1. Introduction
Growing awareness of global warming and stringent regulations has led to a shift in the global energy market towards renewable energy such as solar, wind and hydropower. Although renewable energy production is increasing, it still accounted only for 14% of the global energy market in 2019 compared to fossil fuels, approximately 80% [
1]. Therefore, it is improbable that renewable energy would replace fossil fuels soon. Thus, to reduce the environmental impact, it is necessary to improve the efficiency of the already existing combustion systems.
One of the most widely adopted combustion systems is the gas turbine, which plays a preeminent role in aviation and energy production [
2,
3]. The gas turbines provide continuous combustion and follow the Brayton cycle [
4]. The cycle involves isentropic (constant entropy) compression and expansion and isobaric (constant pressure) heat addition and rejection. The actual cycle involves further losses like mechanical, aerodynamical, heat release, and pressure drop, reducing the gas turbine efficiency and increasing environmental impacts. Hence, these losses must be minimised.
Among the most influential parameters that affect the efficiency is the turbine inlet temperature (TIT) [
5]. This temperature is constrained by the turbine vanes and blades ability to withstand the arduous operating conditions. These components are pushed to the limit of what the materials can endure in modern gas turbines, withstanding temperatures exceeding 1700 °C [
6,
7]. Thus, sophisticated cooling techniques are required to ensure that the blades and vanes can function under the immense thermal loads [
8,
9]. For instance, minor variations in the inlet temperature could significantly impact the lifespan of these components [
10]. Therefore, it is critical to have adequate tools to predict the heat transfer mechanism in the vanes so that the design can be optimised.
Due to the complexity of gas turbines, it is challenging to obtain experimental results on these effects. Hylton et al. [
11,
12] were able to investigate this phenomenon; the other alternative would be computational fluid dynamics (CFD). Unlike expensive experimental investigations, CFD can provide detailed approximations of complex fluid flows with a reasonable computational cost. With the recent advancements in computer power, CFD has become more accurate, making it an indispensable tool for solving heat transfer problems.
Conjugate heat transfer (CHT) analysis is frequently used in CFD to predict the heat transfer mechanism between the hot gases and materials. The CHT couples interact between the conduction (solid body) and the convection (fluid flow). A coupled aerodynamic and thermal numerical approach for gas turbines was developed by Bohn et al. [
13,
14] in the early 1990s. Using the exact discretisation and numerical scheme for both the fluid flow and the solid body, the heat flux between the two regions becomes interchangeable. Thus, information about heat transfer coefficients on the solid surface is irrelevant, and the temperature distribution in the solid is a direct result of the analysis. The CHT approach has been used to validate 3D computations on the NASA C3X vane [
15]. A comparison of conjugate and nonconjugated heat transfer has been performed [
16], and a decoupled approach has been explored [
17]. Subsequently, the CHT method has been established as an essential tool for turbomachinery optimisation and design purposes.
The famous NASA C3X turbine guide vane [
11] has been used in numerous studies to investigate different cooling techniques. It has been proved that the location, cross-section and mass flow rate of the cooling arrangements are highly influential on the temperature distribution in the vane [
18]. Other studies have included thermal barrier coating, the effects of turbulence intensity and material selection [
19,
20]. Recent developments have suggested replacing compressed air with steam because of its superior heat transfer capabilities. In combined-cycle power plants, steam is easily accessible through the secondary steam turbine, which could be used on closed-loop cooling systems. As a result, the turbine efficiency is increased and also overall combined-cycle thermal efficiency is enhanced. The primary objective of this study is to investigate the effects of replacing compressed air with steam as a coolant in a turbine guide vane.
2. Mathematical Model
In this study, the fluid conjugate flow and heat transfer calculations are performed by the commercial software Simcenter STAR CCM+. The code uses the finite volume approach to solve the Reynolds-averaged Navier–Stokes (RANS) equations with the associated boundary conditions. The Favre-averaged governing equations are derived from three conservational laws; conservation of mass, momentum and energy [
21]. These equations are as follows.
The
operator represents a Reynolds operator (time-average), while the
denotes the density weighted flow variables. The variables,
,
u,
p and
E represents the density, velocity, pressure and the total energy of a fluid, respectively. The term
is the shear stress tensor and is expressed by
where
is the dynamic viscosity, and
is the Kronecker delta.
is the rate of strain tensor and is written as
The heat flux,
, is expressed by Fourier’s law of conduction [
22]
where
is the specific heat capacity,
T is the temperature and
is the dimensionless Prandtl number. The expression for the turbulent stress tensor
, and the turbulent heat flux
, bear some resemblance to Equations (4) and (6) but do have some decisive differences.
The turbulent viscosity
is estimated using turbulence models, while the turbulent Prandtl number
is usually assumed to be constant [
23].
Turbulence Modelling
In RANS methodology, it is crucial to employ turbulence models to anticipate the turbulent flow pattern, and several different models have been developed to provide accurate approximations of the turbulent flow. The
model [
24] and the
model [
25] are two of the most popular turbulence models in CFD. Both models have some limitations when applied to CHT simulations in turbomachinery. The
model is inadequate for separated flows (e.g., airfoils), while the
model is very sensitive to inlet- and free-stream boundaries [
26].
To address these issues, Menter [
27] developed the shear stress transport (SST)
model. The model adds an additional cross-diffusion term, which contains the scalar product of the turbulent kinetic energy
k, the specific dissipation rate
, and a blending function that incorporates the cross-diffusion term far from the walls but not near the walls. As a result, the model behaves as
in the free-stream and
near the walls. Consequently, the SST
model is frequently used in simulations containing flow separation and large pressure gradients. Zheng et al. [
28] compared the commercially available turbulence models against the experimental results by Hylton et al. [
11], and the conclusion presented the
turbulence model [
27] as the most accurate; hence it is the selected model for this study.
The turbulent viscosity
is calculated from
where
k is the turbulent kinetic energy and
I represents the turbulent time scale which is expressed as
where
denotes the specific dissipation rate,
S is given by Equation (
5), and both
and
are model coefficients.
is a blending function which is calculated as
where
is a coefficient,
d is the wall distance, and
is the kinematic viscosity. The transport equations for the turbulent kinetic energy
k and the specific dissipation rate
are
,
,
and
are model coefficients, while the two production terms,
and
are expressed as
Equations (14) and (15) contain the additional coefficients
and
. The term
is another blending function defined as
where
represents the cross-diffusion coefficient. All the coefficients and their formulations as summarised in
Table 1.
3. Experimental Details
In this study, one of the two aerothermodynamic investigations presented by Hylton et al. [
11] is used to validate the numerical model. The objectives of the original report were to acquire experimental data to verify the results of a 2D heat transfer modelling technique. In the original experiments, three C3X turbine guide vanes are located in a free stream. The centre vane is subjected to evaluation, while the two adjacent slave vanes are included to ensure steady-state aerodynamic conditions. The test vane is convectively cooled by ten radial cooling passages from the hub to the shroud. The passages have circular cross-sections and are supplied with air from individual metered lines. The geometric configuration of the vane is adopted from the experimental report [
11], where the constant cross-section is located in the x-y plane, as shown in
Figure 1. The height of the vane is 76.2 mm, and it has no twist. It is observed that the cooling holes are arranged according to the curvature of the centerline, except the holes near the leading edge. The geometrical specifications of the vane are summarised in
Table 2.
The test section contains turbulence augmentation rods, followed by static pressure taps, located 187.2 mm from the leading edge of the vanes. The next exit static pressure taps are located 90.2 mm from the leading edge. The walls are cooled using steam to prevent heat radiation and keep the temperature similar to the vane surface temperature. Therefore, the walls are considered to be adiabatic. The inlet of the computational model coincides with the inlet pressure taps. The outlet is located further downstream to eliminate the effects of turbulence. Due to periodicity, the mainstream is restrained by two planes separated by 117.73 mm in the y-direction, which follows the centre-curvature of the vane. This will also reduce the computational demand of the simulations. To ensure fully developed flow and eliminate unwanted effects, such as reversed flow, both the inlet and outlet of the cooling channels are extruded 50 mm. A schematic of the computational models with boundaries is shown in
Figure 2.
The experimental data were obtained in the original study by instrumenting the test vane with approximately 80 thermocouples and 30 static pressure taps. The thermocouples were located at a plane near the midspan of the vane and were placed in 0.58 mm deep radial grooves. The grooves were then covered by cement and blended by hand to ensure a smooth surface. To minimise the errors from the grooves, the vane was made of ASTM310 type stainless steel, with a relatively low thermal conductivity. Similarly to the thermocouples, the static pressure taps are mounted near the midspan. The distribution of the pressure taps is denser near the leading edge to adequately capture the large pressure gradients in this area. The installation of the pressure taps was performed similarly to the thermocouples. Each of the cooling channels was instrumented with thermocouples and static pressure taps at the inlet and the outlet. The temperature measurements on the vane surface are specified as a well-developed technique, with a proclaimed uncertainty of ±1 °C. The free-stream temperature measurements had a reported uncertainty of ±11 °C, due to the fluctuations from the facility combustor. As a result, the calculations of the heat transfer coefficients are severely affected by this. The pressure measurements were described with an uncertainty of ±0.7 kPa.
5. Model Validation
To assess if the results generated by the computational model is reliable, a comparison against the experimental results by Hylton et al. [
11] is performed. The dimensionless location
is used to show the position on the external wall of the vane. It is derived from the x-coordinate of the data points (
X) and the axial chord length (
L). The dimensionless location is also used to differentiate the pressure side (PS) and the suction side (SS). The leading and the trailing edges are represented by
= 0 and
= 1 or −1, respectively. The pressure and temperature distribution is normalised by
and
, using the reference values reported in [
11].
The static pressure distribution at mid-span is used to compare the aerodynamic characteristics of the vane. It is observed that the numerical results on the pressure side
are in excellent agreement with the experimental results, as shown in
Figure 5. On the pressure side, it is observed that the pressure declines slowly until
= −0.5, and then it drops drastically. When the flow is approaching the trailing edge (
= −1), the static pressure begins to fluctuate. The more complex flow behaviour leads to discrepancies between the experimental and numerical results on the suction side. From the leading edge, the flow is accelerated on the suction side. In the region where
is between 0.3 and 0.7, the numerical model overpredicts the acceleration. This anomaly could be explained by the turbulence model ability to consider all the complex flow phenomenon, particularly for flows with strong acceleration. However, the numerical results are still in overall good agreement with the experimental results, with an average error of 1.39%.
Figure 6 shows the normalised temperature at mid-span and is used to validate the thermal effects of the flow. It is recognised that the predicted temperature on the pressure side is slightly overpredicted but is in alignment with the experimental results. From the leading edge, the temperature is decreasing steadily until
= −0.5. After this point, the temperature is increasing but is suffering from some local drops. These drops coincide with the position of the cooling channels, which are increasingly influential when the thickness of the vane is decreasing. As expected, the maximum temperature appears around the trailing edge, where the thickness is slim. Similarly to the pressure distribution, the temperature on the suction side of the vane is showing a clear distinction between the numerical results and the experiment, especially when
is between 0.1 and 0.6. Nevertheless, the two results are in good agreement with an average relative difference of 3.78%.
In order to obtain a better understanding of the discrepancies, a figure displaying the contours of the Mach number at the mid-span plane is presented in
Figure 7. It is observed that the flow splits at the leading edge, which is followed by an acceleration on both sides of the vane. On the pressure side, the Mach number increases gradually toward the trailing edge, causing the static pressure to decrease. Near the trailing edge, a sudden surge of the Mach number occurs, which increases the velocity. The flow is then reunited as it passes the trailing edge, causing the reduction of the mach number.
On the suction side, the flow accelerates rapidly toward the throat, and just after the “top” of the vane, the section containing the highest Mach numbers appears. The heat transfer is dependent on the local velocity, which is high in this area. This rapid acceleration causes the heat transfer to increase. Besides, the boundary layer in this region decreases, thus reducing the resistance to heat transfer. Coincidentally, this region corresponds with the deviations observed in
Figure 6. After the high mach number region, the flow is transitioning before separating near the trailing edge. This is shown by a decrease followed by an increase in mach number.
As previously mentioned, the discrepancies on the suction side are connected to the numerical model, specifically the turbulence model. The shortcomings of the turbulence model arise in stagnation regions and regions with steep acceleration [
39,
40], both present in this study. The model tends to overpredict turbulence levels in these regions but still performs better compared to other turbulence models [
28]. By including transition models to the simulations, the discrepancies could be reduced [
41]. However, for the purpose of this study, transition models are not included in the simulations.
6. Comparison of Air and Steam
In this section, a comparison between air and steam as a cooling medium is presented. To better understand how the vane is affected by the cooling mediums, three cross-sectional planes are selected to examine the disparity at different locations. These planes are located at 25%-span, mid-span, and 75%-span, with the hub as a reference, shown in
Figure 8.
The normalised temperature distribution at these sections is displayed in
Figure 9, which is used to study the thermal influence on the external wall of the vane. It is observed that the temperature profiles at the different cross-sections are reasonably consistent, as expected. Apart from the overall temperature, the only other noticeable difference is the fluctuations where
is between
and
on the pressure side and between 0.7 and 1 on the suction side. In all sections, the steam results show a steeper decrease and increase of temperature, and the variation between the bottom and vertex of the fluctuations are significant. This difference indicates that the cooling effects of steam are more significant than air. Besides, it is detected that the difference between the results increases from the hub to the shroud. The average difference between all data points increases from 3.89% to 4.87%; then, it increases to 5.29%. The total increase is 1.6%, which is equivalent to 13 K. This implies that the temperature rise along the vane is slower when steam is used, confirming the previous statement.
Figure 10 displays the temperature contours in the previously defined cross-sectional planes. It is useful to study these temperature contours to get a complete impression of the temperature in the vane. By comparing the air and steam contours, the previously established trend is apparent. The vane gets hotter as the distance from the hub is increased, and steam is the superior cooling medium. The temperature rise in the spanwise direction is due to a decrease in the cooling effect, caused by an increase in the coolant temperature. Additionally, some other details are noticed from this figure. It is observed that the heat transfer on the pressure side is lower compared to the suction side. This is displayed by the “cooler” areas stretching toward the pressure side. In addition, two areas of interest become visible in this figure. Both the “top” of the vane and the trailing edge exhibits high temperatures, suggesting that these areas are prone to high thermal loads.
The static temperature distribution on the external surface of the vane is presented in
Figure 11. It is observed that the maximum temperature, as earlier stated, appears near the trailing edge of the vane. This high temperature is due to the small diameter of the channels, low mass flow rate, and the thickness of the vane. The location of the cooling channels, especially near the trailing edge, is obvious, showing the effect of this cooling mechanism. It is noticed that the cooling channels exhibit wave-like behaviour, which is a result of the thermal energy transferred from the mainstream to the coolant along the axial direction. On the pressure surface, it is noticed that low-temperature zones are formed following the leading edge. This is due to the blade’s profile, where the flow is fully developed, displaying a higher thermal resistance in these zones. As a final observation, steam is yet again proven to be the preferable cooling medium. In fact, the volume average temperature is 30 K lower when using steam.
When steam is used as the cooling medium, the temperature in the vane is reduced; however, the temperature in the external gas path remains unaffected. The exception of this is seen near the trailing edge of the vane, as shown in
Figure 12. It is also observed that the temperature is slightly lower immediately after the trailing edge when steam is used. The steam reduces the temperature in the vane, which affects the hot gas stream near the external wall of the vane. This difference is hard to observe along the vane walls but is visible after the trailing edge when the flows are reattaching.
Most of the flow parameter in the external gas path is very similar, regardless of the cooling medium. One example of this is shown in
Figure 13, where the pressure in the external flow is nearly identical for the two cases. From this figure, it is also noticed that the pressure in the cooling channels is lower when steam is used. In addition, the smallest cooling channels are observed to have a higher pressure. When the temperature is decreased, the pressure will also decrease. Since the smaller channels are more affected by the external hot gas path, the pressure becomes higher, as depicted in the figure.
Two other parameters which are influenced by the temperature are enthalpy and heat flux. The enthalpy in the cooling channels with the two cooling mediums is presented in
Figure 14. It is shown that the enthalpy is increased when steam is used as a cooling medium. In addition, it is noticed that the enthalpy increases along the axial direction of the vane.
Figure 15 is displaying the normalised heat flux at the mid-span of the vane. It is obvious that the heat flux is increased when steam is used as a cooling medium. Both of these parameters are greatly affected by the temperature difference between the hot gas and the cooling medium. When steam is used as a cooling medium, the temperature is decreased. As a result, both the enthalpy and the heat flux is increased.
7. Summary and Conclusions
Three-dimensional conjugate heat transfer analyses have been performed on the radially cooled NASA C3X turbine guide vane, using the RANS based SST
turbulence model. The objective was to evaluate the effects of steam as a cooling medium compared to the traditional compressed air coolant. The computational model was validated against experimental results [
11]. The aerodynamic and thermal characteristics were in good agreement with the experimental results, where the average relative difference was 1.39% and 3.78%, respectively.
The steam was proven to be the superior cooling medium, as expected. The temperature distribution of the two coolants displayed the same trends in the defined cross-sectional planes. Additionally, it was observed that the difference between the mediums increased along the axial direction of the vane. The average difference increased from 3.89% at the 25%-span to 5.29% at the 75%-span, which is equivalent to an increase of 13 K, solidifying steam as the preferable coolant.
Finally, it was shown that both the air- and steam cooled vane had some local areas with high temperatures. The low cooling effectiveness in these areas may lead to undesirable thermal loads and thermal stresses, contributing to a reduced lifespan of the vanes. Thus, further investigations are recommended to optimise the geometrical configuration and the mass flow rates of the cooling channels.