Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (6)

Search Parameters:
Keywords = pure membrane electrical resistance

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 4178 KB  
Article
Improving Anti-Corrosion and Conductivity of NiTi Alloy Bipolar Plate Used for PEMFCs via Nb Alloying
by Ziyang Niu, Yingping Li, Yuanyuan Li, Xiaofen Wang, Yumin Pan, Zhuo He, Guohong Zhang, Zhen Wang and Qiongyu Zhou
Molecules 2025, 30(17), 3658; https://doi.org/10.3390/molecules30173658 - 8 Sep 2025
Cited by 1 | Viewed by 747
Abstract
NiTi alloy has emerged as a promising bipolar plate (BP) material for proton exchange membrane fuel cells (PEMFCs), combining Ti-like corrosion resistance with Ni-like electrical conductivity through its intermetallic characteristics. However, its performance faces greater challenges under aggressive operating conditions (70 °C, F [...] Read more.
NiTi alloy has emerged as a promising bipolar plate (BP) material for proton exchange membrane fuel cells (PEMFCs), combining Ti-like corrosion resistance with Ni-like electrical conductivity through its intermetallic characteristics. However, its performance faces greater challenges under aggressive operating conditions (70 °C, F-containing acidic solution with air bubbling). This study demonstrates that Nb alloying effectively enhances NiTi while preserving its balanced properties. The developed NiTiNb alloy exhibits improved performance with 26% lower corrosion current density (ic) and 29% reduced interfacial contact resistance (ICR) compared to conventional NiTi, effectively overcoming the conventional corrosion–conductivity trade-off in metallic BPs. The alloy also shows superior electrochemical stability and microhardness relative to pure Ti and Ni. These enhancements stem from a unique dual-phase microstructure comprising a NiTi (B2) matrix with continuous β-Nb grain boundary networks. During operation, this structure enables in situ formation of protective TiO2-Nb2O5 films while maintaining conductive Nb/Nb2O5 pathways and metallic Ni domains. The findings establish Nb alloying as a viable optimization strategy for NiTi-based BP substrate in demanding PEMFC applications. Full article
(This article belongs to the Special Issue Electroanalysis of Biochemistry and Material Chemistry—2nd Edition)
Show Figures

Figure 1

18 pages, 4578 KB  
Article
Mitigating Membrane Fouling in Abattoir Wastewater Treatment: Integration of Pretreatment Step with Zwitterion Modified Graphene Oxide–Polyethersulfone Composite Membranes
by Meladi L. Motloutsi, Funeka Matebese, Mxolisi M. Motsa, Muthumuni Managa and Richard M. Moutloali
Membranes 2024, 14(11), 227; https://doi.org/10.3390/membranes14110227 - 30 Oct 2024
Cited by 4 | Viewed by 2100
Abstract
Composite polyethersulfone (PES) membranes containing N-aminoethyl piperazine propane sulfonate (AEPPS)-modified graphene oxide (GO) were integrated with either of the two pretreatment processes (activated carbon (AC) adsorption or polyelectrolyte coagulation) to assess their effectiveness in mitigating membrane fouling during the treatment of abattoir wastewater. [...] Read more.
Composite polyethersulfone (PES) membranes containing N-aminoethyl piperazine propane sulfonate (AEPPS)-modified graphene oxide (GO) were integrated with either of the two pretreatment processes (activated carbon (AC) adsorption or polyelectrolyte coagulation) to assess their effectiveness in mitigating membrane fouling during the treatment of abattoir wastewater. The AEPPS@GO-modified membranes, as compared to the pristine PES membranes, showed improved hydrophilicity, with water uptake increasing from 72 to 118%, surface porosity increasing from 2.34 to 27%, and pure water flux (PWF) increasing from 235 to 673 L.m−2h−1. The modified membranes presented improved antifouling properties, with the flux recovery ratio (FRR) increasing from 59.5 to 93.3%. This study compared the effectiveness of the two pretreatment processes, AC, coagulation, and the integrated system (coagulation/AC-UF membrane), in the removal of natural organic matter (NOM) and improvement of abattoir wastewater’s pH, electrical conductivity, TDS, and turbidity. The integrated systems produced improved water quality in terms of pH, EC, TDS, turbidity, and organic content. The fluorescence excitation–emission matrix (FEEM) analysis exhibited almost no fluorescence peak post-treatment following organic loading removal. The quality of the water met the South African non-potable water reuse standards. The sole membrane treatment systems exhibited good fouling resistance without the pretreatment systems; however, integrating these systems can offer extended longer filtration periods, thereby assisting in cost aspects of the abattoir wastewater treatment system. Full article
(This article belongs to the Section Membrane Applications for Water Treatment)
Show Figures

Figure 1

15 pages, 5839 KB  
Article
Electrochemical Behavior of Tantalum Nitride Protective Layers for PEMFC Application
by Aurélie Achille, Fabrice Mauvy, Sebastien Fourcade, Dominique Michau, Marjorie Cavarroc and Angéline Poulon-Quintin
Energies 2024, 17(20), 5099; https://doi.org/10.3390/en17205099 - 14 Oct 2024
Cited by 5 | Viewed by 1690
Abstract
Proton Exchange Membrane Fuel Cells (PEMFCs) are promising technology to convert chemical energy from dihydrogen in electrical energy. HT-PEMFCs are working at high temperatures (above 120 °C) and with doped orthophosphoric acid H3PO4 PBI membranes. In such devices, bipolar metallic [...] Read more.
Proton Exchange Membrane Fuel Cells (PEMFCs) are promising technology to convert chemical energy from dihydrogen in electrical energy. HT-PEMFCs are working at high temperatures (above 120 °C) and with doped orthophosphoric acid H3PO4 PBI membranes. In such devices, bipolar metallic plates are used to provide reactive gas inside the fuel cell and collect the electrical current. The metallic elements used as bipolar plates, end plates, and interconnectors in acid electrolyte and gaseous fuel cells are severely damaged by a combination of oxidation (due in particular to the use of oxygen, whether pure or contained in the air) and corrosion (due in particular to acid effluents from the electrolyte). This degradation rapidly leads to the loss of the electrical conductivity of the metallic elements and today requires the use of very specific alloys, possibly coated with pure gold. The solution investigated in the present study is the use of a protective coating based on single-phase nitrides obtained by reactive magnetron sputtering or reactive HiPIMS (High-Power Impulse Magnetron Sputtering). The influence of the microstructure on the physical–chemical properties was studied. The electrochemical properties were quantified following two approaches. First, the corrosion current of the developed coatings was measured at room temperature and at higher temperatures using the Linear Sweep Voltammetry (LSV) technique. Then, Electrochemical Impedance Spectroscopy (EIS) measurements were performed to better identify and evaluate their corrosion-resistance performances. Full article
(This article belongs to the Section A5: Hydrogen Energy)
Show Figures

Figure 1

15 pages, 7165 KB  
Article
Research on Measuring Pure Membrane Electrical Resistance under the Effects of Salinity Gradients and Diffusion Boundary Layer and Double Layer Resistances
by Yang Zhao and Liang Duan
Membranes 2022, 12(8), 816; https://doi.org/10.3390/membranes12080816 - 22 Aug 2022
Cited by 9 | Viewed by 3232
Abstract
Forward osmosis membranes are an emerging technology with great potential applicability in energy-efficient wastewater treatments and the differentiation between two solutions. Such solutions often differ in their concentrations or compositions. In this study, the membrane electrical resistances of three different membranes, including cation [...] Read more.
Forward osmosis membranes are an emerging technology with great potential applicability in energy-efficient wastewater treatments and the differentiation between two solutions. Such solutions often differ in their concentrations or compositions. In this study, the membrane electrical resistances of three different membranes, including cation or anion-exchange membranes and forward osmosis membranes, were analyzed by Luggin capillary coupled with AC impedance spectroscopy (EIS) so as to obtain the real membrane and ion transfer impedance values near the membrane interface. The results reveal that the membrane impedance obtained by both the DC and AC approaches decreased as the lowest external solution concentration increased. Furthermore, the relationship between the membrane conductivity and the internal salt solution concentration was also investigated. It can be seen that the external ion concentration is directly proportional to the free ion concentration in the membrane, and the free ion concentration in the membrane is closely related to the membrane electrical resistance. Full article
Show Figures

Figure 1

12 pages, 2803 KB  
Article
Experimental Study of Power Generation and COD Removal Efficiency by Air Cathode Microbial Fuel Cell Using Shewanella baltica 20
by Subhashis Das and Rajnish Kaur Calay
Energies 2022, 15(11), 4152; https://doi.org/10.3390/en15114152 - 5 Jun 2022
Cited by 25 | Viewed by 4436
Abstract
Microbial fuel cells (MFCs) are a kind of bioreactor for generating electricity, facilitated by exoelectrogens while treating wastewater. The present article focuses on the performance of an air cathode plexiglass MFC in terms of chemical oxygen demand (COD) removal efficiency and power output [...] Read more.
Microbial fuel cells (MFCs) are a kind of bioreactor for generating electricity, facilitated by exoelectrogens while treating wastewater. The present article focuses on the performance of an air cathode plexiglass MFC in terms of chemical oxygen demand (COD) removal efficiency and power output by performing two sets of experiments. The proton exchange membrane and electrode materials were Nafion 117 and carbon felts, whereas, for stable biofilm formation on the anode surface, a pure culture of Shewanella baltica 20 was used. Firstly, sterile Luria-Bertani (LB) media containing lactate, ranging from 20 to 100 mM, was continuously fed to an MFC, and a maximum power density of 55 mW/m2 was observed. Similarly, artificial wastewater with COD ranging from 3250 mg/L to 10,272 mg/L was supplied to the MFC in the second set of experiments. In this case, the maximum power density and COD removal efficiency were 12 mW/m2 and 57%, respectively. In both cases, the hydraulic retention time (HRT) was 1.5 h. It was found that electricity generation depends on the characteristics of the wastewater. These initial findings confirm that the design aspects of an MFC, i.e., surface area to volume ratio, and external resistance with respect to the quality of influent need to be optimised to improve the MFC’s performance. Full article
Show Figures

Figure 1

12 pages, 2342 KB  
Article
Design and Fabrication of a Microfluidic Viscometer Based on Electrofluidic Circuits
by Bo-Bi Tzeng and Yung-Shin Sun
Micromachines 2018, 9(8), 375; https://doi.org/10.3390/mi9080375 - 27 Jul 2018
Cited by 10 | Viewed by 5467
Abstract
This paper reports a microfluidic viscometer based on electrofluidic circuits for measuring viscosities of liquid samples. The developed micro-device consists of a polydimethylsiloxane (PDMS) layer for electrofluidic circuits, a thin PDMS membrane, another PDMS layer for sample pretreatment, and a glass substrate. As [...] Read more.
This paper reports a microfluidic viscometer based on electrofluidic circuits for measuring viscosities of liquid samples. The developed micro-device consists of a polydimethylsiloxane (PDMS) layer for electrofluidic circuits, a thin PDMS membrane, another PDMS layer for sample pretreatment, and a glass substrate. As the sample flows inside the microfluidic channel, its viscosity causes flow resistance and a pressure drop along this channel. This pressure drop, in turn, generates a hydraulic pressure which deforms the PDMS membrane, causing changes in the cross-sectional area and the electrical resistance of the electrofluidic resistor. This small resistance change is then measured via the electrofluidic Wheatstone bridge to relate the measured voltage difference to the fluidic viscosity. The performance of this viscometer was first tested by flowing nitrogen gas with controllable pressures into the device. The relationship between measured voltage difference and input gas pressure was analyzed to be linear in the pressure range of 0–15 psi. Another test using pure water indicated good linearity between measured voltage difference and flow rate in the rate range of 20–100 μL/min. Viscosities of glycerol/water solutions with volume/volume (v/v) concentrations ranging from 0 to 30% were measured, and these values were close to those obtained using commercially available viscometers. In addition, the sample-pretreatment layer can be used to mix and/or dilute liquid samples to desired concentrations. Therefore, this microfluidic device has potential for measurements of fluidic viscosity in a fast, accurate, and high-throughput manner. Full article
(This article belongs to the Special Issue Microfluidic Sensors)
Show Figures

Figure 1

Back to TopTop