification in a bubble column based on both Kolmogorov entropy and quality of mixedness derived from CARPT data. Can. J. Chem. Eng. 2003, 81, 367–374. [Google Scholar] [CrossRef]
  333. Nedeltchev, S.; Shaikh, A.; Al-Dahhan, M. Flow regime identification in a bubble column based on both statistical and chaotic parameters applied to computed tomography data. Chem. Eng. Technol. 2006, 29, 1054–1060. [Google Scholar] [CrossRef]
  334. Tchowa Medjiade, W.; Rosenbaum Alvaro, A.; Schumpe, A. Flow regime transitions in a bubble column. Chem. Eng. Sci. 2017, 170, 263–269. [Google Scholar] [CrossRef]
  335. Zhong, W.; Wang, X.; Qianjun, L.I.; Jin, B.; Zhang, M.; Xiao, R.; Huang, Y. Analysis on chaotic nature of a pressurized spout-fluid bed by information theory based shannon entropy. Can. J. Chem. Eng. 2009, 87, 220–227. [Google Scholar] [CrossRef]
  336. Kang, Y.; Woo, K.J.; Ko, M.H.; Cho, Y.J.; Kim, S.D. Particle Flow Behavior in Three-Phase Fluidized Beds. Korean J. Chem. Eng. 1999, 16, 784–788. [Google Scholar] [CrossRef]
  337. Shiea, M.; Mostoufi, N.; Sotudeh-Gharebagh, R. Comprehensive study of regime transitions throughout a bubble column using resistivity probe. Chem. Eng. Sci. 2013, 100, 15–22. [Google Scholar] [CrossRef]
  338. Rodrigues, R.T.; Rubio, J. New basis for measuring the size distribution of bubbles. Miner. Eng. 2003, 16, 757–765. [Google Scholar] [CrossRef]
  339. Busciglio, A.; Grisafi, F.; Scargiali, F.; Brucato, A. On the measurement of local gas hold-up and interfacial area in gas–liquid contactors via light sheet and image analysis. Chem. Eng. Sci. 2010, 65, 3699–3708. [Google Scholar] [CrossRef]
  340. Xu, C.; Shepard, T. Digital Image Processing Algorithm for Determination and Measurement of In-Focus Spherical Bubbles. In Proceedings of the ASME 2014 4th Joint US-European Fluids Engineering Division Summer Meeting collocated with the ASME 2014 12th International Conference on Nanochannels, Microchannels, and Minichannels, Chicago, IL, USA, 3–7 August 2014; pp. V01BT22A002–V001BT022A002. [Google Scholar]
  341. Lau, Y.M.; Möller, F.; Hampel, U.; Schubert, M. Ultrafast X-ray tomographic imaging of multiphase flow in bubble columns–Part 2: Characterisation of bubbles in the dense regime. Int. J. Multiph. Flow 2018. [Google Scholar] [CrossRef]
  342. Lau, Y.M.; Hampel, U.; Schubert, M. Ultrafast X-ray tomographic imaging of multiphase flow in bubble columns–Part 1: Image processing and reconstruction comparison. Int. J. Multiph. Flow 2018. [Google Scholar] [CrossRef]
  343. Azizi, S.; Yadav, A.; Lau, Y.M.; Hampel, U.; Roy, S.; Schubert, M. On the experimental investigation of gas-liquid flow in bubble columns using ultrafast X-ray tomography and radioactive particle tracking. Chem. Eng. Sci. 2017, 170, 320–331. [Google Scholar] [CrossRef]
  344. Adetunji, O.; Rawatlal, R. Estimation of bubble column hydrodynamics: Image-based measurement method. Flow Meas. Instrum. 2017, 53, 4–17. [Google Scholar] [CrossRef]
  345. Guan, X.; Yang, N. Bubble properties measurement in bubble columns: From homogeneous to heterogeneous regime. Chem. Eng. Res. Des. 2017, 127, 103–112. [Google Scholar] [CrossRef]
  346. Hernandez-Alvarado, F.; Kalaga, D.V.; Turney, D.; Banerjee, S.; Joshi, J.B.; Kawaji, M. Void fraction, bubble size and interfacial area measurements in co-current downflow bubble column reactor with microbubble dispersion. Chem. Eng. Sci. 2017, 168, 403–413. [Google Scholar] [CrossRef]
  347. Nedeltchev, S.; Hampel, U.; Schubert, M. Extraction of information and reconstruction entropies from ultrafast X-ray tomography data in a bubble column. Chem. Eng. Sci. 2017, 170, 225–233. [Google Scholar] [CrossRef]
  348. Murgan, I.; Bunea, F.; Ciocan, G.D. Experimental PIV and LIF characterization of a bubble column flow. Flow Meas. Instrum. 2017, 54, 224–235. [Google Scholar] [CrossRef]
  349. Möller, F.; Seiler, T.; Lau, Y.M.; Weber, M.; Weber, M.; Hampel, U.; Schubert, M. Performance comparison between different sparger plate orifice patterns: Hydrodynamic investigation using ultrafast X-ray tomography. Chem. Eng. J. 2017, 316, 857–871. [Google Scholar] [CrossRef]
  350. Wen, J.; Sun, Q.; Sun, Z.; Gu, H. An improved image processing technique for determination of volume and surface area of rising bubble. Int. J. Multiph. Flow 2018. [Google Scholar] [CrossRef]
  351. Zaruba, A.; Krepper, E.; Prasser, H.M.; Schleicher, E. Measurement of bubble velocity profiles and turbulent diffusion coefficients of the gaseous phase in rectangular bubble column using image processing. Exp. Therm. Fluid Sci. 2005, 29, 851–860. [Google Scholar] [CrossRef]
  352. Karn, A.; Ellis, C.; Arndt, R.; Hong, J. An integrative image measurement technique for dense bubbly flows with a wide size distribution. Chem. Eng. Sci. 2015, 122, 240–249. [Google Scholar] [CrossRef]
  353. Rodríguez-Rodríguez, J.; Martínez-Bazán, C.; Montañes, J.L. A novel particle tracking and break-up detection algorithm: Application to the turbulent break-up of bubbles. Meas. Sci. Technol. 2003, 14, 1328. [Google Scholar] [CrossRef]
  354. Lecuona, A.; Sosa, P.A.; Rodríguez, P.A.; Zequeira, R.I. Volumetric characterization of dispersed two-phase flows by digital image analysis. Meas. Sci. Technol. 2000, 11, 1152. [Google Scholar] [CrossRef]
  355. Bian, Y.; Dong, F.; Zhang, W.; Wang, H.; Tan, C.; Zhang, Z. 3D reconstruction of single rising bubble in water using digital image processing and characteristic matrix. Particuology 2013, 11, 170–183. [Google Scholar] [CrossRef]
  356. Sahagian, D.L.; Proussevitch, A.A. 3D particle size distributions from 2D observations: Stereology for natural applications. J. Volcanol. Geotherm. Res. 1998, 84, 173–196. [Google Scholar] [CrossRef]
  357. Lau, Y.M.; Deen, N.G.; Kuipers, J.A.M. Development of an image measurement technique for size distribution in dense bubbly flows. Chem. Eng. Sci. 2013, 94, 20–29. [Google Scholar] [CrossRef]
  358. Lage, P.L.C.; Espósito, R.O. Experimental determination of bubble size distributions in bubble columns: Prediction of mean bubble diameter and gas hold up. Powder Technol. 1999, 101, 142–150. [Google Scholar] [CrossRef]
  359. Solsvik, J.; Jakobsen Hugo, A. Single Air Bubble Breakup Experiments in Stirred Water Tank. Int. J. Chem. React. Eng. 2015, 13, 477–497. [Google Scholar] [CrossRef]
  360. Honkanen, M.; Saarenrinne, P.; Stoor, T.; Niinimäki, J. Recognition of highly overlapping ellipse-like bubble images. Meas. Sci. Technol. 2005, 16, 1760–1770. [Google Scholar] [CrossRef]
  361. Rakoczy, R.; Masiuk, S. Experimental study of bubble size distribution in a liquid column exposed to a rotating magnetic field. Chem. Eng. Process. Process Intensif. 2009, 48, 1229–1240. [Google Scholar] [CrossRef]
  362. Hanselmann, W.; Windhab, E. Flow characteristics and modelling of foam generation in a continuous rotor/stator mixer. J. Food Eng. 1998, 38, 393–405. [Google Scholar] [CrossRef]
  363. Aloufi, F.M. An Investigation of Gas Void Fraction and Transition Conditions for Two-Phase Flow in an Annular Gap Bubble Column. Ph.D. Thesis, Loughborough University, Loughborough, UK, 2011. [Google Scholar]
