Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = draped strands

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 2136 KB  
Article
Experimental Study on Shear Failure of 30 m Pre-Tensioned Concrete T-Beams Under Small Shear Span Ratio
by Qianyi Zhang, Hai Yan, Chunlei Zhang, Ding-Hao Yu, Jiaolei Zhang, Gang Li, Mingguang Wei, Jinglin Tao and Huiteng Pei
Buildings 2025, 15(11), 1946; https://doi.org/10.3390/buildings15111946 - 4 Jun 2025
Viewed by 448
Abstract
Pre-tensioned concrete T-beams with draped strands have been gradually promoted and used in bridge construction in recent years due to their advantages such as simple structure, efficient force distribution, and few defects. However, the current design codes exhibit conservative provisions for the calculation [...] Read more.
Pre-tensioned concrete T-beams with draped strands have been gradually promoted and used in bridge construction in recent years due to their advantages such as simple structure, efficient force distribution, and few defects. However, the current design codes exhibit conservative provisions for the calculation of the shear capacity of such beams under a small shear span ratio, which may lead to a large design value of beam web thickness. This is primarily due to insufficient experimental data. This paper details a full-scale experimental investigation on the shear failure mechanisms of two 30 m pre-tensioned concrete T-beams with draped strands, under a shear span ratio of 1, at which the shear capacity of the beams represents their upper limit. The specimens were tested to analyze their mechanical behavior, including load-deflection response, crack distribution, stirrup strain, and strand slip. The ultimate shear capacities of the test beams were 7107 kN and 6742 kN. To evaluate the applicability of current design codes, the experimental results were compared with theoretical predictions from five international design codes. The analysis revealed that the AASHTO code provided the highest upper limit of shear capacity for pre-tensioned concrete T-beams with draped strands, whereas the Chinese code (JTG 3362-2018) exhibited a significantly high safety factor of 4.09. These findings provide a basis for the optimized design of pre-tensioned concrete T-beams with draped strands and the determination of the upper limit of shear capacity. Full article
(This article belongs to the Special Issue Structural Vibration Analysis and Control in Civil Engineering)
Show Figures

Figure 1

Back to TopTop