Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = translucent ceiling

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 24564 KB  
Article
An Evaluation of Useful Daylight Illuminance in an Office Room with a Light Shelf and Translucent Ceiling at 51° N
by Marcin Brzezicki
Buildings 2021, 11(11), 494; https://doi.org/10.3390/buildings11110494 - 20 Oct 2021
Cited by 19 | Viewed by 5329
Abstract
The present study investigates the issue of computer-aided daylight evaluation in an office room with a light shelf and dropped translucent ceiling. In this type of room, daylight is admitted from two sources: (i) a standard window in the wall and [...] Read more.
The present study investigates the issue of computer-aided daylight evaluation in an office room with a light shelf and dropped translucent ceiling. In this type of room, daylight is admitted from two sources: (i) a standard window in the wall and (ii) via a light shelf and clerestory window, which illuminate the plenum located above the working space. The light from the plenum is transmitted through the translucent ceiling into the office room. The present study is based on data obtained through a computer-aided daylight simulation by DeLuminæ (DL-Light, ver. 11.0.9, and DL-Instant, ver. 6.1.4) software using the Radiance engine and real weather data for Wroclaw, Poland, at 51st lat. N. An office room of 12 × 6 m with different shading and daylight distribution scenarios was simulated (Variants 1–5). Next, the useful daylight illuminance (UDI (%)) for the range of 300–3000 lx and daylight glare probability (DGP) were calculated. To further optimize the daylighting scenarios, an adaptive shading system was simulated, which was activated when the illuminance value dropped below 300 lx. In the final variant, Variant 6, mean UDI300–3000 values were recorded to be above 80% for 95% of the area of the work plane. This allows the conclusion that a light shelf and translucent ceiling guide daylight deep into the room, improving uniformity and reducing glare when the standard window is covered by an adaptive shading system. Full article
(This article belongs to the Special Issue Architecture, City, People, and Structure)
Show Figures

Figure 1

18 pages, 3838 KB  
Article
An Evaluation of Annual Luminous Exposure from Daylight in a Museum Room with a Translucent Ceiling
by Marcin Brzezicki
Buildings 2021, 11(5), 193; https://doi.org/10.3390/buildings11050193 - 2 May 2021
Cited by 5 | Viewed by 4221
Abstract
The current study investigates the issue of computer-aided daylight evaluation in a museum room with a dropped translucent ceiling. In this type of room, daylight is admitted through classic windows located in the facade and then distributed in the plenum, which is located [...] Read more.
The current study investigates the issue of computer-aided daylight evaluation in a museum room with a dropped translucent ceiling. In this type of room, daylight is admitted through classic windows located in the facade and then distributed in the plenum, which is located above the exhibition space and transmitted through the translucent ceiling into the museum room. This illumination method enables guiding daylight deep into the room, excluding the impact of direct solar radiation. The presented study is based on data obtained through computer-aided daylight simulation by DeLuminæ (DL-Light, ver. 11.0.9) software using the Radiance software for all calculations and real weather data for Wroclaw, Poland. A museum room of 12 × 12 m with three different heights of the plenums was simulated to establish an optimal relation of the width to height plenum ratio. Next, the annual exposure in K lx·h/year was calculated, as sensitive works of art may be subjected to damage caused by light exposure. To further reduce illumination, the simulation of an automatic shading system in the form of horizontal louvers was performed. The system was activated when certain illumination values were detected by the sensor on the building’s roof. Full article
(This article belongs to the Special Issue Visual Comfort in Buildings: Lighting Solutions)
Show Figures

Figure 1

Back to TopTop