Case Report

A Case of Shunting Postoperative Patent Foramen Ovale under Mechanical Ventilation Controlled by Different Ventilator Settings

by
Claudio Pragliola
1,*,
Sara Di Michele
2 and
Domenico Galzerano
1
1
The Heart Centre, King Faisal Specialist Hospital and Research Centre, Ryadh, Saudi Arabia
2
Department of Cardiovascular, Respiratory, Nephrological, Anaesthetic and Geriatric Sciences, La Sapienza University, Roma, Italy
*
Author to whom correspondence should be addressed.
Clin. Pract. 2017, 7(3), 969; https://doi.org/10.4081/cp.2017.969
Submission received: 3 April 2017 / Revised: 7 June 2017 / Accepted: 19 July 2017 / Published: 4 August 2017

Abstract

A 56-year old male with ischemic heart disease and an unremarkable preoperative echocardiogram underwent surgical coronary revascularization. An intraoperative post pump trans-esophageal echocardiogram (TOE) performed while the patient was being ventilated at a positive end expiratory pressure (PEEP) of 8 cm H2O demonstrated a right to left interatrial shunt across a patent foramen ovale (PFO). Whereas oxygen saturation was normal, a reduction of the PEEP to 3 cm H2O led to the complete resolution of the shunt with no change in arterial blood gases. Attempts to increase the PEEP level above 3 mmHg resulted in recurrence of the interatrial shunt. The remaining of the TEE was unremarkable. Mechanical ventilation, particularly with PEEP, causes an increase in intrathoracic pressure. The resulting rise in right atrial pressure, mostly during inspiration, may unveil and pop open an unrecognized PFO, thus provoking a right to left shunt across a seemingly intact interatrial septum. This phenomenon increases the risk of paradoxical embolism and can lead to hypoxemia. The immediate management would be to adjust the ventilatory settings to a lower PEEP level. A routine search for a PFO should be performed in ventilated patients who undergo a TEE.
Keywords: mechanical ventilation; patent foramen ovale; positive end expiratory pressure; transesophageal echocardiography mechanical ventilation; patent foramen ovale; positive end expiratory pressure; transesophageal echocardiography

Share and Cite

MDPI and ACS Style

Pragliola, C.; Di Michele, S.; Galzerano, D. A Case of Shunting Postoperative Patent Foramen Ovale under Mechanical Ventilation Controlled by Different Ventilator Settings. Clin. Pract. 2017, 7, 969. https://doi.org/10.4081/cp.2017.969

AMA Style

Pragliola C, Di Michele S, Galzerano D. A Case of Shunting Postoperative Patent Foramen Ovale under Mechanical Ventilation Controlled by Different Ventilator Settings. Clinics and Practice. 2017; 7(3):969. https://doi.org/10.4081/cp.2017.969

Chicago/Turabian Style

Pragliola, Claudio, Sara Di Michele, and Domenico Galzerano. 2017. "A Case of Shunting Postoperative Patent Foramen Ovale under Mechanical Ventilation Controlled by Different Ventilator Settings" Clinics and Practice 7, no. 3: 969. https://doi.org/10.4081/cp.2017.969

Article Metrics

Back to TopTop