Microwave Imaging for Parkinson’s Disease Detection: A Phantom-Based Feasibility Study Using Temperature-Controlled Dielectric Variations
by Leonardo Cardinali, David O. Rodriguez-Duarte, Jorge A. Tobón Vasquez, Francesca Vipiana and Luis Jofre-Roca
Sensors 2025, 25(24), 7562; https://doi.org/10.3390/s25247562 - 12 Dec 2025
Viewed by 826
Abstract
Parkinson’s disease (PD) is characterized by pathological changes in the substantia nigra, which in its early stages may manifest as structural and functional asymmetries between the two hemispheres. Microwave imaging has recently emerged as a promising non-invasive tool to detect subtle dielectric variations. [...] Read more.
Parkinson’s disease (PD) is characterized by pathological changes in the substantia nigra, which in its early stages may manifest as structural and functional asymmetries between the two hemispheres. Microwave imaging has recently emerged as a promising non-invasive tool to detect subtle dielectric variations. In the context of Parkinson’s disease, such contrasts are expected to arise from the underlying physiological alterations in brain tissue, although their magnitude has not yet been fully characterized. In this work, we investigate the feasibility of differential microwave imaging, where detection is based on permittivity contrasts, through a controlled phantom study. A simple two-dimensional head phantom was constructed using a 3D-printed cylindrical container filled with water, incorporating a Teflon tube to represent the substantia nigra. The tube was filled with hot water, whose gradual cooling emulated small dielectric changes. Since the dielectric properties of water vary linearly with temperature over 0.5–3 GHz, we first validated this dependence through both numerical analysis and experimental measurements. Four antennas were then employed in a differential imaging configuration, with image reconstruction performed via the multi-frequency bi-focusing algorithm. The results show that the system can successfully detect a dielectric contrast corresponding to a temperature variation as small as 0.4 °C, equivalent to approximately 0.17% in relative permittivity. While the exact dielectric changes associated with PD remain to be determined, these results demonstrate that the proposed approach is sensitive to very small contrasts, supporting the potential of differential microwave imaging as a candidate tool for future investigations into Parkinson’s disease detection. Full article
Show Figures

Figure 1

18 pages, 2597 KB  
Article
Magnetisation Transfer 3D-Radial Zero Echo Time MR Imaging at 7T
by Mark Symms, Paulina Kozioł, Catarina Rua, Douglas Kelley, Natalia Pietroń, Katarzyna Wiśniewska, Anna Niedziałek, Anna Jamroz-Wiśniewska, Andrzej Stepniewski and Radosław Pietura
J. Clin. Med. 2025, 14(21), 7722; https://doi.org/10.3390/jcm14217722 - 30 Oct 2025
Viewed by 762
Abstract
Background/Objectives: Magnetisation Transfer (MT) MRI is used for neuro-degenerative disorders, including Multiple Sclerosis (MS), providing an indirect measure of large biomolecular MR signal sources which cannot be observed directly because their typical T2 is usually much shorter than the echo time (TE) [...] Read more.
Background/Objectives: Magnetisation Transfer (MT) MRI is used for neuro-degenerative disorders, including Multiple Sclerosis (MS), providing an indirect measure of large biomolecular MR signal sources which cannot be observed directly because their typical T2 is usually much shorter than the echo time (TE) of conventional MR sequences. We investigated a 3D-radial Zero Time of Echo (ZTE) MT-weighted sequence with potentially enhanced sensitivity to short-T2 MR signals indirectly (via MT weighting) and directly (due to the short TE). Methods: The sequence runs on a human 7T MR scanner, producing whole-brain MT-weighted images with isotropic 0.8 mm resolution in 6.5 minutes. One RF pulse is used to suppress the fat signal and generate MT weighting, reducing RF power deposition to moderate levels. The small excitation pulses and the “quasi-adiabatic” MT pulse mitigate the negative effects of inhomogeneous transmit RF fields observed at 7T in the human head, facilitating the generation of uniform Magnetisation Transfer Ratio (MTR) maps. Results: Results from a biologic phantom, a healthy volunteer, and an MS patient illustrate important imaging features of the “SilentMT” sequence. When the MS patient images were compared with Fluid Attenuated Inversion Recovery (FLAIR) images taken on the same patient at 1.5T and 7T, SilentMT was able to detect all the MS lesions observed on the “reference truth” 1.5T FLAIR; 7T FLAIR, however, failed to detect some lesions in the temporal lobe and brain stem. SilentMT detected a lesion which was not immediately apparent on either FLAIR image. Increased MTR was observed in some regions of the brain of the MS patient, notably the left temporal lobe. Conclusions: This initial investigation of an MT-weighted ZTE sequence shows evidence that it may be more sensitive to pathology in a patient with MS. Full article
(This article belongs to the Section Nuclear Medicine & Radiology)
Show Figures

Figure 1

19 pages, 2262 KB  
Article
Dose-Dependent Analysis of Image Quality in Pediatric Head CT Scans Across Different Scanners to Optimize Clinical Protocols Using Phantom-Based Assessment
by Hiroshi Kuwahara, Mitsuaki Ojima, Tsuneko Kawamura, Daisuke Saitou, Kazunari Andou, Eiji Ariga, Kotaro Hasegawa and Michiaki Kai
Tomography 2025, 11(11), 119; https://doi.org/10.3390/tomography11110119 - 27 Oct 2025
Viewed by 1278
Abstract
Background/Objectives: Optimization of pediatric head computed tomography (CT) protocols is essential to minimize radiation exposure while maintaining diagnostic image quality. Previous studies mainly relied on phantom-based measurements or visual assessments, and validation using clinical images remains limited. This study aimed to establish quantitative [...] Read more.
Background/Objectives: Optimization of pediatric head computed tomography (CT) protocols is essential to minimize radiation exposure while maintaining diagnostic image quality. Previous studies mainly relied on phantom-based measurements or visual assessments, and validation using clinical images remains limited. This study aimed to establish quantitative thresholds for noise and contrast-to-noise ratio (CNR) in pediatric head CT by integrating multicenter clinical data with phantom evaluations. Methods: A multicenter retrospective study was conducted using CT systems from eight hospitals, combined with Catphan phantom experiments and pediatric head CT data. Scan parameters, automatic exposure control settings, and reconstruction methods were collected. Image quality was quantified by the standard deviation (SD) of noise and CNR obtained from regions of interest in gray and white matter. Radiation dose was represented by CTDIvol. Relationships among CTDIvol, SD, and CNR were analyzed across scanners from three manufacturers (Canon, FUJI, and GE). Results: Consistent dose–response trends were observed across institutions and manufacturers. Image noise decreased as CTDIvol increased, but reached a plateau at higher doses. CNR improved with dose escalation, then stabilized. Both phantom experiments and clinical analyses identified a target SD of 5 and CNR of 2 as optimal indicators for pediatric head CT. Conclusions: Quantitative thresholds were determined as practical indicators for balancing diagnostic image quality with dose reduction. Further reduction may be achieved through advanced reconstruction methods, such as deep learning-based algorithms. These findings may contribute to standardizing pediatric head CT protocols and supporting safer and more effective diagnostic imaging. Full article
Show Figures

Graphical abstract

23 pages, 4599 KB  
Review
In Vitro Evaluation of Confounders in Brain Optical Monitoring: A Review
by Karina Awad-Pérez, Maria Roldan and Panicos A. Kyriacou
Sensors 2025, 25(18), 5654; https://doi.org/10.3390/s25185654 - 10 Sep 2025
Viewed by 1241
Abstract
Optical brain monitoring techniques, including near-infrared spectroscopy (NIRS), diffuse correlation spectroscopy (DCS), and photoplethysmography (PPG) have gained attention for their non-invasive, affordable, and portable nature. These methods offer real-time insights into cerebral parameters like cerebral blood flow (CBF), intracranial pressure (ICP), and oxygenation. [...] Read more.
Optical brain monitoring techniques, including near-infrared spectroscopy (NIRS), diffuse correlation spectroscopy (DCS), and photoplethysmography (PPG) have gained attention for their non-invasive, affordable, and portable nature. These methods offer real-time insights into cerebral parameters like cerebral blood flow (CBF), intracranial pressure (ICP), and oxygenation. However, confounding factors like extracerebral layers, skin pigmentation, skull thickness, and brain-related pathologies may affect measurement accuracy. This review examines the potential impact of confounders, focusing on in vitro studies that use phantoms to simulate human head properties under controlled conditions. A systematic search identified six studies on extracerebral layers, two on skin pigmentation, two on skull thickness, and four on brain pathologies. While variation in phantom designs and optical devices limits comparability, findings suggest that the extracerebral layer and skull thickness influence measurement accuracy, and skin pigmentation introduces bias. Pathologies like oedema and haematomas affect the optical signal, though their influence on parameter estimation remains inconclusive. This review highlights limitations in current research and identifies areas for future investigation, including the need for improved brain phantoms capable of simulating pulsatile signals to assess the impact of confounders on PPG systems, given the growing interest in PPG-based cerebral monitoring. Addressing these challenges will improve the reliability of optical monitoring technologies. Full article
(This article belongs to the Collection Sensors for Globalized Healthy Living and Wellbeing)
Show Figures

Figure 1

15 pages, 3262 KB  
Article
Comparison of a Multi-Scenario Robustness Evaluation Method with Measurements for Proton Teletherapy
by Qiangxing Yang, Michael F. Moyers and Zhuangming Shen
Cancers 2025, 17(17), 2927; https://doi.org/10.3390/cancers17172927 - 6 Sep 2025
Viewed by 2022
Abstract
Background/Objectives: Multi-scenario calculational methods have been used to evaluate proton teletherapy plan robustness but few studies have been performed to determine the accuracy of these calculational methods. This study evaluates a multi-scenario method by comparing calculations to measurements made in phantoms that [...] Read more.
Background/Objectives: Multi-scenario calculational methods have been used to evaluate proton teletherapy plan robustness but few studies have been performed to determine the accuracy of these calculational methods. This study evaluates a multi-scenario method by comparing calculations to measurements made in phantoms that simulate the effects of possible uncertainties. Methods: Plans were made using four phantoms in which the delivered dose was highly sensitive to positional and penetration uncertainties. The effects of alignment and penetration uncertainties on the dose distributions of each of those phantoms were simulated by performing calculations using nine different uncertainty scenarios and comparing the calculations to measurements with induced physical alignment displacements. Measured dose distributions were obtained by exposing films placed inside the phantoms and extracting multiple linear profiles. The maximum and minimum doses obtained for each of the calculational scenarios were compared with the measured dose profiles. In addition, comparisons of DVHs for nominal and uncertainty scenarios were performed. Results: The results showed that, under the influence of uncertainties, the minimum dose for the four phantoms decreased by more than 20 Gy, the V95% coverage fluctuated by more than 10%, but the maximum dose parameter changed by less than 5 Gy. This was expected, as no margins for uncertainties were applied around the targets. The envelope bounded by the maximum and minimum possible calculated doses contained most of the measurements, although the shapes of the dose profiles displayed some mismatches for wedge and head phantoms. There were a few points where the measured maximum dose for bone and lung slab phantom cases was slightly higher than the maximum dose calculated from the nine scenarios. Conclusions: This study demonstrates that a nine-scenario method can adequately evaluate the robustness of simple mono-directional plans containing heterogeneities. Full article
(This article belongs to the Special Issue The Advance of Pencil Beam Scanning Proton Beam Therapy in Cancers)
Show Figures

Figure 1

17 pages, 4473 KB  
Article
Dual-Band Wearable Antenna Integrated with Glasses for 5G and Wi-Fi Systems
by Łukasz Januszkiewicz
Appl. Sci. 2025, 15(14), 8018; https://doi.org/10.3390/app15148018 - 18 Jul 2025
Cited by 2 | Viewed by 1529
Abstract
This paper presents a dual-band antenna designed for integration into eyewear. The antenna is intended for a system supporting visually impaired individuals, where a wearable camera integrated into glasses transmits data to a remote receiver. To enhance system reliability within indoor environments, the [...] Read more.
This paper presents a dual-band antenna designed for integration into eyewear. The antenna is intended for a system supporting visually impaired individuals, where a wearable camera integrated into glasses transmits data to a remote receiver. To enhance system reliability within indoor environments, the proposed design supports both fifth-generation (5G) wireless communication and Wi-Fi networks. The compact antenna is specifically dimensioned for integration within eyeglass temples and operates in the 3.5 GHz and 5.8 GHz frequency bands. Prototype measurements, conducted using a human head phantom, validate the antenna’s performance. The results demonstrate good impedance matching across the desired frequency bands and a maximum gain of at least 4 dBi in both bands. Full article
(This article belongs to the Special Issue Antenna Technology for 5G Communication)
Show Figures

Figure 1

17 pages, 2879 KB  
Article
The Impact of Integrating 3D-Printed Phantom Heads of Newborns with Cleft Lip and Palate into an Undergraduate Orthodontic Curriculum: A Comparison of Learning Outcomes and Student Perception
by Sarah Bühling, Jakob Stuhlfelder, Hedi Xandt, Sara Eslami, Lukas Benedikt Seifert, Robert Sader, Stefan Kopp, Nicolas Plein and Babak Sayahpour
Dent. J. 2025, 13(7), 323; https://doi.org/10.3390/dj13070323 - 16 Jul 2025
Viewed by 1344
Abstract
Background/Objectives: This prospective intervention study examined the learning effect of using 3D-printed phantom heads with cleft lip and palate (CLP) and upper jaw models with CLP and maxillary plates during a lecture for dental students in their fourth year at J. W. [...] Read more.
Background/Objectives: This prospective intervention study examined the learning effect of using 3D-printed phantom heads with cleft lip and palate (CLP) and upper jaw models with CLP and maxillary plates during a lecture for dental students in their fourth year at J. W. Goethe Frankfurt University. The primary aim was to evaluate the impact of 3D-printed models on students’ satisfaction levels along with their understanding and knowledge in dental education. Methods: Six life-sized phantom heads with removable mandibles (three with unilateral and three with bilateral CLP) were designed using ZBrush software (Pixologic Inc., Los Angeles, CA, USA) based on MRI images and printed with an Asiga Pro 4K 3D printer (Asiga, Sydney, Australia). Two groups of students (n = 81) participated in this study: the control (CTR) group (n = 39) attended a standard lecture on cleft lip and palate, while the intervention (INT) group (n = 42) participated in a hands-on seminar with the same theoretical content, supplemented by 3D-printed models. Before and after the session, students completed self-assessment questionnaires and a multiple-choice test to evaluate knowledge improvement. Data analysis was conducted using the chi-square test for individual questions and the Wilcoxon rank test for knowledge gain, with the significance level set at 0.05. Results: The study demonstrated a significant knowledge increase in both groups following the lecture (p < 0.001). Similarly, there were significant differences in students’ self-assessments before and after the session (p < 0.001). The knowledge gain in the INT group regarding the anatomical features of unilateral cleft lip and palate was significantly higher compared to that in the CTR group (p < 0.05). Conclusions: The results of this study demonstrate the measurable added value of using 3D-printed models in dental education, particularly in enhancing students’ understanding of the anatomy of cleft lip and palate. Full article
(This article belongs to the Special Issue Dental Education: Innovation and Challenge)
Show Figures

Figure 1

16 pages, 2092 KB  
Article
Augmented Reality-Assisted Placement of Surgical Guides and Osteotomy Execution for Pelvic Tumour Resections: A Pre-Clinical Feasibility Study Using 3D-Printed Models
by Tanya Fernández-Fernández, Javier Orozco-Martínez, Amaia Iribar-Zabala, Elena Aguilera Jiménez, Carla de Gregorio-Bermejo, Lydia Mediavilla-Santos, Javier Pascau, Mónica García-Sevilla, Rubén Pérez-Mañanes and Jose Antonio Calvo-Haro
Cancers 2025, 17(13), 2260; https://doi.org/10.3390/cancers17132260 - 7 Jul 2025
Cited by 2 | Viewed by 1064
Abstract
Objectives: This pre-clinical feasibility study evaluates the accuracy of a novel augmented reality-based (AR-based) guidance technology using head-mounted displays (HMDs) for the placement of patient-specific instruments (PSIs)—also referred to as surgical guides—and osteotomy performance in pelvic tumour resections. The goal is to [...] Read more.
Objectives: This pre-clinical feasibility study evaluates the accuracy of a novel augmented reality-based (AR-based) guidance technology using head-mounted displays (HMDs) for the placement of patient-specific instruments (PSIs)—also referred to as surgical guides—and osteotomy performance in pelvic tumour resections. The goal is to improve PSI placement accuracy and osteotomy execution while assessing user perception and workflow efficiency. Methods: The study was conducted on ten 3D-printed pelvic phantoms derived from CT scans of cadaveric specimens. Custom PSIs were designed and printed to guide osteotomies at the supraacetabular, symphysial, and ischial regions. An AR application was developed for the HoloLens 2 HMD to display PSI location and cutting planes. The workflow included manual supraacetabular PSI placement, AR-guided placement of the other PSIs and osteotomy execution. Postoperative CT scans were analysed to measure angular and distance errors in PSI placement and osteotomies. Task times and user feedback were also recorded. Results: The mean angular deviation for PSI placement was 2.20°, with a mean distance error of 1.19 mm (95% CI: 0.86 to 1.52 mm). Osteotomies showed an overall mean angular deviation of 3.73° compared to planned cuts, all within the predefined threshold of less than 5°. AR-assisted guidance added less than two minutes per procedure. User feedback highlighted the intuitive interface and high usability, especially for visualising cutting planes. Conclusions: Integrating AR through HMDs is a feasible and accurate method for enhancing PSI placement and osteotomy performance in pelvic tumour resections. The system provides reliable guidance even in cases of PSI failure and adds minimal time to the surgical workflow while significantly improving accuracy. Further validation in cadaveric models is needed to ensure its clinical applicability. Full article
(This article belongs to the Special Issue Clinical Treatment of Osteosarcoma)
Show Figures

