Search Results (4)

Search Parameters:
Keywords = SAVI SCOUT

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 1749 KB  
Systematic Review
Wire-Free Targeted Axillary Dissection: A Pooled Analysis of 1300+ Cases Post-Neoadjuvant Systemic Therapy in Node-Positive Early Breast Cancer
by Jajini Varghese, Neill Patani, Umar Wazir, Shonnelly Novintan, Michael J. Michell, Anmol Malhotra, Kinan Mokbel and Kefah Mokbel
Cancers 2024, 16(12), 2172; https://doi.org/10.3390/cancers16122172 - 7 Jun 2024
Cited by 8 | Viewed by 2550
Abstract
Recent advances in neoadjuvant systemic therapy (NST) have significantly improved pathologic complete response rates in early breast cancer, challenging the role of axillary lymph node dissection in nose-positive patients. Targeted axillary dissection (TAD) integrates marked lymph node biopsy (MLNB) and tracer-guided sentinel lymph [...] Read more.
Recent advances in neoadjuvant systemic therapy (NST) have significantly improved pathologic complete response rates in early breast cancer, challenging the role of axillary lymph node dissection in nose-positive patients. Targeted axillary dissection (TAD) integrates marked lymph node biopsy (MLNB) and tracer-guided sentinel lymph node biopsy (SLNB). The introduction of new wire-free localisation markers (LMs) has streamlined TAD and increased its adoption. The primary endpoints include the successful localisation and retrieval rates of LMs. The secondary endpoints include the pathological complete response (pCR), SLNB, and MLNB concordance, as well as false-negative rates. Seventeen studies encompassing 1358 TAD procedures in 1355 met the inclusion criteria. The localisation and retrieval rate of LMs were 97% and 99%. A concordance rate of 67% (95% CI: 64–70) between SLNB and MLNB was demonstrated. Notably, 49 days (range: 0–272) was the average LM deployment time to surgery. pCR was observed in 46% (95% CI: 43–49) of cases, with no significant procedure-related complications. Omitting MLNB or SLNB would have under-staged the axilla in 15.2% or 5.4% (p = 0.0001) of cases, respectively. MLNB inclusion in axillary staging post-NST for initially node-positive patients is crucial. The radiation-free Savi Scout, with its minimal MRI artefacts, is the preferred technology for TAD. Full article
(This article belongs to the Special Issue Neo-Adjuvant Treatment of Breast Cancer)
Show Figures

Figure 1

14 pages, 3009 KB  
Systematic Review
Evaluating Radar Reflector Localisation in Targeted Axillary Dissection in Patients Undergoing Neoadjuvant Systemic Therapy for Node-Positive Early Breast Cancer: A Systematic Review and Pooled Analysis
by Umar Wazir, Michael J. Michell, Munaser Alamoodi and Kefah Mokbel
Cancers 2024, 16(7), 1345; https://doi.org/10.3390/cancers16071345 - 29 Mar 2024
Cited by 9 | Viewed by 2986
Abstract
SAVI SCOUT® or radar reflector localisation (RRL) has proven accurate in localising non-palpable breast and axillary lesions, with minimal interference with MRI. Targeted axillary dissection (TAD), combining marked lymph node biopsy (MLNB) and sentinel lymph node biopsy (SLNB), is becoming a standard [...] Read more.
SAVI SCOUT® or radar reflector localisation (RRL) has proven accurate in localising non-palpable breast and axillary lesions, with minimal interference with MRI. Targeted axillary dissection (TAD), combining marked lymph node biopsy (MLNB) and sentinel lymph node biopsy (SLNB), is becoming a standard post-neoadjuvant systemic therapy (NST) for node-positive early breast cancer. Compared to SLNB alone, TAD reduces the false negative rate (FNR) to below 6%, enabling safer axillary surgery de-escalation. This systematic review evaluates RRL’s performance during TAD, assessing localisation and retrieval rates, the concordance between MLNB and SLNB, and the pathological complete response (pCR) in clinically node-positive patients post-NST. Four studies (252 TAD procedures) met the inclusion criteria, with a 99.6% (95% confidence [CI]: 98.9–100) successful localisation rate, 100% retrieval rate, and 81% (95% CI: 76–86) concordance rate between SLNB and MLNB. The average duration from RRL deployment to surgery was 52 days (range:1–202). pCR was observed in 42% (95% CI: 36–48) of cases, with no significant migration or complications reported. Omitting MLNB or SLNB would have under-staged the axilla in 9.7% or 3.4% (p = 0.03) of cases, respectively, underscoring the importance of incorporating MLNB in axillary staging post-NST in initially node-positive patients in line with the updated National Comprehensive Cancer Network (NCCN) guidelines. These findings underscore the excellent efficacy of RRL in TAD for NST-treated patients with positive nodes, aiding in accurate axillary pCR identification and the safe omission of axillary dissection in strong responders. Full article
(This article belongs to the Section Systematic Review or Meta-Analysis in Cancer Research)
Show Figures

Figure 1

19 pages, 1016 KB  
Review
Comparison of Wire and Non-Wire Localisation Techniques in Breast Cancer Surgery: A Review of the Literature with Pooled Analysis
by Shahram Shirazi, Hamed Hajiesmaeili, Muskaan Khosla, Saima Taj, Tapan Sircar and Raghavan Vidya
Medicina 2023, 59(7), 1297; https://doi.org/10.3390/medicina59071297 - 13 Jul 2023
Cited by 19 | Viewed by 4435
Abstract
Background and Objectives: Wide local excision is a common procedure in the treatment of breast cancer. Wire-guided localisation (WGL) has been the gold standard for many years; however, several issues have been identified with this technique, and therefore, wire-free techniques have been developed. [...] Read more.
Background and Objectives: Wide local excision is a common procedure in the treatment of breast cancer. Wire-guided localisation (WGL) has been the gold standard for many years; however, several issues have been identified with this technique, and therefore, wire-free techniques have been developed. This scoping review synthesises the available literature comparing wire-guided localisation with the wire-free techniques used in breast-conserving cancer surgery. Materials and Methods: Multiple databases including Pubmed and MEDLINE were used to search articles between 1 January 2000 and 31 December 2022. Terms included “breast neoplasms”, “margins of excision”, and “reoperation”. In total, 34/256 papers were selected for review. Comparisons were made between positive margins and re-excision rates of WGL with wire-free techniques including SAVI SCOUT, Magseed, ROLL, and RSL. Pooled p-values were calculated using chi-square testing to determine statistical significance. Results: Pooled analysis demonstrated statistically significant reductions in positive margins and re-excision rates when SAVI SCOUT, RSL, and ROLL were compared with WGL. When SAVI SCOUT was compared to WGL, there were fewer re-excisions {(8.6% vs. 18.8%; p = 0.0001) and positive margins (10.6% vs. 15.0%; p = 0.0105)}, respectively. This was also the case in the ROLL and RSL groups. When compared to WGL; lower re-excision rates and positive margins were noted {(12.6% vs. 20.8%; p = 0.0007), (17.0% vs. 22.9%; p = 0.0268)} for ROLL and for RSL, respectively {(6.8% vs. 14.9%),(12.36% vs. 21.4%) (p = 0.0001)}. Magseed localisation demonstrated lower rates of re-excision than WGL (13.44% vs. 15.42%; p = 0.0534), but the results were not statistically significant. Conclusions: SAVI SCOUT, Magseed, ROLL, and RSL techniques were reviewed. Pooled analysis indicates wire-free techniques, specifically SAVI SCOUT, ROLL, and RSL, provide statistically significant reductions in re-excision rates and positive margin rates compared to WGL. However, additional studies and systematic analysis are required to ascertain superiority between techniques. Full article
(This article belongs to the Special Issue Challenges and Innovations in Breast Cancer Surgery)
Show Figures

Figure 1

15 pages, 4543 KB  
Article
Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT® System
by Umar Wazir, Iham Kasem, Michael J. Michell, Tamara Suaris, David Evans, Anmol Malhotra and Kefah Mokbel
Cancers 2021, 13(10), 2409; https://doi.org/10.3390/cancers13102409 - 17 May 2021
Cited by 22 | Viewed by 6359
Abstract
Wire-guided localisation (WGL) has been the mainstay for localising non-palpable breast lesions before excision. Due to its limitations, various wireless alternatives have been developed. In this prospective study, we evaluate the role of radiation-free wireless localisation using the SAVI SCOUT® system at [...] Read more.
Wire-guided localisation (WGL) has been the mainstay for localising non-palpable breast lesions before excision. Due to its limitations, various wireless alternatives have been developed. In this prospective study, we evaluate the role of radiation-free wireless localisation using the SAVI SCOUT® system at the London Breast Institute. A total of 72 reflectors were deployed in 67 consecutive patients undergoing breast conserving surgery for non-palpable breast lesions. The mean interval between deployment and surgery for the therapeutic cases was 18.8 days (range: 0–210). The median deployment duration was 5 min (range: 1–15 min). The mean distance from the lesion was 1.1 mm (median distance: 0; range: 0–20 mm). The rate of surgical localisation and retrieval of the reflector was 98.6% and 100%, respectively. The median operating time was 28 min (range: 15–55 min) for the therapeutic excision of malignancy and 17 min (range: 15–24) for diagnostic excision. The incidence of reflector migration was 0%. Radial margin positivity in malignant cases was 7%. The median weight for malignant lesions was 19.6 g (range: 3.5–70 g). Radiologists and surgeons rated the system higher than WGL (93.7% and 98.6%, respectively; 60/64 and 70/71). The patient mean satisfaction score was 9.7/10 (n = 47, median = 10; range: 7–10). One instance of signal failure was reported. In patients who had breast MRI after the deployment of the reflector, the MRI void signal was <5 mm (n = 6). There was no specific technique-related surgical complication. Our study demonstrates that wire-free localisation using SAVI SCOUT® is an effective and time-efficient alternative to WGL with excellent physician and patient acceptance. Full article
Show Figures

Figure 1

Back to TopTop