1. Introduction
Activities of Daily Living (ADLs) have been intrinsically associated with healthcare outcomes; for example, a range of studies have demonstrated links between day-to-day activities and cardiorespiratory status [
1,
2,
3], sleep with physical and mental health [
4,
5], and more broadly with disease burden [
6]. Assessing ADL including day-to-day Physical Activity (PA) and sleep patterns over the short- to long-term has traditionally been achieved through using self-reports (e.g., using standardized questionnaires and diaries), which are known to be prone to recall and reporting biases [
7,
8]. Using smartphone apps can potentially be more engaging than paper-based forms, it enables time-stamping participants’ responses, and there is evidence of successful long-term adherence in daily questionnaires even for long periods of time (e.g., over a year) [
9]. Nevertheless, there is an increasing understanding and recent work highlighting the need to be moving beyond smartphone apps and integrate additional technologies to facilitate objective, longitudinal monitoring of ADL towards assessing both physical and mental health [
10,
11].
Advances in sensor design, data acquisition and processing, and smart device connectivities through Bluetooth and other protocols, along with increasing affordability and understanding of the benefits of monitoring one’s physical and mental health, have spurred a boom in the development of wearable health-technology devices [
12]. For a succinct description of the evolution of accelerometer-based methods for PA assessment, we refer the reader to Troiano et al. [
13]. There is an abundance of consumer wearable devices; wrist-worn wearables (smartwatches) have particularly captivated the attention of the public, making it a multi-billion market which is expected to grow further over the next few years [
14]. Wrist-worn accelerometers have shown greater promise in terms of adherence and potential for multiple days’ worth of 24-hour monitoring compared to placing the accelerometers elsewhere, e.g., at the waist or hip [
15]. In most cases, the processing of the recorded data relies on proprietary algorithms which are embedded in the devices to provide estimates of steps, floors climbed, calories consumed, and overall sleep quality, aiming to provide overall health indicators. A key challenge with consumer-grade devices is that they lack standardization and often thorough validation [
12], which is difficult to establish given that the raw data and algorithms are not made available.
Research-grade wrist-worn wearable devices, on the other hand, provide access to the raw data, thus providing researchers with opportunities to develop advanced algorithms, for example, towards the assessment of PA, sleep, and circadian variability characteristics [
4,
16]. Early research-grade accelerometers focused on
activity counts, with different manufacturers using different approaches to record them, and this, in turn, complicated cross-device comparisons [
16]. For an outline of additional challenges with the use of activity counts, we refer to Bai et al. [
17]. Contemporary research-grade wrist-worn wearables are more advanced: they typically provide measurements of three-dimensional acceleration data and often additional modalities such as ambient light and wrist temperature (see [
18,
19,
20] for examples).
There is intense research interest towards developing algorithms that process raw three-dimensional accelerometry data which are typically provided from contemporary research-grade devices, developing custom-based algorithms. In principle, this means that we can achieve cross-device compatibility and demonstrably compare findings with transparent algorithms that are applicable across different brands of wearables and hence standardize measurements in the field of actigraphy. A key challenge when processing raw three-dimensional accelerometry data is the sheer volume and the need to develop some approach to summarize the data to visualize patterns and enable further processing. To appreciate the size of a dataset, it is useful to consider the typical sample rate, which is 10–100 Hz in actigraphy studies [
21]: thus, it can be easily inferred that we can collect 1 TeraByte (TB) of data for a single participant within a few weeks. Then it becomes obvious that researchers may be confronted with many TeraBytes of data for a moderate number of participants when collecting longitudinal actigraphy data.
The first step before analyzing the three-dimensional accelerometry data is typically the application of an algorithmic approach to project the recorded acceleration data onto a single vector, which is easier to process. For convenience, we refer to these algorithmic approaches as
acceleration summary measures in this study. Other studies have used the terms ‘metric’ or ‘activity metric’ instead; however, arguably, this might create some confusion when considering the strict definition in mathematics of a metric, and, therefore, we avoid it here. Intuitively, the acceleration summary measures need to meaningfully summarize the three-dimensional acceleration data in
epochs, which, in actigraphy studies, are usually per-minute assessments [
3,
18,
21]. There is an ongoing debate on the merits of different acceleration summary measures both in terms of their robustness (for example, considering sensor properties and potentially adjusting for temperature changes) and also in terms of their subsequent use to facilitate further accurate inferences of PA-related outcomes [
20,
21,
22].
