Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (166)

Search Parameters:
Keywords = fire extinguishing system

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 2057 KB  
Article
Numerical Simulation on Effect of Pulsed Water Mist on Temperature and Thermal Radiation in Long and Narrow Underground Space During Fire
by Yanli Deng, Beifang Gu, Ruiqing Zhang, Lielie Li and Lihua Niu
Fire 2025, 8(9), 350; https://doi.org/10.3390/fire8090350 - 3 Sep 2025
Abstract
This study numerically investigated how varying pulse durations of water mist systems influence fire dynamics in long, narrow underground enclosures. A Fire Dynamics Simulator (FDS) model was built to represent a pulse-actuated, fine water mist test rig, and simulations of oil pan fires [...] Read more.
This study numerically investigated how varying pulse durations of water mist systems influence fire dynamics in long, narrow underground enclosures. A Fire Dynamics Simulator (FDS) model was built to represent a pulse-actuated, fine water mist test rig, and simulations of oil pan fires were performed to quantify the evolution of temperature and radiative heat flux. Results show that an 8 s spray followed by an 8 s pause yields the most effective suppression cycle. When spray and pause durations are equal, periodic momentum exchange resonates with the buoyant plume, intensifying the mixing of gas and enhancing cooling near the fire seat. Compared with continuous discharge, pulsed mist generates stronger buoyancy-driven disturbances and delivers superior performance in terms of local heat’s extraction and extinguishment. This study has, for the first time, determined the optimal pulse cycle (8 s spray/8 s stop) for oil pool fires in narrow and long underground spaces through FDS simulation, and revealed the enhancement effect of the gas disturbance resonance mechanism on fire suppression efficiency. Full article
Show Figures

Figure 1

24 pages, 2927 KB  
Article
Modeling of Multifunctional Gas-Analytical Mine Control Systems and Automatic Fire Extinguishing Systems
by Elena Ovchinnikova, Yuriy Kozhubaev, Zhiwei Wu, Aref Sabbaghan and Roman Ershov
Symmetry 2025, 17(9), 1432; https://doi.org/10.3390/sym17091432 - 2 Sep 2025
Abstract
With the development of the mining industry, safety issues in underground operations are becoming increasingly relevant. Complex gas conditions in mines, including the presence of explosive and toxic gases, pose a serious threat to the lives of miners and the stability of production [...] Read more.
With the development of the mining industry, safety issues in underground operations are becoming increasingly relevant. Complex gas conditions in mines, including the presence of explosive and toxic gases, pose a serious threat to the lives of miners and the stability of production processes. This paper describes the development and modeling of an integrated fire monitoring and automatic extinguishing system that combines gas collection, concentration analysis, and rapid response to emergencies. The main components of the system include the following: a gas collection module that uses an array of highly sensitive sensors to continuously measure the concentrations of methane (CH4), carbon monoxide (CO), and hydrogen sulfide (H2S) with an accuracy of up to 95%; a gas analysis module that uses data processing algorithms to identify gas concentration threshold exceedances (e.g., CH4 > 5% vol. or CO > 20 ppm); and an automatic fire extinguishing module that activates nitrogen supply, ventilation, and aerosol/powder fire extinguishers when a threat is detected. Simulation results in MATLAB/Simulink showed that the system reduces the concentration of hazardous gases by 30% within the first 2 s after activation, which significantly increases safety. Additionally, scenarios with various types of fires were analyzed, confirming the effectiveness of the extinguishing modules in mines up to 500 m deep. The integrated system achieves 95% gas detection accuracy, 90 ms response latency, and 40% hazard reduction within 3 s of activation, verified in 500 m deep mine simulations. Quantitative comparison shows a 75% faster response time and 10% higher detection accuracy than conventional systems. The proposed system demonstrates high reliability in difficult conditions, reducing the risk of fires by 75% compared to traditional methods. This work opens up prospects for practical application in the coal industry, especially in regions with a high risk of spontaneous coal combustion, such as India and Germany. Full article
(This article belongs to the Special Issue Symmetry in Reliability Engineering)
Show Figures

Figure 1

19 pages, 3958 KB  
Article
Thermal Runaway Suppression Mechanism of Thermosensitive Microcapsules for Lithium-Ion Batteries
by Zujin Bai, Pei Zhang, Furu Kang, Zeyang Song and Yang Xiao
Polymers 2025, 17(17), 2374; https://doi.org/10.3390/polym17172374 - 31 Aug 2025
Viewed by 153
Abstract
Lithium-ion batteries (LIBs) have garnered extensive application across various domains. However, frequent safety incidents associated with these LIBs have emerged as a significant impediment to their further advancement. Consequently, there is an urgent necessity to develop a novel fire extinguishing agent that possesses [...] Read more.
Lithium-ion batteries (LIBs) have garnered extensive application across various domains. However, frequent safety incidents associated with these LIBs have emerged as a significant impediment to their further advancement. Consequently, there is an urgent necessity to develop a novel fire extinguishing agent that possesses both rapid fire suppression and efficient cooling capabilities, thereby effectively mitigating the occurrence and propagation of fires in LIBs. This study pioneers the development of an adaptive thermosensitive microcapsule (TM) fire extinguishing agent synthesized via in situ polymerization. The TM encapsulates a ternary composite core—perfluorohexanone (C6F12O), heptafluorocyclopentane (C5H3F7), and 2-bromo-3,3,3-trifluoropropene (2-BTP)—within a melamine–urea–formaldehyde (MUF) resin shell. The TM was prepared via in situ polymerization, combined with FE-SEM, FTIR, TG–DSC, and laser particle size analysis to verify that the TM had a uniform particle size and complete coating structure. The results demonstrate that the TM can effectively suppress the thermal runaway (TR) of LIBs through the synergistic effects of physical cooling, chemical suppression, and gas isolation. Specifically, the peak TR temperature of a single-cell LIB is reduced by 14.0 °C, and the heating rate is decreased by 0.17 °C/s. Additionally, TM successfully blocked the propagation of TR thereby preventing its spread in the dual-LIB module test. Limitations of single-component agents are overcome by this innovative system by leveraging the ternary core’s complementary functionalities, enabling autonomous TR suppression without external systems. Furthermore, the TM design integrates precise thermal responsiveness, environmental friendliness, and cost-effectiveness, offering a transformative safety solution for next-generation LIBs. Full article
(This article belongs to the Section Polymer Applications)
Show Figures

Figure 1

13 pages, 2834 KB  
Article
Simulation-Based Investigation of the Effectiveness of Fire Suppression Techniques for Residential Furnishing
by Wenqi Song, Qing He, Qingyu Tan and Guorui Zhu
Fire 2025, 8(8), 327; https://doi.org/10.3390/fire8080327 - 15 Aug 2025
Viewed by 590
Abstract
This study proposes an equivalent furniture fire model based on standard combustible assembly and verifies its feasibility as a substitute for real furniture through full-scale experiments and numerical simulations. Experiments show that the peak heat release rate and total heat release of the [...] Read more.
This study proposes an equivalent furniture fire model based on standard combustible assembly and verifies its feasibility as a substitute for real furniture through full-scale experiments and numerical simulations. Experiments show that the peak heat release rate and total heat release of the standard combustible assembly are highly consistent with those of the single-seat sofa. The numerical model has been verified by experimental data. The dynamic characteristics of the heat release rate (HRR) curve are consistent with the temperature evolution process, confirming its reliability for the numerical model. The research on optimizing fire extinguishing parameters is carried out based on this numerical simulation. The results show that the response time of the horizontal sprinkler is 22 s shorter than that of the vertical sprinkler, and the fire extinguishing efficiency is improved. Reducing the sprinkler height to 3 m can accelerate activation and reduce CO2 release. A flow rate of 91.4 L/min can effectively control the fire, but when it exceeds 150 L/min, the fire extinguishing efficiency is significantly reduced. The low response time index sprinkler starts up 88 s faster than the standard type, significantly enhancing the initial fire suppression capability. This scheme provides a safe, economical, and repeatable standardized combustible assembly for fire training and offers theoretical support for the parameter design of intelligent fire extinguishing systems. Full article
(This article belongs to the Special Issue Advances in Industrial Fire and Urban Fire Research: 2nd Edition)
Show Figures

Figure 1

21 pages, 9894 KB  
Article
Full-Scale Experimental Investigation on the Thermal Control of a Water Mist System in a Road Tunnel Under Single-Source and Double-Source Fire Scenarios
by Deyuan Kan and Shouzhong Feng
Fire 2025, 8(8), 317; https://doi.org/10.3390/fire8080317 - 11 Aug 2025
Viewed by 536
Abstract
This study investigates the thermal control effect of a water mist fire-extinguishing system in road tunnels under both single-source and double-source fire scenarios. A total of eight full-scale fire tests were executed in a physical tunnel, and the double-source fire scenarios were further [...] Read more.
This study investigates the thermal control effect of a water mist fire-extinguishing system in road tunnels under both single-source and double-source fire scenarios. A total of eight full-scale fire tests were executed in a physical tunnel, and the double-source fire scenarios were further subdivided into two spatial configurations, including fire sources close together and fire sources with a center-to-center distance of 2 m. During the fire tests, the evolution of fire, temporal and spatial temperature distributions of the tunnel ceiling, longitudinal and vertical temperature gradients, and smoke behavior within the tunnel were systematically recorded and interpreted. The results demonstrate that early activation of the water mist system optimizes its physicochemical mechanisms by preventing the transition from the growth phase of fire to a stable phase. In single-source fire scenarios, the water mist directly suppresses the flame and eliminates the high-temperature core, leading to a significant alteration in the vertical temperature gradient. For double-source fire scenarios, the high-temperature region on the ceiling is reduced upon the application of the water mist. However, when the fire sources are positioned in close proximity, they tend to merge into a larger fire source, with the water mist proving insufficient to prevent this fusion. Conversely, when the center-to-center distance between the fire sources is 2 m, the water mist effectively separates the sources, blocking thermal feedback between them and forcing the flames to develop vertically. This, in turn, accelerates the attenuation of the fire and the recovery of the ambient temperature. Additionally, within the effective coverage of the water mist, the longitudinal temperature distribution on the tunnel ceiling still follows an exponential attenuation pattern, with a significantly high rate of temperature decline. Full article
Show Figures

Figure 1

36 pages, 13501 KB  
Review
Research Progress on Risk Prevention and Control Technology for Lithium-Ion Battery Energy Storage Power Stations: A Review
by Weihang Pan
Batteries 2025, 11(8), 301; https://doi.org/10.3390/batteries11080301 - 6 Aug 2025
Viewed by 722
Abstract
Amidst the background of accelerated global energy transition, the safety risk of lithium-ion battery energy storage systems, especially the fire hazard, has become a key bottleneck hindering their large-scale application, and there is an urgent need to build a systematic prevention and control [...] Read more.
Amidst the background of accelerated global energy transition, the safety risk of lithium-ion battery energy storage systems, especially the fire hazard, has become a key bottleneck hindering their large-scale application, and there is an urgent need to build a systematic prevention and control program. This paper focuses on the fire characteristics and thermal runaway mechanism of lithium-ion battery energy storage power stations, analyzing the current situation of their risk prevention and control technology across the dimensions of monitoring and early warning technology, thermal management technology, and fire protection technology, and comparing and analyzing the characteristics of each technology from multiple angles. Building on this analysis, this paper summarizes the limitations of the existing technologies and puts forward prospective development paths, including the development of multi-parameter coupled monitoring and warning technology, integrated and intelligent thermal management technology, clean and efficient extinguishing agents, and dynamic fire suppression strategies, aiming to provide solid theoretical support and technical guidance for the precise risk prevention and control of lithium-ion battery storage power stations. Full article
(This article belongs to the Special Issue Advanced Battery Safety Technologies: From Materials to Systems)
Show Figures

Graphical abstract

32 pages, 2698 KB  
Article
Design and Validation of an Edge-AI Fire Safety System with SmartThings Integration for Accelerated Detection and Targeted Suppression
by Seung-Jun Lee, Hong-Sik Yun, Yang-Bae Sim and Sang-Hoon Lee
Appl. Sci. 2025, 15(14), 8118; https://doi.org/10.3390/app15148118 - 21 Jul 2025
Viewed by 1106
Abstract
This study presents the design and validation of an integrated fire safety system that leverages edge AI, hybrid sensing, and precision suppression to overcome the latency and collateral limitations of conventional smoke detection and sprinkler systems. The proposed platform features a dual-mode sensor [...] Read more.
This study presents the design and validation of an integrated fire safety system that leverages edge AI, hybrid sensing, and precision suppression to overcome the latency and collateral limitations of conventional smoke detection and sprinkler systems. The proposed platform features a dual-mode sensor array for early fire recognition, motorized ventilation units for rapid smoke extraction, and a 360° directional nozzle for targeted agent discharge using a residue-free clean extinguishing agent. Experimental trials demonstrated an average fire detection time of 5.8 s and complete flame suppression within 13.2 s, with 90% smoke clearance achieved in under 95 s. No false positives were recorded during non-fire simulations, and the system remained fully functional under simulated cloud communication failure, confirming its edge-resilient architecture. A probabilistic risk analysis based on ISO 31000 and NFPA 551 frameworks showed risk reductions of 75.6% in life safety, 58.0% in property damage, and 67.1% in business disruption. The system achieved a composite risk reduction of approximately 73%, shifting the operational risk level into the ALARP region. These findings demonstrate the system’s capacity to provide proactive, energy-efficient, and spatially targeted fire response suitable for high-value infrastructure. The modular design and SmartThings Edge integration further support scalable deployment and real-time system intelligence, establishing a strong foundation for future adaptive fire protection frameworks. Full article
Show Figures

Figure 1

30 pages, 4865 KB  
Article
Thermal Behavior and Smoke Suppression of Polyamide 6,6 Fabric Treated with ALD-ZnO and DOPO-Based Silane
by Wael Ali, Raphael Otto, Ana Raquel Lema Jimenez, Sebastian Lehmann, Eui-Young Shin, Ying Feng, Milijana Jovic, Sabyasachi Gaan, Jochen S. Gutmann, Kornelius Nielsch, Amin Bahrami and Thomas Mayer-Gall
Materials 2025, 18(13), 3195; https://doi.org/10.3390/ma18133195 - 7 Jul 2025
Viewed by 851
Abstract
Polyamide 6,6 (PA6,6) fabrics are widely used in textiles due to their high mechanical strength and chemical stability. However, their inherent flammability and melting behavior under fire pose significant safety challenges. In this study, a dual-layer flame-retardant system was developed by integrating atomic [...] Read more.
Polyamide 6,6 (PA6,6) fabrics are widely used in textiles due to their high mechanical strength and chemical stability. However, their inherent flammability and melting behavior under fire pose significant safety challenges. In this study, a dual-layer flame-retardant system was developed by integrating atomic layer deposition (ALD) of ZnO with a phosphorus–silane-based flame retardant (DOPO-ETES). ALD allowed precise control of ZnO layer thickness (50, 84, and 199 nm), ensuring uniform coating. Thermal analysis (TGA) and microscale combustion calorimetry (MCC) revealed that ZnO altered the degradation pathway of PA6,6 through catalytic effects, promoting char formation and reducing heat release. The combination of ZnO and DOPO-ETES resulted in further reductions in heat release rates. However, direct flame tests showed that self-extinguishing behavior was not achieved, emphasizing the limitations related to the melting of PA6,6. TG-IR and cone calorimetry confirmed that ZnO coatings suppressed the release of smoke-related volatiles and incomplete combustion products. These findings highlight the potential of combining metal-based catalytic flame retardants like ZnO with phosphorus-based coatings to improve flame retardancy while addressing the specific challenges of polyamide textiles. This approach may also be adapted to other fabric types and integrated with additional flame retardants, broadening its relevance for textile applications. Full article
Show Figures

Graphical abstract

11 pages, 2324 KB  
Proceeding Paper
Development of Autonomous Unmanned Aerial Vehicle for Environmental Protection Using YOLO V3
by Vijayaraja Loganathan, Dhanasekar Ravikumar, Maniyas Philominal Manibha, Rupa Kesavan, Gokul Raj Kusala Kumar and Sarath Sasikumar
Eng. Proc. 2025, 87(1), 72; https://doi.org/10.3390/engproc2025087072 - 6 Jun 2025
Viewed by 469
Abstract
Unmanned aerial vehicles, also termed as unarmed aerial vehicles, are used for various purposes in and around the environment, such as delivering things, spying on opponents, identification of aerial images, extinguishing fire, spraying the agricultural fields, etc. As there are multi-functions in a [...] Read more.
Unmanned aerial vehicles, also termed as unarmed aerial vehicles, are used for various purposes in and around the environment, such as delivering things, spying on opponents, identification of aerial images, extinguishing fire, spraying the agricultural fields, etc. As there are multi-functions in a single UAV model, it can be used for various purposes as per the user’s requirement. The UAVs are used for faster communication of identified information, entry through the critical atmospheres, and causing no harm to humans before entering a collapsed path. In relation to the above discussion, a UAV system is designed to classify and transmit information about the atmospheric conditions of the environment to a central controller. The UAV is equipped with advanced sensors that are capable of detecting air pollutants such as carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), ammonia (NH3), hydrogen sulfide (H2S), etc. These sensors present in the UAV model monitor the quality of air, time-to-time, as the UAV navigates through different areas and transmits real-time data regarding the air quality to a central unit; this data includes detailed information on the concentrations of different pollutants. The central unit analyzes the data that are captured by the sensor and checks whether the quality of air meets the atmospheric standards. If the sensed levels of pollutants exceed the thresholds, then the system present in the UAV triggers a warning alert; this alert is communicated to local authorities and the public to take necessary precautions. The developed UAV is furnished with cameras which are used to capture real-time images of the environment and it is processed using the YOLO V3 algorithm. Here, the YOLO V3 algorithm is defined to identify the context and source of pollution, such as identifying industrial activities, traffic congestion, or natural sources like wildfires. Full article
(This article belongs to the Proceedings of The 5th International Electronic Conference on Applied Sciences)
Show Figures

Figure 1

22 pages, 6584 KB  
Article
Fire Test Study and FDS Verification of Spray Water Volume for Small-Sized Bookstores in the Revitalization of Historical Buildings
by Peng Du, Jing Liu, Cheng Zhang, Zhixin Zheng, Guangyue Gu, Jiaming Zhao, Feng Yan, Songtao Liu, Rutian Li and Jun Zhang
Fire 2025, 8(6), 224; https://doi.org/10.3390/fire8060224 - 3 Jun 2025
Viewed by 1194
Abstract
Small bookstores constructed before the 1970s have a high fire risk in the context of the revitalization of historical buildings; while the setup of simple sprinklers is an effective and cheap method of extinguishing fires, the parameters of the sprinklers are uncertain. In [...] Read more.
Small bookstores constructed before the 1970s have a high fire risk in the context of the revitalization of historical buildings; while the setup of simple sprinklers is an effective and cheap method of extinguishing fires, the parameters of the sprinklers are uncertain. In this study, small bookstores in Beijing were selected, and physical combustion experiments with/without a sprinkler system were carried out following the provisions of the Code for the Design of Sprinkler Systems. After the experiments, an FDS model was set up using fire dynamics software. The results show that the total heat release rate (HRR) of books and desks is related to the square of time, with a coefficient of 2.528 × 10−6, and the maximum heat release rate is 40 KW. Unlike the standard test, the physical combustion experiment is significantly affected by the space. According to numerical simulations, when the sprinkler flow velocity is 60~100 L/min, the water consumption of the sprinkler is 195~218 L. This study lays the foundation for the analysis of the combustion characteristics of small bookstores and provides data support for the installation of simple sprinkler systems in small bookstores. Full article
(This article belongs to the Special Issue Confined Space Fire Safety and Alternative Fuel Fire Safety)
Show Figures

Figure 1

25 pages, 10258 KB  
Article
Full-Scale Experimental Investigation of Temperature Distribution and Smoke Flow in a Road Tunnel with a Novel Water Mist Fire Fighting System
by Shouzhong Feng, Deyuan Kan and Chao Guo
Fire 2025, 8(6), 216; https://doi.org/10.3390/fire8060216 - 28 May 2025
Viewed by 803
Abstract
This study presents a novel water mist fire fighting system that integrates water mist sprays and water mist curtains, designed to achieve simultaneous fire suppression, thermal insulation, and smoke control. Three full-scale experiments were conducted under various fire scenarios, and the changes in [...] Read more.
This study presents a novel water mist fire fighting system that integrates water mist sprays and water mist curtains, designed to achieve simultaneous fire suppression, thermal insulation, and smoke control. Three full-scale experiments were conducted under various fire scenarios, and the changes in fire behavior and heat release rate were examined to evaluate the effectiveness of the water mist system in extinguishing fires. Additionally, the spatiotemporal changes in ceiling temperature were monitored to assess the cooling and protective effects of the water mist. The thermal insulation capability of the system was also investigated by detecting the temperature distribution inside the tunnel. Moreover, the smoke conditions upstream and downstream of the tunnel were analyzed to evaluate the smoke-blocking performance of the water mist system. The findings demonstrate that the water mist fire fighting system is highly efficient in attenuating the fire and restricting its progression. Within the water mist spray section, the average ceiling temperature decreased exponentially during both the initial and steady burning phases across all tested fire scenarios. Nonetheless, the smoke-carrying capacity of the water mist spray is limited. Fortunately, the dispersed smoke was diluted by water mist, markedly enhancing visibility and mitigating the impact of smoke on tunnel illumination. Full article
Show Figures

Figure 1

22 pages, 10463 KB  
Article
The Effect of Toxicity, Physical and Thermal Properties of Fire Blanket Made of Glass Fiber on Its Quality as Small Fire Suppression Tool
by Mohamed A. Hassan, Mohamed M. AlSofian, Ahmed Al Zharani, Mohammed R. AlOtaibi, Sami Al Saeed and Naif Al Anazi
Fire 2025, 8(5), 191; https://doi.org/10.3390/fire8050191 - 9 May 2025
Viewed by 690
Abstract
The use of fiberglass blankets as fire suppression blankets to extinguish accidental cooking fires has been regulated and widely used, especially in homes and small firms and laboratories. Understanding the properties, which have significant effect on their performance, is essential for ensuring effective [...] Read more.
The use of fiberglass blankets as fire suppression blankets to extinguish accidental cooking fires has been regulated and widely used, especially in homes and small firms and laboratories. Understanding the properties, which have significant effect on their performance, is essential for ensuring effective fire control and improving the quality of these blankets in fire suppression. This study examines key properties including toxicity, physical characteristics, thermal behavior, and fire suppression capabilities. Novel properties such as air permeability and spectroscopic structural analysis are explored, areas previously under-researched. The sample number S4 had Warp/weft count 21/12 with comparison to air permeability; it gave the lowest value among the selected samples. Thermal properties, including heat transfer and temperature dynamics, are also analyzed to understand how fire spreads through the material. The optimal performance of air permeability was observed to be below 650 L/m2/s. Blankets demonstrated over 45% heat blocking efficiency at low heat flux and more than 78% at high heat flux. Temperature rise within the first minute of fire exposure is a key determinant, with effective blankets maintaining temperatures below 300 °C after one minute and ensuring that the final temperature after three minutes does not exceed 390–400 °C. Additionally, a new classification system based on the toxicity of gases emitted during combustion was introduced, enhancing the safety profile of fiberglass blankets and improving their suitability for practical use. This research contributes valuable insights into both the performance and safety of fiberglass fire blankets Full article
Show Figures

Figure 1

16 pages, 951 KB  
Article
A Water-Based Fire-Extinguishing Agent of Lithium Iron Phosphate Battery Fire via an Analytic Hierarchy Process-Fuzzy TOPSIS Decision-Marking Method
by Shuai Yuan, Kuo Wang, Feng Tai, Donghao Cheng, Qi Zhang, Yujie Cui, Xinming Qian, Chunwen Sun, Song Liu and Xin Chen
Batteries 2025, 11(5), 182; https://doi.org/10.3390/batteries11050182 - 2 May 2025
Cited by 1 | Viewed by 690
Abstract
It is well known that the safety concerns surrounding lithium-ion batteries (LIBs), such as fire and explosion, are currently a bottleneck problem for the large-scale usage of energy storage power stations. The study of water-based fire-extinguishing agents used for LIBs is a promising [...] Read more.
It is well known that the safety concerns surrounding lithium-ion batteries (LIBs), such as fire and explosion, are currently a bottleneck problem for the large-scale usage of energy storage power stations. The study of water-based fire-extinguishing agents used for LIBs is a promising direction. How to choose a suitable water-based fire-extinguishing agent is a significant scientific problem. In this study, a comprehensive evaluation model, including four primary indexes and eleven secondary indexes was established, which was used in the scenario of an electrochemical energy storage power station. The model is only suitable for assessing water-based fire extinguishing for suppressing lithium iron phosphate battery fire. Based on the comprehensive evaluation index system and extinguishing experiment data, the analytic hierarchy process (AHP) combined with fuzzy TOPSIS was used to evaluate the performances of the three kinds of water-based fire-extinguishing agents. According to the results of the fuzzy binary contrast method, the three kinds of fire-extinguishing agents could be ranked as follows: YS1000 > F-500 additive > pure water. The study provided a method for choosing and preparing a suitable fire-extinguishing agent for lithium iron phosphate batteries. Full article
Show Figures

Figure 1

23 pages, 6824 KB  
Article
Study on the Influence of Expansion Ratio on the Effectiveness of Foam in Suppressing Forest Surface Fires
by Haiyan Wang, Junzhao Zhang, Hongbin Zhong and Lei Chen
Fire 2025, 8(5), 171; https://doi.org/10.3390/fire8050171 - 28 Apr 2025
Cited by 1 | Viewed by 868
Abstract
Firefighting foam is widely recognized for its excellent fire suppression performance. However, research on the effect of foam expansion ratio on the suppression efficiency of forest surface fires remains limited. In this study, the expansion ratio was adjusted by varying the air-to-liquid ratio [...] Read more.
Firefighting foam is widely recognized for its excellent fire suppression performance. However, research on the effect of foam expansion ratio on the suppression efficiency of forest surface fires remains limited. In this study, the expansion ratio was adjusted by varying the air-to-liquid ratio in a compressed air foam system, and laboratory-scale foam suppression experiments were conducted. Key performance indicators, including extinguishing coverage time, internal cooling rate, and resistance to reignition, were systematically measured. The effects of expansion ratio on the diffusion and penetration behavior of foam on the fuel bed surface were then investigated to understand how these characteristics influence suppression performance. The results indicate that both excessively low and high expansion ratios can weaken fire suppression effectiveness. Low-expansion foam, characterized by low viscosity and high water content, exhibits strong local penetration and cooling capabilities. However, it struggles to rapidly cover the fuel bed surface and isolate oxygen, thereby reducing the overall suppression efficiency. In contrast, high-expansion foam has greater viscosity, allowing it to spread across the fuel bed surface under pressure gradient forces and form a stable coverage layer, effectively limiting the oxygen supply required for combustion. However, its limited depth penetration and lower water content reduce internal cooling efficiency, increasing the risk of reignition. The optimal expansion ratio was determined to be 15.1. Additionally, increasing the liquid supply flow rate significantly improved suppression performance; however, this improvement plateaued when the flow rate exceeded 10 L/min. Full article
(This article belongs to the Special Issue Firefighting Approaches and Extreme Wildfires)
Show Figures

Figure 1

44 pages, 4223 KB  
Review
Classification and Prevention of Electrical Fires: A Comprehensive Review
by Guohui Li, Jiapu Guo, Yanhao Kang, Que Huang, Junchao Zhao and Changcheng Liu
Fire 2025, 8(4), 154; https://doi.org/10.3390/fire8040154 - 10 Apr 2025
Cited by 2 | Viewed by 2114
Abstract
With the development of society and the advancement of technology, the application of electricity in modern life has become increasingly widespread. However, the risk of electrical fires has also significantly increased. This paper thoroughly investigates the causes, classifications, and challenges of electrical fires [...] Read more.
With the development of society and the advancement of technology, the application of electricity in modern life has become increasingly widespread. However, the risk of electrical fires has also significantly increased. This paper thoroughly investigates the causes, classifications, and challenges of electrical fires in special environments, and summarizes advanced detection and extinguishing technologies. The study reveals that the causes of electrical fires are complex and diverse, including equipment aging, improper installation, short circuits, and overloading. In special environments such as submarines, surface vessels, and aircraft, the risk of electrical fires is higher due to limited space, dense equipment, and difficult rescue operations. This paper also provides a detailed analysis of various types of electrical fires, including cable fires, electrical cabinet fires, transformer fires, battery fires, data center fires, and residential fires, and discusses their characteristics and prevention and control technologies. In terms of detection technology, this paper summarizes the progress of technologies such as arc detection, video detection, and infrared thermography, and emphasizes the importance of selecting appropriate technologies based on specific environments. Regarding extinguishing technologies, this paper discusses various means of extinguishing, such as foam extinguishing agents, dry powder extinguishing agents, and fine water mist technology, and highlights their advantages, disadvantages, and applicable scenarios. Finally, this paper identifies the limitations in the current field of electrical fire prevention and control, emphasizes the importance of interdisciplinary research and the development of advanced risk assessment models, and outlines future research directions. Full article
(This article belongs to the Special Issue Building Fires, Evacuations and Rescue)
Show Figures

Figure 1

Back to TopTop