Article

Seat Occupancy Detection Based on a Low-Power Microcontroller and a Single FSR †

by
Ernesto Sifuentes
1,
Rafael Gonzalez-Landaeta
1,*,
Juan Cota-Ruiz
1 and
Ferran Reverter
2
1
Department of Computer and Electrical Engineering, Universidad Autónoma de Ciudad Juárez (UACJ), Ciudad Juárez 32310, Mexico
2
Department of Electronic Engineering, Universitat Politècnica de Catalunya (UPC)–BarcelonaTech, Castelldefels, 08860 Barcelona, Spain
*
Author to whom correspondence should be addressed.
This paper is an extended version of the conference paper: Sifuentes, E.; González-Landaeta, R.; Cota-Ruiz, J.; Reverter, F. Microcontroller-Based Seat Occupancy Detection and Classification. In Proceedings of the EUROSENSORS 2018, Graz, Austria, 9–12 September 2018.
Sensors 2019, 19(3), 699; https://doi.org/10.3390/s19030699
Submission received: 26 December 2018 / Revised: 5 February 2019 / Accepted: 5 February 2019 / Published: 8 February 2019
(This article belongs to the Special Issue Eurosensors 2018 Selected Papers)

Abstract

:
This paper proposes a microcontroller-based measurement system to detect and confirm the presence of a subject in a chair. The system relies on a single Force Sensing Resistor (FSR), which is arranged in the seat of the chair, that undergoes a sudden resistance change when a subject/object is seated/placed over the chair. In order to distinguish between a subject and an inanimate object, the system also monitors small-signal variations of the FSR resistance caused by respiration. These resistance variations are then directly measured by a low-cost general-purpose microcontroller unit (MCU) without using either an analogue processing stage or an analogue-to-digital converter. Two versions of such a MCU-based circuit are presented: one to prove the concept of the measurement, and another with a smart wake-up (generated by the sudden resistance change) intended to reduce the energy consumption. The feasibility of the proposed measurement system is experimentally demonstrated with subjects of different weight sitting at different postures, and also with objects of different weight. The MCU-based circuit with a smart wake-up shows a standby current consumption of 800 nA, and requires an energy of 125 µJ to carry out the measurement after the wake-up.

1. Introduction

Seat-occupancy monitoring systems generally use mechanical sensors that detect weight, pressure, force or acceleration over the seat. These mechanical sensors can be resistive [1], capacitive [2] or inductive [3], but the former are the most common. Different types of resistive mechanical sensors can be employed, for instance: metallic strain gauges, semiconductor strain gauges and force sensing resistors (FSR), the latter being the cheapest and the most easily integrated into the chair structure. Mechanical sensors, however, have difficulties in distinguishing between subjects and objects seated/placed over the seat. This is usually solved by comparing the set of data to known patterns [4] or by combining the information of different types of sensor. For example, in [5], the information of the resistive mechanical sensor is combined with that provided by two additional sensors: a thermal sensor and a capacitive proximity sensor. The combination of proximity sensors, instead of mechanical sensors, have also been reported for seat-occupancy monitoring systems, as suggested in [6] by combining inductive and capacitive proximity sensors.
Resistive mechanical sensors, integrated in wheelchairs and conventional chairs, also play a significant role in health telemonitoring applications. However, several sensors are generally required to carry out the measurement of interest. For instance, the sitting posture has been proposed to be detected by employing: four load cells arranged in the seat of a chair in [7] and twelve FSRs distributed in both the seat and the backrest of a wheelchair in [8]. The respiratory signal has also been monitored using resistive mechanical sensors, for example: four FSRs attached to the backrest of a conventional chair in [9], and nine FSRs distributed in both the seat and the backrest of a wheelchair in [10].
This paper, which continues and expands the work presented in [11], proposes a novel measurement method for seat occupancy detection and classification using a single FSR. The additional information usually required for the subject-object classification is extracted from the FSR itself, which is exploited to monitor the respiratory signal similarly to the applications described in the previous paragraph. It is expected that the occupancy causes a large-signal variation of the FSR, whereas the respiration generates a small-signal variation enabling the confirmation of the presence of a subject rather than an object.
As for the read-out electronic circuit, it is proposed to read both large- and small-signal variations of the FSR applying the concept of direct interface circuit (DIC) [12], where the sensor is directly connected to a low-cost microcontroller unit (MCU) without using intermediate analogue electronics either an analogue-to-digital converter (ADC). These MCU-based circuits have been extensively analyzed and proved for resistive [13,14,15], capacitive [16,17,18] and inductive [19,20] sensors with different topologies, but not for resistive sensors undergoing both large- and small-signal variations, as we have in the application of interest here. DICs have also been suggested for sensors providing a quasi-static analogue output voltage [21,22] and as a versatile interface circuit for the measurement of different types of sensor [23].
According to the last two paragraphs, the main contribution of this paper is the proposal of a MCU-based circuit to detect and confirm the presence of a subject seated over a chair using a single FSR. The same sensor is employed to wake-up the MCU in the presence of a subject/object, and then to monitor the respiratory signal to confirm the presence of a subject. Moreover, this is carried out without using any intermediate analogue electronics, thus resulting in a low-power, low-cost design solution. Consequently, the proposed method is attractive for autonomous sensor applications that require the detection and confirmation of people sitting in chairs, such as intelligent airbag deployment systems and aircraft boarding systems.
The paper is organized as follows. Section 2 describes the operating principle of the seat occupancy detection and classification technique. Section 3 explains how the FSR is measured through the DIC and proposes an improved version with a smart wake-up so as to reduce its energy consumption. Section 4 describes the setup and the measurement method. Section 5 shows and discusses the experimental results. Finally, Section 6 draws the main conclusions.

2. Operating Principle

The proposed method for the seat occupancy detection and classification relies on a single FSR attached at the center of the seat. A FSR is a sensor whose resistance (Rx) decreases with increasing the force applied to it; in the application of interest, the force will be exerted by the subject/object seated/placed over the chair. This is a very low-cost, thin-size resistive mechanical sensor that can be easily integrated into the chair structure; however, it has limitations in terms of accuracy, linearity, interchangeability and time drifts. The repeatability due to time drifts can be quite critical when the FSR is subjected to a static loading for a long time interval (say, some hours), but it is quite acceptable (at least for FSRs from Interlink Electronics) when the FSR is subjected to a dynamic loading for a short time interval (say, a few seconds) [24]. The previous limitations are not expected to be critical here since the aim is to monitor resistance variations due to respiration in a few seconds, and not to determine the exact value of the subject/object weight nor the respiratory rate.
The operating principle of the proposed measurement method is shown in Figure 1, where three scenarios are possible: (1) The seat is vacant: Rx remains constant with respect to Rx,0, which is the nominal resistance under zero-force conditions. (2) A subject is seated over the chair: Rx suddenly decreases (e.g., from Rx,0 to Rx,1) due to the subject’s weight. Then, as the subject stays there, his/her respiration causes small-signal variations of Rx (∆Rx in Figure 1a) that enables us to confirm the presence of a subject. (3) An inanimate object is placed over the chair: Rx undergoes a sudden decrease due to the object’s weight, but remains constant at Rx,2, as shown in Figure 1b. Therefore, according to Figure 1, if the measurement system is able to detect such small-signal variations caused by respiration, the subject-object classification can be carried out using a single resistive mechanical sensor.

3. Read-out Interface Circuit

The FSR variations shown in Figure 1 are proposed to be measured by a low-cost general-purpose MCU applying the DIC concept [12]. The MCU only needs to have an embedded digital timer and a few input/output (I/O) digital port pins; no analogue (e.g., comparator) or mixed (e.g., ADC) embedded peripherals are required. Next, two proposals for the MCU-based circuit are presented. The first one is a basic topology that will enable us to prove the measurement method introduced in Section 2, whereas the second one is an energy-efficient topology with a smart wake-up.

3.1. Basic Read-out Circuit

The basic topology of the DIC to read the FSR is shown in Figure 2a. First of all, note that the FSR has a resistor (Rp) in parallel so as to linearize its response and also to avoid long measurements in zero-force conditions. The operating principle of this circuit is as follows. Initially, Pin 1 provides a digital ‘1’ and Pin 2 is in high-impedance (HZ) state and, consequently, the well-known capacitor C is quickly charged to the supply voltage (VDD). Next, Pin 1 is in HZ and Pin 2 provides a digital ‘0’ so that C is discharged towards ground through the equivalent resistance (Req = RpRx). In the meantime, an embedded timer (which uses a high-frequency clock signal as a reference) measures the time interval required to do the discharge. When the exponential discharging voltage crosses the threshold voltage (VT) of the digital buffer embedded into Pin 1, the timer is stopped, as shown in Figure 2b. The resulting digital number stored in the timer is proportional to the discharging time (Td) and also to Req, since Td = Req·C·ln(VDD/VT) [12]; this is valid provided that Req is much higher than the parasitic output resistance of the I/O pins involved in the measurement. For a given Td and assuming that C, VDD and VT are known, Req can be estimated as
R eq = T d C In ( V DD / V T )
Unlike the circuits proposed in [12,13], the circuit in Figure 2a does not require any reference resistor because the information to be monitored is on the change, not in the absolute value.

3.2. Read-out Circuit with a Smart Wake-up

The main limitation of the circuit shown in Figure 2a is that the presence of a subject/object over the chair is detected by polling, thus involving unnecessary energy consumption especially when the seat is vacant. This can be improved using the DIC-based topology shown in Figure 3, which has a smart wake-up generated by the FSR itself when a sudden decrease of resistance occurs. In other words: the MCU is in a deep sleep mode by default, but when a sudden decrease of resistance happens, the MCU wakes up and measures the FSR in the same way indicated in Section 3.1. This kind of smart wake-up in MCU-based circuits was also proposed in [5,25], but employing a sensor for the wake-up and another for the measurement of interest. Here, the FSR is employed for both purposes.
The operating principle of the circuit shown in Figure 3 is the following. Initially, the MCU is in a deep sleep mode and the circuit is configured as a voltage divider using a series resistance (Rs). The pins are configured as: Pin 3 provides a digital ‘1’, Pin 2 is set as external interruption with falling edge attention, Pin 1 provides a digital ‘0’, and Pin 4 is in HZ. Note that the current consumption of this voltage divider is very low since the FSR offers a very high resistance in zero-force conditions. When a subject/object is seated/placed over the FSR, its resistance suddenly decreases and, consequently, the output (Vint) of the voltage divider also decreases, thus generating an external interruption attended by Pin 2. In such a case, the MCU wakes up and then measures the FSR as described in Section 3.1. In comparison with the circuit shown in Figure 2a, there are two differences: (1) Pin 3 is set in HZ and Pin 4 provides a digital ‘0’ during the charge-discharge process shown in Figure 2b, and (2) Rp is not required here since the sensor resistance is quite low when a subject/object is seated/placed over the chair and, hence, the discharging time is not expected to be so long. Therefore, in such a topology, we have Req = Rx during the discharge process.
Once the MCU is awake, the measurement of Td is repeated n times with a sampling frequency of fs during an acquisition time of Tacq (= n/fs) that should be long enough to appropriately monitor the respiratory signal. The main energy consumption occurs when charging C to VDD and when measuring Td with a timer running at high frequency so as to reduce the effects of quantization. Accordingly, the energy required to carry out the complete measurement can be approximated as
E V DD C [ V DD + I timer R eq ln ( V DD V T ) ] f s T acq
where Itimer is the current consumption of the timer in charge of measuring Td. This is valid provided that the current consumption of the MCU while controlling both the charging stage and the sampling frequency is negligible. Note that these two tasks can easily be controlled by a timer running at low frequency (e.g., 32 kHz) [26] that generally involves a current consumption smaller than 1 µA. The consumption related to the data processing is not considered in Equation (2).
An algorithm to be executed by the MCU for the subject-object classification is proposed in Figure 4. When the MCU wakes up from the deep sleep mode, it measures Td up to n times and the result is stored in a 16-bit variable Ni. From the set of measurements, the maximum (Nmax) and minimum (Nmin) values are found; a low-pass filter processing of the data could be required before determine Nmax and Nmin so as to avoid the effects of aberrant measurements. Afterwards, the difference (ΔN) between Nmax and Nmin is calculated. If such a difference is higher than a given threshold level, the presence of a subject is confirmed. As explained later in Section 5.2, the circuit in Figure 3 is expected to operate at fs = 2 Sa/s during Tacq = 10 s and, therefore, 20 samples of Td (of 16 bits) will be stored. This involves 40 bytes of RAM, which are available in most MCUs.