In practice, we often want to process the three-dimensional acceleration data to provide insights into PA. One of the most frequent measures assessing the extent of PA in lab-based settings is via the computation of Metabolic Equivalent Tasks (METs), which provide a meaningful and practical procedure for expressing the energy cost of physical activities as a multiple of the resting metabolic rate [
1]. Often we use discretized bands of METs to define activity behaviors, where the categorization into (i) sleep, (ii) sedentary PA, (iii) light PA, (iv) moderate PA, and vigorous PA are often used and have been integrated into PA guidelines to promote well-being, including by the World Health Organization (WHO) (
https://www.who.int/initiatives/behealthy/physical-activity, last accessed on 30 June 2022) and other health organizations related to morbidities and mortality [
23]. Given how important and practical this five-level PA categorization is and the inherent link of acceleration with PA, many researchers have proposed algorithmic methods to infer these (or a subset of these) five levels, using the three-dimensional acceleration data. Traditionally, this has been achieved by using acceleration summary measure thresholds [
8,
24,
25] or building statistical machine learning models [
3]. Whereas there is a valid argument to be made for using advanced statistical machine learning models if that approach improves PA categorization estimates substantially over threshold-based methods [
3,
26], there is still value in pursuing threshold-based approaches because they are arguably more generalizable and easier to interpret and also can serve as useful performance benchmarks for more advanced methods [
27].
A further topic of crucial importance which has not been sufficiently carefully studied in the context of actigraphy studies is the use of different sample rates. Indicatively, a large systematic review study aiming to provide practical considerations for actigraphy studies endorsed using the highest sample rate possible, e.g., 90 or 100 Hz [
15]. This recommendation is questionable from a practical perspective because there is an inherent trade-off between the sample rate and data-capture duration. Furthermore, from a general signal-processing perspective and following Nyquist’s theorem [
28], we know that we need to sample the data with at least twice the maximum frequency of interest for the task at hand. Resorting to the default highest sample rate that contemporary research-grade accelerometers provide (typically 100 Hz) may be excessive for practical applications for the purpose of assessing PA and sleep, and it, indeed, drains the memory of the device faster, thus prohibiting the collection of longitudinal data in a single device charge. This can be a considerable practical limitation if we want to design longitudinal actigraphy studies, where it would be advisable to strive to use the lowest sample rate that can provide sufficiently good data for the purposes of a particular study. Surprisingly, hitherto there have been few studies systematically investigating the effect of sample rate upon the further analysis of raw three-dimensional accelerometry data for wrist-worn devices, e.g., for different accelerometer summary measures and for specific tasks such as PA and sleep assessment. Most of the studies investigating the effect of sample rates have focused on activity counts, e.g., [
29]. Clevenger et al. [
30] investigated the effect of two sample rates (30 and 100 Hz) on acceleration and activity counts on both hip- and wrist-worn accelerometers. They found that there were differences between the 100 and 30 Hz activity count data; however, they reported that there were no considerable differences in the acceleration data for the wrist-worn accelerometers and that there was excellent agreement (99%) in the estimated PA categories between the two sample rates. It is noteworthy that their study focused on children between the ages 7.3 and 12.5 years, so it does not automatically transpire that these findings necessarily generalize for adults. A further open question is whether using a lower sample rate (e.g., the lowest that many research-grade accelerometers provide, 10 Hz) would still be sufficiently good for sleep and PA assessment, whilst ensuring that we can maximize the data-capture duration in a single accelerometer charge of a wrist-worn device.
Therefore, the motivation for this study was two-fold: (1) explore acceleration summary measures towards estimating PA and sleep, using interpretable threshold-based approaches; and (2) explore whether we need a very high sample rate in the raw three-dimensional acceleration data to accurately estimate sleep and the PA categories. The second part is guided by our ongoing work aiming to collect many weeks’ worth of data in a single device charge to infer sleep and PA towards monitoring healthcare outcomes, and hence we wanted to explore whether the minimum typical sample rate (10 Hz) is sufficient. The aims of the study are, thus, as follows: (a) introducing a new acceleration summary measure, which is usefully summarizing the raw three-dimensional data; (b) empirically investigating the performance of the new acceleration summary measure, along with three well-established acceleration summary measures towards PA assessment; and (c) comparing performance in PA assessment when using raw accelerometry data sampled at four different sample rates, namely 10, 25, 50 and 100 Hz, to explore the generalizability of the proposed algorithms and establish whether we need the high-resolution data for sleep and PA assessment.
3. Results
Table 1 summarizes the Spearman correlation coefficients of the four acceleration summary measures explored here (ENMONZ, MAD, AI, and ROCAM) with the five PA categories (sleep; sedentary, light, moderate, and vigorous PA). For convenience, we report these correlations for four different versions of the CAPTURE-24 dataset where we have used the raw 100 Hz data and the down-sampled versions (50, 25 and 10 Hz) of the three-dimensional accelerometry data.
We remark that all four acceleration summary measures exhibit statistically strong associations with PA categories (Spearman correlation coefficients well above |0.3|). Therefore, this is a reassuring finding, as it shows that all four measures capture useful information in the raw three-dimensional acceleration data towards estimating the PA categories used herein. ENMONZ is the least correlated acceleration summary measure and ROCAM is consistently the most strongly associated acceleration summary measure with the PA categories.
A further interesting finding in
Table 1 is that the correlations of each of the acceleration summary measures with the PA categories are not drastically affected as a result of using lower-resolution data. ENMONZ exhibits a slightly lower correlation when the accelerometry data are sampled at a low sample rate (10 Hz); however, the other established acceleration summary measures (MAD and AI) appear to be largely unaffected. On the contrary, ROCAM appears to improve somewhat with lower sample rate; this is, perhaps, a counter-intuitive finding, and we revisit it later, in the Discussion.
Figure 2 presents the violin plots of the four acceleration summary measures (ENMONZ, MAD, AI, and ROCAM) for acceleration data sampled at 100, 50, 25 and 10 Hz, respectively. These plots serve to provide a visual overview of the differences in the distributions across the five PA categories within a specific sample rate (focusing on the comparisons within each of the four plots, i.e.,
Figure 2a–d) and also as a function of the sample rate in the accelerometry data (comparing the different acceleration summary measures across the different sample rates). By looking directly at the plots in
Figure 2, we can visually appreciate that the range and distributions of values for all acceleration summary measures are different as a result of using accelerometry data sampled at different sample rates. This intuitively suggests that any thresholds and any statistical learning models developed with data collected when using a particular sample rate would likely not generalize well in a different dataset collected with a different sample rate. In other words, we need to have sample-rate-specific thresholds if we want to operate directly with data sampled at different sample rates.
In the following processing stages for the study, we used the acceleration data when sampled at 10 Hz. This is both because this is the sample rate that led to the overall highest correlation with the five categories (see
Table 1) and because, practically, this is a more generalizable setting, given that we can always down-sample accelerometry data if they were collected at a higher sample rate (whereas we cannot recover information in the higher frequency ranges if we were to up-sample data).
Figure 3 presents the densities for the four acceleration summary measures, where we can obtain a visual illustration of the extent of overlap and intuitively get a feel for possible thresholds we might be exploring to differentiate the five categories. There is considerable overlap across the five categories, particularly between sleep and sedentary, and between light, moderate, and vigorous PA. Visually it is not immediately clear if any of the four acceleration summary measures is superior, although ROCAM arguably has clearer points that we might use to define thresholds to differentiate the categories (e.g., vigorous PA stands out more clearly). We remark that, with such high correlation coefficients (in
Table 1) and the illustrations in
Figure 2 and
Figure 3, we can be quite confident that we should be able to identify the PA categories correctly most of the time by using acceleration summary measure thresholds. Intuitively, these plots also serve to caution us about the differentiation of certain PA categories when using threshold-based methods, for example, where there is substantive overlap in the distributions (e.g., in light and moderate PA).
Table 2 summarizes the optimized thresholds for each of the four acceleration summary measures following the formal optimization process to maximize accuracy, along with their overall accuracy in differentiating the PA categories when using accelerometry data sampled at 10 Hz. For completeness, we also present the optimized thresholds when using data sampled at 25, 50, and 100 Hz in
Supplementary Tables S1–S3, respectively, in the
Supplementary Material. We remark that ROCAM has an edge over the competing acceleration summary measures, with a reported accuracy of 80.8%, thus verifying what we intuitively expected from the findings presented in
Table 1 with the reported correlation coefficients.
A relevant question then is whether this difference in performance between ROCAM and the other acceleration summary measures is statistically significant. We used the two-sample KS test to assess whether the resulting estimates from the different acceleration summary measures are statistically significantly different. In all cases, we found that the results were statistically significantly different (
p < 0.0001), and, combined with the results presented in
Table 2, this indicates that ROCAM indeed offers a statistically significant improvement over its competitors in terms of accurately estimating the PA categories.
Figure 4 shows the confusion matrix for ROCAM that was used towards estimating the PA categories by using the optimized thresholds reported in
Table 2. On the right-hand side, we also present the percentage of correctly vs. incorrectly matched labels for each of the five PA categories, as this serves to identify areas of potential improvement more easily (in combination with the actual entries off the main diagonal in the confusion matrix). For example, it is clear that sleep and sedentary activity are very accurately detected and there is space for improving the estimation of light and moderate activity; in particular, the ‘moderate PA’ is often mistakenly estimated as ‘light PA’. For comparison with the ROCAM findings presented in
Figure 4, we also present the confusion matrices for ENMONZ, MAD, and AI in
Supplementary Figures S1–S3. We note that there are some fairly substantive differences in the estimation of different PA categories amongst the different threshold-based methods for the acceleration summary measures. For example, ROCAM is particularly powerful in correctly identifying sleep, sedentary activity, and vigorous PA compared to ENMONZ, MAD, and AI, whereas all of these three competing methods are better at estimating light PA compared to ROCAM. These differences in the accuracy of estimating particular PA activities could implicitly suggest that some sort of combination or voting using all four acceleration summary measures and/or the estimated PA categories might lead to better results and, hence, motivates the following step.
In an attempt to explore improving these findings, we used RF developing statistical learning models. Specifically, we (i) computed the estimated outputs for the five categories when applying the optimized thresholds for each of the four acceleration summary measures independently, and then we presented these outputs to an RF; and (ii, iii) combined the two steps presented above, presenting them jointly as inputs into an RF.
Figure 5 presents the confusion matrix of the trained RF (model where the estimated PA outputs followed the application of the optimized thresholds): we observed that there is further improvement in overall accuracy (82.2%) that mainly comes from improving the estimates for the ‘light’ and ‘moderate’ PA categories. However, this comes at the cost of some reduction in the estimation accuracy of sedentary and vigorous PA. We remark that the results of the RF models built either with the use of the acceleration summary measures directly, or with the use of jointly the acceleration summary measures along with the PA estimates following the threshold application were similar to the RF model built using the PA estimates following the optimized threshold application. Therefore, we opted to present the approach that is computationally simplest.
4. Discussion
We investigated four acceleration summary measures (three widely used and the new ROCAM proposed here) across four different sample rates (100, 50, 25 and 10 Hz) to process three-dimensional acceleration data collected from the wrist in order to construct a 24-hour physical-activity-and-sleep-profile assessment. The study has made a number of key contributions. First, we have demonstrated that the widely used and practically default approach to summarize three-dimensional accelerometry data in actigraphy (ENMONZ) is likely not the best method to summarize the raw data, at least not towards the differential assessment of sleep and the standard PA categorization (sedentary, light, moderate, and vigorous PA), as reported in
Table 1 and
Table 2. Second, the new acceleration summary measure, ROCAM, appears to be a very competitive method, particularly towards the differentiation of sleep and PA, with the additional advantage that it is very robust with reduced sample rate (in fact, the association strength of ROCAM with the five categories is practically optimized with data sampled at 10 Hz). Third, we have shown that different sample rates for the three-dimensional accelerometry data can have a considerable effect in terms of the range in the acceleration summary measure values (see
Figure 2) and, to a lesser extent, to the resulting statistical association with PA categories (
Table 1); this has important implications for carefully considering how to use reported thresholds and built models across studies with different sample rates. Fourth, sampling the three-dimensional acceleration data at 10 Hz is fully sufficient for the purpose of differential assessment of sleep and PA, at least when it comes to using threshold approaches to estimate the five PA categories explored in this study. Fifth, by using ROCAM and appropriately optimized thresholds, we can obtain 80.8% accuracy in differentiating the PA categories; we can improve accuracy by considering all four acceleration summary measures and presenting them in an RF to obtain 82.2% accuracy in correctly matching the PA categories. We would especially like to highlight the very accurate detection of sleep and sedentary activity from using simple thresholds for ROCAM (see
Figure 4), which has important implications in understanding ADL and their association with healthcare outcomes [
4].
ENMONZ is an intuitively appealing acceleration summary measure which builds on the standard concept of Euclidean distance. This explains why it is practically the default option in actigraphy packages (such as GGIR) and its widespread use, including in the study that reported on the CAPTURE-24 data [
31] and many other studies in the research literature [
3,
33,
44]. However, the findings presented in this study challenge the status quo and the widespread use of ENMONZ. We have reported (see
Table 1) that ENMONZ is the acceleration summary measure which has the lesser association strength with the five PA categories amongst the four acceleration summary measures investigated. Moreover, ENMONZ was the only one of the four acceleration summary measures that has a statistical association with the five categories that degrades considerably with data sampled at 10 Hz. This is not a problem in itself, necessarily, if an acceleration summary performs very well, say at 100 Hz, and degrades considerably when presented with low-resolution data; however, it is an indicator that, particularly with acceleration data sampled at low sample rates, one should be cautious when using ENMONZ. Particularly given that ENMONZ is not better associated with the PA categories at the higher sample rates, there is good evidence presented here to suggest that competing acceleration summary measures should be strongly considered for PA categorization and likely also for other actigraphy data-processing tasks. We reported that there is a small but clear performance improvement of 2% (which is also statistically significant) when using ROCAM over ENMONZ; this is noteworthy, given that this is a challenging five-class problem. The developers of MAD and AI had previously compared their findings to ENMONZ [
21,
22]; however, those comparisons were limited from using shorter-period laboratory-based data compared to the 24-hour data collected under free living conditions explored in this study. Therefore, the comparisons of the four acceleration summary measures (ENMONZ, MAD, AI, and ROCAM) reported here are novel in terms of the data-collection environment (non-controlled) and duration of collection, which, in principle, should better reflect the generalizability of the presented findings in other free-living longitudinal actigraphy studies.
Perhaps counter-intuitively, ROCAM appears to be more strongly associated with the five categories when using lower-resolution acceleration data (sampled at 10 Hz), as can be seen in
Table 1. This likely reflects the instantaneous nature of the ROCAM algorithm, as it takes successive differences across each of the three axes, and, hence, it might be that operating at very high granularity (e.g., with the 100 Hz sampled data) might reflect changes in internal accelerometer noise. Therefore, this empirical finding likely suggests that ROCAM might be overly sensitive to very high-resolution data, and it is
advantageous to down-sample the data at least for the purpose of estimating the five categories used herein. It will be interesting to see if this finding can be generalized for other settings where the actual labels in a problem are different (for example, trying to directly estimate different activities, as explored in Willetts et al. [
33]).
Previous work has reported findings and provided acceleration summary measure thresholds or models to assess PA when using high-sampled acceleration data, e.g., 80 Hz [
22] and 100 Hz [
31,
33], as this limits applicability in new datasets that do not use the same high sample rates since these thresholds and models are sample-rate dependent. Arguably, in most practical applications in community studies, we do not need a sample rate beyond 25 Hz for a general-purpose assessment of PA because typically people do not move their hands beyond a few times per second (at least in the sense of what we would be interested to assess in most research studies for PA). By Nyquist’s theorem [
28], we should be aiming to sample at about twice the maximum frequency of interest in the data; therefore, a sample rate of 100 Hz would probably be considered excessive for research purposes focusing on the general population for longitudinal PA assessment. Given that there is usually a trade-off to be made between the use of the sample rate and the duration of the data collected (indicatively, Geneactiv can collect up to 7 days of data at 100 Hz and about 60 days of data at 10 Hz in a single charge; Axivity AX3 has a maximum logging period of 30 days at 12.5 Hz or 14 days at 100 Hz) and that many research studies often aim to provide longitudinal outcome assessments, a pragmatic practical decision would be to use 10 Hz to maximize data collection duration, whilst retaining meaningful signal variability on per-second basis. For these reasons, and to ensure that the provided algorithms developed herein are generalizable and deployable in studies planning to focus on longer-term monitoring, we wanted, in particular, to assess the use of three-dimensional data sampled at 10 Hz. The implication is that it is easy to down-sample accelerometry datasets which were collected by using a higher sample rate and directly use the methodology and the thresholds described in this study. On the contrary, a research study which used a sample rate of 10 Hz would not be able to benefit from guidelines and recommended thresholds and models developed if these require high-sample-rate data.
The differences in performance for accelerometry data sampled at different sample rates can be appreciated by comparing the results presented in
Table 2 and the
Supplementary Tables S1–S3, which present findings with data sampled at 25, 50, and 100 Hz, respectively. We note that, as expected from the correlation coefficient results reported in
Table 1, the accuracy of obtaining the PA categories with appropriately optimized thresholds was best when using data sampled at 10 Hz, using ROCAM. A careful comparison of these tables also reveals important differences in the optimized thresholds when using acceleration data sampled at different sample rates for all the acceleration summary measures, a finding which is not unexpected when considering the probability distributions presented in
Figure 2. This serves to highlight the importance of carefully considering the choice of sample rate on generalizing findings towards PA assessment. Overall, on the basis of the current evidence in this study, it appears that using three-dimensional accelerometry data sampled at 10 Hz is fully sufficient for the purposes of the differential assessment of PA categories explored here.
It is difficult to directly compare side-by-side the accuracy reported here with findings in the research literature, in part because some works use different PA categories, exclude sleep assessment (e.g., focusing on shorter time intervals rather than 24-hour profile assessment), or focus on lab-based recordings where very specific tasks are followed under controlled conditions to calculate METs. Walmsley et al. [
3] were the first to use CAPTURE-24 data to assess different categories, similarly to this study, towards 24-hour profile assessment, and they reported a 87.7% accuracy. They used four categories (sleep, sedentary PA, light PA, and MVPA); that is, compared to this study, they had combined moderate and vigorous PAs into a single category (since there are relatively few samples in vigorous PA in the CAPTURE-24 dataset, and they wanted to use a balanced dataset for training the RF). They had retained the originally sampled 100 Hz data and had trained a complicated RF to estimate the four categories when presented with 50 advanced features extracted from the raw accelerometry data by applying a range of signal processing algorithms. This is a compelling approach: in practice, we can develop and apply different algorithms to characterize the accelerometry data and subsequently select a robust parsimonious feature subset (e.g., using feature selection or feature transformation methods [
45,
46]) which is presented to the statistical learner. Compared to Walmsley et al., we remark that the approach explored here is (a) generalizable across different sample rates and, in particular, can be run in emerging actigraphy datasets sampled at 10 Hz that we and others are currently collecting, thus practically enabling longer data collection on a single smartwatch charge compared to higher sample rates (we will be reporting on these findings in future follow-up work); (b) computationally much faster, since it does not involve the computation of many advanced features that are presented to a statistical learner (and potentially also involving additional steps in the statistical learning process such as feature selection or feature transformation); (c) differentiates between moderate and vigorous PA, as such a distinction is clinically important for certain applications and overall WHO recommendations regarding weekly exercise. We also stress that the use of threshold-based methods intrinsically avoids the well-known problem of supervised statistical learning setups when training on highly unbalanced datasets where the dominant class(es) will typically be the output of the classifier. Hence, in this study, we did not need to explicitly account for creating balanced subsets as in Walmsley et al. [
3]. Instead, with threshold-based methods, we can control for potential clear dominance of classes by carefully setting the lower- and upper-boundaries in the constrained optimization algorithm where we compute the thresholds (in this study, these were set following visual inspection of the probability distributions; see
Figure 3). In the results not shown in this study, we found that the resulting complicated trained RF of Walmsley et al. [
3] does not generalize well in datasets sampled at different sample rates (i.e., when down-sampling the CAPTURE-24 data at 25 Hz or in new datasets we are currently in the process of collecting, sampled at 10 Hz). Intuitively, this could be explained by the differences we noted in the acceleration summary distributions reported when using acceleration data sampled at different sample rates (see
Figure 2). Therefore, the requirement of having data sampled at 100 Hz to use their trained statistical leaning model is practically very restrictive for actigraphy studies aiming to collect longitudinal data.
From a practical perspective, the approach proposed here, with the use of acceleration summary thresholds, needs to be further improved in terms of correctly assessing light and moderate PA, which are conflated with sedentary and light PA, respectively (see
Figure 4 and
Figure 5). There is clear room for improvement, for example, by deploying some postprocessing approach, possibly invoking dynamic programming concepts or some other method that takes into account the actual time-state changes to more accurately follow the trajectory of the five categories for each participant. This is an area that we intend to build on further in future work. We note that other threshold-based PA categorization studies had similarly reported challenges in distinguishing between certain categories, for example, between sedentary and light PA and/or overestimating MVPA [
25,
44].
We note that the CAPTURE-24 is the largest known freely available accelerometry-based dataset with detailed minute-by-minute labels, where data have been collected under real-world conditions rather than in highly controlled lab settings. This makes it an ideal dataset upon which to develop and validate an algorithmic framework towards assessing 24-hour activity profiles, with the vision that the lessons learned can be translated to similar large-scale community studies. For example, the developers of CAPTURE-24 have used the learnings from their algorithmic framework in CAPTURE-24 and PA assessments to provide new insights into the UK BioBank study analyzing weekly actigraphy data from more than 85,000 participants [
3]. The provided labels in the form of METs in CAPTURE-24 were estimated by reviewing photos and diaries rather than being directly measured, and therefore it is possible that the developed algorithms might need to be further refined with additional datasets where lab-based METs measurements are available. Nevertheless, for the purposes of obtaining an overall PA categorization (including sleep) and 24-hour profile assessment under non-controlled lab conditions, the CAPTURE-24 dataset is a particularly useful resource.
The study has a number of limitations which we acknowledge. Although CAPTURE-24 is the largest publicly available actigraphy database in free living conditions
with detailed labels, findings ideally need to be explored and validated on a larger cohort or additional external datasets. In particular, it would be useful to have cohorts with different pathologies, since algorithms developed when processing actigraphy data in healthy controls do not necessarily generalize well in regard to people with certain pathologies, e.g., sleep-related pathologies [
18]. We focused on four acceleration summary measures (ENMONZ, MAD, AI, and ROCAM), motivated by the use of the first three computational approaches which have been widely used in similar reports, and proposing the new acceleration summary measure ROCAM. There are other acceleration summary measures which have been proposed in the research literature which have not been explored here due to space and practicality constraints and the fact they had not shown any tangible advantages over the acceleration summary measures reported here (see [
20], for example). Furthermore, there are some devices (and also legacy datasets and legacy algorithms) operating on ‘activity counts’, often focusing on mono-axial accelerometers (i.e., single-axis acceleration), where a popular acceleration summary measure is zero crossing (ZC). There is existing work to align recent developments in three-dimensional acceleration processing and count-based or ZC algorithms to enable backwards compatibility [
47], and these approaches and acceleration summary measures were not investigated herein because, arguably, they offer a more crude measure of activity compared to sensors, which provide raw three-dimensional acceleration signals. The methods proposed herein were validated on participants wearing the accelerometer on their dominant hand; cutoffs to assess PA levels are likely dependent on device placement (dominant or non-dominant hand; see [
15,
48]), and, hence, future work should carefully consider how well the findings can be generalized. Moreover, the findings presented in this study are for
wrist-worn acceleration data; although the methodology presented should, in principle, be applicable to other body placements, specific detailed thresholds and findings reported herein would be different for acceleration data recorded elsewhere (e.g., on the hip), as previous work has shown [
15,
24,
49]. Finally, we did not consider age-, gender-, and motor-competence-specific analyses due to the relatively limited sample size to perform these detailed stratifications: there is some work that suggests that these affect accelerometer outputs, calling for more personalized threshold-based methods [
50,
51].