Next Article in Journal
Probiotics in the Management of Vulvovaginal Candidosis
Previous Article in Journal
Effectiveness of Interspinous Process Devices in Managing Adjacent Segment Degeneration Following Lumbar Spinal Fusion: A Systematic Review and Meta-Analysis
Previous Article in Special Issue
One Year Follow-Up of a 4-Year-Old Caucasian Girl Diagnosed with Stage IV Grade C Localized Periodontitis
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Analysis of 8.5 mm Long Dental Implants Provided with Splinted or Solitary Implant Restorations: A 15-Year Prospective Study

1
Department of Oral and Maxillofacial Surgery, University Medical Center Groningen and University of Groningen, 9700 RB Groningen, The Netherlands
2
Department of Periodontology, Center for Dentistry and Oral Hygiene, University Medical Center Groningen and University of Groningen, 9713 GZ Groningen, The Netherlands
3
Department of Restorative Dentistry, Center for Dentistry and Oral Hygiene, University Medical Center Groningen and University of Groningen, 9713 GZ Groningen, The Netherlands
*
Author to whom correspondence should be addressed.
J. Clin. Med. 2024, 13(17), 5162; https://doi.org/10.3390/jcm13175162
Submission received: 24 July 2024 / Revised: 28 August 2024 / Accepted: 29 August 2024 / Published: 30 August 2024
(This article belongs to the Special Issue Innovative Research in Periodontology and Implantology)

Abstract

Background/Objectives: The long-term effects of implant properties, such as implant length, platform switch, and crown splinting, on peri-implant health require more investigation. Therefore, the aim was to assess the long-term peri-implant health and patient satisfaction in a patient cohort, obtained from two prospective randomized controlled trials, who received 8.5 mm long dental implants, with either splinted or solitary suprastructures and with or without a platform switch, over a period of 15 years. Methods: One hundred and twenty-two patients received either one or two 8.5 mm long dental implants (223 dental implants) with and without platform switch, restored with either a solitary (n = 89) or a splinted (n = 134) restoration in the posterior region. Clinical and radiographical parameters and patient satisfaction were prospectively recorded at 1 month, and 1, 5, and 15 years after the placement of the restoration. Patient satisfaction was recorded with a self-administered questionnaire using a 5-point scale and a visual analog scale (0–10). Results: Eighty-one patients with one hundred and fifty-four implants were assessed after a 15-year follow-up. The clinical parameters were low and comparable between the implant types (OsseoTite XP Certain, OsseoTite XP Certain Prevail, NanoTite XP Certain, NanoTite XP Certain Prevail, PalmBeach Gardens, FL, USA) over time. The implants that incorporated a platform switch showed significantly less bone loss than the implants without a platform switch (−0.37 mm, 95% CI −0.69 to −0.05 mm, p = 0.024 and β = −0.47, 95% CI −0.80 to −0.14, p = 0.006). The implants with splinted restorations experienced more bone loss over time compared to the implants with solitary restorations (0.39 mm, 95% CI 0.15–0.63, p = 0.002). Patient satisfaction was high after 15 years. Conclusions: All the tested dental implants with 8.5 mm length provide satisfactory 15-year results with regard to the clinical and radiographical parameters as well as patient satisfaction. The platform-matched implants were associated with more bone loss compared to the platform-switched implants, and the implants with splinted crowns portrayed more bone loss than the solitary implant crowns.
Keywords: dental implants; peri-implant health; peri-implantitis; platform switch; splinted restorations dental implants; peri-implant health; peri-implantitis; platform switch; splinted restorations

Share and Cite

MDPI and ACS Style

Hakkers, J.; Telleman, G.; de Waal, Y.C.M.; Gareb, B.; Vissink, A.; Raghoebar, G.M.; Meijer, H.J.A. Analysis of 8.5 mm Long Dental Implants Provided with Splinted or Solitary Implant Restorations: A 15-Year Prospective Study. J. Clin. Med. 2024, 13, 5162. https://doi.org/10.3390/jcm13175162

AMA Style

Hakkers J, Telleman G, de Waal YCM, Gareb B, Vissink A, Raghoebar GM, Meijer HJA. Analysis of 8.5 mm Long Dental Implants Provided with Splinted or Solitary Implant Restorations: A 15-Year Prospective Study. Journal of Clinical Medicine. 2024; 13(17):5162. https://doi.org/10.3390/jcm13175162

Chicago/Turabian Style

Hakkers, Jarno, Gerdien Telleman, Yvonne C. M. de Waal, Barzi Gareb, Arjan Vissink, Gerry M. Raghoebar, and Henny J. A. Meijer. 2024. "Analysis of 8.5 mm Long Dental Implants Provided with Splinted or Solitary Implant Restorations: A 15-Year Prospective Study" Journal of Clinical Medicine 13, no. 17: 5162. https://doi.org/10.3390/jcm13175162

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop