13 pages, 2894 KB  
Article
Performance Characterisation of the Airvo2TM Nebuliser Adapter in Combination with the Aerogen SoloTM Vibrating Mesh Nebuliser for in Line Aerosol Therapy during High Flow Nasal Oxygen Therapy
by Ronan MacLoughlin and Marc Mac Giolla Eain
Pharmaceutics 2024, 16(4), 565; https://doi.org/10.3390/pharmaceutics16040565 - 20 Apr 2024
Cited by 3 | Viewed by 3475
Abstract
High flow oxygen (HFO) therapy is a well-established treatment in respiratory disease. Concurrent aerosol delivery can greatly expediate their recovery. The aim of this work was to complete a comprehensive characterisation of one such HFO therapy system, the Airvo2TM, used in [...] Read more.
High flow oxygen (HFO) therapy is a well-established treatment in respiratory disease. Concurrent aerosol delivery can greatly expediate their recovery. The aim of this work was to complete a comprehensive characterisation of one such HFO therapy system, the Airvo2TM, used in combination with the Aerogen SoloTM vibrating mesh nebuliser. Representative adult, infant, and paediatric head models were connected to a breathing simulator via a collection filter placed at the level of the trachea. A tracheostomy interface and nasal cannulas were used to deliver the aerosol. Cannula size and gas flow rate were varied across the full operating range recommended by the manufacturer. The tracheal and emitted doses were quantified via UV-spectrophotometry. The aerosol droplet diameter at the exit of the nares and tracheal interface was measured via cascade impaction. High gas flow rates resulted in low emitted and tracheal doses (%). Nasal cannula size had no significant effect on the tracheal dose (%) available in infant and paediatric models. Higher gas flow rates resulted in smaller aerosol droplets at the exit of the nares and tracheostomy interface. Gas flow rate was found to be the primary parameter affecting aerosol delivery. Thus, gas flow rates should be kept low and where possible, delivered using larger nasal cannulas to maximise aerosol delivery. Full article
(This article belongs to the Section Drug Delivery and Controlled Release)
Show Figures

Figure 1

11 pages, 1742 KB  
Article
In-Line Aerosol Therapy via Nasal Cannula during Adult and Paediatric Normal, Obstructive, and Restrictive Breathing
by Marc Mac Giolla Eain and Ronan MacLoughlin
Pharmaceutics 2023, 15(12), 2679; https://doi.org/10.3390/pharmaceutics15122679 - 27 Nov 2023
Cited by 4 | Viewed by 2603
Abstract
High-flow nasal oxygen therapy is being increasingly adopted in intensive and home care settings. The concurrent delivery of aerosolised therapeutics allows for the targeted treatment of respiratory illnesses. This study examined in-line aerosol therapy via a nasal cannula to simulated adult and paediatric [...] Read more.
High-flow nasal oxygen therapy is being increasingly adopted in intensive and home care settings. The concurrent delivery of aerosolised therapeutics allows for the targeted treatment of respiratory illnesses. This study examined in-line aerosol therapy via a nasal cannula to simulated adult and paediatric models with healthy, obstructive and restrictive lung types. The Aerogen Solo vibrating mesh nebuliser was used in combination with the InspiredTM O2FLO high-flow therapy system. Representative adult and paediatric head models were connected to a breathing simulator, which replicated several different states of lung health. The aerosol delivery was quantified at the tracheal level using UV-spectrophotometry. Testing was performed at a range of supplemental gas flow rates applicable to both models. Positive end-expiratory pressure was measured pre-, during and post-nebulisation. The increases in supplemental gas flow rates resulted in a decrease in aerosol delivery, irrespective of lung health. Large tidal volumes and extended inspiratory phases were associated with the greatest aerosol delivery. Gas flow to inspiratory flow ratios of 0.29–0.5 were found to be optimum for aerosol delivery. To enhance aerosol delivery to patients receiving high-flow nasal oxygen therapy, respiratory therapists should keep supplemental gas-flow rates below the inspiratory flow of the patient. Full article
(This article belongs to the Special Issue Drug Delivery Systems for Respiratory Diseases)
Show Figures

Figure 1

17 pages, 1371 KB  
Article
Biopharmaceutical Assessment of Mesh Aerosolised Plasminogen, a Step towards ARDS Treatment
by Lucia Vizzoni, Chiara Migone, Brunella Grassiri, Ylenia Zambito, Baldassare Ferro, Paolo Roncucci, Filippo Mori, Alfonso Salvatore, Ester Ascione, Roberto Crea, Semih Esin, Giovanna Batoni and Anna Maria Piras
Pharmaceutics 2023, 15(6), 1618; https://doi.org/10.3390/pharmaceutics15061618 - 30 May 2023
Cited by 5 | Viewed by 3111
Abstract
Acute respiratory distress syndrome (ARDS) is a severe complication of lung injuries, commonly associated with bacterial, fungal and viral infections, including SARS-CoV-2 viral infections. ARDS is strongly correlated with patient mortality and its clinical management is very complex, with no effective treatment presently [...] Read more.
Acute respiratory distress syndrome (ARDS) is a severe complication of lung injuries, commonly associated with bacterial, fungal and viral infections, including SARS-CoV-2 viral infections. ARDS is strongly correlated with patient mortality and its clinical management is very complex, with no effective treatment presently available. ARDS involves severe respiratory failure, fibrin deposition in both airways and lung parenchyma, with the development of an obstructing hyaline membrane drastically limiting gas exchange. Moreover, hypercoagulation is related to deep lung inflammation, and a pharmacological action toward both aspects is expected to be beneficial. Plasminogen (PLG) is a main component of the fibrinolytic system playing key roles in various inflammation regulatory processes. The inhalation of PLG has been proposed in the form of the off-label administration of an eyedrop solution, namely, a plasminogen-based orphan medicinal product (PLG-OMP), by means of jet nebulisation. Being a protein, PLG is susceptible to partial inactivation under jet nebulisation. The aim of the present work is to demonstrate the efficacy of the mesh nebulisation of PLG-OMP in an in vitro simulation of clinical off-label administration, considering both the enzymatic and immunomodulating activities of PLG. Biopharmaceutical aspects are also investigated to corroborate the feasibility of PLG-OMP administration by inhalation. The nebulisation of the solution was performed using an Aerogen® SoloTM vibrating-mesh nebuliser. Aerosolised PLG showed an optimal in vitro deposition profile, with 90% of the active ingredient impacting the lower portions of a glass impinger. The nebulised PLG remained in its monomeric form, with no alteration of glycoform composition and 94% of enzymatic activity maintenance. Activity loss was observed only when PLG-OMP nebulisation was performed under simulated clinical oxygen administration. In vitro investigations evidenced good penetration of aerosolised PLG through artificial airway mucus, as well as poor permeation across an Air–Liquid Interface model of pulmonary epithelium. The results suggest a good safety profile of inhalable PLG, excluding high systemic absorption but with good mucus diffusion. Most importantly, the aerosolised PLG was capable of reversing the effects of an LPS-activated macrophage RAW 264.7 cell line, demonstrating the immunomodulating activity of PLG in an already induced inflammatory state. All physical, biochemical and biopharmaceutical assessments of mesh aerosolised PLG-OMP provided evidence for its potential off-label administration as a treatment for ARDS patients. Full article
(This article belongs to the Special Issue Inhaled Treatment of Respiratory Infections)
Show Figures

Figure 1

12 pages, 1013 KB  
Article
Characterisation of Particle Size and Viability of SARS-CoV-2 Aerosols from a Range of Nebuliser Types Using a Novel Sampling Technique
by Susan Paton, Simon Clark, Antony Spencer, Isobel Garratt, Ikshitaa Dinesh, Katy-Anne Thompson, Allan Bennett and Thomas Pottage
Viruses 2022, 14(3), 639; https://doi.org/10.3390/v14030639 - 19 Mar 2022
Cited by 15 | Viewed by 4283
Abstract
Little is understood about the impact of nebulisation on the viability of SARS-CoV-2. In this study, a range of nebulisers with differing methods of aerosol generation were evaluated to determine SARS-CoV-2 viability following aerosolization. The aerosol particle size distribution was assessed using an [...] Read more.
Little is understood about the impact of nebulisation on the viability of SARS-CoV-2. In this study, a range of nebulisers with differing methods of aerosol generation were evaluated to determine SARS-CoV-2 viability following aerosolization. The aerosol particle size distribution was assessed using an aerosol particle sizer (APS) and SARS-CoV-2 viability was determined after collection into liquid media using All-Glass Impingers (AGI). Viable particles of SARS-CoV-2 were further characterised using the Collison 6-jet nebuliser in conjunction with novel sample techniques in an Andersen size-fractioning sampler to predict lung deposition profiles. Results demonstrate that all the tested nebulisers can generate stable, polydisperse aerosols (Geometric standard deviation (GSD) circa 1.8) in the respirable range (1.2 to 2.2 µm). Viable fractions (VF, units PFU/particle, the virus viability as a function of total particles produced) were circa 5 × 10−3. VF and spray factors were not significantly affected by relative humidity, within this system where aerosols were in the spray tube an extremely short time. The novel Andersen sample collection methods successfully captured viable virus particles across all sizes; with most particle sizes below 3.3 µm. Particle sizes, in MMAD (Mass Median Aerodynamic Diameters), were calculated from linear regression of log10-log10 transformed cumulative PFU data, and calculated MMADs accorded well with APS measurements and did not differ across collection method types. These data will be vital in informing animal aerosol challenge models, and infection prevention and control policies. Full article
(This article belongs to the Special Issue Aerosol Transmission of Viral Disease)
Show Figures

Figure 1

11 pages, 544 KB  
Guidelines
Nebulisation Therapy in Patients with Cystic Fibrosis—Consensus of the Polish Cystic Fibrosis Society
by Katarzyna Walicka-Serzysko, Teresa Orlik, Dorota Sands, Natalia Jeneralska, Anna Popiel, Wojciech Skorupa, Andrzej Pogorzelski and Szczepan Cofta
Adv. Respir. Med. 2021, 89(6), 570-580; https://doi.org/10.5603/ARM.a2021.0107 - 9 Dec 2021
Cited by 5 | Viewed by 1375
Abstract
Introduction: Nebulisation therapy plays a key role in the treatment of cystic fibrosis (CF). Its effectiveness depends on obtaining a high concentration of drugs in the respiratory tract. Particle deposition is determined by many factors resulting, inter alia, from the essence of [...] Read more.
Introduction: Nebulisation therapy plays a key role in the treatment of cystic fibrosis (CF). Its effectiveness depends on obtaining a high concentration of drugs in the respiratory tract. Particle deposition is determined by many factors resulting, inter alia, from the essence of the lung disease (mucus, structural changes such as bronchiectasis, fibrous changes, cirrhosis) and the quality of the aerosol and breathing techniques during the procedure. Aims: A large variety of available drugs that can be used in the form of aerosols (bronchodilators, mucolytics, antibiotics), a wide range of devices for their delivery, and a different approach to the practical aspect related to the use of inhalation, makes it necessary to systematize knowledge in order to optimize nebulisation therapy. The paper presents an overview of inhaled drugs used in cystic fibrosis and their administration devices. Results: The principles of inhalation antibiotic therapy, which constitute the basis for the treatment of primary and chronic respiratory tract infections of Pseudomonas aeruginosa etiology, are discussed in detail. A very important issue was raised related to the proper selection of devices and their proper operation. In the context of the key role of nebulisation therapy in cystic fibrosis, a huge problem is the limited availability of inhaled antibiotics in Poland. Conclusions: The possibility of choosing an antibiotic and using alternating therapy increases the effectiveness of inhalation treatment, which results in slowing down the progress of bronchopulmonary disease and extending the life of patients. Full article
23 pages, 2179 KB  
Article
Nebulised Isotonic Hydroxychloroquine Aerosols for Potential Treatment of COVID-19
by Waiting Tai, Michael Yee Tak Chow, Rachel Yoon Kyung Chang, Patricia Tang, Igor Gonda, Robert B. MacArthur, Hak-Kim Chan and Philip Chi Lip Kwok
Pharmaceutics 2021, 13(8), 1260; https://doi.org/10.3390/pharmaceutics13081260 - 14 Aug 2021
Cited by 11 | Viewed by 7695
Abstract
The coronavirus disease 2019 (COVID-19) is an unprecedented pandemic that has severely impacted global public health and the economy. Hydroxychloroquine administered orally to COVID-19 patients was ineffective, but its antiviral and anti-inflammatory actions were observed in vitro. The lack of efficacy in vivo [...] Read more.
The coronavirus disease 2019 (COVID-19) is an unprecedented pandemic that has severely impacted global public health and the economy. Hydroxychloroquine administered orally to COVID-19 patients was ineffective, but its antiviral and anti-inflammatory actions were observed in vitro. The lack of efficacy in vivo could be due to the inefficiency of the oral route in attaining high drug concentration in the lungs. Delivering hydroxychloroquine by inhalation may be a promising alternative for direct targeting with minimal systemic exposure. This paper reports on the characterisation of isotonic, pH-neutral hydroxychloroquine sulphate (HCQS) solutions for nebulisation for COVID-19. They can be prepared, sterilised, and nebulised for testing as an investigational new drug for treating this infection. The 20, 50, and 100 mg/mL HCQS solutions were stable for at least 15 days without refrigeration when stored in darkness. They were atomised from Aerogen Solo Ultra vibrating mesh nebulisers (1 mL of each of the three concentrations and, in addition, 1.5 mL of 100 mg/mL) to form droplets having a median volumetric diameter of 4.3–5.2 µm, with about 50–60% of the aerosol by volume < 5 µm. The aerosol droplet size decreased (from 4.95 to 4.34 µm) with increasing drug concentration (from 20 to 100 mg/mL). As the drug concentration and liquid volume increased, the nebulisation duration increased from 3 to 11 min. The emitted doses ranged from 9.1 to 75.9 mg, depending on the concentration and volume nebulised. The HCQS solutions appear suitable for preclinical and clinical studies for potential COVID-19 treatment. Full article
(This article belongs to the Special Issue Inhaled Treatment of Respiratory Infections)
Show Figures

Figure 1

14 pages, 6042 KB  
Article
A Simple Electrostatic Precipitator for Trapping Virus Particles Spread via Droplet Transmission
by Koji Kakutani, Yoshinori Matsuda, Teruo Nonomura, Yoshihiro Takikawa, Takeshi Takami and Hideyoshi Toyoda
Int. J. Environ. Res. Public Health 2021, 18(9), 4934; https://doi.org/10.3390/ijerph18094934 - 6 May 2021
Cited by 19 | Viewed by 4641
Abstract
The purpose of this study was to develop a simple electrostatic apparatus to precipitate virus particles spread via droplet transmission, which is especially significant in the context of the recent coronavirus disease 2019 (COVID-19) pandemic. The bacteriophage φ6 of Pseudomonas syringae was used [...] Read more.
The purpose of this study was to develop a simple electrostatic apparatus to precipitate virus particles spread via droplet transmission, which is especially significant in the context of the recent coronavirus disease 2019 (COVID-19) pandemic. The bacteriophage φ6 of Pseudomonas syringae was used as a model of the COVID-19 virus because of its similar structure and safety in experiments. The apparatus consisted of a spiked, perforated stainless plate (S-PSP) linked to a direct-current voltage generator to supply negative charge to the spike tips and a vessel with water (G-water) linked to a ground line. The S-PSP and G-water surface were paralleled at a definite interval. Negative charge supplied to the spike tips positively polarised the G-water by electrostatic induction to form an electric field between them in which ionic wind and negative ions were generated. Bacteriophage-containing water was atomised with a nebuliser and introduced into the electric field. The mist particles were ionised by the negative ions and attracted to the opposite pole (G-water). This apparatus demonstrated a prominent ability to capture phage-containing mist particles of the same sizes as respiratory droplets and aerosols regardless of the phage concentration of the mist particles. The trapped phages were successfully sterilised using ozone bubbling. Thus, the present study provides an effective system for eliminating droplet transmission of viral pathogens from public spaces. Full article
Show Figures

Figure 1

13 pages, 2212 KB  
Review
PC945, a Novel Inhaled Antifungal Agent, for the Treatment of Respiratory Fungal Infections
by Alison Murray, Lindsey Cass, Kazuhiro Ito, Nicole Pagani, Darius Armstrong-James, Paras Dalal, Anna Reed and Pete Strong
J. Fungi 2020, 6(4), 373; https://doi.org/10.3390/jof6040373 - 17 Dec 2020
Cited by 31 | Viewed by 5905
Abstract
Disease due to pulmonary Aspergillus infection remains a significant unmet need, particularly in immunocompromised patients, patients in critical care and those with underlying chronic lung diseases. To date, treatment using inhaled antifungal agents has been limited to repurposing available systemic medicines. PC945 is [...] Read more.
Disease due to pulmonary Aspergillus infection remains a significant unmet need, particularly in immunocompromised patients, patients in critical care and those with underlying chronic lung diseases. To date, treatment using inhaled antifungal agents has been limited to repurposing available systemic medicines. PC945 is a novel triazole antifungal agent, a potent inhibitor of CYP51, purpose-designed to be administered via inhalation for high local lung concentrations and limited systemic exposure. In preclinical testing, PC945 is potent versus Aspergillus spp. and Candida spp. and showed two remarkable properties in preclinical studies, in vitro and in vivo. The antifungal effects against Aspergillus fumigatus accumulate on repeat dosing and improved efficacy has been demonstrated when PC945 is dosed in combination with systemic anti-fungal agents of multiple classes. Resistance to PC945 has been induced in Aspergillus fumigatus in vitro, resulting in a strain which remained susceptible to other antifungal triazoles. In healthy volunteers and asthmatics, nebulised PC945 was well tolerated, with limited systemic exposure and an apparently long lung residency time. In two lung transplant patients, PC945 treated an invasive pulmonary Aspergillus infection that had been unresponsive to multiple antifungal agents (systemic ± inhaled) without systemic side effects or detected drug–drug interactions. Full article
(This article belongs to the Special Issue Antifungal Agents Recently Approved or Under Development)
Show Figures

Figure 1

14 pages, 786 KB  
Review
A Review: The Prospect of Inhaled Insulin Therapy via Vibrating Mesh Technology to Treat Diabetes
by Seán M. Cunningham and David A. Tanner
Int. J. Environ. Res. Public Health 2020, 17(16), 5795; https://doi.org/10.3390/ijerph17165795 - 10 Aug 2020
Cited by 22 | Viewed by 6326
Abstract
Background: Inhaled insulin has proven to be viable and, in some aspects, a more effective alternative to subcutaneous insulin. Past and present insulin inhaler devices have not found clinical or commercial success. Insulin inhalers create a dry powder or soft mist insulin [...] Read more.
Background: Inhaled insulin has proven to be viable and, in some aspects, a more effective alternative to subcutaneous insulin. Past and present insulin inhaler devices have not found clinical or commercial success. Insulin inhalers create a dry powder or soft mist insulin aerosol, which does not provide the required uniform particle size or aerosol volume for deep lung deposition. Methods: The primary focus of this review is to investigate the potential treatment of diabetes with a wet insulin aerosol. Vibrating mesh nebulisers allow the passive inhalation of a fine wet mist aerosol for the administration of drugs to the pulmonary system in higher volumes than other small-volume nebulisers. Results: At present, there is a significant focus on vibrating mesh nebulisers from the pharmaceutical and biomedical industries for the systemic administration of pharmaceuticals for non-traditional applications such as vaccines or the treatment of diabetes. Systemic drug administration using vibrating mesh nebulisers leads to faster-acting pharmaceuticals with a reduction in drug latency. Conclusions: Systemic conditions such as diabetes, require the innovative development of custom vibrating mesh devices to provide the desired flow rates and droplet size for effective inhaled insulin administration. Full article
Show Figures

Figure 1

9 pages, 1159 KB  
Article
Pilot Study of Aerosolised Plus Intravenous Vancomycin in Mechanically Ventilated Patients with Methicillin-Resistant Staphylococcus Aureus Pneumonia
by Jun Yeun Cho, Hyung-Sook Kim, Hye-Joo Yang, Yeon Joo Lee, Jong Sun Park, Ho Il Yoon, Hong Bin Kim, Jae-Joon Yim, Jae-Ho Lee, Choon-Taek Lee and Young-Jae Cho
J. Clin. Med. 2020, 9(2), 476; https://doi.org/10.3390/jcm9020476 - 9 Feb 2020
Cited by 4 | Viewed by 3488
Abstract
Treatment of methicillin-resistant Staphylococcus aureus (MRSA) pneumonia in critically ill patients remains unsatisfactory. This pilot study aimed to evaluate the clinical outcomes of aerosolised vancomycin in addition to intravenous administration in this setting. This was a prospective, noncomparative, phase II trial. Patients receiving [...] Read more.
Treatment of methicillin-resistant Staphylococcus aureus (MRSA) pneumonia in critically ill patients remains unsatisfactory. This pilot study aimed to evaluate the clinical outcomes of aerosolised vancomycin in addition to intravenous administration in this setting. This was a prospective, noncomparative, phase II trial. Patients receiving mechanical ventilation for >48 h in intensive care units (ICUs) were screened; those receiving intravenous vancomycin for MRSA pneumonia were enrolled. Patients received aerosolised vancomycin (250 mg every 12 h for five days) via a vibrating mesh nebuliser. The primary outcome was treatment success (clinical cure or improvement) at the conclusion of antibiotic treatment. Vancomycin concentrations were measured in bronchoalveolar lavage fluid according to administration time. Twenty patients were enrolled (median age 75 years and 13 (65%) men; 18 (90%) cases with nosocomial pneumonia). Thirteen patients (65%) showed clinical cure or improvement. Microbiological eradication of MRSA was confirmed in 14 patients (70%). ICU and hospital mortality rates were 30% and 35%, respectively. Maximum aerosolised vancomycin concentration was observed 4–5 h after nebulising (98.75 ± 21.79 mcg/mL). No additional systemic adverse effects occurred following aerosol vancomycin treatment. Aerosolised vancomycin combination therapy may be an alternative treatment for patients with severe MRSA pneumonia receiving mechanical ventilation (ClinicalTrials.gov number, NCT01925066). Full article
(This article belongs to the Section Respiratory Medicine)