4. Materials and Method

4.1. General

A commercial FSR (FSR 406 from Interlink Electronics) was arranged in the center of the seat of a conventional chair. This FSR has Rx,0 > 10 MΩ, an active area of 4 × 4 cm2 and a rise time lower than 3 µs. The sensor was then connected to a DIC implemented by a low-cost, low-power MCU (MSP430F123 from Texas Instruments, Dallas, TX, USA) operating at 8 MHz and powered at VDD = 3.3 V. This MCU has several Low-Power Modes (LPM) to control which on-chip circuitry, such as the central processing unit (CPU) and peripherals, is active. It also has 256 bytes of RAM.
An embedded 16-bit timer (running at 8 MHz and operating in LPM3) measured Td as in Figure 2b. Several samples of Td were taken at a sampling frequency of fs, which was controlled by another embedded timer. The frequency of the respiratory signal is expected to be very low (lower than 1 Hz) and, hence, fs ≥ 2 Sa/s following the Nyquist criterion. Each sample of Td was transmitted in real time to a personal computer and, then, converted to the corresponding value of Req applying Equation (1) through a control program implemented in LabVIEWTM.
The proposed measurement system was experimentally tested with three healthy subjects of different weight and age (S1: 45 kg/14 years; S2: 64 kg/39 years; S3: 91 kg/41 years), and also with three objects of different weight (O1: 5 kg; O2: 10 kg; O3: 30 kg). The volunteers were asked to position themselves over the chair and breathe freely, but to keep quiet during the measurement so as to avoid movement artifacts. Four different sitting postures of the subject were also tested, as shown in Figure 5. The idea of placing the FSR at the backrest was not considered because the signal detected would be insignificant in certain sitting postures, such as P3 in Figure 5.
The measurements of current consumption were carried out by a digital electrometer (Keithley 6514) following the procedures indicated in [26].

4.2. Basic Read-out Circuit

The circuit in Figure 2a was tested using Rp = 3570 Ω, and different values of C (470 nF, 1 µF and 2.2 µF) and fs (2, 20 and 60 Sa/s). The values of C were high enough to have a good resolution in the measurement of Td and, hence, of Req [27]. The selected value of Rp (together with the maximum value of C) generated Td ≤ 8 ms, thus avoiding the overflow of the timer in zero-force conditions.
The function of Pin 1 and Pin 2 in Figure 2a was implemented by pins P1.1 and P1.2, respectively, which are general-purpose I/O digital pins. The former has a Schmitt-Trigger buffer with VT = 1.2 V and is associated with a capture module that automatically captures the value of the timer when the external signal crosses VT.

4.3. Read-out Circuit with a Smart-Wake-up

In the circuit shown in Figure 3, the MCU operated by default in LPM4, where the CPU and all clocks are disabled and only the external interruption generated by Pin 2 is enabled; the wake-up time from LPM4 is 6 µs, which is fast enough for the application considered herein. Moreover, the circuit employed Rs = 1 MΩ, which is more than ten times smaller than the FSR resistance in zero-force conditions, thus generating a digital ’1’ at the input of Pin 2 when the seat was vacant. The circuit was optimized in terms of energy consumption using the minimum values of C (470 nF) and fs (2 Sa/s) from those indicated in Section 4.2, as suggested by Equation (2).
The function of pins 1, 2, 3 and 4 in Figure 3 was implemented by pins P1.1, P1.2, P1.3 and P1.4, respectively. In addition to the features indicated in the second paragraph of Section 4.2, P1.2 was configured as an external interruption to automatically wake the MCU from LPM4 when the FSR underwent a sudden change.

