Intelligent Wearable Wrist Pulse Detection System Based on Piezoelectric Sensor Array
Abstract
:1. Introduction
2. System Structure and Design
2.1. System Constitutes
2.2. New Piezoelectricity Sensor
2.3. System Acquisition Process
3. Experimental Results
3.1. Adaptive Pulse Finding
3.2. Denoise Processing
3.3. Feature Extraction and Classification
4. Discussion
5. Patents
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Charlton, P.H.; Mariscal Harana, J.; Vennin, S.; Li, Y.; Chowienczyk, P.; Alastruey, J. Modeling arterial pulse waves in healthy aging: A database for in silico evaluation of hemodynamics and pulse wave indexes. Am. J. Physiol.-Heart Circ. Physiol. 2019, 317, H1062–H1085. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Chu, Y.W.; Luo, C.H.; Chung, Y.F.; Hu, C.S.; Yeh, C.C. Using an array sensor to determine differences in pulse diagnosis—Three positions and nine indicators. Eur. J. Integr. Med. 2014, 6, 516–523. [Google Scholar] [CrossRef]
- Luo, C.-H.; Su, C.J.; Huang, T.Y.; Chung, C.Y. Non-invasive holistic health measurements using pulse diagnosis: I. Validation by three-dimensional pulse mapping. Eur. J. Integr. Med. 2016, 8, 921–925. [Google Scholar] [CrossRef]
- Wu, H.K.; Ko, Y.S.; Lin, Y.S.; Wu, H.T.; Tsai, T.H.; Chang, H.H. The correlation between pulse diagnosis and constitution identification in traditional Chinese medicine. Complement. Ther. Med. 2017, 30, 107–112. [Google Scholar] [CrossRef] [PubMed]
- Feng, X.; Feng, L.; Gao, H.; Wang, Q.S.; Xia, Y.M.; Xu, Z.X.; Wang, Y.Q. Characteristics of Pulse Parameters in Patients with Polycystic Ovary Syndrome Varied at Different Body Mass Index Levels. Evid.-Based Complement. Altern. Med. 2022, 2022, 7220011. [Google Scholar] [CrossRef] [PubMed]
- Gan, Z.; Zhang, D.; Huang, Z.; Chen, L. A preliminary study on discriminant analysis of syndrome types in the recovery period of stroke in traditional Chinese medicine. BioMed Res. Int. 2018, 2018, 6079595. [Google Scholar] [CrossRef] [PubMed]
- Lin, F.; Zhang, J.; Wang, Z.; Zhang, X.; Yao, R.; Li, Y. Research on feature mining algorithm and disease diagnosis of pulse signal based on piezoelectric sensor. Inform. Med. Unlocked 2021, 26, 100717. [Google Scholar] [CrossRef]
- Li, J.Q.; Li, R.; Chen, Z.Z.; Deng, G.Q.; Wang, H.; Mavromoustakis, C.X.; Song, H.; Ming, Z. Design of a continuous blood pressure measurement system based on pulse wave and ECG signals. IEEE J. Transl. Eng. Health Med. 2018, 6, 1900114. [Google Scholar] [CrossRef] [PubMed]
- Kabigting, J.E.; Chen, A.D.; Chang, E.J.H.; Lee, W.N.; Roberts, R.C. Mems pressure sensor array wearable for traditional Chinese medicine pulse-taking. In 2017 IEEE 14th International Conference on Wearable and Implantable Body Sensor Networks (BSN); IEEE: Piscatvie, NJ, USA, 2017. [Google Scholar]
- Murphy, J.C.; Morrison, K.; McLaughlin, J.; Manoharan, G.; Adgey, A.J. An Innovative Piezoelectric-Based Method for Measuring Pulse Wave Velocity in Patients with Hypertension. J. Clin. Hypertens. 2011, 13, 497–505. [Google Scholar] [CrossRef] [PubMed]
- Khan, M.U.; Aziz, S.; Akram, T.; Amjad, F.; Iqtidar, K.; Nam, Y.; Khan, M.A. Expert hypertension detection system featuring pulse plethysmograph signals and hybrid feature selection and reduction scheme. Sensors 2021, 21, 247. [Google Scholar] [CrossRef] [PubMed]
- Naqvi, S.Z.H.; Aziz, S.; Khan, M.U.; Asghar, N.; Rasool, G. Emotion Recognition System using Pulse Plethysmograph. In 2020 International Conference on Emerging Trends in Smart Technologies (ICETST); IEEE: Piscatvie, NJ, USA, 2020; pp. 1–6. [Google Scholar]
- Yang, P.; Stankevicius, D.; Marozas, V.; Deng, Z.; Liu, E.; Lukosevicius, A.; Dong, F.; Xu, L.; Min, G. Lifelogging data validation model for internet of things enabled personalized healthcare. IEEE Trans. Syst. Man Cybern. Syst. 2016, 48, 50–64. [Google Scholar] [CrossRef] [Green Version]
- Roguin, A. Scipione Riva-Rocci and the men behind the mercury sphygmomanometer. Int. J. Clin. Pract. 2006, 60, 73–79. [Google Scholar] [CrossRef] [PubMed]
- Chen, C.; Li, Z.; Zhang, Y.; Zhang, S.; Hou, J.; Zhang, H. A 3D Wrist Pulse Signal Acquisition System for Width Information of Pulse Wave. Sensors 2019, 20, 11. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Sun, Y.; Dong, Y.; Gao, R.; Chu, Y.; Zhang, M.; Qian, X.; Wang, X. Wearable pulse wave monitoring system based on MEMS sensors. Micromachines 2018, 9, 90. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Wang, P.; Zuo, W.; Zhang, H.; Zhang, D. Design and implementation of a multi-channel pulse signal acquisition system. In Proceedings of the 2012 5th International Conference on BioMedical Engineering and Informatics, Chongqing, China, 16–18 October 2012; IEEE: Piscatvie, NJ, USA, 2012; pp. 1063–1067. [Google Scholar]
- Chen, Y.Y.; Chang, R.S.; Jwo, K.W.; Hsu, C.C.; Tsao, C.P. A non-contact pulse automatic positioning measurement system for traditional Chinese medicine. Sensors 2015, 15, 9899–9914. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Liu, S.; Zhang, S.; Zhang, Y.; Geng, X.; Zhang, J.; Zhang, H. A novel flexible pressure sensor array for depth information of radial artery. Sens. Actuators A Phys. 2018, 272, 92–101. [Google Scholar] [CrossRef]
- Lee, Y.J.; Lee, J.; Lee, H.J.; Kim, J.Y. A study on correlation between BMI and oriental medical pulse diagnosis using ultrasonic wave. In 13th International Conference on Biomedical Engineering; Springer: Berlin/Heidelberg, Germany, 2009; pp. 2052–2055. [Google Scholar]
- McLaughlin, J.; McNeill, M.; Braun, B.; McCormack, P.D. Piezoelectric sensor determination of arterial pulse wave velocity. Physiol. Meas. 2003, 24, 693. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Clemente, F.; Arpaia, P.; Cimmino, P. A piezo-film-based measurement system for global haemodynamic assessment. Physiol. Meas. 2010, 31, 697. [Google Scholar] [CrossRef] [PubMed]
- Chiu, Y.Y.; Lin, W.Y.; Wang, H.Y.; Huang, S.B.; Wu, M.H. Development of a piezoelectric polyvinylidene fluoride (PVDF) polymer-based sensor patch for simultaneous heartbeat and respiration monitoring. Sens. Actuators A Phys. 2013, 189, 328–334. [Google Scholar] [CrossRef]
State | |||
---|---|---|---|
Normal pulse | 0.195 | 1:3.117:5.529 | 1:0.288:0.139 |
0.171 | 1:3.643:6.429 | 1:0.252:0.114 | |
0.196 | 1:3.235:5.059 | 1:0.358:0.096 | |
0.176 | 1:3.354:6.118 | 1:0.375:0.129 | |
0.183 | 1:3.123:5.631 | 1:0.256:0.131 | |
0.186 | 1:3.508:5.991 | 1:0.259:0.108 | |
Slippery pulse | 0.262 | 1:2.813:0 | 1:0.345:0 |
0.278 | 1:2.941:0 | 1:0.393:0 | |
0.246 | 1:1.171:0 | 1:0.363:0 | |
0.281 | 1:1.185:0 | 1:0.329:0 | |
0.274 | 1:1.026:0 | 1:0.372:0 |
State | |||
---|---|---|---|
Normal pulse | 0.918 | 0.325 | 0.198 |
0.909 | 0.364 | 0.167 | |
0.914 | 0.344 | 0.189 | |
0.917 | 0.338 | 0.188 | |
0.883 | 0.393 | 0.228 | |
0.889 | 0.386 | 0.219 | |
Slippery pulse | 0.936 | 0.307 | 0.197 |
0.928 | 0.286 | 0.181 | |
0.934 | 0.301 | 0.194 | |
0.927 | 0.279 | 0.173 | |
0.931 | 0.295 | 0.186 |
Classification Model | Kernel Function | Major Class Features | Accuracy Rate |
---|---|---|---|
NN | Linear | 0.691 | |
0.853 | |||
Rbf | 0.814 | ||
0.897 | |||
SVM | Linear | 0.856 | |
0.948 | |||
Rbf | 0.921 | ||
0.984 |
System | Clemente F | Jessica | Sun Y | Proposed |
---|---|---|---|---|
Wearable wristbands | Yes | Yes | Yes | Yes |
Type of sensors | Piezoelectricity | Piezoresistive | Piezoresistive | Piezoelectricity |
Looking for pulse | No | No | No | Yes |
Prediction and reconstruction | No | No | No | Yes |
Intelligent classification | No | No | No | Yes |
Year of publication | 2010 | 2017 | 2018 | 2023 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Liu, Y.-Y.; Lv, Y.-X.; Xue, H.-B. Intelligent Wearable Wrist Pulse Detection System Based on Piezoelectric Sensor Array. Sensors 2023, 23, 835. https://doi.org/10.3390/s23020835
Liu Y-Y, Lv Y-X, Xue H-B. Intelligent Wearable Wrist Pulse Detection System Based on Piezoelectric Sensor Array. Sensors. 2023; 23(2):835. https://doi.org/10.3390/s23020835
Chicago/Turabian StyleLiu, Yan-Yun, Yu-Xiang Lv, and Hai-Bin Xue. 2023. "Intelligent Wearable Wrist Pulse Detection System Based on Piezoelectric Sensor Array" Sensors 23, no. 2: 835. https://doi.org/10.3390/s23020835
APA StyleLiu, Y. -Y., Lv, Y. -X., & Xue, H. -B. (2023). Intelligent Wearable Wrist Pulse Detection System Based on Piezoelectric Sensor Array. Sensors, 23(2), 835. https://doi.org/10.3390/s23020835