Next Article in Journal
Recent Progress in the Preparation Technologies for Micro Metal Coils
Previous Article in Journal
A Cost-Effective Nucleic Acid Detection System Using a Portable Microscopic Device
Previous Article in Special Issue
Investigations on 2Cr13 Stainless Valves after Dry-Type Laser Degumming
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Analytical Model for the Depth Progress during Laser Micromachining of V-Shaped Grooves

Institut für Strahlwerkzeuge (IFSW), University of Stuttgart, Pfaffenwaldring 43, 70569 Stuttgart, Germany
*
Author to whom correspondence should be addressed.
Micromachines 2022, 13(6), 870; https://doi.org/10.3390/mi13060870
Submission received: 8 May 2022 / Revised: 28 May 2022 / Accepted: 29 May 2022 / Published: 31 May 2022
(This article belongs to the Special Issue Laser Micromachining)

Abstract

:
An analytical model is presented that allows predicting the progress and the final depth obtained by laser micromachining of grooves in metals with ultrashort laser pulses. The model assumes that micromachined grooves feature a V-shaped geometry and that the fluence absorbed along the walls is distributed with a linear increase from the edge to the tip of the groove. The depth progress of the processed groove is recursively calculated based on the depth increments induced by successive scans of the laser beam along the groove. The experimental validation confirms the model and its assumptions for micromachining of grooves in a Ti-alloy with femtosecond pulses and different pulse energies, repetition rates, scanning speeds and number of scans.

Graphical Abstract

1. Introduction

Laser micromachining of grooves with ultrashort laser pulses is a versatile process that can be applied for various applications, such as cutting through thin metal foils [1], dicing silicon wafers [2], engraving implants made of titanium alloy to enhance osseointegration [3] or engraving cutting tools to reduce the force and friction in mechanical machining of aluminum [4]. In micromachining processes with pulsed lasers, a relative movement between the laser beam and the workpiece is created either by deflecting the laser beam over the processed surface by means of a scanner or by moving the workpiece past the static beam by means of a linear axis. In both cases, multiple scans over the same contour are typically performed to fabricate grooves with a required depth. The dimensions of the micromachined grooves, i.e., the depth and width or their aspect ratio (depth/width), have a major influence on the performance of the respective application: A complete cut through the sample is required in the cutting of thin metal sheets [1]. In open microfluidic systems, a higher flow velocity of liquids is achieved for grooves with a higher aspect ratio [5,6]. Grooves with higher aspect ratios also enhanced the performance of engraved cutting tools in mechanical machining [4].
The laser micromachined grooves with depths of a few tens up to several hundreds of micrometers typically feature a V-shaped geometry in metals [7,8], semiconductors [2,9], dielectrics [10] and polymers [11]. The resulting width of the grooves mainly depends on the diameter of the laser beam, the incident peak fluence and the material-specific ablation threshold [12]. Experimental results revealed the influence of various processing parameters on the resulting depth of a micromachined groove, such as the pulse energy or the irradiated peak fluence, the scanning speed, the number of scans over the surface [2,8,9] and the ablation threshold [12]. The groove’s depth can be increased by multiple scans, whereas high pulse energies [2,8] and low scanning speeds [9] result in a higher increase in the depth for each scan. The progress of the depth of micromachined grooves exhibited a linear correlation with the number of scans for cutting through thin metal foils with a thickness of up to 50 µm [1] and for micromachining of shallow grooves with a depth of up to a few tens of micrometers in semiconductors [9]. A constant deepening rate of laser-processed grooves was achieved up to an aspect ratio (depth/width) of approximately 1.5 [6], which corresponds to the phase of constant depth progress observed in areal micromachining of metals [13] and silicon [14], where the aspect ratio is typically < 1. The depth progress gradually slows down with increasing depth of the groove [6,8,9], reaching a limit when the absorbed fluence is reduced to the value of the ablation threshold everywhere on the walls of the groove [2]. This behavior corresponds to the one found for percussion drilling of microholes, where a decreasing rate of the depth progress was observed with the increasing number of applied pulses, which finally stagnated at the maximum reachable depth [15,16]. It is not energy-efficient to process until this maximum depth is reached since the rate of the depth progress decreases despite the constant applied average power.
The in situ measurement of the current depth during processing has already been demonstrated using optical coherence tomography for percussion drilling of microholes [15,17] and for areal micromachining [18,19]. This approach is also suitable for the production of grooves, as shown in [6] for groove depths up to 500 µm. The prediction of the reachable depth of the grooves or the estimate of the rate of the depth progress during laser micromachining, which would allow for the design of an efficient and productive machining process, has proven to be difficult due to the influence and interplay of various laser parameters, scanning parameters and material properties, including the groove’s depth itself. A numerical model for the calculation of the groove geometry is proposed in [20], but the model does not consider the increased absorptance in V-shaped grooves that is caused by multiple reflections, which were observed in raytracing simulations [21].
A simplified analytical model for the prediction of the depth progress in laser machining of V-shaped grooves with ultrashort laser pulses is therefore introduced in the following section. The model was experimentally verified for the case of laser micromachining of grooves with a depth of up to 624 38 + 28 µm in the Ti-alloy Ti6Al4V with different pulse energies, repetition rates, scanning speeds and number of scans.

2. Analytical Model for the Prediction of the Depth and Width of Laser Micromachined Grooves

An analytical, recursive model for the calculation of the depth progress of laser-processed V-shaped grooves in metals can be derived in analogy to the model for percussion drilling of conical microholes as presented in [15]. Figure 1 illustrates the assumptions made for the model as seen by the cross section in the yz-plane perpendicular to the scanning direction x.
The pulses of a Gaussian laser beam are irradiated onto the metal sample (the grey hatched cross section) at normal incidence (i.e., in the z-direction). At the surface of the workpiece, the transversal distribution of the incident fluence (red curve) is given by
ϕ ( x , y ) = ϕ 0 exp ( 2 ( x x C ) 2 + ( y y C ) 2 w 0 2 ) ,
where x − xC and y − yC are the distances from the centre of the laser beam located at (xC, yC), w0 is the beam radius and ϕ0 denotes the peak fluence, which is given by
ϕ 0 = 2 E P π w 0 2 ,
where EP is the pulse energy. At normal incidence, material removal by ablation on the surface occurs when the locally absorbed fluence A ϕ ( y ) , where A is the material-specific absorptivity at the wavelength of the incident radiation, exceeds the value
ϕ th = l E h V
of the ablation threshold, where lE denotes the effective penetration depth of the absorbed energy density and hV denotes the volume-specific enthalpy required for heating and complete vaporization of the material. The effective penetration depth lE is dominated either by the optical penetration depth or by the electron heat diffusion length, depending on the peak fluence of the incident radiation [22]. Additionally, lE and thus ϕth decrease with increasing number of pulses applied to the surface [23] due to the so-called incubation effect [24]. The incubation effect saturates after about 100 pulses, whereupon the effective penetration depth and the ablation threshold are not significantly decreased further by additional pulses [23]. For the sake of simplicity, the energy penetration depth lE and thus the ablation threshold ϕth are assumed to be constant over the entire process for the presented analytical model. The error caused by this simplification during the first 100 pulses is negligible as typically, more than several thousands of pulses are applied to each location for the production of laser machined grooves.
The width of the groove dG resulting from material removal corresponds to two times the ablation radius rabl and is calculated by [15]
d G = 2 r abl = 2 w 0 1 2 ln ( A ϕ 0 ϕ th ) ,
since no ablation can occur at the locations | y | > r abl where the fluence absorbed on the surface of the workpiece is lower than the ablation threshold. It is implicitly premised here that the spatial overlap of consecutive pulses along the scan path in the x-direction is sufficiently large to ensure a constant width of the groove. The spatial pulse overlap Ωx is defined by
Ω x = 1 δ x 2 w 0 ,
where
δ x = v x f rep
denotes the spatial offset between the impact locations of two consecutive pulses, vx is the scanning speed and frep is the pulse repetition rate. A constant groove width dG is typically achieved with a spatial pulse overlap ranging from 30% to 95% [2].
The proposed recursive model is based on the assumption that the groove depth zG,n after n ∈ 1,2,…N scans can be calculated by
z G , n = z G , n 1 + z S , n ,
where zG,n − 1 denotes the groove depth after n − 1 scans and zS,n denotes the depth ablated by the nth scan (cf. Figure 1). The overall absorptance ηA resulting from multiple reflections inside the V-shaped groove may be calculated assuming specular reflections of a ray, which is incident in z-direction and is found to be [25]
η A ( d G , z G , n 1 ) = 1 ( 1 A ) N R ( d G , z G , n 1 ) ,
where NR denotes the number of reflections of the ray until it leaves the groove again. This number of reflections depends on the aspect ratio of the V-shaped groove and is given by [25]
N R ( d G , z G , n 1 ) = π 2 arctan ( d G 2 z G , n 1 ) 1 2 ,
where is the rounding up function.
The energy dEA,n(xj) absorbed from one single pulse of a Gaussian laser beam during the nth scan along the groove at the location x in a stripe with the width dx inside the groove between the edges at y = ±dG/2 amounts to
d E A , n , j ( x ) = d x d G 2 d G 2 η A ( d G , z G , n 1 ) ϕ 0 exp ( 2 ( x x C , j ) 2 + y 2 w 0 2 ) d y ,
where x C , j = j δ x is the location of the beam axis along the x-axis at the time at which the jth pulse hits the workpiece and where j ∈ ℤ and yC was set to zero for the beam, which is centred on the groove.
The overall absorptance ηA(dG, zG,n − 1) only defines the amount of energy dEA,n,j(x) absorbed in the groove but does not specify the transversal distribution of the fluence in the yz-plane (cf. Figure 1). As shown by raytracing simulations of V-shaped capillaries in [21], the effect of multiple reflections causes an elevated absorbed fluence near the tip of the groove. As a simple approximation for the transversal distribution of the absorbed fluence in the groove, it is assumed in the following that the absorbed fluence linearly increases with the depth along the sidewalls of the V-shaped groove in the yz-plane. In analogy to the model presented for percussion drilling [15] and assuming that multiple reflections only occur normal to the axis of the groove, the distribution of the absorbed fluence at a given location x along the groove is assumed to start with ϕth at the edge of the groove (at y = ±dG/2) and end with ϕtip,n,j(x) at the tip of the groove (y = yC = 0). With this assumption, the energy dEA,n,j(x) absorbed at the location x from a single pulse j in a stripe of width dx amounts to
d E A , n , j ( x ) = d x d G 2 + 4 z G , n 1 2 ( ϕ th + ϕ tip , n , j ( x ) 2 ) ,
where d G 2 + 4 z G , n 1 2 is the length of the two sidewalls together measured in the yz-plane (cf. Figure 1). As both Equations (10) and (11) describe the same energy, it follows that
d x d G 2 + 4 z G , n 1 2 ( ϕ th + ϕ tip , n , j ( x ) 2 ) = d x η A ( d G , z G , n 1 ) ϕ 0 exp ( 2 ( x x C , j ) 2 w 0 2 ) d G 2 d G 2 exp ( 2 y 2 w 0 2 ) d y .
Inserting Equation (2) and replacing the integral with π 2 w 0 erf ( d G 2 w 0 ) , where erf is the well-known error function, one finds that the fluence deposited at the tip of the groove with the depth zG,n − 1 at the location x by the jth pulse during the nth scan is given by
ϕ tip , n , j ( x ) = 2 2 η A ( d G , z G , n 1 ) E P π w 0 d G 2 + 4 z G , n 1 2 erf ( d G 2 w 0 ) exp ( 2 ( x x C , j ) 2 w 0 2 ) ϕ th .
Figure 2 shows a sequence of distributions of the fluence ϕtip,n,j(x) with a spatial offset of δx each absorbed at the tip of the groove around an arbitrary point x0. For the sake of clarity, the figure is divided into two parts showing the pulses with j ≤ 0 in Figure 2a) and the pulses with j ≥ 0 in Figure 2b). The pulses are numbered in such a way that the beam axis coincides with x0 at the moment when the 0th pulse hits the workpiece (xC,0 = x0). Considering this diagram, it becomes evident that from the perspective of a point (x = x0, y = 0) located at x0 somewhere along the centre line of the groove, the individual pulses of a scan can only contribute to the ablation of the groove at this point x0 as long as the fluence absorbed at the tip ϕtip,n,j(x0) > ϕth exceeds the ablation threshold ϕth. The fluence that is absorbed at the tip of the groove from each of the pulses j of one scan (with j = …, −3, −2, −1, 0, 1, 2, 3, …) at the location x = x0 is given by the intersection of the fluence distribution ϕtip,n,j(x) with the ordinate at x = x0, as indicated by the colored small arrows in Figure 2.
In the example depicted in Figure 2, only the pulses from j = −2 to j = 2 contribute to material ablation at (x = x0, y = 0), as only their fluences ϕtip,n,j(x0) exceed the ablation threshold ϕth, whose value is indicated by the black dotted line. The intersection ϕ tip , n , j ( x = j abl , n δ x ) = ϕ th of the fluence distribution ϕtip,n,j(x) with the ablation threshold ϕth determines the maximum number of pulses jabl,n contributing to ablation in this direction. Using Equation (12) and solving for jabl,n yields
j abl , n = w 0 δ x 1 2 ln ( 2 η A ( d G , z G , n 1 ) E P erf ( d G 2 w 0 ) ϕ th π w 0 d G 2 + 4 z G , n 1 2 ) .
As a result, the depth ablated by the nth scan zS,n as seen by the spot x = x0 located on the centre line of the groove corresponds to the accumulated depth ablated by the pulses j = j abl , n to j = j abl , n and can be calculated by
z S , n = j = j abl , n j abl , n z P , n , j ( x ) ,
where means rounding off and zP,n,j(x) denotes the depth ablated by the pulse j during the nth scan. According to the logarithmic ablation law [23,26], the depth increment ablated by a single pulse is given by
z P , n , j ( x ) = l E ln ( ϕ tip , n , j ( x ) ϕ th ) .
In the present model, a constant absorptance ηA (dG, zG,n − 1) as given by Equations (8) and (9) is assumed during one scan over the groove. This induces a negligible error since ηA changes very slowly with an increasing number n of scans as long as zS,n << dG, which is typically the case in micromachining processes with a reasonable pulse overlap Ωx in the range of 30–95%.
With the above equations, the progress of the increasing groove depth zG,n can be recursively calculated as a function of the number n of scans. A useful way to proceed is by starting with the calculation of the constant parameters that are not affected by the recursive calculation, such as the spatial offset δx between the impact locations of two consecutive pulses using Equation (6). Furthermore, the peak fluence ϕ0 and ablation threshold ϕth can be calculated with Equations (2) and (3), respectively, in order to determine the width of the groove dG using Equation (4). With the first scan (n = 1) at the beginning of the recursive calculation, a very small value should be chosen for the initial groove depth, e.g., zG,0 = 1 nm (zG,0 ≠ 0), so as not to divide by 0 in the subsequent calculation of the absorptance ηA (dG, zG,0) in Equations (8) and (9). Then, the maximum number of pulses jabl,1 contributing to ablation in each direction is calculated using Equation (13), followed by the calculation of the fluence ϕtip,1,j(x) deposited at the tip of the groove with Equation (12) for each contributing pulse j during this first scan. The depth increment zP,1,j(x) ablated by each pulse j is calculated using Equation (15) and accumulated according to Equation (14). Then, the accumulated depth of the first scan zS,1 is added to the initial groove depth zG,0 as given by Equation (7). The calculation of the absorptance ηA (dG, zG,1) of the groove with increased depth zG,1 starts the second loop of the recursive calculation. This procedure must be repeated n times to receive the groove depth zG,n after micromachining with n scans.
The absorbed fluence ϕtip,n,j(x) at the tip of the groove decreases with increasing groove depth due to the increasing length of the sidewalls d G 2 + 4 z G , n 1 2 . This reduction is partially compensated by an increased absorptance ηA (dG, zG,n−1) due to the increasing number NR of reflections within the groove (cf. Equations (8) and (9)). The maximum attainable groove depth zG, obtained after n → ∞ scans is reached when the fluence ϕtip,n,j(x = xC) at the tip of the V-shaped groove converges to the value of the ablation threshold ϕth. The maximum groove depth zG, can therefore be found with Equation (12) by setting ϕtip,n,j(x = xC) = ϕth, and solving for zG,, which yields
z G , = η 2 E P 2 2 π w 0 2 ϕ th 2 ( erf ( d G 2 w 0 ) ) 2 d G 2 4 ,
where η = ηA (dG, zG,−1) denotes the absorptance of a groove micromachined with ∞−1 scans. As the absorptance, in turn, depends on the groove depth zG,n−1 (cf. Equations (8) and (9)), the maximum groove depth zG,∞ cannot be calculated directly but has to be found by a recursive calculation using Equation (7). Assuming a high aspect ratio zG,∞/dG of the final groove, the absorptance can, however, be approximated to be η ≈ 1, and the maximum achievable groove depth zG,∞ obtained with a given parameter set can directly be estimated using Equation (16) by setting η = 1. Equation (16) also shows that the maximum achievable groove depth does neither depend on the repetition rate frep nor on the scanning parameters such as the scanning speed vx and that—for a given beam radius w0 and with the material-specific value of ϕth—it can only by increased by increasing the pulse energy EP.
It is noted that the model for the calculation of the depth progress presented in this section only requires five generally known laser and scanning parameters, namely the pulse energy EP, the repetition rate frep, the radius w0 of the laser beam, the scanning speed vx, and the number of scans n, as well as the three material parameters, absorptivity A, energy penetration depth lE, and the enthalpy hV for heating and complete vaporization of the material.

3. Experimental Verification of the Analytical Model

The model for the prediction of the depth and width of laser micromachined grooves derived in the previous section was compared to experimental results obtained by micromachining samples with a size of 50 × 50 mm² and a thickness of 1 mm made of Ti6Al4V (ASTM Grade 5), a Ti-alloy often used in the aerospace industry and for biomechanical applications due to the high specific strength, corrosion resistance and biocompatibility. The ultrafast laser system Pharos from Light Conversion with a wavelength of 1030 nm was used for micromachining. The laser emitted pulses with a pulse duration of 260 fs. The circularly polarized laser beam with a Gaussian intensity distribution had a beam propagation factor of M² < 1.3. The beam was scanned over the surface of the samples by means of a Galvanometer-Scanner (Scanlab, intelliSCAN 30) and was focused by an F-Theta lens (Sill Optics, S4LFT1330/328) with a focal length of 340 mm, resulting in a focal radius of w0 = 55 ± 5 µm. The focus position was always set on the surface of the samples. Grooves with a length of 10–35 mm were micromachined in the Ti-samples with different pulse energies EP, repetition rates frep, scanning speeds vx and number of scans n, as summarized in Table 1. The spatial offset δx of the impact locations of two consecutive pulses and the corresponding pulse overlap Ωx were calculated according to Equation (6) and Equation (5), respectively.
After micromachining, the samples were cut perpendicular to the grooves (yz-plane), and cross sections were prepared by grinding and polishing in order to investigate the shape of the grooves and measure their depth and width using an optical microscope (Leica, DM6 M). Figure 3 shows the cross sections obtained with the parameter set P1 (cf. Table 1).
Five grooves were machined with each of the parameter sets listed in Table 1. The measured values of the depth and width of the five grooves from each parameter set were used for averaging and calculating the maximum and minimum deviation. As expected from theory, the width of the groove remained constant at the value of dG = 138 5 + 8 μm independent of the number of scans, which is also in good agreement with the results shown in [2]. The V-shape clearly dominates the shape of the shown grooves for n ≥ 800. Deviations from the V-shape can be seen for n = 300 and n = 600 due to rough structures at the bottom of the grooves. Bending of the tip of the groove occurred for n = 10,000, which was also observed in [8] for micromachining of deep grooves in a Ni-alloy and drilling of deep microholes in CVD diamond [27]. The cause for the bending of the tip has not been conclusively clarified yet, but a polarization-dependent behaviour was found in [27].
The material parameters for titanium published in [28,29] were used for the calculation of the volume-specific enthalpy of hV = 47.1 J/mm³, which is required to heat and vaporize the material. The values are listed in Table 2. The absorptivity of titanium at normal incidence and at a wavelength of 1030 nm was set to A = 0.51 [30]. The effective penetration depth was used as a fit parameter. A good agreement between the calculated and the experimental results was found with lE = 30 nm. This value corresponds to an absorbed threshold fluence of ϕth = 0.14 J/cm² (cf. Equation (3)). The fitted value of lE = 30 nm is consistent with experimentally determined values of the optical penetration depth of 26 nm for Ti6Al4V [31] and 30 nm for titanium [22].
The groove widths are given by Equation (4) for the peak fluences of 3.81 J/cm² (P1) and 1.45 J/cm² (P2) yield dG = 126 µm and dG = 100 µm, respectively. The experimentally determined widths of 138 5 + 8 µm (P1) and 113 5 + 4  µm (P2) are slightly larger. The moderate deviations of less than 15% may be explained by the fact that no incubation effect is taken into account in the model.
The progress of the groove depth zG,n as a function of the number n of scans was recursively calculated as described above. The calculations are compared to the experimental results in Figure 4. The groove depths as calculated by the model derived in the previous section and as measured from the cross sections for the different parameter combinations P1–P5 (cf. Table 1) are represented in different colors with dotted lines and data points, respectively. The value of the data points corresponds to the average values measured from up to five grooves micromachined with identical parameters. The error bars represent the deviation to the maximum and minimum measured groove depth of each parameter set.
Up to an aspect ratio (depth/width) of zG/dG ≈ 1.5, the measured groove depth increases almost linearly with the number of scans. The progress of the depth is found to slow down for aspect ratios beyond zG/dG > 1.5. At constant repetition rate frep and scanning speed vx, higher depth progress and deeper grooves were achieved for higher pulse energies (cf. P1 and P2). For constant pulse energy EP and constant pulse overlap Ωx, the groove depth as a function of number of scans is similar (cf. P2 and P3). However, the net processing time is divided in half for P3 in comparison to P2 due to double the scanning speed vx at a twofold repetition rate frep. At constant pulse energy EP and constant repetition rate frep, higher depth progress is achieved with lower scanning speeds vx (cf. P3, P4 and P5). The relations observed in this work regarding the depth progress in micromachining of grooves in Ti6Al4V confirm the observations made for semiconductors in [2,9] and for a Ni-alloy in [8]: The groove depth increases with increasing number of scans, and at high pulse energies and low scanning speeds, a greater increase in depth was observed with each scan. The maximum groove depth of 624 38 + 28 µm was achieved with the highest investigated pulse energy EP = 181 µJ and the highest number of scans n = 10,000 for this parameter combination (P1). The maximum measured groove depth for a constant pulse energy EP = 69 µJ and different scanning parameters (from P2 to P5) is in the range of 306 14 + 13  µm.
The groove depths as calculated by the model (dotted lines, “Model”) and as measured by the cross sections with the optical microscope (data points, “Measured”) are in very good agreement for the different parameter combinations and for the different number of scans. The depth progress predicted by the model decreases with increasing number of scans and stagnates when the fluence in the tip converges the ablation threshold, which corresponds well with the results from [2]. As a result, the calculated groove depths as a function of the number of scans for a constant pulse energy EP = 69 µJ, but micromachined with different scanning parameters (from P2 to P5) converge to the same maximum groove depth, which agrees well with the theoretical prediction of the model of 326 µm calculated by Equation (16) for η = 1. Deviations from calculation and measurement might result from uncertainties regarding the material parameters used for the calculation, in particular the fitted value for the effective penetration depth lE, or from deviations of the assumed ideal V-shape, as shown before in Figure 3 for n = 10,000, with the bending of the tip. Complete vaporization is assumed in the proposed analytical model, whereas additional effects such as melting and spallation can cause a deviating process enthalpy and thus a different ablation rate [32].
Nevertheless, for a broad range of laser and scanning parameters, the V-shape and calculated groove dimensions by the model correspond to the shape and groove dimensions as measured by the cross sections shown in Figure 5 for some of the grooves from P1 to P5 and different number of scans. The colored triangles were dimensioned according to the groove depth zG and groove width dG, as calculated by the model derived in the previous section.
Knowing the laser parameters EP and frep, the scanning speed vx and beam radius w0, and the three material parameters A, lE and hV, the model allows for the prediction of the groove dimensions as a function of the number of scans n and maximum achievable groove depth.

4. Conclusions

An analytical model for the prediction of the depth and width of V-shaped grooves in metals micromachined with ultrashort laser pulses was derived. The model predicts the progress of the micromachining depth for V-shaped grooves in a Ti-alloy with ultrashort laser pulses as a function of laser parameters, scanning parameters and material parameters. The corresponding assumptions for the model were experimentally validated for different pulse energies, repetition rates, scanning speeds and number of scans using cross sections and optical microscopy. The analytical model derived in our paper provides a useful tool for the estimation of the groove dimensions, process windows of micromachining with high depth progress and the maximum achievable groove depth.

Author Contributions

Conceptualization, D.H.; Investigation, D.H.; Methodology, D.H., R.W. and T.G.; Validation, D.H.; Writing—Original Draft Preparation, D.H.; Writing—Review and Editing, T.G. All authors have read and agreed to the published version of the manuscript.

Funding

This work was funded by the Federal Ministry for Economic Affairs and Climate Action (BMWK) in the frame of the project “BionicTools” (03EN4007G).

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

The authors wish to thank Ulrich Höchner and Light Conversion for providing the ultrafast laser Pharos. Furthermore, the authors wish to thank Kim Glumann and Nils Ensminger for the support with the experiments and Liane Hoster for the support with the SEM images.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Bruneel, D.; Matras, G.; Le Harzic, R.; Huot, N.; König, K.; Audouard, E. Micromachining of metals with ultra-short Ti-Sapphire lasers: Prediction and optimization of the processing time. Opt. Lasers Eng. 2010, 48, 268–271. [Google Scholar] [CrossRef]
  2. Fornaroli, C.; Holtkamp, J.; Gillner, A. Dicing of thin Si wafers with a picosecond laser ablation process. In International Congress on Applications of Lasers & Electro-Optics; Laser Institute of America: Orlando, FL, USA, 2013; pp. 667–671. [Google Scholar]
  3. Wang, C.; Hu, H.; Li, Z.; Shen, Y.; Xu, Y.; Zhang, G.; Zeng, X.; Deng, J.; Zhao, S.; Ren, T.; et al. Enhanced Osseointegration of Titanium Alloy Implants with Laser Microgrooved Surfaces and Graphene Oxide Coating. ACS Appl. Mater. Interfaces 2019, 11, 39470–39483. [Google Scholar] [CrossRef] [PubMed]
  4. Esch, P.; Klocke, F.; Bauernhansl, T.; Schneider, M. Methodic development of laser micro structured cutting tools with microscale textures for AW7075 aluminum alloy using a Plackett–Burman screening design. CIRP J. Manuf. Sci. Technol. 2021, 32, 188–195. [Google Scholar] [CrossRef]
  5. Berthier, J.; Gosselin, D.; Villard, N.; Pudda, C.; Boizot, F.; Costa, G.; Delapierre, G. The Dynamics of Spontaneous Capillary Flow in Confined and Open Microchannels. Sens. Transducers 2014, 183, 123–128. [Google Scholar]
  6. Holder, D.; Weber, R.; Graf, T. Laser Micromachining of V-Shaped Grooves on Ti-6Al-4V with Ultrashort Laser Pulses for Passive Directional Transport of Fluids; International Congress on Applications of Lasers & Electro-Optics (ICALEO): Orlando, FL, USA, 2021. [Google Scholar]
  7. Salama, A.; Yan, Y.; Li, L.; Mativenga, P.; Whitehead, D.; Sabli, A. Understanding the self-limiting effect in picosecond laser single and multiple parallel pass drilling/machining of CFRP composite and mild steel. Mater. Des. 2016, 107, 461–469. [Google Scholar] [CrossRef]
  8. Zhao, W.; Wang, L.; Yu, Z.; Chen, J.; Yang, J. A processing technology of grooves by picosecond ultrashort pulse laser in Ni alloy: Enhancing efficiency and quality. Opt. Laser Technol. 2019, 111, 214–221. [Google Scholar] [CrossRef]
  9. Borowiec, A.; Haugen, H.K. Femtosecond laser micromachining of grooves in indium phosphide. Appl. Phys. A 2004, 79, 521–529. [Google Scholar] [CrossRef]
  10. Butkus, S.; Alesenkov, A.; Paipulas, D.; Gaizauskas, E.; Melninkaitis, A.; Kaskelyte, D.; Barkauskas, M.; Sirutkaitis, V. Analysis of the Micromachining Process of Dielectric and Metallic Substrates Immersed in Water with Femtosecond Pulses. Micromachines 2015, 6, 2010–2022. [Google Scholar] [CrossRef] [Green Version]
  11. Stępak, B.D.; Antończak, A.J.; Szustakiewicz, K. Optimization of Femtosecond Laser Micromachining of Polylactide and PLLA/HAp Composite; Klotzbach, U., Washio, K., Kling, R., Eds.; Laser-based Micro- and Nanoprocessing XII; SPIE: Bellingham, DC, USA, 2018; p. 70. [Google Scholar]
  12. Furmanski, J.; Rubenchik, A.M.; Shirk, M.D.; Stuart, B.C. Deterministic processing of alumina with ultrashort laser pulses. J. Appl. Phys. 2007, 102, 073112. [Google Scholar] [CrossRef] [Green Version]
  13. Cheng, J.; Perrie, W.; Edwardson, S.P.; Fearon, E.; Dearden, G.; Watkins, K.G. Effects of laser operating parameters on metals micromachining with ultrafast lasers. Appl. Surf. Sci. 2009, 256, 1514–1520. [Google Scholar] [CrossRef]
  14. Holder, D.; Weber, R.; Röcker, C.; Kunz, G.; Bruneel, D.; Delaigue, M.; Graf, T.; Ahmed, M.A. High-quality high-throughput silicon laser milling using a 1 kW sub-picosecond laser. Opt. Lett. 2021, 46, 384–387. [Google Scholar] [CrossRef] [PubMed]
  15. Holder, D.; Weber, R.; Graf, T.; Onuseit, V.; Brinkmeier, D.; Förster, D.J.; Feuer, A. Analytical model for the depth progress of percussion drilling with ultrashort laser pulses. Appl. Phys. A 2021, 127, 1–8. [Google Scholar] [CrossRef]
  16. Döring, S.; Richter, S.; Tünnermann, A.; Nolte, S. Evolution of hole depth and shape in ultrashort pulse deep drilling in silicon. Appl. Phys. A 2011, 105, 69–74. [Google Scholar] [CrossRef]
  17. Webster, P.J.L.; Yu, J.X.Z.; Leung, B.Y.C.; Anderson, M.D.; Yang, V.X.D.; Fraser, J.M. In situ 24 kHz coherent imaging of morphology change in laser percussion drilling. Opt. Lett. 2010, 35, 646–648. [Google Scholar] [CrossRef] [PubMed]
  18. Holder, D.; Leis, A.; Buser, M.; Weber, R.; Graf, T. High-quality net shape geometries from additively manufactured parts using closed-loop controlled ablation with ultrashort laser pulses. Adv. Opt. Technol. 2020, 9, 101–110. [Google Scholar] [CrossRef]
  19. Holder, D.; Buser, M.; Boley, S.; Weber, R.; Graf, T. Image processing based detection of the fibre orientation during depth-controlled laser ablation of CFRP monitored by optical coherence tomography. Mater. Des. 2021, 203, 109567. [Google Scholar] [CrossRef]
  20. Cangueiro, L.; Audouard, E.; Martin, P.-E.; Mottay, E.; Ramos-de-Campos, J.A.; Kupisiewicz, A.; Bruneel, D. Model for Ultrafast Laser Micromachining; Klotzbach, U., Washio, K., Kling, R., Eds.; Laser-based Micro- and Nanoprocessing XII; SPIE: Bellingham, DC, USA, 2018; p. 38. [Google Scholar]
  21. Michalowski, A. Untersuchungen zur Mikrobearbeitung von Stahl mit Ultrakurzen Laserpulsen; Herbert Utz Verlag: München, Germany, 2014. [Google Scholar]
  22. Mannion, P.; Magee, J.; Coyne, E.; O’Connor, G.; Glynn, T. The effect of damage accumulation behaviour on ablation thresholds and damage morphology in ultrafast laser micro-machining of common metals in air. Appl. Surf. Sci. 2004, 233, 275–287. [Google Scholar] [CrossRef]
  23. Neuenschwander, B.; Jaeggi, B.; Schmid, M.; Dommann, A.; Neels, A.; Bandi, T.; Hennig, G. Factors Controlling the Incubation in the Application of Ps Laser Pulses on Copper and Iron Surfaces; Xu, X., Hennig, G., Nakata, Y., Roth, S.W., Eds.; Laser Applications in Microelectronic and Optoelectronic Manufacturing (LAMOM) XVIII; SPIE: Bellingham, DC, USA, 2013; p. 86070D. [Google Scholar]
  24. Jee, Y.; Becker, M.F.; Walser, R.M. Laser-induced damage on single-crystal metal surfaces. J. Opt. Soc. Am. B 1988, 5, 648–659. [Google Scholar] [CrossRef]
  25. Hügel, H.; Graf, T. Laser in der Fertigung: Strahlquellen, Systeme, Fertigungsverfahren, 3rd ed.; Vieweg+Teubner Verlag: Wiesbaden, Germany, 2014. [Google Scholar]
  26. Nolte, S.; Momma, C.; Jacobs, H.; Tünnermann, A.; Chichkov, B.N.; Wellegehausen, B.; Welling, H. Ablation of metals by ultrashort laser pulses. J. Opt. Soc. Am. B 1997, 14, 2716–2722. [Google Scholar] [CrossRef]
  27. Kononenko, T.V.; Konov, V.I.; Garnov, S.V.; Klimentov, S.M.; Dausinger, F. Dynamics of Deep Short Pulse Laser Drilling: Ablative Stages and Light Propagation. Laser Phys. 2001, 11, 343–351. [Google Scholar]
  28. Lide, D.R. CRC Handbook of Chemistry and Physics; CRC Press/Taylor and Francis: Boca Ranton, FL, USA, 2010. [Google Scholar]
  29. Habashi, F. Titanium, Physical and Chemical Properties. In Encyclopedia of Metalloproteins; Kretsinger, R.H., Uversky, V.N., Permyakov, E.A., Eds.; Springer: New York, NY, USA, 2013; pp. 2251–2252. [Google Scholar]
  30. Palm, K.J.; Murray, J.B.; Narayan, T.C.; Munday, J.N. Dynamic Optical Properties of Metal Hydrides. ACS Photonics 2018, 5, 4677–4686. [Google Scholar] [CrossRef] [Green Version]
  31. Maharjan, N.; Zhou, W.; Zhou, Y.; Guan, Y. Ablation morphology and ablation threshold of Ti-6Al-4V alloy during femtosecond laser processing. Appl. Phys. A 2018, 124, 519. [Google Scholar] [CrossRef]
  32. Zhigilei, L.V.; Lin, Z.; Ivanov, D.S. Atomistic Modeling of Short Pulse Laser Ablation of Metals: Connections between Melting, Spallation, and Phase Explosion. J. Phys. Chem. C 2009, 113, 11892–11906. [Google Scholar] [CrossRef] [Green Version]
Figure 1. V-shaped groove produced by a pulsed laser beam which is scanned along the x-axis. The Gaussian distribution of the fluence of the individual laser pulses is shown by the red curve. The width of the groove is denoted by dG = 2 rabl, which corresponds to two times the ablation radius rabl. The incrementally increased depth of the groove is denoted by zG,n, where n is the number of applied scans and zS,n = zG,nzG,n − 1 is the incremental increase in the depth produced by the nth scan along the groove. The cross section of the volume ablated during the nth scan is highlighted by the red hatched cross section.
Figure 1. V-shaped groove produced by a pulsed laser beam which is scanned along the x-axis. The Gaussian distribution of the fluence of the individual laser pulses is shown by the red curve. The width of the groove is denoted by dG = 2 rabl, which corresponds to two times the ablation radius rabl. The incrementally increased depth of the groove is denoted by zG,n, where n is the number of applied scans and zS,n = zG,nzG,n − 1 is the incremental increase in the depth produced by the nth scan along the groove. The cross section of the volume ablated during the nth scan is highlighted by the red hatched cross section.
Micromachines 13 00870 g001
Figure 2. Absorbed fluence distributions ϕtip,n,j(x) along the x axis at y = 0 of the incident pulses (a) from j = −3 to j = 0 and (b) from j = 0 to j = 3. The coloured small arrows indicate the absorbed fluence at the location x0. The intersection of the fluence distributions ϕtip,n,j(x) with the ablation threshold ϕth determines the maximum number of pulses jabl,n contributing to ablation in this direction along the x axis.
Figure 2. Absorbed fluence distributions ϕtip,n,j(x) along the x axis at y = 0 of the incident pulses (a) from j = −3 to j = 0 and (b) from j = 0 to j = 3. The coloured small arrows indicate the absorbed fluence at the location x0. The intersection of the fluence distributions ϕtip,n,j(x) with the ablation threshold ϕth determines the maximum number of pulses jabl,n contributing to ablation in this direction along the x axis.
Micromachines 13 00870 g002
Figure 3. Cross sections of grooves micromachined in Ti6Al4V with the parameter set P1. The depth and width of each groove are indicated by a yellow double arrow and a green double arrow, respectively.
Figure 3. Cross sections of grooves micromachined in Ti6Al4V with the parameter set P1. The depth and width of each groove are indicated by a yellow double arrow and a green double arrow, respectively.
Micromachines 13 00870 g003
Figure 4. Calculated groove depth (dotted lines, “Model”) and measured groove depth (data points, “Measured”) as a function of the number of scans for grooves micromachined in Ti6Al4V using the different parameter sets as given in Table 1.
Figure 4. Calculated groove depth (dotted lines, “Model”) and measured groove depth (data points, “Measured”) as a function of the number of scans for grooves micromachined in Ti6Al4V using the different parameter sets as given in Table 1.
Micromachines 13 00870 g004
Figure 5. Cross sections of grooves micromachined in Ti6Al4V with (a) P1, n = 1500, (b) P2, n = 10,000, (c) P3, n = 8000, (d) P4, n = 8000, and (e) P5, n = 5000. An isosceles triangle with the dimensions of the calculated depth and width of the corresponding groove using the model presented in Section 2 is inserted for each parameter set in the respective colour.
Figure 5. Cross sections of grooves micromachined in Ti6Al4V with (a) P1, n = 1500, (b) P2, n = 10,000, (c) P3, n = 8000, (d) P4, n = 8000, and (e) P5, n = 5000. An isosceles triangle with the dimensions of the calculated depth and width of the corresponding groove using the model presented in Section 2 is inserted for each parameter set in the respective colour.
Micromachines 13 00870 g005
Table 1. Sets of parameters as used for micromachining of grooves with different depths and widths.
Table 1. Sets of parameters as used for micromachining of grooves with different depths and widths.
Pav in WEP in µJ ϕ0 in J/cm²frep in kHzvx in m/sδx in µmΩxNumber of Scans n
P19.051813.81501.22478%300…10,000
P23.45691.45501.22478%300…10,000
P36.90691.451002.42478%600…20,000
P43.45691.45502.44856%600…20,000
P53.45691.45500.61289%150…5000
Table 2. Material properties of titanium, as published in [28,29] used for the calculation of the volume-specific enthalpy hV for heating and vaporization.
Table 2. Material properties of titanium, as published in [28,29] used for the calculation of the volume-specific enthalpy hV for heating and vaporization.
Material ParameterValue
Density 4506 kg m 3 [28]
Heat capacity for solid titanium 523 J kg K [28]
Melting temperature1668 °C [28]
Latent heat of melting 440 kJ kg [29]
Vaporization temperature3287 °C [28]
Latent heat of vaporization 8305 kJ kg [29]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Holder, D.; Weber, R.; Graf, T. Analytical Model for the Depth Progress during Laser Micromachining of V-Shaped Grooves. Micromachines 2022, 13, 870. https://doi.org/10.3390/mi13060870

AMA Style

Holder D, Weber R, Graf T. Analytical Model for the Depth Progress during Laser Micromachining of V-Shaped Grooves. Micromachines. 2022; 13(6):870. https://doi.org/10.3390/mi13060870

Chicago/Turabian Style

Holder, Daniel, Rudolf Weber, and Thomas Graf. 2022. "Analytical Model for the Depth Progress during Laser Micromachining of V-Shaped Grooves" Micromachines 13, no. 6: 870. https://doi.org/10.3390/mi13060870

APA Style

Holder, D., Weber, R., & Graf, T. (2022). Analytical Model for the Depth Progress during Laser Micromachining of V-Shaped Grooves. Micromachines, 13(6), 870. https://doi.org/10.3390/mi13060870

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop