Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (15)

Search Parameters:
Keywords = tricuspid annuloplasty

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 2290 KB  
Article
Automated Annuloplasty with VirtuoSEW® in microInvasive Mitral Valve Repair (μMVr)
by Nermir Granov, Farhad Bakhtiary, Armin Šljivo and Jude S. Sauer
Med. Sci. 2026, 14(2), 187; https://doi.org/10.3390/medsci14020187 - 9 Apr 2026
Viewed by 547
Abstract
Background/Objectives: Totally endoscopic mitral valve repair reduces surgical trauma and accelerates recovery but can be technically challenging, particularly for precise annuloplasty suturing. The VirtuoSEW® (LSI Solutions, Victor, NY 14564m, USA) automated annular suturing system was developed to standardize and simplify suture [...] Read more.
Background/Objectives: Totally endoscopic mitral valve repair reduces surgical trauma and accelerates recovery but can be technically challenging, particularly for precise annuloplasty suturing. The VirtuoSEW® (LSI Solutions, Victor, NY 14564m, USA) automated annular suturing system was developed to standardize and simplify suture placement. This study was an early evaluation of this technology’s safety, efficacy, and feasibility in totally endoscopic microInvasive mitral valve repair (µMVr). Methods: We conducted a retrospective observational study of 20 patients with severe mitral valve disease of various etiologies. All patients underwent mitral valve repair using the VirtuoSEW® system for automated placement of annuloplasty sutures, combined with leaflet resection or chordal management as appropriate. Postoperative outcomes were assessed at one month using echocardiography and clinical evaluation. Perioperative and postoperative complications and early mortality were systematically recorded. Results: VirtuoSEW®-assisted mitral valve repair was safe and effective, achieving complete elimination of severe mitral regurgitation in all patients (N = 20, 100%). Annuloplasty rings included Physio-ring (N = 12, 60%), Memo 3D (N = 4, 20%), and Memo 4D (N = 4, 20%), combined with leaflet repair techniques: leaflet plication (N = 5, 25%), neochordae implantation (N = 7, 35%), sliding plasty (N = 2, 10%), commissural repair (N = 1, 5%), and hemibutterfly repair (N = 1, 5%). Concomitant procedures included: tricuspid valve repair (N = 1, 5%) and atrial septal defect closure (N = 1, 5%). Mitral annulus diameter decreased from 42.0 ± 5.3 mm to 34.2 ± 2.2 mm (p = 0.001). Mean total surgery, cardiopulmonary bypass, and aortic cross-clamp times were 170.3 ± 21.3, 143.4 ± 21.5, and 80.4 ± 7.9 min, respectively. ICU stay was 1.0 ± 0.2 days, with a hospital stay of 8.0 ± 1.9 days. No perioperative complications—including bleeding (N = 0, 0%), stroke (N = 0, 0%), infections (N = 0, 0%), or 30-day mortality (N = 0, 0%)—occurred. Conclusions: µMVR invasive mitral valve repair using the VirtuoSEW® system is safe, effective, and reproducible, as well as compatible with almost all repair techniques, providing complete restoration of valve competence with no early device-related complications. To our knowledge, this is the first clinical study reporting outcomes with this device, supporting its potential to streamline mitral repair and improve procedural efficiency. Full article
(This article belongs to the Section Cardiovascular Disease)
Show Figures

Figure 1

12 pages, 1158 KB  
Article
Prevalence and Importance of Tricuspid Valve Prolapse in Patients with Primary Mitral Regurgitation
by Aniek L. van Wijngaarden, Anton Tomsic, Nadeem Elmasry, Hoi W. Wu, Meindert Palmen, Jeroen J. Bax and Nina Ajmone Marsan
J. Cardiovasc. Dev. Dis. 2026, 13(3), 106; https://doi.org/10.3390/jcdd13030106 - 24 Feb 2026
Viewed by 875
Abstract
The presence and impact of tricuspid valve (TV) prolapse in patients with mitral valve (MV) prolapse and severe mitral regurgitation (MR) have not been widely reported. The aim of our study was to describe the prevalence of TV prolapse, and the associated echocardiography [...] Read more.
The presence and impact of tricuspid valve (TV) prolapse in patients with mitral valve (MV) prolapse and severe mitral regurgitation (MR) have not been widely reported. The aim of our study was to describe the prevalence of TV prolapse, and the associated echocardiography features, in a large cohort of patients with MV prolapse undergoing surgery, and to explore its potential clinical impact. A total of 803 patients were included, of which 87 (11%) were diagnosed with TV prolapse, while 716 (89%) patients showed no TV prolapse. Patients with TV prolapse were more often diagnosed with Barlow’s disease compared to patients without TV prolapse, and also had more frequently significant TR, a larger right chamber size and TV annulus; they also underwent concomitant TV annuloplasty more often. During follow-up, there was no difference in terms of TR progression or all-cause mortality after surgery between the patients with or without TV prolapse. In conclusion, TV prolapse was associated with a more severe phenotype in terms of baseline cardiac remodeling and TR severity in our large study cohort of MV prolapse patients undergoing MV repair. However, when successfully treated, TV prolapse was not associated with worse outcomes after surgery, also in terms of TR progression. Full article
Show Figures

Figure 1

9 pages, 2106 KB  
Case Report
Late Diagnosis of Unroofed Coronary Sinus Associated with Persistent Left Superior Vena Cava in Patient with Repaired Tetralogy of Fallot: Case Report
by Oana Gheorghe-Fronea, Mircea Robu, Sebastian Onciul, Claudia Nica, Cristian Voica, Robert Țigănașu, Gabriel-Petre Gorecki and Horațiu Moldovan
Life 2026, 16(2), 342; https://doi.org/10.3390/life16020342 - 16 Feb 2026
Viewed by 724
Abstract
Background: An unroofed coronary sinus (UCS) is a rare congenital cardiac anomaly, accounting for less than 1% of atrial septal defects and frequently associated with a persistent left superior vena cava (PLSVC). Its coexistence with Tetralogy of Fallot (TOF) is exceptionally uncommon and [...] Read more.
Background: An unroofed coronary sinus (UCS) is a rare congenital cardiac anomaly, accounting for less than 1% of atrial septal defects and frequently associated with a persistent left superior vena cava (PLSVC). Its coexistence with Tetralogy of Fallot (TOF) is exceptionally uncommon and has been reported almost exclusively in isolated case reports. Case Presentation: We report the case of a 20-year-old woman with a history of surgically corrected TOF in infancy, who presented with progressive exertional dyspnea. Multimodality imaging, including transthoracic echocardiography and cardiac magnetic resonance imaging, revealed a large atrial-level shunt caused by a type I unroofed coronary sinus associated with a persistent left superior vena cava, leading to significant right-sided chamber dilation and pulmonary hypertension. Notably, this anomaly had not been identified at the time of the initial TOF repair. The patient underwent a successful surgical correction with interatrial compartmentation and tricuspid annuloplasty, with an uneventful postoperative course. Conclusions: This case underscores the extreme rarity of the UCS–TOF association and highlights the potential for UCSs with PLSVC to remain clinically silent for years after complex congenital heart surgery. A comprehensive reassessment of the systemic venous and atrial anatomy using advanced multimodality imaging is essential in symptomatic adults with repaired TOF, as late-presenting venous anomalies may have significant hemodynamic and clinical implications. Full article
(This article belongs to the Section Medical Research)
Show Figures

Figure 1

15 pages, 4192 KB  
Review
Transcatheter Tricuspid Valve Annuloplasty with the Cardioband System: A Step-by-Step Guide
by Maria Laura Novembre, Lluis Asmarats, Chi Hion Pedro Li, Marcel Santaló-Corcoy, Xavier Millán and Dabit Arzamendi
J. Clin. Med. 2025, 14(21), 7772; https://doi.org/10.3390/jcm14217772 - 1 Nov 2025
Viewed by 1084
Abstract
Direct transcatheter tricuspid valve annuloplasty represents a significant advancement in the treatment of severe symptomatic tricuspid regurgitation. Previous studies have shown the efficacy of transcatheter annuloplasty with significant reductions in tricuspid regurgitation and improvements in functional status. The aim of this review is [...] Read more.
Direct transcatheter tricuspid valve annuloplasty represents a significant advancement in the treatment of severe symptomatic tricuspid regurgitation. Previous studies have shown the efficacy of transcatheter annuloplasty with significant reductions in tricuspid regurgitation and improvements in functional status. The aim of this review is to provide a comprehensive step-by-step guide to the procedure, focusing on appropriate patient selection, main procedural steps and identification and management of possible complications to enhance our understanding of the procedure and maximize procedural success. Full article
Show Figures

Figure 1

11 pages, 1849 KB  
Article
Outcomes of K-Clip Implantation for Functional Tricuspid Regurgitation Accompanied with Persistent Atrial Fibrillation
by Da-Wei Lin, Ling-Wei Zou, Jia-Xin Miao, Jia-Ning Fan, Min-Fang Meng, Yi-Ming Qi, Zhi Zhan, Wen-Zhi Pan, Da-Xin Zhou, Xiao-Chun Zhang and Jun-Bo Ge
J. Cardiovasc. Dev. Dis. 2025, 12(2), 55; https://doi.org/10.3390/jcdd12020055 - 3 Feb 2025
Cited by 2 | Viewed by 2051
Abstract
Background: Atrial fibrillation (AF) has been identified as a risk factor for functional tricuspid regurgitation (FTR) in the absence of other known etiologies, although limited interventional options are available. K-Clip™, a novel transcatheter tricuspid annuloplasty device, is a clip-based annular plication approach for [...] Read more.
Background: Atrial fibrillation (AF) has been identified as a risk factor for functional tricuspid regurgitation (FTR) in the absence of other known etiologies, although limited interventional options are available. K-Clip™, a novel transcatheter tricuspid annuloplasty device, is a clip-based annular plication approach for FTR. To date, no studies have investigated the short-term outcomes of K-Clip™ for patients with severe FTR associated with AF. Therefore, the aim of this study was to explore the feasibility and effectiveness of transcatheter annular repair with K-Clip™ for FTR in patients with persistent AF. Methods: Patients with FTR and persistent AF who underwent transcatheter annular repair with K-Clip™ at nine centers in China during the inclusion period were included (This study derived from Confirmatory Clinical Study of Treating Tricuspid Regurgitation With K-Clip™ Transcatheter Annuloplasty System [TriStar study}). Baseline data, imaging results, and follow-up data were collected. Results: All 52 patients (23 men, 74.02 ± 7.03 years) received successful intervention, and the mean operation time and radian exposure were 2.64 ± 1.09 h and 133.33 ± 743.06 mGy, respectively. No death cases and a low major adverse event occurrence rate were reported in 30 days. A significant decrease in FTR was documented, and TR remained severe in only two patients (3.8%). The regurgitation volume decreased significantly, accompanied by a notable reduction in the effective regurgitation orifice area and tricuspid annulus diameter, which subsequently led to the reversal of right heart remodeling. Furthermore, a decrease in pulmonary artery systolic pressure and an increase in cardiac output were documented. Conclusions: Transcatheter annular repair with K-Clip™ showed favorable short-term prognosis and significant improvement in FTR in patients with severe FTR associated with persistent AF. K-Clip™ could be a novel option for that group of patients. Full article
(This article belongs to the Section Cardiovascular Clinical Research)
Show Figures

Figure 1

15 pages, 2028 KB  
Article
Preoperative Predictors of Recurrent Tricuspid Regurgitation After Annuloplasty: Insights into the Role of 3D Echocardiography
by Aušra Krivickienė, Dovydas Verikas, Lina Padervinskienė, Vaida Mizarienė, Adakrius Siudikas, Povilas Jakuška, Jolanta Justina Vaškelytė and Eglė Ereminienė
Diagnostics 2024, 14(22), 2515; https://doi.org/10.3390/diagnostics14222515 - 10 Nov 2024
Viewed by 1724
Abstract
Background: While tricuspid annuloplasty (TAP) is an effective treatment option for tricuspid regurgitation (TR), understanding the echocardiographic factors contributing to recurrent TR can help in developing more effective preventive measures to reduce the rate of recurrent TR after TAP. Methods: This study was [...] Read more.
Background: While tricuspid annuloplasty (TAP) is an effective treatment option for tricuspid regurgitation (TR), understanding the echocardiographic factors contributing to recurrent TR can help in developing more effective preventive measures to reduce the rate of recurrent TR after TAP. Methods: This study was designed as a prospective observational cohort study to investigate factors contributing to recurrent TR following surgical tricuspid valve (TV) repair in patients with moderate or severe functional TR caused by left heart valvular disease, with severe mitral regurgitation as the dominant pathology. The study included 66 patients who underwent preoperative two-dimensional (2D) and three-dimensional (3D) echocardiographic assessments. Patients were divided into two groups based on TAP outcomes: the effective TAP group and the recurrent TR group. Results: The analysis revealed that 3D-derived both septal–lateral diastolic and systolic tricuspid annulus (TA) diameter (odds ratio (OR) 1.77; 95% confidence interval (CI) 1.17–2.68 and OR 1.62; 95% CI 1.14–2.29, respectively), and major axis diastolic TA diameter (OR 1.59; 95% CI 1.15–2.2) had the highest OR among all echocardiographic parameters. The further univariate analysis of predefined echocardiographic values unveiled that the combined effect of heightened 3D-measured TA major axis diastolic diameter and increased right ventricle (RV) basal diameter exhibited the highest OR at 12.8 (95% CI 2.3–72.8) for a recurrent TR. Using ROC analysis, diastolic major axis (area under the curve (AUC) 0.848; cut-off 48.5 mm), septal-lateral systolic (AUC 0.840; cut-off 43.5 mm) and diastolic (AUC 0.840; cut-off 46.5 mm) TA diameter demonstrated the highest predictive value for recurrent TR from all TV parameters. Conclusions: Recurrent moderate or severe TR after TAP is associated with preoperative TA size, right atrium and RV geometry, but not with changes of RV function. The predictive capacity of 2D-assessed echocardiographic parameters was found to be lower when compared to their corresponding 3D parameters. Full article
(This article belongs to the Special Issue Advances in Echocardiography)
Show Figures

Figure 1

19 pages, 771 KB  
Systematic Review
Transcatheter Repair of Tricuspid Valve Regurgitation: A Systematic Review
by Aswin Srinivasan, Jonathan Brown, Alexander Rhodes, Sobia Khan, Viswanath Chinta, Pranav Loyalka and Arnav Kumar
J. Clin. Med. 2024, 13(21), 6531; https://doi.org/10.3390/jcm13216531 - 30 Oct 2024
Cited by 4 | Viewed by 3218
Abstract
Introduction: Clinically significant severe tricuspid regurgitation (TR) is a common untreated pathology associated with increased mortality. Even though surgical valve replacement has been the mainstay option, transcatheter intervention is a novel and potentially effective tool. To the best of our knowledge, this is [...] Read more.
Introduction: Clinically significant severe tricuspid regurgitation (TR) is a common untreated pathology associated with increased mortality. Even though surgical valve replacement has been the mainstay option, transcatheter intervention is a novel and potentially effective tool. To the best of our knowledge, this is the first systematic review that assessed and compared clinical and echocardiographic outcomes of coaptation and annuloplasty devices in patients with clinically significant TR. Methods: PubMed, the Cochrane Central Register of Controlled Trials, and EMBASE were searched for articles published from August 2016 until February 2023. Primary endpoints were technical and procedural successes. Secondary endpoints were TR grade, NYHA, change in 6 min walk distance (6MWD), and echocardiographic parameters at 30-day follow-up. Results: We included thirty-eight studies consisting of 2273 patients with severe symptomatic TR (NYHA III-IV 77% and severe/massive/torrential TR 83.3%) and high surgical risk (mean EUROSCORE of 7.54). The technical success for the annuloplasty devices was 96.7% and for the coaptation device was 94.8%. The procedural success for the annuloplasty devices was 64.6% and for the coaptation device was 81.4%. The 6MWD increased by 17 m for the coaptation devices and increased by 44 m after 30 days for the annuloplasty devices. A reduction in TR grade to <2 was seen in 70% of patients with coaptation and 59% of patients with annuloplasty devices. Conclusions: Transcatheter tricuspid valve intervention appears to be feasible and is associated with favorable outcomes. Full article
(This article belongs to the Section Cardiology)
Show Figures

Figure 1

24 pages, 6435 KB  
Review
Emerging Transcatheter Therapies for Valvular Heart Disease: Focus on Mitral and Tricuspid Valve Procedures
by Nikolaos Ktenopoulos, Odysseas Katsaros, Anastasios Apostolos, Maria Drakopoulou, Grigorios Tsigkas, Constantinos Tsioufis, Periklis Davlouros, Konstantinos Toutouzas and Antonios Karanasos
Life 2024, 14(7), 842; https://doi.org/10.3390/life14070842 - 2 Jul 2024
Cited by 9 | Viewed by 3184
Abstract
The emergence of percutaneous treatment options provides novel therapeutic alternatives for older and feeble patients who are at high risk for any surgical procedure. The purpose of our review was to offer an up-to-date analysis of the rapidly expanding field of percutaneous technologies [...] Read more.
The emergence of percutaneous treatment options provides novel therapeutic alternatives for older and feeble patients who are at high risk for any surgical procedure. The purpose of our review was to offer an up-to-date analysis of the rapidly expanding field of percutaneous technologies for mitral, tricuspid, and pulmonary procedures. Edge-to-edge repair is an established treatment for secondary mitral regurgitation (MR), while transcatheter mitral valve replacement is a potential and expanding option for managing both secondary and primary MR. However, additional advancements are necessary to enhance the safety and feasibility of this procedure. Transcatheter tricuspid intervention is an emerging option that was conceived after the success of transcatheter procedures in aortic and mitral valves, and it is currently still in the early stages of advancement. This can be attributed, at least in part, to the previously overlooked effect of tricuspid regurgitation on patient outcomes. The development of edge-to-edge repair represents the forefront of innovations in transcatheter procedures. There is a scarcity of data about tricuspid annuloplasty and replacement, and further study is necessary. Transcatheter mitral, tricuspid, and pulmonary procedures show prospects for the future, while their role in clinical practice has not been definitively established. Full article
(This article belongs to the Special Issue Recent Advances in Modern Thoracic Surgery)
Show Figures

Figure 1

8 pages, 3085 KB  
Article
Modified Clover Technique Using Automated Suture Placement and Securing Technology in a Passive Beating Heart Model
by Severin Laengle, Aldo Suria, Thomas Poschner, Sahra Tasdelen, Antonios Pitsis, Alfred Kocher and Martin Andreas
Bioengineering 2024, 11(7), 666; https://doi.org/10.3390/bioengineering11070666 - 29 Jun 2024
Viewed by 3261
Abstract
Tricuspid regurgitation (TR) is a prevalent finding in echocardiography and in case of severe disease is associated with impaired patient outcome. Clover repair offers a surgical solution that can be applied for the treatment of primary and secondary TR. An ex vivo passive [...] Read more.
Tricuspid regurgitation (TR) is a prevalent finding in echocardiography and in case of severe disease is associated with impaired patient outcome. Clover repair offers a surgical solution that can be applied for the treatment of primary and secondary TR. An ex vivo passive beating porcine heart model was created to test a modified clover technique using automated suturing devices and to compare this approach to standard ring annuloplasty. Secondary TR was induced in 10 porcine hearts and the backflow of fluid was assessed. The primary endpoint of this study was regurgitant volume measured in mL at the site right atrial cannula. The baseline regurgitation was 43.3 ± 10.8 mL. The mean regurgitant volume was significantly reduced after all repair procedures to 22.2 ± 5.9 mL with isolated ring annuloplasty, 12 ± 3.9 mL with the modified clover, and 7.6 ± 3.4 mL with the combined procedure (p < 0.0001). The modified clover technique shows how to effectively reduce TR in an ex vivo model. This method may be suitable to facilitate tricuspid repair, especially for totally endoscopic valve surgery. Full article
Show Figures

Graphical abstract

8 pages, 1266 KB  
Case Report
An Unusual Case of Cardiac Mass: A Multimodal Approach in Diagnosis and Treatment
by Ljiljana Rankovic-Nicic, Milica Dragicevic-Antonic, Zelimir Antonic, Vladimir Mihajlovic, Masa Petrovic, Tjasa Ivosevic, Gordana Stamenkovic, Svetislav Pelemis and Milovan Bojic
Healthcare 2024, 12(10), 1009; https://doi.org/10.3390/healthcare12101009 - 14 May 2024
Viewed by 2819
Abstract
Diagnosing intracardiac masses poses a complex, multimodal challenge. We present the case of a 72-year-old woman with a history of rheumatic fever leading to mitral stenosis and a previous mitral valve commissurotomy who reported fatigue, weakness, and palpitations over the past three months. [...] Read more.
Diagnosing intracardiac masses poses a complex, multimodal challenge. We present the case of a 72-year-old woman with a history of rheumatic fever leading to mitral stenosis and a previous mitral valve commissurotomy who reported fatigue, weakness, and palpitations over the past three months. Echocardiography revealed a tumor (53 × 40 mm) in the enlarged left atrium, attached by a wide base to the left atrium wall, exhibiting variable densities. Computerized tomography identified a heterodense mass (53 × 46 × 37 mm) with similar attachments. Angiography showed two branches from the circumflex artery intricately associated with the mass. Despite unsuccessful embolization of the mass’ blood supply, surgical intervention including mitral valve replacement, tricuspid valve annuloplasty, and tumor removal was pursued. Pathohistological analysis confirmed the mass as a thrombus. During the postoperative follow-up, the patient presented with no complaints. Follow-up echocardiography indicated the normal function of the mechanical mitral valve prosthesis and the absence of intracardiac masses. While it remains unknown whether this neovascularization is specific to patients with severe mitral valve disease, this case highlights the diagnostic challenges of differentiating between thrombi and tumors in the context of mitral valve disease. It illustrates the critical role of multimodal imaging in elucidating the anatomical and functional relationships within the heart, thereby guiding accurate diagnosis and effective treatment. Full article
Show Figures

Figure 1

11 pages, 1395 KB  
Article
Aortic Valve Repair with External Annuloplasty in Bicuspid versus Tricuspid Aortic Valve Patients
by Davor Baric, Nikola Sliskovic, Gloria Sestan, Savica Gjorgjievska, Daniel Unic, Marko Kusurin, Josip Varvodic, Zrinka Safaric Oremus, Ivana Jurin, Nikola Bulj, Dubravka Susnjar and Igor Rudez
J. Cardiovasc. Dev. Dis. 2024, 11(1), 17; https://doi.org/10.3390/jcdd11010017 - 6 Jan 2024
Viewed by 3024
Abstract
Surgical repair for regurgitant bicuspid aortic valve (BAV) is promising but underutilized due to perceived complexities and lack of long-term data. This study evaluated the efficacy of valve-sparing root remodeling (VSRR) or isolated valve repair combined with calibrated external ring annuloplasty in BAV [...] Read more.
Surgical repair for regurgitant bicuspid aortic valve (BAV) is promising but underutilized due to perceived complexities and lack of long-term data. This study evaluated the efficacy of valve-sparing root remodeling (VSRR) or isolated valve repair combined with calibrated external ring annuloplasty in BAV versus tricuspid aortic valve (TAV) patients. All patients operated on for aortic regurgitation and/or aneurysm at our institution between 2014 and 2022 were included and entered into the Aortic Valve Insufficiency and ascending aorta Aneurysm InternATiOnal Registry (AVIATOR). Patients with successful repair at index surgery (100% in the BAV group, 93% in the TAV group, p = 0.044) were included in a systemic follow-up with echocardiography at regular intervals. Among 132 patients, 58 were in the BAV (44%) and 74 in the TAV group (56%). There were no inter-group differences in preoperative patient characteristics, except BAV patients being significantly younger (47 ± 18 y vs. 60 ± 14 y, p < 0.001) and having narrower aortic roots at the level of sinuses (41 ± 6 mm vs. 46 ± 13 mm, p < 0.001) and sinotubular junctions (39 ± 10 mm vs. 42 ± 11, p = 0.032). No perioperative deaths were recorded. At four years, there was no significant difference in terms of overall survival (96.3% BAV vs. 97.2% TAV, p = 0.373), freedom from valve reintervention (85.2% BAV vs. 93.4% TAV, p = 0.905), and freedom from severe aortic regurgitation (94.1% BAV vs. 82.9% TAV, p = 0.222). Surgical repair of BAV combined with extra-aortic annuloplasty can be performed with low perioperative morbidity and mortality and excellent mid-term results which are comparable to TAV repair. Full article
Show Figures

Figure 1

8 pages, 1618 KB  
Case Report
Transapical Mitral Valve-in-Ring Replacement Using the Innovative System under 3-Dimensional Printing Guidance
by Yiwei Wang, Yu Mao, Mengen Zhai, Yanyan Ma, Lanlan Li, Yang Liu and Jian Yang
J. Cardiovasc. Dev. Dis. 2023, 10(8), 339; https://doi.org/10.3390/jcdd10080339 - 7 Aug 2023
Cited by 1 | Viewed by 2584
Abstract
Background: Transcatheter mitral valve-in-ring replacement (TMViR) is an emerging alternative for patients with recurrent mitral regurgitation (MR) after a prior failed annuloplasty ring. However, intraoperative common issues and complications remain to be addressed. Case summary: We describe the case of a 67-year-old male [...] Read more.
Background: Transcatheter mitral valve-in-ring replacement (TMViR) is an emerging alternative for patients with recurrent mitral regurgitation (MR) after a prior failed annuloplasty ring. However, intraoperative common issues and complications remain to be addressed. Case summary: We describe the case of a 67-year-old male patient who underwent surgical mitral concomitant tricuspid annuloplasty repair 7 years ago who developed recurrent severe MR (New York Heart Association functional class IV). To avoid a high-risk surgical reoperation, we chose to perform a TMViR using an innovative dedicated device—the Mi-thos system—via a transapical approach. A patient-specific, 3-dimensional printed model was used to guide the procedure to avoid potential challenges. The procedure was performed successfully, and the patient exhibited symptomatic improvement. Conclusions: This case report highlights the first use of the innovative Mi-thos system in a TMViR procedure. The findings demonstrate the feasibility and safety of utilizing the Mi-thos system, guided by 3-dimensional printing technology, for patients who have experienced recurrent mitral regurgitation MR following a failed annuloplasty ring. Full article
Show Figures

Figure 1

12 pages, 4170 KB  
Review
Real-Time Monitoring and Step-by-Step Guidance for Transcatheter Tricuspid Annuloplasty Using Transesophageal Echocardiography
by Yu Liu, Wei Li, Daxin Zhou, Xiaochun Zhang, Dehong Kong, Zhenyi Ge, Haiyan Chen, Xianhong Shu, Cuizhen Pan and Junbo Ge
J. Cardiovasc. Dev. Dis. 2022, 9(12), 415; https://doi.org/10.3390/jcdd9120415 - 25 Nov 2022
Cited by 6 | Viewed by 3073
Abstract
Transcatheter tricuspid valve intervention (TTVI) is a novel alternative to functional tricuspid regurgitation (FTR) for patients with prohibitive surgical risk. Devices have been designed according to different pathophysiological mechanisms of FTR, including ones to achieve an edge-to-edge repair and others aiming at direct [...] Read more.
Transcatheter tricuspid valve intervention (TTVI) is a novel alternative to functional tricuspid regurgitation (FTR) for patients with prohibitive surgical risk. Devices have been designed according to different pathophysiological mechanisms of FTR, including ones to achieve an edge-to-edge repair and others aiming at direct annuloplasty. Recently, a transcatheter tricuspid valve repair system mimicking a surgical Kay procedure (K-Clip™ system, Huihe Medical Technology, Shanghai, China) completed its salvage-use trial. The system, which clips the posterior annulus to achieve bicuspidization of the TV, demonstrated acceptable procedural safety and efficacy. Each TTVI system has distinct characteristics for echocardiographic imaging and special consideration for intraoperative guidance. This review focuses on elaborating how two-dimensional and three-dimensional transesophageal echocardiography (TEE) are used in clinical practice to guide K-Clip™ implantation in comparison to other direct annular reduction devices. A limited number of TEE work planes are proposed for the procedure with the aim to provide a steeper learning curve for the echocardiographer and interventionalist while simplifying the implantation steps. Full article
(This article belongs to the Special Issue Cardiac Imaging in Valvular Heart Disease)
Show Figures

Figure 1

11 pages, 1389 KB  
Article
Results after Repair of Functional Tricuspid Regurgitation with a Three-Dimensional Annuloplasty Ring
by Elda Dzilic, Thomas Guenther, Amel Bouziani, Bernhard Voss, Stephanie Voss, Keti Vitanova, Markus Krane and Ruediger Lange
J. Clin. Med. 2021, 10(21), 5080; https://doi.org/10.3390/jcm10215080 - 29 Oct 2021
Cited by 2 | Viewed by 2968
Abstract
Background: Tricuspid valve (TV) repair is the recommended treatment for severe functional tricuspid regurgitation (fTR) in patients undergoing left-sided surgery. For this purpose, a wide range of annuloplasty devices differing in form and flexibility are available. This study reports the results using a [...] Read more.
Background: Tricuspid valve (TV) repair is the recommended treatment for severe functional tricuspid regurgitation (fTR) in patients undergoing left-sided surgery. For this purpose, a wide range of annuloplasty devices differing in form and flexibility are available. This study reports the results using a three-dimensional annuloplasty ring (Medtronic, Contour 3D Ring) for TV repair and analysis of risk factors. Methods: A cohort of 468 patients who underwent TV repair (TVr) with a concomitant cardiac procedure from December 2010 to January 2017 was retrospectively analyzed. Results: At follow-up, 96.1% of patients had no/trivial or mild TR. The 30-day mortality was 4.7%; it significantly differed between electively performed operations (2.7%) and urgent/emergent operations (11.7%). Risk factors for recurrent moderate and severe TR were LVEF < 50%, TAPSE < 16 mm, and moderate mitral valve (MV) regurgitation at follow-up. Preoperatively reduced renal function lead to a higher 30-day and overall mortality. Reoperation of the TV was required in six patients (1.6%). Risk factors for TV related reoperations were preoperative TV annulus over 50 mm and an implanted permanent pacemaker. Conclusions: TVr with the Contour 3D annuloplasty ring shows low TR recurrence and reoperation rates. Risk-factor analysis for the recurrence of TR revealed the importance of left- and right-ventricular function. Full article
Show Figures

Figure 1

13 pages, 1285 KB  
Review
A Meta-Analysis on Prophylactic Donor Heart Tricuspid Annuloplasty in Orthotopic Heart Transplantation: High Hopes from a Small Intervention
by Alberto Emanuel Bacusca, Andrei Tarus, Alexandru Burlacu, Mihail Enache and Grigore Tinica
Healthcare 2021, 9(3), 306; https://doi.org/10.3390/healthcare9030306 - 10 Mar 2021
Cited by 6 | Viewed by 2602
Abstract
(1) Background: Tricuspid regurgitation (TR) is the most frequent valvulopathy in heart transplant recipients (HTX). We aimed to assess the influence of prophylactic donor heart tricuspid annuloplasty (TA) in orthotopic HTX (HTX-A), comparing the outcomes with those of HTX patients. (2) Methods: Electronic [...] Read more.
(1) Background: Tricuspid regurgitation (TR) is the most frequent valvulopathy in heart transplant recipients (HTX). We aimed to assess the influence of prophylactic donor heart tricuspid annuloplasty (TA) in orthotopic HTX (HTX-A), comparing the outcomes with those of HTX patients. (2) Methods: Electronic databases of PubMed, EMBASE, and SCOPUS were searched. The endpoints were as follows: the overall rate of postprocedural TR (immediate, one week, six months, and one year after the procedure), postoperative complications (permanent pacemaker implantation rate, bleeding), redo surgery for TR, and mortality. (3) Results: This meta-analysis included seven studies. Immediate postprocedural, one-week, six-month and one-year tricuspid insufficiency rates were significantly lower in the HTX-A group. There was no difference in permanent pacemaker implantation rate between the groups. The incidence of postoperative bleeding was similar in both arms. The rate of redo surgery for severe TR was reported only by two authors. In both publications, the total number of events was higher in the HTX cohort, meanwhile pooled effect analysis showed no difference among the intervention and control groups. Mortality at one year was similar in both arms. (4) Conclusion: Our study showed that donor heart TA reduces TR incidence in the first year after orthotopic heart transplantation without increasing the surgical complexity. This is a potentially important issue, given the demand for heart transplants and the need to optimize outcomes when this resource is scarce. Full article
(This article belongs to the Special Issue Perioperative Care)
Show Figures

Figure 1

Back to TopTop