Next Article in Journal
Active Learning Methodology for Expert-Assisted Anomaly Detection in Mobile Communications
Next Article in Special Issue
Shedding Light on Gas-Dynamic Effects in Laser Beam Fusion Cutting: The Potential of Background-Oriented Schlieren Imaging (BOS)
Previous Article in Journal
Soil Deformation after Water Drop Impact—A Review of the Measurement Methods
Previous Article in Special Issue
In-Line Mach Zehnder Interferometer Based on Ytterbium Doped Fiber with Up-Taper Structure in Fiber Ring Laser and Its Application in Sensing
 
 
Article
Peer-Review Record

Comparison of Different Linewidth Measuring Methods for Narrow Linewidth Laser

Sensors 2023, 23(1), 122; https://doi.org/10.3390/s23010122
by Ziqi Zheng, Qiaoxia Luo, Xian Wang, Xiaohui Ma, Wei Zhang, Wentan Fang, Xiaolin Chen, Song Huang, Yong Zhou * and Weiqing Gao *
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Reviewer 3:
Sensors 2023, 23(1), 122; https://doi.org/10.3390/s23010122
Submission received: 19 October 2022 / Revised: 29 November 2022 / Accepted: 20 December 2022 / Published: 23 December 2022
(This article belongs to the Special Issue Advances in Fiber Laser Sensors)

Round 1

Reviewer 1 Report

Very nice paper, it is well written. I've two minor comments,

1. No dots after Figure/Figures
2. Line 170: can't --> can not

Author Response

Please see the attachment

Author Response File: Author Response.docx

Reviewer 2 Report

The article is about Research on the Different Linewidth Measuring Methods for Narrow Linewidth Laser. 

There are only a few remarks/questions to be clarified by the authors, namely:

1.     There exist some undefined acronyms in the text, which need to be properly declared.

2.     This paper's abstract needs to be revised in light of current difficulties and the new methodology's solution.

3.     Please explain the simulation and experimental platforms in more detail so the reader can easily understand them. Please replace Figure 1 with a photograph of the experiment. it would add more value to this article.

4.     Line 95-96: Please explain why these limitations are at 310 mW and 1.4 µW?

 

5.     What are the directions for further research (e.g. measurements on real objects under normal environmental conditions).?

Author Response

Please see the attachment

Author Response File: Author Response.docx

Reviewer 3 Report

In this work, authors demonstrated a SIL to induce SBS effect. Successively, 3 linewidth measurement methods are used for further analysis. Scientifically, I don't find any significant mistakes. Some comments to improve the manuscript as below:

1. The title is too general! "Research on...." not really appropriate for this manuscript. An example, "Comparison of linewidth measurement method...." may be more appropriate.

2. Figure 1 is too small to read, please improve the figure presentation.

3. More in-depth discussion is needed to elaborate pros & cons of DSHI, SCELD and Voigt fitting.

4. There is a room for authors to improve the English presentation.

Author Response

Please see the attachment

Author Response File: Author Response.docx

Round 2

Reviewer 1 Report

I am happy to approve this submission.

Reviewer 2 Report

The corrections were satisfactory. I agree to the publication of this paper.

Reviewer 3 Report

In the revised manuscript, I humbly believe that the authors have improved the manuscript to meet the minimum requirement to publish in Sensors

Back to TopTop