Next Article in Journal
Molecular Docking Studies of Antimalarial Compounds from the Acetonic Extract of Cecropia obtusifolia 
Previous Article in Journal
Podophyllotoxin Content Analysis of Linum album Kotschy ex Boiss. Subjected to Short-Term Potassium Deficiency Stress
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Sulfur [18F]Fluoride Exchange Reaction Enables Rapid Access to 18F-Labeled PET Tracers †

1
Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiopharmaceutical Cancer Research, 01328 Dresden, Germany
2
Faculty of Chemistry and Food Chemistry, School of Science, TU Dresden, 01069 Dresden, Germany
*
Author to whom correspondence should be addressed.
Presented at the 8th International Electronic Conference on Medicinal Chemistry, 1–30 November 2022; Available online: https://ecmc2022.sciforum.net/.
Med. Sci. Forum 2022, 14(1), 127; https://doi.org/10.3390/ECMC2022-13652
Published: 16 November 2022
(This article belongs to the Proceedings of The 8th International Electronic Conference on Medicinal Chemistry)

Abstract

:
Efficient 18F-fluorination procedures for the production of radiopharmaceuticals are urgently needed to satisfy the increasing demand for clinical diagnostics using positron emission tomography (PET). However, the development of PET tracers is often a time-consuming and challenging process. This work examines the applicability of the recently described sulfur [18F]fluoride exchange ([18F]SuFEx) chemistry as a fast screening approach towards a number of clinically relevant PET tracer preparations. The preparation of a number of 18F-labeled compounds commenced with [18F]fluoride loading onto a quarternary methylammonium (QMA) cartridge, which was eluted with a methanolic solution containing a base, followed by solvent removal under reduced pressure. Thereafter, the radiolabeling precursors in MeCN were added to the reaction vessels, and allowed to react via [18F]SuFEx at room temperature for 5 min. The radiofluorination reactions were quenched by water dilution followed by C18 cartridge purification. The 18F-labeled products were isolated by elution from the cartridge with EtOH and the identities of the products were confirmed by radio-ultra high performance liquid chromatography (UHPLC). The optimized preparations of 18F-labeled prostate-specific membrane antigen (PSMA) inhibitor, Programmed death-ligand 1 (PD-L1) ligand, cyclooxygenase-2 inhibitor (COXIB), and Fibroblast activation protein alpha inhibitor (FAPI) were achieved with high non-decay corrected isolated activity yields (AY) of 33–57% (n = 12) and >95% radiochemical purity (RCP) in 25 min. The automated radiosynthesis procedures afforded the radiolabeled products in an unoptimized 8–15% AY (n = 5), with >95% RCP in 40 min. The ultra-fast [18F]SuFEx reaction permitted several structurally diverse 18F-labeled compounds for potential imaging to be rapidly achieved in excellent isolated AYs and high RCP. Presently, optimization of the automated radiosynthesis and biological assessment of the 18F-labeled products is underway.

Supplementary Materials

The following are available online at https://www.mdpi.com/article/10.3390/ECMC2022-13652/s1.

Author Contributions

Conceptualization, A.C.; methodology, A.C., F.B., M.L., J.K., F.K., C.K.D., and M.U.; resources, K.K. and S.S.; writing—original draft preparation, A.C.; writing—review and editing, M.L., K.K., and S.S.; supervision, S.S.; All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Craig, A.; Kogler, J.; Krutzek, F.; Brandt, F.; Laube, M.; Ullrich, M.; Donat, C.K.; Kopka, K.; Stadlbauer, S. Sulfur [18F]Fluoride Exchange Reaction Enables Rapid Access to 18F-Labeled PET Tracers. Med. Sci. Forum 2022, 14, 127. https://doi.org/10.3390/ECMC2022-13652

AMA Style

Craig A, Kogler J, Krutzek F, Brandt F, Laube M, Ullrich M, Donat CK, Kopka K, Stadlbauer S. Sulfur [18F]Fluoride Exchange Reaction Enables Rapid Access to 18F-Labeled PET Tracers. Medical Sciences Forum. 2022; 14(1):127. https://doi.org/10.3390/ECMC2022-13652

Chicago/Turabian Style

Craig, Austin, Jürgen Kogler, Fabian Krutzek, Florian Brandt, Markus Laube, Martin Ullrich, Cornelius Kurt Donat, Klaus Kopka, and Sven Stadlbauer. 2022. "Sulfur [18F]Fluoride Exchange Reaction Enables Rapid Access to 18F-Labeled PET Tracers" Medical Sciences Forum 14, no. 1: 127. https://doi.org/10.3390/ECMC2022-13652

APA Style

Craig, A., Kogler, J., Krutzek, F., Brandt, F., Laube, M., Ullrich, M., Donat, C. K., Kopka, K., & Stadlbauer, S. (2022). Sulfur [18F]Fluoride Exchange Reaction Enables Rapid Access to 18F-Labeled PET Tracers. Medical Sciences Forum, 14(1), 127. https://doi.org/10.3390/ECMC2022-13652

Article Metrics

Back to TopTop