Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = eccentric silo

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
21 pages, 5767 KiB  
Article
Research on the Spatial Torsional Effect of Column-Supported Structural Silo Groups Based on Shaking Table Tests
by Huifen Wang, Yonggang Ding, Xuesen Li, Guoqi Ren, Zhiyao Zhou and Qikeng Xu
Buildings 2025, 15(11), 1851; https://doi.org/10.3390/buildings15111851 - 28 May 2025
Viewed by 33
Abstract
Food security is a critical component of national security. Grain silos, as key infrastructure for food storage, must remain structurally resilient under seismic actions to ensure the stability of grain reserves. However, column-supported vertical-group silo structures are prone to spatial torsional effects during [...] Read more.
Food security is a critical component of national security. Grain silos, as key infrastructure for food storage, must remain structurally resilient under seismic actions to ensure the stability of grain reserves. However, column-supported vertical-group silo structures are prone to spatial torsional effects during earthquakes due to eccentricities between the mass center and the stiffness center after grain loading, which can lead to serious structural damage or collapse. Based on this background, shaking table tests were conducted on a column-supported vertical-group silo structure as the research subject, with a scale ratio of 1/25 and in the 1 row × 3 column combination form. The dynamic response and spatial torsional effect of the structure under different grain storage conditions and seismic intensity effects were studied. To thoroughly analyze the factors influencing the spatial torsion in the structure, finite element–discrete element numerical analysis models of the structure were established based on experiments in Abaqus (6.14) software. The results indicate that in the column-supported vertical-group silo structure, the mass center of the group silo structure deviates from its center of rigidity after grain storage, resulting in significant and irregular spatial torsional effects under earthquake motion. The torsional displacement ratio and inter-story horizontal torsional angle of the structure gradually increased with an increase in the seismic intensity, reaching maximum values of 1.34 and 0.035 rad, respectively, when the peak acceleration input on the table was 0.4 g and under the full–full–empty storage condition. The effects of the void distribution, mass void ratio, and combination form of the group silo structure on the spatial torsional effect of the structure were studied to provide a scientific reference for the seismic design of column-supported silo structures for grain storage. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

16 pages, 5727 KiB  
Article
Numerical Analysis of Influence Mechanism of Orifice Eccentricity on Silo Discharge Rate
by Yinglong Wang, Yanlong Han, Anqi Li, Hao Li, Haonan Gao, Ze Sun, Shouyu Ji, Zhuozhuang Li and Fuguo Jia
Agriculture 2025, 15(5), 490; https://doi.org/10.3390/agriculture15050490 - 25 Feb 2025
Viewed by 398
Abstract
Eccentric silo is an extremely common type of silo, but it is still unclear how to accurately control the discharge by adjusting eccentric orifices, limiting the application and development of eccentric silo. In this study, the rice particle discharging process on silos with [...] Read more.
Eccentric silo is an extremely common type of silo, but it is still unclear how to accurately control the discharge by adjusting eccentric orifices, limiting the application and development of eccentric silo. In this study, the rice particle discharging process on silos with different eccentricities was simulated by the discrete element method (DEM), and the influence mechanism of orifice eccentricity on silo discharge rate was analyzed. The results show that eccentricity has a direct influence on the particle volume fraction and vertical velocity that determine the discharge rate of the silo. In fully eccentric silo, it is not easy for particle flow to achieve balance, particles will pass through outlet with more kinetic energy. Moreover, continuous force network cannot be formed between particles with shear resistance, resulting in weak interlocking action between particles. The orientation of particle in fully eccentric silo is more vertical, especially near the silo wall, which will produce larger local particle volume fraction above the orifice. When the eccentricity exceeds the critical eccentricity, the sparse flow area on the discharge orifice becomes larger, and the particle acceleration area increases accordingly. Research findings may offer valuable insights for the accurate control of discharge rate of eccentric silo, as well as for optimizing silo design. Full article
Show Figures

Figure 1

Back to TopTop