5. Experimental Results and Discussion

5.1. Basic Read-out Circuit

The experimental results of the circuit in Figure 2a for different subjects are shown in Figure 6a. When a subject sat down (at t ≈ 10 s), a large-signal variation (between 600 and 2400 Ω) was observed, and this depended on the subject’s weight. For the heaviest subject (S3), the resistance dropped to an average value of about 1250 Ω. While seated, small-signal resistance variations of around ±125 Ω with a respiratory rate between 12 (for S3) and 24 (for S1) breaths per minute, which correspond to a frequency between 0.2 and 0.4 Hz, were monitored. This well-defined respiratory signal clearly confirms the presence of a subject over the chair without incorporating any other sensor.
The results when placing different objects over the chair are represented in Figure 6b, which only shows a large-signal variation due to the object’s weight but not the small-signal variations. It is worth mentioning that in Figure 6b the large-signal variation is similar and even higher than that in Figure 6a although the weight is lower. This is because the objects under test had small dimensions and, consequently, their weight caused a “point” force on the FSR that was higher than the corresponding component of distributed force generated by the subject.
Figure 7, Figure 8 and Figure 9 show the small-signal resistance variations monitored for different values of fs, C and sitting posture, respectively. According to Figure 7, a sampling frequency of 2 Sa/s seems to be enough to recover the frequency of the respiratory signal, with the corresponding benefits in terms of energy consumption. From Figure 8, a low-value capacitor (470 nF) seems valid to detect the resistance variations involved in the measurement, thus reducing the energy consumption of the circuit even more. According to Figure 9, the amplitude of the small-signal resistance variation was quite similar for the four sitting postures under test. Posture P3 generated the highest large-signal variation at the instant at which the seat was occupied, whereas posture P4 provided a more unstable signal probably because of the crossed leg.

5.2. Read-out Circuit with a Smart Wake-up

The experimental results of the circuit in Figure 3 for different subjects and objects are shown in Figure 10a,b, respectively, assuming that t = 0 is the instant at which the subject/object is seated/placed over the chair, thus waking up the MCU. Although the values of C and fs were low so as to reduce the energy consumption, the circuit was able to recover the frequency of the respiratory signal and to detect the resistance variations caused by respiration, as clearly shown in Figure 10a. If an object was placed over the chair instead of a subject, the resulting Req was almost constant over time after the wake-up, as shown in Figure 10b. Accordingly, the subject-object classification is also feasible with the circuit in Figure 3. An appropriate threshold level (see Figure 4) for the classification could be, for instance, 50 Ω, which corresponds to ΔN = 188 counts under the operating conditions indicated before. From Figure 10a, the acquisition time should be around 10 s in order to have enough samples (even for very low respiratory rates) that enable the detection of the respiratory signal. The effects of the sitting posture when using the circuit in Figure 3 are represented in Figure 11, which shows a performance quite similar to that represented before in Figure 9.
The current consumption of the circuit shown in Figure 3 in LPM4 (i.e., when waiting for an interruption generated by a subject/object) was 800 nA, including the current of the voltage divider formed by Rs and FSR. On the other hand, the current consumption of the embedded timer (at 8 MHz and in LPM3) while measuring Td was 500 µA. According to Equation (2) and assuming VDD = 3.3 V, VT = 1.2 V, C = 470 nF, Itimer = 500 µA, Req = 1600 Ω, fs = 2 Sa/s, and Tacq = 10 s, the energy required is 125 µJ. Therefore, in case of using a lithium battery of 3.6 V − 1 Ah, the circuit in Figure 3 would have autonomy to check more than 100 million times if the interruption was generated by a subject or an object. Taking into account that the circuit in Figure 3 was clearly able to detect the resistance variations caused by respiration, the discharging-time measurement could also be carried out at a lower operating frequency (e.g., 1 MHz instead of 8 MHz), thus reducing even more the energy required since Itimer would be smaller. However, the previous estimation of the autonomy would be shorter if the system had a transceiver circuit whose energy consumption can be quite significant.

6. Conclusions

This work has proved that detecting and confirming the presence of a subject in a chair is feasible using a single FSR directly connected to a general-purpose MCU. The proposed system first detects the subject by monitoring his/her weight and then confirms his/her presence by monitoring the respiration. The proposed MCU-based circuit has also been improved in terms of energy consumption by incorporating a smart wake-up generated by the FSR itself. In such a way, the MCU is by default in a deep sleep mode. We believe the proposed system is suitable for applications related to autonomous sensors where it is important to detect and confirm the presence of people sitting in chairs, such as intelligent airbag deployment systems and aircraft boarding systems.

Author Contributions

R.G.-L. and E.S. proposed the main idea and, together with J.C.-R., built the measurement setup, performed the experiments and analyzed the data. F.R. interpreted the results and wrote the manuscript. All the authors approved the final version of the manuscript.

Acknowledgments

Rafael González-Landaeta, Ernesto Sifuentes and Juan Cota-Ruiz were funded by PRODEP and UACJ, México. The work of Ferran Reverter was supported by the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund under project TEC2016-76991-P.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Oestreicher, R.; Homann, M.; Lichtinger, H.; Morell, S.; Reich, D. Method and System for Determining Weight and Position of a Vehicle Seat Occupant. U.S. Patent 7082360, 25 July 2006. [Google Scholar]
  2. Böse, H.; Fuß, E.; Ehrlich, J. Capacitive sensor mats for pressure detection with high sensitivity. In Proceedings of the Sensor and Measurement Technology 2015, Nürnberg, Germany, 19–21 May 2015; pp. 55–60. [Google Scholar]
  3. Kisic, M.G.; Blaz, N.V.; Babkovic, K.B.; Zivanov, L.D.; Damnjanovic, M.S. Detection of seat occupancy using a wireless inductive sensor. IEEE Trans. Magn. 2017, 53, 1–4. [Google Scholar] [CrossRef]
  4. Breed, D.S.; DuVall, W.E.; Johnson, W.C. Dynamic Weight Sensing and Classification of Vehicular Occupants. U.S. Patent 7620521, 17 November 2009. [Google Scholar]
  5. Pallàs-Areny, R.; Casas-Piedrafita, J.O.; Gasulla-Forner, M.; Aliau-Bonet, C.; Gaitan-Pitre, J. Method and Apparatus for the Continuous Detection of Seat Occupancy through the Combined Use of Weight, Capacitive and Thermal Sensors. WO Patent 2011104399, 1 September 2011. [Google Scholar]
  6. George, B.; Zangl, H.; Bretterklieber, T.; Brasseur, G. A combined inductive–capacitive proximity sensor for seat occupancy detection. IEEE Trans. Instrum. Meas. 2010, 59, 1463–1470. [Google Scholar] [CrossRef]
  7. Roh, J.; Park, H.; Lee, K.J.; Hyeong, J.; Kim, S.; Lee, B. Sitting posture monitoring system based on a low-cost load cell using machine learning. Sensors 2018, 18, 208. [Google Scholar] [CrossRef] [PubMed]
  8. Ma, C.; Li, W.; Gravina, R.; Fortino, G. Posture detection based on smart cushion for wheelchair users. Sensors 2017, 17, 719. [Google Scholar] [CrossRef] [PubMed]
  9. Griffiths, E.; Scott, T.; Bernheim, A.J. Health chair: Implicitly sensing heart and respiratory rate. In Proceedings of the ACM Conference on Ubiquitous Computing, Seatle, WA, USA, 13–17 September 2014; pp. 661–671. [Google Scholar]
  10. Pino, E.J.; Arias, D.E.; Aqueveque, P.; Vilugrón, L.; Hermosilla, D.; Curtis, D.W. Monitoring technology for wheelchair users with advanced multiple sclerosis. In Proceedings of the IEEE Engineering in Medicine and Biology Society, Osaka, Japan, 3–7 July 2013; pp. 961–964. [Google Scholar]
  11. Sifuentes, E.; Gonzalez-Landaeta, R.; Cota-Ruiz, J.; Reverter, F. Microcontroller-based seat occupancy detection and classification. In Proceedings of the Eurosensors XXXII, Graz, Austria, 9–12 September 2018. [Google Scholar]
  12. Reverter, F. The art of directly interfacing sensors to microcontrollers. J. Low Power Electron. Appl. 2012, 2, 265–281. [Google Scholar] [CrossRef]
  13. Reverter, F.; Jordana, J.; Gasulla, M.; Pallàs-Areny, R. Accuracy and resolution of direct resistive sensor-to-microcontroller interfaces. Sens. Actuators A Phys. 2005, 121, 78–87. [Google Scholar] [CrossRef]
  14. Nagarajan, P.R.; George, B.; Kumar, V.J. Improved single-element resistive sensor-to-microcontroller interface. IEEE Trans. Instrum. Meas. 2017, 66, 2736–2744. [Google Scholar] [CrossRef]
  15. Oballe-Peinado, O.; Vidal-Verdú, F.; Sánchez-Durán, J.A.; Castellanos-Ramos, J.; Hidalgo-López, J.A. Accuracy and resolution analysis of a direct resistive sensor array to FPGA interface. Sensors 2016, 16, 181. [Google Scholar] [CrossRef] [PubMed]
  16. Reverter, F.; Casas, O. Direct interface circuit for capacitive humidity sensors. Sens. Actuators A Phys. 2008, 143, 315–322. [Google Scholar] [CrossRef]
  17. Pelegrí-Sebastiá, J.; García-Breijo, E.; Ibáñez, J.; Sogorb, T.; Laguarda-Miro, N.; Garrigues, J. Low-cost capacitive humidity sensor for application within flexible RFID labels based on microcontroller systems. IEEE Trans. Instrum. Meas. 2012, 61, 545–553. [Google Scholar] [CrossRef]
  18. Chetpattananondh, K.; Tapoanoi, T.; Phukpattaranont, P.; Jindapetch, N. A self-calibration water level measurement using an interdigital capacitive sensor. Sens. Actuators A Phys. 2014, 209, 175–182. [Google Scholar] [CrossRef]
  19. Kokolanski, Z.; Jordana, J.; Gasulla, M.; Dimcev, V.; Reverter, F. Direct inductive sensor-to-microcontroller interface circuit. Sens. Actuators A Phys. 2015, 224, 185–191. [Google Scholar] [CrossRef]
  20. Ramadoss, N.; George, B. A simple microcontroller based digitizer for differential inductive sensors. In Proceedings of the IEEE International Instrumentation and Measurement Technology Conference, Pisa, Italy, 11–14 May 2015. [Google Scholar]
  21. Bengtsson, L. Direct analog-to-microcontroller interfacing. Sens. Actuators A Phys. 2012, 179, 105–113. [Google Scholar] [CrossRef]
  22. Dutta, L.; Hazarika, A.; Bhuyan, M. Nonlinearity compensation of DIC-based multi-sensor measurement. Measurement 2018, 126, 13–21. [Google Scholar] [CrossRef]
  23. Czaja, Z. Time-domain measurement methods for R, L and C sensors based on a versatile direct sensor-to-microcontroller interface circuit. Sens. Actuators A Phys. 2018, 274, 199–210. [Google Scholar] [CrossRef]
  24. Parmar, S.; Khodasevych, I.; Troynikov, O. Evaluation of flexible force sensors for pressure monitoring in treatment of chronic venous disorders. Sensors 2017, 17, 1923. [Google Scholar] [CrossRef] [PubMed]
  25. Sifuentes, E.; Casas, O.; Pallas-Areny, R. Wireless magnetic sensor node for vehicle detection with optical wake-up. IEEE Sens. J. 2011, 11, 1669–1676. [Google Scholar]
  26. Reverter, F. Power consumption in direct interface circuits. IEEE Trans. Instrum. Meas. 2013, 62, 503–509. [Google Scholar] [CrossRef]
  27. Sifuentes, E.; Gonzalez-Landaeta, R.; Cota-Ruiz, J.; Reverter, F. Measuring dynamic signals with direct sensor-to-microcontroller interfaces applied to a magnetoresistive sensor. Sensors 2017, 17, 1150. [Google Scholar] [CrossRef] [PubMed]
Figure 1. FSR variations when over the chair we have: (a) a subject; (b) an object.
Figure 1. FSR variations when over the chair we have: (a) a subject; (b) an object.
Sensors 19 00699 g001
Figure 2. (a) DIC applied to measure the FSR so as to detect the occupancy of a seat; (b) waveform of the voltage across C during the measurement of the FSR.
Figure 2. (a) DIC applied to measure the FSR so as to detect the occupancy of a seat; (b) waveform of the voltage across C during the measurement of the FSR.
Sensors 19 00699 g002
Figure 3. DIC applied to measure the FSR with a smart wake-up.
Figure 3. DIC applied to measure the FSR with a smart wake-up.
Sensors 19 00699 g003
Figure 4. Flowchart of the proposed algorithm for the subject-object classification.
Figure 4. Flowchart of the proposed algorithm for the subject-object classification.
Sensors 19 00699 g004
Figure 5. Different sitting postures of the subject to test the proposed measurement system.
Figure 5. Different sitting postures of the subject to test the proposed measurement system.
Sensors 19 00699 g005
Figure 6. Experimental resistance variations monitored by the DIC in Figure 2a when over the chair we had: (a) subjects of different weight and age in the sitting posture P2; (b) objects of different weight. The test was carried out at fs = 60 Sa/s with C = 2.2 µF.
Figure 6. Experimental resistance variations monitored by the DIC in Figure 2a when over the chair we had: (a) subjects of different weight and age in the sitting posture P2; (b) objects of different weight. The test was carried out at fs = 60 Sa/s with C = 2.2 µF.
Sensors 19 00699 g006
Figure 7. Small-signal resistance variations monitored by the DIC in Figure 2a for different sampling frequencies. The test was carried with subject S3 in the sitting posture P2, with C = 1 µF.
Figure 7. Small-signal resistance variations monitored by the DIC in Figure 2a for different sampling frequencies. The test was carried with subject S3 in the sitting posture P2, with C = 1 µF.
Sensors 19 00699 g007
Figure 8. Small-signal resistance variations monitored by the DIC in Figure 2a for different values of the capacitor. The test was carried with subject S2 in the sitting posture P2, with fs = 20 Sa/s.
Figure 8. Small-signal resistance variations monitored by the DIC in Figure 2a for different values of the capacitor. The test was carried with subject S2 in the sitting posture P2, with fs = 20 Sa/s.
Sensors 19 00699 g008
Figure 9. Small-signal resistance variations monitored by the DIC in Figure 2a for different sitting postures (see Figure 5). The test was carried with subject S2 at fs = 20 Sa/s and with C = 1 µF.
Figure 9. Small-signal resistance variations monitored by the DIC in Figure 2a for different sitting postures (see Figure 5). The test was carried with subject S2 at fs = 20 Sa/s and with C = 1 µF.
Sensors 19 00699 g009
Figure 10. Experimental resistance variations monitored by the DIC in Figure 3 when over the chair we had: (a) subjects of different weight and age in the sitting posture P2; (b) objects of different weight. The test was carried out at fs = 2 Sa/s with C = 470 nF.
Figure 10. Experimental resistance variations monitored by the DIC in Figure 3 when over the chair we had: (a) subjects of different weight and age in the sitting posture P2; (b) objects of different weight. The test was carried out at fs = 2 Sa/s with C = 470 nF.
Sensors 19 00699 g010
Figure 11. Small-signal resistance variations monitored by the DIC in Figure 3 for different sitting postures (see Figure 5). The test was carried with subject S2 at fs = 2 Sa/s and with C = 470 nF.
Figure 11. Small-signal resistance variations monitored by the DIC in Figure 3 for different sitting postures (see Figure 5). The test was carried with subject S2 at fs = 2 Sa/s and with C = 470 nF.
Sensors 19 00699 g011

Share and Cite

MDPI and ACS Style

Sifuentes, E.; Gonzalez-Landaeta, R.; Cota-Ruiz, J.; Reverter, F. Seat Occupancy Detection Based on a Low-Power Microcontroller and a Single FSR. Sensors 2019, 19, 699. https://doi.org/10.3390/s19030699

AMA Style

Sifuentes E, Gonzalez-Landaeta R, Cota-Ruiz J, Reverter F. Seat Occupancy Detection Based on a Low-Power Microcontroller and a Single FSR. Sensors. 2019; 19(3):699. https://doi.org/10.3390/s19030699

Chicago/Turabian Style

Sifuentes, Ernesto, Rafael Gonzalez-Landaeta, Juan Cota-Ruiz, and Ferran Reverter. 2019. "Seat Occupancy Detection Based on a Low-Power Microcontroller and a Single FSR" Sensors 19, no. 3: 699. https://doi.org/10.3390/s19030699

APA Style

Sifuentes, E., Gonzalez-Landaeta, R., Cota-Ruiz, J., & Reverter, F. (2019). Seat Occupancy Detection Based on a Low-Power Microcontroller and a Single FSR. Sensors, 19(3), 699. https://doi.org/10.3390/s19030699

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop