Next Article in Journal
MoReLab: A Software for User-Assisted 3D Reconstruction
Next Article in Special Issue
Data, Signal and Image Processing and Applications in Sensors II
Previous Article in Journal
A 3D Anisotropic Thermomechanical Model for Thermally Induced Woven-Fabric-Reinforced Shape Memory Polymer Composites
Previous Article in Special Issue
Multi-Task Learning Radar Transformer (MLRT): A Personal Identification and Fall Detection Network Based on IR-UWB Radar
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Near-Space Wide-Area and High-Resolution Imaging System Design and Implementation

1
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
2
Key Laboratory of Computational Optical Imaging Technology, Chinese Academy of Sciences, Beijing 100094, China
3
School of Optoelectronics, University of Chinese Academy of Sciences, Beijing 100094, China
*
Author to whom correspondence should be addressed.
Sensors 2023, 23(14), 6454; https://doi.org/10.3390/s23146454
Submission received: 15 May 2023 / Revised: 4 July 2023 / Accepted: 5 July 2023 / Published: 17 July 2023
(This article belongs to the Special Issue Data, Signal and Image Processing and Applications in Sensors III)

Abstract

:
The near-space atmosphere is thin, and the atmospheric refraction and scattering on optical observation is very small, making it very suitable for wide-area and high-resolution surveillance using high-altitude balloon platforms. This paper adopts a 9344 × 7000 CMOS sensor to obtain high-resolution images, generating large-field-of-view imaging through the swing scanning of the photoelectric sphere and image stitching. In addition, a zoom lens is designed to achieve flexible applications for different scenarios, such as large-field-of-view and high-resolution imaging. The optical design results show that the camera system has good imaging quality within the focal length range of 320 mm–106.7 mm, and the relative distortion values at different focal lengths are less than 2%. The flight results indicate that the system can achieve seamless image stitching at a resolution of 0.2 m@20 km and the imaging field of view angle exceeds 33°. This system will perform other near-space flight experiments to verify its ultra-wide (field of view exceeding 100°) high-resolution imaging application.

1. Introduction

Aerial remote sensing is a comprehensive detection technology that uses optical, radar, and other technologies to obtain ground information through carrier platforms, such as manned aircraft, unmanned aerial vehicles, balloons, etc. It is flexible, low-cost, has a better vibration environment compared to airborne platforms, and is widely used in disaster monitoring, topographic mapping, military reconnaissance, and other fields [1,2,3].
Wide-area and high-resolution imaging technology is an important means of obtaining large, wide, and high-resolution ground information, and is also a key development direction in the field of remote sensing imaging in various countries around the world [4,5,6]. Near space generally refers to the space between 20 km and 100 km above the ground. The atmosphere in the adjacent space is thin, and the influence of water vapor, atmospheric refraction, and scattering on optical observation is very small, and it is very suitable for wide area surveillance [7].
As the most important indicators to measure the performance of imaging systems, width and resolution are two mutually constraining aspects of the technology. Wide-area and high-resolution imaging systems have broad application requirements, and researchers all over the world have proposed various new imaging structures and special methods to achieve wide-field-of-view and high-resolution imaging, including high-resolution camera scanning, multi-camera imaging, biomimetic optical imaging, and sensor array splicing imaging. High-resolution camera scanning imaging utilizes a high-resolution camera to scan and capture a large number of images, which can then be concatenated to obtain high-resolution images with a wide field of view. This method is a mature technology with high engineering reliability and the ability to freely adjust the imaging field of view and resolution, and it has other advantages due to its lightweight structure and simple operation control [8,9,10]. Multi-camera combined imaging indicates that the imager uses multiple imaging devices to capture spatial scenes at the same time, and each adjacent imaging device has a certain field of view overlap, a wide-field-of-view high-resolution image is obtained through the stitching of captured images; this method eliminates the rotating scanning mechanical structures and solves the time delay problem of the single camera scanning and shooting method [11,12]. The biomimetic optical imaging system is similar to multi-camera combination imaging, with the main difference being the design of the optical lens. It consists of dozens or even thousands of stacked or juxtaposed small imaging components with its wide-field-of-view decomposition, compact structure, and good multi-target fast parallel detection and tracking functions [13,14]; however, the pixel number of a single sensor still cannot meet practical application requirements. Therefore, it is necessary to integrate and splice multiple sensors to obtain larger pixel scale detectors. This solution has a high implementation cost and requires high splicing accuracy, and it is mainly used in large astronomical telescopes [15,16,17].
The aerial high-resolution camera is based on an optical system with a large aperture and long focal length. Under the condition of maintaining the spatial resolution, an increase in the imaging width will result in a rapid increase in the complexity, volume, and weight of the system, which are limited by the loading capacity of the platform and the attitude control capability. High-precision pose control and motion compensation technology have become key technologies that need to be addressed in the development process of large, wide, and high-resolution aerial camera systems.
In this paper, a high-resolution camera is designed and used for fine imaging of ground objects, and wide coverage is achieved through swing scanning by a photoelectric sphere. Due to the significant reduction in the field of view required for single imaging, it is easier to meet the constraints of camera volume and weight. The swing scanning achieves large area coverage by swinging the optical axis of the high-resolution camera along the wingspan direction. During the scanning process, the camera performs multiple exposure actions to obtain high-resolution images of different orientations in the wingspan direction. At the same time, the camera system follows the platform forward to achieve coverage in the flight direction, and then forms a large range of high-resolution images through stitching methods.
According to different image registration methods, image stitching is generally divided into three types: grayscale-based stitching methods, transform domain-based stitching methods, and feature-based stitching methods. The grayscale-based registration method is used to select a template in a fixed window from the reference image, search from the image to be registered, and use some evaluation method as the registration measurement to find the optimal registration position. The main stitching algorithms include the cross-correlation method, mutual information method, block matching method, ratio matching method, and grid matching method [18,19,20,21]. The mosaic method based on the transform domain is used to carry out some transformation on the image. The parameters of this mathematical transformation are separated by the method of parameter separation, and then the invariant is constructed. After matching the transformation model, the subsequent mosaic process is carried out. The main algorithms include wavelet transform, phase correlation, trace transform, and polar coordinate transform [22,23,24,25]. The feature-based stitching method is used to extract certain invariant features, such as interest points, lines, textures, etc., then match and calculate the transformation parameters between images, and finally complete the stitching. Feature-based stitching is currently the most widely used method, including Moravec, Harris, SIFT, SURF, ASIFT, GLOH, PCASIFT, and other algorithms [26,27,28,29,30].
The second part of this article mainly introduces the design of the wide-area and high-resolution imaging system. Firstly, the optical design of a high-resolution camera is introduced, mainly including the optical design, imaging quality analysis, thermal analysis, and tolerance analysis—the mechanical and electronic design of the camera are also introduced. Secondly, this paper introduces the design of the stable platform and the design of the swing scanning method. The third part of this article mainly introduces the flight verification results, including the image stitching results and high-resolution results.

2. Wide-Area and High-Resolution System Design

The near-space ball-borne wide-area and high-resolution imaging system mainly consists of a photoelectric sphere, a high-resolution camera, and a control system. The high-resolution camera is installed inside the photoelectric sphere and achieves high-resolution imaging with a large field of view through the rotation of the photoelectric sphere. The control system mainly generates the image collection and maintains control of the high-resolution camera, as well as the motion control of the photoelectric sphere. The composition diagram of the system is shown in Figure 1.
When the system is powered on, the high-resolution camera and the micro-industrial computer start working. The camera image data is sent to the micro-industrial computer automatically, and the micro-industrial computer stores the image data at the specified address. This address is set as a shared address, and the image data can be captured through the Internet. The main control module can set the parameters of the camera, such as the camera focal length, exposure time, and the pitch and azimuth angles of the photoelectric sphere. It is also possible to control the power up/down of the photoelectric sphere and the camera.
The ground console sends commands through the RS422 serial port, and the command data is transmitted to the public IP through the serial server. The ball-mounted serial port server obtains data from the public IP through satellite–Internet communication and sends commands to the main control module through the RS422 serial port. The main control module collects information, such as the angle and attitude of the photoelectric sphere, transmits it to the onboard serial port server through the RS422 serial port, and then transmits it to the public IP through satellite communication.
The main indicators of the system are shown in Table 1.
Section 2.1 mainly introduces the design and analysis of high-resolution cameras, including their optical design and analysis, thermal analysis, tolerance analysis, and structural and electronic design. Section 2.2 introduces the design of the photoelectric sphere and swing imaging schemes.

2.1. High-Resolution Camera Design

2.1.1. Optical Analysis

This paper uses the GMAX3265 CMOS image sensor developed by Gpixel. The sensor has 65 million pixels, and the size of each pixel size is 3.2 μm. Its characteristics consist of a large pixel array, low readout noise, and a global shutter function. The main technical indicators are shown in Table 2 and the quantum efficiency curve is shown in Figure 2.
In order to improve the adaptability and performance of the high-resolution camera, the optical part is designed as a zoom lens. The optical system needs to design a set of high-resolution imaging lenses, and the primary optical parameters are calculated according to the requirements, as shown in Table 3.

2.1.2. Optic System Design

For the purpose of high-resolution imaging, the long focal length of the optical system is relatively large. Considering the limitations of the photoelectric sphere platform on load size in this project, the design process needs to compress the lens structure size as much as possible. Through the complex design of the initial structure, a three-fold zoom optical system with a long focal length of 320 mm, a short focal length of 106.7 mm, and F/# 4.3 was ultimately obtained. The optical path structure is shown in Figure 3, including two moving components. The movement of the zoom moving component from the short to long focal length is 33.1 mm, and the compensation moving component from the short to long focal length is 27.5 mm. The total length of the optical path is 310 mm, with a maximum aperture of 90 mm. There are 20 optical lenses, with a total weight of less than 1.8 kg.
The evaluation of the imaging quality of an optical system mainly considers the modulation transfer function (MTF), point plot, and distortion curve. According to the task requirements, the imaging quality of the optical system on the five preset focal segments are examined separately.
  • f = 320 mm
From the data of the telephoto endpoint of the optical system, the maximum RMS radius of the diffuse spot within the field of view is about 1.8 μm, as shown in Figure 4, which is less than a pixel size. From the MTF curve, the system has ideal image quality. At a Nessler frequency of 156 lp/mm, the full field MTF is close to 0.4, corresponding to an optical angular resolution of:
σ = 1 N q f = 20   μ rad
When the resolution requirement of 20 μrad is met, the relative distortion curve of the system is as follows—with a maximum relative distortion of less than 0.4% in the full field of view.
2.
f = 260 mm
From the data of the telephoto endpoint of the optical system, the maximum RMS radius of the diffuse spot within the field of view is about 2 μm, as shown in Figure 5, which is less than a pixel size. From the MTF curve, the system has ideal image quality. At a Nessler frequency of 137 lp/mm, the full field MTF is close to 0.4, corresponding to an optical angular resolution of:
σ = 1 N q f = 28   μ rad
When the resolution requirement of 28 μrad is met, the relative distortion curve of the system is as follows—with a maximum relative distortion of less than 0.3% in the full field of view.
3.
f = 213 mm
From the data of the telephoto endpoint of the optical system, the maximum RMS radius of the diffuse spot within the field of view is about 2.3 μm, as shown in Figure 6, which is less than a pixel size. From the MTF curve, the system has ideal image quality. At a Nessler frequency of 137 lp/mm, the full field MTF is close to 0.4, corresponding to an optical angular resolution of:
σ = 1 N q f = 34   μ rad
When the resolution requirement of 35 μrad is met, the relative distortion curve of the system is as follows—with a maximum relative distortion of less than 0.5% in the full field of view.
4.
f = 160 mm
From the data of the telephoto endpoint of the optical system, the maximum RMS radius of the diffuse spot within the field of view is about 2.6 μm, as shown in Figure 7, which is less than a pixel size. From the MTF curve, the system has ideal image quality. At a Nessler frequency of 130 lp/mm, the full field MTF is close to 0.4, corresponding to an optical angular resolution of:
σ = 1 N q f = 48   μ rad
When the resolution requirement of 50 μrad is met, the relative distortion curve of the system is as follows—with a maximum relative distortion of less than 1.0%.
5.
f = 106.7 mm
From the data of the telephoto endpoint of the optical system, the maximum RMS radius of the diffuse spot within the field of view is about 3.0 μm, as shown in Figure 8, which is less than a pixel size. From the MTF curve, the system has ideal image quality. At a Nessler frequency of 104 lp/mm, the full field MTF is close to 0.4, corresponding to an optical angular resolution of:
σ = 1 N q f = 90   μ rad
When the resolution requirement of 90 μrad is met, the relative distortion curve of the system is as follows—with a maximum relative distortion of less than 2.0% in the full field of view.

2.1.3. Thermal Analysis

When the temperature environment changes, the image quality of the optical system will change due to the influence of temperature defocusing. The reason for this result is that the temperature effect of ultra-low chromatic aberration glass is obvious, making the focal plane position of the system more sensitive to temperature. The continuous zoom lens uses a front motion group for temperature compensation to eliminate the influence of temperature effects. Within the temperature range of +60 °C to −45 °C, the transfer function curve remains basically constant, as shown in Figure 9.

2.1.4. Tolerance Analysis

For the optical system that has been designed, a tolerance analysis is conducted to fully consider the impact of processing and assembly on the imaging quality of the system. The optical lens group adopts the centering machining process, and the tolerances are selected based on the experience values of medium- and high-precision objective lenses.
In order to predict the comprehensive effect of all tolerances during the overall assembly process of the system, a Monte Carlo method was used to analyze the influence of tolerances based on the design software. The MTF value of the optical system was used as the image quality evaluation index, and the spatial frequency was selected based on the optical angular resolution of the short and long focal ends.
As is shown in the tolerance analysis result in Figure 10, according to the selected component processing and assembly tolerances, the lens can be processed and adjusted, with a 60% probability of achieving a full field of view range with a selected spatial frequency MTF greater than 0.15, and a high one-time pass rate, which can meet production requirements.

2.1.5. Electrical and Mechanical Design

The electronic system of a high-resolution camera consists of CMOS sensors, an image data processing interface, signal processor, power converters, control input, and image output interfaces. The composition of the camera system is shown in Figure 11.
The development of the detector has gone through multiple stages, including scheme design, structural design, PCB design, prototype debugging, and overall testing. The PCB circuit stack installation structure of the detector is shown in Figure 12.
To ensure the implementation of optical design, the mechanical structure of the camera mainly includes three parts: a front mirror component, a focusing mirror component, and a detector component, as shown in Figure 13.
The front mirror component contains the five optical lenses of the camera. In order to meet the requirements for the co-axiality of the optical path, structural stability, and ease of assembly and adjustment, the assembly adopts an integral cylindrical structure. The front mirror component mainly includes the mirror tube, protective cover, pins, compression rings and washer fixing parts, spacers, mirror boxes, trimming pads, etc. The lens barrel mainly provides support and positioning for various optical lenses and is fixedly connected to the focusing lens component.
The focusing mirror component includes the four optical lenses of this camera. Considering the optical design requirements and structural simplification, the component is designed as an I-type straight-through lens tube structure; this component is in the middle of the entire camera, and square flange plates are placed at both ends to connect the front mirror component and detector component. Since there is a lens in the optical system that is sensitive to changes in ambient temperature, a focusing module is placed in the focusing mirror assembly. The focusing module consists of a stepping motor, big and small gears, and photoelectric travel switches—and its corresponding structural parts. Through the design of the number of teeth, modulus, and pressure angle of the big and small gears, a reasonable reduction ratio is optimized. With the help of the electronic control system, the optical focusing requirements are met.
The temperature environment during camera operation fluctuates greatly, and a higher temperature will affect the imaging quality of the CMOS sensor. To ensure that the CMOS sensor operates in an ideal temperature environment, thermal conductivity cooling is used to timely dissipate the heat generated by the CMOS sensor during operation. There is a thermal conductivity plate on its back, with one end fixed to the back of the CMOS chip and an insulation pad added at the fixed position. The other end is led out, and then heat is transmitted to the thermal control component to achieve conducting cooling. The thermal conductivity plate is made of red copper (T3) with high thermal conductivity. To improve the thermal conductivity efficiency and increase the contact area, a combination of mechanical pressing and thermal adhesive bonding is used to fix it. The CMOS base is made of titanium alloy material, which has a certain strength and low thermal conductivity, which is conducive to the thermal control of CMOS chips.

2.2. Photoelectric Sphere and Swing Imaging Design

The design of the photoelectric sphere adopts a two axis and two frame stable system structure, and the high-resolution camera is loaded into the pitch frame. The design of the photoelectric platform adopts a spherical structure. On the one hand, the aerodynamic resistance of the spherical structure is smaller than that of other structures (plate, square, diamond, etc.) under the same conditions (same speed, same windward area); on the other hand, the product has good symmetry. During flight, when the azimuth and pitch frames move, the changes in their angular positions cause small changes in the driving torque, making system control easy to implement; thirdly, under certain conditions of stable platform rotation space, the internal space contained by the sphere is larger than that of other structures, and its load-bearing capacity is strong. The installation of the high-resolution camera in the photoelectric sphere is shown in Figure 14.
In the process of wide-area high-resolution imaging, the high-resolution camera operates in telephoto mode, with a photoelectric sphere azimuth angle of 90°—perpendicular to the flight direction—and an initial pitch angle of −90°, indicating ground imaging. The pitch direction of the photoelectric sphere provides different imaging fields of view for high-resolution cameras to take photos through steeper motions, as shown in Figure 15. Due to the very slow flight speed of high-altitude balloons, which is about 10 m/s, there is no need to consider the image shift in the direction of flight when performing swing imaging.
Due to the significant distortion caused by large angle squint, in order to reduce the level of image distortion, the sweep width coverage is 33.3°, the step angle is 3.5°, and the overlap rate in the span direction is 35%. The optical axis roll angle of each image frame in a single scanning cycle is uniformly distributed within the width range, and the values are shown in Table 4.
The SIFT algorithm is very robust in complex geometric images and radiative conditions and is currently the most commonly used registration algorithm. The process of SIFT is mainly divided into four stages: feature point detection, key point localization, direction allocation, and feature point description. Firstly, the scale space of the image is constructed by establishing a Difference of Gaussians (DOG) pyramid to extract feature points and obtain the first layer image through Gaussian blur.
L x , y , σ = G x , y , σ × I x , y
I x , y is the original image, and G x , y , σ is the Gaussian kernel, while x , y are the pixel coordinates, and σ is the scale factor, wherein the larger the σ , the clearer the image contour, and the smaller the σ , the more obvious the image details. The Gaussian kernel function is:
G x , y , σ = 1 2 π σ e x 2 + y 2 2 σ 2
The difference of Gaussians pyramid performs the DOG operation between two adjacent layers of images, which is shown as:
D x , y , σ = G x , y , k σ G x , y , σ × I x , y = L x , y , k σ L x , y , σ
When locating key points, it is necessary to filter out low-contrast extreme points and edge responses. It is necessary to obtain a 2 × 2 Hessian matrix by taking the derivative of the Gaussian convolution formula.
H = D x x D x y D y x D y y
The direction matching of feature points mainly estimates the direction of neighboring pixels of key points through the grayscale histogram of the image.
m x , y = L x + 1 , y L x 1 , y 2 + L x , y + 1 L x , y 1 2
θ x , y = t a n 1 L x , y + 1 L x , y 1 / L x + 1 , y L x 1 , y
m x , y   where represents the gradient value and θ x , y represents the gradient direction.

3. Results

In May 2022, a flight experiment was conducted to verify the functionality of the wide-area high-resolution imaging system. The focal length of the camera is set to 320 mm to achieve a resolution of 0.2 m@20 km, as shown in Figure 16. The car in Figure 16 occupies approximately 9 × 22 pixels, based on the resolution, and the actual size is approximately 1.8 m × 4.4 m, which is consistent with the actual situation.
We adopted the SIFT method to achieve the image stitching, where the coverage is 33.3° and the image stitching result is shown in Figure 17, indicating that the wide-area and high-resolution imaging system has a good image stitching effect, and the overlap rate meets the seamless stitching requirements.

4. Conclusions

This paper adopts a 64 M pixels CMOS sensor to obtain high-resolution images and generates a large-field-of-view image through the swing scanning of the photoelectric sphere. The flight results indicate that the system can achieve seamless image stitching at a resolution of 0.2 m@20 km and coverage of 33.3°.
In addition, the high-resolution camera adopts zoom lenses (focal length range of 320 mm–106.7 mm) to achieve flexible applications. For application scenarios with ultra-wide (field of view exceeding 100°) high-resolution imaging, ground resolution sharply decreases with an increase in the scanning angle, and the resolution of the edge area is about half of the center area, seriously affecting the image stitching effect. The zoom swing scanning wide-area and high-resolution imaging system in this article can adjust the camera focal length in real-time during the swing scanning process, ensuring that the imaging resolution remains unchanged. It provides a new solution for ultra-wide and high-resolution imaging. This system will be used in other near-space flight experiments to verify its application.

Author Contributions

Software, W.Z.; Resources, Y.S.; Data curation, Y.Z.; Writing—original draft, Z.W.; Writing—review & editing, Z.Z. and G.W.; Visualization, X.L.; Supervision, M.H.; Project administration, L.Q.; Funding acquisition, L.Q. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the strategic priority research program of the Chinese Academy of Science (Grant NO: XDA17020600) and Youth Innovation Promotion Association CAS.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Ma, Y.; Chen, F.; Liu, J.; He, Y.; Duan, J.; Li, X. An automatic procedure for early disaster change mapping based on optical remote sensing. Remote Sens. 2016, 8, 272. [Google Scholar] [CrossRef] [Green Version]
  2. Balz, T.; Rocca, F. Reproducibility and replicability in sar remote sensing. IEEE J. Sel. Top. Appl. Earth Obs. Remote Sens. 2020, 13, 3834–3843. [Google Scholar] [CrossRef]
  3. Wang, G.; Murphy, D.; Oller, A.; Howard, H.R.; Anderson, A.B.; Rijal, S.; Myers, N.R.; Woodford, P. Spatial and temporal assessment of cumulative disturbance impacts due to military training, burning, haying, and their interactions on land condition of fort riley. Environ. Manag. 2014, 54, 51–66. [Google Scholar] [CrossRef]
  4. Iyengar, M.; Lange, D. The Goodrich 3rd generation DB-110 system: Operational on tac tical and unmanned aircraft. In Proceedings of the Airborne Intelligence, Surveillance, Reconnaissance (ISR) Systems and Applications III, Kissimmee, FL, USA, 19–20 April 2006; International Society for Optics and Photonics: Bellingham, WA, USA, 2006; Volume 6209, p. 620909. [Google Scholar]
  5. Greslou, D.; de Lussy, F.; Delvit, J.M.; Dechoz, C.; Amberg, V. Pleiades-Hr Innovative Techniques for Geometric Image Quality Commissioning. Int. Arch. Photogramm. Remote Sens. Spatial Inf. Sci. 2012, XXXIX-B1, 543–547. [Google Scholar] [CrossRef] [Green Version]
  6. Li, S.; Qiu, Y.; Hu, Y.; Gong, C.-L.; Qi, H.-X.; Wang, Y.-K. Research of wide swath image mosaic technology based on area-array detector adopting whiskbroom scanning mode. Proc. SPIE 2019, 220, 827–833. [Google Scholar]
  7. Wang, Z.; Huang, M.; Qian, L.; Zhao, B.; Wang, G. High-Altitude Balloon-Based Sensor System Design and Implementation. Sensors 2020, 20, 2080. [Google Scholar] [CrossRef] [Green Version]
  8. Nourbakhsh, I.; Acedo, C.; Sargent, R.; Strebel, C.; Tomokiyo, L.; Belalcazar, C. GigaPan conversations: Diversity and inclusion in the community. In Proceedings of the International Scientific Conference on Technology for Development, Lausanne, Switzerland, 8–10 February 2010. [Google Scholar]
  9. Ben-Ezra, M. A Digital Gigapixel Large-Format Tile-Scan Camera. Comput. Graph. Appl. IEEE 2011, 31, 49–61. [Google Scholar] [CrossRef] [PubMed]
  10. Zheng, G.; Ou, X.; Yang, C. 0.5 gigapixel microscopy using a flatbed scanner. Biomed. Opt. Express 2014, 5, 1–8. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  11. Taguchi, Y.; Koike, T.; Takahashi, K.; Naemura, T. TransCAIP: A live 3D TV system using a camera array and an integral photography display with interactive control of viewing parameters. IEEE Trans. Vis. Comput. Graph. 2009, 15, 841–852. [Google Scholar] [CrossRef]
  12. Xu, Y.; Zhou, Q.; Gong, L.; Zhu, M.; Ding, X.; Teng, R.K.F. High-speed simultaneous image distortion correction transformations for a multicamera cylindrical panorama real-time video system using FPGA. IEEE Trans. Circuits Syst. Video Technol. 2014, 24, 1061–1069. [Google Scholar] [CrossRef]
  13. Cogal, O.; Popovic, V.; Wellig, P. A new omni-directional multi-camera system for high resolution surveillance. In Proceedings of the Mobile Multimedia/Image Processing, Security, and Applications, Baltimore, MD, USA, 5–6 May 2014; p. 91200N. [Google Scholar]
  14. Song, Y.M.; Xie, Y.; Malyarchuk, V.; Xiao, J.; Jung, I.; Choi, K.-J.; Liu, Z.; Park, H.; Lu, C.; Kim, R.-H.; et al. Digital cameras with designs inspired by the arthropod eye. Nature 2013, 497, 95–99. [Google Scholar] [CrossRef] [PubMed]
  15. De Bruijne, J.; Kohley, R.; Prusti, T. Gaia: 1000 million stars with 100 CCD detectors. In Proceedings of the SPIE Astronomical Telescopes + Instrumentation, San Diego, CA, USA, 27 June–2 July 2010; International Society for Optics and Photonics: Bellingham, WA, USA, 2010; pp. 395–405. [Google Scholar]
  16. Kahn, S.M.; Kurita, N.; Gilmore, K.; Nordby, M.; O’Connor, P.; Schindler, R.; Oliver, J.; Van Berg, R.; Olivier, S.; Riot, V.; et al. Design and development of the 3.2 gigapixel camera for the Large Synoptic Survey Telescope. In Proceedings of the SPIE Astronomical Telescopes + Instrumentation, San Diego, CA, USA, 27 June–2 July 2010; SPIE: Bellingham, WA, USA, 2010; Volume 7735, p. 77350J. [Google Scholar]
  17. Neill, D.; Angeli, G.; Claver, C.; Hileman, E.; DeVries, J.; Sebag, J.; Xin, B. Overview of the LSST active optics system. In Proceedings of the Modeling, Systems Engineering, and Project Management for Astronomy VI, Montréal, QC, Canada, 22–24 June 2014; International Society for Optics and Photonics: Bellingham, WA, USA, 2014; Volume 9150, p. 91500G. [Google Scholar]
  18. Zhang, H.B.; Ling, J.; Lian, Y.Q. Fast mosaic detection for real-time video based on template matching strategy. In Proceedings of the 2012 International Conference on Image Analysis and Signal Processing, Huangzhou, China, 9–11 November 2012; IEEE: Piscataway, NJ, USA, 2012. [Google Scholar]
  19. Wang, W.; Lu, P.Z. An overview of digital image mosaic. Minimicro Syst.-Shenyang 2006, 27, 1347. [Google Scholar]
  20. Chailloux, C.; Le Caillec, J.-M.; Gueriot, D.; Zerr, B. Intensity-based block matching algorithm for mosaicing sonar images. IEEE J. Ocean. Eng. 2011, 36, 627–645. [Google Scholar] [CrossRef]
  21. Lee, H.-Y. Generation of photo-mosaic images through block matching and color adjustment. Int. J. Comput. Inf. Syst. Control. Eng. 2014, 8, 426–430. [Google Scholar]
  22. Ying, H.; Wang, L. Image stitching algorithm based on feature block and wavelet transform. Comput. Eng. Des. 2010, 31, 4. [Google Scholar]
  23. Sun, W.; Niessen, W.J.; Klein, S. Wavelet based free-form deformations for nonrigid registration. Medical Imaging 2014: Image Processing. In Proceedings of the International Society for Optics and Photonics, San Diego, CA, USA, 17–21 August 2014; Volume 9034. [Google Scholar]
  24. Zhang, J.; Ferdous, S.; Bian, H.; Bennamoun, M.; An, S. Forward-looking sonar image registration using polar transform. In Proceedings of the OCEANS 2016 MTS/IEEE Monterey, Monterey, CA, USA, 19–23 September 2016; IEEE: Piscataway, NJ, USA, 2016. [Google Scholar]
  25. Yang, F.; Wei, L.; Zhang, Z.; Tang, H. Image mosaic based on phase correlation and Harris operator. J. Comput. Inf. Syst. 2012, 8, 2647–2655. [Google Scholar]
  26. Li, C.K.; Yang, G.; Wu, J.; Wang, F. The UAV video image stitching based on improved moravec corner matching method. Int. J. Remote Sens. Appl. 2012, 2, 41–44. [Google Scholar]
  27. Zhang, Y.C. Improved Image Mosaic Measure Based on Harris Corner. Mech. Eng. 2017, 10, 20. [Google Scholar] [CrossRef]
  28. Huang, Z.Y.; Wang, H.H.; Li, Y. The Research of Image Mosaic Techniques Based on Optimized SIFT Algorithm. In Proceedings of the 2019 International Conference on Robotics Systems and Vehicle Technology, Wuhan, China, 18–20 October 2019. [Google Scholar]
  29. Liu, J.L.; Bu, F.L. Improved RANSAC features image-matching method based on SURF. J. Eng. 2019, 2019, 9118–9122. [Google Scholar] [CrossRef]
  30. Wang, X.; Li, Y.; Wei, H.; Liu, F. An ASIFT-based local registration method for satellite imagery. Remote Sens. 2015, 7, 7044–7061. [Google Scholar] [CrossRef] [Green Version]
Figure 1. Near-space-based wide-area and high-resolution imaging system.
Figure 1. Near-space-based wide-area and high-resolution imaging system.
Sensors 23 06454 g001
Figure 2. GMAX3265 Quantum Efficiency Curve.
Figure 2. GMAX3265 Quantum Efficiency Curve.
Sensors 23 06454 g002
Figure 3. Optical path structure of the lens.
Figure 3. Optical path structure of the lens.
Sensors 23 06454 g003
Figure 4. 320 mm analysis result: (a) Full color MTF curve; (b) Full color dot plot curve; (c) Focal length distortion curve.
Figure 4. 320 mm analysis result: (a) Full color MTF curve; (b) Full color dot plot curve; (c) Focal length distortion curve.
Sensors 23 06454 g004
Figure 5. 260 mm analysis result: (a) Full color MTF curve; (b) Full color dot plot curve; (c) Focal length distortion curve.
Figure 5. 260 mm analysis result: (a) Full color MTF curve; (b) Full color dot plot curve; (c) Focal length distortion curve.
Sensors 23 06454 g005
Figure 6. 213 mm analysis result: (a) Full color MTF curve; (b) Full color dot plot curve; (c) Focal length distortion curve.
Figure 6. 213 mm analysis result: (a) Full color MTF curve; (b) Full color dot plot curve; (c) Focal length distortion curve.
Sensors 23 06454 g006
Figure 7. 160 mm analysis result: (a) Full color MTF curve; (b) Full color dot plot curve; (c) Focal length distortion curve.
Figure 7. 160 mm analysis result: (a) Full color MTF curve; (b) Full color dot plot curve; (c) Focal length distortion curve.
Sensors 23 06454 g007
Figure 8. 106.7 mm analysis result: (a) Full color MTF curve; (b) Full color dot plot curve; (c) Focal length distortion curve.
Figure 8. 106.7 mm analysis result: (a) Full color MTF curve; (b) Full color dot plot curve; (c) Focal length distortion curve.
Sensors 23 06454 g008
Figure 9. Transfer function diagram of 320 mm telephoto after focusing compensation: (a) +60 °C; (b) −45 °C.
Figure 9. Transfer function diagram of 320 mm telephoto after focusing compensation: (a) +60 °C; (b) −45 °C.
Sensors 23 06454 g009
Figure 10. Tolerance analysis results: (a) 106.7 mm; (b) 320 mm.
Figure 10. Tolerance analysis results: (a) 106.7 mm; (b) 320 mm.
Sensors 23 06454 g010
Figure 11. Electrical composition of the camera.
Figure 11. Electrical composition of the camera.
Sensors 23 06454 g011
Figure 12. Electrical structure of the camera.
Figure 12. Electrical structure of the camera.
Sensors 23 06454 g012
Figure 13. Mechanical structure of the camera.
Figure 13. Mechanical structure of the camera.
Sensors 23 06454 g013
Figure 14. The installation of the high-resolution camera in the photoelectric sphere.
Figure 14. The installation of the high-resolution camera in the photoelectric sphere.
Sensors 23 06454 g014
Figure 15. Mode of photoelectric sphere and high-resolution camera.
Figure 15. Mode of photoelectric sphere and high-resolution camera.
Sensors 23 06454 g015
Figure 16. Result of the flight experiment image resolution.
Figure 16. Result of the flight experiment image resolution.
Sensors 23 06454 g016
Figure 17. Result of the flight experiment image stitching.
Figure 17. Result of the flight experiment image stitching.
Sensors 23 06454 g017
Table 1. Main performance indicators.
Table 1. Main performance indicators.
ItemData
Resolution0.2 m@20 km
Azimuth angle of photoelectric sphere−180° to 180°
Pitch angle of photoelectric sphere−140° to 140°
Table 2. GMAX3265 Image Sensor Index Parameter Table.
Table 2. GMAX3265 Image Sensor Index Parameter Table.
ItemData
effective number of pixels9344 × 7000
pixel size 3.2 μm × 3.2 μm
photosensitive area29.9 mm × 22.4 mm
image modemonochrome camera
image data bit 12 bit (max)
maximum of frame rate31 frame/s
dynamic range66 dB
peak quantum efficiency65.3%@500 nm
number of saturated electrons>9.0 ke−
read noise2.0 e−
dark current5.3 e−/p/s@40 °C
nyquist frequency156 lp/mm
consumption<2.1 W
Table 3. High-resolution camera optical parameters.
Table 3. High-resolution camera optical parameters.
ItemData
long focal length f L = 20000   m 3.2   μ m 0.2   m = 320   mm
short focal length f S = 320   mm 3 = 106.7   mm
horizontal field of long focal 2 ω = 2 × arctan 29.9   mm 2   ×   f L 5.3   °
vertical field of long focal 2 ω = 2 × arctan 22.4   mm 2   ×   f L 4 °
horizontal field of short focal 2 ω = 2 × arctan 29.9   mm 2   ×   f S 16.0 °
vertical field of short focal 2 ω = 2 × arctan 22.4   mm 2   ×   f S 12 °
Table 4. Photoelectric sphere rotation angle.
Table 4. Photoelectric sphere rotation angle.
Position NumberRotation Angle (°)Horizontal Angle Coverage (°)
1−14.0−16.65~−11.35
2−10.5−13.15~−7.85
3−7.0−9.65~−4.35
4−3.5−6.15~−0.85
50−2.65~2.65
63.50.85~6.15
77.04.35~9.65
810.57.85~13.15
914.011.35~16.65
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Wang, Z.; Huang, M.; Qian, L.; Sun, Y.; Lu, X.; Zhao, W.; Zhang, Z.; Wang, G.; Zhao, Y. Near-Space Wide-Area and High-Resolution Imaging System Design and Implementation. Sensors 2023, 23, 6454. https://doi.org/10.3390/s23146454

AMA Style

Wang Z, Huang M, Qian L, Sun Y, Lu X, Zhao W, Zhang Z, Wang G, Zhao Y. Near-Space Wide-Area and High-Resolution Imaging System Design and Implementation. Sensors. 2023; 23(14):6454. https://doi.org/10.3390/s23146454

Chicago/Turabian Style

Wang, Zhanchao, Min Huang, Lulu Qian, Yan Sun, Xiangning Lu, Wenhao Zhao, Zixuan Zhang, Guangming Wang, and Yixin Zhao. 2023. "Near-Space Wide-Area and High-Resolution Imaging System Design and Implementation" Sensors 23, no. 14: 6454. https://doi.org/10.3390/s23146454

APA Style

Wang, Z., Huang, M., Qian, L., Sun, Y., Lu, X., Zhao, W., Zhang, Z., Wang, G., & Zhao, Y. (2023). Near-Space Wide-Area and High-Resolution Imaging System Design and Implementation. Sensors, 23(14), 6454. https://doi.org/10.3390/s23146454

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop