Next Article in Journal
Comparative Analysis of Robustness and Tracking Efficiency of Maximum Power Point in Photovoltaic Generators, Using Estimation of the Maximum Power Point Resistance by Irradiance Measurement Processing
Next Article in Special Issue
Pain and Stress Detection Using Wearable Sensors and Devices—A Review
Previous Article in Journal
Performance Evaluation of Knitted and Stitched Textile Strain Sensors
Previous Article in Special Issue
Genetic Deep Convolutional Autoencoder Applied for Generative Continuous Arterial Blood Pressure via Photoplethysmography
 
 
Article
Peer-Review Record

Automatic Classification of Myocardial Infarction Using Spline Representation of Single-Lead Derived Vectorcardiography

Sensors 2020, 20(24), 7246; https://doi.org/10.3390/s20247246
by Yu-Hung Chuang, Chia-Ling Huang, Wen-Whei Chang * and Jen-Tzung Chien
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Sensors 2020, 20(24), 7246; https://doi.org/10.3390/s20247246
Submission received: 18 November 2020 / Revised: 13 December 2020 / Accepted: 14 December 2020 / Published: 17 December 2020
(This article belongs to the Special Issue Advanced Signal Processing in Wearable Sensors for Health Monitoring)

Round 1

Reviewer 1 Report

The manuscript provided a smart method to detect MI using single-lead derived VCG. This will allow wearable devices to detect abnormalities within ECG and detect MI. The problem is significant and the approach seems sound. The authors may add some statistics and references regarding MI in Introduction. Consultation with a cardiologist is helpful to further analyze the data and find clinical applications. 

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 2 Report

This is an interesting paper which explores the use of machine learning to assess myocardial infraction using single-lead derived VCG. The article is of interest; however I do have several observations which mainly focus on the authors not providing sufficient justification for their approach.

  1. The title should be updated to reflect the methodology used in the paper. This includes avoiding the use of abbreviations.
  2. Line 16-17: Please provide a reference to support the statement, and please provide, if possible, the number of persons who die each year as a result of MI.
  3. The authors provide rationale for the method used in the paper within the introduction (ie. line 53-57).
  4. It would be helpful to end the introduction with a clear aim, objective or hypotheses.
  5. Pre-processing: The authors provide a pre-processing frame to improve the signal extract from raw ECG. It would be helpful for the authors to cite other studies which have used the same pre-processing or highlight if they are novel contributions.
  6. Line 118-119: If 3-lead VCG has been used in the past, please provide citations to the previous research.
  7. Line 126-127: Why would a model which can learn the intra and inter-lead correlations could improve accuracy?
  8. Did the authors consider comparing the performance of the current classification framework to other machine learning algorithms?
  9. For training the model, what were the specific parameters used? Did the authors follow a fine turning process?

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Round 2

Reviewer 2 Report

The authors have addressed my concerns. 

 

This manuscript is a resubmission of an earlier submission. The following is a list of the peer review reports and author responses from that submission.

 