Next Article in Journal
The Impact of Possible Mercury Source-Point Contamination in the Coastal Area of Skiathos Island
Previous Article in Journal
Pressure-Driven Simulation of Water Distribution Networks: Searching for Numerical Stability
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Proceeding Paper

Design of Reliable and Efficient Banki-Type Turbines †

1
Department of Engineering, University of Palermo, 90128 Palermo, Italy
2
National School of Engineers of Sfax, University of Sfax, Sfax 3038, Tunisia
*
Author to whom correspondence should be addressed.
Presented at the 4th EWaS International Conference: Valuing the Water, Carbon, Ecological Footprints of Human Activities, Online, 24–27 June 2020.
Environ. Sci. Proc. 2020, 2(1), 49; https://doi.org/10.3390/environsciproc2020002049
Published: 5 September 2020

Abstract

:
A new shape for the external surface of the Crossflow turbine blades is proposed, which allows for the preservation of hydraulic efficiency in spite of a significant maximum blade thickness providing mechanic robustness and reliability. The final shape of the blades is assessed using an iterative solution for two uncoupled models: a 2D computational fluid dynamic (CFD) and a structural 3D finite element method (FEM) analysis of a single blade. Application of the proposed methodology to the design of a power recovery system (PRS) turbine, a new backpressure Crossflow-type inline turbine for pressure regulation, and energy production in a real Sicilian site follows.

1. Introduction

Energy recovery from mini-hydro turbines with positive outlet pressure installed in transport and distribution water pipes has recently gained major attention in the scientific literature, especially when the device can supply the same function as the valves [1]. These turbines are usually pumps used in reverse mode (pumps as turbines, PATs, see [2]), bulb types [3,4], or Crossflow-type turbine [5,6], like the power recovery system (PRS) [7,8,9]. The main advantage of the PRS, with respect to the other types of turbines, is that it has the capacity for hydraulic regulation by means of a mobile flap that can change the characteristic curve of the turbine, while still maintaining good efficiencies within a large range of head jumps and flow rates (see in Figure 1 a section of the PRS normal to the turbine axis). Design criteria for the impeller diameter and the width B can be found in [7,8,9].
In the design of Crossflow-type turbines, major attention is given to the maximization of hydraulic efficiency [10]; on the other hand, mechanic failure of the turbine impeller is quite common in practice, due to the heavy loads and to the reduction of the maximum admissible stress occurring in a very short time as a result of the high frequency of the impeller rotation (500–1000 rpm). For this reason, reliable machines made with traditional materials require significant thickness of the blades, which is not ably larger than the thicknesses often used in laboratory or numerical experiments.
In the following sections, it is first shown, using simplified 2D simulations and a constant curvature of both the internal and the external surface, that the maximum efficiency is obtained when the external surface of the blade is tangent to the external circle of the impeller, but the corresponding maximum thickness may not be sufficient to guarantee mechanical safety. To maintain the same condition with a higher maximum thickness, it is necessary to move from a quadratic to a cubic shape of the external surface.
In the proposed design procedure, the external impeller radius, its width, and its rotational velocity are computed using the methodology already proposed in [5]. The maximum thickness of the blades, their shape, the number of blades, and the possible allocation of an intermediate septum along the blade width are selected using an iterative procedure. The procedure starts from computation of the blade shape corresponding to a given maximum thickness, using a cubic function and the following conditions: a small initial and final thickness, measured along the radial direction of the internal surface with a circular profile, the maximum thickness value, and its derivative value at the external end according to the previously cited tangent optimality condition. The maximum pressure field acting on the surface of a single blade is then computed by solving a simplified 2D computational fluid dynamic (CFD) problem: using the computed pressure field, a finite element method (FEM) structural analysis, where the 3D effect of the blade constraints is accounted for, is solved for a single blade. After the iterative procedure attains stresses below the maximum allowed values, a fully 3D CFD simulation is run, along with a FEM structural analysis of the entire impeller.

2. Blade Design

The internal blade surface is simply designed as part of a cylinder, with the axis parallel to the impeller axis and its trace on the normal plane located at the intersection of the two directions orthogonal to the inlet and outlet relative velocities, as shown in Figure 2 and Equations (1), where V is the velocity norm, D and Di are the impeller outer and inner diameter, respectively, α is the attack angle of the entering particles, and ω is the rotational velocity of the impeller. The exit angle β2 is set equal to 90°. The inlet angle β1 is set in order to guarantee the tangent condition of the relative velocity at the intersection P of the impeller outlet surface and the internal blade surface.
    ρ b = D 4 [ 1 ( D i D ) 2 ] c o s ( β 1 ) 1 β 1 = a r c t a n V s i n α V c o s α ω × D 2 t a n ( θ 2 ) = c o s β 1 s i n β 1 + D i D
In Table 1, see all the parameters of a PRS turbine, marked as PRS1, designed assuming a circular profile of the external surface, and in Figure 3, for each possible φ value, the corresponding efficiency. The two ends of the circular profiles have been smoothed using a circular connection with a radius equal to 0.1 times the maximum thickness. We can observe in Figure 3 that the maximum efficiency is attained for φ = β1, corresponding to an external surface tangent to the impeller circle. The same optimality condition is also obtained in other tests (not documented here for brevity) using different design parameters for the turbine. The reason is likely to be the maximum reduction obtained for the actual α attack angle of the entering particles, occurring along a large part of the inlet surface of each channel.
Let us call tmax,opt the maximum thickness corresponding to the tangent condition. Note that if this thickness is not sufficient for the blade’s structural resistance, since the maximum von Mises stresses are not lower than the admissible limits, the condition of maximum efficiency will be lost due to the need for a more robust design.
The previous results show how the simple criterion of the maximum efficiency can lead to poor mechanical design. To avoid that, we change the external surface moving from a second-order (circular) profile to the following third-order (cubic spline) profile:
t ( δ ) = a δ 3 + b δ 2 + c δ + d
where t is the thickness measured along the radial direction of the internal surface and δ is the angle between the radial direction and the direction orthogonal to the internal surface at the inlet point (Figure 4a). Coefficients a, b, c, and d are computed by setting the following conditions:
(1) t’(δmin) = tan(β1min); (2) t(δmin) = t0; (3) t(θ) = tmin; (4) t(δ*) = tmax; (5) t’(δ*) = 0
where tmax is the maximum thickness of the blade, tmin is the thickness at the outer blade extremity, t’ is the derivative with respect to δ in the interval [δmin; θ], tmin is set equal to 0.1 tmax, and δ* is a fifth auxiliary unknown.
δmin and t0 are computed by setting the tangent condition to the outer impeller surface and assuming a circular profile with radius rf for the inner blade extremity, tangent in P1 to the cubic spline profile of the external surface and in P2 to the circular profile of the internal surface (Figure 4b). rf is set equal to 0.1 tmax.
Conditions 1–5 make it possible to maintain the tangent condition of the external surface to the outer impeller circumference for different possible values of the maximum thickness. Figure 5 shows how the cubic profile makes it possible to maintain a much higher efficiency while changing the tmax maximum thickness value.

3. Fluid Dynamic Investigation

Optimal impeller design could be achieved through a set of 3D CFD simulations and associated FEM analyses. However, this approach is computationally burdensome and would take many weeks or months of numerical calculation using standard computational resources. For example, a 3D CFD solution of a single configuration of the PRS1 turbine (Table 1) required 15 days of transient simulation, using ANSYS® CFX commercial code and parallel processing on several CPU Intel® Xeon(R) E5-2650 v3 machines.
Due to the symmetry of the impeller with respect to a plane normal to its axis, the difference between the 2D and the 3D solution of a Banki turbine is usually small; this difference is even more negligible if the purpose of the simulation is to compare the efficiencies of two or more impeller geometries. Adopting the 2D assumption, the velocity and the pressure field of the same PRS1 turbine was obtained with a computational time of only 20 h. Figure 6 shows the velocity field in the symmetry plane of the 3D simulation (left) and the same field obtained by 2D simulation (right). The results show good matching for the accuracy required by the iterative design problem.

4. Fluid Dynamic Investigation

The total power available at the turbine shaft is obtained by summing the torque of each individual blade multiplied by the rotational velocity of the impeller.
Let us define τ as the ratio between the torque in the axis of the turbine provided by a single blade and the theoretical total torque, which is as follows:
τ = ω T b l a d e γ Q Δ H
In Crossflow impellers, the torque of the blades is not the same at a given time because it depends on the position of the blade itself.
Let us call τmax the maximum occurring t value. Using several CFD 2D test cases, not documented here for brevity, the behavior of this parameter was analyzed as a function of the number of blades of the impeller, within the range of 22–35 suggested by most of the authors. The results obtained for two different impellers provide a τmax value of about 0.12, which slowly decreases with an increasing number of blades.

5. Optimal Impeller Design

The optimal CFD and structural impeller design can be obtained by the following iterative procedure:
  • Choose the minimum reliable value for the maximum blade thickness tmax as the initial tentative value.
  • Compute the blade profiles according to the procedure explained in the previous section.
  • Solve a first CFD 2D model using an impeller with 35 blades (upper limit of the usual range) and export the pressure distribution on the blade surface.
  • Create a computer aided design (CAD) model of a single blade, based on the impeller width B and on the previously computed cross-section. Add to the CAD model a small portion of the two disks at the ends of the blade and apply the fillet radius at the blade–disk connection. If the turbine design includes one or more intermediate baffles, a fillet radius will be introduced on the connection baffle too. Use the pressure field on the blade previously computed in point 6.
  • Using an FEM code, compute the stress field and the maximum von Mises stress S.
  • If the maximum thickness used in point 4 does not make it possible to keep the maximum von Mises stress value below a predetermined admissible value, here indicated as Sadm, then a new attempt must be made either with a larger value of the maximum thickness or the introduction of a new reinforcing baffle. Using one or both of the new geometries, compute again the corresponding section and update the number of blades with the optimal one corresponding to the new maximum thickness by iteratively solving a CFD 2D model for each possible number. Update the pressure distribution on the blade surface and go back to point 5. The trial and error procedure must be repeated until the stress level is satisfactory.
  • Perform a final validation of the impeller geometry using only one CFD 3D simulation coupled with FEM analysis.

6. A Case Study: Fontes Episcopi Power Plant

We applied the proposed impeller design in a PRS turbine already installed in a pressure regulation node, named Fontes Episcopi, which is part of a larger water transport network of Sicily (Italy), named Gela-Aragona. The installed PRS turbine was designed with the following input parameters: ΔH = 100 m, Q = 100 L/s, and ω = 1500 rpm, and its performances were reported in a previous work by some of the present authors [8]. Using the same design parameters, a new PRS turbine, called the PRS2 turbine, was designed with the proposed procedure. Assuming λmax= 110°, the impeller diameter D and the width B were found to be to 234 mm and 55 mm, respectively, by using the design methodology described in [7,8,9].
Three different impellers, made of stainless steel, were designed using old blade geometry (impeller 1 and 2) and the new proposed blade geometry (impeller 3). The tensile strength for stainless steel, Sr, was set around 500 MPa, with a corresponding fatigue limit Sl equal to 250 MPa. The application of a reasonable safety factor provided Sadm =250/3 MPa = 83.3 MPa. The external surface of the blades of impeller 1 had a circular profile. The maximum efficiency was attained for φ = β1, corresponding to tmax= 5.12 mm and with a number of blades equal to 34. The value of the efficiency was η = 79.3%, computed by CFD 3D transient analysis. The maximum von Mises stress Smax = 117.76 MPa was not lower than the admissible limit (Sadm).
If the condition φ=β1 is relaxed, it is possible in impeller 2 to increase tmax up to 7 mm for the external circular profile, corresponding to an optimal number of blades equal to 27 (computed by CFD 2D analyses, and not reported here for brevity). In this case, the maximum von Mises stress is less than Sadm, but the efficiency decreases up to η = 78.2%.
The external surface of the blades of impeller 3 had a cubic profile, as computed according to the procedure described in Section 5, with φ = β1, tmax = 7 mm, and nb = 27. The resulting efficiency value was η = 79.2%, and the maximum von Mises stress was lower than the admissible limit (Sadm).
The von Mises stress of a single blade obtained by FEM analysis (Figure 7) was similar to the final one computed with a CFD 3D simulation coupled with a FEM analysis and equal to 45.91 MPa.
In Figure 8, the internal and external surfaces of the most loaded blade with the pressures computed by the final CFD 3D analysis are shown. The hypothesis of assuming constant pressures along the width for the most stressed blade is approximately validated.
Table 2 presents a summary of the results. The PRS with the proposed new impeller 3 had the best efficiency, and the corresponding maximum von Mises stress was below the admissible limit.

7. Conclusions

A new design criterion for Crossflow-type turbines, coupling hydraulic efficiency with mechanical reliability, was proposed and tested in a real case study. The proper use of 2D-CFD models and 3D-FEM structural models makes it possible to limit the computational effort in order to achieve the final design within a reasonable amount of time (a few weeks) via a standard work station with a few dozen processors.
The new methodology is also based on the non-circular profile of the external surface of the blades. Because Crossflow turbines are often selected for their constructive simplicity, this particular shape seems to be in conflict with the previous motivation. On the other hand, the size of Crossflow impellers remains quite small within significant power levels. Growing 3D printing technologies allow inexpensive construction of molds with very complex geometries but limited size, where mechanical components like the whole impeller can easily be obtained by fusion. The cost of the impeller, made with this new technology, turn out to be much smaller than the cost required using standard technologies for blades with a circular profile.

Author Contributions

Conceptualization: M.S. and T.T.; methodology: M.S. and T.T.; validation: C.A. and C.P.; formal analysis: C.A., C.P., and M.H.; investigation: C.P. and M.H.; data curation: C.P. and M.S.; writing—original draft preparation: T.T. and M.S.; writing—review and editing: M.S., C.A., C.P., and M.H.; supervision: T.T. All authors have read and agree to the published version of the manuscript.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Carravetta, A.; Fecarotta, O.; Sinagra, M.; Tucciarelli, T. Cost-Benefit Analysis for Hydropower Production in Water Distribution Networks by a Pump as Turbine. J. Water Resour. Plan. Manag. 2014, 140, 04014002. [Google Scholar] [CrossRef]
  2. Carravetta, A.; Del Giudice, G.; Fecarotta, O.; Ramos, H. PAT Design Strategy for Energy Recovery in Water Distribution Networks by Electrical Regulation. Energies 2013, 6, 411. [Google Scholar] [CrossRef]
  3. Nakamura, Y.; Komatsu, H.; Shiratori, S.; Shima, R.; Saito, S.; Miyagawa, K. Development of High-Efficiency and Low-Cost Shroudless Turbine for Small Hydropower Generation Plant. In Proceedings of the International Conference on Power Engineering, Yokohama, Japan, 19–20 April 2015. [Google Scholar]
  4. Vagnoni, E.; Andolfatto, L.; Richard, S.; Münch-Alligné, C.; Avellan, F. Hydraulic performance evaluation of a micro-turbine with counter rotating runners by experimental investigation and numerical simulation. Renew. Energy 2018, 126, 943–953. [Google Scholar] [CrossRef]
  5. Sinagra, M.; Sammartano, V.; Aricò, C.; Collura, A. Experimental and Numerical Analysis of a Cross-Flow Turbine. J. Hydraul. Eng. 2016, 142, 04015040. [Google Scholar] [CrossRef]
  6. Sammartano, V.; Filianoti, P.; Sinagra, M.; Tucciarelli, T.; Scelba, G.; Morreale, G. Coupled hydraulic and electronic regulation of crossflow turbines in hydraulic plants. J. Hydraul. Eng. 2017, 143, 04016071. [Google Scholar] [CrossRef]
  7. Sinagra, M.; Aricò, C.; Tucciarelli, T.; Morreale, G. Experimental and numerical analysis of a backpressure Banki inline turbine for pressure regulation and energy production. Renew. Energy 2019, 149, 980–986. [Google Scholar] [CrossRef]
  8. Sinagra, M.; Aricò, C.; Tucciarelli, T.; Amato, P.; Fiorino, M. Coupled Electric and Hydraulic Control of a PRS Turbine in a Real Transport Water Network. Water 2019, 11, 1194. [Google Scholar] [CrossRef]
  9. Sinagra, M.; Sammartano, V.; Morreale, G.; Tucciarelli, T. A new device for pressure control and energy recovery in water distribution networks. Water 2017, 9, 309. [Google Scholar] [CrossRef]
  10. Adhikari, R.; Wood, D. The Design of High Efficiency Crossflow Hydro Turbines: A Review and Extension. Energies 2018, 11, 267. [Google Scholar] [CrossRef]
Figure 1. Power recovery system (PRS) turbine.
Figure 1. Power recovery system (PRS) turbine.
Environsciproc 02 00049 g001
Figure 2. Blade internal surface.
Figure 2. Blade internal surface.
Environsciproc 02 00049 g002
Figure 3. Efficiencies for circular outer profile.
Figure 3. Efficiencies for circular outer profile.
Environsciproc 02 00049 g003
Figure 4. (a) Blade with new external profile. (b) Tangent condition of external end.
Figure 4. (a) Blade with new external profile. (b) Tangent condition of external end.
Environsciproc 02 00049 g004
Figure 5. Efficiency of blades with circular and cubic external profiles.
Figure 5. Efficiency of blades with circular and cubic external profiles.
Environsciproc 02 00049 g005
Figure 6. Velocity field in the 3D (left) and 2D (right) simulations.
Figure 6. Velocity field in the 3D (left) and 2D (right) simulations.
Environsciproc 02 00049 g006
Figure 7. Von Mises stress for single blade finite element method (FEM) analysis.
Figure 7. Von Mises stress for single blade finite element method (FEM) analysis.
Environsciproc 02 00049 g007
Figure 8. Pressure computed by CFD 3D transient analysis.
Figure 8. Pressure computed by CFD 3D transient analysis.
Environsciproc 02 00049 g008
Table 1. PRS1 parameters.
Table 1. PRS1 parameters.
PRS1 ParameterValuePRS1 ParameterValue
ΔH (Design head drop)40 mω755 rpm
Q (Design flow rate)210 L/sα15°
D297 mmβ28.2°
B144 mmλmax110°
Table 2. Comparison of impellers.
Table 2. Comparison of impellers.
ImpellerImpeller 1Impeller 2Proposed Impeller 3
External profileCircularCircularCubic
tmax5.12 mm7 mm7 mm
nb342727
η79.3%78.2%79.2%
Smax117.76 MPa47.16 MPa45.14 MPa
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Sinagra, M.; Tucciarelli, T.; Picone, C.; Aricò, C.; Hannachi, M. Design of Reliable and Efficient Banki-Type Turbines. Environ. Sci. Proc. 2020, 2, 49. https://doi.org/10.3390/environsciproc2020002049

AMA Style

Sinagra M, Tucciarelli T, Picone C, Aricò C, Hannachi M. Design of Reliable and Efficient Banki-Type Turbines. Environmental Sciences Proceedings. 2020; 2(1):49. https://doi.org/10.3390/environsciproc2020002049

Chicago/Turabian Style

Sinagra, Marco, Tullio Tucciarelli, Calogero Picone, Costanza Aricò, and Marwa Hannachi. 2020. "Design of Reliable and Efficient Banki-Type Turbines" Environmental Sciences Proceedings 2, no. 1: 49. https://doi.org/10.3390/environsciproc2020002049

APA Style

Sinagra, M., Tucciarelli, T., Picone, C., Aricò, C., & Hannachi, M. (2020). Design of Reliable and Efficient Banki-Type Turbines. Environmental Sciences Proceedings, 2(1), 49. https://doi.org/10.3390/environsciproc2020002049

Article Metrics

Back to TopTop