Correction: Norjeli et al. Additive Manufacturing Polyurethane Acrylate via Stereolithography for 3D Structure Polymer Electrolyte Application. Gels 2022, 8, 589

by
Muhammad Faishal Norjeli
1,
Nizam Tamchek
2,
Zurina Osman
3,
Ikhwan Syafiq Mohd Noor
4,
Mohd Zieauddin Kufian
3 and
Mohd Ifwat Bin Mohd Ghazali
1,*
1
SMART RG, Faculty of Science and Technology, Universiti Sains Islam Malaysia, Nilai 71800, Malaysia
2
Department of Physics, Faculty of Science, Universiti Putra Malaysia, Serdang 43400, Malaysia
3
Centre for Ionics Universiti Malaya, Department of Physics, Faculty of Science, Universiti Malaya, Kuala Lumpur 50603, Malaysia
4
Physics Division, Centre of Foundation Studies for Agricultural Science, Universiti Putra Malaysia, Serdang 43400, Malaysia
*
Author to whom correspondence should be addressed.
Gels 2024, 10(7), 423; https://doi.org/10.3390/gels10070423
Submission received: 16 April 2024 / Accepted: 17 April 2024 / Published: 27 June 2024
(This article belongs to the Special Issue Functional Transformations in Polymer Gels)
In the original publication [1], there was a mistake in Figure 11 as published. There was a mistake on the y-axis of the graph in Figure 11. The corrected Figure 11 appears below.
The authors state that the scientific conclusions are unaffected. This correction was approved by the Academic Editor. The original publication has also been updated.

Reference

  1. Norjeli, M.F.; Tamchek, N.; Osman, Z.; Mohd Noor, I.S.; Kufian, M.Z.; Ghazali, M.I.B.M. Additive Manufacturing Polyurethane Acrylate via Stereolithography for 3D Structure Polymer Electrolyte Application. Gels 2022, 8, 589. [Google Scholar] [CrossRef] [PubMed]
Figure 11. Thermograms of 3DP GPE PUA with different wt.% of LiClO4.
Figure 11. Thermograms of 3DP GPE PUA with different wt.% of LiClO4.
Gels 10 00423 g011
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Norjeli, M.F.; Tamchek, N.; Osman, Z.; Mohd Noor, I.S.; Kufian, M.Z.; Ghazali, M.I.B.M. Correction: Norjeli et al. Additive Manufacturing Polyurethane Acrylate via Stereolithography for 3D Structure Polymer Electrolyte Application. Gels 2022, 8, 589. Gels 2024, 10, 423. https://doi.org/10.3390/gels10070423

AMA Style

Norjeli MF, Tamchek N, Osman Z, Mohd Noor IS, Kufian MZ, Ghazali MIBM. Correction: Norjeli et al. Additive Manufacturing Polyurethane Acrylate via Stereolithography for 3D Structure Polymer Electrolyte Application. Gels 2022, 8, 589. Gels. 2024; 10(7):423. https://doi.org/10.3390/gels10070423

Chicago/Turabian Style

Norjeli, Muhammad Faishal, Nizam Tamchek, Zurina Osman, Ikhwan Syafiq Mohd Noor, Mohd Zieauddin Kufian, and Mohd Ifwat Bin Mohd Ghazali. 2024. "Correction: Norjeli et al. Additive Manufacturing Polyurethane Acrylate via Stereolithography for 3D Structure Polymer Electrolyte Application. Gels 2022, 8, 589" Gels 10, no. 7: 423. https://doi.org/10.3390/gels10070423

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop