Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (8)

Search Parameters:
Keywords = pulmonary atresia and intact ventricular septum

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 1616 KB  
Article
Echocardiographic Features and Clinical Outcomes of Functional vs. Anatomical Pulmonary Atresia with Intact Ventricular Septum in Neonates
by Yalun Qu, Shuang Yang, Yuefeng Cao, Jiachen Li, Zhongyi Han, Dong Wang, Yao Yang, Yongtao Wu and Qiang Wang
J. Cardiovasc. Dev. Dis. 2026, 13(2), 95; https://doi.org/10.3390/jcdd13020095 - 15 Feb 2026
Viewed by 1633
Abstract
(1) Background: Functional pulmonary atresia (FPA) and pulmonary atresia with intact ventricular septum (PA/IVS) are rare neonatal congenital heart diseases with similar early clinical manifestations but distinct pathophysiology and treatment strategies, making early and accurate differentiation clinically important. (2) Methods: This single-center retrospective [...] Read more.
(1) Background: Functional pulmonary atresia (FPA) and pulmonary atresia with intact ventricular septum (PA/IVS) are rare neonatal congenital heart diseases with similar early clinical manifestations but distinct pathophysiology and treatment strategies, making early and accurate differentiation clinically important. (2) Methods: This single-center retrospective study included 43 neonates diagnosed with FPA (n = 12) or PA/IVS (n = 31) between December 2016 and March 2025. Echocardiographic parameters and clinical data were compared between groups, and receiver operating characteristic curve analysis was performed to evaluate the usefulness of selected echocardiographic indices for differentiation in clinical practice. (3) Results: Compared with PA/IVS, neonates with FPA exhibited significantly larger right atrial area, relatively better preserved right ventricular development, larger patent ductus arteriosus diameter, and lower peak tricuspid regurgitation velocity. Several parameters, including right atrial area and the right-to-left ventricular ratio, demonstrated strong between-group discrimination in this cohort. Clinically, most FPA neonates were managed conservatively with favorable outcomes, whereas PA/IVS neonates required surgical intervention and experienced higher perioperative mortality. (4) Conclusions: FPA and PA/IVS differ significantly in right heart morphology, hemodynamic characteristics, and management strategies. A comprehensive multi-parameter echocardiographic evaluation demonstrated discriminatory ability in this cohort, facilitating appropriate treatment decisions and potentially helping to avoid unnecessary high-risk surgical interventions. Full article
Show Figures

Figure 1

18 pages, 3085 KB  
Article
Whole-Exome Sequencing Identifies Novel GATA5/6 Variants in Right-Sided Congenital Heart Defects
by Gloria K. E. Zodanu, John H. Hwang, Jordan Mudery, Carlos Sisniega, Xuedong Kang, Lee-Kai Wang, Alexander Barsegian, Reshma M. Biniwale, Ming-Sing Si, Nancy J. Halnon, UCLA Congenital Heart Defects-BioCore Faculty, Wayne W. Grody, Gary M. Satou, Glen S. Van Arsdell, Stanly F. Nelson and Marlin Touma
Int. J. Mol. Sci. 2025, 26(5), 2115; https://doi.org/10.3390/ijms26052115 - 27 Feb 2025
Cited by 2 | Viewed by 3112
Abstract
One out of every hundred live births present with congenital heart abnormalities caused by the aberrant development of the embryonic cardiovascular system. The conserved zinc finger transcription factor proteins, which include GATA binding protein 5 (GATA5) and GATA binding protein (GATA6) play important [...] Read more.
One out of every hundred live births present with congenital heart abnormalities caused by the aberrant development of the embryonic cardiovascular system. The conserved zinc finger transcription factor proteins, which include GATA binding protein 5 (GATA5) and GATA binding protein (GATA6) play important roles in embryonic development and their inactivation may result in congenital heart defects (CHDs). In this study, we performed genotypic–phenotypic analyses in two families affected by right-sided CHD diagnosed by echocardiography imaging. Proband A presented with pulmonary valve stenosis, and proband B presented with complex CHD involving the right heart structures. For variant detection, we employed whole-genome single-nucleotide polymorphism (SNP) microarray and family-based whole-exome sequencing (WES) studies. Proband A is a full-term infant who was admitted to the neonatal intensive care unit (NICU) at five days of life for pulmonary valve stenosis (PVS). Genomic studies revealed a normal SNP microarray; however, quad WES analysis identified a novel heterozygous [Chr20:g.61041597C>G (p.Arg237Pro)] variant in the GATA5 gene. Further analysis confirmed that the novel variant was inherited from the mother but was absent in the father and the maternal uncle with a history of heart murmur. Proband B was born prematurely at 35 weeks gestation with a prenatally diagnosed complex CHD. A postnatal evaluation revealed right-sided heart defects including pulmonary atresia with intact ventricular septum (PA/IVS), right ventricular hypoplasia, tricuspid valve hypoplasia, hypoplastic main and bilateral branch pulmonary arteries, and possible coronary sinusoids. Cardiac catheterization yielded anatomy and hemodynamics unfavorable to repair. Hence, heart transplantation was indicated. Upon genomic testing, a normal SNP microarray was observed, while trio WES analysis identified a novel heterozygous [Chr18:c.1757C>T (p.Pro586Leu)] variant in the GATA6 gene. This variant was inherited from the father, who carries a clinical diagnosis of tetralogy of Fallot. These findings provide new insights into novel GATA5/6 variants, elaborate on the genotypic and phenotypic association, and highlight the critical role of GATA5 and GATA6 transcription factors in a wide spectrum of right-sided CHDs. Full article
(This article belongs to the Special Issue Genetic Variations in Human Diseases: 2nd Edition)
Show Figures

Figure 1

21 pages, 21208 KB  
Review
Catheter-Based Fetal Cardiac Interventions
by Betul Yilmaz Furtun and Shaine Alaine Morris
J. Cardiovasc. Dev. Dis. 2024, 11(6), 167; https://doi.org/10.3390/jcdd11060167 - 29 May 2024
Cited by 10 | Viewed by 4869
Abstract
Fetal cardiac intervention (FCI) is an emerging and rapidly advancing group of interventions designed to improve outcomes for fetuses with cardiovascular disease. Currently, FCI is comprised of pharmacologic therapies (e.g., trans-placental antiarrhythmics for fetal arrhythmia), open surgical procedures (e.g., surgical resection of pericardial [...] Read more.
Fetal cardiac intervention (FCI) is an emerging and rapidly advancing group of interventions designed to improve outcomes for fetuses with cardiovascular disease. Currently, FCI is comprised of pharmacologic therapies (e.g., trans-placental antiarrhythmics for fetal arrhythmia), open surgical procedures (e.g., surgical resection of pericardial teratoma), and catheter-based procedures (e.g., fetal aortic valvuloplasty for aortic stenosis). This review focuses on the rationale, criteria for inclusion, technical details, and current outcomes of the three most frequently performed catheter-based FCI procedures: (1) aortic valvuloplasty for critical aortic stenosis (AS) associated with evolving hypoplastic left heart syndrome (HLHS), (2) atrial septal intervention for HLHS with severely restrictive or intact atrial septum (R/IAS), and (3) pulmonary valvuloplasty for pulmonary atresia with intact ventricular septum (PA/IVS). Full article
Show Figures

Figure 1

8 pages, 2382 KB  
Case Report
Brugada Syndrome and Pulmonary Atresia with Intact Interventricular Septum: Fortuitous Finding or New Genetic Connection?
by Miguel Fogaça-da-Mata, Estefanía Martínez-Barrios, Lorenzo Jiménez-Montañés, José Cruzalegui, Fredy Chipa-Ccasani, Andrea Greco, Sergi Cesar, Núria Díez-Escuté, Patricia Cerralbo, Irene Zschaeck, Marcos Clavero Adell, Ariadna Ayerza-Casas, Daniel Palanca-Arias, Marta López, Oscar Campuzano, Josep Brugada and Georgia Sarquella-Brugada
Genes 2024, 15(5), 638; https://doi.org/10.3390/genes15050638 - 17 May 2024
Cited by 1 | Viewed by 2070
Abstract
Brugada syndrome is a rare arrhythmogenic syndrome associated mainly with pathogenic variants in the SCN5A gene. Right ventricle outflow tract fibrosis has been reported in some cases of patients diagnosed with Brugada syndrome. Pulmonary atresia with an intact ventricular septum is characterized by [...] Read more.
Brugada syndrome is a rare arrhythmogenic syndrome associated mainly with pathogenic variants in the SCN5A gene. Right ventricle outflow tract fibrosis has been reported in some cases of patients diagnosed with Brugada syndrome. Pulmonary atresia with an intact ventricular septum is characterized by the lack of a functional pulmonary valve, due to the underdevelopment of the right ventricle outflow tract. We report, for the first time, a 4-year-old boy with pulmonary atresia with an intact ventricular septum who harbored a pathogenic de novo variant in SCN5A, and the ajmaline test unmasked a type-1 Brugada pattern. We suggest that deleterious variants in the SCN5A gene could be implicated in pulmonary atresia with an intact ventricular septum embryogenesis, leading to overlapping phenotypes. Full article
(This article belongs to the Special Issue Genetics of Congenital Heart Diseases)
Show Figures

Figure 1

11 pages, 1659 KB  
Review
Echocardiographic Parameters for Risk Prediction in Borderline Right Ventricle: Review with Special Emphasis on Pulmonary Atresia with Intact Ventricular Septum and Critical Pulmonary Stenosis
by Massimiliano Cantinotti, Colin Joseph McMahon, Pietro Marchese, Martin Köstenberger, Marco Scalese, Eliana Franchi, Giuseppe Santoro, Nadia Assanta, Xander Jacquemyn, Shelby Kutty and Raffaele Giordano
J. Clin. Med. 2023, 12(14), 4599; https://doi.org/10.3390/jcm12144599 - 10 Jul 2023
Cited by 6 | Viewed by 3561
Abstract
The aim of the present review is to highlight the strengths and limitations of echocardiographic parameters and scores employed to predict favorable outcome in complex congenital heart diseases (CHDs) with borderline right ventricle (RV), with a focus on pulmonary atresia with intact ventricular [...] Read more.
The aim of the present review is to highlight the strengths and limitations of echocardiographic parameters and scores employed to predict favorable outcome in complex congenital heart diseases (CHDs) with borderline right ventricle (RV), with a focus on pulmonary atresia with intact ventricular septum and critical pulmonary stenosis (PAIVS/CPS). A systematic search in the National Library of Medicine using Medical Subject Headings and free-text terms including echocardiography, CHD, and scores, was performed. The search was refined by adding keywords “PAIVS/CPS”, Ebstein’s anomaly, and unbalanced atrioventricular septal defect with left dominance. A total of 22 studies were selected for final analysis; 12 of them were focused on parameters to predict biventricular repair (BVR)/pulmonary blood flow augmentation in PAIVS/CPS. All of these studies presented numerical (the limited sample size) and methodological limitations (retrospective design, poor definition of inclusion/exclusion criteria, variability in the definition of outcomes, differences in adopted surgical and interventional strategies). There was heterogeneity in the echocardiographic parameters employed and cut-off values proposed, with difficultly in establishing which one should be recommended. Easy scores such as TV/MV (tricuspid/mitral valve) and RV/LV (right/left ventricle) ratios were proven to have a good prognostic accuracy; however, the data were very limited (only two studies with <40 subjects). In larger studies, RV end-diastolic area and a higher degree of tricuspid regurgitation were also proven as accurate predictors of successful BVR. These measures, however, may be either operator and/or load/pressure dependent. TV Z-scores have been proposed by several authors, but old and heterogenous nomograms sources have been employed, thus producing discordant results. In summary, we provide a review of the currently available echocardiographic parameters for risk prediction in CHDs with a diminutive RV that may serve as a guide for use in clinical practice. Full article
(This article belongs to the Special Issue Clinical Research Advances in Congenital Heart Disease)
Show Figures

Figure 1

12 pages, 404 KB  
Article
Fetal Cardiac Interventions—Are They Safe for the Mothers?
by Beata Rebizant, Adam Koleśnik, Agnieszka Grzyb, Katarzyna Chaberek, Agnieszka Sękowska, Jacek Witwicki, Joanna Szymkiewicz-Dangel and Marzena Dębska
J. Clin. Med. 2021, 10(4), 851; https://doi.org/10.3390/jcm10040851 - 19 Feb 2021
Cited by 17 | Viewed by 3806
Abstract
The aim of fetal cardiac interventions (FCI), as other prenatal therapeutic procedures, is to bring benefit to the fetus. However, the safety of the mother is of utmost importance. The objective of our study was to evaluate the impact of FCI on maternal [...] Read more.
The aim of fetal cardiac interventions (FCI), as other prenatal therapeutic procedures, is to bring benefit to the fetus. However, the safety of the mother is of utmost importance. The objective of our study was to evaluate the impact of FCI on maternal condition, course of pregnancy, and delivery. 113 mothers underwent intrauterine treatment of their fetuses with critical heart defects. 128 percutaneous ultrasound-guided FCI were performed and analyzed. The patients were divided into four groups according to the type of FCI: balloon aortic valvuloplasty (fBAV), balloon pulmonary valvuloplasty (fBPV), interatrial stent placement (IAS), and balloon atrioseptoplasty (BAS). Various factors: maternal parameters, perioperative data, and pregnancy complications, were analyzed. There was only one major complication—procedure-related placental abruption (without need for blood products transfusion). There were no cases of: procedure-related preterm prelabor rupture of membranes (pPROM), chorioamnionitis, wound infection, and anesthesia associated complications. Tocolysis was only necessary only in two cases, and it was effective in both. None of the patients required intensive care unit admission. The procedure was effective in treating polyhydramnios associated with fetal heart failure in six out of nine cases. Deliveries occurred at term in 89%, 54% were vaginal. The results showed that FCI had a negligible impact on a further course of pregnancy and delivery. Full article
(This article belongs to the Section Obstetrics & Gynecology)
Show Figures

Figure 1

15 pages, 4028 KB  
Article
Fetal Cardiac Interventions—Polish Experience from “Zero” to the Third World Largest Program
by Marzena Debska, Adam Kolesnik, Beata Rebizant, Agnieszka Sekowska, Agnieszka Grzyb, Katarzyna Chaberek, Jacek Witwicki, Romuald Debski and Joanna Dangel
J. Clin. Med. 2020, 9(9), 2888; https://doi.org/10.3390/jcm9092888 - 7 Sep 2020
Cited by 22 | Viewed by 4762
Abstract
This article presents the technical aspects of the Polish fetal cardiac interventions (FCI) program, including preparation of the team and modifications in the technique of the procedure that aim to increase its safety for the mother and the fetus. Over 9 years, 128 [...] Read more.
This article presents the technical aspects of the Polish fetal cardiac interventions (FCI) program, including preparation of the team and modifications in the technique of the procedure that aim to increase its safety for the mother and the fetus. Over 9 years, 128 FCI in 113 fetuses have been performed: 94 balloon aortic valvuloplasties (fBAV), 14 balloon atrioseptoplasties (fBAS) with stent (BAS+), 5 balloon atrioseptoplasties without stent placement (BAS−), and 15 fetal pulmonary valvuloplasties (fBPS). The technical success rate ranged from 80% (BAS−) to 89% (fBAV), while the procedure-related death rate (defined as death within 72 hours following the procedure) ranged from 7% (fBAV and fBPV) to 20% (BAS). There were 98 live births after all FCI (3 pregnancies continue). Median gestational age at delivery was 39 weeks in our center and 38 weeks in other centers. Full article
(This article belongs to the Section Obstetrics & Gynecology)
Show Figures

Figure 1

31 pages, 20636 KB  
Review
Management of Congenital Heart Disease: State of the Art—Part II—Cyanotic Heart Defects
by P. Syamasundar Rao
Children 2019, 6(4), 54; https://doi.org/10.3390/children6040054 - 4 Apr 2019
Cited by 44 | Viewed by 22917
Abstract
In this review management of the most common cyanotic congenital heart defects (CHDs) was discussed; the management of acyanotic CHD was reviewed in Part I of this series. While the need for intervention in acyanotic CHD is by and large determined by the [...] Read more.
In this review management of the most common cyanotic congenital heart defects (CHDs) was discussed; the management of acyanotic CHD was reviewed in Part I of this series. While the need for intervention in acyanotic CHD is by and large determined by the severity of the lesion, most cyanotic CHDs require intervention, mostly by surgery. Different types of tetralogy of Fallot require different types of total surgical corrective procedures, and some may require initial palliation, mainly by modified Blalock–Taussig shunts. Babies with transposition of the great arteries with an intact ventricular septum as well as those with ventricular septal defects (VSD) need an arterial switch (Jatene) procedure while those with both VSD and pulmonary stenosis should be addressed by Rastelli procedure. These procedures may need to be preceded by prostaglandin infusion and/or balloon atrial septostomy in some babies. Infants with tricuspid atresia require initial palliation either with a modified Blalock–Taussig shunt or banding of the pulmonary artery and subsequent staged Fontan (bidirectional Glenn and fenestrated Fontan with extra-cardiac conduit). Neonates with total anomalous pulmonary venous connection are managed by anastomosis of the common pulmonary vein with the left atrium either electively in non-obstructed types or as an emergency procedure in the obstructed types. Babies with truncus arteriosus are treated by surgical closure of VSD along with right ventricle to pulmonary artery conduit. The other defects, namely, hypoplastic left heart syndrome, pulmonary atresia with intact ventricular septum, double-outlet right ventricle, double-inlet left ventricle and univentricular hearts largely require multistage surgical correction. The currently existing medical, trans-catheter and surgical techniques to manage cyanotic CHD are safe and effective and can be performed at a relatively low risk. Full article
Show Figures

Figure 1

Back to TopTop