Effect of Excitation Signal on Double-Coil Inductive Displacement Transducer

1
College of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao 266590, China
2
College of Transportation, Shandong University of Science and Technology, Qingdao 266590, China
*
Author to whom correspondence should be addressed.
Sensors 2023, 23(7), 3780; https://doi.org/10.3390/s23073780
Submission received: 22 March 2023 / Revised: 2 April 2023 / Accepted: 5 April 2023 / Published: 6 April 2023
(This article belongs to the Section Physical Sensors)

Abstract

A double-coil inductive displacement transducer is a non-contact element for measuring displacement and is widely used in large power equipment systems such as construction machinery and agricultural machinery equipment. The type of coil excitation signal has an impact on the performance of the transducer, but there is little research on this. Therefore, the influence of the coil excitation signal on transducer performance is investigated. The working principle and characteristics of the double-coil inductive displacement transducer are analyzed, and the circuit simulation model of the transducer is established. From the aspects of phase shift, linearity, and sensitivity, the effects of a sine signal, a triangle signal, and a pulse signal on the transducer are compared and analyzed. The results show that the average phase shift, linearity, and sensitivity of the sine signal were 11.53°, 1.61%, and 0.372 V/mm, respectively; the average phase shift, linearity and sensitivity of the triangular signal were 1.38°, 1.56%, and 0.300 V/mm, respectively; and the average phase shift, linearity, and sensitivity of the pulse signal were 0.73°, 1.95%, and 0.621 V/mm, respectively. It can be seen that the phase shift of a triangle signal and a pulse signal is smaller than that of a sine signal, which can result in better signal phase-locked processing. The linearity of the triangle signal is better than the sine signal, and the sensitivity of the pulse signal is better than that of the sine signal.
Keywords: double-coil inductive displacement transducer; transducer characteristics; conditioning circuit; excitation signal; linearity; sensitivity double-coil inductive displacement transducer; transducer characteristics; conditioning circuit; excitation signal; linearity; sensitivity

Share and Cite

MDPI and ACS Style

Li, Y.; Li, R.; Yang, J.; Xu, J.; Yu, X. Effect of Excitation Signal on Double-Coil Inductive Displacement Transducer. Sensors 2023, 23, 3780. https://doi.org/10.3390/s23073780

AMA Style

Li Y, Li R, Yang J, Xu J, Yu X. Effect of Excitation Signal on Double-Coil Inductive Displacement Transducer. Sensors. 2023; 23(7):3780. https://doi.org/10.3390/s23073780

Chicago/Turabian Style

Li, Yanchao, Ruichuan Li, Junru Yang, Jikang Xu, and Xiaodong Yu. 2023. "Effect of Excitation Signal on Double-Coil Inductive Displacement Transducer" Sensors 23, no. 7: 3780. https://doi.org/10.3390/s23073780

APA Style

Li, Y., Li, R., Yang, J., Xu, J., & Yu, X. (2023). Effect of Excitation Signal on Double-Coil Inductive Displacement Transducer. Sensors, 23(7), 3780. https://doi.org/10.3390/s23073780

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop