Next Article in Journal
Habitat Modelling on the Potential Impacts of Shipping Noise on Fin Whales (Balaenoptera physalus) in Offshore Irish Waters off the Porcupine Ridge
Previous Article in Journal
Integral Sliding Mode Based Finite-Time Tracking Control for Underactuated Surface Vessels with External Disturbances
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Underwater Spectral Imaging System Based on Liquid Crystal Tunable Filter

1
Ocean Engineering and Technology, Ocean College, Zhejiang University, Zheda Road 1, Zhoushan 316021, China
2
Blackett Laboratory, Department of Physics, Imperial College London, South Kensington Campus, London SW7 2AZ, UK
3
School of Electronics and Computer Engineering, Peking University, Shenzhen 518055, China
*
Author to whom correspondence should be addressed.
J. Mar. Sci. Eng. 2021, 9(11), 1206; https://doi.org/10.3390/jmse9111206
Submission received: 24 September 2021 / Revised: 27 October 2021 / Accepted: 29 October 2021 / Published: 1 November 2021
(This article belongs to the Section Physical Oceanography)

Abstract

:
In the past decade, underwater spectral imaging (USI) has shown great potential in underwater exploration for its high spectral and spatial resolution. This proposal presents a stare-type USI system combined with the liquid crystal tunable filter (LCTF) spectral splitting device. Considering the working features of LCTF and the theoretical model of USI, the core structure containing “imaging lens-LCTF-imaging sensor” is designed and developed. The system is compact, and the optical geometry is constructed minimally. The spectral calibration test analysis proved that the spectral response range of the system covers a full band of 400 nm to 700 nm with the highest spectral resolution between 6.7 nm and 18.5 nm. The experiments show that the system can quickly collect high-quality spectral image data by switching between different spectral bands arbitrarily. The designed prototype provides a feasible and reliable spectral imaging solution for in situ underwater targets observation with high spectrum collecting efficiency.

1. Introduction

The fundamental of spectral imaging is to fuse multi-dimensional spatial geometric information of the image with spectral information radiating from the target surface to obtain spectral image cube data [1]. It is widely used for military, remote sensing detection [2], marine observation purposes [3], etc. In the 21st century, marine observation became an important debate and research topic [4,5], which presently relies on different techniques, such as satellite remote sensing based on spectral imaging, and underwater target detection based on acoustics and optical imaging. Although the methods mentioned above are well developed and can carry out continuous observation on a large scale, there are difficulties associated with underwater observation. It is highly vulnerable to various interferences, which causes lower detection accuracy. Underwater monitoring based on acoustic detection and optical imaging have a relatively low resolution in detecting the targeted object. Similarly, observation based on remote sensing is limited to surface or shallow water observation due to higher detection distance and interference caused by the air–water interface.
To overcome the hybrid effect of the air–water interface, the idea of USI is introduced to achieve relatively higher target detection accuracy in underwater monitoring. The ability to collect spontaneous and clear insight into diverse targets’ image and spectral information gives USI a distinct advantage in underwater detection. In the marine observation system, it can be utilized to detect corals’ health status, which can efficiently maintain the coral reefs and other organisms in the surrounding habitat [6]. It can also monitor the health and growth status of aquatic products in aquaculture, which can highly improve the quality of production. Being an advanced addition to underwater imaging, USI is also one of the most powerful technologies for surveying marine oil and gas, archeology [7], benthic habitat mapping, and seabed minerals exploration.
Spectral imaging is still a new and emerging technology for underwater imaging; however, researchers have designed some equipment for underwater surveillance systems. Since 2009, the Norwegian University of Science and Technology (NTNU), in cooperation with the Ecotone company, has started to study the applications of push-broom underwater hyperspectral imaging (UHI) based on prism splitting methods for underwater target detection [8]. Several versions of UHI with different specifications have been designed and developed, which have been installed to perform continuous underwater monitoring. In 2012, NTNU developed a fourth-generation digital UHI [9] and deployed this on a small, remotely operated vehicle to perform submarine hyperspectral imaging of cold-water corals [10]. The developed system has also been used to detect submarine pipelines and sunken ships [11]. Since then, UHI has been installed to carry out several underwater operations for algae [12], corals [13], and different seabed minerals exploration [14,15].
In 2016, Zhejiang University China developed a multispectral imaging system based on a narrowband rotating filter to switch between different spectral channels [16]. The rotatory filter system consists of 30 filters divided into two rotating wheels to reduce the system’s volume. The team performed several underwater spectral imaging and system calibration operations [17] and later researched spectral image reconstruction algorithm [18,19].
A German institute, Max Plank Institute of Marine Microbiology, in 2017 developed a handheld push-broom UHI system called the HyperDriver to monitor the shallow marine ecosystem [20]. The system was equipped with a spectral imager, color imager, auxiliary lighting, and sensors to simultaneously capture hyperspectral and color images, bottom altitude, depth, irradiance, and chemical parameters. The UHI can provide hyperspectral information with centimeter spatial resolution.
In 2018, researchers from China collaborated with Helmholtz Institute of Oceanography in Germany to develop an underwater multispectral imaging system based on a narrowband light-emitting diode (LED) light source [21]. The method utilized eight narrowband led light sources with adjustable light intensity to achieve spectral splitting, using a black and white industrial camera, imaging lens, and single-chip microcomputer to control LED to switch flashing in turns and to capture images synchronously.
Recently, in 2021, another UHI based on push-broom scan imaging mode was designed and developed by the Ocean University of China [22]. In the model, prism-grating-prism structure is adopted as the spectral unit to reduce spectral line bending. After calibration and underwater experimentation, the compact structured UHI system resulted in high image quality and spectral resolution. The system achieved high stability and good detection, realizing in large-scale target detection.
Several spectral imaging techniques are being adopted to perform a wide range of underwater detection, including starring type, snapshot, and push-broom imaging methods [23]. To maximize the performance and minimize the mechanical complexity of spectral imaging for underwater application, this paper presents the design and development of a stare-type USI system based on LCTF. The system is designed in a compact and optically simplified manner. The critical parameters of spectral imaging are calibrated accordingly for better performance in the underwater environment. The developed prototype is tested to meet the needs of high-quality spectral imaging with higher spectral resolution and high signal-to-noise ratio (SNR) to overcome the attenuation in image quality caused by the water body.
The rest of the paper is arranged as follows: Section 2 describes the design and development of the USI system, explaining its core components and specifications. Prototype testing and calibration are included in Section 3. The performance of the designed system in underwater conditions is described in Section 4. Finally, in Section 5, the proposed work is experimentally concluded, and future research directions and discussion are noted.

2. USI System Design and Development

Figure 1 presents the compact structure of the designed prototype USI system. The design of the stare-type USI system adopts the core optical formation, composed of an imaging lens-LCTF-imaging sensor. To adjust precise focusing, the large-diameter lens is controlled by an electric stepper motor. The transmission wavelength of the LCTF is controlled to achieve narrowband scanning in the visible spectral range. A scientific-grade charged coupled device (CCD) camera is used as an imaging sensor in the system to realize the imaging sensitivity of the underwater environment. The detailed specification of parameters in the optical module is presented in Table 1.
In the control module, the microcomputer (NUC6i5SYK, Intel, Santa Clara, CA, USA) is responsible for sending control instructions, data transmission, storage, and processing. The camera and LCTF are connected with the microcomputer through USB protocol. Spectral imaging parameters and LCTF central wavelength switching can be set directly through system software. The microcomputer sends a switching command to the stepper motor drive circuit through the remote I/O module (IPAM 1808, GuanHangda, China) to accurately drive the stepper motor rotation inside the lens.
To achieve high accuracy of the USI model, the functional characteristics of each component and corresponding strategies are analyzed, and a control algorithm and software are designed on Visual Studio 2015. The algorithm controls various system functions such as; CCD camera function, adjustment of the lens by controlling stepper motor drive, and LCTF tuning for scanning step size, range, and interval. The control algorithm of the system also holds several sub-interfaces, such as “image acquisition”, “LED control”, and “multi-spectrum image data analysis”. Microsoft Foundation Classes (MFC) is utilized for software interface, and OpenCV is integrated for image visualization and processing operations. Modules and sub-functions of the control system are displayed in Appendix A Figure A1. Lastly, all the modules are installed in a waterproof mechanical encapsulation for underwater operations; the structure parameters are described in Table 2.

3. Spectral Testing and Calibration

After the optical system installation and the mechanical design pressure test analysis, the USI system prototype is sealed to maintain waterproof design requirements. Later, the imaging parameters of the prototype, such as spectral resolution, spectral response sensitivity, and underwater detection sensitivity limit, are tested and calibrated using a standard monochromator and spectrometer.

3.1. Spectral Resolution

Based on the definitions of spectral resolution, the designed prototype is calibrated for full-width at half-maximum (FWHM) of the response spectrum of the system on different wavelengths, and the least distinguishable central wavelength interval between two narrowband monochromatic beams. The experimental setup is shown in Figure 2; after execution, the relative spectral response and FWHM are calculated, as shown in Figure 3 and Figure 4. The FWHM of the response spectrum of the system is 6.7 nm to 18.5 nm. The highest spectral resolution can reach 10 nm, and the modulation offset of central wavelength is less than ±1.45 nm.
Further testing, as shown in Figure 5, was conducted using a mercury argon lamp to verify the spectral resolution of the designed prototype. The lamp emits a high-intensity spectrum at a specific wavelength ranging from 400 nm to 700 nm. The relative spectral intensity distribution curve justifies that the system can sufficiently distinguish the highly narrowband characteristic peaks emitted by the lamp.

3.2. Spectral Radiometric Calibration

The pixel response of the actual signal is directly proportional to the exposure time and the spectral radiance of the corresponding target. Therefore, the one-to-one correspondence (calibration relation) between the spectral response measured by the USI system and the known spectral radiance can be established at a certain distance. In this section, the calibration relationship between system response and absolute radiance is measured in the air to calculate the total spectral radiance corresponding to unit pixel response.
Figure 6 explains the experimental plan and standard instruments, including halogen lamp (F970), regulated power supply, and white board surface (made of barium sulfate or polytetrafluoroethylene, regarded as an ideal Lambert diffuse surface). The filament center of the lamp and the center of the whiteboard are 50 cm apart on the same optical axis. For system calibration, darkroom imaging at full-band from 400 nm to 700 nm is performed at the step of 1 nm. The calibration performance of the system at different operating wavelengths and unit exposure time (1 ms) is shown in Figure 7. Compared with the standard spectral radiance, the USI system yielded a residual sum of squares of 2.275 × 10−5 for all bands, with an average relative error of 2.36%.

3.3. Spectral Detection Sensitivity

A low illumination environment easily restricts the practical application of the USI system due to the influence of non-uniform spectral absorption and scattering caused by water. Therefore, it is necessary to measure the detection threshold of the lowest incident spectral radiance in different working bands, which is called spectral detection sensitivity (SDS) in the paper. SDS shows the ability of the system to detect the weakest signal during imaging under zero supplementary illumination.
The designed prototype is calibrated at the systems’ working temperature of 37 °C and electron gain of 1. One hundred darkroom images are captured during experiments at the maximum exposure time. The average standard deviation is calculated as 133.7, which is applied as the amplitude of random noise. Theoretically, when the SNR (that is, effective signal to random noise) is 1, the response of effective signal at maximum exposure time is 133.7, and normalized response at unit exposure is 0.002674. According to unit exposure, time and absolute spectral radiance corresponding to the unit pixel response value, the SDS limit of the system at 37 °C for 400 nm to 700 nm is calculated as shown in Figure 8.

4. Underwater Testing

To explore the potential of designed USI system for practical applications, the prototype is tested for its performance in an underwater environment after the calibration of key spectral imaging parameters. Figure A2 and Figure A3 present the USI setup combined with a supplementary light source used for a series of underwater trials. The detection range of the USI system is explored in pool testing under simultaneous illumination of six high-power (150 W) LED light sources. As in Figure 9, several spectral image data of a whiteboard (50 cm × 40 cm, with 80% spectral reflectance) at an 8 m distance are collected under varying wavelengths.
As shown in Figure 10, the brightness distribution of the whiteboard surface at different imaging distances is relatively uniform. The standard deviation of brightness fluctuation to the average brightness of the whiteboard spectral image of 410 nm to 700 nm is 0.017 to 0.070. The brightness fluctuation of the whiteboard area in the spectral image of the 400 nm band is relatively large, which is mainly due to the lower system response and low SNR of the working wavelength. The interference of stray light in the water body can be highly observed. It is also noticed that, at a farther imaging distance, the ratio of brightness of target whiteboard and background is closer to 1 near 400 nm and 700 nm. It is concluded that the accuracy of spectral image data is highly disrupted with weaker target signals due to higher interference caused by water backscattering.
Furthermore, due to the non-uniform attenuation of spectral energy by water, the spectral energy distribution received by the USI system is distorted. Therefore, the associated problem requires the necessary compensation of spectral energy attenuation for spectral image data collected at different underwater imaging distances. The attenuation degree of underwater spectral energy is related to the imaging distance, which causes distortion in the original spectral features. To minimize the influence of the water body on spectral characteristics of the same target, the spectral response of the target at different imaging ranges is normalized to the spectral response at the same distance.
Additional testing is conducted on a color plate as the target, and a series of spectral images are collected at different imaging distances, as shown in Figure 11. Following the previous results, the SNR and spectral information reliability of spectral images at 400 nm and 700 nm, the data processing and analysis of 410 nm to 690 nm for color plate is carried out, as shown in Figure 12.
As shown in Figure 13, through the water attenuation compensation, the results of color plate spectral images in the 550 nm band and 650 nm band at different imaging distances are uniformly compensated to 7 m. From the relative compensation errors of varying color blocks, it can also be seen that the accuracy of compensation is high, which is very close to the actual spectral response under the target compensation distance. Therefore, through the water attenuation compensation algorithm, the spectral response at different lengths can be accurately corrected to the target value at the same distance so that the spectral characteristics at different distances are consistent and provide a more realistic spectral image.

5. Conclusions

Based on the in-depth investigation of the development status of spectral imaging technology and research of USI theory, in this paper, a stare-type spectral imaging system was designed for underwater applications. An LCTF was used as a principal spectral splitting device in the system. A series of calibration tests was performed in order to analyze the accuracy of the data collected by the system. The proposed USI model highly simplifies the mechanical complexity and enhances the spectral imaging performance. The working wavelength of the system was maintained in order to be easily modulated and switched along with the full-band spectral range of 400 nm to 700 nm with a spectral resolution better than 10 nm. The FWHM of the response spectrum at different central wavelengths was 6.7 nm to 18.5 nm.
Following the excellent performance of the prototype USI system, it can be concluded that the proposed USI system has the advantage of compact mechanical structure and simplified optical geometry, high efficiency, high SNR, and enhanced resolution. Compared with push-broom spectral imaging models, it has the most straightforward optical geometric correction. To sum up, the designed system can be considered highly reliable for in situ non-contact monitoring of seabed, coral reef observation, etc. Future studies on the system will include modeling and correcting noises caused by water bodies, which will improve spectral imaging quality. The system will be employed for detailed in situ monitoring of different underwater targets.

Author Contributions

Conceptualization, H.S., S.R.M. and C.W.; methodology and designing, S.R.M. and C.W.; software, C.W. and Z.L.; validation, H.G. and H.H.; experimental analysis and investigation, H.S., S.R.M., C.W., Z.L. and A.A.; data curation, H.S., S.R.M., H.G., A.A. and H.H.; writing—original draft preparation, S.R.M.; writing—review and editing, H.S., S.R.M., H.G. and A.A.; visualization, H.S., S.R.M., C.W., H.G. and H.H.; supervision, H.S. and H.H.; funding acquisition, H.H. All authors have read and agreed to the published version of the manuscript.

Funding

This study was financially supported by the Key Research and Development Plan of Zhejiang Province, China (Grant number: 2019C02050, 2020C03012, 2021C03181), and the National Science Foundation of China (Grant number: 31801619).

Institutional Review Board Statement

Not applicable for this study.

Informed Consent Statement

Not applicable for this study.

Data Availability Statement

Data underlying the results presented in this paper are not publicly available at this time due to being part of ongoing work, but may be obtained from the authors later upon reasonable request.

Acknowledgments

The authors would like to present gratitude to the team of “Smart Optics Lab”, Ocean College, Zhejiang University for their contribution during the development and especially in carrying out underwater experiments.

Conflicts of Interest

The authors declare no conflict of interest.

Appendix A

Figure A1. Control algorithm and software structure of USI system and supplementary light source.
Figure A1. Control algorithm and software structure of USI system and supplementary light source.
Jmse 09 01206 g0a1
Figure A2. The optical module’s brief schematics explain the working principle of the designed USI prototype to obtain spectral image data cube in underwater operations.
Figure A2. The optical module’s brief schematics explain the working principle of the designed USI prototype to obtain spectral image data cube in underwater operations.
Jmse 09 01206 g0a2
Figure A3. Complete composition of USI system and high-power LEDs light source for underwater trials.
Figure A3. Complete composition of USI system and high-power LEDs light source for underwater trials.
Jmse 09 01206 g0a3

References

  1. Polerecky, L.; Bissett, A.; Al-Najjar, M.; Faerber, P.; Osmers, H.; Suci, P.A.; Stoodley, P.; de Beer, D. Modular spectral imaging system for discrimination of pigments in cells and microbial communities. Appl. Env. Microbiol. 2009, 75, 758–771. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Carrino, T.A.; Crósta, A.P.; Toledo, C.L.B.; Silva, A.M. Hyperspectral remote sensing applied to mineral exploration in Southern Peru: A multiple data integration approach in the chapi chiara gold prospect. Int. J. Appl. Earth Obs. 2018, 64, 287–300. [Google Scholar] [CrossRef]
  3. Pu, H.; Liu, D.; Qu, J.H.; Sun, D.W. Applications of imaging spectrometry in inland water quality monitoring—A review of recent developments. Water Air Soil Pollut. 2017, 228, 131. [Google Scholar] [CrossRef]
  4. Song, H.; Mehdi, S.R.; Huang, H.; Shahani, K.; Zhang, Y.; Junaidullah, K.R.; Khan, M.A. Classification of freshwater zooplankton by pre-trained convolutional neural network in underwater microscopy. Int. J. Adv. Comput. Sci. Appl. 2020, 11, 252–258. [Google Scholar]
  5. Shahani, K.; Song, H.; Mehdi, S.R.; Sharma, A.; Tunio, G.; Qureshi, J.; Kalhoro, N.; Khaskheli, N. Design and testing of an underwater microscope with variable objective lens for the study of benthic communities. J. Mar. Sci. Appl. 2021, 20, 170–178. [Google Scholar] [CrossRef]
  6. Song, H.; Mehdi, S.R.; Zhang, Y.; Shentu, Y.; Wan, Q.; Wang, W.; Raza, K.; Huang, H. Development of coral investigation system based on semantic segmentation of single-channel images. Sensors 2021, 21, 1848. [Google Scholar] [CrossRef]
  7. Ødegård, Ø.; Mogstad, A.A.; Johnsen, G.; Sørensen, A.J.; Ludvigsen, M. Underwater hyperspectral imaging: A new tool for marine archaeology. Appl. Opt. 2018, 57, 3214–3223. [Google Scholar] [CrossRef] [Green Version]
  8. Johnsen, G. Underwater Hyperspectral Imaging. U.S. Patent 8,502,974, 6 August 2013. [Google Scholar]
  9. Johnsen, G.; Ludvigsen, M.; Sørensen, A.; Aas, L.M.S. The use of underwater hyperspectral imaging deployed on remotely operated vehicles-methods and applications. IFAC-PapersOnLine 2016, 49, 476–481. [Google Scholar] [CrossRef]
  10. Ludvigsen, M.; Johnsen, G.; Sørensen, A.J.; Lågstad, P.A.; Ødegård, Ø. Scientific operations combining ROV and AUV in the Trondheim Fjord. Mar. Technol. Soc. J. 2014, 48, 59–71. [Google Scholar] [CrossRef]
  11. Tegdan, J.; Ekehaug, S.; Hansen, I.M.; Aas, L.M.S.; Steen, K.J.; Pettersen, R.; Beuchel, F.; Camus, L. Underwater hyperspectral imaging for environmental mapping and monitoring of seabed habitats. In Proceedings of the IEEE/MTS OCEANS’15 (IEEE, 2015), Genova, Italy, 18–21 May 2015; pp. 1–6. [Google Scholar]
  12. Mogstad, A.A.; Johnsen, G. Spectral characteristics of coralline algae: A multi-instrumental approach, with emphasis on underwater hyperspectral imaging. Appl. Opt. 2017, 56, 9957–9975. [Google Scholar] [CrossRef]
  13. Letnes, P.A.; Hansen, I.M.; Aas, L.M.; Eide, I.; Pettersen, R.; Tassara, L.; Receveur, J.; le Floch, S.; Guyomarch, J.; Camus, L.; et al. Underwater hyperspectral classification of deep sea corals exposed to a toxic compound. bioRxiv 2017, 150060. [Google Scholar] [CrossRef] [Green Version]
  14. Dumke, I.; Nornes, S.M.; Purser, A.; Marcon, Y.; Ludvigsen, M.; Ellefmo, S.L.; Johnsen, G.; Søreide, F. First hyperspectral imaging survey of the deep seafloor: High-resolution mapping of manganese nodules. Remote Sens. Environ. 2018, 209, 19–30. [Google Scholar] [CrossRef]
  15. Dumke, I.; Purser, A.; Marcon, Y.; Nornes, S.M.; Johnsen, G.; Ludvigsen, M.; Søreide, F. Underwater hyperspectral imaging as an in situ taxonomic tool for deep-sea megafauna. Sci. Rep. 2018, 8, 1–11. [Google Scholar]
  16. Guo, Y.; Song, H.; Liu, H.; Wei, H.; Yang, P.; Zhan, S.; Wang, H.; Huang, H.; Liao, N.; Mu, Q.; et al. Model-based restoration of underwater spectral images captured with narrowband filters. Opt. Express 2016, 24, 13101–13120. [Google Scholar] [CrossRef] [PubMed]
  17. Wu, C.; Shentu, Y.; Chaofan, C.; Guo, Y.; Zhang, Y.; Wei, H.; Yang, P.; Huang, H.; Song, H. Development of an underwater multispectral imaging system based on narrowband color filters. In Proceedings of the IEEE/MTS OCEANS’18 (IEEE, 2018), Charleston, SC, USA, 22–25 October 2018; pp. 1–6. [Google Scholar]
