Article

Towards Cognitive Authentication for Smart Healthcare Applications

by
Ali Hassan Sodhro
1,2,*,
Charlotte Sennersten
1 and
Awais Ahmad
3
1
Department of Computer Science, Kristianstad University, 291 88 Kristianstad, Sweden
2
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518000, China
3
Department of Computer and System Science, Mid Sweden University, 831 25 Ostersund, Sweden
*
Author to whom correspondence should be addressed.
Sensors 2022, 22(6), 2101; https://doi.org/10.3390/s22062101
Submission received: 13 January 2022 / Revised: 2 March 2022 / Accepted: 4 March 2022 / Published: 9 March 2022

Abstract

:
Secure and reliable sensing plays the key role for cognitive tracking i.e., activity identification and cognitive monitoring of every individual. Over the last years there has been an increasing interest from both academia and industry in cognitive authentication also known as biometric recognition. These are an effect of individuals’ biological and physiological traits. Among various traditional biometric and physiological features, we include cognitive/brainwaves via electroencephalogram (EEG) which function as a unique performance indicator due to its reliable, flexible, and unique trait resulting in why it is hard for an un-authorized entity(ies) to breach the boundaries by stealing or mimicking them. Conventional security and privacy techniques in the medical domain are not the potential candidates to simultaneously provide both security and energy efficiency. Therefore, state-of-the art biometrics methods (i.e., machine learning, deep learning, etc.) their applications with novel solutions are investigated and recommended. The experimental setup considers EEG data analysis and interpretation of BCI. The key purpose of this setup is to reduce the number of electrodes and hence the computational power of the Random Forest (RF) classifier while testing EEG data. The performance of the random forest classifier was based on EEG datasets for 20 subjects. We found that the total number of occurred events revealed 96.1% precision in terms of chosen events.

1. Introduction

The key goal of the cognitive authentication is to identify, trace and track individual differences of biological signatures, behavioral features such as facial expressions, fingerprints, voice, eye movements, gestures, and postures, etc. [1,2]. At present numerous emerging strategies related to the biometric authentication are being integrated and evolved in interdisciplinary domains i.e., personal identification, access and assets monitoring applications. Among biometric-based technologies it is witnessed that EEG signals gathered during behavioral and/or mental activity can be adopted for reliable authentication and identification [3]. On one hand EEG enabled systems are contributing into the human identity monitoring field, while at the same time we are facing various critical challenges such as security, accuracy, privacy, and robustness, etc. To fix these concerns it is very vital to develop innovative and secure methods to protect and secure the individual privacy [4]. The Human Computer Interface (HCI) is playing a catalyst role while displaying stimuli (visual or auditory) and capturing signals recognizing the personal identity trait. There are still large research gaps regarding security, privacy and energy efficiency. Resolving emerging problems and trends in association with strong ties of Brain Computer Interface (BCI) such as virtual headsets and internet are key parameters in personal authentication and recognition [5,6].
Traditionally security methods are not up to scratch and effective when looking at simple legalization and identity monitoring issues. So, to cope with these problems an EEG based physiological system is a suitable candidate for the upcoming next generation systems [7,8] due brainwaves reflect/mimic the human mode and actions performed. The secure, prominent and malware detection capabilities of brainwaves make EEG i.e., brainwaves unique and attentive for many fields especially wireless networks, various industries, and academia. Few decades ago, some researchers worked and addressed the emerging role and importance of brain signals while identifying and monitoring the activity of the individual entities [9]. Biological features are key since long time and emphasized by researchers and academics [10]. Brainwaves are related to the neurons of the human showing various brain activity in regular and random ways [11]. Due brainwaves’ strong connection and association with mental tasks, their states are hard to interpret, copy and hijack from external source if used as passwords. Moreover, EEG signals are interlinked with someone’s thoughts, knowledge, and memory which makes it hard for someone to exploit, steal and replicate [12,13]. EEG reflects and contains the information from human neurons via small, more effective, and lightweight devices [14,15,16]. To fulfill and meet the demands of public citizens it is to provide a highly secure and energy efficient protective, flexible, scalable, unique, and stable biometric system to compensate for the drawbacks of current conventional platforms [17,18]. However, EEG performance suffers in some fields due to noise, interference, and compatibility issues. EEG enabled systems still need higher maturity and improvement in high-level security, comfort, and ease to end users. Therefore, it is very important to propose a novel, and unique EEG enabled biometric platform for real time or near real time healthcare applications. This paper reviews, addresses current trends and practices in the field of EEG based biometric systems and discusses the key merits, demerits with a recommended tentative future solution.
Authentication is considered as the key part in computer platform security, and this prevents access by hackers and illegal users. In addition, the process is to match or check the similarity and coherence between stored and obtained data. In an agreement condition, a person or a computer is potentially allowed to access the system else prohibited. It is important to have the accurate authentication rights to access the system. The result of a non-secure system is information privacy leakage and breaches which will further result harming the customer. Today’s most powerful authentication systems have password protection and identity monitoring. Users make themselves recognizable via words/passwords, but this let alone is not enough to fully identify and protect personal information. The traditional password protection is lacking in cognitive uniqueness therefore anyone can steal and hack it. To advance a poor password and keep it secure the user needs to increase the complexity-level which will be very hard to memorize. To progress and replace current orthodox security techniques, it is suitable to introduce and address the notion of biometric authentication. Tangible features as fingerprints, voice and facial expressions are hard to be compromised and stolen by attackers and intruders. Thanks to tangible brain readings recorded via EEG, it creates strong unique identity traits hard to replicate. It is observed and analyzed that other physiological features such as Electrocardiography (ECG) is easy to attack and exploit.
The main contribution of this paper is to present an extensive review about a secure, reliable cognitive/EEG-based authentication system for the IoT-driven healthcare applications as revealed in Table 1. The paper analyses 20 subjects’ EEG datasets imported from the Physionet bank ATM database and validates the performance of the proposed framework in terms of performance indicators via accuracy, precision, true positive (TP) rate and precision with the help of the Random Forest (RF) classifier as shown in Table 2. In addition, this research focuses on EEG-based biometric systems, their advantages, limitations, applications, and to propose a novel framework approach.
The paper is organized as follows. Section 2 presents an extensive review of current work, further in Section 3 a secure and reliable cognitive/EEG-based authentication system is presented. Section 4 proposes the novel framework for the same system. Methods of the system are addressed in Section 5. Detailed applications of are explored in Section 6. After in Section 7 tentative solutions and recommendations are presented. EEG data collection and experimental setup is presented in Section 8. Last in Section 9 a conclusion of the paper.

2. Existing Work

In the following section, several papers by various researchers are listed and compared in relation to focus and respective traits with the aim to provide a secure solution for public. With respect for all individual efforts there is still room for innovative solutions using EEG. Some of the relevant research contributions are listed, what focus and crosschecked in Table 1 below.
First part of this extensive survey presented the security and privacy related techniques, solutions, and challenges, while the second part was mainly concerned with the biometric enabled systems and their comparisons to the traditional platforms, limitations, and advantages. Thirdly, proposes the tentative solutions, and recommendations.

3. Deficiencies in Authentication Methods in IoT-Based Healthcare Applications

Current traditional human physiological features are not satisfying the needs for several domains i.e., medical hospitals, industrial platforms, and academia. In comparison to the traditional password authentication process, the biometric tracking is more feasible and unique with its physiological features. The output from the human body parts result in reduced efforts memorizing extra passwords and security codes. The biometric input tracking from human is given below:
  • Fingerprint scans: Scans and maps fingers.
  • Handprint scan: Tracks and scans the entire pattern of the hand.
  • Voice identification: Recording human voice signals and traits.
Some important steps must be taken into consideration though while introducing the concept of real-time applications.
For a system of this kind, it needs some common prerequisites to perform to meet individual unique needs;
  • Universal: Monitoring the identity of the system-users we need biological traits to minimize the chances of information leakage.
  • Uniqueness: To differentiate every human physiological feature from others to achieve an accurate error free result.
  • Stability: There should be less variation and more accurate outcome.
  • Flexibility: Adaptive and scalable in nature regarding the physiological features. As a result, it will be hard decoding and leaking the secret information.
  • Acceptability: Important is to get individual consent for tracking and storage due private nature.
  • Durability: Biological features are harder to replicate and this way also more sustainable dealing with security issues.
As we have already said EEG based authentication is widely adopted, precise, secure, and broadly accepted in the Security domain. The EEG activity mirrors different modes such as anger, happiness, crying, sadness, etc. Every single trait is unique therefore has a separate impact on entire individual signature performance. Mental activity and performed actions are replicated and mirrored in the EEG and works as signifiers during data analysis. These mental tasks have close and strong ties with the produced EEG patterns which serve to be more secure, and this way keep away a common intruder or un-authorized entity. Hence, in this situation it can be said that EEG based biometric is the two-step authentication and integration process. There are several other fields where EEG has remarkably played the major role in providing the security and innovative practices, that is why EEG based features outperforms the others. Most importantly, EEG or brainwaves are related to the human neurons so when these are active and functioning properly than several signals and information types can be exchanged. In other words, we can say that EEG is a more prominent communication pattern identifier unlike other biological signals.
In case of emergency, injuries, and other accident issues the biometric pattern(s) can be affected and people are in this case not allowed to attend personal authentication until their injuries are healed. One hazard and limitation, fingerprints can still be performed in a state of dizziness and inactive mode. If fingerprints are cross checked with the EEG signal though it is still hard to be hijacked and leaked. EEG based techniques in comparison to fingerprint authentication is facing a critical challenge of Gaussian noise which can affect sensitive healthcare information. This means we must be aware of both pros and cons from embodied electrodes/leads.

4. Proposed Framework of Cognitive Authentication System

We would like to propose a novel cognitive authentication framework comparing various core concepts of privacy and security provisioning shown in Figure 1. This cognitive authentication framework of cognitive/EEG signals are processed, extracted and classified by adopting machine and deep learning based on adaptive methods. After human computer interaction (HCI) is established the feedback from HCI via the original EEG signal plays a significant role when managing and monitoring the brain wave authentication. Our proposed framework is most simple, efficient, and secure for the medical healthcare sector applications facilitating the patients and physicians at an economical rate. We aim to develop a prototype of brain wave monitoring under strict security assurance. The key characteristic of the proposed framework follows. To limit complexity a dynamic self-identity management mechanism i.e., biometric system can be developed merely with the EEG signals. From previous research results we realize there is no mature nor practical biometric system of self-adaptive nature character i.e., security and energy optimal. In this regard, it is vital to have an EEG-based cognitive ideal authentication system allocating parameters in an efficient and authenticated way.

4.1. Simple and Efficient

It is observed and analyzed from previous research studies that high performance can be achieved from a well deployed and secure system [15,16,17,18,19], while with a more computational complex task(s) system a threshold is met due to more resources e.g., time consumption and longer delay. The authentication, balances between individual entities on one hand which on the other hand affects other parts of the system.

4.2. Channels and Electrodes

Numerous types of EEG headsets are adopted for exact and accurate measurements to provide high level security in both clinical and academic contexts. It is proved that as the number of leads/channels are increasing than higher and better accuracy will be achieved [11]. With high accuracy there are less chances of information hack and eavesdropping. A strong presence of security level is a prioritization. A simple and less probes-based EEG system takes less computational power and results in compromised security, that is why not a potential candidate [15,16,17,18,19,20]. Researchers [21,22,23,24,25], propose wet EEG electrodes for high signal accuracy, calibration and less noise, interference unlike the dry leads.

4.3. Data Collection Pattern

Large data sets enhance the accuracy of the adopted algorithms. Researchers in [12] examine the voluminous datasets into single and multi-patterns. Authors in [14] examine categorization of different subjects based on different factors for example, maximum number of participants, accuracy of the system and outcome. Systems with data from few subjects are not robust. Researchers in [20] present data gathering tools based on several subjects with their unique features and problem-solving traits.

4.4. Computational Cost

Computational cost is related to several techniques and parameters such as number of electrodes, thinking responses, heartbeat fluctuations, behavior analysis, and neural and fuzzy based machine learning methods, etc. Integration of classified traits extend and promote accuracy levels even if longer delays.

4.5. Stability

Cognitive/EEG or human brain waves are dynamic and well pattern-based mechanism with adaptive nature. In addition, the action and activities are revealed according to priorities and choices of humans towards training [23] of their mind. Most of the time real-time data sets are helping to identify the behaviors and ties in terms of his/her consistency and attitude [25]. In the long run data sets are not suitable candidates analyzing an entire behavior of a human. Live human actions in combination with mental tasks are more promising and relevant fully incorporating the desired tasks.

4.6. Flexibility

Traditional biometric based systems are hard to change due to their close association with the human biological features unlike the password-protection based on secure and authenticated attributes. In the present era, EEG enabled biometrics has created huge attention worldwide according to the advancements of capturing human brainwaves and mental task readings [11].

5. Methods for Cognitive Authentication System

There are several methods for security and privacy preserving data and information but biometrics is the best suited method to deal with the vulnerability problems. Here we present some of the techniques providing efficient methods.

5.1. Machine Learning

Self-adaptive and intelligent techniques are the key ingredients to revolutionize the digital world without the intervention of the external features and resources. The machine learning (ML) driven techniques are highly dependent on the datasets by analyzing and examining the critical challenges for instance, linear regression, hierarchical, and clustering etc for the clear understanding of desired target. So, this sub-section highlights the importance of intelligent techniques in portraying the clear characteristics of EEG to evaluate the disease type. After careful examination and importance of the self-driven mechanism ML is separated into following keys methods.
Supervised learning: In this method tags are assigned to specific data types by classifying main groups/category(ies). Besides, data patterns are extracted based on preliminary data models by properly guiding the future techniques.
Unsupervised Learning: There is no particular label to the clustered data sets due to the self-learning learning nature of the data-driven model. In addition, data patterns are recognized based on previous gained knowledge.
Reinforced Learning: The key characteristics of this data model is to communicate with external entities by collecting and enhancing the knowledge. Then a reward or penalty will be assigned based on the action (i.e., success/failure) taken accordingly. Furthermore, data models are trained and analyzed by adopting two intelligent sub-areas such as, support vector machine (SVM) and deep learning (DL). Both SVM and DL follows the supervised learning strategy to further improve the performance of entire system. In last, this learning mechanism helps the brain to analyze the EEG behavior in a better, self-adaptive and effective way.
For further understanding the clustering and classification challenges in data models such as SVM is considered as the key role player. Data sets are spread and adopted in multi-dimensional areas with number of rows and columns. While this paper considers the EEG as an evolutionary mechanism for understanding the human brain activity. SVM is involved to build hyper-planes and by classifying and categorizing the data/data models, the hyper-plane is very vital to compose the desired datasets. In the bunch of data sets one hyper-plane is enough to lead the entire group. Wise selections of hyper-planes give better options to play with datasets managing, monitoring, and classifying them into intendable and interpretable platform outcomes. Furthermore, hyper-planes are the key ingredient to deal with the datasets in this intelligent data world.

5.2. Deep Learning and Neural Network

Deep learning (DL) lies under the umbrella of machine learning, and it is used to model accurate and efficient modelling of random and abstract data content(s). The DL adopts less computational steps to complete a task with short time span unlike traditional ML methods, so it is preferred in most research. DL foundations are also key steps toward an artificial human nervous system integrated with robotics and self-driven fields. Besides, a multi-layer hierarchy is adopted in the entire system with its input from previous layer as output of the next coming one, this will continue up to the intended outcome with minimum error. All the interconnected layers exchange the information among each other and other associated entities at lower and higher levels through the specific functional units, neurons. Most of the interconnected entities i.e., neurons function by adapting vital procedural parameters from well-known DL models for instance, deep neural networks (DNN), convolutional neural networks (CNN), and recursive neural networks (RNN). In this research DNN is considered as the game changer and potential candidate to tackle the entire process in EEG monitoring, clustering, and management.
Our targeted DNN platform comprises input, output, and hidden layers to form the long lasting and collaborative hierarchical network for data exchange with specific processing units and task allotment. Each layer is characterized with the number of nodes to fulfill the criteria of the network by properly designing the entire platform with slightly more deviation in the hidden layer format with distinct features. In addition, a hidden layer plays the major role in analysing the computationally complex process of several inputs and outputs.

5.3. Self-Adaptive and Dynamic Resource Allocation

Using the methodology of neural network and fuzzy logic the resources such as, battery lifetime and power can be allotted to medical devices in a fair and intelligent way. Security is the major challenge for EEG devices, power and battery lifetime results in less storage space for these devices.
In this regard compressive sensing is the potential candidate in most of the traditional platforms, but still there are several limitations while dealing with EEG based biometric environment. So, to remedy most of the issues chaotic compressive sensing is a suitable option.

6. Applications of Cognitive Authentication System

There are various applications of EEG-based cognitive authentication systems, some widely scoped and discussed one by one below.

6.1. Medical Healthcare

Pervasive nature of mobile devices in healthcare domain face hard challenges while securing the sensitive information between various entities from patients to physicians and from medical clouds to hospitals. In other words, we can say that there is a need of novel EEG based biometric techniques to fix both the energy efficiency and security issues.

6.2. Industrial Enterprises

In today’s emerging era of the forth industrial revolution, Industry 4.0, there is a need of highly demanded security and authentication methods to deal with the security and management issues of voluminous data from different industries. If customers are not getting proper security while buying any product it will be hard to gain their trust. Thus, product owners must guarantee valuable security and efficient methods.

6.3. Access Control and Personal Identity Management

Personal security and identity monitoring is the first and foremost priority of everyone signing any contract, agreement, or bond with anyone, anywhere. Without proper trust and belief one cannot assign, handover his/her property at risk. Specially, in the healthcare domain it is very vital to respect and protect patient’s secret and sensitive data and keep it away from any harm. Hence, it is important to propose novel access control for personal data/information management.

7. Advantages, Limitations, Tentative Solutions and Recommendations

This section presents the novel tentative solutions with potential recommendations for solving the security issues in most of the areas especially medical information communication technology (MICT) for healthcare.
EEG-based cognitive systems with biological features are key players in selecting a suitable protocol to monitor and identify the identity of individuals for the better and strong security levels. Noise and interference occurs between neurons while adopted for human identity recognition due to separated and unique roles for each biological trait in the biometric system. Moreover, collected random neurons are associated with the mental tasks and superimposed behavior of other similar functional brainwave signals in speeding up the entire process. Physiological features such as eye movements, hear-rate, blood circulation are a little bit different from the EEG signals. The huge and bulky load of brain responses, the interference and noise levels are relatively low while recording the EEG signals. Thus, some careful and efficient steps must be taken to remedy most of the unwanted noise in the very sensitive information throughout the system. The main beauty of the EEG based signals for biometrics is that there is slightly less noise and artifacts [42]. The downside of EEG enabled biometrics is that the security level is less reliable when low-cost hardware devices are adopted. These security challenges are part of practical issues in the healthcare domain [11].
EEG based systems are not new, also widely portrayed in various domains since long time. Some key problems faced while deploying such system, there are no direct off the shelf suitable tools and software, second, more computational complexity, and delay in transmitting/exchanging information to intended users.

7.1. Advantages of Cognitive Authentication System

Emerging trends and rapid proliferation in the technological EEG-driven cognitive authentication systems era emit every living being unique brain pulses for stimulating the visual and auditory sections. EEG maps the signal of brain activity related to either (1) screen stimuli or (2) thought process. If gaze is used in addition to a thought process, then we can add these screen coordinates as an additional authenticator for security reasons. If a person looks at a stimulus it generates both an EEG signal via the electrodes and also a gaze pattern via gaze tracking. The latter shows what a person is looking at on the screen while the EEG signal indicates a COS/SIN curve which does not reveal anything of gazed location on the screen nor the gazed content. The abstract thought processes of thinking, emotions, dreams, perceptions, feelings, levels of happiness and sadness all impact on the outcome of mental process generating unique EEG patterns accordingly. In an event-triggered situation, the critical brain waves will show different responses in comparison to a normal situation. These various patterns are hard to crack if anonymous to the intruder. Moreover, EEG based security methods are more robust to handle hacking and eavesdropping as compared to conventional methods. In case of illegal and forceful authentication by intruders and attackers, the security level will not be compromised. Therefore, it can be said that other less secure and ineffective methods are easy to be interpreted and compromised and not reliable and sustainable entities in a security provisioning domain [8]. In other words, it can be said that EEG signals are built-in, or by-default featured for high level security and are hard to comprise as compared to other technologies [6]. Due to simple, effective ways, they are hard to decode. These technologies revolutionize the biometric platform era with high end security patterns in combination.

7.2. Limitations of Cognitive Authentication System

The EEG signal capturing devices are low power oriented which is not a limitation itself. Pre-processing is more sensitive to handle due fast paced feedback responses happening in a few microseconds. Most of the current technologies are leads/electrodes integrated for calculating the EEG signals with non-invasive nature. However, the responses recorded by an electrode varies to a large extent even if its position deviates by a minuscule pattern [29]. Electrodes must be implanted in a careful, exact, and proper manner while providing high authentication for a system. Consistency between EEG signals before and after examination is important to take under consideration [30].
Subjects with both physiological and mental conditions and their data readings must be synchronized to meet a sustainable and stable accurate baseline performance maintaining high security level. The captured brainwaves reveal the mental task via continuous measurements. This means any slight change in mood or mental state will be reflected during measurements. To prevent and to create a calibrated baseline, it is required to keep a steady mental state prior EEG recording.
Therefore, it is preferred to put individuals in rest mode by closing their eyes and turn-off all unwanted sources to provide high level efficiency for collecting the accurate and desirable EEG signals. This way we can get eliminate data noise and disturbances.

7.3. Recommended Solutions

7.3.1. Solution1: Chaotic Compressive Sensing Enabled Authentication Scheme

A chaotic random captured mental process is hard to interpret. A more secure mechanism is sought for. The simple non-random data generation technique is more promising to build a matrix for a strong security platform [43]. In addition, this procedure forms a unique matrix by well-defined and clear steps. Most popular example of a chaotic process is the chebyshev chaotic filters [50,51,52,53] for further data generation operation.
The principle of this solution is based on the generation of a particular matrix encrypting the information, then transmitted over the wireless channel and finally decoded at the receiver side i.e., edge computing embodying higher security measures. The main advantages are to occupy less storage space, security and energy efficiency in the medical healthcare applications, as shown in Figure 2.
Efficient and voluminous storage space reduction are main traits of the compressive sensing providing a secure and energy efficient system in the healthcare environment [25]. Small size nodes communicate among themselves and neighboring nodes with help of intermediate routers i.e., relays up to shorter distance. Those relay nodes are necessary exchanging information between themselves (from-to), but it is not necessary to interpret and decrypt the messages from any outside device/relay. Only an authorized entity is allowed to decrypt/decode the message from a transmitting entity. Based on that message sharing capability using a sender-receiver pair, a measurement matrix will be generated to avoid information leakage and eavesdropping.

7.3.2. Solution 2: Fuzzy-Vault Based Authentication Scheme

A random key is generated in a dynamic way unlike the traditional methods, so it is robust and accurate. This optimizes the resources in an efficient and autonomous way and will be widely used in the Bluetooth low energy domain including internet of medical things-based applications, as presented in Figure 3.

7.3.3. Solution 3: Adaptive and Random Key Generation Mechanism

This solution can be effective and sufficient for the emerging mobile healthcare applications such as, Low Range (LoRa). The key mechanism of this approach is to generate the master key, which is eXclusive OR (XORed) with the certificate from a third trusted party. After receiving a certificate and a master key then an initial key will be produced protecting the entire system by adaptively adjusting the keys, as revealed in Figure 4.

8. Experimental Setup

To demonstrate the EEG based authentication method an experiment has been conducted to be able to showcase how we practically design, set up and use these measurements. Below are required steps including chosen datasets, events, classifiers, and results from these.

8.1. A. EEG Data Sets

We obtained EEG motor movement/imagery datasets from one of the largest and widely used databases called Physionet [112,113,114]. The selected datasets comprise 2 min indivudal EEG recordings of 109 subjects using the European Data Format (EDF) web browser. The data contains 64 scalp electrodes while performing a few tasks shown in the Table 2 below. In this experiment we considered only 20 subjects (s1, s2, to s20) out of total 109 data recordings.
One of the EEG subject scenario procedures are asking subjects to perform two actions at the same time i.e., reinforced activity consisting of opening and closing their right and left hand physically and at the same time mimicing the movements mentally. After this activity the subjects are asked to relax so baseline can be met.

8.2. B. Event Extraction

The recordings are in a comma-seperated-values (CSV) format containing Motor movement/imagery EEG data obtained from Physionetbank ATM and further analyzed via the European Data Format (EDF) browser. The main purpose to choose the EDF browser to obtain annotations and events during the experiments with temporailty, including start and total time of entire experiment. The chosen datasets carry three annotations which are time 0, time 1, and time 2 [T0, T1, T2] measuring the performance by included subjects. Notice all time related actions are performed as indiviudal isolated tasks. Further detail of the annotations are given as:
  • T0 shows either (1) the event where the subject is in entire rest position or (2) performing any imagined motor movement task.
  • The T1 event reveals the subject’s left-hand movement while performing either a physical or mental task.
  • T2 is mainly reserved for observing subject’s right-hand movement either physically or mentally.

8.3. C. Classification

The EDF browser is used to achieve annotations for output labels so it is possible to run the classifiers; T0, T1, and T2 for each subject. For each classifier we have 64 electrode data points involved for effective and accurate classification as shown in Table 2.
The effective classification result is using the Random Forest method creating decision trees from training datasets in a random fashion [112,113,114]. The selection of an individual decision tree and different decision trees are the main decision factors of a final class of an object under test. The Random Forest classifier is adopted in our experimental setup because it is efficient and gives accurate estimation and classification with multi-inputs by large datasets.

8.4. D. Results and Discussion

The weighted mean of all included classes for each of the 20 subjects by considering the Random Forest Classifier for measuring the performance in terms of four main performance indicators for instance, accuracy, precision, true positive rate (TPR) and ROC area is presented in Table 2.
Precision: The small fraction of related events from the total number of occurred events in the experimental setup defines the precision. Suppose precision for S4 is 0.961, which reveals that 96.1% of chosen events are identical or related to each other as presented in Table 2.
True Positive (TP) Rate: The small number of positively corrected instances from total positive events gives the status of TP rate. One of the examples in Table 2 highlights the TP rate for S10 is 0.994 which means that events are classified with correction upto 99.4%.
Area Under Curve (AUC): For accuracy measurement of classifiers AUC is the appropriate indicator for test verfication, so higher the AUC means the better the test is. For instance, If AUC is 1, it means test of classifier is good and effective, while 0.5 shows poor or ineffective test. Table 2 shows the AUC value less than 0.7 for some subjects, and greater than 0.6 for most of the subjects. It is observed that test does not fail (less than 0.5) for any subject in our experiment which means Random Forest classifier is the potential candidate with better accuracy for 20 subjects.
Working through the cognitive authentication method and reviewing prior works, it is realized that any possible weaknesses such as possible falsification of data and/or online hijacking must be highlighted. Any data type, and number of features and signatures can be hard to replicate/mimic as previously said but even an inserted malware could possibly crack individual features over time. So, there must be potential solution for cognitive authentication with strong protective wall/firewall. In near future study we will run a cognitive authentication and try to hijack the authenticator/intruder with and without using firewall to check how long it takes to breach the security and reveal the identity. In other words, it can be safer if we connect cognitive authentication with two-factor authentication for strong security measure.

9. Conclusions and Future Research

This paper broadly presented the state-of-the art solutions and recommendations to fix the security and privacy problems by proposing the novel EEG-driven secure and reliable cognitive authentication system for a IoT-based healthcare system. An EEG-based cognitive authentication framework is proposed. Most remarkable and prominent EEG enabled biometric platforms are explored and addressed by both researchers and academics from practical aspects. It is analyzed and predicted from the broader scope and outcome of the EEG-driven biometric system that this can be adopted as a guide and trend setting solution for the next generation systems. It can be emphasized that future biometric environments must be developed in such a way that EEG channels/leads, algorithms, and signal processing techniques have strong ties with high level of coordination. By keeping in view, the demand of the healthcare in today’s world it is investigated that the energy optimization and security of nodes during information exchange are critical factors.
The key purpose of our experimental setup is to reduce the number of electrodes and hence the computational power of Random Forest classifier while testing EEG data. MATLAB is adopted for analysis and measuring the performance of the random forest classifier by testing EEG datasets of 20 subjects. We found that the RF classifier outperforms by revealing accurate and effective results, thus can be recommended for future similar scenarios and applications.
Hence, our future research will focus on the chaotic compressive sensing and self-adaptive i.e., machine learning strategies for the betterment of both security and power allotment in a fair way. In addition, the hardware, and the software platform for the chaotic compressive sensing for the e-Healthcare applications will be developed.

Author Contributions

A.H.S., written the abstract, Introduction, related work, compiled results, addressed proposed solutions, and finally concluded the entire article. C.S. reviewed, reformulated, and improved the English text. A.A. formatted the references, collected data and written challenges. All authors have read and agreed to the published version of the manuscript.

Funding

This work is financially supported by the Research grant of PIFI 2020 (2020VBC0002), China.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Datsets from one of the online database, available online: https://physionet.org/ (accessed on 13 January 2022).

Conflicts of Interest

The authors declare that there is no conflict of interest.