Figure 1

12 pages, 2660 KB  
Article
Fast and Fractionated: Correlation of Dose Attenuation and the Response of Human Cancer Cells in a New Anthropomorphic Brain Phantom
by Bernd Frerker, Elette Engels, Jason Paino, Vincent de Rover, John Paul Bustillo, Marie Wegner, Matthew Cameron, Stefan Fiedler, Daniel Häusermann, Guido Hildebrandt, Michael Lerch and Elisabeth Schültke
Biomimetics 2025, 10(7), 440; https://doi.org/10.3390/biomimetics10070440 - 3 Jul 2025
Cited by 2 | Viewed by 1202
Abstract
The results of radiotherapy in patients with primary malignant brain tumors are extremely dissatisfactory: the overall survival after a diagnosis of glioblastoma is typically less than three years. The development of spatially fractionated radiotherapy techniques could help to improve this bleak prognosis. In [...] Read more.
The results of radiotherapy in patients with primary malignant brain tumors are extremely dissatisfactory: the overall survival after a diagnosis of glioblastoma is typically less than three years. The development of spatially fractionated radiotherapy techniques could help to improve this bleak prognosis. In order to develop technical equipment and organ-specific therapy plans, dosimetry studies as well as radiobiology studies are conducted. Although perfect spheres are considered optimal phantoms by physicists, this does not reflect the wide variety of head sizes and shapes in our patient community. Depth from surface and X-ray dose absorption by tissue between dose entry point and target, two key parameters in medical physics planning, are largely determined by the shape and thickness of the skull bone. We have, therefore, designed and produced a biomimetic tool to correlate measured technical dose and biological response in human cancer cells: a brain phantom, produced from tissue-equivalent materials. In a first pilot study, utilizing our phantom to correlate technical dose measurements and metabolic response to radiation in human cancer cell lines, we demonstrate why an anthropomorphic phantom is preferable over a simple spheroid phantom. Full article
Show Figures

Graphical abstract

14 pages, 2941 KB  
Article
Correction of Gradient Nonlinearity Bias in Apparent Diffusion Coefficient Measurement for Head and Neck Cancers Using Single- and Multi-Shot Echo Planar Diffusion Imaging
by Ramesh Paudyal, Alfonso Lema-Dopico, Akash Deelip Shah, Vaios Hatzoglou, Muhammad Awais, Eric Aliotta, Victoria Yu, Thomas L. Chenevert, Dariya I. Malyarenko, Lawrence H. Schwartz, Nancy Lee and Amita Shukla-Dave
Cancers 2025, 17(11), 1796; https://doi.org/10.3390/cancers17111796 - 28 May 2025
Cited by 1 | Viewed by 1660
Abstract
Background/Objectives: This work prospectively evaluates the vendor-provided Low Variance (LOVA) apparent diffusion coefficient (ADC) gradient nonlinearity correction (GNC) technique for primary tumors, neck nodal metastases, and normal masseter muscles in patients with head and neck cancers (HNCs). Methods: Multiple b-value diffusion-weighted (DW)-MR [...] Read more.
Background/Objectives: This work prospectively evaluates the vendor-provided Low Variance (LOVA) apparent diffusion coefficient (ADC) gradient nonlinearity correction (GNC) technique for primary tumors, neck nodal metastases, and normal masseter muscles in patients with head and neck cancers (HNCs). Methods: Multiple b-value diffusion-weighted (DW)-MR images were acquired on a 3.0 T scanner using a single-shot echo planar imaging (SS-EPI) and multi-shot (MS)-EPI for diffusion phantom materials (20% and 40% polyvinylpyrrolidone (PVP) in water). Pretreatment DW-MRI acquisitions were performed for sixty HNC patients (n = 60) who underwent chemoradiation therapy. ADC values with and without GNC were calculated offline using a monoexponential diffusion model over all b-values, relative percentage (r%) changes (Δ) in ADC values with and without GNC were calculated, and the ADC histograms were analyzed. Results: Mean ADC values calculated using SS-EPI DW data with and without GNC differed by ≤1% for both PVP20% and PVP40% at the isocenter, whereas off-center differences were ≤19.6% for both concentrations. A similar trend was observed for these materials with MS-EPI. In patients, the mean rΔADC (%) values measured with SS-EPI differed by 4.77%, 3.98%, and 5.68% for primary tumors, metastatic nodes, and masseter muscle. MS-EPI exhibited a similar result with 5.56%, 3.95%, and 4.85%, respectively. Conclusions: This study showed that the GNC method improves the robustness of the ADC measurement, enhancing its value as a quantitative imaging biomarker used in HNC clinical trials. Full article
Show Figures

Figure 1

19 pages, 1971 KB  
Article
Safety of Simultaneous Scalp and Intracranial EEG and fMRI: Evaluation of RF-Induced Heating
by Hassan B. Hawsawi, Anastasia Papadaki, Vejay N. Vakharia, John S. Thornton, David W. Carmichael, Suchit Kumar and Louis Lemieux
Bioengineering 2025, 12(6), 564; https://doi.org/10.3390/bioengineering12060564 - 24 May 2025
Viewed by 2264
Abstract
The acquisition of electroencephalography (EEG) concurrently with functional magnetic resonance imaging (fMRI) requires a careful consideration of the health hazards resulting from interactions between the scanner’s electromagnetic fields and EEG recording equipment. The primary safety concern is excessive RF-induced heating of the tissue [...] Read more.
The acquisition of electroencephalography (EEG) concurrently with functional magnetic resonance imaging (fMRI) requires a careful consideration of the health hazards resulting from interactions between the scanner’s electromagnetic fields and EEG recording equipment. The primary safety concern is excessive RF-induced heating of the tissue in the vicinity of electrodes. We have previously demonstrated that concurrent intracranial EEG (icEEG) and fMRI data acquisitions (icEEG-fMRI) can be performed with acceptable risk in specific conditions using a head RF transmit coil. Here, we estimate the potential additional heating associated with the addition of scalp EEG electrodes using a body transmit RF coil. In this study, electrodes were placed in clinically realistic positions on a phantom in two configurations: (1) icEEG electrodes only, and (2) following the addition of subdermal scalp electrodes. Heating was measured during MRI scans using a body transmit coil with a high specific absorption rate (SAR), TSE (turbo spin echo), and low SAR gradient-echo EPI (echo-planar imaging) sequences. During the application of the high-SAR sequence, the maximum temperature change for the intracranial electrodes was +2.8 °C. The addition of the subdural scalp EEG electrodes resulted in a maximum temperature change for the intracranial electrodes of 2.1 °C and +0.6 °C across the scalp electrodes. For the low-SAR sequence, the maximum temperature increase across all intracranial and scalp electrodes was +0.7 °C; in this condition, the temperature increases around the intracranial electrodes were below the detection level. Therefore, in the experimental conditions (MRI scanner, electrode, and wire configurations) used at our centre for icEEG-fMRI, adding six scalp EEG electrodes did not result in significant additional localised RF-induced heating compared to the model using icEEG electrodes only. Full article
(This article belongs to the Special Issue Multimodal Neuroimaging Techniques: Progress and Application)
Show Figures

Figure 1

13 pages, 2975 KB  
Article
Impact of Pseudo-Random Number Generators on Dosimetric Parameters in Validation of Medical Linear Accelerator Head Simulation for 6 MV Photons Using the GATE/GEANT4 Platform
by Meriem Tantaoui, Mustapha Krim, El Mehdi Essaidi, Othmane Kaanouch, Mohammed Reda Mesradi, Abdelkrim Kartouni and Souha Sahraoui
Quantum Beam Sci. 2025, 9(2), 16; https://doi.org/10.3390/qubs9020016 - 5 May 2025
Cited by 1 | Viewed by 1569
Abstract
Monte Carlo simulation relies on pseudo-random number generators. In general, the quality of these generators can have a direct impact on simulation results. The GATE toolbox, widely adopted in radiotherapy, offers three generators from which users can choose: Mersenne Twister, Ranlux-64, and James-Random. [...] Read more.
Monte Carlo simulation relies on pseudo-random number generators. In general, the quality of these generators can have a direct impact on simulation results. The GATE toolbox, widely adopted in radiotherapy, offers three generators from which users can choose: Mersenne Twister, Ranlux-64, and James-Random. In this study, we used these generators to simulate the head of a medical linear accelerator for 6 MV photons in order to assess their potential impact on the results obtained in radiotherapy simulation. Simulations were conducted for four different field openings. The simulations included a linac head model and a water phantom, all components of the head of the medical linear accelerator, and a water phantom placed at a distance of 100 cm from the electron source. Statistical analysis based on normal probability and Bland–Altman plots were used to compare dose distributions in the voxelized water phantom obtained by each generator. Experimental data (dose profiles, percentage dose at depth, and other dosimetric parameters) were measured using an appropriate quality assurance protocol for comparison with the different simulations. The evaluation of dosimetric criteria shows significant variations, particularly in the physical penumbra of the dose profile for large fields. The gamma index analysis highlights significant distinctions in generator performance. In all simulations, the average time of the primary particle generation rate, number of tracks, and steps in the simulation of different random number generators showed differences. The Mersenne Twister generator was distinguished by high performance in several aspects, particularly in terms of execution time, primary particle production, track and step production flow rate, and coming closer to the experimental results. Regarding computational time, the simulation using the Mersenne Twister generator was about 18% faster than the one using the James-Random generator and 27% faster than the simulation using the Ranlux-64 generator. This suggests that this generator is the most reliable for accurate and fast modeling of the medical linear accelerator head for 6 MV energy. Full article
(This article belongs to the Section Radiation Scattering Fundamentals and Theory)
Show Figures

Figure 1

17 pages, 5790 KB  
Article
Early Detection of Alzheimer’s Disease via Machine Learning-Based Microwave Sensing: An Experimental Validation
by Leonardo Cardinali, Valeria Mariano, David O. Rodriguez-Duarte, Jorge A. Tobón Vasquez, Rosa Scapaticci, Lorenzo Crocco and Francesca Vipiana
Sensors 2025, 25(9), 2718; https://doi.org/10.3390/s25092718 - 25 Apr 2025
Cited by 5 | Viewed by 2681
Abstract
The early diagnosis of Alzheimer’s disease remains an unmet medical need due to the cost and invasiveness of current methods. Early detection would ensure a higher quality of life for patients, enabling timely and suitable treatment. We investigate microwave sensing for low-cost, non-intrusive [...] Read more.
The early diagnosis of Alzheimer’s disease remains an unmet medical need due to the cost and invasiveness of current methods. Early detection would ensure a higher quality of life for patients, enabling timely and suitable treatment. We investigate microwave sensing for low-cost, non-intrusive early detection and assessment of Alzheimer’s disease. This study is based on the emerging evidence that the electromagnetic properties of cerebrospinal fluid are affected by abnormal concentrations of proteins recognized as early-stage biomarkers. We design a conformal six-element antenna array placed on the upper portion of the head, operating in the 500 MHz to 6.5 GHz band. It measures scattering response due to changes in the dielectric properties of intracranial cerebrospinal fluid. A multi-layer perceptron network extracts the diagnostic information. Data classification consists of two steps: binary classification to identify the disease presence and multi-class classification to evaluate its stage. The algorithm is trained and validated through controlled experiments mimicking various pathological severities with an anthropomorphic multi-tissue head phantom. Results support the feasibility of the proposed method using only amplitude data and lay the foundation for more extensive studies on microwave sensing for early Alzheimer’s detection. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

13 pages, 5782 KB  
Article
Neonatal Electroencephalogram Recording with a Dry Electrode Cap: A Feasibility Study
by Amirreza Asayesh, Indhika Fauzhan Warsito, Jens Haueisen, Patrique Fiedler and Sampsa Vanhatalo
Sensors 2025, 25(3), 966; https://doi.org/10.3390/s25030966 - 5 Feb 2025
Cited by 4 | Viewed by 3502
Abstract
This study investigates the feasibility of a dry electrode cap design for neonatal electroencephalogram (EEG) recordings. Recordings on a phantom and a real infant are compared between a novel dry electrode cap and a clinically used gel-based electrode cap. The phantom recordings included [...] Read more.
This study investigates the feasibility of a dry electrode cap design for neonatal electroencephalogram (EEG) recordings. Recordings on a phantom and a real infant are compared between a novel dry electrode cap and a clinically used gel-based electrode cap. The phantom recordings included measuring both the electrode contact force and the signal quality during still and respiration-like head motion. The real infant recordings were assessed for the EEG signals’ spectral characteristics, including powerline interference. Compared to gel-based caps, the dry caps showed a largely comparable skin force, an expectedly greater sensitivity to motion-induced artifacts, and a slightly lower powerline interference. Recordings on the real infant showed no significant skin marks after using the dry electrode, and the spectral compositions were comparable between dry- and gel-based electrode caps. These findings suggest that neonatal EEG recordings with a dry electrode cap are technically feasible, but movement-related artifacts, such as respiration in a supine lying infant, may challenge long-term recordings of spontaneous EEG activity. Yet, the ease of use of dry electrode caps calls for future studies to define the optimal use case in neonatal recordings. Full article
(This article belongs to the Section Wearables)
Show Figures

Figure 1

12 pages, 1069 KB  
Article
Fetal Radiation Dose in Common Diagnostic Radiology Procedures for Pregnant Patients: Findings from In-Phantom Measurements
by Anja Tomić, Hrvoje Brkić, Tajana Turk, Mladen Kasabašić, Ivana Bjelobrk, Ivana Kralik, Francesca De Monte, Nicola Zancopè, Riccardo Lombardi, Marija Majer, Željka Knežević, Mercedes Horvat, Matko Škarica, Zrinka Marić, Dario Faj and Vjekoslav Kopačin
Appl. Sci. 2025, 15(3), 1143; https://doi.org/10.3390/app15031143 - 23 Jan 2025
Viewed by 6697
Abstract
The diagnosis of emergent conditions during pregnancy can be delayed due to insufficient knowledge of fetal radiation doses in different imaging modalities. The aim of this article is to investigate the ranges of fetal doses in most common diagnostic and interventional radiology procedures. [...] Read more.
The diagnosis of emergent conditions during pregnancy can be delayed due to insufficient knowledge of fetal radiation doses in different imaging modalities. The aim of this article is to investigate the ranges of fetal doses in most common diagnostic and interventional radiology procedures. Procedures were carried out on an anthropomorphic phantom, Tena, representing a pregnant woman in the 18th week of pregnancy with the fetus in breech position. Different clinical scenarios using computer tomography (CT), radiography, fluoroscopy and digital subtraction angiography were selected in three teaching hospitals. Measurements were performed using radiophotoluminescent glass dosimeters placed in dedicated holes in the fetal head and fetal body. Measured fetal doses were below 1 mGy when the fetus was not in the primary beam. The highest fetal doses, up to 47 mGy, were measured after a CT scan for polytrauma and up to 24 mGy after a CT scan of the abdomen and pelvis. Significant variability in fetal doses for the same procedure was found between different hospitals but within the same hospital also. All obtained results are below the threshold for deterministic effects given by the International Commission for Radiation Protection but can be reached with two or more imaging procedures employed. The variability in fetal doses for the same procedures highlights the need for the improved optimization of imaging protocols. Full article
(This article belongs to the Special Issue Advances and Applications of Medical Imaging Physics)