Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (11)

Search Parameters:
Keywords = sweeping gas membrane distillation

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
26 pages, 9145 KiB  
Article
Xe Recovery from Nuclear Power Plants Off-Gas Streams: Molecular Simulations of Gas Permeation through DD3R Zeolite Membrane
by Bandar J. Bashmmakh, Xiaoyu Wang, Cynthia J. Jameson and Sohail Murad
Membranes 2023, 13(9), 768; https://doi.org/10.3390/membranes13090768 - 30 Aug 2023
Cited by 1 | Viewed by 1857
Abstract
Recent experimental work has shown zeolite membrane-based separation as a promising potential technology for Kr/Xe gas mixtures due to its much lower energy requirements in comparison to cryogenic distillation, the conventional separation method for such mixtures. Such a separation is also economically rewarding [...] Read more.
Recent experimental work has shown zeolite membrane-based separation as a promising potential technology for Kr/Xe gas mixtures due to its much lower energy requirements in comparison to cryogenic distillation, the conventional separation method for such mixtures. Such a separation is also economically rewarding because Xe is in high demand, as a valuable product for many applications/processes. In this work, we have used Molecular Dynamics (MD) simulations to study the effects of different conditions, i.e., temperature, pressure, and gas feed composition, on Kr/Xe separation performance via DD3R zeolite membranes. We provide a comprehensive study of the permeation of the different gas species, density profiles, and diffusion coefficients. Molecular simulations show that if the feed is changed from pure Kr/Xe to an equimolar mixture, the Kr/Xe separation factor increases, which agrees with experiments. In addition, when Ar is introduced as a sweep gas, the adsorption of both Kr and Xe increases, while the permeation of pure Kr increases. A similar behavior is observed with equimolar mixtures of Kr/Xe with Ar as the sweep gas. High-separation Kr/Xe selectivity is observed at 50 atm and 425 K but with low total permeation rates. Changing pressure and temperature are found to have profound effects on optimizing the separation selectivity and the permeation throughput. Full article
Show Figures

Figure 1

27 pages, 8373 KiB  
Article
Comparative Energetics of Various Membrane Distillation Configurations and Guidelines for Design and Operation
by Md Rashedul Islam, Bosong Lin, Yue Yu, Chau-Chyun Chen and Mahdi Malmali
Membranes 2023, 13(3), 273; https://doi.org/10.3390/membranes13030273 - 24 Feb 2023
Cited by 10 | Viewed by 2976
Abstract
This paper presents a comparative performance study of single-stage desalination processes with major configurations of membrane distillation (MD) modules. MD modules covered in this study are (a) direct contact MD (DCMD), (b) vacuum MD (VMD), (c) sweeping gas MD (SGMD), and (d) air [...] Read more.
This paper presents a comparative performance study of single-stage desalination processes with major configurations of membrane distillation (MD) modules. MD modules covered in this study are (a) direct contact MD (DCMD), (b) vacuum MD (VMD), (c) sweeping gas MD (SGMD), and (d) air gap MD (AGMD). MD-based desalination processes are simulated with rigorous theoretical MD models supported by molecular thermodynamic property models for the accurate calculation of performance metrics. The performance metrics considered in MD systems are permeate flux and energy efficiency, i.e., gained output ratio (GOR). A general criterion is established to determine the critical length of these four MDs (at fixed width) for the feasible operation of desalination in a wide range of feed salinities. The length of DCMD and VMD is restricted by the feed salinity and permeate flux, respectively, while relatively large AGMD and SGMD are allowed. The sensitivity of GOR flux with respect to permeate conditions is investigated for different MD configurations. AGMD outperforms other configurations in terms of energy efficiency, while VMD reveals the highest permeate production. With larger MD modules, utilization of thermal energy supplied by the hot feed for evaporation is in the order of VMD > AGMD > SGMD > DCMD. Simulation results highlight that energy efficiency of the overall desalination process relies on the efficient recovery of spent for evaporation, suggesting potential improvement in energy efficiency for VMD-based desalination. Full article
(This article belongs to the Special Issue Advance in Thermal-Driven Membrane Processes)
Show Figures

Figure 1

18 pages, 2513 KiB  
Article
The Role of the Morphological Characterization of Multilayer Hydrophobized Ceramic Membranes on the Prediction of Sweeping Gas Membrane Distillation Performances
by Mohamed K. Fawzy, Felipe Varela-Corredor, Cristiana Boi and Serena Bandini
Membranes 2022, 12(10), 939; https://doi.org/10.3390/membranes12100939 - 27 Sep 2022
Cited by 2 | Viewed by 2291
Abstract
This paper shows which morphological characterization method is most appropriate to simulating membrane performance in sweeping gas membrane distillation in the case of multilayer hydrophobized ceramic membranes. As a case study, capillary four-layer hydrophobic carbon-based titania membranes arranged in bundles in a shell-and-tube [...] Read more.
This paper shows which morphological characterization method is most appropriate to simulating membrane performance in sweeping gas membrane distillation in the case of multilayer hydrophobized ceramic membranes. As a case study, capillary four-layer hydrophobic carbon-based titania membranes arranged in bundles in a shell-and-tube configuration were tested with NaCl-water solutions using air as sweeping gas, operating at temperatures from 40 to 110 °C and at pressures up to 5.3 bar. Contrary to what is generally performed for polymeric membranes and also suggested by other authors for ceramic membranes, the mass transfer across the membrane should be simulated using the corresponding values of the mean pore diameter and the porosity-tortuosity ratio of each layer and measured by the layer-by-layer (LBL) method. Comparison of the modeling results with experimental data highlights that the use of parameters averaged over the entire membrane leads to an overestimation by a factor of two to eight of the modeled fluxes, with respect to the experimental values. In contrast, the agreement between the modeled fluxes and the experimental values is very interesting when the LBL parameters are used, with a discrepancy on the order of +/−30%. Finally, the model has been used to investigate the role of operative parameters on process performances. Process efficiency should be the optimal balance between the concomitant effects of temperature and velocity of the liquid phase and pressure and velocity of the gas phase. Full article
(This article belongs to the Special Issue Honorary Issue for Prof João G. Crespo)
Show Figures

Figure 1

18 pages, 7604 KiB  
Article
Analysis and Experimental Study on Water Vapor Partial Pressure in the Membrane Distillation Process
by Zanshe Wang, Zhaoying Jia, Ran Li, Qi Gao and Zhaolin Gu
Membranes 2022, 12(8), 802; https://doi.org/10.3390/membranes12080802 - 19 Aug 2022
Cited by 6 | Viewed by 3218
Abstract
In membrane distillation, the vapor pressure difference is the driving force of mass transfer. The vapor pressure is generally assumed by the saturation pressure and calculated by the Antoine equation. However, in the actual operation process, the feed solutions usually flow in a [...] Read more.
In membrane distillation, the vapor pressure difference is the driving force of mass transfer. The vapor pressure is generally assumed by the saturation pressure and calculated by the Antoine equation. However, in the actual operation process, the feed solutions usually flow in a non-equilibrium state, which does not meet the theoretical and measurement conditions of the vapor-liquid equilibrium (VLE) state. This study tested the actual water vapor pressure of the pure water, lithium bromide (LiBr) solution, lithium chloride (LiCl) solution, and calcium chloride (CaCl2) solution under different flow conditions. The results showed that the actual water vapor pressure was lower than the saturation pressure overall, and the difference increased with temperature but decreased with the mass concentration. Therefore, in vacuum membrane distillation (VMD), air gap membrane distillation (AGMD), and sweeping gas membrane distillation (SGMD), the membrane flux calculated by water vapor saturation pressure was higher than the actual membrane flux, and the relative difference decreased and was less than 10% after 60 °C. In direct contact membrane distillation (DCMD), the water vapor pressure difference on both membrane sides was almost the same by using the saturation vapor pressure or the tested data since the pressure errors were partially offset in parallel flow or counter-flow modes. Full article
Show Figures

Figure 1

17 pages, 4030 KiB  
Article
The Application of Open Capillary Modules for Sweeping Gas Membrane Distillation
by Marek Gryta
Energies 2022, 15(4), 1454; https://doi.org/10.3390/en15041454 - 16 Feb 2022
Cited by 1 | Viewed by 1925
Abstract
The paper presents the sweeping gas membrane distillation realised by using the capillary module (length 1.1 m and area 0.1 m2) without housing (module shell). During the tests, the feed was flowing inside the hydrophobic polypropylene membranes. The studies were performed [...] Read more.
The paper presents the sweeping gas membrane distillation realised by using the capillary module (length 1.1 m and area 0.1 m2) without housing (module shell). During the tests, the feed was flowing inside the hydrophobic polypropylene membranes. The studies were performed for two variants of process: with pre-heating (313–330 K) and without heating of the feed (brines). Under low gas flow (0.005 m/s) the evaporation performance varied in the range of 0.15–0.25 L/m2h, depending on the relative humidity (42–63%) and the air temperature (293–300 K). The application of feed pre-heating to 330 K led to an increase in the evaporation performance to 2.4 L/m2h. The permeate flux increased by 60% when the air flow velocities between the capillaries increased to 1.8–2.5 m/s. Increasing the feed flow rate from 0.1 to 0.59 m/s led to increase the permeate flux about 20% for feed temperature 293–310 K, and over 55% for feed temperature higher than 323 K. Full article
(This article belongs to the Special Issue Thermal Performance of Membrane Distillation)
Show Figures

Figure 1

18 pages, 3765 KiB  
Article
Fully Polymeric Distillation Unit Based on Polypropylene Hollow Fibers
by Tereza Kůdelová, Erik Bartuli, Alan Strunga, Jiří Hvožďa and Miroslav Dohnal
Polymers 2021, 13(7), 1031; https://doi.org/10.3390/polym13071031 - 26 Mar 2021
Cited by 17 | Viewed by 2661
Abstract
Access to pure water is a very topical issue today. Desalination represents a promising way of obtaining drinking water in areas of shortage. Currently, efforts are being made to replace the metal components of existing desalination units due to the high corrosivity of [...] Read more.
Access to pure water is a very topical issue today. Desalination represents a promising way of obtaining drinking water in areas of shortage. Currently, efforts are being made to replace the metal components of existing desalination units due to the high corrosivity of sea water. Another requirement is easy transportation and assembly. The presented solution combines two types of polymeric hollow fibers that are used to create the distillation unit. Porous polypropylene hollow fiber membranes have been used as an active surface for mass transfer in the distillation unit, while non-porous thermal polypropylene hollow fibers have been employed in the condenser. The large active area to volume ratio of the hollow fiber module improves the efficiency of both units. Hot water is pumped inside the membranes in the distillation unit. Evaporation is first observed at a temperature gradient of 10 °C. The water vapor flows through the tunnel to the condenser where cold water runs inside the fibers. The temperature gradient causes condensation of the vapor, and the condensate is collected. The article presents data for hot water at temperatures of 55, 60, and 65 °C. Optimization of the membrane module is evaluated and presented. Full article
(This article belongs to the Section Polymer Applications)
Show Figures

Graphical abstract

27 pages, 1658 KiB  
Review
Review of Transport Phenomena and Popular Modelling Approaches in Membrane Distillation
by Yan Dong, Xiaodong Dai, Lianyu Zhao, Li Gao, Zongli Xie and Jianhua Zhang
Membranes 2021, 11(2), 122; https://doi.org/10.3390/membranes11020122 - 8 Feb 2021
Cited by 46 | Viewed by 5729
Abstract
In this paper, the transport phenomena in four common membrane distillation (MD) configurations and three popular modelling approaches are introduced. The mechanism of heat transfer on the feed side of all configurations are the same but are distinctive from each other from the [...] Read more.
In this paper, the transport phenomena in four common membrane distillation (MD) configurations and three popular modelling approaches are introduced. The mechanism of heat transfer on the feed side of all configurations are the same but are distinctive from each other from the membrane interface to the bulk permeate in each configuration. Based on the features of MD configurations, the mechanisms of mass and heat transfers for four configurations are reviewed together from the bulk feed to the membrane interface on the permeate but reviewed separately from the interface to the bulk permeate. Since the temperature polarisation coefficient cannot be used to quantify the driving force polarisation in Sweeping Gas MD and Vacuum MD, the rate of driving force polarisation is proposed in this paper. The three popular modelling approaches introduced are modelling by conventional methods, computational fluid dynamics (CFD) and response surface methodology (RSM), which are based on classic transport mechanism, computer science and mathematical statistics, respectively. The default assumptions, area for applications, advantages and disadvantages of those modelling approaches are summarised. Assessment and comparison were also conducted based on the review. Since there are only a couple of full-scale plants operating worldwide, the modelling of operational cost of MD was only briefly reviewed. Gaps and future studies were also proposed based on the current research trends, such as the emergence of new membranes, which possess the characteristics of selectivity, anti-wetting, multilayer and incorporation of inorganic particles. Full article
Show Figures

Graphical abstract

18 pages, 5818 KiB  
Article
A Systematic Framework for Optimizing a Sweeping Gas Membrane Distillation (SGMD)
by Nawras N. Safi, Salah. S. Ibrahim, Nasser Zouli, Hasan Shaker Majdi, Qusay F. Alsalhy, Enrico Drioli and Alberto Figoli
Membranes 2020, 10(10), 254; https://doi.org/10.3390/membranes10100254 - 24 Sep 2020
Cited by 22 | Viewed by 3241
Abstract
The present work has undertaken a meticulous glance on optimizing the performance of an SGMD configuration utilized a porous poly (vinylidene fluoride-co-hexafluoropropylene) (PVDF-co-HFP) membrane. This was carried out by conducting a systematic framework for investigating and optimizing the pertinent parameters such [...] Read more.
The present work has undertaken a meticulous glance on optimizing the performance of an SGMD configuration utilized a porous poly (vinylidene fluoride-co-hexafluoropropylene) (PVDF-co-HFP) membrane. This was carried out by conducting a systematic framework for investigating and optimizing the pertinent parameters such as sweeping gas flow rate, feed temperature, feed concentration and feed flow rate on the permeate flux. For this purpose, the Taguchi method and design of experiment techniques were harnessed to statistically determine optimum operational conditions. Besides that, a comprehensive surface and permeation characterization was conducted against the hand-made membranes. Results showcased that the membrane performance was ultimately controlled by the feed temperature and was nearly (~680) % higher when the temperature raised from 45 to 65 °C. Also, to a lesser extent, the system was dominated by the feed flow rate. As the adopted feed flow rate increases (from 0.2 to 0.6 L/min), around 47.5% increment was bestowed on water permeability characteristics. In contra, 34.5% flux decline was witnessed when higher saline feed concentration (100 g/L) was utilized. In the meantime, with raising the sweeping gas flow rate (from 120 to 300 L/h), the distillate was nearly 129% higher. Based on Taguchi design, the maximum permeate flux (17.3 and 17 kg/m2·h) was secured at 35 g/L, 0.4 L/min, 65 °C and 300 L/h, for both commercial and prepared membranes, respectively. Full article
Show Figures

Figure 1

16 pages, 2576 KiB  
Article
Removal and Recovery of Methyl Tertiary Butyl Ether (MTBE) from Water Using Carbon Nanotube and Graphene Oxide Immobilized Membranes
by Worawit Intrchom, Sagar Roy and Somenath Mitra
Nanomaterials 2020, 10(3), 578; https://doi.org/10.3390/nano10030578 - 22 Mar 2020
Cited by 15 | Viewed by 4269
Abstract
Methyl tert-butyl ether (MTBE) is a widely used gasoline additive that has high water solubility, and is difficult to separate from contaminated ground and surface waters. We present the development in functionalized carbon nanotube-immobilized membranes (CNIM-f) and graphene oxide-immobilized membranes (GOIM) for enhanced [...] Read more.
Methyl tert-butyl ether (MTBE) is a widely used gasoline additive that has high water solubility, and is difficult to separate from contaminated ground and surface waters. We present the development in functionalized carbon nanotube-immobilized membranes (CNIM-f) and graphene oxide-immobilized membranes (GOIM) for enhanced separation of MTBE via sweep gas membrane distillation (SGMD). Both types of modified membranes demonstrated high performance in MTBE removal from its aqueous mixture. Among the membranes studied, CNIM-f provided the best performance in terms of flux, removal efficiency, mass transfer coefficients and overall selectivity. The immobilization f-CNTs and GO altered the surface characteristics of the membrane and enhanced partition coefficients, and thus assisted MTBE transport across the membrane. The MTBE flux reached as high as 1.4 kg/m2 h with f-CNTs, which was 22% higher than that of the unmodified PTFE membrane. The maximum MTBE removal using CNIM-f reached 56% at 0.5 wt % of the MTBE in water, and at a temperature of 30 °C. With selectivity as high as 60, MTBE recovery from contaminated water is very viable using these nanocarbon-immobilized membranes. Full article
(This article belongs to the Special Issue Investigation and Development of Graphene Oxide-Based Materials)
Show Figures

Graphical abstract

16 pages, 4182 KiB  
Article
Concentration of 1,3-dimethyl-2-imidazolidinone in Aqueous Solutions by Sweeping Gas Membrane Distillation: From Bench to Industrial Scale
by Ricardo Abejón, Hafedh Saidani, André Deratani, Christophe Richard and José Sánchez-Marcano
Membranes 2019, 9(12), 158; https://doi.org/10.3390/membranes9120158 - 26 Nov 2019
Cited by 9 | Viewed by 3529
Abstract
Sweeping gas membrane distillation (SGMD) is a useful option for dehydration of aqueous solvent solutions. This study investigated the technical viability and competitiveness of the use of SGMD to concentrate aqueous solutions of 1,3-dimethyl-2-imidazolidinone (DMI), a dipolar aprotic solvent. The concentration from 30% [...] Read more.
Sweeping gas membrane distillation (SGMD) is a useful option for dehydration of aqueous solvent solutions. This study investigated the technical viability and competitiveness of the use of SGMD to concentrate aqueous solutions of 1,3-dimethyl-2-imidazolidinone (DMI), a dipolar aprotic solvent. The concentration from 30% to 50% of aqueous DMI solutions was attained in a bench installation with Liqui-Cel SuperPhobic® hollow-fiber membranes. The selected membranes resulted in low vapor flux (below 0.15 kg/h·m2) but were also effective for minimization of DMI losses through the membranes, since these losses were maintained below 1% of the evaporated water flux. This fact implied that more than 99.2% of the DMI fed to the system was recovered in the produced concentrated solution. The influence of temperature and flowrate of the feed and sweep gas streams was analyzed to develop simple empirical models that represented the vapor permeation and DMI losses through the hollow-fiber membranes. The proposed models were successfully applied to the scaling-up of the process with a preliminary multi-objective optimization of the process based on the simultaneous minimization of the total membrane area, the heat requirement and the air consumption. Maximal feed temperature and air flowrate (and the corresponding high operation costs) were optimal conditions, but the excessive membrane area required implied an uncompetitive alternative for direct industrial application. Full article
(This article belongs to the Special Issue Membrane Distillation Process)
Show Figures

Figure 1

14 pages, 2389 KiB  
Article
Concentrating of Sugar Syrup in Bioethanol Production Using Sweeping Gas Membrane Distillation
by Mohammad Mahdi A. Shirazi and Ali Kargari
Membranes 2019, 9(5), 59; https://doi.org/10.3390/membranes9050059 - 1 May 2019
Cited by 14 | Viewed by 4762
Abstract
Membrane distillation (MD) is a relatively new and underdeveloped separation process which can be classified as a green technology. However, in order to investigate its dark points, sensitivity analysis and optimization studies are critical. In this work, a number of MD experiments were [...] Read more.
Membrane distillation (MD) is a relatively new and underdeveloped separation process which can be classified as a green technology. However, in order to investigate its dark points, sensitivity analysis and optimization studies are critical. In this work, a number of MD experiments were performed for concentrating glucose syrup using a sweeping gas membrane distillation (SGMD) process as a critical step in bioethanol production. The experimental design method was the Taguchi orthogonal array (an L9 orthogonal one) methodology. The experimental results showed the effects of various operating variables, including temperature (45, 55, and 65 °C), flow rate (200, 400, and 600 ml/min) and glucose concentration (10, 30, and 50 g/l) of the feed stream, as well as sweeping gas flow rate (4, 10, and 16 standard cubic feet per hour (SCFH)) on the permeate flux. The main effects of the operating variables were reported. An ANOVA analysis showed that the most and the least influenced variables were feed temperature and feed flow rate, each one with 62.1% and 6.1% contributions, respectively. The glucose rejection was measured at 99% for all experiments. Results indicated that the SGMD process could be considered as a versatile and clean process in the sugar concentration step of the bioethanol production. Full article
(This article belongs to the Special Issue Membrane Distillation Process)
Show Figures

Figure 1

Back to TopTop