  364. Hernandez-Alvarado, F.; Kleinbart, S.; Kalaga, D.V.; Banerjee, S.; Joshi, J.B.; Kawaji, M. Comparison of void fraction measurements using different techniques in two-phase flow bubble column reactors. Int. J. Multiph. Flow 2018, 102, 119–129. [Google Scholar] [CrossRef]
  365. Singh, B.K.; Quiyoom, A.; Buwa, V.V. Dynamics of gas–liquid flow in a cylindrical bubble column: Comparison of electrical resistance tomography and voidage probe measurements. Chem. Eng. Sci. 2017, 158, 124–139. [Google Scholar] [CrossRef]
  366. Chabot, J.; Farag, H.; de Lasa, H. Fluid dynamics of bubble columns at elevated temperature modelling and investigation with refractive fiber optic sensors. Chem. Eng. J. 1998, 70, 105–113. [Google Scholar] [CrossRef]
  367. Chaumat, H.; Billet-Duquenne, A.M.; Augier, F.; Mathieu, C.; Delmas, H. On the reliability of an optical fibre probe in bubble column under industrial relevant operating conditions. Exp. Therm. Fluid Sci. 2007, 31, 495–504. [Google Scholar] [CrossRef] [Green Version]
  368. Magaud, F.; Souhar, M.; Wild, G.; Boisson, N. Experimental study of bubble column hydrodynamics. Chem. Eng. Sci. 2001, 56, 4597–4607. [Google Scholar] [CrossRef]
  369. Moujaes, S.F. Testing of a spherical dual-tipped optical fiber probe for local measurements of void fraction and gas velocity in two-phase flows. Can. J. Chem. Eng. 1990, 68, 504–510. [Google Scholar] [CrossRef]
  370. Lichti, M.; Bart, H.-J. Bubble Size Distributions with a Shadowgraphic Optical Probe. Flow Meas. Instrum. 2018. [Google Scholar] [CrossRef]
  371. Tyagi, P.; Buwa, V.V. Experimental characterization of dense gas–liquid flow in a bubble column using voidage probes. Chem. Eng. J. 2017, 308, 912–928. [Google Scholar] [CrossRef]
  372. Vejražka, J.; Večeř, M.; Orvalho, S.; Sechet, P.; Ruzicka, M.C.; Cartellier, A. Measurement accuracy of a mono-fiber optical probe in a bubbly flow. Int. J. Multiph. Flow 2010, 36, 533–548. [Google Scholar] [CrossRef]
  373. Barrau, E.; Rivière, N.; Poupot, C.; Cartellier, A. Single and double optical probes in air-water two-phase flows: Real time signal processing and sensor performance. Int. J. Multiph. Flow 1999, 25, 229–256. [Google Scholar] [CrossRef]
  374. Chang, K.-A.; Lim, H.-J.; Su, C.B. Fiber optic reflectometer for velocity and fraction ratio measurements in multiphase flows. Rev. Sci. Instrum. 2003, 74, 3559–3565. [Google Scholar] [CrossRef]
  375. Lima Neto, I.; Zhu, D.; Rajaratnam, N. Air Injection in Water with Different Nozzles. J. Environ. Eng. 2008, 134, 283–294. [Google Scholar] [CrossRef]
  376. Kiambi, S.L.; Duquenne, A.-M.; Dupont, J.B.; Colin, C.; Risso, F.; Delmas, H. Measurements of Bubble Characteristics: Comparison Between Double Optical Probe and Imaging. Can. J. Chem. Eng. 2003, 81, 764–770. [Google Scholar] [CrossRef]
  377. Cartellier, A.; Barrau, E. Monofiber optical probes for gas detection and gas velocity measurements: Conical probes. Int. J. Multiph. Flow 1998, 24, 1265–1294. [Google Scholar] [CrossRef]
  378. Chaumat, H.; Billet-Duquenne, A.M.; Augier, F.; Mathieu, C.; Delmas, H. Application of the double optic probe technique to distorted tumbling bubbles in aqueous or organic liquid. Chem. Eng. Sci. 2005, 60, 6134–6145. [Google Scholar] [CrossRef] [Green Version]
  379. Liu, W.; Clark, N.N. Relationships between distributions of chord lengths and distributions of bubble sizes including their statistical parameters. Int. J. Multiph. Flow 1995, 21, 1073–1089. [Google Scholar] [CrossRef]
  380. Clark, N.N.; Turton, R. Chord length distributions related to bubble size distributions in multiphase flows. Int. J. Multiph. Flow 1988, 14, 413–424. [Google Scholar] [CrossRef]
  381. Hu, B.; Angeli, P.; Matar, O.K.; Lawrence, C.J.; Hewitt, G.F. Evaluation of drop size distribution from chord length measurements. AIChE J. 2006, 52, 931–939. [Google Scholar] [CrossRef]
  382. Carrara, M. Indagine Sperimentale su Flussi Bifase in Colonne Verticali. Master’s Thesis, Politecnico di Milano, Milan, Italy, 2014. [Google Scholar]
  383. Rüdisüli, M.; Schildhauer, T.J.; Biollaz, S.M.; Ommen, J.R.V. Monte Carlo simulation of the bubble size distribution in a fluidized bed with intrusive probes. Int. J. Multiph. Flow 2012, 44, 1–14. [Google Scholar] [CrossRef]
  384. Hoang, N.H.; Euh, D.J.; Yun, B.J.; Song, C.H. A new method of relating a chord length distribution to a bubble size distribution for vertical bubbly flows. Int. J. Multiph. Flow 2015, 71, 23–31. [Google Scholar] [CrossRef]
  385. Myers, K.; Duduković, M.; Ramachandran, P. Modelling churn-turbulent bubble columns—I. Liquid-phase mixing. Chem. Eng. Sci. 1987, 42, 2301–2311. [Google Scholar] [CrossRef]
  386. Anderson, K.G.; Rice, R.G. Local turbulence model for predicting circulation rates in bubble columns. AIChE J. 1989, 35, 514–518. [Google Scholar] [CrossRef]
  387. Burns, L.F.; Rice, R.G. Circulation in bubble columns. AIChE J. 1997, 43, 1390–1402. [Google Scholar] [CrossRef]
  388. Wilkinson, P.M.; Haringa, H.; Stokman, F.P.A.; Van Dierendonck, L.L. Liquid mixing in a bubble column under pressure. Chem. Eng. Sci. 1993, 48, 1785–1791. [Google Scholar] [CrossRef]
  389. Kantak, M.V.; Hesketh, R.P.; Kelkar, B.G. Effect of gas and liquid properties on gas phase dispersion in bubble columns. Chem. Eng. J. BioChem. Eng. J. 1995, 59, 91–100. [Google Scholar] [CrossRef]
  390. Dudukovic, M.P.; Toseland, B.A.; Bhatt, B.L. A Two-Compartment Convective-Diffusion Model for Slurry Bubble Column Reactors. Ind. Eng. Chem. Res. 1997, 36, 4670–4680. [Google Scholar] [CrossRef]
  391. Degaleesan, S.; Roy, S.; Kumar, S.B.; Duduković, M.P. Liquid mixing based on convection and turbulent dispersion in bubble columns. Chem. Eng. Sci. 1996, 51, 1967–1976. [Google Scholar] [CrossRef]
  392. Liu, H.; Zhang, Z.; Qiu, C. Buoyancy-driven circulation in bubble columns: Alternative analysis. AIChE J. 1998, 44, 2561–2564. [Google Scholar] [CrossRef]
  393. Gupta, P.; Al-Dahhan, M.H.; Dudukovic, M.P.; Toseland, B.A. Comparison of single- and two-bubble class gas–liquid recirculation models—Application to pilot-plant radioactive tracer studies during methanol synthesis. Chem. Eng. Sci. 2001, 56, 1117–1125. [Google Scholar] [CrossRef]
  394. Shimizu, K.; Takada, S.; Minekawa, K.; Kawase, Y. Phenomenological model for bubble column reactors: Prediction of gas hold-ups and volumetric mass transfer coefficients. Chem. Eng. J. 2000, 78, 21–28. [Google Scholar] [CrossRef]
  395. Jakobsen, H.A.; Lindborg, H.; Dorao, C.A. Modeling of Bubble Column Reactors:  Progress and Limitations. Ind. Eng. Chem. Res. 2005, 44, 5107–5151. [Google Scholar] [CrossRef]
  396. Delnoij, E.; Lammers, F.A.; Kuipers, J.A.M.; van Swaaij, W.P.M. Dynamic simulation of dispersed gas-liquid two-phase flow using a discrete bubble model. Chem. Eng. Sci. 1997, 52, 1429–1458. [Google Scholar] [CrossRef]
  397. Lapin, A.; Lübbert, A. Numerical simulation of the dynamics of two-phase gas—Liquid flows in bubble columns. Chem. Eng. Sci. 1994, 49, 3661–3674. [Google Scholar] [CrossRef]
  398. Buwa, V.V.; Deo, D.S.; Ranade, V.V. Eulerian–Lagrangian simulations of unsteady gas–liquid flows in bubble columns. Int. J. Multiph. Flow 2006, 32, 864–885. [Google Scholar] [CrossRef]
  399. Hu, G.; Celik, I. Eulerian–Lagrangian based large-eddy simulation of a partially aerated flat bubble column. Chem. Eng. Sci. 2008, 63, 253–271. [Google Scholar] [CrossRef]
  400. Besbes, S.; El Hajem, M.; Ben Aissia, H.; Champagne, J.Y.; Jay, J. PIV measurements and Eulerian–Lagrangian simulations of the unsteady gas–liquid flow in a needle sparger rectangular bubble column. Chem. Eng. Sci. 2015, 126, 560–572. [Google Scholar] [CrossRef]
  401. Jain, D.; Lau, Y.M.; Kuipers, J.A.M.; Deen, N.G. Discrete bubble modeling for a micro-structured bubble column. Chem. Eng. Sci. 2013, 100, 496–505. [Google Scholar] [CrossRef]
  402. Ishii, M. Thermo-fluid dynamic theory of two-phase flow. NASA STI/Recon Tech. Rep. A 1975, 75, 29657. [Google Scholar]
  403. Sokolichin, A.; Eigenberger, G. Gas—Liquid flow in bubble columns and loop reactors: Part I. Detailed modelling and numerical simulation. Chem. Eng. Sci. 1994, 49, 5735–5746. [Google Scholar] [CrossRef]
  404. Becker, S.; Sokolichin, A.; Eigenberger, G. Gas—Liquid flow in bubble columns and loop reactors: Part II. Comparison of detailed experiments and flow simulations. Chem. Eng. Sci. 1994, 49, 5747–5762. [Google Scholar] [CrossRef]
  405. Grevskott, S.; Sannæs, B.H.; Duduković, M.P.; Hjarbo, K.W.; Svendsen, H.F. Liquid circulation, bubble size distributions, and solids movement in two- and three-phase bubble columns. Chem. Eng. Sci. 1996, 51, 1703–1713. [Google Scholar] [CrossRef]
  406. Pan, Y.; Dudukovic, M.P.; Chang, M. Dynamic simulation of bubbly flow in bubble columns. Chem. Eng. Sci. 1999, 54, 2481–2489. [Google Scholar] [CrossRef]
  407. Hillmer, G. Experimentelle Untersuchung und Fluiddynamische Modellierung von Suspensionsblasensäulen; Der Technischen Fakultät der Universität Erlangen-Nürnberg: Erlangen, Germany, 1989. [Google Scholar]
  408. Gasche, H.-E. Modellierung von Blasensäulen; Der Technischen Fakultät der Universität Erlangen-Nürnberg: Erlangen, Germany, 1989. [Google Scholar]
  409. Menzel, T. Die Reynolds-Schubspannung als Wesentlicher Parameter zur Modellierungder Strömungsstruktur in Blasensäulen und Airlift-Schlaufenreaktoren; VDI-Verlag: Düsseldorf, Germany, 1990. [Google Scholar]
  410. Torvik. Investigations of 2-and 3-Phase Bubble Columns; The Norwegian Institute of technology: Trondheim, Norway, 1990. [Google Scholar]
  411. Grienberger, J. Untersuchung und Modellierung von Blasensäulen; Der Technischen Fakultät der Universität Erlangen-Nurnberg: Erlangen, Germany, 1992. [Google Scholar]
  412. Jakobsen Hugo, A. On the Modeling and Simulation of Bubble Column Reactors Using a Two-Fluid Model; Der Technischen Fakultät der Universität Erlangen-Nurnberg: Erlangen, Germany, 1993. [Google Scholar]
  413. Pfleger, D.; Gomes, S.; Gilbert, N.; Wagner, H.G. Hydrodynamic simulations of laboratory scale bubble columns fundamental studies of the Eulerian–Eulerian modelling approach. Chem. Eng. Sci. 1999, 54, 5091–5099. [Google Scholar] [CrossRef]
  414. Sokolichin, A.; Eigenberger, G. Applicability of the standard k–ε turbulence model to the dynamic simulation of bubble columns: Part I. Detailed numerical simulations. Chem. Eng. Sci. 1999, 54, 2273–2284. [Google Scholar] [CrossRef]
  415. Mudde, R.F.; Simonin, O. Two-and three-dimensional simulations of a bubble plume using a two-fluid model. Chem. Eng. Sci. 1999, 54, 5061–5069. [Google Scholar] [CrossRef]
  416. Ekambara, K.; Dhotre, M.T.; Joshi, J.B. CFD simulations of bubble column reactors: 1D, 2D and 3D approach. Chem. Eng. Sci. 2005, 60, 6733–6746. [Google Scholar] [CrossRef]
  417. Jakobsen, H.A.; Grevskott, S.; Svendsen, H.F. Modeling of Vertical Bubble-Driven Flows. Ind. Eng. Chem. Res. 1997, 36, 4052–4074. [Google Scholar] [CrossRef]
  418. Sokolichin, A.; Eigenberger, G.; Lapin, A.; Lübert, A. Dynamic numerical simulation of gas-liquid two-phase flows Euler/Euler versus Euler/Lagrange. Chem. Eng. Sci. 1997, 52, 611–626. [Google Scholar] [CrossRef]
  419. Jakobsen Hugo, A. Numerical Convection Algorithms and Their Role in Eulerian CFD Reactor Simulations. Int. J. Chem. React. Eng. 2002, 1. [Google Scholar] [CrossRef]
  420. Laborde-Boutet, C.; Larachi, F.; Dromard, N.; Delsart, O.; Schweich, D. CFD simulation of bubble column flows: Investigations on turbulence models in RANS approach. Chem. Eng. Sci. 2009, 64, 4399–4413. [Google Scholar] [CrossRef]
  421. Oey, R.S.; Mudde, R.F.; van den Akker, H.E.A. Sensitivity study on interfacial closure laws in two-fluid bubbly flow simulations. AIChE J. 2003, 49, 1621–1636. [Google Scholar] [CrossRef]
  422. Ma, T.; Lucas, D.; Ziegenhein, T.; Fröhlich, J.; Deen, N.G. Scale-Adaptive Simulation of a square cross-sectional bubble column. Chem. Eng. Sci. 2015, 131, 101–108. [Google Scholar] [CrossRef]
  423. Ma, T.; Ziegenhein, T.; Lucas, D.; Fröhlich, J. Large eddy simulations of the gas–liquid flow in a rectangular bubble column. Nucl. Eng. Des. Eng. Des. 2016. [Google Scholar] [CrossRef]
  424. Ma, T.; Ziegenhein, T.; Lucas, D.; Krepper, E.; Fröhlich, J. Euler–Euler large eddy simulations for dispersed turbulent bubbly flows. Int. J. Heat Fluid Flow 2015, 56, 51–59. [Google Scholar] [CrossRef]
  425. Liu, Z.; Li, B. Scale-adaptive analysis of Euler-Euler large eddy simulation for laboratory scale dispersed bubbly flows. Chem. Eng. J. 2018, 338, 465–477. [Google Scholar] [CrossRef]
  426. Milelli, M. A numerical analysis of confined turbulent bubble plumes. In Swiss Federal Institute of Technology Zurich; ETH Zurich: Zurich, Switzerland, 2002. [Google Scholar]
  427. Lakehal, D.; Smith, B.L.; Milelli, M. Large-eddy simulation of bubbly turbulent shear flows. J. Turbul. 2002, 3, N25. [Google Scholar] [CrossRef]
  428. Díaz, M.E.; Iranzo, A.; Cuadra, D.; Barbero, R.; Montes, F.J.; Galán, M.A. Numerical simulation of the gas–liquid flow in a laboratory scale bubble column: Influence of bubble size distribution and non-drag forces. Chem. Eng. J. 2008, 139, 363–379. [Google Scholar] [CrossRef]
  429. Krepper, E.; Reddy Vanga, B.N.; Zaruba, A.; Prasser, H.-M.; Lopez de Bertodano, M.A. Experimental and numerical studies of void fraction distribution in rectangular bubble columns. Nucl. Eng. Des. Eng. Des. 2007, 237, 399–408. [Google Scholar] [CrossRef]
  430. Frank, T.; Zwart, P.J.; Krepper, E.; Prasser, H.M.; Lucas, D. Validation of CFD models for mono- and polydisperse air–water two-phase flows in pipes. Nucl. Eng. Des. Eng. Des. 2008, 238, 647–659. [Google Scholar] [CrossRef]
  431. Khan, Z.; Bhusare, V.H.; Joshi, J.B. Comparison of turbulence models for bubble column reactors. Chem. Eng. Sci. 2017, 164, 34–52. [Google Scholar] [CrossRef]
  432. Borchers, O.; Busch, C.; Sokolichin, A.; Eigenberger, G. Applicability of the standard k–ε turbulence model to the dynamic simulation of bubble columns. Part II: Comparison of detailed experiments and flow simulations. Chem. Eng. Sci. 1999, 54, 5927–5935. [Google Scholar] [CrossRef]
  433. Buwa, V.V.; Ranade, V.V. Dynamics of gas–liquid flow in a rectangular bubble column: Experiments and single/multi-group CFD simulations. Chem. Eng. Sci. 2002, 57, 4715–4736. [Google Scholar] [CrossRef]
  434. Cachaza, E.M.; Díaz, M.E.; Montes, F.J.; Galán, M.A. Simultaneous Computational Fluid Dynamics (CFD) Simulation of the Hydrodynamics and Mass Transfer in a Partially Aerated Bubble Column. Ind. Eng. Chem. Res. 2009, 48, 8685–8696. [Google Scholar] [CrossRef]
  435. Guillen, D.P.; Grimmett, T.; Gandrik, A.M.; Antal, S.P. Development of a computational multiphase flow model for Fischer Tropsch synthesis in a slurry bubble column reactor. Chem. Eng. J. 2011, 176–177, 83–94. [Google Scholar] [CrossRef]
  436. Dhotre, M.T.; Niceno, B.; Smith, B.L. Large eddy simulation of a bubble column using dynamic sub-grid scale model. Chem. Eng. J. 2008, 136, 337–348. [Google Scholar] [CrossRef]
  437. Zhang, D.; Deen, N.G.; Kuipers, J.A.M. Numerical simulation of the dynamic flow behavior in a bubble column: A study of closures for turbulence and interface forces. Chem. Eng. Sci. 2006, 61, 7593–7608. [Google Scholar] [CrossRef]
  438. Ekambara, K.; Dhotre, M.T. CFD simulation of bubble column. Nucl. Eng. Des. Eng. Des. 2010, 240, 963–969. [Google Scholar] [CrossRef]
  439. Tabib, M.V.; Roy, S.A.; Joshi, J.B. CFD simulation of bubble column—An analysis of interphase forces and turbulence models. Chem. Eng. J. 2008, 139, 589–614. [Google Scholar] [CrossRef]
  440. Cheung, S.C.P.; Yeoh, G.H.; Tu, J.Y. On the numerical study of isothermal vertical bubbly flow using two population balance approaches. Chem. Eng. Sci. 2007, 62, 4659–4674. [Google Scholar] [CrossRef]
  441. Cheung, S.C.P.; Yeoh, G.H.; Tu, J.Y. On the modelling of population balance in isothermal vertical bubbly flows—Average bubble number density approach. Chem. Eng. Process. Process Intensif. 2007, 46, 742–756. [Google Scholar] [CrossRef]
  442. Duan, X.Y.; Cheung, S.C.P.; Yeoh, G.H.; Tu, J.Y.; Krepper, E.; Lucas, D. Gas–liquid flows in medium and large vertical pipes. Chem. Eng. Sci. 2011, 66, 872–883. [Google Scholar] [CrossRef]
  443. Rzehak, R.; Krepper, E. Closure models for turbulent bubbly flows: A CFD study. Nucl. Eng. Des. Eng. Des. 2013, 265, 701–711. [Google Scholar] [CrossRef]
  444. Rzehak, R.; Krepper, E.; Liao, Y.; Ziegenhein, T.; Kriebitzsch, S.; Lucas, D. Baseline Model for the Simulation of Bubbly Flows. Chem. Eng. Technol. 2015, 38, 1972–1978. [Google Scholar] [CrossRef]
  445. Rzehak, R.; Kriebitzsch, S. Multiphase CFD-simulation of bubbly pipe flow: A code comparison. Int. J. Multiph. Flow 2015, 68, 135–152. [Google Scholar] [CrossRef]
  446. Liao, Y.; Lucas, D.; Krepper, E. Application of new closure models for bubble coalescence and breakup to steam–water vertical pipe flow. Nucl. Eng. Des. Eng. Des. 2014, 279, 126–136. [Google Scholar] [CrossRef]
  447. Liao, Y.; Rzehak, R.; Lucas, D.; Krepper, E. Baseline closure model for dispersed bubbly flow: Bubble coalescence and breakup. Chem. Eng. Sci. 2015, 122, 336–349. [Google Scholar] [CrossRef]
  448. Shi, W.; Yang, N.; Yang, X. A kinetic inlet model for CFD simulation of large-scale bubble columns. Chem. Eng. Sci. 2017, 158, 108–116. [Google Scholar] [CrossRef]
  449. Masood, R.M.A.; Delgado, A. Numerical investigation of the interphase forces and turbulence closure in 3D square bubble columns. Chem. Eng. Sci. 2014, 108, 154–168. [Google Scholar] [CrossRef]
  450. Masood, R.M.A.; Rauh, C.; Delgado, A. CFD simulation of bubble column flows: An explicit algebraic Reynolds stress model approach. Int. J. Multiph. Flow 2014, 66, 11–25. [Google Scholar] [CrossRef]
  451. Colombo, M.; Fairweather, M. Multiphase turbulence in bubbly flows: RANS simulations. Int. J. Multiph. Flow 2015, 77, 222–243. [Google Scholar] [CrossRef]
  452. Pourtousi, M.; Sahu, J.N.; Ganesan, P. Effect of interfacial forces and turbulence models on predicting flow pattern inside the bubble column. Chem. Eng. Process. Process Intensif. 2014, 75, 38–47. [Google Scholar] [CrossRef]
  453. Parekh, J.; Rzehak, R. Euler–Euler multiphase CFD-simulation with full Reynolds stress model and anisotropic bubble-induced turbulence. Int. J. Multiph. Flow 2018, 99, 231–245. [Google Scholar] [CrossRef]
  454. Rzehak, R.; Krepper, E. CFD modeling of bubble-induced turbulence. Int. J. Multiph. Flow 2013, 55, 138–155. [Google Scholar] [CrossRef]
  455. Rzehak, R.; Krepper, E. Bubble-induced turbulence: Comparison of CFD models. Nucl. Eng. Des. Eng. Des. 2013, 258, 57–65. [Google Scholar] [CrossRef]
  456. Ma, T.; Santarelli, C.; Ziegenhein, T.; Lucas, D.; Fröhlich, J. Direct numerical simulation–based Reynolds-averaged closure for bubble-induced turbulence. Phys. Rev. Fluids 2017, 2, 034301. [Google Scholar] [CrossRef]
  457. Guan, X.; Yang, N. CFD simulation of pilot-scale bubble columns with internals: Influence of interfacial forces. Chem. Eng. Res. Des. 2017, 126, 109–122. [Google Scholar] [CrossRef]
  458. Lucas, D.; Krepper, E.; Prasser, H.M. Use of models for lift, wall and turbulent dispersion forces acting on bubbles for poly-disperse flows. Chem. Eng. Sci. 2007, 62, 4146–4157. [Google Scholar] [CrossRef]
  459. Rzehak, R.; Krepper, E.; Lifante, C. Comparative study of wall-force models for the simulation of bubbly flows. Nucl. Eng. Des. Eng. Des. 2012, 253, 41–49. [Google Scholar] [CrossRef]
  460. Deen, N.G.; Solberg, T.; Hjertager, B.H. Large eddy simulation of the Gas–Liquid flow in a square cross-sectioned bubble column. Chem. Eng. Sci. 2001, 56, 6341–6349. [Google Scholar] [CrossRef]
  461. Chen, P.; Sanyal, J.; Duduković, M.P. Numerical simulation of bubble columns flows: Effect of different breakup and coalescence closures. Chem. Eng. Sci. 2005, 60, 1085–1101. [Google Scholar] [CrossRef]
  462. Chen, P.; Sanyal, J.; Dudukovic, M.P. CFD modeling of bubble columns flows: Implementation of population balance. Chem. Eng. Sci. 2004, 59, 5201–5207. [Google Scholar] [CrossRef]
  463. Chen, P.; Duduković, M.P.; Sanyal, J. Three-dimensional simulation of bubble column flows with bubble coalescence and breakup. AIChE J. 2005, 51, 696–712. [Google Scholar] [CrossRef]
  464. Larachi, F.ç.; Desvigne, D.; Donnat, L.; Schweich, D. Simulating the effects of liquid circulation in bubble columns with internals. Chem. Eng. Sci. 2006, 61, 4195–4206. [Google Scholar] [CrossRef]
  465. Krepper, E.; Lucas, D.; Frank, T.; Prasser, H.-M.; Zwart, P.J. The inhomogeneous MUSIG model for the simulation of polydispersed flows. Nucl. Eng. Des. Eng. Des. 2008, 238, 1690–1702. [Google Scholar] [CrossRef]
  466. Díaz, E.M.; Montes, F.J.; Galán, M.A. Influence of the lift force closures on the numerical simulation of bubble plumes in a rectangular bubble column. Chem. Eng. Sci. 2009, 64, 930–944. [Google Scholar] [CrossRef]
  467. Masood, R.M.A.; Khalid, Y.; Delgado, A. Scale adaptive simulation of bubble column flows. Chem. Eng. J. 2015, 262, 1126–1136. [Google Scholar] [CrossRef]
  468. Pourtousi, M.; Zeinali, M.; Ganesan, P.; Sahu, J.N. Prediction of multiphase flow pattern inside a 3D bubble column reactor using a combination of CFD and ANFIS. RSC Adv. 2015, 5, 85652–85672. [Google Scholar] [CrossRef]
  469. Pourtousi, M.; Sahu, J.N.; Ganesan, P.; Shamshirband, S.; Redzwan, G. A combination of computational fluid dynamics (CFD) and adaptive neuro-fuzzy system (ANFIS) for prediction of the bubble column hydrodynamics. Powder Technol. 2015, 274, 466–481. [Google Scholar] [CrossRef]
  470. Ziegenhein, T.; Lucas, D.; Rzehak, R.; Krepper, E. Closure relations for CFD simulation of bubble columns. In Proceedings of the 8th International Conference on Multiphase Flow: ICMF 2013, Jeju, Korea, 26–31 May 2013. [Google Scholar]
  471. Liao, J.; Ziegenhein, T.; Rzehak, R. Bubbly flow in an airlift column: A CFD study. J. Chem. Technol. Biotechnol. 2016, 91, 2904–2915. [Google Scholar] [CrossRef]
  472. Rzehak, R.; Krauß, M.; Kováts, P.; Zähringer, K. Fluid dynamics in a bubble column: New experiments and simulations. Int. J. Multiph. Flow 2017, 89, 299–312. [Google Scholar] [CrossRef]
  473. Ziegenhein, T.; Rzehak, R.; Ma, T.; Lucas, D. Towards a unified approach for modelling uniform and non-uniform bubbly flows. Can. J. Chem. Eng. 2017, 95, 170–179. [Google Scholar] [CrossRef]
  474. Rzehak, R.; Ziegenhein, T.; Kriebitzsch, S.; Krepper, E.; Lucas, D. Unified modeling of bubbly flows in pipes, bubble columns, and airlift columns. Chem. Eng. Sci. 2017, 157, 147–158. [Google Scholar] [CrossRef]
  475. Lehr, F.; Mewes, D. A transport equation for the interfacial area density applied to bubble columns. Chem. Eng. Sci. 2001, 56, 1159–1166. [Google Scholar] [CrossRef]
  476. Adetunji, O.C.; Rawatlal, R. Prediction of bubble size and axial position distribution through hybridization of population balance modelling and dynamic gas disengagement. Flow Meas. Instrum. 2018, 59, 181–193. [Google Scholar] [CrossRef]
  477. Cheng, J.; Li, Q.; Yang, C.; Zhang, Y.; Mao, Z.-S. CFD-PBE simulation of a bubble column in OpenFOAM. Chin. J. Chem. Eng. 2017. [Google Scholar] [CrossRef]
  478. Yang, N.; Xiao, Q. A mesoscale approach for population balance modeling of bubble size distribution in bubble column reactors. Chem. Eng. Sci. 2017, 170, 241–250. [Google Scholar] [CrossRef]
  479. Guo, K.; Wang, T.; Liu, Y.; Wang, J. CFD-PBM simulations of a bubble column with different liquid properties. Chem. Eng. J. 2017, 329, 116–127. [Google Scholar] [CrossRef]
  480. Saleh, S.N.; Mohammed, A.A.; Al-Jubory, F.K.; Barghi, S. CFD assesment of uniform bubbly flow in a bubble column. J. Pet. Sci. Eng. 2018, 161, 96–107. [Google Scholar] [CrossRef]
  481. Besagni, G.; Inzoli, F.; Ziegenhein, T.; Lucas, D. Computational Fluid-Dynamic modeling of the pseudo-homogeneous flow regime in large-scale bubble columns. Chem. Eng. Sci. 2017, 160, 144–160. [Google Scholar] [CrossRef]
  482. Besagni, G.; Inzoli, F.; Ziegenhein, T.; Lucas, D. The pseudo-homogeneous flow regime in large-scale bubble columns: Experimental benchmark and computational fluid dynamics modeling. Petroleum 2017. [Google Scholar] [CrossRef]
  483. Xu, L.; Yuan, B.; Ni, H.; Chen, C. Numerical Simulation of Bubble Column Flows in Churn-Turbulent Regime: Comparison of Bubble Size Models. Ind. Eng. Chem. Res. 2013, 52, 6794–6802. [Google Scholar] [CrossRef]
  484. Krishna, R.; van Baten, J.M.; Urseanu, M.I. Three-phase Eulerian simulations of bubble column reactors operating in the churn-turbulent regime: A scale up strategy. Chem. Eng. Sci. 2000, 55, 3275–3286. [Google Scholar] [CrossRef]
  485. van Baten, J.M.; Krishna, R. Eulerian simulations for determination of the axial dispersion of liquid and gas phases in bubble columns operating in the churn-turbulent regime. Chem. Eng. Sci. 2001, 56, 503–512. [Google Scholar] [CrossRef]
  486. van Baten, J.M.; Krishna, R. CFD Simulations of a Bubble Column Operating in the Homogeneous and Heterogeneous Flow Regimes. Chem. Eng. Technol. 2002, 25, 1081–1086. [Google Scholar] [CrossRef]
  487. Krishna, R.; van Baten, J.M. Eulerian simulations of bubble columns operating at elevated pressures in the churn turbulent flow regime. Chem. Eng. Sci. 2001, 56, 6249–6258. [Google Scholar] [CrossRef]
  488. Krepper, E.; Lucas, D.; Prasser, H.-M. On the modelling of bubbly flow in vertical pipes. Nucl. Eng. Des. Eng. Des. 2005, 235, 597–611. [Google Scholar] [CrossRef]
  489. Lucas, D.; Tomiyama, A. On the role of the lateral lift force in poly-dispersed bubbly flows. Int. J. Multiph. Flow 2011, 37, 1178–1190. [Google Scholar] [CrossRef]
  490. Sporleder, F.; Dorao, C.A.; Jakobsen, H.A. Model based on population balance for the simulation of bubble columns using methods of the least-square type. Chem. Eng. Sci. 2011, 66, 3133–3144. [Google Scholar] [CrossRef]
  491. Colella, D.; Vinci, D.; Bagatin, R.; Masi, M.; Bakr, E.A. A study on coalescence and breakage mechanisms in three different bubble columns. Chem. Eng. Sci. 1999, 54, 4767–4777. [Google Scholar] [CrossRef]
  492. Ramkrishna, D.; Mahoney, A.W. Population balance modeling. Promise for the future. Chem. Eng. Sci. 2002, 57, 595–606. [Google Scholar] [CrossRef]
  493. Solsvik, J.; Jakobsen, H.A. A review of the statistical turbulence theory required extending the population balance closure models to the entire spectrum of turbulence. AIChE J. 2016, 62, 1795–1820. [Google Scholar] [CrossRef]
  494. Solsvik, J.; Jakobsen, H.A. Development of Fluid Particle Breakup and Coalescence Closure Models for the Complete Energy Spectrum of Isotropic Turbulence. Ind. Eng. Chem. Res. 2016, 55, 1449–1460. [Google Scholar] [CrossRef]
  495. Solsvik, J.; Jakobsen, H.A. Bubble Coalescence Modeling in the Population Balance Framework. J. Dispers. Sci. Technol. 2014, 35, 1626–1642. [Google Scholar] [CrossRef]
  496. Solsvik, J.; Tangen, S.; Jakobsen, H.A. On the Constitutive Equations for Fluid Particle Breakage. Rev. Chem. Eng. 2013, 29, 241. [Google Scholar] [CrossRef]
  497. Lehr, F.; Millies, M.; Mewes, D. Bubble-Size distributions and flow fields in bubble columns. AIChE J. 2002, 48, 2426–2443. [Google Scholar] [CrossRef]
  498. Howarth, W. Coalescence of drops in a turbulent flow field. Chem. Eng. Sci. 1964, 19, 33–38. [Google Scholar] [CrossRef]
  499. Shinnar, R.; Church, J.M. Statistical theories of turbulence in predicting particle size in agitated dispersions. Ind. Eng. Chem. 1960, 52, 253–256. [Google Scholar] [CrossRef]
  500. Ishii, M.; Kojasoy, G. Interfacial area transport equation and preliminary considerations for closure relations. In Technical Report, PU-NE-93/6; Nuclear Engineering Department, Purdue University West Lafayette: West Lafayette, IN, USA, 1993. [Google Scholar]
  501. Liao, Y. Development and Validation of Models for Bubble Coalescence and Breakup. Ph.D. Thesis, Technische University Dresden, Dresden, Germany, 2013. [Google Scholar]
  502. Solsvik, J.; Maaß, S.; Jakobsen, H.A. Definition of the Single Drop Breakup Event. Ind. Eng. Chem. Res. 2016, 55, 2872–2882. [Google Scholar] [CrossRef]
Figure 1. The multi-scale approach to study bubble column fluid dynamics.
Figure 1. The multi-scale approach to study bubble column fluid dynamics.
Chemengineering 02 00013 g001
Figure 2. The main processes involved in the reactive mass transfer phenomena.
Figure 2. The main processes involved in the reactive mass transfer phenomena.
Chemengineering 02 00013 g002
Figure 3. Flow regime transitions from the homogeneous flow regime towards the transition flow regime.
Figure 3. Flow regime transitions from the homogeneous flow regime towards the transition flow regime.
Chemengineering 02 00013 g003
Figure 4. Influence of the aspect ratio (AR) on flow regime transition points—data obtained by [28].
Figure 4. Influence of the aspect ratio (AR) on flow regime transition points—data obtained by [28].
Chemengineering 02 00013 g004
Figure 5. “Fine gas sparger”.
Figure 5. “Fine gas sparger”.
Chemengineering 02 00013 g005
Figure 6. “Coarse gas sparger”.
Figure 6. “Coarse gas sparger”.
Chemengineering 02 00013 g006
Figure 7. Influence of UL on flow regime transition points—data obtained by Besagni et al. [34,46,51,52,53,54].
Figure 7. Influence of UL on flow regime transition points—data obtained by Besagni et al. [34,46,51,52,53,54].
Chemengineering 02 00013 g007
Figure 8. Influence of AR and UL on flow regime transition points—data obtained by [28].
Figure 8. Influence of AR and UL on flow regime transition points—data obtained by [28].
Chemengineering 02 00013 g008
Figure 9. Influence of the liquid phase on flow regime transition points—ref. [12,14].
Figure 9. Influence of the liquid phase on flow regime transition points—ref. [12,14].
Chemengineering 02 00013 g009
Figure 10. Influence of AR and n* on flow regime transition points—Data obtained from ref. [28].
Figure 10. Influence of AR and n* on flow regime transition points—Data obtained from ref. [28].
Chemengineering 02 00013 g010
Figure 11. Influence of AR and n* (as defined in Equation (2) on flow regime transition points—data obtained from ref. [12].
Figure 11. Influence of AR and n* (as defined in Equation (2) on flow regime transition points—data obtained from ref. [12].
Chemengineering 02 00013 g011
Figure 12. Flow regime maps from the previous literature.
Figure 12. Flow regime maps from the previous literature.
Chemengineering 02 00013 g012aChemengineering 02 00013 g012b
Figure 13. Flow regime maps.
Figure 13. Flow regime maps.
Chemengineering 02 00013 g013
Figure 14. Literature studies.
Figure 14. Literature studies.
Chemengineering 02 00013 g014
Figure 15. Literature studies.
Figure 15. Literature studies.
Chemengineering 02 00013 g015
Figure 16. Pipe sparger in open tube configuration—data from ref. [34].
Figure 16. Pipe sparger in open tube configuration—data from ref. [34].
Chemengineering 02 00013 g016
Figure 17. Pipe sparger in annular gap configuration—data from ref. [34].
Figure 17. Pipe sparger in annular gap configuration—data from ref. [34].
Chemengineering 02 00013 g017
Figure 18. Spider sparger—data from ref. [46].
Figure 18. Spider sparger—data from ref. [46].
Chemengineering 02 00013 g018
Figure 19. Influence of AR in large diameter bubble columns with spider sparger—data from ref. [28].
Figure 19. Influence of AR in large diameter bubble columns with spider sparger—data from ref. [28].
Chemengineering 02 00013 g019aChemengineering 02 00013 g019b
Figure 20. Influence of the aspect ratio in large diameter bubble columns—studies from the literature.
Figure 20. Influence of the aspect ratio in large diameter bubble columns—studies from the literature.
Chemengineering 02 00013 g020aChemengineering 02 00013 g020b
Figure 21. Influence of AR in large diameter bubble columns with spider sparger—data from ref. [37].
Figure 21. Influence of AR in large diameter bubble columns with spider sparger—data from ref. [37].
Chemengineering 02 00013 g021
Figure 22. Flow regime maps.
Figure 22. Flow regime maps.
Chemengineering 02 00013 g022
Figure 23. Influence of NaCl on gas hold-up (batch mode)—data from ref. [28].
Figure 23. Influence of NaCl on gas hold-up (batch mode)—data from ref. [28].
Chemengineering 02 00013 g023
Figure 24. Influence of EtOH on gas hold-up—data from ref. [12].
Figure 24. Influence of EtOH on gas hold-up—data from ref. [12].
Chemengineering 02 00013 g024
Figure 25. Influence of the gas superficial velocity (HZDR, Helmholtz-Zentrum Dresden-Rossendorf, bubble columns) on the E-batch mode only.
Figure 25. Influence of the gas superficial velocity (HZDR, Helmholtz-Zentrum Dresden-Rossendorf, bubble columns) on the E-batch mode only.
Chemengineering 02 00013 g025
Figure 26. Influence of the gas and liquid superficial velocities on E (PoliMi bubble columns [53]).
Figure 26. Influence of the gas and liquid superficial velocities on E (PoliMi bubble columns [53]).
Chemengineering 02 00013 g026
Figure 27. Relationship between Eo and E for different experiments.
Figure 27. Relationship between Eo and E for different experiments.
Chemengineering 02 00013 g027
Figure 28. Influence of the liquid phase properties on the interfacial area—data from ref. [12].
Figure 28. Influence of the liquid phase properties on the interfacial area—data from ref. [12].
Chemengineering 02 00013 g028
Figure 29. Influence of the gas sparger openings on kLa—data taken from Koide et al. [138].
Figure 29. Influence of the gas sparger openings on kLa—data taken from Koide et al. [138].
Chemengineering 02 00013 g029
Figure 30. Influence of the bubble column diameter on kLa—data from Akita and Yoshida [47]−0.15 M Na2SO3—AIR 20 °C.
Figure 30. Influence of the bubble column diameter on kLa—data from Akita and Yoshida [47]−0.15 M Na2SO3—AIR 20 °C.
Chemengineering 02 00013 g030
Figure 31. Influence of the bubble column diameter on kLa—data from Akita and Yoshida [47]—water and O2, 30 °C.
Figure 31. Influence of the bubble column diameter on kLa—data from Akita and Yoshida [47]—water and O2, 30 °C.
Chemengineering 02 00013 g031
Figure 32. Influence of the bubble column diameter on kLa—data from Vandu and Krishna [304].
Figure 32. Influence of the bubble column diameter on kLa—data from Vandu and Krishna [304].
Chemengineering 02 00013 g032
Figure 33. Influence of the operating pressure on kLa—data from Letzel et al. [170].
Figure 33. Influence of the operating pressure on kLa—data from Letzel et al. [170].
Chemengineering 02 00013 g033
Figure 34. Influence of the operating pressure on kLa—data from Kang et al. [179]—even distribution experimental data.
Figure 34. Influence of the operating pressure on kLa—data from Kang et al. [179]—even distribution experimental data.
Chemengineering 02 00013 g034
Figure 35. Influence of the operating pressure on kLa—data from Kang et al. [179]—even distribution experimental data.
Figure 35. Influence of the operating pressure on kLa—data from Kang et al. [179]—even distribution experimental data.
Chemengineering 02 00013 g035
Figure 36. Relationship between kLa and UG for different viscous systems [47,138,173,304,307].
Figure 36. Relationship between kLa and UG for different viscous systems [47,138,173,304,307].
Chemengineering 02 00013 g036
Figure 37. Influence of the gas phase on kLa—data from Ozturk et al. [173].
Figure 37. Influence of the gas phase on kLa—data from Ozturk et al. [173].
Chemengineering 02 00013 g037
Figure 38. Influence of the gas phase on kLa—data from Ozturk et al. [173].
Figure 38. Influence of the gas phase on kLa—data from Ozturk et al. [173].
Chemengineering 02 00013 g038
Figure 39. Influence of the gas phase on kLa—data from Gopal and Sharma [106].
Figure 39. Influence of the gas phase on kLa—data from Gopal and Sharma [106].
Chemengineering 02 00013 g039
Figure 40. Coalescence mechanisms.
Figure 40. Coalescence mechanisms.
Chemengineering 02 00013 g040
Figure 41. Break-up mechanisms.
Figure 41. Break-up mechanisms.
Chemengineering 02 00013 g041
Table 1. Literature studies (reference codes for Figure 14).
Table 1. Literature studies (reference codes for Figure 14).
CodeReferencedc [m]Aspect Ratio [-]Sparger
R1[46]0.2422.1Spider Sparger—d0 = 1–3.5 mm
R2[105]0.466.63Ring Sparger—d0 = 0.5 mm
R3[105]1.072.85Ring Sparger—d0 = 0.76 mm
R4[47]0.15226.32Single Hole—d0 = 5 mm
R5[49]0.0530Single Nozzle—d0 = 5 5 mm
R6[49]0.0530Multiple Nozzle—d0 = 0.65 mm
R7[106]0.24Single Nozzle—d0 = 6 mm
R8[106]0.24Ring Sparger—d0 = 1 mm
R9[106]0.61Ring Sparger—d0 = 2 mm
R10[106]0.61Ring Sparger—d0 = 3 mm
R11[107]0.07313Single Nozzle—d0 = 1.5–2.7–5.7 mm
R12[108]0.316.7Perforated Plate—d0 = 1.5 mm
R13[108]0.316.7Single Sparger—d0 = 25.4 mm
R14[109]0.235.3Multiple Nozzle—d0 = 1 mm
Table 2. Literature studies (reference codes for Figure 15).
Table 2. Literature studies (reference codes for Figure 15).
CodeReferencedc [m]Aspect Ratio [-]Sparger
R1[46]0.2422.1Spider Sparger—d0 = 1–3.5 mm
R2[52]0.24—Annular gap22.1Pipe Sparger—d0 = 3.5 mm
R3[47]0.15226.32Single Hole—d0 = 5 mm
R4[110]0.305-Single Hole—d0 = 1.66 mm
R5[110]0.127-Single Hole—d0 = 1.66 mm
R6[49]0.0530Single Nozzle—d0 = 5 5 mm
R7[111]0.3857Sieve Plate—d0 = 1 mm
R8[111]0.3857Sieve Plate—d0 = 1.5 mm
R9[111]0.3857Sieve Plate—d0 = 3.0 mm
R10[111]0.3857Sieve Plate—d0 = 6.0 mm
R11[112]0.070712–33Single Nozzle—d0 = 2.25–7 mm
R12[112]0.304–6.3Single Nozzle—d0 = 1.48–3.00 mm
R13[108]0.316.7Single Sparger—d0 = 25.4 mm
R14[18]0.312Single Sparger—d0 = 1 mm
Table 3. References codes for Figure 24 data.
Table 3. References codes for Figure 24 data.
CodeDescription
R0cEtOH,wt = 0%—Air-water gas hold-up curve
R1cEtOH,wt = 0.3%—Gas hold-up curve measured after waiting 30 s for every gas hold-up measurement point from low to high gas flow rate: run 1.
R2cEtOH,wt = 0.3%—Gas hold-up curve measured after waiting 30 s for every gas hold-up measurement point from low to high gas flow rate: run 2.
R3cEtOH,wt = 0.3%—Gas hold-up curve measured after waiting 120 s for every gas hold-up measurement point from high to low gas flow rate.
R4cEtOH,wt = 0.3%—Gas holdup curve measured after waiting 120 s for every gas hold-up measurement point after each flow rate increase.
R5cEtOH,wt = 0.3%—Gas hold-up curve when foaming phenomenon was observed: run 1
R6cEtOH,wt = 0.3%—Gas hold-up curve when foaming phenomenon was observed: run 2
R7cEtOH,wt = 0.3%—Gas hold-up curve when foaming phenomenon was observed: run 3
Table 4. Gas dholdup correlations.
Table 4. Gas dholdup correlations.
ReferenceBubble Column DesignGas and Liquid PhasesPhase Properties
Hughmark, 1967 [133]Multi-orifice gas sparger
dc > 0.1 m
UG = 0.004–0.450 m/s
Air-Water; Air-Na2CO3 aq. Soln.; Air-Kerosene; Air-Light oil; Ai-Glycerol aq. soln.; Air-ZnCl2 aq. soln.; Air-Na2SO3 aq. soln.ρL = 0.78–1.7 [g/cm3]
μL = 0.0009–0.152 [Pa∙s]
σ = 0.025–0.076 [N/m]
Kato et al. 1972 [134]dc = 0.066–0.214 m
Hc = 2.01–4.05 m
UG = 0–0.30 m/s
UL = 0–0.015 m/s
Air-Water
Kato and Nishiwaki, 1972 [193]Single-hole gas sparger
d0 = 0.005 m
dc = 0.15–0.60 m
UG = 0.005–0.42 m/s
Air-Water; Air-Glycol aq. soln.; Air-Methanol; Air-CCl4; Air-Na2SO3 aq. soln. (0.15 M); Air-NaCl aq. soln. (0.03 M, 0.07 M, 0.15 M, 0.6 M, 1 M): O2-Water; He-Water; CO2-WaterρL = 0.79–1.59 [g/cm3]
μL = 0.00058–0.0211 [Pa∙s]
σ = 0.022–0.0742 [N/m]
Akita and Yoshida, 1973 [47]d0 = 0.0013–0.00362 m
dc = 0.10 and 0.19 m
Hc = 1.5 and 2.4 m
UG = 0.043–0.338 m/s
Air-Water; Air-8.0 wt% Methanol aq. soln.; Air-15.0 wt% Methanol aq. soln.; Air-53.0 wt% Methanol aq. soln.; Air-35.0 wt% Cane sugar aq. soln.; Air-50.0 wt% Cane sugar aq. soln.ρL = 0.91–1.24 [g/cm3]
μL = 0.001–0.0192 [Pa∙s]
σ = 0.0382–0.0755 [N/m]
Hikita and Kikukawa, 1974 [194] (as reported by [24]).Perforated plates and sintered plates
d0 = 0.3 and 0.005 m
dc = 0.0756–0.61 m
Hc = 0.02–3.5 m
UG = 0.01–0.08 m/s
Air used as gas.
Liquids: water, methanol, iso- and n-propanol, iso- and n-butanol, carbon tetrachloride, dichloroethane, methyl ethyl ketone, ethyl acetate, ethylene glycol, benzene
ρL = 0.8–1.6 [g/cm3]
μL = 0.00043–0.02 [Pa∙s]
σ = 0.0214–0.0728 [N/m]
K = 8×104–5×1010
Gestrich and Rähse, 1975 [195]Perforated plate
d0 = 0.0087–0.0309 m
dc = 0.05–0.10 m
UG = 0.002–0.14 m/s
Air-Water; Air-Glycerol aq. soln. (40%); Air-Kerosene
Reacting system: Air/CO2-aq. NaOH (2M)
ρL = 0.78–1.11 [g/cm3]
μL = 0.00088–0.0115 [Pa∙s]
σ = 0.0312–0.072 [N/m]
Kumar et al., 1976 [196]Perforated plates
d0 = 0.0005 and 0.001 m
dc = 0.10 m
Hc < 2 m
UG = 0.01–0.20 m/s
Air used as gas;
Liquids: n-octanol; tetrabromomethane, glycol; 1,3-butanediol.
ρL = 0.8–2.98 [g/cm3]
μL = (20–100)∙10−3 [Pa∙s]
σ = 21.7–72 [dyn/cm]
Mersmann,1978 [199]Multi-nozzles
d0 = 0.030 m
dc = 5.50 m
H0 = 7.0 m (liquid height)
UG = 0.024–0.128 m/s
Air-Water
Koide et al., 1979 [135]Downflow bubble columnGases: Air, Ar, H2, CCl2F2.
Liquids: Water, CCl4, Glycerol aq. soln., CMC (Carboxymethyl cellulose).
I = 148–336 [kg/m2∙s]
ε* = 0.003–0.24
ρL/ρG = 184–5340
μL/μG = 37–2220
σ = 0.055–0.07 [N/m]
Friedel et al., 1980 [197]Single-nozzle gas sparger
d0 = 0.011 m
dc = 0.10 m
Hc = 1.5 m
UG = 0.042–0.38 m
Pure liquids or non-electrolyte solutions: Air-Water; Air-30 wt% Sucrose; Air-50 wt% Sucrose; Air-Methanol; Air-53 wt% Methanol; Air-nButanol; Air-Aniline; Air-7 wt% iButanol; H2–Water; CO2-Water; CH4-Water; C3H8-Water; H2+N2 (1:1)-Water; H2+N2 (5:1)-Water
Electrolyte solutions: Air-(0.1–5.0 M) NaCl; Air-(0.1–1.5 M) Na2SO4; Air-(0.1–2.0 M) CaCl2; Air-0.4 M MgCl2; Air-(0.1–1.0 M) AlCl3; Air-(0.1–3.0 M) KCl; Air-0.5 M K2SO4; Air-(0.16 M, 0.5 M) K3PO4; Air-0.5 M KNO3
Pure liquids or non-electrolyte solutions
ρL = 0.794–1.24 [g/cm3]
ρG = (0.0837–1.84) 10−3 [g/cm3]
μL = (0.658–17.8)∙10−3 [Pa∙s]
μG = (0.008–0.0181) ∙10−3 [Pa∙s]
σ = 0.0229–0.0759 [N/m]
Electrolyte solutions
ρL = 1.01–1.17 [g/cm3]
μL = 0.009–0.00187 [Pa∙s]
σ = 0.0719–0.0796 [N/m]
Hikita et al., 1980 [80]Porous plate
dc = 0.153 m
Hc = 2.5 m
Air-Distilled water
Iordache and Muntean, 1981 [202]Gas distributor: perforated plate (749 holes,)
d0 = 0.00166 m
dc = 0.305 m
Hc = 2.44 m
Glycerine systems
CMC solutions
Glycerine systems
ρL = 1.010–1.249 [g/cm3]
μL = 0.0013–0.246 [Pa∙s]
CMC solutions
K = 0.0018–2.570
n = 0.495–1.0
ρL = 0.996–1.008 [g/cm3]
Godbole et al., 1982 [152]Single nozzle (d0 = 1.5, 2.7 and 5.7 [mm])
dc = 7.3 [cm]
Hc = 0.95 [m]
Water-N2; Water-He; Water-CO2;; Methanol-N2; NaNO3-N2; NaNO3-He; LiCl-KCl-N2; LiCl-KCl-HeρL = 0.788–1.888 [g/cm3]
μL=(0.45–3.65)×10−3 [Pa∙s]
σ = 0.0215–0.13 [N/m]
Sada et al., 1984 [107]Sintered glass disc
d0 = 0.10 m
dc = 0.10 m
Hc = 1.5 m
UG = 0.001–0.045 m/s
Air-water; Air-NaCl-water (NaCl = 0.25 M); Air-CuCl2-water (CuCl2 = 0.25 M)
T = 303–353 [K]
Grover et al., 1986 [78]dc = 0.30 mAir-Wwater; Air-Varsol(*); Air-trichloroethylene
(*) Varsol DX 3641 is a light hydrocarbon oil available from ESSO Chemicals.
ρL = 0.788–1.450 [g/cm3]
μL = (0.552–1.452) × 10−3 [Pa∙s]
σ = 0.0283–0.0720 [N/m]
Reilly et al., 1986 [108]40-L bubble column
Perforated plate (20 holes) d0 = 0.001 m
dc = 0.23 m
Hc = 1.22 m
1000-L pilot plant fermenter
Ring sparger (100 holes) d0 = 0.003 m
dc = 0.76 m
Hc = 3.21 m
Newtonian liquids: water, glycerine; dextrose aqueous solution; three fermentation media (glucose+mineral salt, molasses+mineral salt, Alpha-floc+mineral salt)
Non-Newtonian fluids: Carboxy-methyl cellulose (CMC7H4, Hercules Inc.),; carboxypolymethylene (Carbopol 941, Goodrich Chemical Co.); and polyacrylamide (Separan NP10, Dow Chemical Co.)
Newtonian liquids
ρL = 0.991–1.009 [g/cm3]
Non-Newtonian fluids
ρL = 0.991–0.993 [g/cm3]
Kawase and Moo-Young, 1987 [207]Single tube (d0 = 0.003 m); ring gas sparger (29 holes, d0 = 0.002 m; ring gas sparger (56 holes, d0 = 0.002 m)
dc = 0.06; 0.14; 0.30 m
Hc = 1.8; 2.2; 2.0 m
Liquids: glycerol, CMC, PAA and Xanthan.ρL = 0.999–1.248 [g/cm3]
σ = 0.0495–0.0720 [N/m]
K = 3.2–9780
n = 0.180–1
Schumpe and Deckwer, 1987 [203]Co-current and counter-current flow
Single nozzle gas sparger d0 = 0.010 m
d0 = 0.10 m
Hc = 1.05 m
UG = 0.01–0.16 m/s
UL = 0.07 m/s
Air-Water; Air-Alcohol; Air-5%NaCl soln.T = 25–96.56 [°C]ρL = 0.7483–1.0268 [g/cm3]
μL = (0.2946–0.8937) × 10−3 [Pa∙s]
σ = 0.01877–0.07197 [N/m]
Zou et al., 1988 [209]Ejector gas sparger
dc = 0.30 m
Hc = 1.46 m
Coalescent batches: distilled water; distilled water & OCENOL; 3% SOKRAT & OCENOL (SOKRAT is a commercial thickener consisting of water and a soluble liquid polymer based on acrylonitrile and acrylic acid in a ratio of 2:1. OCEANOL is a foam breaker consisting of a mixture of saturated and unsaturated alcohol from the fraction C16–C18.) (*); 6% SOKRAT & OCENOL; 10% SOKRAT & OCENOL; 58% Sucrose
Non-coalescent batches: 0.5% SOKRAT; 3% SOKRAT ; 6% SOKRAT; 10% SOKRAT
Coalescent batches
ρL = 0.995–1.270 [g/cm3]
μL = (0.7–25.6) × 10−3 [Pa∙s]
σ = 0.0335–0.0654 [N/m]
Non-coalescent batches
ρL = 0.998–1.011 [g/cm3]
μL = (1.5–24.4) × 10−3 [Pa∙s]
σ = 0.0487–0.0645 [N/m]
Elgozali et al., 2002 [198]Sieve plate gas sparger (25 holes, d0 = 0.005 m and 75 holes, d0 = 0.003 m)
dc = 0.09 m
Hc = 0.61 m
Air used as gas.
Pure liquids: 2-propanol
Binary mixtures: 2-propanol/methanol (20 mol% 2-propanol); 2-propanol/water (15 mol% 2-propanol); ethanol/water; ethylene glycol/water
Table 5. Empirical constants for Equation (15).
Table 5. Empirical constants for Equation (15).
VariableAll BatchesCoalescent BatchesNon-Coalescent Batches
K(4.5 ± 5.9) × 109(1.92 ± 0.74) × 106(5.30 ± 11.70) × 106
a0.67 ± 0.040.72 ± 0.010.44 ± 0.01
b0.22 ± 0.020.14 ± 0.010.13 ± 0.02
c1.95 ± 0.121.26 ± 0.041.41 ± 0.20
Table 6. Correction Factor for the Air–5% NaCl System in Equation (23).
Table 6. Correction Factor for the Air–5% NaCl System in Equation (23).
T [°C]40607080859095
f1.2101.24681.18040.16070.12150.15050.2634
Table 7. Coefficients for aspect ratio correlation (Equation (45)).
Table 7. Coefficients for aspect ratio correlation (Equation (45)).
cwt [%]z1z2z3k1k2z4z5
Air-Water
0−0.6570.0011.000.690−0.2510.750−0.300
Air-Water-MEG
0.05−0.5700.0011.000.691−0.3000.670−0.280
0.1−0.5500.0011.000.701−0.2940.692−0.280
0.5−0.6660.0011.000.674−0.3080.666−0.300
1−0.5600.0011.000.689−0.3210.667−0.300
5−0.4200.0011.000.730−0.2950.735−0.300
8−0.3400.0011.000.744−0.3000.745−0.300
10−0.6250.0011.000.693−0.3850.710−0.300
80−0.3400.0011.000.730−0.2370.703−0.300
Air-Water-EtOH
0.05−0.2820.0011.000.844−0.1400.808−0.100
Air-Water-NaCl
0.4 (c/ct = 0.48)−0.6050.0011.000.697−0.2860.713−0.300
1 (c/ct = 1.17)−0.4850.0011.000.722−0.2840.738−0.300

Share and Cite

MDPI and ACS Style

Besagni, G.; Inzoli, F.; Ziegenhein, T. Two-Phase Bubble Columns: A Comprehensive Review. ChemEngineering 2018, 2, 13. https://doi.org/10.3390/chemengineering2020013

AMA Style

Besagni G, Inzoli F, Ziegenhein T. Two-Phase Bubble Columns: A Comprehensive Review. ChemEngineering. 2018; 2(2):13. https://doi.org/10.3390/chemengineering2020013

Chicago/Turabian Style

Besagni, Giorgio, Fabio Inzoli, and Thomas Ziegenhein. 2018. "Two-Phase Bubble Columns: A Comprehensive Review" ChemEngineering 2, no. 2: 13. https://doi.org/10.3390/chemengineering2020013

Article Metrics