1. Introduction
Measuring air permeability is important to evaluate whether a textile fabric is suitable for different applications, from clothing to diverse technical textiles [
1]. Usually, this value is measured by testing the air flowing through a defined fabric area within a defined time under the impact of a defined pressure (e.g., 100 Pa), a definition which has been used since the middle of the 20th century [
2,
3,
4]. Test procedures based on this principle are described in several standards with slightly varying parameters, e.g., EN ISO 9237 (Textiles—Determination of Permeability of Fabrics to Air [
5]), ASTM D737-75 (Standard Test Method for Air Permeability of Textile Fabrics [
6]), or ASTM F778-82 (Standard Methods for Gas Flow Resistance Testing of Filtration Media [
7]).
While measurements according to these standards are regularly reported in the recent literature [
8,
9,
10], the test instruments are relatively expensive and not easy to build, impeding many small companies and research groups from measuring air permeability. An alternative test procedure, which was already suggested in 1932, is based on the principle of a falling cylinder, where a cylinder falls down due to gravity and by this pulls air through textile fabric of a defined area [
11]. A slightly different principle was patented by Kawabata, who led a falling piston press air through the specimen under investigation and measured the built-up pressure [
12], similar to Wagner and Cain [
13] and Wang et al. [
14] who also used gravity to move a piston against the air pressure built in a chamber which was closed from the outside by a textile fabric. A slight variation in this principle was suggested by Lyu et al. who described a similar system in which pressure was built up by a pump [
15].
Recently, we built an inexpensive air permeability test stand based on the falling piston principle and showed that longer falling times were well correlated with smaller air permeability, as could be expected [
16]. However, besides the necessity to regularly add lubricant in order to reduce the friction between the piston and the cylinder in which it is falling, no simple correlation between falling duration and air permeability can be expected. On the other hand, a testing instrument, according to the simple physical idea that increased air flowing through the textile under examination will increase the speed of the falling piston, can be built much more easily than the common instruments according to EN ISO 9237 and would thus enable more companies and research groups to measure air permeability in an inexpensive way. Here, we thus describe recent improvements of the lubricant, give results of a larger test series comparing the custom-built test stand with a commercial air permeability tester, and finally calculate the correlation between the falling duration and the standardized air permeability.
2. Materials and Methods
The custom-made air permeability tester consists of a long transparent tube in which a stainless steel piston (mass 2272 g, diameter 94 mm, height 77 mm) can glide down. The overall mass of the piston can be increased by up to 6 additional weights (232 g each). Gaskets around the piston impede air from flowing between piston and tube; they have to be treated by a lubricant to reduce friction. The time which the piston needs to fall from one inductive sensor (40 cm below the starting position) to the next one (40 cm below the first sensor) is measured.
The upper end of the tube has a round open area (10 cm
2, identical to a value specified in EN ISO 9237) in which the textile fabric under examination can be clamped; the lower end is open. To perform a measurement, the piston is introduced into the tube, the latter is rotated by 180° so that the piston glides to the top where it is hold by an electromagnet, the tube is rotated back, and the electromagnet is switched off to release the piston whose falling duration between both inductive sensors is measured. If a textile fabric with low air permeability is investigated, the reduced pressure above the falling piston will reduce its velocity. A more detailed description of the test stand can be found in Ref. [
16]; the test stand is shown in
Figure 1. Its working principle is based on the idea that the falling piston drags air through the textile specimen under investigation and uses the underpressure built up by this process to measure the air permeability. Briefly, an open-pore fabric which has maximum air permeability will not build up a partial vacuum and thus not reduce the piston’s falling speed, while a nearly completely closed textile fabric will only enable air to penetrate slowly, so that a partial vacuum builds up over the falling piston which will reduce its velocity.
Measurements were performed for 0, 3 and 6 additional weights, respectively. As lubricants, Ballistol universal oil and PTFE spray (both from Ballistol, Aham, Germany) were tested. Each experiment with Ballistol universal oil was performed 10 times, while experiments with PFTE spray were performed 5 times each due to their smaller standard deviations. Generally, a suitable lubricant is necessary to reduce the friction between the gaskets and the tube, while at the same time ensuring air-tight contact between gaskets and tube.
Experiments were performed at 22 °C and a relative humidity of 35–38% as no climatized laboratory was available.
For comparison, the commercial air permeability tester FX 3300 Lab Air IV testing instrument (Textest AG, Schwerzenbach, Switzerland), working according to EN ISO 9237, was used (number of measurements per sample n = 3).
The textile fabrics under examination are depicted in
Table 1. They were chosen as to represent a broad range of different structures, materials and corresponding air permeabilities. Microscopic images were taken with a digital microscope VHX-970FN (Keyence, Neu-Isenburg, Germany).
3. Results
Firstly, experiments were performed using Ballistol universal oil as lubricant, as in the previous tests [
16]. With this lubricant, tests without additional weights were not possible as the piston regularly became stuck in the tube.
Figure 2a thus shows only the results with 3 and 6 additional weights, respectively.
In most cases, the error bars (indicating the standard deviations) are relatively small, showing the high reliability of the measurements. The longest time was measured for sample 10, i.e., this sample should have the lowest air permeability, while samples 5 and 12 have the highest air permeability. It must be mentioned here that the air permeability is not directly proportional to the thickness, mass per unit area or the cover factor of a fabric, so that the microscopic images or areal weights in
Table 1 cannot be used for a calculation of the air permeability or falling time.
The correlation between measurements with three and with six additional weights is given in
Figure 2b. For most measured falling durations, a linear correlation between both values exists; only the longest falling time deviates from this correlation. This can be explained by the slow movement of the gasket through the tube being more influenced by friction, with stick-slip friction as the extreme case; here, apparently the three additional weights are insufficient to fully overcome the friction between gasket and tube.
Next,
Figure 3a depicts measurements performed after fully cleaning the whole test stand from Ballistol universal oil and using PTFE spray as a lubricant instead. With this spray, it was also possible to the piston without an additional weight, indicating that PTFE spray can reduce the friction between piston and tube more reliably. Again, sample 10 shows the longest falling time, i.e., the smallest air permeability, again followed by samples 4, 6 and 1. The shortest times, i.e., highest air permeabilities, can again be found for samples 12 and 5. Nevertheless, the ratios between the falling times for different samples or varying numbers of additional weights are different from those measured with Ballistol universal oil. This leads to the question which measurements—with universal oil or with PTFE spray, and with 0, 3, 6 or another number of additional weights—correlates best with the air permeability measured with a standardized testing instrument.
The correlation between measurements with three and with six additional weights for PTFE spray as the lubricant is shown in
Figure 3b. Here, the linear correlation also persists for the longest falling time, underlining that PTFE spray leads to more reliable results in a broader range of air permeabilities. The comparison of these values with those taken in measurements without additional weights reveal a much worse correlation, indicating that even with PTFE spray, at least three additional weights should be used.
For the comparison of the values taken with the custom-made air permeability tester, all samples have also been investigated with a commercial air permeability tester according to EN ISO 9237. The results are depicted in
Figure 4.
Figure 5a shows the measured falling times of the custom-made testing instrument vs. the air permeability measured using the standardized testing instrument. Generally, a correlation similar to 1/x is visible, with larger air permeabilities correlated to smaller falling times and vice versa. However, this graph is not suitable to differentiate between 1/x, 1/x
2 or similar correlations.
Figure 5b thus depicts the measured falling times vs. the inverse of the air permeability, as measured using the standardized testing instrument. Here, the measurements with PTFE spray and three or six additional weights especially show an approximately linear correlation, while the measurement with PTFE spray without additional weights shows several outliers, suggesting not using this setup. For the smallest air permeabilities, however, all measured falling times are longer than expected for a simple linear correlation. The next section will thus discuss the correlation between both values, as it can be expected due to fluid dynamic calculations.
4. Discussion
This section shows a simplified calculation method to estimate the air permeability from the measured falling times.
To transfer the measured values of the custom-made testing device to the commonly used air permeability of textile fabrics according to EN ISO 9237, a simplified first approach will be shown. The approach presented pursues the goal of firstly calculating the pressure loss coefficient of the inserted sample in terms of plant engineering and pipeline construction. To accomplish this, a couple of assumptions are necessary. Afterwards, by using the same equation as before with different parameters in an imaginary device, one can now calculate the velocity of the airstream perpendicular to the surface of the sample.
The following text uses the simplified test setup shown in
Figure 6 to illustrate the calculation method. The whole setup is rotated by 90° for better visibility.
As already mentioned, the required equations are only valid under certain assumptions which will now be presented. First of all, the friction in two aspects has to be set to zero.
One aspect is the friction between the piston and the cylinder, so that the coefficient of kinetic friction is zero:
The second aspect is the inner friction of the fluid so we assume an inviscid flow:
Another property of the fluid is the constant density, so there is no change in space or time:
Furthermore, the piston has to be in force equilibrium (
), which equals to a constant piston velocity:
between the two measurement points where the falling time is measured.
With the assumptions introduced, we are able to estimate the pressure loss coefficient of the sample using the Bernoulli equation including one loss term.
Figure 7 includes the necessary quantities in our system and their positions.
As seen in
Figure 6, a movement of the piston with mass
in positive x-direction with the velocity
results in fluid flow through the sample inside the chamber between sample and piston. Since we work exclusively with the x component, we do not use vector notation for the velocity or any forces in the following. For simplification, we assume a uniform velocity field over the two relevant diameters, the piston diameter
and the sample diameter
. The dashed arrows are intended to represent the velocity field with
for the velocity inside the chamber and
for the velocity at the sample diameter. Because of the uniform velocity field at
, the flow velocity is the same as the piston velocity
.
The dotted line is an example of a possible streamline and is used in the following. If fluid flows along this dotted line, it has to overcome three main obstacles. Each of these obstacles has its own pressure drop coefficient
. Two of them are well known and the pressure drop coefficient can be taken from the specialized literature. The first one is the scenario “flow from a tank into a pipe”. The pressure drop coefficient for a sharp edge on the inlet side is
[
17]. The second well known is the Borda–Carnot diffusor, when the fluid leaves the sample holder and the diameter of the cross-section expands from
to
. The pressure drop coefficient can be calculated with the following formula [
17]:
The pressure drop over the whole sample holder
can be calculated as mentioned above with the Bernoulli equation including one loss term. Restriction to one loss term is possible, because all terms use the same reference velocity
.
Because of the small difference in height between the two points under consideration, both in the schematic representation and in the real experiment, the energy term based on height difference is neglected. The main target at this point is to separate the pressure drop coefficient
for the sample. Rearranging Equation (6) gives the following:
The unknown quantities are the velocity
and the pressure difference
. The flow velocity at the sample can be eliminated by the law of continuity and replacing it with the known piston velocity
:
Since the piston is in force equilibrium, the gravitational force
is equal to the force
introduced by the pressure difference between the chamber and the surroundings:
These terms can be rearranged to an expression for the pressure difference.
Now the unknown terms in (7) are replaced with (8) and (9):
With this equation, the pressure loss coefficient of the sample in this specific configuration can be determined.
At this point, a change in setup is required. A new imaginary testing device is needed whose parameters are set to values like the standard EN ISO 9237 uses. The new test environment is required to apply the pressure difference from the EN ISO to the sample in an imaginary test in order to determine the velocities in accordance with EN ISO without any other obstacles in terms of fluid dynamics. So, the new imaginary device is just a pipe with the sample mounted in the pipe, without any steps or other disturbances. As mentioned, Eq. 6 is used again, but with only one pressure loss coefficient, the one from the sample and the pressure difference from EN ISO 9237. Rearranging leads to the velocity perpendicular to the desired value, which is the velocity perpendicular to the sample surface induced by the pressure difference according to the EN ISO 9237. For this purpose, the setup in
Figure 8 is used.
The diameter of the effective cross section stays the same as in the testing device before, but the pressure difference is now taken from the EN ISO 9237 (
). Again, the Bernoulli equation is used, but this time the only pressure drop coefficient is the one from the sample.
The value of interest is the velocity
perpendicular to the sample surface which corresponds to the
value from the EN ISO 9237. Rearranging the equation results in the following:
The pressure loss coefficient
can be replaced by the derived Formula (10), and inserting it into (11) leads to the following:
The result of Equation (12) is the permeability of the sample in meters per second and should give a good first estimation for the comparison of the measured time (here visible in the form of the constant velocity v1) with the result of a standardized test instrument.
In this calculation, several assumptions have been made which have to be discussed.
As usual, the calculation method, neglecting friction, is only a first attempt to harmonize data or procedures. In the future, it should be tested whether it is possible to adjust the values of the new test device to the values of the standard-compliant test device using simple correction terms in the calculation formula.
Also, the components for the pressure loss coefficient were treated as separate, but due to their spatial proximity they are more likely to be categorized as one component, which means that the calculation may be incorrect.
It should also be checked whether the pressure difference or the flow velocity is in the order of magnitude of the standard-compliant test device. It is not certain whether the pressure difference across the sample increases quadratically with the velocity. There may well be a different correlation, but the error can be minimized by adjusting the speed of the new test device so that the pressure difference from the standard is approximately present. Also, there could be phenomena such as choking, well known from other flow-through components.
To test whether the above equation approximates the measured values of the custom-made test device,
Figure 9 depicts theoretical vs. measured values of the air permeability.
For small values of the air permeability, measurements with Ballistol universal oil give too high calculated air permeability values, while the values calculated from the falling times measured with PTFE spray are similar to those measured with the standardized instrument. For higher air permeabilities, however, the calculated values are in both cases lower than those measured with the standard test procedure. Most importantly, both values are approximately linearly correlated for air permeabilities around 0–500 L/(m2s), allowing a simple conversion by a constant conversion factor. However, there are more measurements needed in the range around 500–3500 L/(m2s) to investigate in which range of value there is a linear correlation, and how higher air permeabilities—where the friction apparently has a larger impact—can be correlated between both measurement methods.
As discussed above, several factors may explain the deviation from the consistency of the values measured with the standardized instrument and those ones calculated from measurements with the custom-made testing instrument. Especially for high air permeability, the velocity of the falling piston is possibly not yet constant. On the other hand, high air permeabilities, such as 3500 L/(m
2s), are also near the upper limit of the measurement range of the commercial device, so that here potentially larger errors occur than in a middle range of 10–1000 L/(m
2s), in which the automatic measurement range matching stays in one of the middle measurement ranges [
16].
While a correlation between both measurements methods has been clearly shown, these deviations necessitate further experiments and simulations of both instruments to investigate correlations and differences more in detail. Furthermore, to improve the repeatability of measurements with such simple air permeability testers produced at different universities or companies, three to five test standards should be defined in the form of masks with defined dimensions and hole geometries, which all researchers can have produced in a simple way in a metal workshop; 3D printed parts should not be used here to avoid the usual dimensional deviations depending on printers, printer settings and printed materials.