sensors-logo

Journal Browser

Journal Browser

Nitric Oxide Sensors and Their Applications in Biomedical Research

A special issue of Sensors (ISSN 1424-8220). This special issue belongs to the section "Chemical Sensors".

Deadline for manuscript submissions: closed (31 May 2003) | Viewed by 92479

Special Issue Editor


E-Mail Website
Guest Editor
Beijing Key Laboratory of Bioengineering and Sensing Technology, Research Center for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing 100083, China
Interests: electrochemical sensors; biosensors; microelectrodes; nanosensors; free radical sensors; nitric oxide sensors; glucose sensors; DNA sensors; oxygen sensors; ion selective electrodes; gas sensors
Special Issues, Collections and Topics in MDPI journals

Special Issue Information

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Sensors is an international peer-reviewed open access semimonthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2600 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Published Papers (6 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Research

Jump to: Review

571 KiB  
Article
The Utility of the Nitric Oxide Electrochemical Sensor in Biomedical Research
by Roger D. Hurst and John B. Clark
Sensors 2003, 3(8), 321-329; https://doi.org/10.3390/s30800321 - 22 Aug 2003
Cited by 20 | Viewed by 9398
Abstract
In recent years World Precision Instruments Inc. (WPI) produced for commercial use a selective and sensitive electrochemical sensor for the detection of the important biological free radical nitric oxide (NO). Though many kinds of NO sensors are now commercially available WPI offers a [...] Read more.
In recent years World Precision Instruments Inc. (WPI) produced for commercial use a selective and sensitive electrochemical sensor for the detection of the important biological free radical nitric oxide (NO). Though many kinds of NO sensors are now commercially available WPI offers a range of sensors of variable size and applicability for the detection of NO in vivo and in in vitro biomedical samples. This article overviews the working characteristics of the sensors and their utility for biomedical research. Full article
(This article belongs to the Special Issue Nitric Oxide Sensors and Their Applications in Biomedical Research)
Show Figures

Figure 1

240 KiB  
Article
Real Time Microelectrode Measurement of Nitric Oxide in Kidney Tubular Fluid in vivo
by David Z. Levine and Michelle Iacovitti
Sensors 2003, 3(8), 314-320; https://doi.org/10.3390/s30800314 - 22 Aug 2003
Cited by 6 | Viewed by 9347
Abstract
In this review we summarize our experience using a microelectrode to measure nitric oxide concentrations [NO] in living rat kidney tubules. In the anaesthetized living rat, the abdomen can be opened, and the kidney can be placed in a cup such that one [...] Read more.
In this review we summarize our experience using a microelectrode to measure nitric oxide concentrations [NO] in living rat kidney tubules. In the anaesthetized living rat, the abdomen can be opened, and the kidney can be placed in a cup such that one can puncture a surface single tubular segment, 1-2 mm long, connected to one of 30,000 filtering glomeruli. The tubular segment can be viewed with a stereo microscope and punctured using sophisticated micromanipulators. The segment, ranging in diameter from about 15 - 35 um contains freely flowing RBC-free fluid, electrolytes, O2, pCO2 and NO gas concentrations, and a host of other known and unknown substances. After a “pre” puncture with a 7-10 um beveled glass pipette, intratubular [NO] can be directly determined by inserting, into the tubular lumen, the tip of a specially modified amperometric integrated electrode (WPI P/N ISO-NOP007). We review our in vivo experience with this electrode, emphasizing optimal practice to ensure appropriate calibration, stability, and selectivity for in vivo use. The electrode is highly selective for NO, and, despite fragility, with appropriate precautions, it can provide reproducible and highly sensitive NO measurements in the 40-1000 nM range. Full article
(This article belongs to the Special Issue Nitric Oxide Sensors and Their Applications in Biomedical Research)
Show Figures

Figure 1

317 KiB  
Article
The Electrochemical Detremination of Nitric Oxide in Seawater Media with Microelectrodes
by Zhengbin Zhang, Lei Xing, Liqing Jiang, Yongchen Wang, Chunyan Ren and Wei-Jun Cai
Sensors 2003, 3(8), 304-313; https://doi.org/10.3390/s30800304 - 22 Aug 2003
Cited by 11 | Viewed by 9563
Abstract
The electrochemical determination of nitric oxide in seawater with microelectrodes is reported in this paper. Two electrodes, ISO-NOPMC microsensor and modified platinum microelectrode, are evaluated for their performance in seawater. The peak current is found to be linear with the NO concentration in [...] Read more.
The electrochemical determination of nitric oxide in seawater with microelectrodes is reported in this paper. Two electrodes, ISO-NOPMC microsensor and modified platinum microelectrode, are evaluated for their performance in seawater. The peak current is found to be linear with the NO concentration in the range 1×10-6-1.2×10-5 mol/l for both microelectrodes. The detection limit of ISO-NOPMC microsensor is 1.4×10-8 mol/l. Two methods for calibration of NO sensor, saturated NO solutions and decomposition of S-nitroso-acetyl-DL-penicillamine (SNAP), are discussed and compared. In addition, we examined the performance degradation of these microelectrodes in seawater due to complexation with seawater components. Full article
(This article belongs to the Special Issue Nitric Oxide Sensors and Their Applications in Biomedical Research)
Show Figures

Figure 1

287 KiB  
Article
On the Electrooxidation and Amperometric Detection of NO Gas at the Pt/Nafion® Electrode
by Kuo-Chuan Ho, Wen-Tung Hung and Jin-Cherng Yang
Sensors 2003, 3(8), 290-303; https://doi.org/10.3390/s30800290 - 22 Aug 2003
Cited by 14 | Viewed by 10669
Abstract
The electrochemical oxidation of nitric oxide (NO) gas at the Pt/Nafion® electrode has been studied at a concentration of 500 ppm. The electrooxidation of NO taking place over a wide potential range can be described by a transcendental equation, from which the [...] Read more.
The electrochemical oxidation of nitric oxide (NO) gas at the Pt/Nafion® electrode has been studied at a concentration of 500 ppm. The electrooxidation of NO taking place over a wide potential range can be described by a transcendental equation, from which the half-wave potential of the reaction can be determined. For NO oxidation with appreciable overpotentials but negligible mass-transfer effects, the Tafel kinetics applies. The obtained charge transfer coefficient (a) and the exchange current density (io) are 0.77 and 14 mA/cm2, respectively. An amperometric NO gas sensor based on the Pt/Nafion® electrode has been fabricated and tested over the NO concentration range from 0 to 500 ppm. The Pt/Nafion® electrode was used as an anode at a fixed potential, preferably 1.15 V (vs. Ag/AgCl/sat. KCl), which assures current limitation by diffusion only. The sensitivity of the electrochemical sensor was found to be 1.86 mA/ppm/cm2. The potential interference by other gases, such as nitrogen dioxide (NO2) and carbon monoxide (CO), was also studied in the range 0-500 ppm. Both sensitivity for NO and selectivity of NO over NO2/CO show significant enhancement upon using a cyclic voltammetric (CV) activation, or cleaning procedure. Full article
(This article belongs to the Special Issue Nitric Oxide Sensors and Their Applications in Biomedical Research)
Show Figures

Figure 1

207 KiB  
Article
The NO2 sensing ITO thin films prepared by ultrasonic spray pyrolysis
by Zheng Jiao, Minghong Wu, Zheng Qin, Minghua Lu and Jianzhong Gu
Sensors 2003, 3(8), 285-289; https://doi.org/10.3390/s30800285 - 22 Aug 2003
Cited by 17 | Viewed by 9546
Abstract
In this paper ITO thin films were deposited on alumina substrates by ultrasonic spray pyrolysis. The NO2 sensing properties of ITO thin films were investigated. The results show ITO thin films have good sensitivity to nitrogen dioxide. Full article
(This article belongs to the Special Issue Nitric Oxide Sensors and Their Applications in Biomedical Research)
Show Figures

Figure 1

Review

Jump to: Research

155 KiB  
Review
Measurement of Nitric Oxide Production in Biological Systems by Using Griess Reaction Assay
by Jie Sun, Xueji Zhang, Mark Broderick and Harry Fein
Sensors 2003, 3(8), 276-284; https://doi.org/10.3390/s30800276 - 22 Aug 2003
Cited by 508 | Viewed by 43146
Abstract
A review of using Griess Reaction method to determine nitric oxide production in biological systems. Full article
(This article belongs to the Special Issue Nitric Oxide Sensors and Their Applications in Biomedical Research)
Back to TopTop