Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = portable PM sensing devices

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
48 pages, 6422 KB  
Review
Modern Trends and Recent Applications of Hyperspectral Imaging: A Review
by Ming-Fang Cheng, Arvind Mukundan, Riya Karmakar, Muhamed Adil Edavana Valappil, Jumana Jouhar and Hsiang-Chen Wang
Technologies 2025, 13(5), 170; https://doi.org/10.3390/technologies13050170 - 23 Apr 2025
Cited by 49 | Viewed by 17022
Abstract
Hyperspectral imaging (HSI) is an advanced imaging technique that captures detailed spectral information across multiple fields. This review explores its applications in counterfeit detection, remote sensing, agriculture, medical imaging, cancer detection, environmental monitoring, mining, mineralogy, and food processing, specifically highlighting significant achievements from [...] Read more.
Hyperspectral imaging (HSI) is an advanced imaging technique that captures detailed spectral information across multiple fields. This review explores its applications in counterfeit detection, remote sensing, agriculture, medical imaging, cancer detection, environmental monitoring, mining, mineralogy, and food processing, specifically highlighting significant achievements from the past five years, providing a timely update across several fields. It also presents a cross-disciplinary classification framework to systematically categorize applications in medical, agriculture, environment, and industry. In counterfeit detection, HSI identified fake currency with high accuracy in the 400–500 nm range and achieved a 99.03% F1-score for counterfeit alcohol detection. Remote sensing applications include hyperspectral satellites, which improve forest classification accuracy by 50%, and soil organic matter, with the prediction reaching R2 = 0.6. In agriculture, the HSI-TransUNet model achieved 86.05% accuracy for crop classification, and disease detection reached 98.09% accuracy. Medical imaging benefits from HSI’s non-invasive diagnostics, distinguishing skin cancer with 87% sensitivity and 88% specificity. In cancer detection, colorectal cancer identification reached 86% sensitivity and 95% specificity. Environmental applications include PM2.5 pollution detection with 85.93% accuracy and marine plastic waste detection with 70–80% accuracy. In food processing, egg freshness prediction achieved R2 = 91%, and pine nut classification reached 100% accuracy. Despite its advantages, HSI faces challenges like high costs and complex data processing. Advances in artificial intelligence and miniaturization are expected to improve accessibility and real-time applications. Future advancements are anticipated to concentrate on the integration of deep learning models for automated feature extraction and decision-making in hyperspectral imaging analysis. The development of lightweight, portable HSI devices will enable more on-site applications in agriculture, healthcare, and environmental monitoring. Moreover, real-time processing methods will enhance efficiency for field deployment. These improvements seek to enhance the accessibility, practicality, and efficacy of HSI in both industrial and clinical environments. Full article
Show Figures

Figure 1

10 pages, 3980 KB  
Article
Light Harvesting Nanoprobe for Trace Detection of Hg2+ in Water
by Aleksandr Chepak, Denis Balatskiy, Mikhail Tutov, Aleksandr Mironenko and Svetlana Bratskaya
Molecules 2023, 28(4), 1633; https://doi.org/10.3390/molecules28041633 - 8 Feb 2023
Cited by 4 | Viewed by 2433
Abstract
The continuously increasing flow of toxic heavy metals to the environment due to intensive industrial activity and tightening requirements with regard to the content of metal ions in drinking and discharged waters urges the development of affordable and sensitive devices to the field [...] Read more.
The continuously increasing flow of toxic heavy metals to the environment due to intensive industrial activity and tightening requirements with regard to the content of metal ions in drinking and discharged waters urges the development of affordable and sensitive devices to the field control of pollutants. Here, we report a new thiated Rhodamine-lactam probe for Hg2+ detection and demonstrate how its sensitivity can be increased via the incorporation of the probe molecules into the optically transparent siloxane-acrylate coatings on polymethyl methacrylate and, alternatively, into the water-dispersible light-harvesting FRET nanoparticles (NPs), in which dye cations are separated by fluorinated tetraphenylborate anions. We have shown that the optimization of the FRET NPs composition had allowed it to reach the antenna effect of ~300 and fabricate “off/on” sensor for Hg2+ ion determination in aqueous solutions with the detection limit of ~100 pM, which is far below the maximum permissible concentration (MPC) of mercury in drinking water recommended by the World Health Organization. Although this work is more proof-of-concept than a ready-to-use analytical procedure, the suggested approaches to fabrication of the FRET NPs based on the popular rhodamine-lactam platform can be used as a background for the development of low-cost portable sensing devices for the extra-laboratory determination of hazardous metal ions. Full article
(This article belongs to the Section Organic Chemistry)
Show Figures

Figure 1

15 pages, 3173 KB  
Article
Design of a Portable Microfluidic Platform for EGOT-Based in Liquid Biosensing
by Matteo Segantini, Matteo Parmeggiani, Alberto Ballesio, Gianluca Palmara, Francesca Frascella, Simone Luigi Marasso and Matteo Cocuzza
Sensors 2022, 22(3), 969; https://doi.org/10.3390/s22030969 - 26 Jan 2022
Cited by 12 | Viewed by 4231
Abstract
In biosensing applications, the exploitation of organic transistors gated via a liquid electrolyte has increased in the last years thanks to their enormous advantages in terms of sensitivity, low cost and power consumption. However, a practical aspect limiting the use of these devices [...] Read more.
In biosensing applications, the exploitation of organic transistors gated via a liquid electrolyte has increased in the last years thanks to their enormous advantages in terms of sensitivity, low cost and power consumption. However, a practical aspect limiting the use of these devices in real applications is the contamination of the organic material, which represents an obstacle for the realization of a portable sensing platform based on electrolyte-gated organic transistors (EGOTs). In this work, a novel contamination-free microfluidic platform allowing differential measurements is presented and validated through finite element modeling simulations. The proposed design allows the exposure of the sensing electrode without contaminating the EGOT device during the whole sensing tests protocol. Furthermore, the platform is exploited to perform the detection of bovine serum albumin (BSA) as a validation test for the introduced differential protocol, demonstrating the capability to detect BSA at 1 pM concentration. The lack of contamination and the differential measurements provided in this work can be the first steps towards the realization of a reliable EGOT-based portable sensing instrument. Full article
Show Figures

Graphical abstract

17 pages, 1874 KB  
Article
Demonstrating the Applicability of Smartwatches in PM2.5 Health Impact Assessment
by Ming-Chien Mark Tsou, Shih-Chun Candice Lung and Chih-Hui Cheng
Sensors 2021, 21(13), 4585; https://doi.org/10.3390/s21134585 - 4 Jul 2021
Cited by 10 | Viewed by 4611
Abstract
Smartwatches are being increasingly used in research to monitor heart rate (HR). However, it is debatable whether the data from smartwatches are of high enough quality to be applied in assessing the health impacts of air pollutants. The objective of this study was [...] Read more.
Smartwatches are being increasingly used in research to monitor heart rate (HR). However, it is debatable whether the data from smartwatches are of high enough quality to be applied in assessing the health impacts of air pollutants. The objective of this study was to assess whether smartwatches are useful complements to certified medical devices for assessing PM2.5 health impacts. Smartwatches and medical devices were used to measure HR for 7 and 2 days consecutively, respectively, for 49 subjects in 2020 in Taiwan. Their associations with PM2.5 from low-cost sensing devices were assessed. Good correlations in HR were found between smartwatches and certified medical devices (rs > 0.6, except for exercise, commuting, and worshipping). The health damage coefficients obtained from smartwatches (0.282% increase per 10 μg/m3 increase in PM2.5) showed the same direction, with a difference of only 8.74% in magnitude compared to those obtained from certified medical devices. Additionally, with large sample sizes, the health impacts during high-intensity activities were assessed. Our work demonstrates that smartwatches are useful complements to certified medical devices in PM2.5 health assessment, which can be replicated in developing countries. Full article
Show Figures

Figure 1

12 pages, 1973 KB  
Article
A Self-Calibrating IoT Portable Electrochemical Immunosensor for Serum Human Epididymis Protein 4 as a Tumor Biomarker for Ovarian Cancer
by Valentina Bianchi, Monica Mattarozzi, Marco Giannetto, Andrea Boni, Ilaria De Munari and Maria Careri
Sensors 2020, 20(7), 2016; https://doi.org/10.3390/s20072016 - 3 Apr 2020
Cited by 26 | Viewed by 4914
Abstract
Nowadays, analytical techniques are moving towards the development of smart biosensing strategies for the point-of-care accurate screening of disease biomarkers, such as human epididymis protein 4 (HE4), a recently discovered serum marker for early ovarian cancer diagnosis. In this context, the present work [...] Read more.
Nowadays, analytical techniques are moving towards the development of smart biosensing strategies for the point-of-care accurate screening of disease biomarkers, such as human epididymis protein 4 (HE4), a recently discovered serum marker for early ovarian cancer diagnosis. In this context, the present work represents the first implementation of a competitive enzyme-labelled magneto-immunoassay exploiting a homemade IoT Wi-Fi cloud-based portable potentiostat for differential pulse voltammetry readout. The electrochemical device was specifically designed to be capable of autonomous calibration and data processing, switching between calibration, and measurement modes: in particular, firstly, a baseline estimation algorithm is applied for correct peak computation, then calibration function is built by interpolating data with a four-parameter logistic function. The calibration function parameters are stored on the cloud for inverse prediction to determine the concentration of unknown samples. Interpolation function calibration and concentration evaluation are performed directly on-board, thus reducing the power consumption. The analytical device was validated in human serum, demonstrating good sensing performance for analysis of HE4 with detection and quantitation limits in human serum of 3.5 and 29.2 pM, respectively, reaching the sensitivity that is required for diagnostic purposes, with high potential for applications as portable and smart diagnostic tool for point-of-care testing. Full article
(This article belongs to the Special Issue Novel Electrochemical Biosensors for Clinical Assays)
Show Figures

Graphical abstract

Back to TopTop