References

  1. Vadlamudi, G.A.; Kishan, K.H. Security Authentication using Brain Waves. In Proceedings of the 2021 7th International Conference on Advanced Computing and Communication Systems (ICACCS), Coimbatore, India, 19–20 March 2021; pp. 104–107. [Google Scholar]
  2. Damaševičius, R.; Maskeliūnas, R.; Kazanavičius, E. Combining Cryptography with EEG Biometrics. Comput. Intell. Neurosci. 2018, 2018, 1867548. [Google Scholar] [CrossRef] [Green Version]
  3. Alruwaili, F.F. Artificial Intelligence and Multi Agent Based Distributed Ledger System for Better Privacy and Security of Electronic Healthcare Records. PeerJ Comput. Sci. 2020, 6, e323. [Google Scholar] [CrossRef] [PubMed]
  4. Hathaliya, J.J.; Tanwar, S. An Exhaustive Survey on Security and Privacy Issues in Healthcare 4.0. Comput. Commun. 2020, 153, 311–335. [Google Scholar] [CrossRef]
  5. Mahendran, R.K.; Velusamy, P. A Secure Fuzzy Extractor Based Biometric Key Authentication Scheme for Body Sensor Network in Internet of Medical Things. Comput. Commun. 2020, 153, 545–552. [Google Scholar] [CrossRef]
  6. Alladi, T.; Chamola, V. A Two-Way Authentication Protocol for Three Entity Healthcare IoT Networks. IEEE J. Sel. Areas Commun. 2020, 39, 361–369. [Google Scholar] [CrossRef]
  7. Al-Janabi, S.; Al-Shourbaji, I.; Shojafar, M.; Shamshirband, S. Survey of main challenges (security and privacy) in wireless body area networks for healthcare applications. Egypt. Informat. J. 2016, 18, 113–122. Available online: http://www.sciencedirect.com/science/article/pii/S1110866516300482 (accessed on 13 January 2022). [CrossRef] [Green Version]
  8. Liu, X.; Zhu, Y.; Ge, Y.; Wu, D.; Zou, B. A secure medical information management system for wireless body area networks. KSII Trans. Internet Inf. Syst. 2016, 10, 221–237. [Google Scholar]
  9. Sun, S.; Xing, J.; Zhou, Z.; Wang, W.; Chen, J. Comparative Study of Compressed Sensing for Heart Sound Acquisition in Wireless Body Sensor Networks. IEEE Access 2020, 8, 22483–22492. [Google Scholar] [CrossRef]
  10. Dautov, R.; Tsouri, G.R. Securing while sampling in wireless body area networks with application to electrocardiography. IEEE J. Biomed. Health Informat. 2016, 20, 135–142. [Google Scholar] [CrossRef]
  11. Pareschi, F.; Albertini, P.; Frattini, G.; Mangia, M.; Rovatti, R.; Setti, G. Hardware-algorithms co-design and implementation of an analogtoinformation converter for biosignals based on compressed sensing. IEEE Trans. Biomed. Circuits Syst. 2016, 10, 149–162. [Google Scholar] [CrossRef]
  12. Autthasan, P.; Du, X.; Arnin, J.; Lamyai, S.; Perera, M.; Itthipuripat, S.; Wilaiprasitporn, T. A Single-Channel Consumer-Grade EEG Device for Brain–Computer Interface: Enhancing Detection of SSVEP and Its Amplitude Modulation. IEEE Sens. J. 2019, 20, 3366–3378. [Google Scholar] [CrossRef] [Green Version]
  13. Chatterjee, R.; Maitra, T.; Islam, S.H.; Hassan, M.M.; Alamri, A.; Fortino, G. A Novel Machine Learning Based Feature Selection for Motor Imagery EEG Signal Classification in Internet of Medical Things Environment. Future Gener. Comput. Syst. 2019, 98, 419–434. [Google Scholar] [CrossRef]
  14. Anguraj, D.K.; Smys, S. Trust-Based Intrusion Detection and Clustering Approach for Wireless Body Area Networks. Wirel. Pers. Commun. 2019, 104, 1–20. [Google Scholar] [CrossRef]
  15. Bohr, A.; Memarzadeh, K. The Rise of Artificial Intelligence in Healthcare Applications. In Artificial Intelligence in Healthcare; Elsevier: Amsterdam, The Netherlands, 2020; pp. 25–60. [Google Scholar]
  16. Sodhro, A.H.; Guizani, M.; Boukerche, A. AI-Enabled Reliable Channel Modelling Architecture for FoG Computing Vehicular Networks. IEEE Wirel. Commun. Mag. 2020, 27, 14–21. [Google Scholar] [CrossRef]
  17. Alsunaidi, S.J.; Saqib, N.A.; Alissa, K.A. A comparison of human brainwaves-based biometric authentication systems. Int. J. Biom. 2020, 12, 411–429. [Google Scholar]
  18. Yousefi, F.; Baker, T. SaS-BCI: A new strategy to predict image memorability and use mental imagery as a brain-based biometric authentication. Neural Comput. Appl. 2021, 33, 4283–4297. [Google Scholar] [CrossRef]
  19. Sodhro, A.H.; Li, Y.; Shah, M.A. Novel Key Storage and Management Solution for the Security of Wireless Sensor Networks. TELKOMNIKA Indones. J. Electr. Eng. 2013, 11, 3383–3390. [Google Scholar] [CrossRef]
  20. Boubakeur, M.R. Self-Relative Evaluation Framework for EEG-Based Biometric Systems. Sensors 2021, 21, 2097. [Google Scholar] [CrossRef]
  21. Schiliro, F.; Moustafa, N.; Beheshti, A. Cognitive Privacy: AI-enabled Privacy using EEG Signals in the Internet of Things. In Proceedings of the 2020 IEEE 6th International Conference on Dependability in Sensor, Cloud and Big Data Systems and Application (DependSys), Nadi, Fiji, 14–16 December 2020; pp. 73–79. [Google Scholar]
  22. Zahid, N.; Sodhro, A.H.; Kamboh, U.R.; Alkhayyat, A.; Wang, L. AI-driven adaptive reliable and sustainable approach for Internet of Things enabled healthcare system. Math. Biosci. Eng. 2022, 19, 3953–3971. [Google Scholar] [CrossRef]
  23. Mattar, E.A.; Al-Junaid, H.J.; Al-Mutib, K.N. Electroencephalography Features Extraction and Deep Patterns Analysis for Robotics Learning and Control through Brain-Computer Interface. In Proceedings of the 2019 International Conference on Innovation and Intelligence for Informatics, Computing, and Technolo-gies (3ICT), Sakhier, Bahrain, 22–23 September 2019; pp. 1–6. [Google Scholar] [CrossRef]
  24. Das, R.; Maiorana, E.; Campisi, P. Motor Imagery for EEG Biometrics Using Convolutional Neural Network. In Proceedings of the 2018 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Calgary, AB, Canada, 15–20 April 2018; pp. 2062–2066. [Google Scholar] [CrossRef]
  25. Faisal, T.; Benatchba, K.; Koudil, M. Matching Similarity Scores for a Minutiae-based Palmprint Recognition. In Proceedings of the IECON 2019—45th Annual Conference of the IEEE Industrial Electronics Society, Lisbon, Portugal, 14–17 October 2019; pp. 132–137. [Google Scholar] [CrossRef]
  26. Abe, N.; Yamada, S. A Novel Quality Assessment Method for Eye Movement Authentication. In Proceedings of the 2020 Asia-Pacific Signal and Information Processing Association Annual Summit and Conference (APSIPA ASC), Auckland, New Zealand, 7–10 December 2020; pp. 1430–1435. [Google Scholar]
  27. Lodro, M.M.; Majeed, N. Statistical channel modelling of 5G mmWave MIMO wireless communication. In Proceedings of the 2018, International Conference on Computing, Mathematics and Engineering Technologies (iCoMET), Sukkur, Pakistan, 3–4 March 2018; pp. 1–5. [Google Scholar]
  28. Murtazina, M.S.; Avdeenko, T.V. Classification of Brain Activity Patterns Using Machine Learning Based on EEG Data. In Proceedings of the 2020 1st International Conference Problems of Informatics, Electronics, and Radio Engineering (PIERE), Novosibirsk, Russia, 10–11 December 2020; pp. 219–224. [Google Scholar] [CrossRef]
  29. Sodhro, A.H.; Pirbhulal, S.; Muhammad, K. Towards 6G Architecture for Energy Efficient Communication in IoT-Enabled Smart Automation Systems. IEEE Internet Things J. 2021, 8, 5141–5146. [Google Scholar] [CrossRef]
  30. Aggarwal, S.; Chugh, N. A decade of EEG Analysis: Prospects & Challenges in Biometric System. In Proceedings of the 2020 10th IEEE International Conference on Cloud Computing, Data Science & Engineering Confluence, Noida, India, 29–31 January 2020; pp. 474–479. [Google Scholar]
  31. Seha, S.N.A.; Hatzinakos, D. EEG-based human recognition using steady-state AEPs and subject-unique spatial filters. IEEE Trans. Inf. Forensics Secur. 2020, 15, 3901–3910. [Google Scholar] [CrossRef]
  32. Sodhro, A.H.; Pirbhulal, S. Artificial Intelligence Driven Mechanism for Edge Computing based Industrial Applications. IEEE Trans. Ind. Inform. 2019, 15, 4235–4243. [Google Scholar] [CrossRef]
  33. Zahid, N.; Sodhro, A.H.; Janjua, M.B.; Chachar, F.A.; Sodhro, G.H.; Abro, S.A.K. HARQ with chase-combining for bandwidth-efficient communication in MIMO wireless networks. In Proceedings of the International Conference on Computing, Mathematics and Engineering Technologies (iCoMET), Sukkur, Pakistan, 3–4 March 2018; pp. 1–6. [Google Scholar]
  34. Armstrong, B.C.; Ruiz-Blondet, M.V.; Khalifian, N.; Kurtz, K.J.; Jin, Z.; Laszlo, S. Brainprint: Assessing the uniqueness, collectability, and permanence of a novel method for ERP biometrics. Neurocomputing 2015, 166, 59–67. [Google Scholar] [CrossRef]
  35. Maiorana, E.; la Rocca, D.; Campisi, P. On the permanence of EEG signals for biometric recognition. IEEE Trans. Inf. Forensics Secur. 2016, 11, 163–175. [Google Scholar] [CrossRef]
  36. Chen, Y.; Atnafu, A.D.; Schlattner, I. A highsecurity EEG-based login system with RSVP stimuli and dry electrodes. IEEE Trans. Inf. Forensics Secur. 2016, 11, 2635–2647. [Google Scholar] [CrossRef]
  37. Kaveh, R.; Doong, J.; Zhou, A.; Schwendeman, C.; Gopalan, K.; Burghardt, F.L.; Muller, R. Wireless User-Generic Ear EEG. IEEE Trans. Biomed. Circuits Syst. 2020, 14, 727–737. [Google Scholar] [CrossRef]
  38. Sodhro, A.H.; Li, Y.; Shah, M.A. Energy-efficient Adaptive Transmission Power Control in Wireless Body Area Networks. IET Commun. 2016, 10, 81–90. [Google Scholar] [CrossRef]
  39. Rasool, R.U.; Ahmad, H.F. Security and Privacy of Internet of Medical Things: A Contemporary Review in the Age of Surveillance, Botnets, and Adversarial ML. J. Netw. Comput. Appl. 2022, 201, 103332. [Google Scholar] [CrossRef]
  40. Nakamura, T.; Goverdovsky, V.; Morrell, M.J.; Mandic, D.P. Automatic sleep monitoring using ear-EEG. IEEE J. Transl. Eng. Health Med. 2017, 5, 2800108. [Google Scholar] [CrossRef]
  41. Sodhro, A.H.; Zahid, N. AI-Enabled Framework for Fog Computing Driven E-Healthcare Applications. Sensors 2021, 21, 8039. [Google Scholar] [CrossRef]
  42. Masud, M.; Gaba, G.S.; Choudhary, K. A Robust and Lightweight Secure Access Scheme for Cloud Based E-Healthcare Services. Peer-Peer Netw. Appl. 2021, 14, 3043–3057. [Google Scholar] [CrossRef] [PubMed]
  43. Rahman, M.A.; Hossain, M.S.; Showail, A.J. A Secure, Private, and Explainable IoHT Framework to Support Sustainable Health Monitoring in a Smart City. Sustain. Cities Soc. 2021, 72, 103083. [Google Scholar] [CrossRef]
  44. Goverdovsky, V.; Looney, D.; Kidmose, P.; Mandic, D.P. In-ear EEG from viscoelastic generic earpieces: Robust and unobtrusive 24/7 monitoring. IEEE Sens. J. 2016, 16, 271–277. [Google Scholar] [CrossRef]
  45. Dayo, Z.A.; Cao, Q. A Compact High-Gain Coplanar Waveguide-Fed Antenna for Military RADAR Applications. Int. J. Antennas Propag. 2020, 2020, 8024101. [Google Scholar] [CrossRef]
  46. Sodhro, A.H.; Sangaiah, A.K.; Sodhro, G.H.; Lohano, S.; Pirbhulal, S. An Energy-Efficient Algorithm for Wearable Electrocardiogram Signal Processing in Ubiquitous Healthcare Applications. Sensors 2018, 8, 923. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  47. Spyrou, L.; Kouchaki, S.; Sanei, S. Multiview classification and dimensionality reduction of scalp and intracranial EEG data through tensor factorisation. J. Signal Process. Syst. 2018, 90, 273–284. [Google Scholar] [CrossRef] [Green Version]
  48. Wang, X.W.; Nie, D.; Lu, B.L. Emotional state classification from EEG data using machine learning approach. Neurocomputing 2014, 129, 94–106. [Google Scholar] [CrossRef]
  49. Zhang, Y.; Huang, T.; Bompard, E.F. Big data analytics in smart grids: A review. Energy Inform. 2018, 1, 8. [Google Scholar] [CrossRef]
  50. Muzammal, M.; Talat, R. A Multi-Sensor Data Fusion Enabled Ensemble Approach for Medical Data from Body Sensor Networks, Information Fusion; Elsevier: Amsterdam, The Netherlands, 2020; Volume 53, pp. 155–164. [Google Scholar]
  51. Portillo-Lara, R.; Tahirbegi, B. State-of-the-Art Technologies and Applications for EEG-Based Brain–Computer Interfaces. APL Bioeng. 2021, 5, 031507. [Google Scholar] [CrossRef]
  52. Hammadi, A.I.; Yeun, C.Y. Explainable Artificial Intelligence to Evaluate Industrial Internal Security Using EEG Signals in IoT Framework. Ad Hoc Netw. 2021, 123, 102641. [Google Scholar] [CrossRef]
  53. Jain, H.; Chamola, V. 5G Network Slice for Digital Real-Time Healthcare System Powered by Network Data Analytics. Internet Things Cyber-Phys. Syst. 2021, 1, 14–21. [Google Scholar] [CrossRef]
  54. Tang, X.; Li, W.; Li, X.; Ma, W.; Dang, X. Motor imagery EEG recognition based on conditional optimization empirical mode decomposition and multi-scale convolutional neural network. Expert Syst. Appl. 2020, 149, 113285. [Google Scholar] [CrossRef]
  55. Liang, H.; Maedono, S. Exploring Neuro-feedback Training for BMI Power Augmentation of Upper Limbs: A Pilot Study. Entropy 2021, 23, 443. [Google Scholar] [CrossRef] [PubMed]
  56. Binnewijzend, M.A.A.; Adriaanse, S.M.; Van der Flier, W.M.; Teunissen, C.E.; De Munck, J.C.; Stam, C.J.; Wink, A.M. Brain network alterations in alzheimer’s disease measured by eigenvector centrality in fMRI are related to cognition and CSF biomarkers. Hum. Brain Mapp. 2014, 35, 2383–2393. [Google Scholar] [CrossRef] [PubMed]
  57. Illman, M.; Laaksonen, K.; Liljeström, M.; Jousmäki, V.; Piitulainen, H.; Forss, N. Comparing MEG and EEG in detecting the~ 20-Hz rhythm modulation to tactile and proprioceptive stimulation. NeuroImage 2020, 215, 116804. [Google Scholar] [CrossRef]
  58. Sodhro, A.H.; Pirbhulal, S. Green Media-Aware Medical IoT System, Multimedia Tools & Applications; Springer: Berlin/Heidelberg, Germany, 2018; pp. 1–20. Available online: https://link.springer.com/article/10.1007/s11042-018-5634-0 (accessed on 13 January 2022).
  59. Sreedevi, A.G.; Harshitha, T.N.; Sugumaran, V.; Shankar, P. Application of Cognitive Computing in Healthcare, Cybersecurity, Big Data and IoT: A Literature Review. Inf. Process. Manag. 2022, 59, 102888. [Google Scholar] [CrossRef]
  60. Šumak, B.; Brdnik, S.; Pušnik, M. Sensors and Artificial Intelligence Methods and Algorithms for Human–Computer Intelligent Interaction: A Systematic Mapping Study. Sensors 2022, 22, 20. [Google Scholar] [CrossRef]
  61. Giler-Velásquez, G.; Marcillo-Delgado, B.; Vaca-Cardenas, M.; Vaca-Cardenas, L. Software Frameworks That Improve HCI Focused on Cognitive Cities. A Systematic Literature Review. In Proceedings of the International Conference on Advanced Research in Technologies, Information, Innovation and Sustainability, La Libertad, Ecuador, 25–27 November 2021; Springer: Berlin/Heidelberg, Germany, 2021; pp. 142–157. [Google Scholar]
  62. Agbeyibor, R.; Butts, J.; Grimaila, M.; Mills, R. Evaluation of format-preserving encryption algorithms for critical infrastructure protection. In Proceedings of the International Conference on Critical Infrastructure Protection, Arlington, VA, USA, 17–19 March 2014; Butts, J., Shenoi, S., Eds.; Springer: Berlin/Heidelberg, Germany, 2014; Volume 441, pp. 245–261. [Google Scholar]
  63. Ahmad, A.; Mozelius, P.; Ahlin, K. Speech and Language Relearning for Stroke Patients- Understanding User Needs for Technology Enhancement. In Proceedings of the eTELEMED 2021, The Thirteenth International Conference on eHealth, Telemedicine, and Social Medicine, Nice, France, 18–22 July 2021. [Google Scholar]
  64. Higo, H.; Isshiki, T.; Mori, K. Privacy-preserving fingerprint authentication resistant to hill-climbing attacks. In SAC 2015; LNCS; Dunkelman, O., Keliher, L., Eds.; Springer: Cham, Switzerland, 2016; Volume 9566, pp. 44–64. [Google Scholar] [CrossRef]
  65. Dinh, T.; Steinfeld, R. A lattice-based approach to privacy-preserving biometric authentication without relying on trusted third parties. In Proceedings of the International Conference on Information Security Practice and Experience, Melbourne, Australia, 13–15 December 2017; Springer: Cham, Switzerland, 2017; pp. 297–319. [Google Scholar]
  66. Sodhro, A.H.; Pirbhulal, S.; Gurtov, A.; Wang, L. Towards 5G-enabled Self Adaptive Green and Reliable Communication in Intelligent Transportation System. IEEE Trans. Intell. Transp. Syst. (T-ITS) 2021, 22, 5223–5231. [Google Scholar] [CrossRef]
  67. Sedenka, J.; Govindarajan, S.; Gasti, P.; Balagani, K.S. Secure out-sourced biometric authentication with performance evaluation on smartphones. IEEE Trans. Inf. Forensics Secur. 2015, 10, 384–396. [Google Scholar] [CrossRef]
  68. Shahandashti, S.F.; Safavi-Naini, R.; Ogunbona, P. Private fingerprint matching. In ACISP LNCSS; Usilo, W., Mu, Y., Seberry, J., Eds.; Springer: Berlin/Heidelberg, Germany, 2012; Volume 7372, pp. 426–433. [Google Scholar] [CrossRef]
