Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (880)

Search Parameters:
Keywords = refractive index sensing

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
24 pages, 1497 KiB  
Article
Pulsed CO2 Laser-Fabricated Cascades of Double Resonance Long Period Gratings for Sensing Applications
by Tinko Eftimov, Sanaz Shoar Ghaffari, Georgi Dyankov, Veselin Vladev and Alla Arapova
Micromachines 2025, 16(8), 959; https://doi.org/10.3390/mi16080959 - 20 Aug 2025
Viewed by 101
Abstract
We present a detailed theoretical and experimental study of cascaded double resonance long period gratings (C DR LPGs) for fabricated sensing applications. The matrix description of cascaded LPGs is presented, and several important particular cases are considered related to the regular and turn [...] Read more.
We present a detailed theoretical and experimental study of cascaded double resonance long period gratings (C DR LPGs) for fabricated sensing applications. The matrix description of cascaded LPGs is presented, and several important particular cases are considered related to the regular and turn around point (TAP) gratings. A pulsed CO2 laser was used to fabricate ordinary and cascaded DR LPGs in a photosensitive optical fiber. The responses of the fabricated C DR LPGs to surrounding refractive index (SRI) temperature as well to longitudinal strain have been studied. A statistical comparison of the SRI sensitivities of ordinary and cascaded DR LPGs is presented to outline the capabilities and advantages of cascaded DR gratings. It was experimentally established that the temperature dependence of the wavelength split at the TAP follows a logarithmic dependence and the sensitivity to temperature is inversely proportional to the temperature itself. We evaluate the temperature stability needed for SRI-based sensing application and the importance of fine-tuning to the operational point slightly after the TAP to ensure maximum sensitivity of the sensor. Full article
11 pages, 1072 KiB  
Article
Design and Characteristic Simulation of Polarization-Maintaining Anti-Resonant Hollow-Core Fiber for 2.79 μm Er, Cr: YSGG Laser Transmission
by Lei Huang and Yinze Wang
Optics 2025, 6(3), 37; https://doi.org/10.3390/opt6030037 - 14 Aug 2025
Viewed by 136
Abstract
Anti-resonant hollow-core fibers have exhibited excellent performance in applications such as high-power pulse transmission, network communication, space exploration, and precise sensing. Employing anti-resonant hollow-core fibers instead of light guiding arms for transmitting laser energy at the 2.79 μm band can significantly enhance the [...] Read more.
Anti-resonant hollow-core fibers have exhibited excellent performance in applications such as high-power pulse transmission, network communication, space exploration, and precise sensing. Employing anti-resonant hollow-core fibers instead of light guiding arms for transmitting laser energy at the 2.79 μm band can significantly enhance the flexibility of medical laser handles, reduce system complexity, and increase laser transmission efficiency. Nevertheless, common anti-resonant hollow-core fibers do not have the ability to maintain the polarization state of light during laser transmission, which greatly affects their practical applications. In this paper, we propose a polarization-maintaining anti-resonant hollow-core fiber applicable for transmission at the mid-infrared 2.79 μm band. This fiber features a symmetrical geometric structure and an asymmetric refractive index cladding composed of quartz and a type of mid-infrared glass with a higher refractive index. Through optimizing the fiber structure at the wavelength scale, single-polarization transmission can be achieved at the 2.79 μm wavelength, with a polarization extinction ratio exceeding 1.01 × 105, indicating its stable polarization-maintaining performance. Simultaneously, it possesses low-loss transmission characteristics, with the loss in the x-polarized fundamental mode being less than 9.8 × 10−3 dB/m at the 2.79 µm wavelength. This polarization-maintaining anti-resonant hollow-core fiber provides a more reliable option for the light guiding system of the 2.79 μm Er; Cr: YSGG laser therapy device. Full article
Show Figures

Figure 1

12 pages, 1331 KiB  
Proceeding Paper
Tailoring the Optical and Sensing Properties of Sol–Gel Niobia Coatings via Doping with Silica and Noble Metal Nanoparticles
by Tsvetanka Babeva, Venelin Pavlov, Georgi Zlatinov, Biliana Georgieva, Penka Terziyska, Gergana Alexieva, Katerina Lazarova and Rosen Georgiev
Eng. Proc. 2025, 105(1), 4; https://doi.org/10.3390/engproc2025105004 - 14 Aug 2025
Viewed by 232
Abstract
Nb2O5 (niobia) coatings were prepared by spin coating of niobium sol, synthesized using niobium chloride as the precursor and ethanol and water as solvents, followed by high-temperature annealing. Doping of the films was achieved by incorporating commercially available SiO2 [...] Read more.
Nb2O5 (niobia) coatings were prepared by spin coating of niobium sol, synthesized using niobium chloride as the precursor and ethanol and water as solvents, followed by high-temperature annealing. Doping of the films was achieved by incorporating commercially available SiO2 (Ludox) and noble metal nanoparticles (NPs) into the sol prior to its deposition. Various sizes of Pt (5 and 30 nm), Ag (10, 20, and 40 nm), and Au (5, 10, and 20 nm) NPs were used to enhance sensing behavior of coatings. After annealing, films were subjected to chemical etching to remove the silica phase. This process generated porosity within the films, which in turn enabled the tailoring of both their optical and sensing properties. It was demonstrated that both the type and size of the incorporated nanoparticles significantly influenced the sensing behavior. The most effective enhancement was observed with the addition of 10 nm AuNPs. Optical characterization indicated that 10 nm AuNPs had a minimal effect on the optical properties. In contrast, doping with 20 nm AuNPs led to a reduction in the refractive index and an increase in Urbach energy. No significant alteration in the optical band gap due to doping was observed. Full article
Show Figures

Figure 1

12 pages, 2195 KiB  
Article
A Refractive Index Sensor Based on Spectral Interrogation of a Long Tapered Side-Hole Optical Fiber
by Rafał A. Kosturek, Michał Dudek and Leszek R. Jaroszewicz
Sensors 2025, 25(16), 4916; https://doi.org/10.3390/s25164916 - 9 Aug 2025
Viewed by 351
Abstract
This article describes an external refractive index (RI) sensor based on a spectral analysis of the light transmission through a long tapered side-hole optical fiber (S-H OF). A section of the S-H OF was fusion-spliced with SMFs at both ends and connected to [...] Read more.
This article describes an external refractive index (RI) sensor based on a spectral analysis of the light transmission through a long tapered side-hole optical fiber (S-H OF). A section of the S-H OF was fusion-spliced with SMFs at both ends and connected to a supercontinuum source at the input and an optical spectrum analyzer (OSA) at the output. To investigate the effect of the external RI on the spectral characteristics, immersion liquids with refractive indices in the ranges of 1.32–1.35 and 1.37–1.42, with increments of 0.01, were used. Power loss measurements were carried out for each liquid in two wavelength ranges: 600–1200 nm and 1200–1800 nm. The highest sensitivity obtained in this study was 622 ± 11 nm/RIU in the near-infrared region. This result highlights the suitability of longtapered S-H OFs for spectral-interrogation-based RI sensing, offering a promising yet simpler alternative to more complex interferometric or plasmonic configurations. Full article
(This article belongs to the Special Issue Fiber Optical Sensors and Biosensors)
Show Figures

Figure 1

19 pages, 3043 KiB  
Article
Enhancing Sensitivity of Commercial Gold Nanoparticle-Based Lateral Flow Assays: A Comparative Study of Colorimetric and Photothermal Approaches
by Jully Blackshare, Hansel A. Mina, Amanda J. Deering, Bartek Rajwa, J. Paul Robinson and Euiwon Bae
Sensors 2025, 25(16), 4904; https://doi.org/10.3390/s25164904 - 8 Aug 2025
Viewed by 362
Abstract
Lateral flow assays (LFAs) are extensively utilized in point-of-care diagnostics due to their affordability, simplicity, and rapid time-to-results. However, their low sensitivity remains a significant limitation, particularly for detecting foodborne pathogens at concentrations below regulatory thresholds. This study evaluated two distinct sensing modalities—photothermal [...] Read more.
Lateral flow assays (LFAs) are extensively utilized in point-of-care diagnostics due to their affordability, simplicity, and rapid time-to-results. However, their low sensitivity remains a significant limitation, particularly for detecting foodborne pathogens at concentrations below regulatory thresholds. This study evaluated two distinct sensing modalities—photothermal speckle imaging and colorimetric line intensity analysis—for their potential to enhance the sensitivity of commercially available LFAs. Photothermal imaging quantified refractive index shifts induced by plasmonic heating of gold nanoparticles, while colorimetric analysis used smartphone-acquired images processed with machine learning. The photothermal method achieved a limit of detection (LOD) of 2.13 × 105 CFU/mL, while the colorimetric approach, using a logistic regression model with LASSO regularization, achieved an LOD of 105 CFU/mL. While both approaches demonstrated detection thresholds comparable to traditional visual interpretation, the colorimetric method provided an added advantage by enabling quantitative prediction of bacterial concentration through regression modeling. With further optimization of each sensing method, these findings demonstrate the feasibility of improving unmodified commercial LFAs through optical and computational enhancements, offering a promising pathway toward the development of portable biosensing systems for real-time food safety monitoring. Full article
(This article belongs to the Special Issue Feature Papers in Optical Sensors 2025)
Show Figures

Figure 1

16 pages, 25225 KiB  
Article
Theory Design of a Virtual Polarizer with Multiscale and Multi-Biomass Sensing
by Chuanqi Wu and Haifeng Zhang
Biosensors 2025, 15(8), 516; https://doi.org/10.3390/bios15080516 - 8 Aug 2025
Viewed by 185
Abstract
Recently, more and more attention has been paid to human health with the rapid development of society. A designed virtual polarizer (VP) can realize multiscale and multi-biomass sensing, including temperature, cancerous cells, and COVID-19. Based on coherent perfect polarization conversion, a certain polarization [...] Read more.
Recently, more and more attention has been paid to human health with the rapid development of society. A designed virtual polarizer (VP) can realize multiscale and multi-biomass sensing, including temperature, cancerous cells, and COVID-19. Based on coherent perfect polarization conversion, a certain polarization conversion can be fulfilled within 1.72~2.14 THz. Then, through observing the displacement of a perfect matching point (PMP), variations in temperature can be accurately determined, covering from 299 K to 315 K, with a sensitivity (S) of 0.0198 THz/K. Moreover, a sharp coherent perfect absorption (CPA) peak generated from the VP can be employed for the detection of cancerous cells and COVID-19. The refractive index (RI) detection range of cancerous cells is from 1.36 RIU to 1.41 RIU with the sensitivity being −4.45881 THz/RIU. The average quality factor (Q), figure of merit (FOM), and detection limit (DL) are 825.36, 241.11 RIU−1, and −36.83 dB. For the COVID-19 solution concentration (SC) from 0 mM to 525 mM, by mapping SC to RI, the RI sensing range is 1.344 RIU–1.355 RIU with the S being −5.03467 THz/RIU. The relevant Q, FOM, and DL are 760.85, 244.94 RIU−1, and −36.89 dB. Based on two strategies of PMP and CPA, the proposed VP is capable of multiscale and multi-biomass sensing with excellent detection performance, providing a new detection method for biosensing. Full article
(This article belongs to the Special Issue Advanced Optics and Photonics in Biosensing Applications)
Show Figures

Figure 1

12 pages, 1829 KiB  
Article
Flexible Color Filter Using Lithium Niobate Metamaterial with Ultrahigh Purity and Brightness Characteristics
by Siqiang Zhao, Daoye Zheng, Yunche Zhu, Shuyan Zou and Yu-Sheng Lin
Photonics 2025, 12(8), 768; https://doi.org/10.3390/photonics12080768 - 30 Jul 2025
Viewed by 353
Abstract
We propose a simulation-based design for a flexible color filter (FCF) using a lithium niobate metamaterial (LNM) to investigate its color filtering potential. The FCF is composed of three periodically arranged half-ellipse LN arrays on a polydimethylsiloxane (PDMS) substrate, denoted as LNM-1, LNM-2, [...] Read more.
We propose a simulation-based design for a flexible color filter (FCF) using a lithium niobate metamaterial (LNM) to investigate its color filtering potential. The FCF is composed of three periodically arranged half-ellipse LN arrays on a polydimethylsiloxane (PDMS) substrate, denoted as LNM-1, LNM-2, and LNM-3. The electromagnetic responses of the FCF can be controlled by adjusting the periods of the LNMs. Our simulations predict high-quality (Q) factors in transmission spectra, ranging from 100 to 200 for LNM-1, 290 to 360 for LNM-2, and 140 to 300 for LNM-3. When the FCF is exposed to the surrounding environments with different refractive indexes, it exhibits a theoretical figure of merit (FOM) up to 900 RIU−1 and a sensitivity reaching 130 nm/RIU. The electromagnetic field distributions reveal strong confinement within the LNM nanostructures, confirming an efficient light–matter interaction. These results indicate that the proposed LNM-based FCF presents a promising design concept for high-performance color sensing and filtering applications. Full article
(This article belongs to the Special Issue Photonics Metamaterials: Processing and Applications)
Show Figures

Figure 1

16 pages, 2223 KiB  
Article
Plasmonic Sensing Design for Measuring the Na+/K+ Concentration in an Electrolyte Solution Based on the Simulation of Optical Principles
by Hongfu Chen, Shubin Yan, Yi Sun, Youbo Hu, Taiquan Wu and Yuntang Li
Photonics 2025, 12(8), 758; https://doi.org/10.3390/photonics12080758 - 28 Jul 2025
Viewed by 275
Abstract
Based on the theory of optical sensing, we propose a high-precision plasmonic refractive index nanosensor, which consists of a symmetric rectangular waveguide and a circular ring containing a rectangular cavity. The designed novel tunable micro-resonant circular cavity filter based on surface plasmon excitations [...] Read more.
Based on the theory of optical sensing, we propose a high-precision plasmonic refractive index nanosensor, which consists of a symmetric rectangular waveguide and a circular ring containing a rectangular cavity. The designed novel tunable micro-resonant circular cavity filter based on surface plasmon excitations is able to confine light to sub-wavelength dimensions. The data show that different geometrical factors have different effects on sensing, with the geometry of the rectangular cavity and the radius of the circular ring being the key factors affecting the Fano resonance. Furthermore, the resonance bifurcation enables the structure to achieve a tunable dual Fano resonance system. The structure was tuned to obtain optimal sensitivity (S) and figure of merit values up to 3066 nm/RIU and 78. The designed structure has excellent sensing performance with sensitivities of 0.4767 nm·(mg/dL1) and 0.6 nm·(mg/dL1) in detecting Na+ and K+ concentrations in the electrolyte solution, respectively, and can be easily achieved by the spectrometer. The wavelength accuracy of 0.001 nm can be easily achieved by a spectrum analyzer, which has a broad application prospect in the field of optical integration. Full article
Show Figures

Figure 1

16 pages, 2734 KiB  
Article
Quantitative Evaluation of Optical Clearing Agent Performance Based on Multilayer Monte Carlo and Diffusion Modeling
by Lu Fu, Changlun Hou, Dongbiao Zhang, Zhen Shi, Jufeng Zhao and Guangmang Cui
Photonics 2025, 12(8), 751; https://doi.org/10.3390/photonics12080751 - 25 Jul 2025
Viewed by 389
Abstract
Optical clearing agents (OCAs) offer a promising approach to enhance skin transparency by reducing scattering and improving photon transmission, which is critical for non-invasive optical diagnostics such as glucose sensing and vascular imaging. However, the complex multilayered structure of skin and anatomical variability [...] Read more.
Optical clearing agents (OCAs) offer a promising approach to enhance skin transparency by reducing scattering and improving photon transmission, which is critical for non-invasive optical diagnostics such as glucose sensing and vascular imaging. However, the complex multilayered structure of skin and anatomical variability across different regions pose challenges for accurately evaluating OCA performance. In this study, we developed a multilayer Monte Carlo (MC) simulation model integrated with a depth- and time-resolved diffusion model based on Fick’s law to quantitatively assess the combined effects of OCA penetration depth and refractive index change on optical clearing. The model incorporates realistic skin parameters, including variable stratum corneum thicknesses, and was validated through in vivo experiments using glycerol and glucose at different concentrations. Both the simulation and experimental results demonstrate that increased stratum corneum thickness significantly reduces blood absorption of light and lowers the clearing efficiency of OCAs. The primary influence of stratum corneum thickness lies in requiring a greater degree of refractive index matching rather than necessitating a deeper OCA penetration depth to achieve effective optical clearing. These findings underscore the importance of considering regional skin differences when selecting OCAs and designing treatment protocols. This work provides quantitative insights into the interaction between tissue structure and optical response, supporting improved application strategies in clinical diagnostics. Full article
(This article belongs to the Section Biophotonics and Biomedical Optics)
Show Figures

Figure 1

15 pages, 2929 KiB  
Article
Graphene-Loaded LiNbO3 Directional Coupler: Characteristics and Potential Applications
by Yifan Liu, Fei Lu, Hui Hu, Haoyang Du, Yan Liu and Yao Wei
Nanomaterials 2025, 15(14), 1116; https://doi.org/10.3390/nano15141116 - 18 Jul 2025
Viewed by 376
Abstract
This study explores the impact of graphene integration on lithium niobate (LiNbO3, LN) ridge waveguides and directional couplers, focusing on coupling efficiency, polarization-dependent light absorption, and temperature sensitivity. Experimental and simulation results reveal that graphene loading significantly alters the effective mode [...] Read more.
This study explores the impact of graphene integration on lithium niobate (LiNbO3, LN) ridge waveguides and directional couplers, focusing on coupling efficiency, polarization-dependent light absorption, and temperature sensitivity. Experimental and simulation results reveal that graphene loading significantly alters the effective mode refractive index and enhances waveguide coupling, enabling precise control over light transmission and power distribution. The temperature-dependent behavior of graphene–LN structures demonstrates strong thermal sensitivity, with notable changes in output power ratios between cross and through ports under varying temperatures. These findings highlight the potential of graphene–LN hybrid devices for compact, high-performance photonic circuits and temperature sensing applications. This study provides valuable insights into the design of advanced integrated photonic systems, paving the way for innovations in optical communication, sensing, and quantum technologies. Full article
Show Figures

Figure 1

36 pages, 8164 KiB  
Review
Technology Landscape Review of In-Sensor Photonic Intelligence: From Optical Sensors to Smart Devices
by Hong Zhou, Dongxiao Li and Chengkuo Lee
AI Sens. 2025, 1(1), 5; https://doi.org/10.3390/aisens1010005 - 14 Jul 2025
Cited by 1 | Viewed by 1650
Abstract
Optical sensors have undergone significant evolution, transitioning from discrete optical microsystems toward sophisticated photonic integrated circuits (PICs) that leverage artificial intelligence (AI) for enhanced functionality. This review systematically explores the integration of optical sensing technologies with AI, charting the advancement from conventional optical [...] Read more.
Optical sensors have undergone significant evolution, transitioning from discrete optical microsystems toward sophisticated photonic integrated circuits (PICs) that leverage artificial intelligence (AI) for enhanced functionality. This review systematically explores the integration of optical sensing technologies with AI, charting the advancement from conventional optical microsystems to AI-driven smart devices. First, we examine classical optical sensing methodologies, including refractive index sensing, surface-enhanced infrared absorption (SEIRA), surface-enhanced Raman spectroscopy (SERS), surface plasmon-enhanced chiral spectroscopy, and surface-enhanced fluorescence (SEF) spectroscopy, highlighting their principles, capabilities, and limitations. Subsequently, we analyze the architecture of PIC-based sensing platforms, emphasizing their miniaturization, scalability, and real-time detection performance. This review then introduces the emerging paradigm of in-sensor computing, where AI algorithms are integrated directly within photonic devices, enabling real-time data processing, decision making, and enhanced system autonomy. Finally, we offer a comprehensive outlook on current technological challenges and future research directions, addressing integration complexity, material compatibility, and data processing bottlenecks. This review provides timely insights into the transformative potential of AI-enhanced PIC sensors, setting the stage for future innovations in autonomous, intelligent sensing applications. Full article
Show Figures

Figure 1

11 pages, 2799 KiB  
Article
Development of LPFG-Based Seawater Concentration Monitoring Sensors Packaged by BFRP
by Zhe Zhang, Tongchun Qin, Yuping Bao and Jianping He
Micromachines 2025, 16(7), 810; https://doi.org/10.3390/mi16070810 - 14 Jul 2025
Viewed by 341
Abstract
Leveraging the sensitivity of long-period fiber grating (LPFG) to changes in the environmental refractive index, an LPFG-based seawater concentration monitoring sensor is proposed. Considering the highly saltine and alkali characteristics of the sensor’s operating environment, the proposed sensor is packaged by basalt fiber-reinforced [...] Read more.
Leveraging the sensitivity of long-period fiber grating (LPFG) to changes in the environmental refractive index, an LPFG-based seawater concentration monitoring sensor is proposed. Considering the highly saltine and alkali characteristics of the sensor’s operating environment, the proposed sensor is packaged by basalt fiber-reinforced polymer (BFRP), and the sensor’s sensitivities were studied by sodium chloride and calcium chloride solution concentration experiments and one real-time sodium chloride solution concentration monitoring experiment. The test results show the wavelength of LPFG, a 3 dB bandwidth and a peak loss of LPFG’s spectrogram change with changes in the concentration of sodium chloride or calcium chloride solutions, but only the wavelength has a good linear relationship with the change in solution concentration, and the sensing coefficient is −0.160 nm/% in the sodium chloride solution and −0.225 nm/% in the calcium chloride solution. The real-time monitoring test further verified the sensor’s sensing performance, with an absolute measurement error of less than 1.8%. The BFRP packaged sensor has good corrosion resistance and a simple structure, and it has a certain application value in the monitoring of salinity in the marine environment and coastal soil. Full article
Show Figures

Figure 1

18 pages, 3288 KiB  
Article
Influence of Material Optical Properties in Direct ToF LiDAR Optical Tactile Sensing: Comprehensive Evaluation
by Ilze Aulika, Andrejs Ogurcovs, Meldra Kemere, Arturs Bundulis, Jelena Butikova, Karlis Kundzins, Emmanuel Bacher, Martin Laurenzis, Stephane Schertzer, Julija Stopar, Ales Zore and Roman Kamnik
Materials 2025, 18(14), 3287; https://doi.org/10.3390/ma18143287 - 11 Jul 2025
Viewed by 404
Abstract
Optical tactile sensing is gaining traction as a foundational technology in collaborative and human-interactive robotics, where reliable touch and pressure feedback are critical. Traditional systems based on total internal reflection (TIR) and frustrated TIR (FTIR) often require complex infrared setups and lack adaptability [...] Read more.
Optical tactile sensing is gaining traction as a foundational technology in collaborative and human-interactive robotics, where reliable touch and pressure feedback are critical. Traditional systems based on total internal reflection (TIR) and frustrated TIR (FTIR) often require complex infrared setups and lack adaptability to curved or flexible surfaces. To overcome these limitations, we developed OptoSkin—a novel tactile platform leveraging direct time-of-flight (ToF) LiDAR principles for robust contact and pressure detection. In this extended study, we systematically evaluate how key optical properties of waveguide materials affect ToF signal behavior and sensing fidelity. We examine a diverse set of materials, characterized by varying light transmission (82–92)%, scattering coefficients (0.02–1.1) cm−1, diffuse reflectance (0.17–7.40)%, and refractive indices 1.398–1.537 at the ToF emitter wavelength of 940 nm. Through systematic evaluation, we demonstrate that controlled light scattering within the material significantly enhances ToF signal quality for both direct touch and near-proximity sensing. These findings underscore the critical role of material selection in designing efficient, low-cost, and geometry-independent optical tactile systems. Full article
(This article belongs to the Section Polymeric Materials)
Show Figures

Figure 1

17 pages, 4763 KiB  
Article
Multi-Band Terahertz Metamaterial Absorber Integrated with Microfluidics and Its Potential Application in Volatile Organic Compound Sensing
by Liang Wang, Bo Zhang, Xiangrui Dong, Qi Lu, Hao Shen, Yi Ni, Yuechen Liu and Haitao Song
Electronics 2025, 14(13), 2731; https://doi.org/10.3390/electronics14132731 - 7 Jul 2025
Viewed by 346
Abstract
In this study, a terahertz microfluidic multi-band sensor was designed. Unlike previous microfluidic absorption sensors that rely on dipole resonance, the proposed sensor uses a physical mechanism for absorption by exciting higher-order lattice resonances in microfluidic structures. With a Fabry–Perot cavity, the sensor [...] Read more.
In this study, a terahertz microfluidic multi-band sensor was designed. Unlike previous microfluidic absorption sensors that rely on dipole resonance, the proposed sensor uses a physical mechanism for absorption by exciting higher-order lattice resonances in microfluidic structures. With a Fabry–Perot cavity, the sensor can form an absorption peak with a high quality factor (Q) and narrow full width at half maximum (FWHM). A high Q value and a narrow FWHM are valuable in the field of sensing and provide strong support for high-precision sensing. On this basis, the sensing performance of the device was investigated. The simulation results clearly show that the absorption sensor has ultra-high sensitivity, which reaches 400 GHz/Refractive Index Unit (RIU). In addition, the sensor generates three absorption peaks, overcoming the limitations of a single frequency band in a composite resonance mode and multidimensional frequency response, which has potential application value in the field of volatile organic compound (VOC) sensing. Full article
Show Figures

Figure 1

16 pages, 9957 KiB  
Article
Analysis and Optimization of Rotationally Symmetric Au-Ag Alloy Nanoparticles for Refractive Index Sensing Properties Using T-Matrix Method
by Long Cheng, Shuhong Gong and Paerhatijiang Tuersun
Nanomaterials 2025, 15(13), 1052; https://doi.org/10.3390/nano15131052 - 6 Jul 2025
Viewed by 445
Abstract
Previous investigations devoted to non-spherical nanoparticles for biosensing have primarily addressed two hot topics, namely, finding nanoparticles with the best shape for refractive index sensing properties and the optimization of size parameters. In this study, based on these hot topics, Au-Ag alloy nanoparticles [...] Read more.
Previous investigations devoted to non-spherical nanoparticles for biosensing have primarily addressed two hot topics, namely, finding nanoparticles with the best shape for refractive index sensing properties and the optimization of size parameters. In this study, based on these hot topics, Au-Ag alloy nanoparticles with excellent optical properties were selected as the research object. Targeting rotationally symmetric Au-Ag alloy nanoparticles for biosensing applications, the complex media function correction model and T-matrix approach were used to systematically analyze the variation patterns of extinction properties, refractive index sensitivity, full width at half maximum, and figure of merit of three rotationally symmetric Au-Ag alloy nanoparticles with respect to the size of the particles and the Au molar fraction. In addition, we optimized the figure of merit to obtain the best size parameters and Au molar fractions for the three rotationally symmetric Au-Ag alloy nanoparticles. Finally, the range of dimensional parameters corresponding to a figure of merit greater than 98% of its maximum value was calculated. The results show that the optimized Au-Ag alloy nanorods exhibit a refractive index sensitivity of 395.2 nm/RIU, a figure of merit of 7.16, and a wide range of size parameters. Therefore, the optimized Au-Ag alloy nanorods can be used as high-performance biosensors. Furthermore, this study provides theoretical guidance for the application and preparation of rotationally symmetric Au-Ag alloy nanoparticles in biosensing. Full article
(This article belongs to the Special Issue Theoretical Calculation Study of Nanomaterials: 2nd Edition)
Show Figures

Figure 1

Back to TopTop