  18. Yang, P.; Guo, Y.; Wei, H.; Song, D.; Song, H.; Zhang, Y.; Shentu, Y.; Liu, H.; Huang, H.; Zhang, Z.; et al. Method for spectral restoration of underwater images: Theory and application. Infrared Laser Eng. 2017, 46, 1–8. [Google Scholar]
  19. Wei, H.; Guo, Y.; Yang, P.; Song, H.; Liu, H.; Zhang, Y. Underwater multispectral imaging: The influences of color filters on the estimation of underwater light attenuation. In Proceedings of the IEEE/MTS OCEANS’17 (IEEE, 2018), Aberdeen, UK, 19–22 June 2017; pp. 1–4. [Google Scholar]
  20. Chennu, A.; Färber, P.; De’ath, G.; de Beer, D.; Fabricius, K.E. A diver-operated hyperspectral imaging and topographic surveying system for automated mapping of benthic habitats. Sci. Rep. 2017, 7, 7122. [Google Scholar] [CrossRef] [PubMed]
  21. Liu, H.; Sticklus, J.; Köser, K.; Hoving, H.-J.T.; Song, H.; Chen, Y.; Greinert, J.; Schoening, T. TuLUMIS-a tunable LED-based underwater multispectral imaging system. Opt. Express 2018, 26, 7811–7828. [Google Scholar] [CrossRef] [PubMed]
  22. Xue, Q.; Tian, Z.; Yang, B.; Liang, J.; Li, C.; Wang, F.; Li, Q. Underwater hyperspectral imaging system using a prism–grating–prism structure. Appl. Opt. 2021, 60, 894–900. [Google Scholar] [CrossRef] [PubMed]
  23. Liu, B.; Liu, Z.; Men, S.; Li, Y.; Ding, Z.; He, J.; Zhao, Z. Underwater hyperspectral imaging technology and its applications for detecting and mapping the seafloor: A review. Sensors 2020, 20, 4962. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Encapsulated structure of the designed USI system. The hardware includes optical (lens, LCTF, and imaging sensor) and control (microcomputer, motor drive circuit, remote I/O circuitry, and voltage convertor) modules installed in a waterproof mechanical structure.
Figure 1. Encapsulated structure of the designed USI system. The hardware includes optical (lens, LCTF, and imaging sensor) and control (microcomputer, motor drive circuit, remote I/O circuitry, and voltage convertor) modules installed in a waterproof mechanical structure.
Jmse 09 01206 g001
Figure 2. Setup and illustration for spectral resolution calibration of the designed USI system. A xenon light source (7ILX150C, SaiFan photoelectricity, China), a double-grating monochromator (7ISU151, SaiFan photoelectricity, China), a spectral radiometer (PR715, JADAK, North Syracuse, NY, USA), and a high-resolution fiber spectrometer (HR400, Ocean Insight, Orlando, FL, USA) are used in the experiment.
Figure 2. Setup and illustration for spectral resolution calibration of the designed USI system. A xenon light source (7ILX150C, SaiFan photoelectricity, China), a double-grating monochromator (7ISU151, SaiFan photoelectricity, China), a spectral radiometer (PR715, JADAK, North Syracuse, NY, USA), and a high-resolution fiber spectrometer (HR400, Ocean Insight, Orlando, FL, USA) are used in the experiment.
Jmse 09 01206 g002
Figure 3. The response spectrum of the designed USI system relative to corresponding wavelengths. The graph represents the system’s capability to distinguish between a full band of 400 nm to 700 nm at a maximum resolution of 10 nm.
Figure 3. The response spectrum of the designed USI system relative to corresponding wavelengths. The graph represents the system’s capability to distinguish between a full band of 400 nm to 700 nm at a maximum resolution of 10 nm.
Jmse 09 01206 g003
Figure 4. Modulation accuracy of FWHM and central wavelength of response spectrum of USI system.
Figure 4. Modulation accuracy of FWHM and central wavelength of response spectrum of USI system.
Jmse 09 01206 g004
Figure 5. The relative spectral intensity distribution of a mercury argon lamp measured by USI system. The spectral intensity curve shows that the designed system can differentiate between narrowband peaks. However, the system response relies on low spectral intensity and low signal-to-noise ratio (SNR), which results in uncertainty in distinguishing the peaks at a lower wavelength.
Figure 5. The relative spectral intensity distribution of a mercury argon lamp measured by USI system. The spectral intensity curve shows that the designed system can differentiate between narrowband peaks. However, the system response relies on low spectral intensity and low signal-to-noise ratio (SNR), which results in uncertainty in distinguishing the peaks at a lower wavelength.
Jmse 09 01206 g005
Figure 6. Schematics of the experimental setup for spectral radiometric calibration of the designed USI system.
Figure 6. Schematics of the experimental setup for spectral radiometric calibration of the designed USI system.
Jmse 09 01206 g006
Figure 7. Calibration test of USI system in the air. Unit pixel response corresponding to absolute spectral radiance (left). Calibration relationship test results (right).
Figure 7. Calibration test of USI system in the air. Unit pixel response corresponding to absolute spectral radiance (left). Calibration relationship test results (right).
Jmse 09 01206 g007
Figure 8. SDS limits of different working wavelengths of the USI system.
Figure 8. SDS limits of different working wavelengths of the USI system.
Jmse 09 01206 g008
Figure 9. Partial spectral image of target whiteboard at 8 m distance, illuminated by underwater LED light source.
Figure 9. Partial spectral image of target whiteboard at 8 m distance, illuminated by underwater LED light source.
Jmse 09 01206 g009
Figure 10. Spectral characteristics of remote target whiteboard illuminated by underwater LED light source.
Figure 10. Spectral characteristics of remote target whiteboard illuminated by underwater LED light source.
Jmse 09 01206 g010
Figure 11. Observing color plate by USI system under supplementary illumination during pool testing.
Figure 11. Observing color plate by USI system under supplementary illumination during pool testing.
Jmse 09 01206 g011
Figure 12. Single-channel spectral image of partial band color plate collected in pool test.
Figure 12. Single-channel spectral image of partial band color plate collected in pool test.
Jmse 09 01206 g012
Figure 13. Example of the spectral images at different distances uniformly compensated to 7 m using water attenuation compensation. (a Relative error of varying color blocks).
Figure 13. Example of the spectral images at different distances uniformly compensated to 7 m using water attenuation compensation. (a Relative error of varying color blocks).
Jmse 09 01206 g013
Table 1. The detailed specification of parameters in the optical module of the USI system.
Table 1. The detailed specification of parameters in the optical module of the USI system.
ComponentTypeMadeParameterSpecification
LensAutofocusIS STM, Canon, JapanDriveStepper motor
Focus range18–135 mm
Max aperture3.5–5.6
Min aperture22–38
Length/Diameter10 cm/7.6 cm
Lens composition12 groups of 16 lenses
LCTFLyotVis-10
varispec
filter, CRI, USA
Spectral range400–720 nm
Modulation step1 nm
Spectral resolution3.9–18.1 nm
Aperture20 mm
Angular FOV15°
Max flux500 MW/cm2
Response time50 ms
Size9 cm × 5 cm × 5 cm
Imaging
sensor
CCDLm165M,
Lumenera, Canada
CoreMonochromatic 2/3″
Max resolution1390 × 1040
Pixel depth8-bit or 12-bit
Frame rate15 fps
Dynamic range66 dB
Power2.5 W
CommunicationUSB 2.0
Table 2. Specification of parameters in the waterproof mechanical structure of the designed USI system.
Table 2. Specification of parameters in the waterproof mechanical structure of the designed USI system.
ComponentMaterialParameterSpecification
Outer cylindrical case6061-T6 aluminum alloyLength400 mm
Inner diameter160 mm
Wall thickness5 mm
Working depth100 m at 1 Mpa
Max pressure resistance1.80 Mpa
Surface treatmentAnode oxidation
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Song, H.; Mehdi, S.R.; Wu, C.; Li, Z.; Gong, H.; Ali, A.; Huang, H. Underwater Spectral Imaging System Based on Liquid Crystal Tunable Filter. J. Mar. Sci. Eng. 2021, 9, 1206. https://doi.org/10.3390/jmse9111206

AMA Style

Song H, Mehdi SR, Wu C, Li Z, Gong H, Ali A, Huang H. Underwater Spectral Imaging System Based on Liquid Crystal Tunable Filter. Journal of Marine Science and Engineering. 2021; 9(11):1206. https://doi.org/10.3390/jmse9111206

Chicago/Turabian Style

Song, Hong, Syed Raza Mehdi, Chaopeng Wu, Zixin Li, Hai Gong, Amjad Ali, and Hui Huang. 2021. "Underwater Spectral Imaging System Based on Liquid Crystal Tunable Filter" Journal of Marine Science and Engineering 9, no. 11: 1206. https://doi.org/10.3390/jmse9111206

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop