Article

Evaluating the Water Quality of the Keddara Dam (Algeria) Using Water Quality Indices

by
Tosin Sarah Fashagba
1,
Madani Bessedik
2,3,
Nadia Badr ElSayed
4,
Chérifa Abdelbaki
1,2,3 and
Navneet Kumar
5,6,*
1
Pan African University-Institute of Water and Energy Science, Including Climate Change (PAUWES), Pôle Chetouane, P.O. Box 119, Tlemcen 13000, Algeria
2
Department of Hydraulics, Faculty of Technology, University of Tlemcen, P.B. 230, Tlemcen 13000, Algeria
3
Laboratoire EOLE, University of Tlemcen, P.B. 230, Tlemcen 13000, Algeria
4
Environmental Sciences Department, Faculty of Science, Alexandria University, Alexandria 21511, Egypt
5
Department of Ecology and Natural Resources Management, Center for Development Research (ZEF), University of Bonn, Genscherallee 3, 53113 Bonn, Germany
6
Global Mountain Safeguard Research (GLOMOS), United Nations University—Institute for Environment and Human Security (UNU-EHS), UN Campus, Platz der Vereinten Nationen 1, 53113 Bonn, Germany
*
Author to whom correspondence should be addressed.
Water 2024, 16(9), 1291; https://doi.org/10.3390/w16091291
Submission received: 4 March 2024 / Revised: 26 April 2024 / Accepted: 29 April 2024 / Published: 1 May 2024
(This article belongs to the Special Issue Water Quality Assessment of River Basins)

Abstract

:
Dams are regarded as crucial pieces of structure that store water for irrigation and municipal uses. Given their vital role, the dam’s water quality assessment is considered to be an important criterion and requires constant monitoring. In this research, we attempted to use two water quality indices (WQIs) methods to assess the water quality of the Keddara Dam, which is located on the Boudouaou River, Algeria, using eleven water quality parameters (temperature, pH, conductivity, turbidity, total suspended solids (TSS), full alkalimetric title (TAC), hydrometric title (TH), nitrite ions (NO2−), nitrate ions (NO3−), ammonium ions (NH4+), and phosphate ions (PO43−)) for data recorded from 29 December 2018 to 3 June 2021. Application of The Canadian Council of Ministers of the Environment (CCME) WQIs and the Weighted Arithmetic Method (WAM) indicated that the Keddara Dam’s water quality parameters were within the WHO’s permissible level, except for the conductivity and turbidity values. The results of the CCME WQI ranged from acceptable (81.92) to excellent (95.08) quality, whereas the WAM WQI ranged from 9.52 to 17.77, indicating excellent quality. This demonstrates that the Keddara Dam is appropriate for agriculture and municipal use. The water quality indices (WQIs) methods are recommended as valuable tools that allow both the public and decision-makers to comprehend and manage the water quality of any aquatic environment by providing flexibility in choosing variables.

1. Introduction

Surface water pollution has become a serious environmental issue on a global scale that needs to be continuously assessed and monitored at all scales to ensure the sustainability of ecosystems [1]. Surface water quality monitoring requires a thorough process that involves numerous chemical studies of water [2]. Throughout the world, river systems are significantly impacted by pollution. The primary reason for this is the extremely rapid urbanisation that forces the flow of treated and untreated wastewater into river systems. Harmful chemical pesticides, insecticides, fertilisers, and herbicides are used more frequently as a result of the rapid expansion of industrial facilities along rivers and the increase in agriculture [3]. Water resources, particularly surface water, have gradually declined as a result of this and continuously affect human health, as diseases are largely spread through contaminated water [4]. Every year, water-borne illnesses claim the lives of roughly 1.8 million individuals in developing nations, most of whom are children [4]. Consequently, to protect water resources against harmful contaminants, it is crucial to monitor changes in water quality.
Due to its limited water resources, with annual rainfall of less than 200 mm, Algeria is recognised as an arid and semi-arid region. This results in notable regional and temporal fluctuations in water availability [5]. Approximately 87% of Algeria, covering 2.4 million km2, is composed of desert which sees little to no rainfall, ranking it among one of the driest countries in the world [6]. Over the past two decades, Algeria’s water resources have undergone severe stress due to factors such as urbanisation, climate change, and inadequate water usage planning [5] that, in turn, affect the availability and quality of water. Climate change in Algeria has disrupted weather patterns such as precipitation and the water cycle, which has affected groundwater recharge and soil moisture [5]. In addition, the demand for water for various reasons is rising as a result of the expanding population [7] and increased usage of land for agriculture [8]. Furthermore, numerous types of pollution are degrading the condition of rivers in Algeria. The availability of water resources has decreased and they are difficult to use, and are frequently in contact with large volumes of effluent [9]. There have been concerns about diverse pollution sources causing water quality degradation in some dam lakes over the past few decades [10,11,12,13,14].
To assess the water quality and chemistry in aquatic environments, a variety of methods have been used. Water quality indices (WQIs) are the most efficient way to communicate to the public, decision-makers, and user communities to detect threats to many different uses of water, including habitat for aquatic life, irrigation water for agricultural areas, recreation, aesthetics, and drinking water supplies [9,15]. The WQI model, a mathematical method, is frequently used to evaluate aquatic ecosystem quality from various sources using a set of chosen water quality criteria [16]. The model simplifies a large amount of water quality data into a single composite number [16]. The WQI model is an effective tool that makes it easier to comprehend the overall condition of an aquatic ecosystem based on a single index, in contrast to traditional methods of water quality assessment which involve lengthy lists of parametric water quality values. Understanding this index helps to inform the public and the government about the worldwide condition of the water quality in a certain area [9].
Based on ten indicators that were considered critical for the majority of waterbodies, Horton developed the first WQI model in the 1960s [17]. In 1965, Brown, assisted by the National Sanitation Foundation (NSF), developed the NSF-WQI, a more exacting iteration of Horton’s WQI model [17]. This model was partially incorporated into the Scottish Research Development Department’s method (SRDD). Other specific indices have been developed, such as the SRDD-WQI (1973), Bascaron Index (1979), Dalmatian Index, and House Index (1986) [17]. The British Columbia Ministry for Environment, Lands and Parks created the British Columbia Water Quality Index (BCWQI) in the mid-1990s, which was another significant development. It is used to assess the quality status of numerous waterbodies in the Canadian province of British Columbia [17]. The Canadian Council of Ministers of the Environment Water Quality Index (CCME WQI) was created in 2001 [18]. Recently, many nations and organisations have introduced more than 35 WQI methods to assess surface water quality globally [19]. The lack of a sufficient dataset and the numerous alternatives for choosing different sets of indicators and objective values are the key challenges in assessing the performance of WQIs in surface water bodies around the world [20].
The Keddara Dam is regarded as the region’s backbone and provides water to Algiers for municipal and agricultural purposes. Limited research has been carried out on the water quality of the Keddara Dam water using WQIs methods. Thus, this study was conducted using the Weighted Arithmetic Method Water Quality Index (WAM WQI) and the Canadian Council of Ministers of the Environment Water Quality Index (CCME WQI), to assess the Keddara Dam’s surface water quality for drinking purposes.
The findings of this research will provide valuable and new information to policymakers and managers of water resources, helping them make decisions about water resource management regarding the area under investigation. This methodology is transferable and applicable to any dry or semi-arid region, making it a practical instrument for environmental management and assessments.

2. Materials and Methods

2.1. Study Area

The Keddara Dam is located 6 kilometres (4 miles) northwest of Keddara Town, on the Boudouaou River in Boumerdès Province, Algeria (36°39′03.0″ N 3°24′58.9″ E) (Figure 1). The Keddara Dam is also called the Barrage Keddara. Built between 1982 and 1987, the dam supplies water to Algiers, situated 35 km to the west, for municipal use [21]. With a capacity of 146,500,000 m3 (118,769 acre-ft), the dam’s reservoir can store water collected from drainage via a gallery, the Hamiz Dam, 7.6 km to the west, and by pumping water at a rate of 7 m3/s from the Beni Amrane Dam, 17 km to the east. River Bouira and River Medea are the main sources of the Keddara Dam. The dam is about 100 km east of Algiers. The population density and land use dynamics are rising in the Boumerdès Province. Thus, research in this area will help us to determine if these factors affect water quality.

2.2. Data Collection and Analytical Techniques

This research employed the use of secondary data obtained from the Algiers Water and Sanitation Company (SEAAL). The SEAAL firm adhered to conventional procedures for analysing water and wastewater in all of their analytical methodologies [22]. The sampling period was from 29 December 2018 to 3 June 2021. A total of 338 water samples with 11 water quality parameters for the period of 29 December 2018–3 June 2021 were collected. These were the only data that were accessible. The parameters chosen for this study were based on parameters with sufficient daily measurements. They are Temperature, pH, conductivity, turbidity, total suspended solids (TSS), full alkalimetric title (TAC), hydrometric title (TH), nitrite ions (NO2−), nitrate ions (NO3−), ammonium ions (NH4+) and phosphate ion (PO43−). The data had outliers and missing values, which were considered during the analysis. Days with less than five parameters reported were removed.

2.3. Statistical Analysis of the Water Quality Parameters

Daily time steps are typically used for water quality monitoring in water treatment plants to ensure the system is functioning effectively. This generates time series data for different water quality parameters. Data accuracy is essential for the efficient determination of water quality indices [23,24]. Removing the outliers is crucial to avoid any skewing of the information derived from the raw data. Excel software was used for this analysis.

Detection of Outlier and Normality Testing

According to [24], “An outlying observation (outlier) appears to deviate from other members of the sample in which it occurs and should be identified and removed” [24,25]. To find outliers in this study, the box plot method described by Tukey (1977) was applied [26,27,28]. The interquartile distance (Q3 − Q1), which is equivalent to 1.5 times the box’s height, is typically used to calculate whiskers. In these conditions, a value is considered abnormal if it is more than the interquartile gap either above the third quartile (Q3) or below the first quartile (Q1) [27]. Tukey (1977) [26] asserts that the rule of thumb’s pragmatic value of 1.5 is based on a probabilistic basis. The outliers are calculated based on the following equations:
Minor outlier (Min. Out.) = Q1 − 1.5 × (Q3 − Q1)
Major outlier (Maj. Out.) = Q3 + 1.5 × (Q3 − Q1)
Upon detection, outliers were removed to prevent calculation interference. After removal, the raw water samples were reduced to 309 samples. The datasets were then subjected to normality testing. This study used one graphic method (quantile regression) and two numerical methods (Shapiro–Wilk, Kolmogorov–Smirnov) [29]. The different normality tests were implemented to compare different normality methods and account for the small sample size.
  • The Shapiro–Wilk test: If the p-value is greater than the chosen significance threshold (e.g., 0.05), the data are mostly consistent with a normal distribution, and the null hypothesis is still true. If the p-value is less than the significance level, on the other hand, it means that the data deviate significantly from normality, and the null hypothesis is rejected [29].
  • Kolmogorov–Smirnov: By demonstrating that the sample did not originate from the selected distribution, the Kolmogorov–Smirnov test rejects the null hypothesis if the p-value is less than the set significance threshold, which is often 0.05 or 0.01. The null hypothesis cannot be ruled out if the p-value is greater than the significance level, and we may reasonably conclude that the sample may originate from the given distribution [29].
  • Quantile regression approach: Using the quantile regression method, the graph of normal quantiles is produced. A regression model is created for a subset of the response variable’s limited distribution. The data have a normal distribution if a linear relation can be inferred from this graph. The closer the R2 is to 1, the better the data distribution [29].

2.4. Application of Water Quality Index (WQI)

The WQI is the most effective method for characterising the overall water quality based on several parameters. As previously mentioned, WQI may compress a large amount of data into a single number to communicate the information in a straightforward and accessible manner, making it understandable and accessible to a wide audience. The Keddara Dam’s water quality index was assessed using the selected methodologies: CCME WQI and WAM WQIs. The methodology of [30] was followed in this study to employ the WHO standards as suggestions for irrigation and drinking (Table 1).
These two popular techniques were selected for this study, mainly because of their ease of use and ease of calculation, as well as their excellent track record with several experts who have evaluated the quality of water from various sources all over the world (Table 2).
Table 1. WHO Standard values used for water quality indices [30,31,32,33,34].
Table 1. WHO Standard values used for water quality indices [30,31,32,33,34].
ParametersStandard Value
Temperature26.5
pH8.5
Conductivity1500
Turbidity5
Total soluble solids30
Total hardness50
Full alkalimetric title20
Nitrite ion3
Nitrate ion50
Ammonia<0.5
Phosphate ion0.5

2.4.1. Canadian Council of Ministers of the Environment (CCME) WQI

The British Colombia WQI Model (BCWQI) served as the foundation for creating the CCME model in 2001 [35]. Three parameters are included in the CCME-WQI, which offers a measure of the deviation of water quality from water quality guidelines. These parameters are scope, frequency, and amplitude [36]. This model has been used in numerous surface water bodies across the globe.
Table 2. The specialised literature used in this study cites case studies using both methods (CCME-WQI and WAM-WQI).
Table 2. The specialised literature used in this study cites case studies using both methods (CCME-WQI and WAM-WQI).
StudyMethod UsedReference
CountryWater Resource Type
Puebla valley, MexicoGroundwaterCCME-WQI[15]
Reghaia, AlgeriaSurface WaterWAM-WQI[36]
Amman-Zaraq, JordanGround WaterCCME-WQI[37]
Ohaozora, NigeriaGround WaterWAM-WQI[38]
WWTP of Oran City, AlgeriaWastewaterCCME-WQI
WAM-WQI
[39]
i.
The CCME WQI method follows the following steps for parameter selection
The user is free to choose which water quality parameters to utilise. The CCME WQI model only mandates the usage of a minimum of four [35]. The developers advise using the evaluation procedures for expert panels in order to choose model parameters.
ii.
Sub-index calculation
There is no sub-index calculation component in the CCME model. This is a significant flaw in this paradigm relative to the others.
iii.
Parameter Weightings
The final WQI can be calculated without the use of parameter weight values.
iv.
Aggregation
The CCME uses an aggregation function that is different from other models. It is written as follows:
WQI = 100 F 1 2 + F 2 2 + F 3 2 1.732
where
F1 is referred to as the “scope”, This is the portion of all parameters that fall short of the desired outcome.
It is expressed as follows:
F 1   = Number   of   failed   parameters Total   number   of   parameters × 100
F2 is referred to as the “frequency”. This fraction of individual test values that do not match the objective values is known as the “frequency” (failed tests).
It is expressed as follows:
F 2   = Number   of   failed   tests Total   number   of   tests × 100
F3: This is calculated in three steps.
  • Calculation of excursion: The number of times an individual concentration exceeds (or falls short of, if the target is at its lowest) the objective is known as the excursion.
The excursion for a test value that is below the objective value is computed as follows:
excursion i   =   Failed   test   value i Objective j 1
On the other hand, the excursion value is determined as follows if the test value is greater than the objective value:
excursion i   =   Objective j Failed   test   value i 1
2.
Calculation of the Normalised Sum of Excursion (nse).
The total amount that each test deviates from compliance is known as the normalised sum of excursions. The computation involves adding up all of the test deviations from the goals and dividing the result by the total number of tests (including goal- and non-goal-achieving tests).
nse   =   i = 1 n excursion i Total   of   number   of   test 1
3.
Calculation of F3
An asymptotic function is used to calculate F3, scaling the normalised total of the deviations from targets to produce a range from 0 to 100.
F 3   = nse 0.01 nse + 0.01
4.
WQI evaluation
The CCME model proposed five water quality classes, as shown in Table 3.

2.4.2. Weighted Arithmetic Method (WAM)

This approach, which is popular and straightforward, combines data for many water quality criteria into an equation that evaluates the quality of the water and gives decision-makers and interested individuals a single, easily comprehensible statistic. It achieves this by calculating the unit weight and quality rating scale for each water quality parameter. Furthermore, it requires fewer parameters than all the water quality characteristics for a specific purpose to characterise surface and groundwater sources’ quality that is sufficient for human consumption [39]. To categorise water quality according to the level of purity, the most measurable parameters were used [40].
The weighted arithmetic method’s computation is as follows:
WQI = ∑QiWi/∑Wi
Each water quality parameter’s unit weight (Wi) is determined using the following formula:
Wi = K/Si
where K stands for the proportionality constant and can also be found using the following equation:
K = 1 1 S i
For every parameter, the quality rating scale (Qi) is computed using the following expression:
Qi = 100 × [(Vi − Vo)/Si − Vo)]
where for every parameter, the quality rating scale (Qi) is computed using the following expression:
Vi: the concentration of the ith parameter of the analysed water.
However, the pH = 7.0 and DO = 14.6 mg/L, Vo = 0, which is the ideal value of this parameter in pure water.
Si represents the recommended standard value of the ith parameter.
The weighted arithmetic water quality index method scale [36] is shown in Table 4.

3. Results and Discussion

3.1. Descriptive Characteristics of the Keddara Dam

Table 5 displays the descriptive characteristics of the water quality parameters in the chosen the Keddara Dam over the monitoring period from 29 December 2018 to 3 June 2021 based on daily measurements.
The pH is a measurement of how acidic/basic water is. This is an important water quality parameter that determines the solubility and biological availability of different chemical constituents in water. The pH values of the dam water during the study period ranged from 7.5 to 8.32, indicating that the water was within an alkaline range. The values are within the permissible ranges (6.0 and 9.0) described in the WHO guidelines. According to the research carried out by [41], algae use CO2 in their photosynthetic activity, leading to an increase in pH values due to a shift in the forms of alkalinity present from bicarbonate to carbonate [42].
Turbidity is a crucial factor in drinking water, as it can affect consumers’ acceptability of water and its utility in some industries. In addition, difficulties in the treatability of water may be encountered in some water treatment plants [43]. The turbidity readings for the Keddara Dam’s surface water ranged from 1.3 NTU to 23.70 NTU, exceeding the threshold permitted by the WHO.
The salinity of water can be identified based on electrical conductivity (EC) or the total dissolved solids (TDS). It is an expression of the ability of water to carry an electric current and is directly related to major ions and the amount of TDS. Moreover, it is important as it impacts the taste and user acceptance of the water as potable [44]. High conductivity can originate from human activity, like sewage and industrial effluent, or it can occur naturally as a result of the weathering of some sedimentary rocks [44]. The Keddara Dam’s water has conductivity values ranging from 1015 μS/cm to 1523 μS/cm, slightly exceeding the recommended levels set by the WHO (Table 5).
The hardness of water is indicative of a large concentration of dissolved minerals leading to an increase in conductivity. It is a crucial indicator of water quality that determines whether it is suitable for use in agriculture, industry, and residential settings or not. For area under investigation, the WHO criterion of 50 F0 was met by the dam water, as the TH ranged from 29 F0 to 50.60 F0. The water’s overall alkalinity is influenced by these ions. In addition to this, the geology of the region the river passes through determines the hard water level. The mean TAC for dam water ranged from 15.60 F0 to 20.80 F0, within the WHO standard limit.
NH4+, NO3, NO2 and PO43− totally referred to as essential nutrients for algal growth. They recorded low concentrations in dam water and none of them exceeded the standard limit for WHO standards (Table 5). The low mean values of nutrients in the Keddara Dam’s water indicated less contamination from the catchment area.

3.2. Outlier Detection Normality Testing

The distribution of the raw data of water from the Keddara Dam (before outliers were removed) for water quality parameters is represented in Figure 2.
After the outliers were removed, normality tests were performed (Table 6). The box plots show that the distribution of the measured values is asymmetric, except for TSS. For temperature, EC, turbidity, NO2, NH4+, and PO43−, the distribution spreads towards the large values. On the other hand, for pH, TH, TAC and NO3 values, the distribution spreads towards small values. This means that for all parameters, the data are not normally distributed, except for TSS. In this context, removing outliers proves to be an effective data processing operation to determine significant WQIs.
Using Shapiro–Wilk test analysis, the p-value of all parameters except TSS, TH, TAC, and NO3 was found to be statistically significant at level (0.05) (Table 6). This means that data is not normally distributed. This might be because the Shapiro–Wilk test is used to analyse the normality of small data sizes [33]. On the other hand, the Kolmogorov–Smirnov test of the raw water showed that all parameters were normally distributed (>0.05) except PO43−, NH4+, and EC. In contrast to the Shapiro–Wilk test, this test is well suited to a long series of data [33]. Aside from NO2, NH4+, and PO43− values, the quantile regression approach showed that all other parameters represented a good linear relationship with an R2 that varied from 0.94 to 0.98.

3.3. Assessment of the Keddara Dam’s Surface Water Using Water Quality Indices

The outcomes of the monitoring program at the Keddara Dam involve a complex matrix of physical and chemical factors. Each of these factors alone is not sufficient for a dependable assessment of the quality of the water over time. To overcome these challenges, two water quality indices (WQIs) were applied to summarise many monitored parameters into one simple term (Table 7).
According to the computed WQI values obtained using the CCME, the water quality of the Keddara Dam water was good (81.92) during the study period, except during the COVID-19 lockdowns when the dam’s water turned out to be of “excellent” quality (95.09) (Table 7). The excellent characteristics during this period can be attributed to low human activities. When the other method (WQI WAM) was used, the results showed that the seasonal surface water quality ranged from approximately 9.52 to 17.77 (excellent condition) and complied with WHO standards (Table 7). The excellent conditions for all seasons compared to the CCME WQI can be attributed to the rating scale used by this method. Consequently, according to both methods, the water quality of the Keddara Dam is suitable for irrigation usage and indicated that the Algerian government have set effective regulations to stop the illegal dumping of waste by industrial and municipal activities since the establishment of Law No. 83-03 on 5 February 1983 relating to environmental protection [45]. This, in turn, helped increase the purity of the Keddara Dam water reaching the water treatment plant.
Currently, there is no research evaluating the water quality of the Keddara Dam using the water quality index methods. However, some researchers have evaluated the dam’s water quality using laboratory techniques. The results presented in this paper align with those presented in research carried out by Ghemmit-Doulache and Ouslimani [46], who measured the physicochemical, biological, and heavy metal parameters at three sites at the Keddara Dam using laboratory techniques. They revealed that the sites’ physical qualities met WHO standards, while the chemical quality showed increased hardness. Another study was performed by Guettache et al., [47] to determine the water quality of the Keddara Dam before and after treatment using laboratory analysis. Based on their findings, they highlighted that the maximum and minimum temperature, conductivity, pH, and nitrate were within the Algerian standards, while the turbidity and ammonia values were above the norm.
A comparison between the Keddara Dam WQI and other Algerian case studies is presented in Table 8.
As shown in Table 8, the quality of the water in our case study is different compared to that of the other studies. This can be explained by the fact that the water mobilised by the Keddara Dam is not overly affected by human activities, especially as the Boudouaou catchment area has neither large urban areas nor industrial activity zones upstream of the dam.
It is worth noting that every WQI method used in this study could be readily implemented and serve as a guide for similar projects aiming to assess the performance of any dam or treatment plant.

4. Conclusions and Recommendations

This study will be the first to apply WQI to the Keddara Dam. It allowed us to evaluate the Keddara Dam’s water quality using the CCME WQI and WAM WQI techniques. The dam’s water quality was assessed using the concentrations of 11 physicochemical parameters such as temperature, pH, conductivity, turbidity, total suspended solids (TSS), full alkalimetric title (TAC), hydrometric title (TH), nitrite ions (NO2−), nitrate ions (NO3−), ammonium ions (NH4+), and phosphate ions (PO43−)). The results revealed that all parameters’ concentrations were within the permissible ranges stated in the WHO guidelines, except for turbidity and salinity parameters, for which values exceeding these ranges were recorded. Before establishing the WQI, the measured values were cleansed of outliers and their normal distribution was examined. When using the CCME, the water quality of the Keddara Dam ranged from good to excellent (81.92 to 95.09), while the WAM quality ranged from 9.52 to 17.77 (excellent condition). These results indicated that raw water from this dam is of good quality. Nevertheless, before it can be used for municipal purposes, it still needs to undergo more standard treatment (pre-treatment, clarity, and disinfection).
This study’s applied methodology may be relevant to areas with similar characteristics in Algeria and elsewhere. This will help decision-makers manage water resources. In prospective, other analyses such as heavy metals and bacteriological analysis are necessary to develop a control approach to limit any negative impacts of the dam’s water. Besides, it is advisable to construct an artificial intelligence model for future analysis of temporal and spatial changes, as well as predictions of water quality in the context of sustainable development and preservation of water resources.

Author Contributions

Conceptualisation, T.S.F., M.B., N.B.E., C.A. and N.K.; methodology, M.B., N.B.E., C.A. and N.K.; software, T.S.F. and M.B.; validation, M.B., N.B.E., C.A. and N.K.; formal analysis, M.B., N.B.E. and N.K.; investigation, M.B. and N.B.E.; resources, N.B.E., C.A. and N.K.; data curation, T.S.F. and C.A.; writing—original draft preparation, T.S.F., M.B. and N.B.E.; writing—review and editing, M.B., N.B.E., C.A. and N.K.; visualisation, M.B., N.B.E., C.A. and N.K.; supervision, M.B., N.B.E. and C.A.; project administration, M.B., N.B.E., C.A. and N.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

Data is contained within the article.

Acknowledgments

The authors would like to express their sincere gratitude to the dedicated team at the Water and Sanitation Society (SEAAL Algiers) for generously providing invaluable data for this study.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Tay, C.K. Integrating water quality indices and multivariate statistical techniques for water pollution assessment of the Volta Lake, Ghana. Sustain. Water Resour. Manag. 2021, 7, 71. [Google Scholar] [CrossRef]
  2. Trach, R.; Trach, Y.; Kiersnowska, A.; Markiewicz, A.; Lendo-Siwicka, M.; Rusakov, K. A study of assessment and prediction of water quality index using fuzzy logic and ANN models. Sustainability 2022, 14, 5656. [Google Scholar] [CrossRef]
  3. Lazizi, A.; Laifa, A. Assessment of the Surface Water Quality: A Case of Wadi El-Kébir West Watershed, Skikda, North-East Algeria. Nat. Environ. Pollut. Technol. 2020, 19, 1977–1985. [Google Scholar] [CrossRef]
  4. Ahmed, I.; Summers, J.K. (Eds.) Promising Techniques for Wastewater Treatment and Water Quality Assessment; BoD–Books on Demand: Schleswig-Holstein, Germany, 2021. [Google Scholar]
  5. Nadir, M.; Boualem, R. Study of Beni Haroun dam pollution (Algeria). Desalination Water Treat. 2016, 57, 2766–2774. [Google Scholar] [CrossRef]
  6. Hamlat, A.; Guidoum, A.; Koulala, I. Status and trends of water quality in the Tafna catchment: A comparative study using water quality indices. J. Water Reuse Desalination 2017, 7, 228–245. [Google Scholar] [CrossRef]
  7. Sadigov, R. Rapid growth of the world population and its socioeconomic results. Sci. World J. 2022, 2022, 8110229. [Google Scholar] [CrossRef] [PubMed]
  8. Djelita, B.; Bouzid-Lagha, S.; Nehar, K.C. Spatial and temporal patterns of the water quality in the Hammam Boughrara Reservoir in Algeria. In Energy, Transportation and Global Warming; Grammelis, P., Ed.; Springer International Publishing: Cham, Germany, 2016; pp. 635–653. [Google Scholar]
  9. Guettaf, M.; Maoui, A.; Ihdene, Z. Assessment of water quality: A case study of the Seybouse River (North East of Algeria). Appl. Water Sci. 2017, 7, 295–307. [Google Scholar] [CrossRef]
  10. Hadji, R.; Limani, Y.; Baghem, M.; Demdoum, A. Geologic, topographic and climatic controls in landslide hazard assessment using GIS modeling: A case study of Souk Ahras region, NE Algeria. Quat. Int. 2013, 302, 224–237. [Google Scholar] [CrossRef]
  11. Boudoukha, A.; Boulaarak, M. Waters pollution of Hammam Grouz Dam by nutrients (East of Algeria). Bull Serv. Geol. 2013, 24, 23–34. [Google Scholar]
  12. Demdoum, A.; Hamed, Y.; Feki, M.; Hadji, R.; Djebbar, M. Multi-tracer investigation of groundwater in El Eulma Basin (Northwestern Algeria), North Africa. Arab. J. Geosci. 2015, 8, 3321–3333. [Google Scholar] [CrossRef]
  13. Hamad, A.; Baali, F.; Hadji, R.; Zerrouki, H.; Besser, H.; Mokadem, N.; Legrioui, R.; Hamed, Y. Hydrogeochemical characterization of water mineralization in Tebessa-Kasserine karst system (Tuniso-Algerian Transboundry basin). Euro-Mediterr. J. Environ. Integr. 2018, 3, 1–15. [Google Scholar] [CrossRef]
  14. Hamed, Y.; Redhaounia, B.; Sâad, A.; Hadji, R.; Zahri, F.; Zighmi, K. Hydrothermal waters from karst aquifer: Case study of the Trozza basin (Central Tunisia). J. Tethys 2017, 5, 33–44. [Google Scholar]
  15. Ferahtia, A.; Halilat, M.T.; Mimeche, F.; Bensaci, E. Surface water quality assessment in semi-arid region (El hodna watershed, Algeria) based on water quality index (WQI). Stud. Univ. Babes-Bolyai Chem. 2021, 66, 127–142. [Google Scholar] [CrossRef]
  16. Iqbal, M.M.; Shoaib, M.; Farid, H.U.; Lee, J.L. Assessment of Water Quality Profle Using Numerical Modeling Approach in Major Climate Classes of Asia. Int. J. Environ. Res. Public Health 2018, 15, 2258. [Google Scholar] [CrossRef]
  17. Uddin, M.G.; Nash, S.; Olbert, A.I. A review of water quality index models and their use for assessing surface water quality. Ecol. Indic. 2021, 122, 107218. [Google Scholar] [CrossRef]
  18. Zandagba, J.E.B.; Adandedji, F.M.; Lokonon, B.E.; Chabi, A.; Dan, O.; Mama, D. Application use of Water Quality Index (WQI) and multivariate analysis for Nokoué lake water quality assessment. Am. J. Environ. Sci. Eng. 2017, 1, 117–127. [Google Scholar]
  19. Egun, N.K.; Oboh, I.P. Surface Water Quality Evaluation of Ikpoba Reservoir, Edo State, Nigeria. Int. J. Energy Water Resour. 2022, 6, 509–519. [Google Scholar] [CrossRef]
  20. Şener, Ş.; Şener, E.; Davraz, A. Evaluation of water quality using water quality index (WQI) method and GIS in Aksu River (SW-Turkey). Sci. Total Environ. 2017, 584, 131–144. [Google Scholar] [CrossRef] [PubMed]
  21. Ammari, A. Vulnérabilité à l’Envasement des Barrages (cas du Bassin Hydrographique des Côtiers Algérois). Thèse de Doctorat en Sciences en Hydraulique. Ph.D Thesis, Université Mohamed Khider, Biskra, Algérie, 2012. [Google Scholar]
  22. APHA. Standard Methods for the Examination of Water and Wastewater, 22nd ed.; Rice, E.W., Baird, R.B., Eaton, A.D., Clesceri, L.S., Eds.; American Public Health Association (APHA); American Water Works Association (AWWA); Water Environment Federation (WEF): Washington, DC, USA, 2012. [Google Scholar]
  23. Doherty, E.; McNamara, G.; Fitzsimons, L.; Clifford, E. Design and implementation of a performance assessment methodology cognisant of data accuracy for Irish wastewater treatment plants. J. Clean. Prod. 2017, 165, 1529–1541. [Google Scholar] [CrossRef]
  24. Hoffman, J.I. Chapter 9-Outliers and Extreme Values. Basic Biostat. Med. Biomed. Pract. 2019, 2, 149–155. [Google Scholar]
  25. Chantarangkul, V.; Peyvandi, F.; Tripodi, A.; Group, I. Effect of different methods for outlier detection and rejection when calculating cut off values for diagnosis of lupus anticoagulants. Thromb. Res. 2020, 190, 20–25. [Google Scholar] [CrossRef]
  26. Tukey, J.W. Exploratory Data Analysis; Springer: Berlin/Heidelberg, Germany, 1977; Volume 2, pp. 131–160. [Google Scholar]
  27. Le Guen, M. TUKEY’s boxplot, a tool for learning about statistics. Stat. Your-SFDS 2001, 4, 1–3. [Google Scholar]
  28. Berenguer-Rico, V.; Nielsen, B. Normality testing after outlier removal. Econom. Stat. 2023. [Google Scholar] [CrossRef]
  29. Razali, N.M.; Wah, Y.B. Power comparisons of shapiro-wilk, kolmogorov-smirnov, lilliefors and anderson-darling tests. J. Stat. Model. Anal. 2011, 2, 21–33. [Google Scholar]
  30. World Health Organization. Nitrate and Nitrite in Drinking-Water. Background Document for Development of WHO Guidelines for Drinking-Water Quality. Available online: https://www.who.int/docs/default-source/wash-documents/wash-chemicals/nitrate-nitrite-background-document.pdf (accessed on 10 July 2023).
  31. Shaibur, M.R.; Hossain, M.S.; Sony, S.J. Drinking water quality of hand tube well water at sub-urban areas of Jashore Municipality, Bangladesh. J. Jessore Univ. Sci. Technol. 2019, 4, 11–22. [Google Scholar]
  32. Edori, O.S.; Nna, P.J. Determination of physicochemical parameters of effluents at discharge points into the New Calabar River along Rumuolumeni axis, Niger Delta, Nigeria. J. Environ. Anal. Toxicol. 2018, 8, 2161-0525. [Google Scholar]
  33. Jehan, S.; Ullah, I.; Khan, S.; Muhammad, S.; Khattak, S.A.; Khan, T. Evaluation of the Swat River, Northern Pakistan, water quality using multivariate statistical techniques and water quality index (WQI) model. Environ. Sci. Pollut. Res. 2020, 27, 38545–38558. [Google Scholar] [CrossRef]
  34. Mohammed, A.Q.; Mouhcine, E.Q.; Nabil Darwesh, M.S.; Hamdaoui, F.; Kherrati, I.; El Kharrim, K.; Belghyti, D. Hydrogeochemical study of groundwater quality in the west of Sidi Allal Tazi, Gharb area, Morocco. J. Mater. Environ. Sci. 2017, 9, 293–304. [Google Scholar]
  35. CCME (Canadian Council of Ministers of the Environment). Canadian Environmental Quality Guidelines for the Protection of Aquatic Life, CCME Water Quality Index: Technical Report, Canadian Council of Ministers of the Environment: Winnipeg, Manitoba, 2001.
  36. Bouhezila, F.; Hacene, H.; Aichouni, M. Water quality assessment in Reghaia (North of Algeria) lake basin by using traditional approach and water quality indices. Kuwait J. Sci. 2020, 47, 57–71. [Google Scholar]
  37. Fathi, P.; Ebrahimi Dorche, E.; Zare Shahraki, M.; Stribling, J.; Beyraghdar Kashkooli, O.; Esmaeili Ofogh, A.; Bruder, A. Revised Iranian Water Quality Index (RIWQI): A tool for the assessment and management of water quality in Iran. Environ. Monit. Assess. 2022, 194, 504. [Google Scholar] [CrossRef]
  38. Ojukwu, C.K.; Okeah, G.O.C.; Mmom, P.C. A Comparative Analysis of the Weighted Arithmetic and Canadian Council of Ministers of the Environment Water Quality Indices for Water Sources in Ohaozara, Ebonyi State, Nigeria. Int. J. Eng. Res. Technol. (IJERT) 2021, 10, 498–506. [Google Scholar]
  39. Bessedik, M.; Abdelbaki, C.; Badr, N.; Tiar, S.M.; Megnounif, A. Application of water quality indices for assessment of influent and effluent wastewater from wastewater treatment plant of Oran City, Algeria. Desalination Water Treat. 2021, 236, 306–317. [Google Scholar] [CrossRef]
  40. Zahedi, S. Modification of expected conflicts between drinking water quality index and irrigation water quality index in water quality ranking of shared extraction wells using multi criteria decision making techniques. Ecol. Indic. 2017, 83, 368–379. [Google Scholar] [CrossRef]
  41. Varol, M.; Gökot, B.; Bekleyen, A.; Şen, B. Spatial and temporal variations in surface water quality of the dam reservoirs in the Tigris River basin, Turkey. Catena 2012, 92, 11–21. [Google Scholar] [CrossRef]
  42. Sawyer, C.N.; McCarty, P.L.; Parkin, G.F. Chemistry for Environmental and Engineering Science, 5th ed.; McGraw Hill Inc.: New York, NY, USA, 2003; pp. 587–590. [Google Scholar]
  43. Ireland-EPA. Parameters of Water Quality—Interpretation and Standards; Environmental Protection Agency: Wexford, Republic of Ireland, 2001. [Google Scholar]
  44. Karakaya, N.; Evrendilek, F. Water quality time series for Big Melen stream (Turkey): Its decomposition analysis and comparison to upstream. Environ. Monit. Assess. 2010, 165, 125–136. [Google Scholar] [CrossRef]
  45. People’s Democratic Republic of Algeria. Law No. 83-03 of February 5, 1983 Relating to Environmental Protection. Official Journal of the Democratic and Popular Algerian Republic No. 6, February 8, 1983, p. 250.(pdf). (This Document Is in French). Available online: https://leap.unep.org/en/countries/dz/national-legislation/loi-n-83-03-relative-la-protection-de-lenvironnement (accessed on 15 March 2024).
  46. Ghemmit-Doulache, N.; Ouslimani, N. Water Quality Control of Three Sites At Kedarra Barrage. J. Fundam. Appl. Sci. 2021, 13, 965–981. [Google Scholar]
  47. Guettache, A.; Bettayeb, S.; Ililes, M. Caractérisation et Étude D’efficacité du Système de Traitement de l’eau de Barrage Keddara. Available online: http://dspace.univ-bouira.dz:8080/jspui/handle/123456789/11443 (accessed on 15 March 2024).
  48. Soltani, A.A.; Bermad, A.; Boutaghane, H.; Oukil, A.; Abdalla, O.; Hasbaia, M.; Oulebsir, R.; Zeroual, S.; Lefkir, A. An integrated approach for assessing surface water quality: Case of Beni Haroun dam (Northeast Algeria). Environ. Monit. Assess. 2020, 192, 1–17. [Google Scholar] [CrossRef]
  49. Arab, S.; Bouchelouche, D.; Hamil, S.; Arab, A. Application of water quality index for surface water quality assessment Boukourdane Dam, Algeria. In Advances in Sustainable and Environmental Hydrology, Hydrogeology, Hydrochemistry and Water Resources, Proceedings of the 1st Springer Conference of the Arabian Journal of Geosciences (CAJG-1), Tunisia, 2018; Springer International Publishing: Berlin/Heidelberg, Germany, 2019; pp. 385–387. [Google Scholar]
  50. Hamlat, A.; Tidjani, A.E.B.; Yebdri, D.; Errih, M.; Guidoum, A. Water quality analysis of reservoirs within Western Algeria catchment areas using water quality index CCME WQI. J. Water Supply Res. Technol.—AQUA 2014, 63, 311–332. [Google Scholar] [CrossRef]
Figure 1. Location of the Keddara Dam (36°39′03.0″ N 3°24′58.9″ E).
Figure 1. Location of the Keddara Dam (36°39′03.0″ N 3°24′58.9″ E).
Water 16 01291 g001
Figure 2. Boxplot of the Keddara data before removal of outliers.
Figure 2. Boxplot of the Keddara data before removal of outliers.
Water 16 01291 g002
Table 3. CCME WQI scale [35].
Table 3. CCME WQI scale [35].
CCME WQIsQuality RangeWater Categories
95–100ExcellentNatural water quality
80–94GoodWater quality is departed from natural or desirable levels
65–79FairWater quality condition sometimes departs from natural or desirable levels.
45–64MarginalWater quality is frequently threatened or impaired; conditions often depart from natural or desirable level
0–44PoorWater quality is not suitable for use purposes at any level.
Table 4. WAM WQI Scale [36].
Table 4. WAM WQI Scale [36].
WQI Value Rating of Water Quality Grading
0–25Excellent water quality A
26–50Good water quality B
51–75Poor water quality C
76–100Very poor water quality D
>100Unsuitable for drinking E
Table 5. Descriptive characteristics of the Keddara Dam.
Table 5. Descriptive characteristics of the Keddara Dam.
ParametersTemp.
°C
pHEC μS/cmTurb. NTUTSS mg/LTH
F0
TAC
F0
NO2
mg/L
NO3 mg/LNH4+
mg/L
PO43−
mg/L
Minimum11.707.59881.301.3029.015.600.002.270.000.015
Q114.507.8211473.683.5939.017.200.023.960.0150.015
Median16.907.9612315.906.4042.817.800.026.310.0150.015
Mean (Q2)17.747.9312436.726.6842.1817.570.036.680.0230.025
Q320.908.0413589.088.8645.4018.000.035.850.0190.032
Max (Q4)25.308.32152523.7022.0050.6020.800.2210.000.230.095
Min outlier4.97.49830.5−4.42−4.3229.4160.003−0.970.010.011
Maj outlier30.58.371674.517.1816.775519.20.04912.180.0250.058
Permissible limit (WHO)26.58.515005305020350≤0.50.5
Table 6. Normality test of the Keddara water quality parameters.
Table 6. Normality test of the Keddara water quality parameters.
Water ParametersSample SizeShapiro–Wilk TestKolmogorov Test
Temperature 309 1.12 × 10−100.86810.94
pH 309 4.853 × 10−60.99820.97
Conductivity 309 6.243 × 10−60.48460.98
Turbidity 309 2.877 × 10−90.98260.95
Total dissolved solids (TSS) 55 0.10750.78540.98
Hydrometric title (TH) 24 0.15990.65740.95
Full alkalimetric title (TAC) 23 0.37490.830.96
Nitrogen oxide (NO2) 104 <2.2 × 10−160.44720.29
Nitrate (NO3) 28 0.27890.98410.97
Ammonia (NH4+) 110 <2.2 × 10−160.44720.34
Phosphate ion (PO43−) 104 1.325 × 10−140.44720.63
Table 7. Results for CCME WQI and WAM WQI methods.
Table 7. Results for CCME WQI and WAM WQI methods.
Years29 December 2018–29 March 2019 3 April 2019–28 September 2019 2 October 2019–31 March 2020 4 April 2020–29 September 2020 2 October 2020–31 March 2021 3 April 2021–3 June 2021
Season WetDryWetDry Wet Dry
CCME WQI Total number of tests 177 383383 297 348 96
Number of field parameters 111112
Number of failed tests 31 76 4321 63 20
F19.09 9.09 9.099.099.09 18.18
F2 7.51 7.1511.237.07 18.10 20.83
F3 12.692.54 3.192.06 16.99 14.68
WQI 86.45 93.16 91.4695.09 88.34 81.92
Quality range Good Good Good Excellent Good Good
WAM WQI WQI 14.68 9.52 11.23 12.45 17.7715.99
Quality range Excellent Excellent Excellent Excellent Excellent Excellent
Table 8. Comparison between the Keddara Dam WQIs and other Algerian case studies.
Table 8. Comparison between the Keddara Dam WQIs and other Algerian case studies.
StudyMethod UsedWater QualityReference
Case StudyLambert Coordinates
Keddara Dam36°39′03″ N, 3°24′59″ ECCME-WQIAcceptable to excellentThis study
WAM-WQIExcellent
Reghaia lake36°46′17″ N, 3°20′38″ ECCME-WQIUnsuitable[36]
WAM-WQIPoor
Beni Haroun Dam36°33′19″ N, 6°16′11″ ECCME-WQIPoor[48]
Boukourdane Dam36°31′40″ N, 2°18′14″ ENSF-WQIimpaired[49]
Hammam Boughrara Dam34°53′03″ N, 1°38′51″ WCCME-WQIPoor[50]
Sikkak Dam35°02′42″ N, 1°20′27″ WCCME-WQIMarginal[50]
Cheurfa Dam35°24′11″ N, 0°15′14″ WCCME-WQIMarginal[50]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Fashagba, T.S.; Bessedik, M.; ElSayed, N.B.; Abdelbaki, C.; Kumar, N. Evaluating the Water Quality of the Keddara Dam (Algeria) Using Water Quality Indices. Water 2024, 16, 1291. https://doi.org/10.3390/w16091291

AMA Style

Fashagba TS, Bessedik M, ElSayed NB, Abdelbaki C, Kumar N. Evaluating the Water Quality of the Keddara Dam (Algeria) Using Water Quality Indices. Water. 2024; 16(9):1291. https://doi.org/10.3390/w16091291

Chicago/Turabian Style

Fashagba, Tosin Sarah, Madani Bessedik, Nadia Badr ElSayed, Chérifa Abdelbaki, and Navneet Kumar. 2024. "Evaluating the Water Quality of the Keddara Dam (Algeria) Using Water Quality Indices" Water 16, no. 9: 1291. https://doi.org/10.3390/w16091291

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop