Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = HDP bone SPECT/CT

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
8 pages, 1582 KB  
Communication
SPECT/CT Radiomics for Differentiating between Enchondroma and Grade I Chondrosarcoma
by Hyukjin Yoon, Woo Hee Choi, Min Wook Joo, Seunggyun Ha and Yong-An Chung
Tomography 2023, 9(5), 1868-1875; https://doi.org/10.3390/tomography9050148 - 16 Oct 2023
Cited by 6 | Viewed by 2516
Abstract
This study was performed to assess the value of SPECT/CT radiomics parameters in differentiating enchondroma and atypical cartilaginous tumors (ACTs) located in the long bones. Quantitative HDP SPECT/CT data of 49 patients with enchondromas or ACTs in the long bones were retrospectively reviewed. [...] Read more.
This study was performed to assess the value of SPECT/CT radiomics parameters in differentiating enchondroma and atypical cartilaginous tumors (ACTs) located in the long bones. Quantitative HDP SPECT/CT data of 49 patients with enchondromas or ACTs in the long bones were retrospectively reviewed. Patients were randomly split into training (n = 32) and test (n = 17) data, and SPECT/CT radiomics parameters were extracted. In training data, LASSO was employed for feature reduction. Selected parameters were compared with classic quantitative parameters for the prediction of diagnosis. Significant parameters from training data were again tested in the test data. A total of 12 (37.5%) and 6 (35.2%) patients were diagnosed as ACTs in training and test data, respectively. LASSO regression selected two radiomics features, zone-length non-uniformity for zone (ZLNUGLZLM) and coarseness for neighborhood grey-level difference (CoarsenessNGLDM). Multivariate analysis revealed higher ZLNUGLZLM as the only significant independent factor for the prediction of ACTs, with sensitivity and specificity of 85.0% and 58.3%, respectively, with a cut-off value of 191.26. In test data, higher ZLNUGLZLM was again associated with the diagnosis of ACTs, with sensitivity and specificity of 83.3% and 90.9%, respectively. HDP SPECT/CT radiomics may provide added value for differentiating between enchondromas and ACTs. Full article
(This article belongs to the Special Issue New Advances in Radionuclide Bone Imaging)
Show Figures

Figure 1

14 pages, 7187 KB  
Article
Quantitative Assessment of Treatment Response in Metastatic Breast Cancer Patients by SPECT-CT Bone Imaging—Getting Closer to PET-CT
by Mirela Gherghe, Mario-Demian Mutuleanu, Adina Elena Stanciu, Ionela Irimescu, Alexandra Maria Lazar, Radu Valeriu Toma, Oana Gabriela Trifanescu and Rodica Maricela Anghel
Cancers 2023, 15(3), 696; https://doi.org/10.3390/cancers15030696 - 23 Jan 2023
Cited by 9 | Viewed by 3681
Abstract
Background: Cancer represents the major cause of death mainly through its ability to spread to other organs, highlighting the importance of metastatic disease diagnosis and accurate follow up for treatment management purposes. Although until recently the main method for imaging interpretation was represented [...] Read more.
Background: Cancer represents the major cause of death mainly through its ability to spread to other organs, highlighting the importance of metastatic disease diagnosis and accurate follow up for treatment management purposes. Although until recently the main method for imaging interpretation was represented by qualitative methods, quantitative analysis of SPECT-CT data represents a viable, objective option. Methods: Seventy-five breast cancer patients presenting metastatic bone disease underwent at least two Bone SPECT-CT studies using [99mTc]-HDP between November 2019 to October 2022. Results: Our findings show a good positive relationship between the qualitative methods of imaging interpretation and quantitative analysis, with a correlation coefficient of 0.608 between qualitative whole body scintigraphy and quantitative SPECT-CT, and a correlation coefficient of 0.711 between the qualitative and quantitative interpretation of SPECT-CT data; nevertheless, there is a need for accurate, objective and reproducible methods for imaging interpretation, especially for research purposes. Conclusions: Quantitative evaluation of the SPECT-CT data has the potential to be the first choice of imaging interpretation for patient follow up and treatment response evaluation, especially for research purposes, because of its objectivity and expression of uptake changes in absolute units. Full article
(This article belongs to the Special Issue Invasion and Progression of Solid Tumors in Bone)
Show Figures

Figure 1

22 pages, 3904 KB  
Article
The Role of Nuclear Medicine Imaging with 18F-FDG PET/CT, Combined 111In-WBC/99mTc-Nanocoll, and 99mTc-HDP SPECT/CT in the Evaluation of Patients with Chronic Problems after TKA or THA in a Prospective Study
by Ramune Aleksyniene, Victor Iyer, Henrik Christian Bertelsen, Majbritt Frost Nilsson, Vesal Khalid, Henrik Carl Schønheyder, Lone Heimann Larsen, Poul Torben Nielsen, Andreas Kappel, Trine Rolighed Thomsen, Jan Lorenzen, Iben Ørsted, Ole Simonsen, Peter Lüttge Jordal and Sten Rasmussen
Diagnostics 2022, 12(3), 681; https://doi.org/10.3390/diagnostics12030681 - 10 Mar 2022
Cited by 9 | Viewed by 4410
Abstract
Background: The aim of this prospective study was to assess the diagnostic value of nuclear imaging with 18F-FDG PET/CT (FDG PET/CT), combined 111In-WBC/99mTc-Nanocoll, and 99mTc-HDP SPECT/CT (dual-isotope WBC/bone marrow scan) for patients with chronic problems related to knee [...] Read more.
Background: The aim of this prospective study was to assess the diagnostic value of nuclear imaging with 18F-FDG PET/CT (FDG PET/CT), combined 111In-WBC/99mTc-Nanocoll, and 99mTc-HDP SPECT/CT (dual-isotope WBC/bone marrow scan) for patients with chronic problems related to knee or hip prostheses (TKA or THA) scheduled by a structured multidisciplinary algorithm. Materials and Methods: Fifty-five patients underwent imaging with 99mTc–HDP SPECT/CT (bone scan), dual-isotope WBC/bone marrow scan, and FDG PET/CT. The final diagnosis of prosthetic joint infection (PJI) and/or loosening was based on the intraoperative findings and microbiological culture results and the clinical follow-up. Results: The diagnostic performance of dual-isotope WBC/bone marrow SPECT/CT for PJI showed a sensitivity of 100% (CI 0.74–1.00), a specificity of 97% (CI 0.82–1.00), and an accuracy of 98% (CI 0.88–1.00); for PET/CT, the sensitivity, specificity, and accuracy were 100% (CI 0.74–1.00), 71% (CI 0.56–0.90), and 79% (CI 0.68–0.93), respectively. Conclusions: In a standardized prospectively scheduled patient group, the results showed highly specific performance of combined dual-isotope WBC/bone marrow SPECT/CT in confirming chronic PJI. FDG PET/CT has an appropriate accuracy, but the utility of its use in the clinical diagnostic algorithm of suspected PJI needs further evidence. Full article
(This article belongs to the Collection Hybrid Imaging in Medicine)
Show Figures

Figure 1

14 pages, 4471 KB  
Article
Quantitative Analysis of SPECT-CT Data in Metastatic Breast Cancer Patients—The Clinical Significance
by Mirela Gherghe, Mario-Demian Mutuleanu, Adina Elena Stanciu, Ionela Irimescu, Alexandra Lazar, Xenia Bacinschi and Rodica Maricela Anghel
Cancers 2022, 14(2), 273; https://doi.org/10.3390/cancers14020273 - 6 Jan 2022
Cited by 18 | Viewed by 5159
Abstract
Purpose: To assess the potential added value of the SPECT-CT quantitative analysis in metastatic breast cancer lesions detection and differentiation from degenerative lesions. Methods: This prospective monocentric study was conducted on 70 female patients who underwent SPECT-CT bone scans using 99mTc–HDP that [...] Read more.
Purpose: To assess the potential added value of the SPECT-CT quantitative analysis in metastatic breast cancer lesions detection and differentiation from degenerative lesions. Methods: This prospective monocentric study was conducted on 70 female patients who underwent SPECT-CT bone scans using 99mTc–HDP that identified the presence of metastatic bone lesions and degenerative lesions in each patient. Once the lesions were identified, a quantitative analysis of radiotracer uptake was conducted. The highest one to five SUVmax values for both metastatic and degenerative bone lesions were identified in each patient and the data were then statistically analyzed. Results: The SUVmax value was significantly higher in metastatic bone lesions than in degenerative lesions (p < 0.001). The diagnostic accuracy of SPECT-CT quantitative data analysis revealed a sensitivity of 91.5% and a specificity of 93.3% at a cut-off value of the SUVmax of 16.6 g/mL. Conclusion: Quantitative analysis performed using SPECT-CT data can improve the diagnostic accuracy in differentiating between metastatic bone lesions and degenerative lesions, thus leading to appropriate treatment and better follow-up in metastatic breast cancer patients. Full article
(This article belongs to the Special Issue Bone Metastasis in Breast Cancer)
Show Figures

Figure 1

14 pages, 928 KB  
Article
Multidisciplinary Diagnostic Algorithm for Evaluation of Patients Presenting with a Prosthetic Problem in the Hip or Knee: A Prospective Study
by Vesal Khalid, Henrik Carl Schønheyder, Lone Heimann Larsen, Poul Torben Nielsen, Andreas Kappel, Trine Rolighed Thomsen, Ramune Aleksyniene, Jan Lorenzen, Iben Ørsted, Ole Simonsen, Peter Lüttge Jordal and Sten Rasmussen
Diagnostics 2020, 10(2), 98; https://doi.org/10.3390/diagnostics10020098 - 11 Feb 2020
Cited by 7 | Viewed by 3721
Abstract
The predominant indications for revision surgery after total hip (THA) or knee arthroplasty (TKA) are an aseptic failure (AF) and prosthetic joint infection (PJI). Accurate diagnosis is crucial. Therefore, we evaluated prospectively a multidisciplinary diagnostic algorithm including multi-modal radionucleid imaging (RNI) and extended [...] Read more.
The predominant indications for revision surgery after total hip (THA) or knee arthroplasty (TKA) are an aseptic failure (AF) and prosthetic joint infection (PJI). Accurate diagnosis is crucial. Therefore, we evaluated prospectively a multidisciplinary diagnostic algorithm including multi-modal radionucleid imaging (RNI) and extended microbiological diagnostics. If the surgeon suspected PJI or AF, revision surgery was performed with multiple samples obtained in parallel for special culture procedures and later molecular analyses. Alternatively, if the underlying cause was not evident, RNI was scheduled comprising 99Tc—HDP SPECT/CT, 111In-labeled white blood cells combined with 99Tc-nanocoll bone marrow SPECT/CT, and 18F-FDG PET/CT. A multidisciplinary clinical team made a recommendation on the indication for a diagnostic procedure guided by RNI images or revision surgery. A total of 156 patients with 163 arthroplasties were included. Fifty-five patients underwent RNI. In all, 118 revision surgeries were performed in 112 patients: 71 on the indication of AF and 41 revision of PJI. Thirty-four patients were concluded with chronic pain, and revision surgery refrained. The effective median follow-up period was 13 months. A structured approach offered by the algorithm was useful for the clinician in the evaluation of patients with a failing TKA or THA. Surgical revision was possibly obviated in approximately 20% of patients where an explanation or cause of failure was not found. The algorithm served as an effective tool. Full article
(This article belongs to the Section Diagnostic Microbiology and Infectious Disease)
Show Figures

Figure 1

Back to TopTop