  69. Khalid, S.S. Application of Fingerprint-Matching Algorithm in Smart Gun Using Touch-Less Fingerprint Recognition System. In Applications of Artificial Intelligence in Electrical Engineering; IGI Global: Hershey, PA, USA, 2020; pp. 122–128. [Google Scholar]
  70. Bos, J.W.; Lauter, K.; Loftus, J.; Naehrig, M. Improved security for a ring-based fully homomorphic encryption scheme. In IMACC 2013; LNCS; Stam, M., Ed.; Springer: Berlin/Heidelberg, Germany, 2013; Volume 8308, pp. 45–64. [Google Scholar] [CrossRef]
  71. Wu, W.; Liu, J.; Wang, H.; Hao, J.; Xian, M. Secure and efficient outsourced k-means clustering using fully homomorphic encryption with ciphertext packing technique. IEEE Trans. Knowl. Data Eng. 2020, 33, 3424–3437. [Google Scholar] [CrossRef]
  72. Yousuf, H.; Lahzi, M.; Salloum, S.A.; Shaalan, K. Systematic review on fully homomorphic encryption scheme and its application. Recent Adv. Intell. Syst. Smart Appl. 2021, 295, 537–551. [Google Scholar]
  73. Sodhro, A.H.; Pirbhulal, S. A Joint Transmission Power Control and Duty-Cycle Approach for Smart Healthcare System. IEEE Sens. J. 2019, 19, 8479–8486. [Google Scholar] [CrossRef] [Green Version]
  74. Duong, D.H.; Mishra, P.K. Efficient secure matrix multiplication over LWE-based homomorphic encryption. Tatra Mt. Math. Publ. 2016, 67, 69–83. [Google Scholar] [CrossRef] [Green Version]
  75. Cao, N.; Wang, C.; Li, M.; Ren, K.; Lou, W. Privacy-preserving multi-keyword ranked search over encrypted cloud data. IEEE Trans. Parallel Distrib. Syst. 2014, 25, 222–233. [Google Scholar] [CrossRef] [Green Version]
  76. Ahmadi, A.; Sodhro, A.H.; Cherifi, C.; Cheutet, V.; Ouzrout, Y. Evolution of 3C Cyber-Physical Systems Architecture for Industry 4.0. In International Workshop on Service Orientation in Holonic and Multi-Agent Manufacturing; Springer: Cham, Switzerland, 2018; pp. 448–459. [Google Scholar]
  77. Che, X.; Zhou, T.; Li, N.; Zhou, H. Modified multi-key fully homomorphic encryption based on NTRU cryptosystem without key-switching. Tsinghua Sci. Technol. 2020, 25, 564–578. [Google Scholar] [CrossRef]
  78. Hu, D.; Lovell, N.H.; Nguyen, H.T.; Fotiadis, D.I.; Dokos, S.; Feng, D.D. Decomposing Atrial Activity Signal by Combining ICA and WABS. In Proceedings of the 35th IEEE Annual International Conference of the Engineering in Medicine and Biology (EMBC), Osaka, Japan, 3–7 July 2013. [Google Scholar]
  79. Fu, Z.; Sun, X.; Liu, Q. Achieving efficient cloud search services: Multi-keyword ranked search over encrypted cloud data supporting parallel computing. IEICE Trans. Commun. 2015, 98, 190–200. [Google Scholar] [CrossRef]
  80. Xia, Z.; Wang, X.; Sun, X. A secure and dynamic multi-keyword ranked search scheme over encrypted cloud data. IEEE Trans. Parallel Distrib. Syst. 2016, 27, 340–352. [Google Scholar] [CrossRef]
  81. Xu, J.; Chang, E.C.; Zhou, J. A New Functional Encryption for MULTIDIMENSIONAL Range Query. Cryptology ePrint Archive. 2017. Available online: http://eprint.iacr.org/2017/970 (accessed on 13 January 2022).
  82. Sodhro, A.H.; Obaidat, M.S.; Gurtov, A. Towards Wearable Sensing Technology Enabled Healthcare Framework for Elderly Patients. In Proceedings of the 54th IEEE International Conference on Communications (ICC) 2020, Dublin, Ireland, 7–11 July 2020. [Google Scholar]
  83. Garg, S.; Gentry, C.; Halevi, S.; Zhandry, M. Functional encryption without obfuscation. In TCC 2016; LNCSK; Ushilevitz, E., Malkin, T., Eds.; Springer: Berlin/Heidelberg, Germany, 2016; Volume 9563, pp. 480–511. [Google Scholar] [CrossRef]
  84. Yun, K.; Xue, R. Chosen Ciphertext Attacks Secure Inner-Product Functional Encryption from Learning with Errors Assumption. In Proceedings of the Information Security and Cryptology: 16th International Conference, Inscrypt 2020, Guangzhou, China, 11–14 December 2020; Springer: Berlin/Heidelberg, Germany, 2021; pp. 133–147. [Google Scholar]
  85. Chen, L.; Lu, D. Development of knowledge-based ontology framework for diabetes patients in medical applications. In Proceedings of the BIBE 2018 International Conference on Biological Information and Biomedical Engineering, Taichung, Taiwan, 29–31 October 2018; pp. 1–4. [Google Scholar]
  86. Attrapadung, N.; Hanaoka, G.; Hirano, T.; Kawai, Y.; Koseki, Y.; Schuldt, J.C. Multi-Input Functional Encryption with Controlled Decryption, IEICE Transactions on Fundamentals of Electronics. Commun. Comput. Sci. 2021, 104, 968–978. [Google Scholar]
  87. Alexandros, B.; Antonis, M.; Amjad, U. A Privacy-Preserving Reputation System Through Multi-Input Functional Encryption. In Proceedings of the Secure IT Systems: 25th Nordic Conference, NordSec 2020, Virtual Event, 23–24 November 2020; Springer: Berlin/Heidelberg, Germany, 2021; pp. 111–126. [Google Scholar]
  88. Zhu, H.; Wang, Y.; Wang, C. An efficient identity-based proxy signcryption using lattice. Future Gener. Comput. Syst. 2021, 117, 321–327. [Google Scholar] [CrossRef]
  89. Abdullah, L.; Dootio, M.A. Multi-Layer Latency Aware Workload Assignment of E-Transport IoT Applications in Mobile Sensors Cloudlet Cloud Networks. Electronics 2021, 10, 1719. [Google Scholar] [CrossRef]
  90. Yang, L.; Li, J. Improved certificate-based signature scheme without random oracles. IET Inf. Secur. 2016, 10, 80–86. [Google Scholar]
  91. Nie, H.; Li, Y. NCLAS: A novel and efficient certificateless aggregate signature scheme, Secure Communication. Networks 2016, 9, 3141–3151. [Google Scholar]
  92. Lakhan, A.; Jin, L. Dynamic Application Partitioning and Task Scheduling Secure Schemes for Bio-Sensors Healthcare Workload in Mobile Edge Cloud. Electronics 2021, 10, 2797. [Google Scholar] [CrossRef]
  93. Pakniat, N.; Noroozi, M.M. Cryptanalysis of a certificateless aggregate signature scheme. In Proceedings of the 9th Conference of Command, Control, Communications and Computer Intelligence, Tehran, Iran, 14 December 2016. [Google Scholar]
  94. Moraes, J.L.; Rocha, M.X.; Vasconcelos, G.G.; Filho, J.E.V.; de Albuquerque, V.H.C. Advances in Photopletysmography Signal Analysis for Biomedical Applications. Sensors 2018, 18, 1894. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  95. Sandeep, P.; Pombo, N.; Felizardo, V.; Garcia, N.; Sodhro, A.H.; Mukhopadhyay, S.C. Towards Machine Learning Enabled Security Framework for IoT-based Healthcare. In Proceedings of the 13th IEEE International Conference on Sensing Technology (ICST), Sydney, Australia, 2–4 December 2019; pp. 1–6. [Google Scholar]
  96. Magsi, H.; Sodhro, A.H.; Chachar, F.A.; Abro SA, K.; Sodhro, G.H.; Pirbhulal, S. Evolution of 5G in Internet of medical things. In Proceedings of the 2018 international conference on Computing, Mathematics and Engineering Technologies (iCoMET), Sukkur, Pakistan, 3–4 March 2018; pp. 1–8. [Google Scholar]
  97. Hameed, S.S.; Hassan, W.H.; Latiff, L.A.; Ghabban, F. A Systematic Review of Security and Privacy Issues in the Internet of Medical Things; the Role of Machine Learning Approaches. PeerJ Comput. Sci. 2021, 7, e414. [Google Scholar] [CrossRef] [PubMed]
  98. Talat, R.; Obaidat, M.S.; Muzammal, M. A decentralised approach to privacy preserving trajectory mining. Future Gener. Comput. Appl. 2020, 102, 382–392. [Google Scholar] [CrossRef]
  99. Zahid, N.; Sodhro, A.H.; Zafar, R.F.; Zahid, B.; Khan, S.A.; Akhter, F. Regression-based Transmission Power Control for Green Healthcare. In Proceedings of the 2nd IEEE International Conference on Computing, Mathematics and Engineering Technologies (iCoMET), Sukkur, Pakistan, 30–31 January 2019; pp. 1–9. [Google Scholar]
  100. Zhang, T.; Sodhro, A.H.; Luo, Z.; Zahid, N.; Nawaz, M.W.; Pirbhulal, S.; Muzammal, M. A Joint Deep Learning and Internet of Medical Things Driven Framework for Elderly Patients. IEEE Access 2020, 8, 75822–75832. [Google Scholar] [CrossRef]
  101. Ahmad, I.; Shahabuddin, S.; Malik, H.; Harjula, E.; Leppänen, T.; Loven, L.; Riekki, J. Machine Learning Meets Communication Networks: Current Trends and Future Challenges. IEEE Access 2020, 8, 223418–223460. [Google Scholar] [CrossRef]
  102. Memon, S.K.; Nisar, K.; Hijazi, M.H.A. A review on 802.11 MAC protocols industrial standards, architecture elements for providing QoS guarantee, supporting emergency traffic, and security: Future directions. J. Ind. Inf. Integr. 2021, 24, 100225. [Google Scholar]
  103. Lin, Y.; Jin, X.; Chen, J. An analytic computation-driven algorithm for Decentralized Multicore Systems. Future Gener. Comput. Syst. 2019, 96, 101–110. [Google Scholar] [CrossRef]
  104. Sodhro, A.H.; Wang, L. Decentralized Energy Efficient Model for Data Transmission in IoT-based Healthcare System. In Proceedings of the 93rd IEEE Vehicular Technology Conference (VTC) 2021-Spring, Helsinki, Finland, 25–28 April 2021. [Google Scholar]
  105. Zahid, N.; Sodhro, A.H.; Al-Rakhami, M.S.; Wang, L.; Gumaei, A.; Pirbhulal, S. An Adaptive Energy Optimization Mechanism for Decentralized Smart Healthcare Applications. In Proceedings of the 93rd IEEE Vehicular Technology Conference (VTC) 2021-Spring, Helsinki, Finland, 25–28 April 2021. [Google Scholar]
  106. Lakhan, A.; Dootio, M.A.; Sodhro, A.H.; Sandeep, S.; Groenli, T.M.; Khokhar, M.S.; Wang, L. Cost-Efficient Service Selection and Execution and Blockchain-Enabled Serverless Network for Internet of Medical Things. Math. Biosci. Eng. 2021, 18, 7344–7362. [Google Scholar] [CrossRef] [PubMed]
  107. Nykvist, C.; Larsson, M.; Sodhro, A.H.; Gurtov, A. A Lightweight Portable Intrusion Detection Communication System for Auditing Applications. Int. J. Commun. Syst. 2020, 33, e4327. [Google Scholar] [CrossRef]
  108. Magsi, H.; Sodhro, A.H.; Al-Rakhami, M.S.; Zahid, N.; Pirbhulal, S.; Wang, L. A Novel Adaptive Battery-Aware Algorithm for Data Transmission in IoT-Based Healthcare Applications. Electronics 2021, 10, 367. [Google Scholar] [CrossRef]
  109. Bolton, T.; Dargahi, T. On the Security and Privacy Challenges of Virtual Assistants. Sensors 2021, 21, 2312. [Google Scholar] [CrossRef] [PubMed]
  110. Borhani, M.; Liyanage, M. Chapter 09: Secure and Resilient Communications in the Industrial Internet (Ch: 1.9). In Guide to Disaster-Resilient Communication Networks; Springer: Berlin/Heidelberg, Germany, 2020. [Google Scholar]
  111. Dootio, M.A.; Lakhan, A. Secure and failure hybrid delay enabled a lightweight RPC and SHDS schemes in Industry 4.0 aware IIoHT enabled fog computing. Math. Biosci. Eng. 2022, 19, 513–536. [Google Scholar] [CrossRef]
  112. Goldberger, A.I.; Amaral, L.A.N.; Glass, I.; Hausdorff, J.M. PhysioBank, PhysioToolkit, and PhysioNet: Components of a New Research Resource for Complex Physiologic Signals. Circulation 2000, 101, e215–e220. [Google Scholar] [CrossRef] [Green Version]
  113. Schalk, G.; McFarland, D.J.; Hinterberger, T.; Birbaumer, N.; Wolpaw, J.R. BCI2000: A General-Purpose Brain-Computer Interface (BCI) System. IEEE Trans. Biomed. Eng. 2004, 51, 1034–1043. [Google Scholar] [CrossRef] [PubMed]
  114. Brieman, L. Random Forests. Mach. Learn. 2001, 45, 5–32. [Google Scholar] [CrossRef] [Green Version]
Figure 1. Proposed Cognitive Authentication Framework for smart Healthcare Applications.
Figure 1. Proposed Cognitive Authentication Framework for smart Healthcare Applications.
Sensors 22 02101 g001
Figure 2. Energy Efficiency during compressive sensing in IoT devices.
Figure 2. Energy Efficiency during compressive sensing in IoT devices.
Sensors 22 02101 g002
Figure 3. Battery Lifetime and Authentication level of IoT devices.
Figure 3. Battery Lifetime and Authentication level of IoT devices.
Sensors 22 02101 g003
Figure 4. Reliability of IoT devices in terms of RSSI.
Figure 4. Reliability of IoT devices in terms of RSSI.
Sensors 22 02101 g004
Table 1. Related Works.
Table 1. Related Works.
Ref. No.ApplicationsProposed SolutionMeritsDemerits
[1,2,3,4,5,6,7,8,9,10]EEG, ECG, Secure BSN for medical careSecurity and privacyEnergy efficientComplex and inefficient
[10,11,12,13,14,15]Smart, secure, and private media and bio-signal based Healthcare, IoT, physiological signalsSecure power controlDuty-cycle, data rateHigh energy and battery drain during media transmission
[16,17,18,19,20]Vital sign signals, security in cloud healthcare, EEG, ECG, medical IoTCloud and battery enabledFairy and battery efficientLess power-aware and secure
[21,22,23,24,25]WSNs, Secure and energy-aware IoT and BSN, EEG, vital sign signalsFrameworks and protocolsExtensive survey for healthcare Not focused on mobile healthcare
[26,27,28,29,30]Medical IoT, EEG, Data integrity and security in healthcareEnergy-aware and routing protocols Energy optimization and efficient routingComplex and less battery-efficient
[31,32,33,34,35]EEG, Privacy in medical industrial applications, smart healthcareEnergy harvesting and duty-cycle enabled Battery and energy-awareInappropriate for medical healthcare
[36,37,38]EEG, medical IoT, Security and privacy in Telemedicine and BANQoS optimization based Efficient QoS managementLess Battery and energy -efficient for healthcare
[39,40,41]EEG, ECG, SpO2, smart and Secure healthcare, efficient Cellular networks TPC and relay selection based Novel Architecture and resource allocation methodHigh battery and energy drain in medical healthcare system
[42,43,44]Private and secure communication systemsTPC and resource allocationEnergy optimization in wireless and sensor networksComplex and less reliable for dynamic healthcare
[45,46,47,48]ECG based secure BSN, Telemedicine, remote healthcareEnergy and battery-based frameworks and method Efficient resource allocationComplex and less battery-aware for medical services
[49,50,51]Resource allocation in smart medical networks, EEGTPC and radio-awareIntelligent resource monitoring in radio networks Unsuitable for healthcare system
[52,53,54,55,56]Efficient and secure Future Networks, EEG, vital sign signalsQoS and Energy Scavenging Novel energy and QoS efficientComplex and less reliable for healthcare system
[57,58,59,60,61]ECG, EEG, physiological signals, smart healthcare, IoT, lifecycleTPC and QoS-aware framework Detailed surveyNot focus at joint duty-cycle and TPC
[62,63,64,65,66]Secure and cryptographic IoT for healthcare Energy and battery-oriented Novel Physical layer and framework for healthcareComplex, less reliable without duty cycle
[67,68,69,70]Green, battery-aware healthcare, BSN, medical IoT, ECG, EEGFuzzy based secure Secure home monitoringHigh energy drain
[71,72,73,74]EEG, ECG, secure and pervasive WSNTPC and battery-based Efficient media transmission More battery drain
[75,76,77]Smart healthcare, Biometric based IoT, vital sign signalsFramework and battery-awareEfficient lifecycle management Less energy saving
[78,79,80,81,82,83]EEG, medical IoT, Secure Telemedicine and CPSOptimal resource allocationQoS monitoring and managementMore energy and battery drain
[84,85,86,87,88,89,90]EEG, healthcare, Ubiquitous secure and digital basedTPC based and frameworkNovel ECG monitoring algorithm and frameworkMore battery drain
[91,92,93,94,95,96,97,98]Smart and Green systems, EEG, SecurityRouting protocols and frameworkRouting and battery-based More energy dissipation
[99,100,101,102,103,104,105,106,107,108,109,110]Smart healthcare, Cryptography and privacyTPC-awareNovel Framework and methodHigh battery drain
[111,112,113,114]BCI, EEG datasetsEDF tool for dataPerformance metricsRF classifier
Table 2. Experimental analysis of EEG data by using Random Forest classifier.
Table 2. Experimental analysis of EEG data by using Random Forest classifier.
SubjectAccuracyTP RatePrecisionAUC
S186.01%0.860.9020.956
S267.3%0.6700.6540.836
S390.01%0.900.9510.956
S496.11%0.9610.9610.987
S564.41%0.6440.650.713
S662.34%0.6230.6240.81
S760.12%0.6010.620.713
S889.37%0.8940.8920.951
S984.11%0.8410.800.930
S1099.43%0.9940.9651
S1195.73%0.960.9650.988
S1288.41%0.8840.8150.875
S1360.17%0.6020.6010.80
S1461.38%0.6140.6020.780
S1559.44%0.5940.6730.804
S1695.31%0.9530.9540.985
S1789.43%0.8940.9100.976
S1890.37%0.9040.9000.968
S1961.42%0.6140.6010.801
S2098.31%0.9830.9830.976
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Sodhro, A.H.; Sennersten, C.; Ahmad, A. Towards Cognitive Authentication for Smart Healthcare Applications. Sensors 2022, 22, 2101. https://doi.org/10.3390/s22062101

AMA Style

Sodhro AH, Sennersten C, Ahmad A. Towards Cognitive Authentication for Smart Healthcare Applications. Sensors. 2022; 22(6):2101. https://doi.org/10.3390/s22062101

Chicago/Turabian Style

Sodhro, Ali Hassan, Charlotte Sennersten, and Awais Ahmad. 2022. "Towards Cognitive Authentication for Smart Healthcare Applications" Sensors 22, no. 6: 2101. https://doi.org/10.3390/s22062101

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop