Next Issue
Volume 2, January
Previous Issue
Volume 1, March
 
 
Audiology Research is published by MDPI from Volume 10 Issue 2 (2020). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with PAGEPress.

Audiol. Res., Volume 1, Issue 2 (June 2011) – 5 articles

  • Issues are regarded as officially published after their release is announced to the table of contents alert mailing list.
  • You may sign up for e-mail alerts to receive table of contents of newly released issues.
  • PDF is the official format for papers published in both, html and pdf forms. To view the papers in pdf format, click on the "PDF Full-text" link, and use the free Adobe Reader to open them.
Order results
Result details
Select all
Export citation of selected articles as:
381 KiB  
Article
Development of Spanish Version of the LittlEARS Parental Questionnaire for Use in the United States and Latin America
by Jaclyn B. Spitzer and Jorge S. Zavala
Audiol. Res. 2011, 1(2), e31; https://doi.org/10.4081/audiores.2011.e31 - 30 Nov 2011
Cited by 3 | Viewed by 1
Abstract
The LittlEARS Auditory Questionnaire is a parent questionnaire created to assess development of age-dependent auditory behaviors of children in the pre-verbal stage. The original questionnaire was developed in Austria (in German), and is now being introduced in the United States in English. This [...] Read more.
The LittlEARS Auditory Questionnaire is a parent questionnaire created to assess development of age-dependent auditory behaviors of children in the pre-verbal stage. The original questionnaire was developed in Austria (in German), and is now being introduced in the United States in English. This study was designed to obtain normative data on a Spanish translation. Fifty parents or caregivers participated. Responses were obtained at their child’s visit to a hospital clinic or an external ambulatory site. Children ranged in age from .5 to 21.4 months (mean = 9.5 months). Parents were either Spanish monolingual or bilingual representing 5 national origins. Analyses included correlation of age with total score, and with individual questions, index of difficulty, discrimination and selectivity indices, scale analysis, split-half reliability and internal consistency. Specifically, correlation between age and number of observed behaviors was 0.927. A measure of internal consistency was high, 0.95. Results indicated that the translated LittlEARS for use with Spanish speakers is a potentially useful tool for clinicians assessing pre-verbal auditory behavior. High correlations of total score with age suggested that the questionnaire reflects a progression of auditory skills in the 0 to 24 months age group. Full article
369 KiB  
Article
Speech Perception in Noise in Normally Hearing Children: Does Binaural Frequency Modulated Fitting Provide More Benefit than Monaural Frequency Modulated Fitting?
by Siti Zamratol-Mai Sarah Mukari, Cila Umat and Ummu Athiyah Abdul Razak
Audiol. Res. 2011, 1(2), e30; https://doi.org/10.4081/audiores.2011.e30 - 10 Nov 2011
Viewed by 1
Abstract
The aim of the present study was to compare the benefit of monaural versus binaural ear-level frequency modulated (FM) fitting on speech perception in noise in children with normal hearing. Reception threshold for sentences (RTS) was measured in no-FM, monaural FM, and binaural [...] Read more.
The aim of the present study was to compare the benefit of monaural versus binaural ear-level frequency modulated (FM) fitting on speech perception in noise in children with normal hearing. Reception threshold for sentences (RTS) was measured in no-FM, monaural FM, and binaural FM conditions in 22 normally developing children with bilateral normal hearing, aged 8 to 9 years old. Data were gathered using the Pediatric Malay Hearing in Noise Test (P-MyHINT) with speech presented from front and multi-talker babble presented from 90º, 180º, 270º azimuths in a sound treated booth. The results revealed that the use of either monaural or binaural ear level FM receivers provided significantly better mean RTSs than the no-FM condition (P<0.001). However, binaural FM did not produce a significantly greater benefit in mean RTS than monaural fitting. The benefit of binaural over monaural FM varies across individuals; while binaural fitting provided better RTSs in about 50% of study subjects, there were those in whom binaural fitting resulted in either deterioration or no additional improvement compared to monaural FM fitting. The present study suggests that the use of monaural ear-level FM receivers in children with normal hearing might provide similar benefit as binaural use. Individual subjects’ variations of binaural FM benefit over monaural FM suggests that the decision to employ monaural or binaural fitting should be individualized. It should be noted however, that the current study recruits typically developing normal hearing children. Future studies involving normal hearing children with high risk of having difficulty listening in noise is indicated to see if similar findings are obtained. Full article
703 KiB  
Article
Distortion-Product Otoacoustic Emissions: Body Position Effects with Simultaneous Presentation of Tone Pairs
by Samuel R. Atcherson and Amy Mattheis
Audiol. Res. 2011, 1(2), e29; https://doi.org/10.4081/audiores.2011.e29 - 9 Nov 2011
Cited by 1 | Viewed by 1
Abstract
This study examined the effect of three different body positions on distortion-product otoacoustic emission (DPOAE) amplitude and noise levels with multiple primary tone pairs simultaneously-presented to 36 normal-hearing female human adults. Other studies have demonstrated that the simultaneously presented tone pairs method shows [...] Read more.
This study examined the effect of three different body positions on distortion-product otoacoustic emission (DPOAE) amplitude and noise levels with multiple primary tone pairs simultaneously-presented to 36 normal-hearing female human adults. Other studies have demonstrated that the simultaneously presented tone pairs method shows clinical promise as a screener, but the sequential method remains in widespread clinical use. Postural changes have been suggested to have an effect not only on DPOAEs, but also transient-evoked OAEs and stimulus- frequency OAEs. DPOAE amplitude and noise levels were recorded in seated, supine, and side-lying positions to the following order of simultaneously-presented tone pairs relative to the f2 frequencies: 1187, 2375, and 4812 Hz; 1500, 3000, and 6062 Hz; and 1875, 3812, and 7625 Hz. No DPOAE could be detected reliably at 7625 Hz as result of poor signal-to-noise ratio. For remaining DPOAEs, statistical analyses revealed that amplitudes were not significantly different among the three body positions. However, at 1500 Hz and below, body position did have a statistically significant effect on noise levels though they are likely clinically negligible. Except at 7625 Hz, results suggest that DPOAEs recorded using a simultaneously presented tone pairs appear to be comparably recorded regardless of an individual’s body position. Full article
414 KiB  
Case Report
Simultaneous Vibrant Soundbridge Implantation and 2nd Stage Auricular Reconstruction for Microtia with Aural Atresia
by Lynne Hsueh Yee Lim, Ling Xiang, Jocelynne del Prado, Ee Ling Chin and Millo Achille Beltrame
Audiol. Res. 2011, 1(2), e28; https://doi.org/10.4081/audiores.2011.e28 - 23 Sep 2011
Cited by 2 | Viewed by 1
Abstract
Aural atresia and severe microtia are associated malformations that result in problems with hearing and cosmesis, associated speech and language difficulties and diminished self-esteem. In cases where middle ear ossiculoplasty and aural atresia canalplasty are expected to give poor hearing outcomes that would [...] Read more.
Aural atresia and severe microtia are associated malformations that result in problems with hearing and cosmesis, associated speech and language difficulties and diminished self-esteem. In cases where middle ear ossiculoplasty and aural atresia canalplasty are expected to give poor hearing outcomes that would eventually require the use of hearing aids, bone anchored hearing aids or active middle ear implants may be better options. This case report describes a simultaneous Vibrant Soundbridge implantation and 2nd stage auricular reconstruction with rib graft cartilage for an 11-year-old boy with grade III microtia and aural atresia 8 months after the 1st stage reconstruction. Audiometric results of the Vibrant Soundbridge aided ear were comparable to that of the contralateral hearing aid aided ear. Full article
518 KiB  
Article
Spectrum Resolving Power of Hearing: Measurements, Baselines, and Influence of Maskers
by Alexander Ya. Supin
Audiol. Res. 2011, 1(2), e27; https://doi.org/10.4081/audiores.2011.e27 - 15 Jun 2011
Cited by 3 | Viewed by 1
Abstract
Contemporary methods of measurement of frequency tuning in the auditory system are reviewed. Most of them are based on the frequency-selective masking paradigm and require multi-point measurements (a number of masked thresholds should be measured to obtain a single frequency-tuning estimate). Therefore, they [...] Read more.
Contemporary methods of measurement of frequency tuning in the auditory system are reviewed. Most of them are based on the frequency-selective masking paradigm and require multi-point measurements (a number of masked thresholds should be measured to obtain a single frequency-tuning estimate). Therefore, they are rarely used for practical needs. As an alternative approach, frequency-selective properties of the auditory system may be investigated using probes with complex frequency spectrum patterns, in particular, rippled noise that is characterized by a spectrum with periodically alternating maxima and minima. The maximal ripple density discriminated by the auditory system is a convenient measure of the spectrum resolving power (SRP). To find the highest resolvable ripple density, a phase-reversal test has been suggested. Using this technique, normal SRP, its dependence on probe center frequency, spectrum contrast, and probe level were measured. The results were not entirely predictable by frequency-tuning data obtained by masking methods. SRP is influenced by maskers, with on- and off-frequency maskers influencing SRP very differently. Dichotic separation of the probe and masker results in almost complete release of SRP from influence of maskers. Full article
Previous Issue
Next Issue
Back to TopTop