Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = 1st- and 2nd-order sensitivities to the average number of neutrons per fission

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
49 pages, 715 KB  
Article
Comprehensive Second-Order Adjoint Sensitivity Analysis Methodology (2nd-ASAM) Applied to a Subcritical Experimental Reactor Physics Benchmark: IV. Effects of Imprecisely Known Source Parameters
by Ruixian Fang and Dan Gabriel Cacuci
Energies 2020, 13(6), 1431; https://doi.org/10.3390/en13061431 - 19 Mar 2020
Cited by 15 | Viewed by 2031
Abstract
By applying the Second-Order Adjoint Sensitivity Analysis Methodology (2nd-ASAM) to the polyethylene-reflected plutonium (PERP) benchmark, this work presents results for the first- and second-order sensitivities of this benchmark’s leakage response with respect to the spontaneous fission source parameters. The numerical results obtained for [...] Read more.
By applying the Second-Order Adjoint Sensitivity Analysis Methodology (2nd-ASAM) to the polyethylene-reflected plutonium (PERP) benchmark, this work presents results for the first- and second-order sensitivities of this benchmark’s leakage response with respect to the spontaneous fission source parameters. The numerical results obtained for these sensitivities indicate that the 1st-order relative sensitivity of the leakage response to the source parameters for the two fissionable isotopes in the benchmark are all positive, signifying that an increase in the source parameters will cause an increase in the total neutron leakage from the PERP sphere. The 1st- and 2nd-order relative sensitivities with respect to the source parameters for 239Pu are very small (10−4 or less). In contradistinction, the 1st-order and several 2nd-order relative sensitivities of the leakage response with respect to the source parameters of 240Pu are large. Large values (e.g., greater than 1.0) are also displayed by several mixed 2nd-order relative sensitivities of the leakage response with respect to parameters involving the source and: (i) the total cross sections; (ii) the average neutrons per fission; and (iii) the isotopic number densities. On the other hand, the values of the mixed 2nd-order relative sensitivities with respect to parameters involving the source and: (iv) the scattering cross sections; and (v) and the fission cross sections are smaller than 1.0. It is also shown that the effects of the 1st- and 2nd-order sensitivities of the PERP benchmark’s leakage response with respect to the benchmark’s source parameters on the moments (expected value, variance and skewness) of the PERP benchmark’s leakage response distribution are negligibly smaller than the corresponding effects (on the response distribution) stemming from uncertainties in the total, fission and scattering cross sections. Full article
Show Figures

Figure 1

67 pages, 6720 KB  
Article
Comprehensive Second-Order Adjoint Sensitivity Analysis Methodology (2nd-ASAM) Applied to a Subcritical Experimental Reactor Physics Benchmark: III. Effects of Imprecisely Known Microscopic Fission Cross Sections and Average Number of Neutrons per Fission
by D. G. Cacuci, R. Fang, J. A. Favorite, M. C. Badea and F. Di Rocco
Energies 2019, 12(21), 4100; https://doi.org/10.3390/en12214100 - 27 Oct 2019
Cited by 20 | Viewed by 2693
Abstract
The Second-Order Adjoint Sensitivity Analysis Methodology (2nd-ASAM) is applied to compute the first-order and second-order sensitivities of the leakage response of a polyethylene-reflected plutonium (PERP) experimental system with respect to the following nuclear data: Group-averaged isotopic microscopic fission cross sections, mixed fission/total, fission/scattering [...] Read more.
The Second-Order Adjoint Sensitivity Analysis Methodology (2nd-ASAM) is applied to compute the first-order and second-order sensitivities of the leakage response of a polyethylene-reflected plutonium (PERP) experimental system with respect to the following nuclear data: Group-averaged isotopic microscopic fission cross sections, mixed fission/total, fission/scattering cross sections, average number of neutrons per fission (), mixed /total cross sections, /scattering cross sections, and /fission cross sections. The numerical results obtained indicate that the 1st-order relative sensitivities for these nuclear data are smaller than the 1st-order sensitivities of the PERP leakage response with respect to the total cross sections but are larger than those with respect to the scattering cross sections. The vast majority of the 2nd-order unmixed sensitivities are smaller than the corresponding 1st-order ones, but several 2nd-order mixed relative sensitivities are larger than the 1st-order ones. In particular, several 2nd-order sensitivities for 239Pu are significantly larger than the corresponding 1st-order ones. It is also shown that the effects of the 2nd-order sensitivities of the PERP benchmark’s leakage response with respect to the benchmark’s parameters underlying the average number of neutrons per fission, , on the moments (expected value, variance, and skewness) of the PERP benchmark’s leakage response distribution are negligible by comparison to the corresponding effects (on the response distribution) stemming from uncertainties in the total cross sections, but are larger than the corresponding effects (on the response distribution) stemming from uncertainties in the fission and scattering cross sections. Full article
Show Figures

Figure 1

Back to TopTop