Next Article in Journal
Probing the Effect of Linear and Crosslinked POE-g-GMA on the Properties of Asphalt
Next Article in Special Issue
Higher Risk of Reoperation after Total Knee Arthroplasty in Young and Elderly Patients
Previous Article in Journal
Evaluation of the Microstructure and Mechanical Properties of the Butt-Welded Joints of Spiral Pipes Made of L485ME (X70) Steel
Previous Article in Special Issue
SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Systematic Review

Evaluating the Biomechanical Integrity of Various Constructs Utilized for First Metatarsophalangeal Joint Arthrodesis: A Systematic Review

1
Feinberg School of Medicine, Northwestern University, Chicago, IL 60208, USA
2
College of Medicine, Northeast Ohio Medical University, Rootstown, OH 44272, USA
3
Campbell University School of Osteopathic Medicine, Lillington, NC 27546, USA
4
Department of Orthopedics and Rehabilitation, University of Iowa, Iowa City, IA 52242, USA
5
Department of Orthopaedic Surgery, Duke University, Durham, NC 27708, USA
6
Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI 48109, USA
*
Author to whom correspondence should be addressed.
Materials 2023, 16(19), 6562; https://doi.org/10.3390/ma16196562
Submission received: 30 August 2023 / Revised: 27 September 2023 / Accepted: 3 October 2023 / Published: 5 October 2023

Abstract

The first metatarsophalangeal (MTP) joint is a frequently loaded joint, handling loads up to 90% of bodyweight. First MTP arthrodesis is a frequently performed procedure designed to improve pain in patients with degenerative MTP joint disease. There are a wide variety of fixation constructs for this procedure without consensus on the most effective method. The purpose of this study was to compare the biomechanical integrity of various constructs utilized for first MTP arthrodesis. A systematic review of the literature was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. PubMed, CINAHL, MEDLINE, and Web of Science databases were searched from inception to 18 June 2023. Articles discussing the biomechanics of first MTP arthrodesis constructs were included. A total of 168 articles were retrieved. A total of 20 articles involving 446 cadaveric and synthetic bone constructs were included in the final review. Of the six articles comparing dorsal plating with compression screws to crossed interfragmentary screws, five found that dorsal plating had significantly higher stiffness. All three studies assessing shape-memory staples found them to be significantly less stable than crossed screws or dorsal plates alone. Both studies evaluating fully threaded screws found them to be stronger than crossed cancellous screws. Wedge resections have been shown to be 10 times stronger than standard planar or conical excision. Dorsal plating with compression screws is the gold standard for MTP arthrodesis. However, more research into newer methods such as fully threaded screws and wedge resections with an increased focus on translation to clinical outcomes is needed.
Keywords: MTP arthrodesis; biomechanics; hallux valgus; dorsal plate; interfragmentary screws MTP arthrodesis; biomechanics; hallux valgus; dorsal plate; interfragmentary screws

Share and Cite

MDPI and ACS Style

Balu, A.R.; Baumann, A.N.; Tsang, T.; Talaski, G.M.; Anastasio, A.T.; Walley, K.C.; Adams, S.B. Evaluating the Biomechanical Integrity of Various Constructs Utilized for First Metatarsophalangeal Joint Arthrodesis: A Systematic Review. Materials 2023, 16, 6562. https://doi.org/10.3390/ma16196562

AMA Style

Balu AR, Baumann AN, Tsang T, Talaski GM, Anastasio AT, Walley KC, Adams SB. Evaluating the Biomechanical Integrity of Various Constructs Utilized for First Metatarsophalangeal Joint Arthrodesis: A Systematic Review. Materials. 2023; 16(19):6562. https://doi.org/10.3390/ma16196562

Chicago/Turabian Style

Balu, Abhinav R., Anthony N. Baumann, Terence Tsang, Grayson M. Talaski, Albert T. Anastasio, Kempland C. Walley, and Samuel B. Adams. 2023. "Evaluating the Biomechanical Integrity of Various Constructs Utilized for First Metatarsophalangeal Joint Arthrodesis: A Systematic Review" Materials 16, no. 19: 6562. https://doi.org/10.3390/ma16196562

APA Style

Balu, A. R., Baumann, A. N., Tsang, T., Talaski, G. M., Anastasio, A. T., Walley, K. C., & Adams, S. B. (2023). Evaluating the Biomechanical Integrity of Various Constructs Utilized for First Metatarsophalangeal Joint Arthrodesis: A Systematic Review. Materials, 16(19), 6562. https://doi.org/10.3390/ma16196562

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop