Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = turkey tarsometatarsus model

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 5071 KB  
Article
Comparative Biomechanical Analysis of Kirschner Wire Fixation in Dorsally Displaced Distal Radius Fractures
by Awad Dmour, Ștefan-Lucian Toma, Alin-Marian Cazac, Stefan Dragos Tirnovanu, Nicoleta Dima, Bianca-Ana Dmour, Dragos Cristian Popescu and Ovidiu Alexa
Life 2024, 14(12), 1684; https://doi.org/10.3390/life14121684 - 19 Dec 2024
Viewed by 1836
Abstract
Objective: This study aims to evaluate and compare the biomechanical performance of two Kirschner (K) wire configurations—the intra-focal and interfragmentary techniques—for the fixation of dorsally displaced distal radius fractures. The study also assesses the impact of K-wire diameter (1.6 mm vs. 2.0 mm) [...] Read more.
Objective: This study aims to evaluate and compare the biomechanical performance of two Kirschner (K) wire configurations—the intra-focal and interfragmentary techniques—for the fixation of dorsally displaced distal radius fractures. The study also assesses the impact of K-wire diameter (1.6 mm vs. 2.0 mm) on mechanical stability. Methods: Sixty fresh turkey tarsometatarsus bones were selected and divided into four groups based on the K-wire configuration and diameter used. Fractures were created at standardized locations, and each bone was stabilized using either the intra-focal also known as modified Kapandji (Ka) or interfragmentary technique. Mechanical testing, including axial compression and flexion tests, was performed to assess the biomechanical stability of each configuration. Results: The interfragmentary configuration consistently demonstrated superior biomechanical performance compared to the intra-focal technique. Specifically, the use of 2.0 mm K-wires resulted in significantly higher axial stiffness (13.28 MPa) and load at break (3070 N) compared to the 1.5 mm wires. Confidence intervals further supported the robustness of these findings. The interfragmentary technique, especially with thicker K-wires, provided greater load-bearing capacity and stiffness. Conclusion: The interfragmentary technique with 2.0 mm K-wires offers superior mechanical stability compared to the intra-focal technique, making it the preferred choice for stabilizing comminuted extra-articular distal radius fractures. These findings suggest that adopting this technique may reduce the risk of postoperative complications such as fracture displacement or malunion. Further research involving osteoporotic bone models and clinical trials is recommended to validate these findings in real-world settings. Full article
(This article belongs to the Section Medical Research)
Show Figures

Figure 1

Back to TopTop