Search Results (6)

Search Parameters:
Keywords = upper-arm photoplethysmography (upper-arm PPG)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
21 pages, 3267 KB  
Article
Impact of Anatomical Placement on the Accuracy of Wearable Heart Rate Monitors During Rest and Various Exercise Intensities
by Masoud Moghaddam, James P. Collins, Caroline E. Gardner and Michael C. Rabel
Sensors 2026, 26(1), 176; https://doi.org/10.3390/s26010176 - 26 Dec 2025
Cited by 2 | Viewed by 3310
Abstract
Purpose: This study evaluated the accuracy of arm-based photoplethysmography (PPG) wearable heart rate (HR) monitors in comparison to a validated chest strap reference across various activity levels. Methods: Twenty-eight healthy adults (14 males, 14 females; aged 23.8 ± 1.1 years) wore six HR [...] Read more.
Purpose: This study evaluated the accuracy of arm-based photoplethysmography (PPG) wearable heart rate (HR) monitors in comparison to a validated chest strap reference across various activity levels. Methods: Twenty-eight healthy adults (14 males, 14 females; aged 23.8 ± 1.1 years) wore six HR monitors: Polar H10 chest strap, Polar Verity Sense on the forearm, Garmin Forerunner on the wrist, and three identical Whoop 4.0 devices placed on the left wrist, forearm, and upper arm. Participants completed rest, warm-up, high-intensity burpees, and graded treadmill exercise. HR data were analyzed using mean absolute percentage error (MAPE), Bland–Altman analysis, concordance correlation coefficient (CCC), and Deming regression. Results: Accuracy was highest at rest and gradually decreased as movement intensity increased. During rest, all devices showed minimal bias and high agreement (CCC > 0.99), with Verity Sense recording the lowest MAPE. In warm-up, Whoop-upper arm and Verity Sense outperformed wrist and Garmin positions, while the Whoop-forearm showed proportional and systematic bias. Burpees resulted in the lowest accuracy across devices (CCC < 0.50), but Whoop-upper arm performed better than other placements. During the Modified Bruce protocol, Verity Sense and Whoop-upper arm had the strongest agreement with the chest strap. Placement of identical Whoop units affected accuracy, with the upper arm outperforming forearm and wrist positions. Conclusions: PPG wearables provided accurate HR monitoring at rest, during warm-up, and during steady-state graded exercise, particularly when positioned proximally (forearm or upper arm). Accuracy declined during short, high-intensity, full-body activities due to motion artifacts. Both the forearm-mounted Verity Sense and the upper-arm Whoop demonstrated the closest agreement with the chest-strap reference. The intra-device comparison of identical Whoop units confirmed that anatomical placement alone significantly affects accuracy. Full article
(This article belongs to the Section Wearables)
Show Figures

Figure 1

15 pages, 2400 KB  
Article
Robust Prediction of Cardiorespiratory Signals from a Multimodal Physiological System on the Upper Arm
by Kimberly L. Branan, Rachel Kurian, Justin P. McMurray, Madhav Erraguntla, Ricardo Gutierrez-Osuna and Gerard L. Coté
Biosensors 2025, 15(8), 493; https://doi.org/10.3390/bios15080493 - 1 Aug 2025
Cited by 1 | Viewed by 1431
Abstract
Many commercial wearable sensor systems typically rely on a single continuous cardiorespiratory sensing modality, photoplethysmography (PPG), which suffers from inherent biases (i.e., differences in skin tone) and noise (e.g., motion and pressure artifacts). In this research, we present a wearable device that provides [...] Read more.
Many commercial wearable sensor systems typically rely on a single continuous cardiorespiratory sensing modality, photoplethysmography (PPG), which suffers from inherent biases (i.e., differences in skin tone) and noise (e.g., motion and pressure artifacts). In this research, we present a wearable device that provides robust estimates of cardiorespiratory variables by combining three physiological signals from the upper arm: multiwavelength PPG, single-sided electrocardiography (SS-ECG), and bioimpedance plethysmography (BioZ), along with an inertial measurement unit (IMU) providing 3-axis accelerometry and gyroscope information. We evaluated the multimodal device on 16 subjects by its ability to estimate heart rate (HR) and breathing rate (BR) in the presence of various static and dynamic noise sources (e.g., skin tone and motion). We proposed a hierarchical approach that considers the subject’s skin tone and signal quality to select the optimal sensing modality for estimating HR and BR. Our results indicate that, when estimating HR, there is a trade-off between accuracy and robustness, with SS-ECG providing the highest accuracy (low mean absolute error; MAE) but low reliability (higher rates of sensor failure), and PPG/BioZ having lower accuracy but higher reliability. When estimating BR, we find that fusing estimates from multiple modalities via ensemble bagged tree regression outperforms single-modality estimates. These results indicate that multimodal approaches to cardiorespiratory monitoring can overcome the accuracy–robustness trade-off that occurs when using single-modality approaches. Full article
(This article belongs to the Special Issue Wearable Biosensors for Health Monitoring)
Show Figures

Figure 1

22 pages, 3610 KB  
Article
Benchmarking of Sensor Configurations and Measurement Sites for Out-of-the-Lab Photoplethysmography
by Max Nobre Supelnic, Afonso Fortes Ferreira, Patrícia Justo Bota, Luís Brás-Rosário and Hugo Plácido da Silva
Sensors 2024, 24(1), 214; https://doi.org/10.3390/s24010214 - 29 Dec 2023
Cited by 3 | Viewed by 4134
Abstract
Photoplethysmography (PPG) is used for heart-rate monitoring in a variety of contexts and applications due to its versatility and simplicity. These applications, namely studies involving PPG data acquisition during day-to-day activities, require reliable and continuous measurements, which are often performed at the index [...] Read more.
Photoplethysmography (PPG) is used for heart-rate monitoring in a variety of contexts and applications due to its versatility and simplicity. These applications, namely studies involving PPG data acquisition during day-to-day activities, require reliable and continuous measurements, which are often performed at the index finger or wrist. However, some PPG sensors are susceptible to saturation, motion artifacts, and discomfort upon their use. In this paper, an off-the-shelf PPG sensor was benchmarked and modified to improve signal saturation. Moreover, this paper explores the feasibility of using an optimized sensor in the lower limb as an alternative measurement site. Data were collected from 28 subjects with ages ranging from 18 to 59 years. To validate the sensors’ performance, signal saturation and quality, wave morphology, performance of automatic systolic peak detection, and heart-rate estimation, were compared. For the upper and lower limb locations, the index finger and the first toe were used as reference locations, respectively. Lowering the amplification stage of the PPG sensor resulted in a significant reduction in signal saturation, from 18% to 0.5%. Systolic peak detection at rest using an automatic algorithm showed a sensitivity and precision of 0.99 each. The posterior wrist and upper arm showed pulse wave morphology correlations of 0.93 and 0.92, respectively. For these locations, peak detection sensitivity and precision were 0.95, 0.94 and 0.89, 0.89, respectively. Overall, the adjusted PPG sensors are a good alternative for obtaining high-quality signals at the fingertips, and for new measurement sites, the posterior pulse and the upper arm allow for high-quality signal extraction. Full article
Show Figures

Figure 1

19 pages, 7968 KB  
Article
Upper-Arm Photoplethysmographic Sensor with One-Time Calibration for Long-Term Blood Pressure Monitoring
by Ching-Fu Wang, Ting-Yun Wang, Pei-Hsin Kuo, Han-Lin Wang, Shih-Zhang Li, Chia-Ming Lin, Shih-Chieh Chan, Tzu-Yu Liu, Yu-Chun Lo, Sheng-Huang Lin and You-Yin Chen
Biosensors 2023, 13(3), 321; https://doi.org/10.3390/bios13030321 - 25 Feb 2023
Cited by 20 | Viewed by 8159
Abstract
Wearable cuffless photoplethysmographic blood pressure monitors have garnered widespread attention in recent years; however, the long-term performance values of these devices are questionable. Most cuffless blood pressure monitors require initial baseline calibration and regular recalibrations with a cuffed blood pressure monitor to ensure [...] Read more.
Wearable cuffless photoplethysmographic blood pressure monitors have garnered widespread attention in recent years; however, the long-term performance values of these devices are questionable. Most cuffless blood pressure monitors require initial baseline calibration and regular recalibrations with a cuffed blood pressure monitor to ensure accurate blood pressure estimation, and their estimation accuracy may vary over time if left uncalibrated. Therefore, this study assessed the accuracy and long-term performance of an upper-arm, cuffless photoplethysmographic blood pressure monitor according to the ISO 81060-2 standard. This device was based on a nonlinear machine-learning model architecture with a fine-tuning optimized method. The blood pressure measurement protocol followed a validation procedure according to the standard, with an additional four weekly blood pressure measurements over a 1-month period, to assess the long-term performance values of the upper-arm, cuffless photoplethysmographic blood pressure monitor. The results showed that the photoplethysmographic signals obtained from the upper arm had better qualities when compared with those measured from the wrist. When compared with the cuffed blood pressure monitor, the means ± standard deviations of the difference in BP at week 1 (baseline) were −1.36 ± 7.24 and −2.11 ± 5.71 mmHg for systolic and diastolic blood pressure, respectively, which met the first criterion of ≤5 ± ≤8.0 mmHg and met the second criterion of a systolic blood pressure ≤ 6.89 mmHg and a diastolic blood pressure ≤ 6.84 mmHg. The differences in the uncalibrated blood pressure values between the test and reference blood pressure monitors measured from week 2 to week 5 remained stable and met both criteria 1 and 2 of the ISO 81060-2 standard. The upper-arm, cuffless photoplethysmographic blood pressure monitor in this study generated high-quality photoplethysmographic signals with satisfactory accuracy at both initial calibration and 1-month follow-ups. This device could be a convenient and practical tool to continuously measure blood pressure over long periods of time. Full article
Show Figures

Figure 1

13 pages, 778 KB  
Article
PPG2EMG: Estimating Upper-Arm Muscle Activities and EMG from Wrist PPG Values
by Masahiro Okamoto and Kazuya Murao
Sensors 2023, 23(4), 1782; https://doi.org/10.3390/s23041782 - 5 Feb 2023
Cited by 8 | Viewed by 6416
Abstract
The electromyogram (EMG) is a waveform representation of the action potential generated by muscle cells using electrodes. EMG acquired using surface electrodes is called surface EMG (sEMG), and it is the acquisition of muscle action potentials transmitted by volume conduction from the skin. [...] Read more.
The electromyogram (EMG) is a waveform representation of the action potential generated by muscle cells using electrodes. EMG acquired using surface electrodes is called surface EMG (sEMG), and it is the acquisition of muscle action potentials transmitted by volume conduction from the skin. Surface electrodes require disposable conductive gel or adhesive tape to be attached to the skin, which is costly to run, and the tape is hard on the skin when it is removed. Muscle activity can be evaluated by acquiring muscle potentials and analyzing quantitative, temporal, and frequency factors. It is also possible to evaluate muscle fatigue because the frequency of the EMG becomes lower as the muscle becomes fatigued. Research on human activity recognition from EMG signals has been actively conducted and applied to systems that support arm and hand functions. This paper proposes a method for recognizing the muscle activity state of the arm using pulse wave data (PPG: Photoplethysmography) and a method for estimating EMG using pulse wave data. This paper assumes that the PPG sensor is worn on the user’s wrist to measure the heart rate. The user also attaches an elastic band to the upper arm, and when the user exerts a force on the arm, the muscles of the upper arm contract. The arteries are then constricted, and the pulse wave measured at the wrist becomes weak. From the change in the pulse wave, the muscle activity of the arm can be recognized and the number of action potentials of the muscle can be estimated. From the evaluation experiment with five subjects, three types of muscle activity were recognized with 80+%, and EMG was estimated with approximately 20% error rate. Full article
Show Figures

Figure 1

9 pages, 208 KB  
Article
A Prospective Evaluation of Duplex Ultrasound for Thoracic Outlet Syndrome in High-Performance Musicians Playing Bowed String Instruments
by Garret Adam, Kevin Wang, Christopher J. Demaree, Jenny S. Jiang, Mathew Cheung, Carlos F. Bechara and Peter H. Lin
Diagnostics 2018, 8(1), 11; https://doi.org/10.3390/diagnostics8010011 - 25 Jan 2018
Cited by 26 | Viewed by 8563
Abstract
Thoracic outlet syndrome (TOS) is a neurovascular condition involving the upper extremity, which is known to occur in individuals who perform chronic repetitive upper extremity activities. We prospectively evaluate the incidence of TOS in high-performance musicians who played bowed string musicians. Sixty-four high-performance [...] Read more.
Thoracic outlet syndrome (TOS) is a neurovascular condition involving the upper extremity, which is known to occur in individuals who perform chronic repetitive upper extremity activities. We prospectively evaluate the incidence of TOS in high-performance musicians who played bowed string musicians. Sixty-four high-performance string instrument musicians from orchestras and professional musical bands were included in the study. Fifty-two healthy volunteers formed an age-matched control group. Bilateral upper extremity duplex scanning for subclavian vessel compression was performed in all subjects. Provocative maneuvers including Elevated Arm Stress Test (EAST) and Upper Limb Tension Test (ULTT) were performed. Abnormal ultrasound finding is defined by greater than 50% subclavian vessel compression with arm abduction, diminished venous waveforms, or arterial photoplethysmography (PPG) tracing with arm abduction. Bowed string instruments performed by musicians in our study included violin (41%), viola (33%), and cello (27%). Positive EAST or ULTT test in the musician group and control group were 44%, and 3%, respectively (p = 0.03). Abnormal ultrasound scan with vascular compression was detected in 69% of musicians, in contrast to 15% of control subjects (p = 0.03). TOS is a common phenomenon among high-performance bowed string instrumentalists. Musicians who perform bowed string instruments should be aware of this condition and its associated musculoskeletal symptoms. Full article
(This article belongs to the Special Issue Diagnosis and Treatment of Thoracic Outlet Syndrome)